Attachment L - Emerson EMS Inspection Report.pdf

PDF 5 MB Posted

Attached to
27-0052 FMP Series 6 Roof Replacement for Cass Tech, Emerson
Solicitation number
RFP DET 270000000151 1
Issued by
Wayne County, Detroit City, Michigan

About this file

This is a roof inspection report for Ralph W. Emerson Elementary/Middle School in Detroit, Michigan, prepared by Detroit Public Schools on June 10, 2026, following a visual inspection conducted on May 12, 2026. The inspection evaluated the remaining service life of the existing roof systems across 31 distinct roof areas (A through EE) to inform replacement planning and budgeting decisions. The report identifies that roof areas installed in 2017 utilize fully-adhered TPO membrane systems, while older roof areas installed prior to 1999 consist of 4-ply hot asphalt with aggregate surfaces, smooth 4-ply with aluminum coating, or in one case a 2019-installed EPDM membrane. The inspection reveals widespread deterioration issues including ponding water caused by inadequate slope, wet cores indicating moisture intrusion, membrane splits and holes, open flashing, and severe membrane deterioration. The report does not specify response dates, due dates, site visits, or bidder meetings, as it is a diagnostic inspection document rather than a solicitation notice.

The report recommends full roof replacement for 24 roof areas (E, F, G, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Z, AA, BB, CC, DD, and EE) with removal down to the structural steel deck and installation of R-30 insulation systems with fully-adhered 60-mil EPDM membranes eligible for 20-year warranties, at an estimated construction cost of $675,000. An additional six roof areas (A, B, C, D, H, and Y) are recommended for aggressive preventative maintenance at an estimated cost of $10,000. The total estimated construction cost for all recommended work is $685,000. The report serves as supporting documentation for the related state and local contract opportunity 27-0052 FMP Series 6 Roof Replacement for Cass Tech and Emerson facilities in Michigan.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Detroit Public Schools – Ralph W. Emerson

Elementary/Middle School 18240 Huntington Road

Detroit, MI 48219

June 10, 2026

Detroit Public Schools – Ralph W. Emerson Elementary/Middle School

Table of Contents

Executive Summary Page 3

Roof Plan Page 4

Roof Area Descriptions Page 5

Roof Area Photos Page 16

EXECUTIVE SUMMARY

On May 12, 2026 a visual inspection of the existing roof system was performed. The purpose of this inspection was to determine the estimated surface life left of the existing roof system. Roof

Areas A, B, C, D, E, H, I, J, K, L, M, N, O & Z existing systems consisted of a fully-adhered TPO.

Roof Areas F, G, P, Q, S, T, W, X, Y, AA, BB, CC & EE existing systems consisted of a 4-ply in hot asphalt with an aggregate surface system installed prior to 1999. Roof Area R existing system consisted of a fully-adhered 45-mil EPDM roof membrane installed in 2019. Roof Areas U, V, & DD existing system consisted of the smooth surface 4-ply with a aluminum coating, installed prior to

1999.

Note: TPO areas are failing due to ponding water caused by lack of slope. Many of the cores taken were wet.

Recommendations:

Roof Areas E, F, G, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Z, AA, BB, CC, DD & EE: Remove existing roof systems system down to the structural steel deck. Install a R-30 Insulation system with a fully-adhered 60-mil EPDM membrane. This system is eligible for a 20 year warranty.

Roof Areas A, B, C, D, H & Y: Aggressive preventative maintenance

Estimated Construction Costs:

Roof Areas E, F, G, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Z, AA, BB, CC, DD & EE: Full replacement with a R-30 Insulation System with a fully-adhered 60-mil EPDM: $675,000.00

Roof Areas A, B, C, D, H & Y: Aggressive preventative maintenance $10,000.00

ROOF PLAN:

Note: Remaining life of existing roof systems is based on the estimated age of the roofs, visual inspection and assuming no maintenance being performed. Preforming repairs to roof areas that are red will not add any years to the roof life. It will only stop the current problem.

