Attachment L - VOL4_1363603dwg3of9.pdf
PDF 6 MB Posted
- Attached to
- P475 Aircraft Maintenance Hangar
- Solicitation number
- N4008526R0148
About this file
These structural drawings detail the design for a precast concrete parking garage for a Naval Facilities Engineering Systems Command (NAVFAC) project at MCAS Beaufort, South Carolina. The multi-level parking structure will be constructed using precast concrete elements, including pile foundations, grade beams, columns, wall panels, double tee floor systems, and spandrel beams. The structural design follows the 2018 International Building Code and incorporates specific engineering requirements for seismic design category D, with a design base shear of 1,809 kips and a seismic response coefficient of 0.087g.
Key technical specifications include 14-inch square precast, prestressed concrete pile foundations driven to a tip elevation of -50 feet, concrete strength ranging from 4,000 to 7,000 PSI, and reinforcing steel conforming to ASTM A615 Grade 60 standards. The structure is designed to withstand wind loads up to 139 MPH and snow loads of 5 PSF. The project includes provisions for potential future photovoltaic panel installation, with the precast concrete structure engineered to support an aluminum canopy system. The structural design was prepared by Speight Marshall Francis, with the contract modification dates indicating work spanning from May 2023 to October 2025.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES:
THE STRUCTURAL DRAWINGS MUST BE USED IN CONJUNCTION WITH THE
ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS
AND THE SPECIFICATIONS. THE CONTRACTOR MUST VERIFY THE REQUIREMENTS
OF OTHER TRADES FOR ITEMS TO BE PLACED OR SET IN THE STRUCTURAL
WORK.
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE PROVISIONS
OF THE INTERNATIONAL BUILDING CODE, 2018 EDITION, AS ADOPTED BY THE
UNIFIED FACILITIES CRITERIA, AND AS FOLLOWS:
BUILDINGS, DECEMBER 8, 2018 WITH CHANGE 1,
THE WORK UNDER THE FOLLOWING SPECIFICATION SECTIONS IS SUBJECT TO
SPECIAL INSPECTIONS AND TESTS AS DESCRIBED IN SECTION 1704 OF THE
INTERNATIONAL BUILDING CODE, 2018 EDITION:
033000 - CAST-IN-PLACE CONCRETE
033433 - PRECAST PRESTRESSED STRUCTURAL CONCRETE
042000 - UNIT MASONRY
051200 - STRUCTURAL STEEL
053000 - STEEL DECK
054000 - COLD-FORMED METAL FRAMING
THE CONTRACTOR MUST BE RESPONSIBLE FOR TEMPORARY SHORING AND
BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER
ALIGNMENT UNTIL PERMANENT SUPPORTS AND LATERAL BRACING ARE IN PLACE.
SPECIFIC NOTES AND DETAILS ON THE DRAWINGS MUST TAKE PRECEDENCE
OVER THE STRUCTURAL NOTES AND TYPICAL DETAILS.
CONSULTANTS' DRAWINGS, INCLUDING THE STRUCTURAL DRAWINGS, ARE
CONSIDERED SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. ANY
OMISSIONS OR CONFLICTS, INCLUDING DIMENSIONS, BETWEEN VARIOUS
ELEMENTS OF THE CONSULTANTS' DRAWINGS AND/OR SPECIFICATIONS MUST BE
BROUGHT TO THE ATTENTION OF THE ARCHITECT CONTRACTING OFFICER PRIOR
TO PROCEEDING WITH THE WORK.
THE STRUCTURAL DOCUMENTS MUST NOT BE REPRODUCED, OR COPIED IN WHOLE
OR IN PART BY THE CONTRACTOR OR SUBCONTRACTORS FOR PREPARATION OF
SHOP DRAWINGS OR OTHER SUBMITTALS WITHOUT WRITTEN PERMISSION FROM
THE ARCHITECT CONTRACTING OFFICER.
LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE AS FOLLOWS:
LIVE LOADS:
SNOW DESIGN DATA:
WIND DESIGN DATA:
SEISMIC DESIGN DATA:
ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE
BASIC SEISMIC-FORCE-RESISTING SYSTEM IS SPECIAL REINFORCED
CONCRETE SHEAR WALLS
NO MECHANICAL UNITS HAVE BEEN CONSIDERED IN THE STRUCTURAL DESIGN.
SUBMIT LOCATION, DIMENSIONS AND OPERATING WEIGHTS OF ANY UNITS
WEIGHING MORE THAN 100 POUNDS TO THE STRUCTURAL ENGINEER FOR
REVIEW, PRIOR TO PLACEMENT.
DRIVEN PILE NOTES:
PILING MUST COMPLY WITH PRECAST CONCRETE INSTITUTE MNL-116 AND
SECTIONS 1808 AND 1810 OF THE 2018 INTERNATIONAL BUILDING CODE. PILING
MUST BE 14 INCH SQUARE PRECAST, PRESTRESSED CONCRETE SECTIONS.
PILE FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE
RECOMMENDATIONS IN THE GEOTECHNICAL EXPLORATION REPORT PREPARED
BY TERRACON CONSULTANTS, INC. DATED DECEMBER 14, 2020.
BASE BID LENGTH ON DRIVING ALL PILES, EXCEPT TEST PILES, TO AN ACTUAL
TIP ELEVATION PF -50 FEET.
THE CONTRACTOR MUST DRIVE 6 - 85 FOOT LONG TEST PILES IN LOCATIONS
SHOWN ON THE FOUNDATION PLAN. TEST PILE LOCATOINS MAY BE RELOCATED
IN ADDITION TO PDA TESTING, CONDUCT STATIC LOAD TESTS ON ONE OF THE TEST
PILES PER THE SPECIFICATIONS.
THE GENERAL CONTRACTOR MUST PROVIDE AN AS-INSTALLED PILE DRAWING
FOR EACH PILE WITH PILE LOCATION DISCREPANCIES NOTED ON THE DRAWINGS.
PILING MUST BE DRIVEN TO A MAXIMUM TOLERANCE IN ANY DIRECTION OF THREE
INCHES PER PILE. WHERE AN INDIVIDUAL PILE IS DRIVEN OUT OF POSITION MORE
THAN THREE INCHES IN ANY DIRECTION AND/OR WHERE THE CENTER OF
GRAVITY OF A PILE GROUP IS OUT OF POSITION MORE THAN TWO INCHES, THE
CONTRACTOR MAY BE REQUIRED TO DRIVE AN ADDITONAL PILE OR PILES TO
COMPENSATE FOR THE ECCENTRICITY OF THE PILE AND/OR PILE GROUP.
CAST-IN-PLACE CONCRETE NOTES:
CAST-IN-PLACE CONCRETE HAS BEEN DESIGNED IN ACCORDANCE WITH THE
AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE REQUIREMENTS FOR
STRUCTURAL CONCRETE (ACI 318-14) AND COMMENTARY (ACI 318R-14)".
CONCRETE MUST BE NORMAL WEIGHT AND MUST OBTAIN 28 DAY COMPRESSIVE
STRENGTHS AS FOLLOWS:
REINFORCING MATERIALS MUST BE AS FOLLOWS:
REINFORCING BARS - ASTM A615, GRADE 60, DEFORMED
ALTERNATIVELY, USE GRADE 40 FOR TIES AND STIRRUPS
ALL REINFORCING STEEL AND EMBEDDED ITEMS MUST BE ACCURATELY PLACED
IN THE POSITIONS SHOWN AND ADEQUATELY TIED AND SUPPORTED BEFORE
CONCRETE IS PLACED TO PREVENT DISPLACEMENT BEYOND PERMITTED
TOLERANCES.
MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS INDICATED ON THE
DRAWINGS MUST GOVERN WHEN IN CONFLICT WITH ACI 318-14 TABLE 20.6.1.3.1.
UNLESS OTHERWISE NOTED ON THE STRUCTURAL DRAWINGS:
LAP SPLICE LENGTHS MUST COMPLY WITH 'CAST-IN-PLACE CONCRETE
REINFORCING BAR LAP SPLICE SCHEDULE' ON SHEET PSB003
USE TENSION BAR LAP SPLICE LENGTHS
SPLICES MAY BE MADE WITH MECHANICAL SPLICES (AT CONTRACTOR'S
OPTION). MECHANICAL SPLICES MUST BE:
CAPABLE OF RESISTING 125% OF THE TENSION CAPACITY
POSITIVE-CONNECTING TYPE COUPLERS
SUBMITTED FOR REVIEW
STAGGERED A MINIMUM OF 24" ALONG THE LONGITUDINAL
AXIS OF ADJACENT BARS
STRUCTURAL PRECAST CONCRETE NOTES:
STRUCTURAL PRECAST CONCRETE MUST BE DESIGNED IN ACCORDANCE WITH
THE AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE REQUIREMENTS FOR
REINFORCED CONCRETE" ACI 318-14.
THE CONTRACTOR MUST SUBMIT SHOP DRAWINGS PREPARED BY A REGISTERED
PROFESSIONAL ENGINEER FOR THE DESIGN OF STRUCTURAL PRECAST CONCRETE,
INCLUDING DESIGN LOADING AND REACTIONS APPLIED TO THE SUPPORTING
STRUCTURE.
