Attachment J - Cass Tech HS Inspection Report.pdf

PDF 3 MB Posted

Attached to
27-0052 FMP Series 6 Roof Replacement for Cass Tech, Emerson
Solicitation number
RFP DET 270000000151 3
Issued by
Wayne County, Detroit City, Michigan

About this file

This is a Cass Tech High School Inspection Report prepared for the Michigan state and local contract opportunity 27-0052 FMP Series 6 Roof Replacement for Cass Tech and Emerson facilities. The inspection report documents the existing conditions of the roof systems at Cass Tech High School, providing a comprehensive assessment of structural integrity, material conditions, and areas requiring remediation. The report serves as a supporting document for bid preparation and scope of work development, enabling contractors to understand the current state of the roofing systems and the extent of replacement or repair work necessary to meet project requirements.

The inspection report functions as a technical assessment tool to inform project specifications and contractor estimating. As a supporting exhibit to the solicitation, the report provides detailed findings that establish the baseline conditions for the roof replacement project, allowing bidders to develop accurate proposals and timelines. The document supports the competitive bidding process by ensuring all potential contractors have access to the same technical information regarding existing roof conditions, material types, and structural considerations that will influence project execution and cost estimation.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Detroit Public Schools – Cass Technical Hich School

2501 2nd Ave.

Detroit, MI 48201

June 10, 2026

Detroit Public Schools – Cass Technical Hich School

Table of Contents

Executive Summary Page 3

Roof Plan Page 4

Roof Area Descriptions Page 5

Roof Area Photos Page 14

EXECUTIVE SUMMARY

On April 24, 2026 a visual inspection of the existing roof system was performed. The purpose of this inspection was to determine the estimated surface life left of the existing roof system. All roof were installed in 2003/2004. Roof Areas A-S existing systems consisted of a granule surface modified bitumen roof membrane which was coated in 2021 with a rubberized asphalt coating. Roof

Areas T, U, V & W existing system consisted of the original granule surface modified bitumen roof membrane. Roof Areas X & Y consisted of an existing metal panel standing seam roof system.

Note: All cores that were taking were wet and shoed signs of moisture.

Observations & Recommendations:

Roof Areas A-W: Remove existing roof systems system down to the structural steel deck. Install a

R-30 Insulation system with a fully-adhered 60-mil EPDM membrane. This system is eligible for a

20 year warranty.

Roof Areas X & W: No action required at this time

Estimated Construction Costs:

Full replacement with a R-30 Insulation System with a fully-adhered 60-mil EPDM: $2,482,00.00

ROOF PLAN:

Note: Remaining life of existing roof systems is based on the estimated age of the roofs, visual inspection and assuming no maintenance being performed.

ROOF AREA DESCRIPTIONS:

Roof Area ID: A

Size: 11,007 sf.

Year Installed: 2003/2004

Height: 95 ft

Structural Slope: None

Drainage: Roof Drains

Roof Area ID: B

Size: 1,800 sf.

Year Installed: 2003/2004

Height: 75 ft

Roof Area ID: C

Size: 18,360 sf.

Year Installed: 2003/2004

Height: 75 ft

Roof Area ID: D

Size: 915 sf.

Year Installed: 2003/2004

Height: 75 ft

Drainage: Eave

Roof Area ID: E

Size: 465 sf.

Year Installed: 2003/2004

Height: 77 ft

Roof Area ID: F

Year Installed: 2003/2004

Height: 77 ft

Roof Area ID: G

Size: 435 sf.

Year Installed: 2003/2004

Height: 85 ft

Drainage: Roof Drain

Roof Area ID: H

Size: 2,399 sf.

Year Installed: 2003/2004

Height: 55 ft

Roof Area ID: I

Size: 8,649 sf.

Year Installed: 2003/2004

Height: 45 ft

Roof Area ID: J

Size: 1,620 sf.

Year Installed: 2003/2004

Height: 45 ft

Roof Area ID: K

Size: 338 sf.

Year Installed: 2003/2004

Height: 60 ft

Roof Area ID: L

Size: 492 sf.

Year Installed: 2003/2004

Height: 53 ft

Roof Area ID: M

Size: 3,960 sf.

Year Installed: 2003/2004

Height: 70 ft

Roof Area ID: N

Size: 4,758 sf.

Year Installed: 2003/2004

Height: 35 ft

Roof Area ID: O

Size: 338 sf.

Year Installed: 2003/2004

Height: 53 ft

Roof Area ID: P

Size: 370 sf.

Year Installed: 2003/2004

Height: 40 ft

Roof Area ID: Q

Year Installed: 2003/2004

Height: 40 ft

Roof Area ID: R

Size: 937 sf.

Year Installed: 2003/2004

Height: 40 ft

Roof Area ID: S

Size: 2,534 sf.

Year Installed: 2003/2004

Height: 40 ft

Roof Area ID: T

Size: 1,185 sf.

Year Installed: 2003/2004

Height: 12 ft

Structural Slope: 1/8-inch

Roof Area ID: U

Size: 1,197 sf.

Year Installed: 2003/2004

Height: 12 ft

Roof Area ID: V

Size: 2,534 sf.

Year Installed: 2003/2004

Height: 15 ft

Roof Area ID: W

Size: 1,240 sf.

Year Installed: 2003/2004

Height: 15 ft

Roof Area ID: Y

Size: 15,500 sf.

Year Installed: 2003/2004

Height: 50 ft

Structural Slope: 8:12

Roof Area ID: X

Size: 9000 sf.

Year Installed: 2003/2004

Height: 90 ft

Structural Slope: 8:12

ROOF AREA PHOTOS:

Membrane blisters Membrane blisters

Active leak Open flashing

Overview

Existing wall ladder – Needs to be replaced

Open flashing Overview

Vegetation growing on roof

Existing repairs made to drain sump/membrane blisters

File details come from the government source that posted it. Updated .