ROOF AREA DESCRIPTIONS:

Roof Area ID: A

Size: 3,100 sf.

Year Installed: 2017

Height: 30 ft

Structural Slope: None

Drainage: Roof Drain

Roof Area ID: B

Size: 4,143 sf.

Year Installed: 2017

Height: 32 ft

Drainage: Eave Edge

Roof Area ID: C

Size: 5,024 sf.

Year Installed: 2017

Height: 30 ft

Roof Area ID: D

Size: 1,751 sf.

Year Installed: 2017

Height: 20 ft

Roof Area ID: E

Size: 1,625 sf.

Year Installed: 2017

Height: 27 ft

Roof Area ID: F

Size: 1,231 sf.

Year Installed: Pre 1999

Height: 155 ft

Structural Slope: 1/8-Inch

Roof Area ID: G

Size: 65 sf.

Year Installed: Pre 1999

Height: 16 ft

Roof Area ID: H

Size: 2,399 sf.

Year Installed: 2017

Height: 22 ft

Roof Area ID: I

Size: 3,672 sf.

Year Installed: 2017

Height: 30 ft

Roof Area ID: J

Size: 2,832 sf.

Year Installed: 2017

Height: 32 ft

Drainage: Eave

Roof Area ID: K

Size: 3,000 sf.

Year Installed: 2017

Height: 30 ft

Roof Area ID: L

Size: 3,176 sf.

Year Installed: 2017

Height: 32 ft

Roof Area ID: M

Size: 2,250 sf.

Year Installed: 2017

Height: 30 ft

Roof Area ID: N

Size: 2,488 sf.

Year Installed: 2017

Height: 30 ft

Roof Area ID: O

Size: 2,514 sf.

Year Installed: 2017

Height: 30 ft

Roof Area ID: P

Size: 1,251 sf.

Year Installed: Pre 1999

Height: 12 ft

Drainage: Roof Drains

Roof Area ID: Q

Size: 3,405 sf.

Year Installed: Pre 1999

Height: 20 ft

Drainage: Roof Drains

Roof Area ID: R

Size: 404 sf.

Year Installed: 2017

Height: 12 ft

Roof Area ID: S

Size: 418 sf.

Y Year Installed: Pre 1999

Height: 15 ft

Drainage: Gutter

Roof Area ID: T

Size: 102 sf.

Year Installed: Pre 1999

Height: 12 ft

Roof Area ID: U

Size: 288 sf.

Year Installed: Pre 1999

Height: 15 ft

Roof Area ID: V

Size: 288 sf.

Year Installed: Pre 1999

Height: 15 ft

Roof Area ID: W

Size: 165 sf.

Year Installed: Pre 1999

Height: 12 ft

Roof Area ID: X

Size: 555 sf.

Year Installed: Pre 1999

Height: 12 ft

Roof Area ID: Y

Size: 68 sf.

Year Installed: Pre 1999

Height: 37 ft

Roof Area ID: Z

Size: 112 sf.

Year Installed: 2017

Height: 37 ft

Roof Area ID: AA

Size: 304 sf.

Year Installed: Pre 1999

Height: 15 ft

Roof Area ID: BB

Size: 440 sf.

Year Installed: Pre 1999

Height: 15 ft

Roof Area ID: CC

Size: 102 sf.

Year Installed: Pre 1999

Height: 12 ft

Structural Slope: 1/8

Roof Area ID: DD

Size: 186 sf.

Year Installed: Pre 1999

Height: 15 ft

Roof Area ID: EE

Size: 418 sf.

Year Installed: Pre 1999

Height: 15 ft

ROOF AREA PHOTOS:

Ponding water due to lack of slope

Hole caused by fire on roof

Hole caused by fire on roof

Open flashing

Split in drain pan flashing

Severe membrane deterioration

Split in drain pan flashing Open flashing lap

Open flashing lap

Membrane deterioration

Water behind flashing Membrane holes

File details come from the government source that posted it. Updated .