CONNECTION DETAILS SHOWN ARE SCHEMATIC ONLY. ALL CONNECTIONS MUST
BE DEVELOPED BY THE PRECAST MANUFACTURER TO SUIT THE SPECIFIED
LOADS AND CONNECTIONS MUST ACCOUNT FOR THERMAL MOVEMENT AND
CREEP OF PRECAST MEMBERS. DETAIL ALL CONNECTIONS ON SHOP DRAWINGS.
IN ADDITION TO THEIR OWN DEAD WEIGHT AND THE DEAD LOADS SHOWN,
PRECAST MEMBERS MUST BE DESIGNED TO SUPPORT THE LIVE LOADS
INDICATED IN THE GENERAL NOTES.
CONCRETE MUST BE NORMAL WEIGHT AND MUST OBTAIN A 28 DAY
COMPRESSIVE STRENGTH OF 5,000 PSI.
REINFORCING MATERIALS MUST BE AS FOLLOWS:
REINFORCING BARS: ASTM A615, GRADE 60, DEFORMED
ALTERNATIVELY, USE GRADE 40 FOR TIES AND STIRRUPS
WELDED WIRE REINFORCEMENT: ASTM A185
PRESTRESSING TENDONS MUST COMPLY WITH ASTM A416 GRADE 270,
UNCOATED, 7-WIRE STRESS-RELIEVED STRAND.
STRUCTURAL SLAB-ON-GRADE 100 PSF
LOBBIES 100 PSF
STAIRWAYS 100 PSF
GARAGE PARKING LEVELS 40 PSF
ROOF (NON-PARKING) 20 PSF
GROUND SNOW LOAD 5 PSF
RAIN-ON-SNOW SURCHARGE LOAD 5 PSF
ULTIMATE DESIGN WIND SPEED 139 MPH
NOMINAL DESIGN WIND SPEED 108 MPH
RISK CATEGORY II
WIND EXPOSURE C
INTERNAL PRESSURE COEFFICIENT ±0.18
RISK CATEGORY II
SEISMIC IMPORTANCE FACTOR 1.0
SS (SITE SPECIFIC SDS VALUES)
S1 (SITE SPECIFIC SD1 VALUES)
SITE CLASS F
SDS 0.435g SD1 0.251g
SEISMIC DESIGN CATEGORY D
DESIGN BASE SHEAR 1,809 KIPS
SEISMIC RESPONSE COEFFICIENT 0.087g
RESPONSE MODIFICATION FACTOR 5
1.
2.
3.
4.
6.
7.
8.
9.
10.
A.
B.
C.
D.
E.
A.
B.
C.
D.
E.
F.
G.
I.
J.
A.
B.
C.
D.
1.
2.
3.
4.
5.
1.
2.
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
1.
2.
4.
5.
6.
7.
8.
9.
11.
1.
2.
3.
4.
5.
6.
A.
A.
B.
C.
1.
2.
3.
4.
OF THE SPLICED BAR
1.
2.
3.
4.
5.
6.
7.
A.
B.
GENERAL NOTES (CONTINUED):
FOUNDATION HAVE BEEN DESIGNED FOR THE LOADS SHOWN ON THE 'PRECAST
LOAD PLAN' ON SHEET PSB107. THE LOADS WERE CALCULATED BY SPEIGHT,
MARSHALL AND FRANCIS, P.C. BASED ON THE SYSTEM PRESENTED WITHIN
THESE DRAWINGS. IF THE ACTUAL LOADS VARY FROM THOSE INDICATED ON
SHEET PSB107, MODIFICATIONS TO THE FOUNDATION DESIGN MAY BE
NECESSARY. THE CONTRACTOR MUST PROVIDE ACTUAL LOADS (GRAVITY,
12.
SEISMIC AND WIND) TO THE ARCHITECT AS SOON AS POSSIBLE, SO THE
VERIFICATION OF THE FOUNDATION AS SHOWN HEREIN IS ADEQUATE.
CHANGE 1, OCTOBER 1, 2020
TO HEAVY LOADS, MARCH 1, 2005
AUGUST 1, 2020
THIS PROJECT IS SUBJECT TO IBC SPECIAL INSPECTION REQUIREMENTS AS
MODIFIED BY UFC 3-301-01. THE STATEMENT AND SCHEDULE OF SPECIAL
INSPECTIONS DEFINE THE SCOPE OF SPECIAL INSPECTIONS ARE INCLUDED
WITH THE PROJECT SPECIFICATIONS. SPECIAL INSPECTIONS FOR WIND
REQUIREMENTS AND SEISMIC RESISTANCE ARE NOT REQUIRED SINCE THE
NOMINAL WIND SPEED FOR THE PROJECT LOCATION DOES NOT EXCEED
110 MPH AND THE RISK CATEGORY IS II. STRUCTURAL OBSERVATIONS FOR
PROGRESSIVE COLLAPSE AVOIDANCE ARE NOT REQUIRED.
PILES SHOWN ON PLAN MUST BE TESTED IN USING PILE DRIVING ANALYZER
(PDA) TO MEASURE DRIVING STRESSES, EVALUATE HAMMER PERFORMANCE, AND
VERIFY CAPACITIES. THE TESTS MUST BE DONE IN ACCORDANCE WITH THE
SPECIFICATIONS AND UNDER THE DIRECTION OF THE GEOTECHNICAL ENGINEER.
EXISTING BUILDINGS ON THE SITE ARE PILE SUPPORTED AND GEOTHERMAL WELLS
EXIST BENEATH THE EXISTING PARKING LOTS. EXISTING PILES AND GEOTHERMAL
WELLS WILL REMAIN AND BE CUT OFF 2’-0” BELOW NEW BUILDING SLABS AND
FOUNDATIONS. NEW PILES MUST BE PLACED 14” CLEAR FROM THE EXISTING PILES
AND WELLS . THE EXACT LOCATION OF THE EXISTING PILES AND WELLS ARE UNKNOWN.
THE EXISTING PILES AND WELLS MUST BE EXPOSED AND LOCATED DURING CONSTRUCTION.
IN ORDER TO MAINTAIN THE 14” CLEARANCE BETWEEN NEW AND EXISTING, THE NEW PILES
MUST BE FIELD ADJUSTED DURING PILE INSTALLATION. THE PROCESS FOR THIS
FIELD ADJUSTMENT WILL BE TO UNCOVER THE EXISTING PILES AND WELLS.
SURVEY THE LOCATION OF THE PILES AND WELLS AND SUBMIT THE SURVEY TO
THE STRUCTURAL ENGINEER. THE STRUCTURAL ENGINEER WILL EVALUATE THE
REQUIRED LOCATION OF NEW PILES RELATIVE TO THE EXISTING PILES AND WELLS
AND PROVIDE DIRECTION TO THE CONTRACTOR ON WHERE TO DRIVE THE NEW PILES.
AFTER THE EVALUATION OF EXISTING CONDITIONS AND FOUNDATION REDESIGN,
THE STRUCTURAL ENGINEER WILL PROVIDE DIRECTION ON WHICH PILES NEED TO BE
RELOCATED. THE REVIEW AND REDESIGN TIME FOR EACH SURVEY SUBMITTAL IS 30 DAYS.
10.
052100 - STEEL JOIST FRAMING
H.
034100 - STRUCTURAL PRECAST CONCRETE
034500 - PRECAST ARCHITECTURAL CONCRETE
K.
312300.0020 - EXCAVATION AND FILL
316213.20 - PRECAST / PRESTRESSED CONCRETE PILE
UCF 1-200-01 DoD BUILDING CODE, OCTOBER 8, 2019 WITH
UCF 3-220-01 GEOTECHNICAL ENGINEERING, NOVEMBER 1, 2012
UFC 3-301-01 STRUCTURAL ENGINEERING, OCTOBER 1, 2019
UFC 3-320-06A CONCRETE FLOOR SLABS-ON-GRADE SUBJECTED
UFC 4-010-01 DoD MINIMUM ANTITERRORISM STANDARDS FOR
RAIN DESIGN DATAE.
100 YEAR (1 HOUR RAINFALL)1.
CONCRETE MUST BE NORMAL WEIGHT AND MUST OBTAIN 28 DAY COMPRESSIVE3.
STRENGTH OF 7,000 PSI.
THE FIRST FLOOR IS A STRUCTURAL SLAB. ALL UTILITIES MUST BE SUPPORTED
FROM THE SLAB AND UTILITIES MUST HAVE FLEXIBLE CONNECTIONS AS THE
UTILITY ENTERS THE BUILDING. REFER TO OTHER DISCIPLINES DRAWINGS FOR
SUPPORT DETAILS. AT LOCATIONS WHERE UTILITIES ENTER THE BUILDING, THE
11.
PENETRATION THROUGH THE FOUNDATION WALLS, PRECAST WALLS AND TURNDOWN
SLAB EDGES MUST BE 6" LARGER THAN THE UTILITY TO ALLOW 3" OF SPACE AROUND
THE UTILITY.
