Attachment L - VOL4_1363603dwg8of9.pdf
PDF 296 KB Posted
- Attached to
- P475 Aircraft Maintenance Hangar
- Solicitation number
- N4008526R0148
About this file
These mechanical documents are for the P-475 Aircraft Maintenance Hangar Parking Garage project at MCAS Beaufort, South Carolina, developed by Naval Facilities Engineering Systems Command (NAVFAC). The drawings detail mechanical systems, specifically ductless split air conditioning units with three units (AC-1.7, AC-1.8, AC-1.9) serving different rooms: Solar Inverter (P103), Electrical (P104), and Sprinkler (P105). The units use R454B refrigerant, operate at 208V, and are designed for continuous 24/7 occupied mode with space temperature control set at 80°F in summer and 55°F in winter. The condensing units (CU-1.7, CU-1.8, CU-1.9) are located at grade level and have cooling capacities ranging from 10.8 to 12.2 MBH with EER ratings between 10.8 and 12.2.
The mechanical plans include specific installation notes such as routing refrigerant piping to avoid electrical equipment, providing exterior exposure corrosion protection, and implementing environmental severity classification C4 for building systems in specific rooms. The design conditions specify outdoor summer dry bulb temperature at 93°F, summer wet bulb at 78°F, and winter dry bulb at 32°F. The documents are part of a comprehensive set of mechanical drawings for a naval facility project, with modifications noted as P00005 in May 2023 and P00006/P00007 in October 2025.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A1
EF
D
TANK, THERMOSTAT
SWITCH, SOFT WATER
STATIC PRESSURE, SPRINKLER PIPE
REGISTER/REGULATING
ROTATIONS PER MINUTE
SOIL
OPPOSED BLADE DAMPER
TEMPERATURE
SQUARE
REQUIRED
REFERENCE
PRESSURE
PHASE
OPERATING
EXH
FA
ESP
ENT
ENCL
ELEV
EFF
ELEC
DW
ECD
EF
EAT
EA
DWG
DDC
DEG
DB
DC
CONN
CENT
EXHAUST
FIRE ALARM
EXTERNAL STATIC PRESSURE
ENCLOSE (ENCLOSURE)
ENTERING
EFFICIENCY
ELEVATION
ELECTRIC
NO.
NO
NC
MIN
MD
NOISE CRITERIA/NORMALLY CLOSED
NORMALLY OPEN/NITROUS OXIDE
NUMBER
MANUAL DAMPER
MINIMUM
TEMP
T
SW
DOMESTIC WATER (PLUMBING)
ENTERING AIR TEMPERATURE
ELECTRIC CONTROL DAMPER
EXHAUST FAN
EXHAUST AIR
DRAWING
DIRECT DIGITAL CONTROL
DIGITAL CONTROLLER
DEGREE
DRY BULB
LED
MAX
M
KW
HZ
CONNECTION
CENTRIFUGAL
HVAC
HP
HOR
HOA
LIGHT EMITTING DIODE
MAXIMUM
METER
HERTZ (CYCLES PER SECOND)
KILOWATT
SQ
SP
S
HEATING/VENTILATING/AIR CONDITIONING
HORSEPOWER, HEAT PUMP
HAND-OFF-AUTOMATIC
HORIZONTAL
RPM
REQD
REG
REF
CAP
BC
BDD
AUTO
ATC
AD
HVAC
AUTOMATIC TEMPERATURE CONTROL
ACCESS DOOR, AIR DRYER, AREA DRAIN
BACK DRAFT DAMPER
BUILDING CONTROLLER
CAPACITY
AUTOMATIC
G
FFE
FL
DESIGNATION
GRILLE, GRAMS
FINISHED FLOOR ELEVATION
FLOOR(ING)
PH
PRESS
OPER
OBD
DESIGN CONDITIONS
VOLUME DAMPER
OUTDOOR:
VD
SUMMER DRY BULB
SUMMER WET BULB (MCWB)
WINTER DRY BULB
93° F
32° F
78° F
WELDED WIRE FABRICWWF
GRILLE MARK
DIFFUSER, REGISTER,
BUILDING DESIGNATOR
EQUIPMENT MARKSCHEDULE REFERENCE
AIR QUANTITY
TYPE
GENERAL IDENTIFICATION
NOTE:
REFER TO FLOOR PLANS AND DETAILS
FOR EXTENT OF ABBREVIATIONS USED.