4.25 INCHES
SLAB-ON-GRADE 4,500 PSI
CONCRETE OTHERWISE NOTED 4,000 PSI
A.
2.
TO DIFFERENT PILES IF APPROVED BY THE CONTRACTING OFFICER.
ALLOWABLE (UNLESS OTHERWISE NOTED) DESIGN CAPACITIES ARE AS FOLLOWS
LATERAL (ULTIMATE FOR FREE HEAD CONNECTION) 4.5 TONS
COMPRESSION 98 TONS
TENSION 65 TONS
A.
B.
C.
(SEE A1/SB502 'PILE DESIGN CRITERIA' FOR ADDITIONAL INFORMATION):
DRIVING RESISTANCE IS BASED ON A FACTOR OF SAFETY
D. ULTIMATE DRIVING RESISTANCE
E.
OF 2.0 AND A 53 KIP ALLOWANCE FOR DOWNDRAG.
247 TONS
6. SEE SHEET PS003 FOR 'COMPONENTS AND CLADDING ULTIMATE
DESIGN' PRESSURE TABLE.
REFER TO THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS IN EACH SECTION.5.
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
12" = 1'-0"
S T
R U
C T
U R
A L
N O
T E
S
PS001
EHI JSC DWS
12860285
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
1/13/2023
COLD-FORMED METAL FRAMING NOTES:
COLD-FORMED METAL FRAMING MUST BE DESIGNED IN ACCORDANCE WITH THE
AMERICAN IRON AND STEEL INSTITUTE (AISI) "COLD-FORMED STEEL DESIGN
MANUAL". THE CONTRACTOR MUST SUBMIT SHOP DRAWINGS PREPARED BY A
REGISTERED PROFESSIONAL ENGINEER FOR THE DESIGN OF COLD-FORMED
METAL FRAMING, INCLUDING DESIGN LOADINGS AND REACTIONS APPLIED TO
THE SUPPORTING STRUCTURE.
COLD-FORMED METAL FRAMING (SIZES/GAGES) AND CONNECTIONS INDICATED
ON DRAWINGS ARE FOR PRICING PURPOSES ONLY. COLD-FORMED ENGINEER
MUST DESIGN AND DETAIL MEMBERS AND THEIR CONNECTIONS.
COLD-FORMED METAL FRAMING MEMBERS MUST BE FORMED OF CORROSION-
RESISTANT STEEL CONFORMING TO ASTM A653 WITH A MINIMUM YIELD
STRENGTH OF 33 KSI FOR TRACKS AND RUNNERS AND 33 KSI (50 KSI FOR 54 MILS
16 GAGE AND HEAVIER) FOR ALL OTHER MEMBERS.
WELDING MUST BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING
CODE - SHEET STEEL".
COLD-FORMED METAL FRAMING MEMBER SIZES AND GAGES INDICATED ARE IN
ACCORDANCE WITH THE STEEL STUD MANUFACTURERS ASSOCIATION (SSMA)
NOMENCLATURE.
COLD-FORMED METAL FRAMING MEMBERS MUST BE DESIGNED FOR THE LOADS
GIVEN IN THE GENERAL NOTES. THE DESIGN LOADS ARE UNFACTORED SERVICE
LOADS (ALL APPLICABLE FACTORS MUST BE APPLIED).
MAXIMUM LATERAL DEFLECTION OF COLD-FORMED FRAMING MEMBERS MUST BE
DETERMINED BY THE FOLLOWING TABLE:
COLD-FORMED METAL FRAMING MEMBERS MUST BE DESIGNED FOR ALL FRAMING
CONDITIONS FOUND IN THE STRUCTURE, INCLUDING WALLS, CORNERS,
HEADERS, AND JAMBS. SOME CONDITIONS MAY REQUIRE MODIFICATION OF
COLD-FORMED FRAMING MEMBERS (SUCH AS NOTCHING OR REVISING SIZES) OR
MULTIPLE STUDS TO SUPPORT INCREASED LOADS. IT IS THE RESPONSIBILITY OF
THE CONTRACTOR TO COORDINATE ALL CONDITIONS AND DETAILS.
CROSS BRIDGING OR FULL-DEPTH BLOCKING IS REQUIRED AT AND ROOF
RAFTERS NOT RECEIVING CEILING SHEATHING AND AT WALL STUDS NOT
RECEIVING SHEATHING ON BOTH FACES. UNLESS OTHERWISE INDICATED,
CROSS BRIDGING MUST BE SIMPSON TB (OR EQUIVALENT); MAXIMUM
BRIDGING/BLOCKING SPACING MUST BE 8'-0" ON-CENTER OR AT 1/3 POINTS
OF MEMBER SPAN, WHICHEVER IS LESS. COORDINATE EXTENTS OF WALL
AND CEILING SHEATHING WITH THE ARCHITECTURAL DRAWINGS.
COLD-FORMED METAL FRAMING CONNECTIONS TO THE STRUCTURE MUST BE
DESIGNED FOR ALL FRAMING CONDITIONS. CONNECTIONS ARE SCHEMATICALLY
SHOWN ON THE STRUCTURAL DRAWINGS. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO COORDINATE ALL CONNECTION CONDITIONS AND LOCATIONS.
STUD USE L/y RATIO (LIMIT)
BACKING UP METAL PANEL L/360 (MANUF. RECOMMENDATION)
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
POST-INSTALLED ANCHOR NOTES:
POST-INSTALLED ANCHORS MUST BE CAPABLE OF WITHSTANDING DESIGN
LOADS INDICATED ON THE DRAWINGS. APPLICABLE POST-INSTALLED ANCHOR
TYPE(S) ARE AS FOLLOWS:
ANCHORAGE TO CRACKED AND/OR UNCRACKED CONCRETE:
ADHESIVE ANCHORS OR MECHANICAL ANCHORS, AS INDICATED.
REBAR DOWELING INTO CRACKED AND/OR UNCRACKED CONCRETE:
ADHESIVE ANCHORS
ANCHORAGE TO SOLID GROUTED MASONRY:
ADHESIVE ANCHORS AS INDICATED
ANCHOR CAPACITY MUST BE BASED ON TECHNICAL DATA PUBLISHED BY THE
ANCHOR MANUFACTURER OR SUCH OTHER METHOD AS APPROVED BY THE
STRUCTURAL ENGINEER OF RECORD. CONTRACTOR MUST PROVIDE
CALCULATIONS DEMONSTRATING THE CHOSEN ANCHOR IS CAPABLE OF
ACHIEVING THE PERFORMANCE VALUES INDICATED. PRODUCTS SUBMITTED
WILL BE EVALUATED BY SHOWING ICC ESR COMPLIANCE WITH THE RELEVANT
BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION
CATEGORY AND AVAILABILITY OF COMPREHENSIVE INSTALLATION
INSTRUCTIONS. ADHESIVE ANCHOR EVALUATION WILL ALSO CONSIDER CREEP,
IN-SERVICE TEMPERATURE AND INSTALLATION TEMPERATURE.
INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS INCLUDED IN
ANCHOR PACKAGING.
OVERHEAD ADHESIVE ANCHORS MUST BE INSTALLED USING A PROPERLY
TESTED AND APPROVED INSTALLATION METHOD.
THE CONTRACTOR MUST ARRANGE A REPRESENTATIVE OF THE ANCHOR
MANUFACTURER TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL
ANCHORING PRODUCTS. THE STRUCTURAL ENGINEER OF RECORD MUST
RECEIVE DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR'S
PERSONNEL WHO INSTALL ANCHORS ARE TRAINED PRIOR TO THE
COMMENCEMENT OF INSTALLING ANCHORS.
ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT
ANCHORS AND PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL
ANCHORS IN ACCORDANCE WITH SPACING AND EDGE CLEARANCES INDICATED
ON THE DRAWINGS.
EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE MAY CONFLICT
WITH SPECIFIC ANCHOR LOCATIONS. UNLESS OTHERWISE NOTED, THE
REINFORCING BARS CANNOT BE CUT. THE CONTRACTOR MUST REVIEW THE
EXISTING STRUCTURAL DRAWINGS AND MUST LOCATE THE POSITION OF THE
REINFORCING BARS AT THE LOCATIONS OF THE CONCRETE ANCHORS BY GPR
X-RAY, CHIPPING OR OTHER MEANS.
1.
2.
3.
4.
5.
6.
7.
1.
1.
1.
A.
B.
C.
STRUCTURAL STEEL NOTES:
STRUCTURAL STEEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FOURTEENTH EDITION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION
(AISC 360-10) "STEEL CONSTRUCTION MANUAL" - ALLOWABLE STRENGTH DESIGN.
STRUCTURAL STEEL MUST COMPLY WITH THE FOLLOWING SPECIFICATIONS:
RECTANGULAR AND SQUARE HSS - ASTM A500, GRADE C, Fy=50 KSI
HEADED STUDS - ASTM A 108, GRADES 1015 THROUGH 1020, TYPE B,
Fu=65 KSI
ALL OTHER STRUCTURAL STEEL SHAPES, PLATES AND BARS - ASTM A36,
Fy=36 KSI (UNLESS OTHERWISE NOTED)
WELDING MUST BE IN ACCORDANCE WITH AWS D1.1, "STRUCTURAL WELDING
CODE - STEEL". WELD ELECTRODES MUST BE E70XX. CONTINUOUS 1/4" FILLET
WELDS ARE REQUIRED UNLESS OTHERWISE NOTED.
SEE THE ARCHITECTURAL, CIVIL, MECHANICAL, PLUMBING AND ELECTRICAL
DRAWINGS FOR ADDITIONAL STEEL (IF ANY) NOT SHOWN ON THE STRUCTURAL
DRAWINGS.
UNLESS OTHERWISE NOTED, THE TOP OF ALL STEEL COLUMNS MUST HAVE A
STEEL CAP PLATE. UNLESS OTHERWISE DETAILED OR NOTED, MINIMUM CAP
PLATE DIMENSIONS MUST MATCH COLUMN WIDTH AND DEPTH AND MINIMUM
THICKNESS OF CAP PLATE MUST EQUAL COLUMN WEB THICKNESS (1/2" MINIMUM).
STRUCTURAL STEEL NOTED TO BE GALVANIZED MUST CONFORM TO ASTM A123
OR ASTM A153. GALVANIZE STRUCTURAL STEEL AFTER FABRICATION WHERE
PRACTICAL. REPAIR DAMAGED GALVANIZED COATING USING ASTM A780 ZINC-
RICH PAINT.
A.
B.
C.
STEEL JOIST NOTES:
STEEL JOISTS MUST CONFORM TO THE LATEST EDITION OF THE STEEL JOIST
INSTITUTE (SJI) STANDARD SPECIFICATIONS.
PREPARE AND SUBMIT FOR REVIEW SHOP DRAWINGS SHOWING THE LAYOUT OF
JOIST MEMBERS, SPECIAL CONNECTIONS, JOINING AND ACCESSORIES. INCLUDE
MARK, NUMBER, TYPE, LOCATION AND SPACING OF JOISTS AND BRIDGING.
THE JOIST MANUFACTURER MUST BE RESPONSIBLE FOR CONTINUOUS JOIST
BRIDGING LINES SATISFYING THE REQUIREMENTS OF THE SJI SPECIFICATION
FOR THE TOP AND BOTTOM CHORDS OF ALL STEEL JOISTS, AS WELL AS ANY
ADDITIONAL BRIDGING/BRACING SHOWN OR REQUIRED FOR JOISTS SUBJECTED
TO NET UPLIFT OR OTHER SPECIAL LOADS. ALL REQUIRED JOIST BRIDGING MUST
BE CLEARLY INDICATED ON THE SHOP DRAWINGS. CROSS-BRIDGING IS
REQUIRED AT CHANGES OF JOIST DEPTHS AND ENDS OF ALL BRIDGING LINES,
UNLESS SUCH ENDS ARE PROPERLY ANCHORED INTO INTERSECTING INTERIOR
OR END WALLS. ALL BRIDGING AND BRIDGING ANCHORS MUST BE COMPLETELY
INSTALLED BEFORE PLACING OF ANY CONSTRUCTION LOADS ON THE JOISTS.
ROOF JOISTS MUST BE DESIGNED FOR A NET UPLIFT LOAD OF 56 PSF. ONE-THIRD
STRESS INCREASE NOT PERMITTED FOR LOAD COMBINATIONS INVOLVING WIND
PER IBC SECTION 1605.3.1.1.
1.
2.
3.
4.
5.
STEEL DECK NOTES:
STEEL DECK MUST CONFORM TO THE LATEST EDITION OF THE AMERICAN IRON
AND STEEL INSTITUTE (AISI), "SPECIFICATION FOR THE DESIGN OF COLD-FORMED
STEEL STRUCTURAL MEMBERS" AND THE STEEL DECK INSTITUTE (SDI), "DESIGN
MANUAL FOR COMPOSITE DECKS, FORM DECKS, AND ROOF DECKS."
STEEL DECK UNITS MUST COMPLY WITH THE FOLLOWING:
1 1/2" ROOF DECK MUST BE 20 GAGE GALVANIZED TYPE B RIB
DECK SPANNING PERPENDICULAR TO SUPPORTS UNLESS OTHERWISE
NOTED. ATTACH DECK TO STRUCTURAL STEEL SUPPORTS WITH 5/8"
DIAMETER PUDDLE WELDS AT EVERY RIB, INCLUDING RIBS WHERE
SIDELAPS OCCUR. FASTEN ADJACENT DECK UNITS WITH #10 SELF-
TAPPING HEX HEAD SCREWS AT 1/3 POINTS BETWEEN SUPPORTS ALONG
SIDELAPS AND FASTEN EDGEMOST DECK PANEL TO STEEL FRAMING WITH
5/8" DIAMETER PUDDLE WELDS AT SAME SPACING AS SIDELAP FASTENERS.
WELDING MUST BE IN ACCORDANCE WITH AWS D1.3 "STRUCTURAL WELDING
CODE - SHEET STEEL". FIELD WELDS MUST BE WIRE BRUSHED AND PRIMED
PAINTED IN ACCORDANCE WITH THE SPECIFICATIONS.
PERMANENT SUSPENDED LOADS SUCH AS SUSPENDED CEILINGS, LIGHT
FIXTURES, DUCTS, OR OTHER UTILITIES MUST NOT BE SUPPORTED BY STEEL
ROOF DECK.
DURING STEEL DECK ERECTION AND ROOFING OPERATIONS DISTRIBUTE
CONSTRUCTION LOADS TO PREVENT DAMAGE TO DECK. CONCENTRATED
CONSTRUCTION LOADS OF 200 POUNDS OR LESS DISTRIBUTED OVER A 1'-0" WIDE
SECTION OF DECK MUST NOT REQUIRE ANY FURTHER DISTRIBUTION. USE
WORKING PLATFORMS FOR CONCENTRATED CONSTRUCTION LOADS OF OVER
200 POUNDS, SUCH THAT THE RESULTING UNIFORM CONSTRUCTION LOAD ON
THE DECK DOES NOT EXCEED 50 PSF.
PREPARE AND SUBMIT SHOP DRAWINGS FOR REVIEW SHOWING THE LAYOUT AND
TYPES OF DECK UNITS, ANCHORAGE DETAILS AND CONDITIONS REQUIRING
CLOSURE STRIPS, SUPPLEMENTARY FRAMING AND OTHER ACCESSORIES.
TOUCH-UP ALL SCARRED, ABRADED AND RUST AREAS IN STEEL DECK IN
ACCORDANCE WITH THE SPECIFICATIONS.
1.
2.
3.
4.
5.
6.
7.
A.
1.
2.
3.
4.
5.
6.
ALL JOISTS ARE SPECIAL JOISTS AND THE JOIST MANUFACTURER MUST SUBMIT
SIGNED AND SIGNED CALCULATIONS FOR DESIGN OF JOIST. IN ADDITION TO
STEEL JOIST INSTITUTE (SJI) DESIGN CRITERIA, ALL JOIST MUST BE DESIGNED
FOR THE FOLLOWING LOAD CRITERIA:
UNIFORM LOAD INDICATED BY STEEL JOIST INSTITUTE (SJI) DESIGNATION.
A LOAD COMBINATION OF TOTAL UNIFORM LOAD AND A SEISMIC AXIAL
LOAD OF 1,600 POUNDS.
A.
B.
CONCRETE MASONRY HAS BEEN DESIGNED IN ACCORDANCE WITH THE
AMERICAN CONCRETE INSTITUTE (ACI) "BUILDING CODE REQUIREMENTS AND
SPECIFICATIONS FOR MASONRY STRUCTURES" TMS 402/602-16.
CONCRETE MASONRY CONSTRUCTION MUST CONFORM TO THE "BUILDING CODE
REQUIREMENTS AND SPECIFICATIONS FOR MASONRY STRUCTURES" TMS 402/602-16.
CONCRETE MASONRY UNITS MUST CONFORM TO ASTM C90 AND BE MADE WITH
LIGHTWEIGHT OR NORMAL WEIGHT AGGREGATE. THE COMPRESSIVE STRENGTH
OF MASONRY, F'm, EXPRESSED AS FORCE PER UNIT OF NET CROSS-SECTIONAL
AREA, MUST BE 2,000 PSI AT 28 DAYS.
REINFORCING STEEL MUST COMPLY WITH ASTM A615, GRADE 60. SHOP
FABRICATE REINFORCING BARS SHOWN TO BE BENT OR HOOKED.
GROUT MUST COMPLY WITH ASTM C476, AND MUST BE PROPORTIONED TO
OBTAIN A 28 DAY COMPRESSIVE STRENGTH OF 2,000 PSI.