EQUIPMENT TYPE
PLUMBINGPL
STAINLESS STEELSST
HVAC DESIGNATION
WET BULBWB
GENERAL NOTES
1. REFER TO DIVISION 23 SPECIFICATIONS FOR ALL PIPING
CONSTRUCTION AND INSTALLATION REQUIREMENTS.
2. REFER TO MECHANICAL FLOOR PLANS FOR THERMOSTAT
AND TEMPERATURE SENSOR LOCATIONS.
3. MOUNT ROOM THERMOSTATS/SENSORS AT 48" AFF.
4. PIPING LOCATIONS SHOWN ARE COORDINATED IN THE
DESIGN DRAWINGS, VARIATIONS FROM DESIGN ARE
POSSIBLE. REFER TO SPECIFICATIONS FOR SHOP DRAWING
REQUIREMENTS. DO NOT PROCEED WITH INSTALLATION OF
PIPING UNTIL APPROVED SHOP DRAWINGS ARE AVAILABLE
AT THE SITE.
RADIANT GAS HEATERRGH
DESIGNATIONDUCTWORK
12X6
THERMOSTAT/TEMPERATURE SENSOR
RECTANGULAR DUCT, FIRST
FIGURE IS SIDE SHOWN
STANDARD BRANCH TAKEOFF
DESIGNATIONDUCTWORK
SUPPLY AIR DUCT - SECTION
ELBOW TURNED UP
ELBOW TURNED DOWN
RETURN AIR DUCT - SECTION
EXHAUST AIR DUCT - SECTION
24Ø
TRANSITION - ECCENTRIC
DUCT ACCESS DOOR
TOP/SIDE/BOTTOM
ROUND DUCT, DIAMETER SHOWN
TRANSITION - CONCENTRIC
RECTANGULAR/SQUARE TO ROUND
DUCT TRANSITION
TEE TURNED UP
TEE TURNED DOWN
MANUAL DAMPER - SINGLE
LEAF TYPE
MANUAL DAMPER - OPPOSED BLADE
TYPE (UNLESS NOTED OTHERWISE)
MOTOR ACTIVATED CONTROL DAMPER
OFFSET IN DUCTWORK - UP
UP
OFFSET IN DUCTWORK - DOWNDN
NOTE: REFER TO FLOOR PLANS AND DETAILS FOR
EXTENT OF SYMBOLS AND ABBREVIATION USED.
T
TURNING VANES - SQUARE ELBOW
OUTSIDE AIR DUCT - SECTION
DX SPLIT AIR CONDITIONING UNIT SCHEDULE
MARK LOCATION
TOTAL
(MBH)
AIR
QUANTITY
(CFM) DB WB
COOLING CAPACITY
EER COP FLAPHASE REMARKS
MOTOR
SENSIBLE
(MBH)
ENT. AIR (°F)
HEATING CAPACITY
ENT
AIR (°F)
ELEC
RESIST
(KW)
HEAT
PUMP
(MBH) VOLTS
GENERAL NOTES:
1. UNIT PERFORMACE IS A COMBINED RATING OF EACH AC UNIT WITH THE CONNECTED CONDENSING UNIT.
2. PROVIDE UNITS WITH INTEGRAL CONDENSATE PUMP.
AC-1.8 P104 ELEC 78 65 3.1 0.61 -70-9.2 208
AC-1.7 810P103
SOLAR INV
78 65 10.8 2.5 -70-22.4 0.61208
11335 8 12.2
34 24
AC-1.9 P105 SPKLR 78 65 3.1 0.61 -70-9.2 20811335 8 12.2
CONDENSING UNIT SCHEDULE
RELATED
EQUIPMENT
AMB TEMP
(°F) REMARKSVOLTS
TOT CAP
(MBH)LOCATION PHASE
ELECTRICAL
MARK
COOLING
HERTZ
EER
RATING REFRIGERANTMCA MOP
CU-1.8 GRADE 11 AC-1.8 -208 1 60 12.2 R454B
CU-1.7 GRADE 34 AC-1.7 -208 1 60 10.8 R454B2598
98 11 15
HEATING
CAPACITY
9.2
22.4
CU-1.9 GRADE 11 AC-1.9 -208 1 60 12.2 R454B98 11 159.2
J O
H N
E DW A RD
B A L L
PROF E
SS I ON A L E N
G I
N E E R
E L I
C N S E
STATE OF
R F L O I D A
No. 66893
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
ALG
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ga r_ P ar ki ng F ac ili ty _M
E -v
.rv t
/5
/2
8:
:5
A
M
NOT TO SCALE
P A
R K
IN
G
G A
R A
G E
M
E C
H A
N
IC
A L
N O
T E
S , S
Y M
B O
LS
, A
N D
S C
H E
D U
LE
S
PMH001
MAB MAB JEB
12860390
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
TT
T
P102
UNDEFINED
7 9 10
C
D
C.8
P104
ELEC
P103
SOLAR INV
AC
1.7
CU
1.7
AC
1.8
CU
1.8
RL
RS
1"ø D
RL
RS
5 6
A
B
A.2
P105
SPKLR
AC
1.9
RS
RL
CU
1.9
1" ø
D
J O
H N
E DW A RD
B A L L
PROF E
SS I ON A L E N
G I
N E E R
E L I
C N S E
STATE OF
R F L O I D A
No. 66893
ENGINEERS + SURVEYORS
KEY NOTES 00
SHEET NOTES:
NOTES:
0 5'
1/8" = 1'-0" GRAPHIC SCALE
10' 20' 30'
N
PLAN
NORTH
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
ALG
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ga r_ P ar ki ng F ac ili ty _M
E -v
.rv t
/5
/2
8:
:5
A
M
1/8" = 1'-0"
P A
R K
IN
G
G A
R A
G E
G
R O
U N
D F
LO
O
R M
E C
H A
N
IC
A L
P
LA
N
A R
E A
B
PMH101B
MAB MAB JEB
12860391
1/8" = 1'-0" A3
GROUND FLOOR MECHANICAL PLAN, AREA B
A. REFER TO SYMBOLS, ABBREVIATIONS, AND
GENERAL NOTES ON SHEETS PMH001.
B. DO NOT ROUTE REFRIGERANT OR DRAIN
PIPING OVER ELECTRICAL EQUIPMENT. REFER
TO ELECTRICAL DRAWINGS FOR EQUIPMENT
LOCATIONS. - TYPICAL.
C. PROVIDE EXTERIOR EXPOSURE CORROSION
PROTECTION AND CONTROL IN ACCORDANCE
WITH AN ENVIRONMENTAL SEVERITY
CLASSIFICATION (ESC) OF C4 FOR BUILDING
SYSTEMS AND COMPONENTS IN THE
FOLLOWING ROOMS: STAIR 1, STAIR 2, STAIR 3,
STAIR 4, P103 SOLAR INV, P104 ELEC, P105
SPKLR, AND PV CANOPY.
A B
KEYPLAN
1 SIZE REFRIGERANT LIQUID AND SUCTION
PIPING PER APPROVED MANUFACTURER'S
REQUIREMENTS. ROUTE PIPING TO AVOID ALL
ELECTRICAL PANELS AND EQUIPMENT WITHIN
THE ROOM. - TYPICAL.
1 SIZE REFRIGERANT LIQUID AND SUCTION
PIPING PER APPROVED MANUFACTURER'S
REQUIREMENTS. ROUTE PIPING TO AVOID ALL
ELECTRICAL PANELS AND EQUIPMENT WITHIN
THE ROOM. - TYPICAL.
2 1" DRAIN PIPING DOWN TO AREA DRAIN. REFER
TO PLUMBING DRAWING FOR LOCATION.
3 ROUTE 1" DRAIN PIPING TO EXTERIOR.
TERMINATE WITH GOOSENECK.
1/8" = 1'-0" B1
GROUND FLOOR MECHANICAL PLAN, AREA B
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
TSAIR CONDITIONING UNIT
CONDENSING UNIT
J O
H N
E DW A RD
B A L L
PROF E
SS I ON A L E N
G I
N E E R
E L I
C N S E
STATE OF
R F L O I D A
No. 66893
ENGINEERS + SURVEYORS
1 2 3 4 5
3 4 5
D
C
B
A
SHEET OF
NAVFAC DRAWING NO.