MORTAR MUST COMPLY WITH ASTM C270, TYPE S OR M. AGGREGATE FOR
MORTAR MUST COMPLY WITH ASTM C144. AGGREGATE FAILING TO COMPLY WITH
ASTM C144 GRADATION REQUIREMENTS MAY BE USED PROVIDED THE MORTAR
CAN BE PREPARED TO COMPLY WITH THE AGGREGATE RATIO, WATER
RETENTION AND COMPRESSIVE STRENGTH REQUIREMENTS OF THE PROPERTY
SPECIFICATIONS OF ASTM C270. USE TYPE M BELOW GRADE AND TYPE S ABOVE
GRADE (UNLESS CELLS ARE GROUTED SOLID).
VERTICAL REINFORCING BARS MUST BE THE GIVEN SIZE AND SPACING SHOWN.
LAP REINFORCING AT ALL SPLICES AS FOLLOWS:
#3 - 19" #4 - 25" #5 - 31"
REBAR DOWELS MUST BE THE SAME SIZE AND SPACING AS VERTICAL
REINFORCING FROM FOUNDATION. DOWELS MUST HAVE STANDARD ACI HOOKS.
DISCONTINUE ALL HORIZONTAL REINFORCING AT CONTROL JOINTS.
HORIZONTAL JOINT REINFORCING MUST BE STANDARD 9 GAGE LADDER TYPE IN
CMU WALLS AT 16" ON-CENTER. JOINT REINFORCING MUST COMPLY WITH ASTM
A951 AND MUST BE HOT-DIPPED GALVANIZED ACCORDING TO ASTM A153, CLASS B.
GROUT ALL CELLS SOLID BELOW FINISHED FIRST FLOOR.
VERTICAL REINFORCING MUST HAVE BAR POSITIONERS AT SPACING NOT TO
EXCEED 200 BAR DIAMETERS, AT GROUT LIFT HEIGHTS OR BAR SPLICE
LOCATIONS, WHICHEVER IS LESS.
#6 - 52" #7 - 67" #8 - 93"
#9 - 119"
#10 OR LARGER -
'MECHANICALLY SPLICED'
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
A.
B.
C.
D.
E.
F.
G.
H.
CONCRETE MASONRY NOTES:
NON-LOAD BEARING MASONRY WALLS ARE INDICATED ON THE ARCHITECTURAL
DRAWINGS AND MUST BE REINFORCED WITH #4 AT 48" ON-CENTER VERTICAL
WALL REINFORCEMENT.
REFER TO THE PARTITION TYPES ON THE ARCHITECTURAL DRAWINGS FOR
CONCRETE MASONRY WALLS THAT MUST BE GROUTED SOLID.
13.
14.
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
12" = 1'-0"
S T
R U
C T
U R
A L
N O
T E
S
PS002
EHI JSC DWS
12860286
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
STRUCTURAL ABBREVIATION LIST:
PLUS/MINUS
DIAMETER
CENTERLINE
ON CENTER
ANCHOR BOLT
ARCHITECT or ARCHITECTURAL
BOTTOM
BAR DIAMETER
BUILDING
BRACING
BRIDGING
CENTER OF GRAVITY
CAST IN PLACE
CONCRETE MASONRY UNIT
COLUMN
CONCRETE
CONTINUOUS
COORDINATE
DETAIL
DIAMETER
DRAWING
EACH FACE
EACH WAY
ELEVATION
ELECTRICAL
ELEVATOR or ELEVATION
EXISTING
EXPANSION
FACE OF
FIRST RISER
FINISH or FINISHED
FOOTING
HOLLOW CORE
HORIZONTAL
JOIST BEARING ELEVATION
KIPS PER SQUARE FOOT
KIPS PER SQUARE INCH
LONG LEG HORIZONTAL
LONG LEG OUTSTANDING
MIDDLE OF SLAB
MIDDLE OF WALL
MANUFACTURER or
MATERIAL
MECHANICAL
PRECAST
PRE-STRESSED
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PLUMBING
RADIUS
REINFORCED or REINFORCING
REQUIRED
SLAB-ON-GRADE
STEPPED FOOTING
SECTION
STANDARD
STIRRUP
STRUCTURAL
TOP OF STEEL
TEMPERATURE
TYPICAL
UNLESS OTHERWISE NOTED
VERTICAL
WORKING POINT
WELDED WIRE REINFORCEMENT
CMU
ELEV.
J.B.E.
K.S.F.
K.S.I.
MANUF.
PSF
PSI
REINF.
U.O.N.
VERT.
W.P.
W.W.R.
S.O.G.
S.F.
SECT.
STD.
STIR.
STRUCT.
T.O.S.
TEMP.
TYP.
M.O.S.
M.O.W.
MATL.
MECH.
P.C.
P.S.
PLUMB.
R.
REQD.
FTG.
H.C.
HORIZ.
LLH
LLO
DET.
DIA.
DWG.
E.F.
E.W.
EL.
ELEC.
EXIST.
EXP.
F.O.
F.R.
FIN.
B.
B.D.
BLDG.
BRCG.
BRDG.
C.G.
C.I.P.
COL.
CONC.
CONT.
COORD.
Ø
CL
o/c
A.B.
ARCH.
MANUFACTURER'S
ACI
ASTM
AMERICAN CONCRETE INSTITUTE
AMERICAN SOCIETY FOR
TESTING AND MATERIALS
CANT. CANTILEVER
SCHED. SCHEDULE
GALV. GALVANIZED
ENG. ENGINEER
AISC AMERICAN INSTITUTE OF
STEEL CONSTRUCTION
BTWN. BETWEEN
SIM. SIMILAR
MAX.
MIN.
MAXIMUM
MINIMUM
N.T.S.
OSB
NOT TO SCALE
ORIENTED STRAND BOARD
DBL.
DIAG.
DOUBLE
DIAGONAL
EMB. EMBED or EMBEDMENT
STIFF. STIFFENER
REF. REFERENCE
PROJ. PROJECTION
B.E.J. BUILDING EXPANSION JOINT
G.C. GENERAL CONTRACTOR
F.L. FULL LENGTH
ADJ. ADJACENT
BRG. BEARING
REVISIONREV.
C.J.P. COMPLETE JOINT PENETRATION
LSH
LSV
LONG SIDE HORIZONTAL
LONG SIDE VERTICAL
EQUIV. EQUIVALENT
LONG LEG VERTICALLLV
SHORT LEG OUTSTANDINGSLO
POWDER ACTUATED FASTENERPAF
STEEL JOIST INSTITUTES.J.I.
PRE-ENGINEERED BUILDINGPEB
S.D.I. STEEL DECK INSTITUTE
E.O. EDGE OF
CONN. CONNECT or CONNECTION
P.T. PRESSURE TREATED
MASONRYMAS.
STRUCTURAL STEEL
ARCHITECTURALLY EXPOSEDAESS
SEISMIC EXPANSION JOINTS.E.J.
A.R. ANCHOR ROD
DECK ASSEMBLY
SLOPED INTEGRAL ROOFS.I.R.D.A.
POST-TENSIONEDP/T
POUNDS PER LINEAR FOOTPLF
OPP. OPPOSITE
SQUARESQ.
CAST-IN-PLACE CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE
(THESE NOTES MUST BE USED FOR ALL SPLICES UNLESS NOTED OTHERWISE ON DRAWINGS):
91"
101"
#10
#11
70"
78"
91"
101"
118"
131"
61"
67"
79"
87"
79"
87"
102"
114"
92"
102"78"
54"
60"
71" 71"
78"
REGULAR
CLASS
f'c = 3,000 PSI
B
29"
22"
43"
72"
63"
36"
81"
A
#8
#9
#6
#7
55"
62"
33"
48"
#4
#5
#3
22"
28"
17"
Fy =
60 KSI
BAR
SIZE
TENSION BARS
BABABA
72"
81"
63"
43"
93"
105"
48"
54"
56"
81"
29"
42"
29"
36"
22"
19"38"
47" 24"
28" 15"
37"
62"
54"
70"
62"
70"
37"
54"
81"
91"
49"
71"
25"
19"
31"
25"
31"
19"
33"
41"
25"
REGULAR
CLASS
f'c = 4,000 PSI
TOP
CLASS
TOP
CLASS
BABA
29"
22"
44"
72"
63"
36"
81"
49"
56"
34"
63"
43"
48"
26"
38"
56"
63"
34"
49"
28"
23"17"
22"
13" 17"
23"
28"
17"
CLASS
REGULAR
f'c = 5,000 PSI
CLASS
TOP
39"
43"
30"
34"
23"
27"
15"
19"
12" f'c = ALL
COMPRESSION BARS
65"
73"
85"
94"
85"
94"
110"
122"
BABA
51"
58"
31"
45"
21"
26"
16"
40"
67"
59"
75"
67"
75"
40"
59"
87"
98"
52"
75"
27"
21"
34"
27"
34"
21"
36"
44"
26"
REGULAR
CLASS
f'c = 3,500 PSI
TOP
CLASS
TOP BARS ARE HORIZONTAL BARS, SPLICED SO THAT 12" OR MORE OF FRESH CONCRETE IS CAST IN THE MEMBER
CLASS A SPLICES MAY BE USED ONLY WHEN 50% OR LESS OF THE BARS ARE SPLICED WITHIN THE LAP SPLICE LENGTH.
CLASS B SPLICES MUST BE USED FOR ALL SPLICES IN SLABS, BEAMS, JOISTS, WALLS, MOMENT RESISTING COLUMNS, THE BAR LAP SPLICE LENGTHS MUST BE MULTIPLIED BY 1.5 WHEN EITHER OF THE FOLLOWING IS TRUE:
CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN ONE BAR DIAMETER, CLEAR COVER IS LESS THAN ONE BAR DIAMETER AND STIRRUPS OR TIES ALONG THE LENGTH OF THE SPLICE ARE LESS THAN THE CODE MINIMUM.
CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN 2 BAR DIAMETERS AND CLEAR COVER IS LESS
THAN ONE BAR DIAMETER.
FOR ALL LIGHTWEIGHT CONCRETE, LAP LENGTHS MUST BE MULTIPLIED BY 1.3.
TIES AND STIRRUPS MUST NOT BE SPLICED UNLESS APPROVED BY THE ENGINEER OF RECORD. ROUND COLUMN
AND JAMB COLUMNS, UNLESS THEY MEET THE REQUIREMENTS OF NOTE #2 ABOVE.
BELOW THE REINFORCING BAR.
3.
B.
6.
A.
4.
5.
2.
1.
TIES MAY BE SPLICED USING CLASS A LAPS.
CAST-IN-PLACE CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE NOTES
SEISMIC FORCE RESISTINGSFRS
SYSTEM
COMPONENTS AND CLADDING DESIGN PRESSURES (PSF)
ROOF
ZONE
TRIBUTARY AREA (SQ. FT.)
WALL
ZONE
10 50 250
TRIBUTARY AREA (SQ. FT.)
10 50 250
+46.0 -61.0
+46.0 -50.0
+41.0 -52.0
+41.0 -45.0
+37.0 -44.0
+37.0 -41.0
+46.0 -84.0
+46.0 -84.0
+41.0 -63.0
+41.0 -63.0
+37.0 -54.0
+37.0 -54.0
+21.0 -50.0 +17.0 -47.0 +16.0 -46.0
NOTES:
PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD OR AWAY
FROM THE SURFACES, RESPECTIVELY.
WIDTH OF COEFFICIENT PRESSURE ZONE, a = 14 FEET. SEE 'COMPONENT AND
1.
2.
CLADDING LEGEND' ON THIS SHEET FOR LOCATIONS.
2 1 2
COMPONENT AND CLADDING LEGEND
TYPICAL UNIT PLAN TYPICAL SIDE WALL
5 4 5
8' (TYP.) 8' (TYP.)
ALL WIND PRESSURES ARE ULTIMATE LOADS. FOR SERVICE LOAD PRESSURES,3.
MULTIPLY THE ABOVE VALUES BY 0.6 PER ASCE 7-16.
16' 16'
10'
LO
W
E N
D
H
IG
H E
N D
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
12" = 1'-0"
S T
R U
C T
U R
A L
N O
T E
S A
N D
A B
B R
E V
IA
T
IO
N
S
PS003
EHI JSC DWS
12860287
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
FOUNDATION AND GROUND FLOOR SLAB PLAN LEGEND :
= SANITARY OR STORM SEWER PIPING BELOW
SLAB - COORDINATE WITH THE PLUMBING DRAWINGS
(PIPING PARTIALLY SHOWN) SEE THE PLUMBING
DRAWINGS FOR ADDITIONAL PIPING NOT SHOWN
GB-X GRADE BEAM MARK - SEE SCHEDULE AND
TYPICAL DETAIL ON SHEET PSB502
P-X = PILE CAP MARK - SEE TYPICAL DETAILS ON
SHEET PSB501
PCX = PILE CAP IDENTIFICATION NUMBER - FOR
REFERENCE ONLY
SF = STEPPED FOUNDATION - SEE TYPICAL DETAIL
ON SHEET PSB502
= TOP OF PILE CAP / GRADE BEAM ELEVATION -
MEASURED FROM REFERENCE ELEVATION 0'-0"
(-X'-X")
TEST PILE LOCATION=
TEST PILE NUMBERTP-X
"T" SUFFIX ON PILE CAP MARK INDICATES
TENSION PILE CAP
P-XT
= TOP OF CONCRETE WALL ELEVATION - MEASURED
FROM REFERENCE ELEVATION 0'-0"
<-X'-X">
X = COLUMN GRID MARK
PILE
FOUNDATION AND GROUND FLOOR SLAB PLAN LEGEND :
= TOP OF SLAB ELEVATION
= CHANGE IN SLAB SLOPE - SEE THE ARCHITECTURAL
DRAWINGS FOR EXACT LOCATION
= EXTENT OF SLAB SLOPE - SEE THE ARCHITECTURAL
DRAWINGS FOR EXACT LOCATION
X = COLUMN GRID MARK
FLOOR DRAIN - COORDINATE WITH THE ARCHITECTURAL AND
PLUMBING DRAWINGS
FD FD
= FIRST RISER - SEE THE ARCHITECTURAL DRAWINGS
FOR DETAILS AND EXACT LOCATION
= RAIN LEADER - SEE THE ARCHITECTURAL DRAWINGS
F/R
RL
= BUILDING FINISHED FLOOR ELEVATION0'-0"
X'-X"
SLOPE DIRECTION OF SLAB SLOPE
= SLAB-ON-GRADE WARP LINE
= APPROXIMATE ACTUAL FINISHED GRADE ELEVATION -
FOR GRADING SEE THE CIVIL DRAWINGS
XX.X'
FOUNDATION AND GROUND FLOOR SLAB PLAN KEY NOTES :
1. GROUND FLOOR MUST BE A 8" THICK STRUCTURAL SLAB-ON-GRADE, REINFORCED AS
SHOWN ON PLAN, OVER 15 MIL. VAPOR RETARDER MINIMUM OVER 4" DEPTH OF POROUS
FILL.
2. GROUND FLOOR MUST BE A 8" THICK STRUCTURAL SLAB-ON-GRADE, REINFORCED AS
SHOWN ON PLAN, OVER 4" DEPTH OF POROUS FILL.
3. REGION OF SLAB SURFACE WARP AND DIRECTION FROM HIGH POINT TO LOW POINT.
MAINTAIN SPECIFIED SLAB THICKNESS THROUGHOUT WARP REGION.
4. EXISTING CREOSOTE TREATED TIMBER PILES TO REMAIN. CUT PILES OFF AT ELEVATION
REQUIRED TO CLEAR BOTTOM OF SLABS AND FOUNDATIONS BY 2'-0". DISPOSE OF PILE CUT
OFFS AS SPECIFIED.
5. TRENCH DRAIN - SEE THE PLUMBING AND ARCHITECTURAL DRAWINGS FOR ADDITIONAL
INFORMATION.
6. DOWELED STRUCTURAL SLAB-ON-GRADE EXPANSION JOINT - SEE RELEVANT FOUNDATION
SECTION.
7. CONDUCT STATIC LOAD TEST ON PILE IN ADDITION TO PDA TESTING.
8. EXISTING GEOTHERMAL WELLS TO REMAIN. COORDINATE PILE LOCATIONS WITH
LOCATIONS OF WELLS. CUT WELLS OFF AT ELEVATION REQUIRED TO CLEAR BOTTOM OF
SLAB AND FOUNDATIONS BY 2'-0". DISPOSE OF WELL CUT OFF AS REQUIRED.
XGENERAL FOUNDATION AND GROUND FLOOR SLAB PLAN NOTES :
A. SEE THE CIVIL DRAWINGS FOR ACTUAL FINISHED FLOOR ELEVATION AND FINISHED
GRADES. TOP OF SLAB VARIES (SEE SHEET PSB105). TOP OF SLAB EQUALS FINISHED
FLOOR ELEVATION AND MUST SERVE AS THE REFERENCE ELEVATION 0'-0".
B. FOR THE STRUCTURAL NOTES AND ABBREVIATIONS SEE SHEETS PS001, PS002 AND
PS003.
C. FOR DIMENSIONS NOT SHOWN SEE THE DIMENSION PLAN ON SHEET PSB102 AND THE
ARCHITECTURAL DRAWINGS.
D. TOP OF ALL PILES CAPS AND GRADE BEAMS MUST BE AS INDICATED ON PLAN.
E. PILE CAP AND GRADE BEAM CENTERLINES MUST COINCIDE WITH COLUMN CENTERLINES,
UNLESS OTHERWISE NOTED.
F. COORDINATE TOP OF CAST-IN-PLACE CONCRETE RAMP SLAB ELEVATION
WITH THE PRECAST DRAWINGS AND ELEVATIONS.
G. SEE SHEETS PSB106 AND PSB107 FOR INFORMATION REGARDING PRECAST LOADS
AND ADDITIONAL INFORMATION REGARDING OUR ASSUMPTIONS FOR THE
PRECAST CONCRETE SYSTEM.
H. PRECAST CONCRETE ELEMENTS SHOWN THUS ON PLAN ( ).
J. CAST-IN-PLACE CONCRETE ELEMENTS SHOWN THUS ON PLAN ( ).
K. ALL UTILITIES (PIPES, CONDUITS, ETC.) BENEATH THE SLAB MUST BE STRUCTURALLY
SUPPORTED BY THE STRUCTURAL SLAB. SEE THE PLUMBING, MECHANICAL AND
ELECTRICAL DRAWINGS FOR THE APPROPRIATE MEANS OF ATTACHMENT. .