CONSTR. CONTR. NO.
EPROJECT NO.:
SCALE:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y
P -4
A
IR
C
R A
F T
M A
IN
T
E N
A N
C E
H A
N G
A R
V
O
LU
M E
P A
R K
IN
G
G A
R A
G E
O P
T
IO
N
D C
C O
R E
B E
A U
F O
R T
, S C
N O
R F
O
LK
, V A
N A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A
V A
L F
A C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
T E
M S
C O
M M
A N
D
M
ID
-A T
LA
N
T
IC
M C
A S
B E
A U
F O
R T
FP ENGINEER
CHIEF ENG/ARCH
BRANCH MANAGER
PM/DM
DES DRW CHK
SATISFACTORY TO DATE
ACTIVITY
FOR COMMANDER NAVFAC
APPROVED
A/E INFO
SEAL
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1363603
DRAWFORM REVISION: 25 AUGUST 2020
NOTE:
IF THIS DRAWING IS LESS THAN 34" X 22"
IT IS A REDUCED SIZE DRAWING
D
C
B
A
1 2
KTB / RLH
Approved by J. Scott Roberts, Asset Management Branch Head &
Supervisory Facility Planner, PWD
Beaufort, SC via email.
EJA
DSN
ALG
12/15/2022
A ut od es k D oc s:
//2
V
M F
A T
F
M ai nt en an ce
H an ga r/2
F
M ai nt H an ga r_ P ar ki ng F ac ili ty _M
E -v
.rv t
/5
/2
8:
:5
A
M
NOT TO SCALE
P A
R K
IN
G
G A
R A
G E
C
O N
T R
O L
D
U C
T
LE
S S
S P
LI
T
S Y
S T
E M
PMI701
MAB MAB JEB
12860392
RLF SYS #12
DUCTLESS SPLIT SYSTEM SEQUENCE OF OPERATION
THE CONTROL SEQUENCES ARE BY THE EQUIPMENT MANUFACTURER. SETTINGS ARE THROUGH
THE SPACE SENSOR.
SAFETIES
THE SYSTEM SHALL RUN SUBJECT TO THE UNIT MANUFACTURER’S SAFETIES.
SPACE TEMPERATURE CONTROL
OCCUPIED MODE 24 HOURS / DAY 7 DAYS A WEEK.
WHEN ENABLED THE SYSTEM HARDWARE SHALL MAINTAIN SPACE TEMPERATURE AT THE
CONFIGURED SETPOINT.
NOT TO SCALE
C3
DUCTLESS SPLIT SCHEMATIC
A. CONTROLS AND SPACE SENSORS BY DUCTLESS SPLIT
MANUFACTURER.
AC-1.9 P105 SPKLR P105 SPKLR 80 55
AC-1.8 P104 ELEC P104 ELEC 80 55
AC-1.7 P103 SOLAR INV P103 SOLAR INV 80 55
EQUIPMENT
IDENTIFIER
SPACES SERVED (ROOM
NAME #)
SENSOR LOCATION
(ROOM NAME #)
SUMMER ZONE
TEMPERATURE
(DEGREE F)
WINTER ZONE
TEMPERATURE
(DEGREE F)
DUCTLESS SPLIT SPACE SENSOR SCHEDULE
M
O D
P
/2
M
O D
P
A N
D M
O D
P
/2
| MECHANICAL |
| PMH001 - PARKING GARAGE - MECHANICAL NOTES, SYMBOLS, AND SCHEDULES |
| PMH101B - PARKING GARAGE - GROUND FLOOR MECHANICAL PLAN - AREA B |
| PMI701 - PARKING GARAGE - CONTROL - DUCTLESS SPLIT SYSTEM |
2025-11-05T15:25:53-0500
2025-11-05T15:26:18-0500
2025-11-05T15:26:18-0500
2025-11-22T16:25:16-0500
2025-11-22T16:25:43-0500
2025-11-22T16:25:16-0500
2025-11-22T16:25:17-0500
2025-11-22T16:25:43-0500
2025-11-22T16:25:43-0500