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
12" = 1'-0"
F O
U N
D A
T
IO
N A
N D
G R
O U
N D
F
LO
O R
S
LA
B P
LA
N
N O
T E
S A
N D
L E
G E
N D
S
PSB100
EHI JSC DWS
12860288
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
A A
B B
C C
D D
A.2 A.2
C.8 C.8
18'-0" 30'-0" 48'-0" 48'-0" 48'-0" 48'-0" 48'-0" 30'-0" 18'-0"
'-2
'-5
'-1
0"
'-5
'-2
F.O. PRECAST
PANEL (TYP.)
PRECAST
CONCRETE
WALL PANEL
(TYP.)
PRECAST
CONCRETE
COLUMN (TYP.)P-4
P-2
P-5 P-5 P-5
P-4 P-4 P-2
P-2
P-4
P-2P-2
P-4
P-2
P-2P-4P-2
P-2 P-2
P-2 P-4
P-2
P-2
P-3
P-2
P-3
P-2
P-5
P-2 P-2 P-2 P-2 P-2
P-2
P-3
P-2
P-3
P-2
P-5
P-4 P-4
P-8
P-24T
P-24T
P-4TP-4P-4P-4TP-4T
P-3
P-4TP-4P-4T
P-5
P-18T
P-6T
P-4T P-4 P-4 P-3
P-4T P-4T P-4 P-4 P-4T
P-2P-5P-2
P-5 P-2P-5
P-2 P-5
P-2P-4
CAST-IN-PLACE
CONCRETE WALL
'-3
'-2
'-2
'-3
15'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0" 24'-0"
14'-0" 18'-0"
P-4
24'-0" 24'-0"
'-3
'-7
'-8
'-4
'-3
'-3
'-4
" 31 '-1
1"
'-1 1"
15'-0"
10"
10"
10"
10"
10"
10"
4' -2
6'-2" 10'-4" 1'-6"
'-1
0"
1' -6
1' -2
4' -2
4"4"
4"
2' -1
2' -1
1'-6" 10'-4" 6'-2"
4"
'-1
0" 1'
-6
1' -2
2'
-1
1'-6" 10'-4" 6'-2"
4"
4' -2
4"
'-1
0" 1'
-6
1' -6
'-1
0"
4"
1' -2
2'
-1
6'-2" 10'-4" 1'-6"
4"
4' -2
1'-2"
1'-2"
6'-0"
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
1/16" = 1'-0"
F O
U N
D A
T
IO
N D
IM
E
N S
IO
N
P
LA
N
PSB101
EHI JSC DWS
12860289
1/16" = 1'-0" (FOR PLAN NOTES AND LEGEND SEE SHEET PSB100)
FOUNDATION DIMENSION PLAN
NOTE:
THE PURPOSE OF THE DRAWING IS TO PROVIDE DIMENSIONS LOCATING THE PILE CAPS, GRADE BEAMS AND OTHER PERTINENT ITEMS TO PLACE THE FOUNDATION. SEE SHEETS PSB103, PSB104 AND PSB105
FOR ADDITIONAL INFORMATION.
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
1 2 3 4 5 6 7 98 10
B
C
D
A.2
C.8
PRECAST
CONCRETE
WALL PANEL
(TYP. U.O.N.)
PRECAST
CONCRETE
COLUMN (TYP.)
CAST-IN-PLACE
CONCRETE WALL
SF
(TYP.)
TYP.
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
1/16" = 1'-0"
F O
U N
D A
T
IO
N P
IL
E
P
LA
N
PSB102
EHI JSC DWS
12860290
1/16" = 1'-0" (FOR PLAN NOTES AND LEGEND SEE SHEET PSB100)
FOUNDATION PILE PLAN
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
NOTE:
THE PURPOSE OF THIS DRAWING IS TO SHOW THE RELATIONSHIP OF EXISTING PILES AND
GEOTHERMAL WELLS TO NEW PILES. THIS DRAWING IS FOR REFERENCE ONLY.
BASE BID ON THIS REFERENCED SHEET TO DETERMINE WHICH EXISTING PILES MUST BE CUT
AND FOR MATERIAL QUANTITY OF PILE LENGTH TO BE REMOVED, BASE BID ON TOP OF PILE
ELEVATION OF 2'-6" BELOW EXISTING FINIAHED FLOOR ELEVATION. FOR EFFORT AND LABOR TO CUT THE PILES AND SURVEY THE PILES, BASE BID ON TOP OF PILE ELEVATION OF 5'-6" BELOW EXISTING BUILDING FINISHED FLOOR ELEVATION. SEE CIVIL DRAWINGS FOR EXISTING BUILDING
FINISH FLOOR ELEVATION.
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
B
C
D
A.2
C.8
G B
-3
GB-3
G B
-3
P-4
P-2
P-2P-2
P-4
P-2
P-2P-4P-2
P-2
P-2
G B
-3
G B
-3
GB-3
GB-1 GB-1
G B
-3
G B
-3
GB-3
G B
-1 G
B -1
G B
-3
G B
-3
GB-3
G B
-1 G
B -1
G B
-2
PRECAST
CONCRETE
WALL PANEL
(TYP. U.O.N.)
PRECAST
CONCRETE
COLUMN (TYP.)
C1
PSB411
C2
PSB411
C1
PSB411
C1
PSB411
C3
PSB411
A1
PSB411
C1
PSB411
C1
PSB411
A1
PSB411
A4
PSB411
C1
PSB412
A2
PSB411
C4
PSB411
C1
PSB411
C4
PSB411
C3
PSB411
C3
PSB411
C1
PSB411
A1
PSB411
GB-1
GB-1
GB-1
GB-1
CAST-IN-PLACE
CONCRETE WALL
C2
PSB411
P-2 P-4 P-4
P-2P-2
P-2
P-3
P-2
P-3
P-2
P-2 P-5 P-2 P-5 P-2 P-5 P-2 P-4 P-2 P-4
P-2
P-3
P-2
P-3
P-2
P-4
P-4
P-4TP-4P-4P-4TP-4TP-3P-4TP-4P-4T
P-5
P-18T
P-4T P-4 P-4 P-3
P-4T P-4T P-4 P-4
P-4T
P-2P-5P-2P-5P-2P-5P-2P-5P-2P-4
GB-1 GB-1 GB-1 GB-1 GB-1GB-1 GB-1
GB-1
P-5 P-5
P-8
GB-1 GB-1 GB-1 GB-1 GB-1
GB-1
GB-1 GB-1 GB-1 GB-1
G B
-1 G
B -1
G B
-1
GB-2 GB-2
GB-2
GB-2 GB-2 GB-2 GB-2 GB-2
GB-2 GB-2 GB-2
GB-2 GB-2
GB-2 GB-2 GB-2 GB-2 GB-2
G B
-2
P-2
G B
-1
GB-3
GB-3 GB-3
G B
-1
G B
-1 G
B -1
G B
-1
25.0'
19.0'
22.7'
26.0'
24.87'
26.5'
26.28'
( -5' - 4" )
23.93'
20.00'
24.00'
23.32'
25.33'
25.0'
( -5
4" )
( -5
4" )
( -5
4" ) -5' -
4"
( -5
4" )
2' -
2' -
8" )
( -2
8" )
2' -
8" )
2' -
8" )
( -2' - 0" )
SF
2' -
5' -
2' -
SF
G B
-2 G
B -2
G B
-2 G
B -2
G B
-2 G
B -2
2' -
0" )
2' -
0" )
2' -
0" )
2' -
0" )
2' -
0" )
2' -
0" )
2' -
0" )
2' -
0" )
2' -
0" )
-2
-2
2' -
0" )
2' -
0" )
2'
0"
(AT DRIVE-AISLES)
(AT DRIVE-AISLES)
(AT OPENINGS)
A1
PSB411
(AT OPENINGS)
A4
PSB411
GB-2
P-18T
P-24T
P-18TP-18T
P-18T
( -2 ' - 0
( -2 ' - 0
( -2 ' - 0
( -2 ' - 0
( -2 ' - 0
GB-1 GB-1 GB-1GB-1GB-1
P-4
-2
2'
0"
2'
0"
2'
0"
2'
0"
2'
0"
2'
0"
2'
0"
2'
0"
2'
0"
2'
0"
2' -
0" )
2' -
0" )
2' - 0" )
2' -
0" )
2' -
0" )
2' - 0" )
2' -
0" )
( -2' - 0" )
2' -
0" )
2' -
2' -
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
( -2' - 0" )
C1
PSB412
P-1M P-1 P-1M P-1M P-1M
P-1M
P-1M P-1M P-1M P-1M P-1M P-1 P-1M
P-1M P-1MP-1MP-1MP-1M
P-1M
P-1MP-1MP-1MP-1MP-1MP-1P-1MP-1M
P-1M P-1M
P-1M P-1M
P-1M
P-1M P-1M
P-1
P-1M P-1M P-1M P-1M P-1M P-1M P-1M P-1M P-1M
P-1
P-1M P-1M
P-1MP-1P-1MP-1MP-1MP-1MP-1MP-1MP-1MP-1MP-1MP-1P-1M
G B
-1
G B
-1
G B
-1
( -2 ' - 0
( -2 ' - 0
P-1
P-1
P-1M
P-1M
P-1M
P-1M P-1M
P-1MP-1M
GB-2
SF
( -2' - 0" )
GB-1
GB-1
GB-3
G B
-3
G B
-3
C3
PSB412
C3
PSB412
FD FD
FD FD
2' -
0" )
( -2' - 0" )
C4
PSB412
C4
PSB412
________________________ C4
PSB412
C4
PSB412
G B
-1 G
B -1
G B
-1 G
B -1
G B
-1
G B
-1 G
B -1
G B
-1 G
B -1
G B
-1
2' -
0" )
2' -
0" )
2'
0"
2' -
0" )
2' -
0" )
2' -
0" )
TP-4
TP-5
TP-2
TP-1
TP-3
TP-6
( -2' - 0" )
( -2 ' - 0
A1
PSB412
(TYP.)
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
1/16" = 1'-0"
F O
U N
D A
T
IO
N P
LA
N
PSB103
EHI JSC DWS
12860291
1/16" = 1'-0" (FOR PLAN NOTES AND LEGEND SEE SHEET PSB100)
FOUNDATION PLAN
NOTE:
THE PURPOSE OF THIS DRAWING IS TO SHOW THE PILE CAPS, GRADE BEAMS AND
CAST-IN-PLACE CONCRETE WALLS. FOR ADDITIONAL INFORMATION SEE SHEETS
PSB101, PSB103, PSB104 AND PSB105.
ALL UTILITIES (PIPES, CONDUITS, ETC.) BENEATH THE SLAB MUST BE
STRUCTURALLY SUPPORTED BY THE STRUCTURAL SLAB. SEE THE PLUMBING,
MECHANICAL AND ELECTRICAL DRAWINGS FOR THE APPROPRIATE MEANS OF
ATTACHMENT.
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
B
C
D
A.2
C.8
#6 AT 12" ON-
CENTER (TOP)
#4 AT 12" ON-
CENTER (BOTTOM)
#4 AT 10" ON-
CENTER (BOTTOM)
#6 AT 12" ON-
CENTER (TOP)
#6 AT 12" ON-
CENTER (TOP)
#4 AT 12" ON-
CENTER (BOTTOM)
#6 AT 12" ON-
CENTER (TOP)
#4 AT 12" ON-
CENTER (BOTTOM)
#6 AT 12" ON-
CENTER (TOP)
#4 AT 12" ON-
CENTER (BOTTOM)
#4 AT 10" ON-
CENTER (BOTTOM)
#6 AT 12" ON-
CENTER (TOP)
#4 AT 10"
ON-CENTER
(BOTTOM)
#6 AT 12" ON-
CENTER (TOP)
#6 AT 12" ON-
CENTER (TOP)
#4 AT 12" ON-
CENTER (BOTTOM)
REINFORCING
PLACEMENT
SEQUENCE
(TYP. U.O.N.)
INNER
LAYERS
O U
TE
R
LA
YE
R S
OMIT SLAB IN
THIS AREA
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
1/16" = 1'-0"
G R
O U
N D
F
LO
O R
S
LA
B R
E
IN
F O
R C
E M
E N
T P
LA
N
PSB104
EHI JSC DWS
12860292
1/16" = 1'-0" (FOR PLAN NOTES AND LEGEND SEE SHEET PSB101)
GROUND FLOOR SLAB REINFORCEMENT PLAN
NOTE:
THE PURPOSE OF THIS DRAWING IS TO SHOW THE SLAB REINFORCING REQUIREMENTS. FOR ADDITIONAL INFORMATION
SEE SHEETS PSB101, PSB103 AND PSB105.
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
B
C
D
A.2
C.8
SLOPE
RAMP UP TO LEVEL 2
NOTE L
NOTE L
0'-0"
0'-0"
0'-0"
0'-0"
FD
FD
FDFD
( -0 ' - 8
0' -
/4
( -0
5 7/8" )
( -0
7 1/4" )
( 0' - 0" )
( 0
( 0
-0
( -0' - 8" )
( -0 ' - 7
1/4" )
( -0 ' - 7
1/2" )
( 0
0" )
( 0
0" )
( -0 ' - 1
( -0 ' - 1
( -0' - 7 1/4" )
( -0' - 7 1/2" )
DOUBLE TEE FRAMING
TO LEVEL ABOVE BY
PRECAST MANUF.
(TYP. U.O.N.)
(TYP.)
0' -
8" )
( 0' - 0" ) ( 0' - 0" )
OMIT SLAB IN
THIS AREA
( -0 ' - 7
1/2" )
0'
1/
4"
( -0 ' - 2
1/4" )
( -0' - 2 1/4" )
( 0 ' - 0
( 0 ' - 0
( -0' - 0 3/8" )
( 0 ' - 0
FD
C2
PSB412
C2
PSB412
ENGINEERS + SURVEYORS
0 10'
1/16" = 1'-0" GRAPHIC SCALE
20' 40' 60'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
NEK
12/15/2022
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/P
R K
G P
3-
S .rv t
/1
1/
1:
:4
A M
1/16" = 1'-0"
G R
O U
N D
F
LO
O R
S
LA
B P
LA
N
PSB105
EHI JSC DWS
12860293
NOTE:
THE PURPOSE OF THIS DRAWING IS FOR THE DESIGN AND CONSTRUCTION OF THE CONCRETE SLAB-ON-GRADE AT THE GROUND LEVEL. THIS PLAN INDICATES THE LOCATION OF FLOOR DRAINS, SLOPES AND SLAB ELEVATIONS. THIS DRAWING MUST BE USED IN CONJUNCTION WITH SHEET PSB104. FOR ADDITIONAL INFORMATION SEE SHEETS PSB101, PSB102, PSB103 AND PSB104.
1/16" = 1'-0" (FOR PLAN NOTES AND LEGEND SEE SHEET PSB101)
GROUND FLOOR SLAB ELEVATIONS PLAN
SPEIGHT MARSHALL FRANCIS. .
STRUCTURAL ENGINEERS
SM&F Job No:WWW.SMANDF.CO
1228 PERIMETER PARKWAY, SUITE 201
P: 757.427.1020
VIRGINIA BEACH, VIRGINIA 23454
7814 CAROUSEL LANE SUITE 200
P: 804.464.4111
RICHMOND, VIRGINIA 23294
20.009-B
M O
D P
/2
M O
D P
A
N D
M O
D P
/2
PRECAST CONCRETE SHEARWALL LOAD SCHEDULE
MARK
DEAD LOAD
(KLF)
LIVE LOAD
(KLF)
SEISMIC MOMENT
(FOOT KIPS)
W-1 0.55 0 0
W-2
W-3
W-4
25 5.8 2,720
8.4 2.1 7,675
14.6 1 0
WIND SHEAR
(KIPS)
SEISMIC SHEAR
(KIPS)
WIND MOMENT
(FOOT KIPS)
3,390
PRECAST LOAD PLAN LEGEND :
X = COLUMN GRID MARK
± = APPROXIMATE DIMENSION OR ELEVATION
(FIELD VERIFY)
= COLUMN DEAD LOAD (ASSUMED)PDL
= PRECAST CONCRETE COLUMN
= PRECAST CONCRETE WALL PANEL
= COLUMN LIVE LOAD (ASSUMED)PLL
= KIPS PER LINEAR FEETKLF
= OVERTURNING MOMENT AT BASEMOT
= PRECAST CONCRETE WALL NUMBER -
SEE THE PRECAST CONCRETE WALL
LOAD SCHEDULE ON THIS SHEET
W-X
= PRECAST CONCRETE LITE WALL LW
GENERAL PRECAST LOAD PLAN NOTES :
A. FOR THE STRUCTURAL NOTES AND ABBREVIATIONS SEE SHEETS PS001, PS002 AND
PS003.
B. FOR DIMENSIONS NOT SHOWN SEE THE DIMENSION PLAN ON SHEET PSB101 AND THE
ARCHITECTURAL DRAWINGS.
C. SEE THE ARCHITECTURAL DRAWINGS FOR ADDITIONAL INFORMATION REGARDING THE
PRECAST CONCRETE SYSTEM REQUIREMENTS.
D. WALLS NOT LABELED ARE ASSUMED TO BE NON-LOAD BEARING. FOUNDATIONS HAVE
BEEN DESIGNED FOR THEIR ASSUMED SELF-WEIGHT ONLY.
E. LOADS SHOWN ON PLAN AND SCHEDULES ARE SCHEMATIC AND WERE CALCULATED BY
SPEIGHT, MARSHALL AND FRANICS, P.C. SEE 'DRIVEN PILE NOTES' NOTE #11 ON SHEET
PS001 FOR MORE INFORMATION.
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .