Attachment J-1 DWGS.pdf
PDF 6 MB Posted
- Attached to
- GPO G-Street Sidewalk Repair
- Solicitation number
- 040ADV-26-R-0010
- Issued by
-
Government Publishing Office
About this file
This document is a complete set of 100% construction documents for G Street Sidewalk Repairs at the U.S. Government Publishing Office located at 732 North Capitol Street NW, Washington, DC 20401. The project, prepared by Gale Associates, Inc. and Dewberry Engineers Inc., encompasses comprehensive repair and renovation work for the sidewalk vault structure and associated site improvements.
The scope of work includes removal and replacement of concrete sidewalks, structural concrete slab repairs with supplemental reinforcement, masonry and brownstone facade repairs with mortar joint repointing, waterproofing system installation, new concrete wear courses with proper slope matching existing conditions, ADA-compliant concrete ramps and stair landings with metal railings, concrete gutters and curbs, removal and reinstallation of existing pavers and granite curbs, and ductwork modifications. Construction details specify Class E concrete per 2020 DDOT Standards (3500 PSI compressive strength, 0-3 inch slump, 4X4 W2.9XW2.9 wire fabric reinforcement, and control joints at 36-inch spacing). The contractor must coordinate manufacturer technical representatives for quality assurance site visits, provide temporary protective structures over through-slab repairs, and schedule work according to owner phasing requirements involving overnight work. Special inspections are required for concrete placement, reinforcing bar installation, and welded connections. The documents include detailed architectural and civil drawings depicting existing conditions, demolition plans, new construction plans, partial elevations, typical sidewalk details, structural slab repair sequences, and stone/mortar joint repair procedures across 25 drawing sheets.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 040ADV-26-R-0010.pdf | ||
| Attachment J-4 -Cost-Price Proposal.xlsx | XLSX spreadsheet | |
| Attachment J-2 G-Street Sidewalk Repair Spec.pdf | ||
| Attachment J-3 - Past Performance Questionnaire.doc | DOC document | |
| Attachment J-5 DBA Wage Determination Washington DC.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DRAWING NO TITLE
G-001 COVER SHEET
G-002 STANDARD ABBREVIATIONS, LEGEND, SYMBOLS AND GENERAL NOTES
G STREET SIDEWALK REPAIRS
A-502 A-503
A-501
PREPARED FOR
A-505 A-506
A-504
UNITED STATES GOVERNMENT PUBLISHING OFFICE
US GOVERNMENT PUBLISHING OFFICE
732 NORTH CAPITOL STREET, NW
WASHINGTON, DC 20401
LOCATION MAP
A-102
A-301
SIDEWALK PLAN - EXISTING CONDITIONSA-101
G-001
COVER
SHEET
NONE
VICINITY MAP
A-507
A-103
SIDEWALK PLAN - NEW CONSTRUCTION
100% CONSTRUCTION DOCUMENTS
A-104 A-105
A-508
A-512
SIDEWALK PLAN - EXISTING CONDITIONS
SIDEWALK REFLECTED CEILING PLAN - EXISTING CONDITIONS
SIDEWALK PLAN - NEW CONSTRUCTION
PARTIAL ELEVATIONSA-201
TYPICAL CROSS SECTIONS
TYPICAL DETAILS - EXISTING CONDITIONS
DETAILS - EXISTING CONDITIONS
DETAILS - EXISTING CONDITIONS
DETAILS - EXISTING CONDITIONS
DETAILS - NEW CONSTRUCTION
DETAILS - NEW CONSTRUCTION
DETAILS - NEW CONSTRUCTION
TYPICAL DETAILS - STRUCTURAL CONCRETE SLAB REPAIRS
DETAILS - EXISTING CONDITIONS
A-509 DETAILS - NEW CONSTRUCTION
A-510 DETAILS - NEW CONSTRUCTION
A-511 DETAILS - NEW CONSTRUCTION
ARCHITECTURAL DRAWINGS
DRAWING NO TITLE
C001 COVER SHEET
C002 EXISTING CONDITIONS
DEMOLITION PLANC003
EROSION AND SEDIMENT CONTROL PLAN
SITE PLAN
SEE DETAILS
TEMPORARY TRAFFIC CONTROL PLAN
TEMPORARY TRAFFIC CONTROL DETAILS
CIVIL DRAWINGS
EROSION AND SEDIMENT CONTROL DETAILS
EROSION AND SEDIMENT CONTROL NOTES
C004 C005 C006 C007 C008 C009 C010
S-501
TYPICAL DETAILS - STONE AND MORTAR REPAIRS
G-003 GENERAL NOTES CONTINUED
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
G 0X
.D W
G
• 4
/22 /20
3:
:56
P M
M
LF
656429 G0x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
APRIL 5, 2024
WORK AREA PLANA-100
G-004 GENERAL NOTES CONTINUED
A500
DETAIL NUMBER
SHEET WHERE
DETAIL IS SHOWN
A300 S
SECTION IDENTIFIER
SHEET WHERE
SECTION IS SHOWN
A200 E
ELEVATION IDENTIFIER
SHEET WHERE
ELEVATION IS SHOWN
DETAIL INDICATORS
SECTION INDICATOR
ELEVATION INDICATOR
CONCRETE
NOTE: NOT ALL SYMBOLS NECESSARILY USED
NOTE: NOT ALL HATCH PATTERNS NECESSARILY USED
EX
EXISTING CONDITION
IDENTIFIER.
EX
EXISTING CONDITION
IDENTIFIER.
STANDARD SYMBOLS
STANDARD HATCH PATTERNS
GENERAL NOTES
G-002
STANDARD
ABBREVIATIONS,
LEGEND, SYMBOLS
AND
GENERAL NOTES
NONE
CMU
STONE
BRICK
STONE/GRAVEL
EARTH/SOIL
LANDSCAPING
DEMOLITION NOTES
1. THE INFORMATION SHOWN ON THE DRAWINGS HAS BEEN COMPILED FROM VARIOUS SOURCES, AND MAY NOT REFLECT THE ACTUAL CONDITIONS
AT THE TIME OF CONSTRUCTION.
2. THE CONTRACTOR SHALL COMPLY WITH ALL FEDERAL, STATE, AND LOCAL LAWS AND REQUIREMENTS PERTAINING TO THIS PROJECT.
3. JOB SITE SAFETY IS THE CONTRACTOR'S RESPONSIBILITY. GALE REPRESENTATIVES, INCLUDING SUBCONSULTANTS RETAINED BY GALE, MAY VISIT THE JOB SITE FROM TIME TO TIME. THESE VISITS ARE FOR CLARIFICATIONS OF SPECIFIC DESIGN RELATED ISSUES ONLY AND ARE NOT FOR THE PURPOSES OF JOB SITE SAFETY. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO COMPLY WITH ALL SITE SAFETY APPLICABLE REQUIREMENTS.
4. THE BUILDING MAY BE OCCUPIED DURING CONSTRUCTION. IN NO CASE SHALL WORK BE COMPLETED OVER BUILDING OCCUPANTS. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO INTERIOR ELEMENTS AND TO PROTECT OCCUPANTS.
COORDINATE AND SCHEDULE WORK LOCATIONS IN ADVANCE WITH THE OWNER. SCHEDULE AND EXECUTE WORK TO MINIMIZE NOISE
INTERRUPTIONS.
5. CONTRACTOR SETUP LOCATIONS SHALL BE AS INDICATED BY THE OWNER DURING THE PRE CONSTRUCTION MEETING.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SEGREGATING THE WORK AREA IMMEDIATELY BELOW AND ADJACENT TO THE WORK AREA. THE CONTRACTOR SHALL COVER ALL INTERIOR ITEMS INCLUDING FLOORS AND EQUIPMENT PRIOR TO DEMOLITION. ONCE REMOVAL IS COMPLETE FOR THE DAY, THE PLASTIC COVERINGS SHALL BE REMOVED AND THE INTERIOR AREAS CLEANED. CLEANING SHALL INCLUDE, BUT NOT BE LIMITED TO, SWEEPING OF FLOORS AND DUST REMOVAL FROM THE TOPS OF LIGHT FIXTURES AND EQUIPMENT WHERE ACCESSIBLE.
7. REMOVE AND DISPOSE OF EXISTING ASSOCIATED MATERIALS DOWN TO THE STRUCTURAL SLAB WHERE INDICATED UNLESS OTHERWISE INDICATED ON THE DETAIL DRAWINGS TO REMAIN. REMOVE AND DISPOSE OF ALL ITEMS SCHEDULED TO BE REMOVED.
8. REMOVALS SHALL BE PERFORMED IN ACCORDANCE WITH THE SUBMITTED AND APPROVED REMOVAL PLAN, THE DETAIL DRAWINGS AND
SPECIFICATIONS.
9. NO DEMOLITION WORK SHALL PROCEED UNTIL A PLAN HAS BEEN SUBMITTED TO AND APPROVED BY THE OWNER AND ENGINEER DETAILING THE METHODS AND EQUIPMENT TO BE USED TO DEMOLISH AND/OR SURFACE PREPARE STRUCTURES AND FEATURES.
10. ALL DEMOLISHED MATERIALS AND DEBRIS SHALL BE LEGALLY DISPOSED OF OFF SITE IN A MANNER SATISFACTORY TO THE OWNER AND CURRENT
DEP/EPA REQUIREMENTS.
11. NO DEMOLITION WORK SHALL BEGIN UNTIL THE TEMPORARY SHORING IS INSTALLED AT EACH LEVEL OF THE GARAGE.
REPLACEMENT NOTES
1. FOR THE SAKE OF CLARITY, EACH INDIVIDUAL DETAIL ON THE FLOOR AND REFLECTED CEILING PLANS HAS NOT BEEN INDICATED. EXISTING AND
NEW DETAILS HAVE BEEN INDICATED FOR TYPICAL COMPONENTS AT RANDOM LOCATIONS.
2. COMPONENTS SHOWN ON THE DETAIL DRAWINGS SHALL BE NEW UNLESS SPECIFICALLY INDICATED AS EXISTING.
3. ITEMS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT.
4. ANY DISCREPANCIES ON THE DRAWINGS NOTED BY THE CONTRACTOR SHALL BE BROUGHT TO THE OWNERS ATTENTION PRIOR TO BID
SUBMISSION.
5. DETAILS NOT DEPICTED SHALL BE CONSTRUCTED IN A MANNER CONSISTENT WITH THE DETAIL DRAWINGS.
6. IF THERE IS A POTENTIAL HAZARDOUS MATERIAL ENCOUNTERED DURING THE COURSE OF WORK THAT IS NOT IDENTIFIED IN THE CONTRACT DOCUMENTS, THE CONTRACTOR WILL STOP WORK IMMEDIATELY AND CONTACT THE OWNER WHO IS TO MAKE A DETERMINATION IF THE MATERIAL
IS HAZARDOUS.
7. ALL DUMPSTERS MUST BE AT LEAST 15 FEET FROM THE BUILDING UNLESS EMPTIED AT THE END OF EACH WORK DAY.
8. MATERIALS MAY NOT BE STORED CLOSER THAN 15 FEET FROM BUILDINGS AND MAY NOT BE PLACED IN FRONT OF EXITS OR ANY FIRE PROTECTION EQUIPMENT. REFUELING OF GASOLINE POWERED EQUIPMENT WILL NOT BE PERMITTED ON THE ROOF. GASOLINE MUST BE STORED IN UL LISTED
AND APPROVED CONTAINERS.
9. REMOVE, STORE, PROTECT AND REINSTALL EXISTING EQUIPMENT, ASSOCIATED MECHANICAL/ELECTRICAL PENETRATIONS, AND CONDUIT SCHEDULED TO REMAIN. TEMPORARY SUPPORTS SHALL BE PROVIDED AS REQUIRED, BY THE CONTRACTOR, TO FACILITATE WORK. ALL UTILITIES
SHALL REMAIN OPERATIONAL DURING THE DURATION OF WORK.
9. THE GENERAL AND SUBCONTRACTORS INSTALLING WORK DEFINED IN THE CONTRACT DOCUMENTS SHALL CONFORM TO THE CURRENT EDITION OF THE DISTRICT OF COLUMBIA BUILDING CODE, PROJECT SPECIFICATIONS, AND THIS DESIGN PACKAGE.
10. FOR THE SAKE OF CLARITY, EACH INDIVIDUAL DETAIL ON THE PLANS HAS NOT BEEN INDICATED. INSTALLATION DETAILS HAVE BEEN INDICATED FOR
TYPICAL COMPONENTS AT RANDOM LOCATIONS.
11. CONCRETE REPAIR AREAS INDICATED ON SHEET A-103 ARE FOR REPRESENTATION ONLY AND SHOULD NOT BE USED AS A MEANS FOR
QUANTIFYING.
12. DISCREPANCIES NOTED BY THE CONTRACTOR IN THE DRAWINGS OR SPECIFICATIONS MUST BE BROUGHT TO THE OWNER'S ATTENTION PRIOR TO
BID SUBMISSION.
13. ALL ITEMS OF CONSTRUCTION SHALL BE IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REGULATIONS APPLICABLE TO THE PROJECT.
14. THE CONTRACTOR SHALL REPORT DETERIORATED OR UNSUITABLE STRUCTURAL CONCRETE OR SUBSTRATES TO THE OWNER AND ENGINEER IN
WRITING PRIOR TO PERFORMING OR CONTINUING WITH THE WORK.
15. THE CONTRACTOR IS RESPONSIBLE FOR SEGREGATING WORK AREAS FROM THE GENERAL PUBLIC USING SIGNS, CONES, CAUTION TAPE, ETC. THE
CONTRACTOR SHALL CONTAIN ALL DUST AND DEBRIS DURING ALL PHASES OF THE WORK.
16. UPON COMPLETION OF THE WORK AND PRIOR TO FINAL PAYMENT, THE CONTRACTOR SHALL SUBMIT AN ALL-INCLUSIVE LABOR AND MATERIALS GUARANTEE OF THE WORK TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP. THIS GUARANTEE SHALL BE FOR A PERIOD OF TWO (2) YEARS AND SHALL BE SIGNED BY A PRINCIPAL OF THE CONTRACTOR'S FIRM AND SEALED IF A CORPORATION.
17. THE CONTRACTOR'S BASE BID FOR THIS PROJECT MUST INCLUDE ALL LABOR, MOBILIZATION, PERMITTING, MATERIALS, TEMPORARY PROTECTION, ETC. NO ADDITIONAL COSTS WILL BE SUBMITTED TO THE OWNER OR ENGINEER IN ORDER TO COMPLETE THE INTENT OF THE WORK AS INDICATED
ON THE DESIGN DRAWINGS.
18. THE CONTRACTOR PERSONNEL PRESENT AT THE SITE DURING ALL PHASES OF THE WORK MUST BE MAINTAINED BY THE CONTRACTOR FOR THE DURATION OF THE WORK. THE CONTRACTOR'S WORKERS SHALL NOT BE CHANGED OR ROTATED DURING THE DURATION OF THIS PROJECT UNLESS SPECIFICALLY TRAINED FOR THIS PARTICULAR RENOVATION PROJECT AND APPLICATION - NO EXCEPTIONS.
19. THE CONTRACTOR IS TO COORDINATE ON-SITE USE OF WATER & ELECTRICITY WITH THE OWNER.
20. WATERPROOFING AND CONCRETE REPAIR MATERIAL MANUFACTURER'S TECHNICAL REPESENTATIVE AND SUBCONTRACTORS MUST BE PRESENT AT THE PROJECT PRECONSTRUCTION MEETING AND MUST INCLUDE PERIODIC SITE VISITS WITH FORMAL REPORTING AS SPECIFIED.
21. CONTRACTOR SHALL PERFORM REPAIR WORK IN ACCORDANCE WITH THE OWNER'S PHASING REQUIREMENTS, WHICH WILL INVOLVE OVERNIGHT WORK. REFER TO THE BID REQUIREMENTS FOR ADDITIONAL INFORMATION REGARDING SCHEDULE AND OVERNIGHT WORK REQUIREMENTS.
22. THE CONTRACTOR SHALL PROVIDE SHORING OF STRUCTURES AS REQUIRED.
23. JOB SITE SAFETY IS THE CONTRACTOR'S RESPONSIBILITY. GALE REPRESENTATIVES, INCLUDING SUBCONSULTANTS RETAINED BY GALE, MAY VISIT THE JOB SITE FROM TIME TO TIME. THESE VISITS ARE FOR CLARIFICATION OF SPECIFIC DESIGN RELATED ISSUES ONLY AND ARE NOT FOR THE PURPOSE OF JOB SITE SAFETY. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO COMPLY WITH ALL SITE SAFETY APPLICABLE REQUIREMENTS
STANDARD ABBREVIATIONS
BUILDING
BRICK MASONRY UNIT
CONCRETE MASONRY UNIT
CONCRETE
CONTINUOUS
COVER
ELEVATION
EQUAL
EXPANSION JOINT
EXISTING
EXTERIOR
FASTENER
FOOT
INCH
INTERIOR
INSULATION
LADDER
MAXIMUM
MECHANICAL
MEMBRANE
MINIMUM
METAL
NOT APPLICABLE
NOT IN CONTRACT
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OPPOSITE HAND
SIMILAR
SLEEVE
SHEET METAL
STAINLESS STEEL
STEEL
STRUCTURAL
TO REMAIN
TYPICAL
VERIFY IN FIELD
BLDG
BMU
CMU
CONC
CONT
CV
EL
EQ
EJ
EX
EXT
FRT
FT
IN
INT
INSUL
LAD
MAX
MECH
MEMB
MIN
MTL
NA
NIC
NO
NOM
NTS
O.C.
OH
SIM
SLV
SM
SS
STL
STRUCT
TR
TYP
VIF
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
G 0X
.D W
G
• 4
/22 /20
3:
:56
P M
M
LF
656429 G0x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
V
ACCESS HATCHH
TL TRAFFIC LIGHT
VENT
LIGHT POST
BUILDING ENTRANCE
L
STREET SIGN
D SHEET METAL DUCT WORK
NOTE: NOT ALL SYMBOLS NECESSARILY USED
STANDARD LEGEND
P PARKING METER
S SANITARY SEWER COVER
T TRASH CAN
B PLANTER BOX
M MAN HOLE COVER
FIRE DEPARTMENT HYDRANT
STEEL FENCE
METRO SURVEY MONUMENT
W WATER VALVE
FOUNDATION WALL EXTENTS
LIGHTNING PROTECTION
PENETRATION
NOTE: NOT ALL ABBREVIATIONS
NECESSARILY USED
G-003
GENERAL
NOTES
(CONTINUED)
AS NOTED
1. ALL CONCRETE REPAIRS SHALL BE PERFORMED IN ACCORDANCE WITH THESE TECHNICAL NOTES, THE PROJECT SPECIFICATIONS, AND REPAIR DETAILS AS WELL AS MANUFACTURER'S SPECIFIC REQUIREMENTS
FOR THE SPECIFIED PRODUCTS.
2. DO NOT FEATHER EDGE ANY REPAIRS. THE MIN. REPAIR MORTAR APPLICATION THICKNESS IS PREFERRED
TO BE 1”, HOWEVER, NEVER LESS THAN ½” THICK AT PERIMETERS.
3. ALL LOOSE, DETERIORATED, SOFT, CARBONATED, DELAMINATING, SEGREGATED, CRACKED AND OTHER DEFICIENT CONCRETE MUST BE FULLY REMOVED DOWN TO SOLID CONCRETE SUBSTRATE. NOTIFY ENGINEER IF CRACKS ARE OBSERVED BEHIND THE SPALL AFTER THE DETERIORATED CONCRETE IS
REMOVED.
4. PERIMETERS OF ALL SPALL REPAIRS MUST BE SAW-CUT TO A “NORMAL” STRAIGHT EDGE IN A POLYGON SHAPE. IN NO CASE REINFORCING STEEL OR OTHER EMBEDDED ITEMS BE CUT OR DAMAGED. THE
CONTRACTOR MUST PROVIDE GROUND PENETRATING RADAR OR OTHER MEANS OF ELECTRONIC
SCANNING TO LOCATE AND MARK EMBEDDED STEEL TO AVOID CUTTING. DAMAGE TO ANY STEEL
REINFORCING OR OTHER EMBEDDED ITEMS DUE TO CUTTING/ REMOVAL OF THE DETERIORATED
CONCRETE SHALL BE REPAIRED AT NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR MUST
PROVIDE ELECTRIC CURRENT SCANNING TO LOCATE AND MARK EMBEDDED CONDUIT.
5. ALL SPALL REPAIR AREA SUBSTRATES MUST BE THOROUGHLY EXAMINED AFTER COMPLETING THE FINAL SURFACE PREPARATION, TO VERIFY THAT NO ADDITIONAL SUBSTRATE CRACKING OR OTHER STRUCTURAL CONDITIONS EXIST. NOTIFY GALE IF ANY CRACKS OR OTHER DETERIORATED CONDITIONS ARE IDENTIFIED.
6. SPALL REPAIR SURFACE PROFILE MUST ACHIEVE AN ICRI-CSP 8 OR 9. WHERE ACCESS IS LIMITED OR DIFFICULT DUE TO PIPING OR OTHER OBSTRUCTIONS, THEN AN ICRI-CSP 7 SURFACE PROFILE MAY BE
CONSIDERED AS APPROVED BY THE ENGINEER.
7. RUSTED REINFORCING STEEL BARS MUST BE FULLY CLEANED TO BRIGHT, SHINY STEEL TO CONFORM TO SSPC SP11 REQUIREMENTS. WHERE REINFORCING STEEL IS SHOWING SECTION LOSS OF 18" OR 25% OR MORE SECTION LOSS, SUPPLEMENTAL REINFORCING STEEL MUST BE PLACED TO ACHIEVE A MINIMUM OF 20 BAR DIAMETER LENGTH LAPS, AND TIED DIRECTLY ADJACENT TO SOLID BAR SECTIONS THAT DO NOT HAVE SECTION LOSS. ADDITIONAL CONCRETE REMOVAL AND DRILLING WILL BE REQUIRED TO PLACE THE
NEW REINFORCING STEEL.
8. REMOVE ADDITIONAL CONCRETE BEHIND AND AROUND ALL REINFORCING STEEL BARS WHICH ARE CORRODED SO THAT PROPER AND THOROUGH CLEANING MAY BE ACHIEVED AROUND THE ENTIRE BAR. A MINIMUM OF 1” CLEAR, UNOBSTRUCTED SPACE AROUND EACH REINFORCING STEEL BAR MUST BE ACHIEVED ALONG THE FULL LENGTH OF THE BAR IN THE AREA OF THE SPALL REPAIR. CLEAN BARS TO ACHIEVE SSPC-SP11 COMPLIANCE. BARS MUST BE FULLY UNCOVERED TO COMPLY WITH THAT NOTED
HEREIN, IF ANY PORTION OF THE REBAR IS EXPOSED AND IT IS RUSTED.
9. IN ALL CASES, THE EXISTING AND NEW REINFORCING STEEL MUST HAVE A MINIMUM CONCRETE/REPAIR MORTAR COVER OF 1 ½”. NOTIFY THE ENGINEER IF MODIFICATION OF STEEL PLACEMENT OR CONCRETE
THICKNESS IS REQUIRED TO ACHIEVE THIS REQUIREMENT.
10. WITH LARGE OR DEEPER SPALL REPAIR AREAS, WITH DEPTHS EXCEEDING 3 INCHES, IF NO EXISTING REBAR IS PRESENT, OR REBAR GRID IS SEPARATED BY MORE THAN 6 INCHES, THEN THE SUBSTRATE OF THE REPAIR MUST BE PINNED WITH STAINLESS STEEL, 8 MM HELICAL TIES; OR STAINLESS STEEL FULLY THREADED CAP SCREWS WITH HEX HEADS PROJECTING OUTWARD BY 2 INCHES INTO THE MEDIUM OF THE REPAIR. DRILL HOLES FOR THREADED BOLTS (CAP SCREWS) TO 1/8” TO ¼” LARGER THAN THE BOLT DIAMETER. BOLT DIAMETERS SHALL BE 3/16” TO ¼”, AND SHALL BE EMBEDDED 2 INCHES INTO SOLID CONCRETE. USE SPECIFIED STRUCTURAL ADHESIVE TO PLACE THREADED ROD PINS. HELICAL ANCHOR PINS, IF USED, MUST BE DRIVEN USING THE MANUFACTURER REQUIRED DRIVING TOOL AND BIT. PLACE PINS A MAXIMUM OF 8 INCHES ON CENTER, AND TIE 2” X 2” X 14 GAGE HOT-DIP GALVANIZED OR STAINLESS STEEL MESH FROM PIN-TO-PIN. PLACE THE MESH 2” FROM THE BELLY OF THE PREPARED SPALL AREA, WHILE ALWAYS MAINTAINING A MINIMUM 1 ½” OF CONCRETE/REPAIR MORTAR COVER AT THE OUTSIDE
SURFACE OF THE REPAIR.
11. WHEN DRILLING INTO SOLID CONCRETE TO PLACE NEW SUPPLEMENTAL STEEL REINFORCING BARS, DRILL
THE HOLES ¼” LARGER THAN THE BAR DIAMETER. FULLY VACUUM, BLOW OUT (WITH OIL FREE
COMPRESSED AIR) AND BRISTLE BRUSH OUT THE HOLES TO REMOVE ALL DUST, DEBRIS, LAITANCE, ETC.
THE DEPTH OF THE HOLES MUST BE DETERMINED BY THE ENGINEER BASED UPON BAR SIZE, LOCATION, AND NEED FOR DEVELOPMENT. THIS WILL BE DETERMINED ON A CASE BY CASE BASIS. IN NO CASE SHALL THE DRILLED HOLES BE LESS THAN THAT NOTED IN THE PROJECT SPECIFICATIONS UNLESS APPROVED BY THE ENGINEER. IN NO CASE SHALL SUPPLEMENTAL BARS BE LESS THAN #4 BARS, UNLESS OTHERWISE APPROVED BY THE ENGINEER. NEW REINFORCING STEEL BARS MAY BE #5 OR LARGER, DEPENDING UPON THE EXTENT OF REINFORCEMENT CORROSION AND NEED FOR SUPPLEMENTAL STEEL.
BARS EMBEDDED INTO CLEANED DRILLED HOLES MUST BE FULLY ADHERED IN PLACE USING SIKADUR 31
HI-MOD AS MANUFACTURED BY SIKA CORPORATION, OR ENGINEER APPROVED EQUAL.
12. JUST PRIOR TO PLACING THE REPAIR MORTAR AND FORMWORK, THE ENTIRE SUBSTRATE OF THE SPALL REPAIR MUST BE THOROUGHLY CLEANED OF ALL BOND INHIBITING MATERIALS, BROUGHT TO SATURATED SURFACE DRY (SSD) CONDITION WITH POTABLE WATER OR RECEIVE THE BONDING AGENT OR BRISTLE BRUSH APPLIED BONDING SLURRY (ALL AS REQUIRED BY THE MATERIAL MANUFACTURER) AND BE CLEANED REBAR COATED WITH SPECIFIED COATING. APPLY TWO (2) COATS OF THE SPECIFIED REBAR COATING ON CLEANED EXISTING STEEL WITHOUT SPILLING THE MATERIAL ON ANY OTHER SURFACES OR COMPONENTS. DO NOT ALLOW THE COATING TO DRY BETWEEN COATS, NOR DRY PRIOR TO APPLYING THE REPAIR MORTAR. ALL MATERIALS MUST BE APPLIED IN A “WET-ON-WET” CONDITION FOR GREATER
BOND.
13. FOLLOW ALL CURRENT MANUFACTURER DATA SHEETS AND CURRENT ACI AND ICRI CONCRETE REPAIR REQUIREMENTS AND CODE REGULATIONS FOR PROPER PLACEMENT, VIBRATION, CURING AND STRIPPING
OF FORMS.
14. THE CONTRACTOR SHALL HIRE AND COORDINATE THE SERVICES OF THE MANUFACTURER'S TECHNICAL FIELD REPRESENTATIVE TO VISIT THE SITE A MINIMUM OF ONE (1) TIME PER WEEK DURING THE CONSTRUCTION PERIOD. MANUFACTURER'S SITE VISITS ARE REQUIRED FOR THE CRACK AND CONCRETE REPAIR MORTAR APPLICATION. THE MANUFACTURER'S REPRESENTATIVE SHALL REVIEW MATERIAL STORAGE, MIXING, INSTALLATION, CURING, ETC. AND SUBMIT A WRITTEN FIELD REPORT INDICATING
OBSERVATIONS AND RECOMMENDATIONS FOR EACH SITE VISIT.
15. REFER TO THE QUALITY ASSURANCE SECTION OF THE TECHNICAL NOTES ON THIS SHEET.
16. REPAIRS ARE PART OF A PHASED REPAIR PROJECT WHICH HAVE BEEN COORDINATED WITH THE OWNER.
REFER TO PROJECT SPECIFICATIONS.
17. GALVANIC ANODES SHALL BE PLACED IN ALL CONCRETE SPALL REPAIR AREAS. USE MINIMUM ONE (1)
ANODE IN ALL SPALL REPAIRS WHERE SPECIFIED SPACING CANNOT BE ACHIEVED (SPALLS
W/DIMENSIONS LESS THAT 18”) ANODES SHALL BE PLACED WITHIN 4” OF THE SPALL REPAIR AREA PERIMETER. MAINTAIN A MINIMUM SPACE OF 1-1/2” AROUND THE FULL PERIMETER OF THE ANODES
TO ALLOW CONCRETE REPAIR MORTAR PLACEMENT. TIE THE ANODES TO CLEANED AND
SUPPLEMENTAL REINFORCING STEEL. THE CONTRACTOR MUST PERFORM CONTINUITY
MEASUREMENTS VIA USE OF CALIBRATED ELECTRONIC DIGITAL OHM METER FOR EACH ANODE
CONNECTION AND LEAD-WIRE. CONTINUITY MEASUREMENTS MUST BE RECORDED BY THE
CONTRACTOR AND SUBMITTED TO THE ENGINEER AND OWNER INCLUSIVE CATALOGUED REPAIR
LOCATION. WHERE AVAILABLE, TIE ANODES TO CROSS BARS AND INTERSECTING BARS.
18. ALL CONCRETE PATCH REPAIRS MUST BE APPLIED VIA FORM-AND -POUR METHODS. HAND PATCHING IS
NOT ALLOWED ON THIS PROJECT.
1. EXISTING STRUCTURES, UTILITY LINES AND EMBEDDED UTILITIES MUST BE COORDINATED
WITH AND IDENTIFIED BY THE OWNER AND CONTRACTOR, AND MARKED ON-SITE PRIOR TO
INITIATING CONSTRUCTION. IN THE EVENT THAT ANY UNMARKED OR UNKNOWN
STRUCTURE/UTILITY ARE UNCOVERED BY THE CONTRACTOR, WORK MUST HALT AND THE
CONTRACTOR SHALL REPORT ITS FINDINGS TO THE OWNER'S SITE REPRESENTATIVE FOR
INSTRUCTIONS BEFORE PROCEEDING FURTHER. THE EXISTING STRUCTURES AND
UTILITIES WHICH ARE ADJACENT TO THE SITE AND THOSE TO REMAIN WITHIN THE LIMITS
OF THE WORK SHALL BE PROTECTED AGAINST DAMAGE. THE CONTRACTOR SHALL BE
FULLY RESPONSIBLE TO THE OWNER IN THE EVENT OF REMOVAL OF OR DAMAGE TO ANY
EXISTING OBJECTS BY CONTRACTORS PERSONNEL, WHICH ARE INTENDED BY THE OWNER
TO REMAIN IN PLACE.
1. CONTRACTOR MUST COORDINATE AND PAY FOR ALL MATERIAL MANUFACTURER'S SITE
VISITS TO REVIEW CONSTRUCTION. AT A MINIMUM, THE MANUFACTURER'S TECHNICAL
REPRESENTATIVE SHALL BE ON SITE FOR THE FOLLOWING REVIEWS:
A. PRE-CONSTRUCTION MEETING.
B. CONCRETE PREPARATION PRIOR TO INSTALLATION OF MATERIALS.
C. REVIEW MATERIAL STORAGE, MIXING, SURFACE PREPARATION, APPLICATION,
CURING AND TEMPORARY PROTECTION FOR EACH MATERIAL TYPE OR COMPONENT.
D. MINIMUM ONE (1) SITE VISIT PER WEEK DURING INSTALLATION. MOCK-UP OF EACH
REPAIR TYPE WITH MANUFACTURER'S REPRESENTATIVE PRESENT.
E. PERIODIC TESTING OF MATERIAL THICKNESS TO CONFIRM CONFORMANCE TO
MANUFACTURER'S WRITTEN TECHNICAL DATA AND THESE CONTRACT DOCUMENTS.
2. FOR EACH SITE VISIT, THE MANUFACTURER'S REPRESENTATIVE MUST PROVIDE A WRITTEN
FIELD REPORT INDICATING AREAS REVIEWED, PROCEDURES USED, RECOMMENDATIONS
MADE, INCORRECT INSTALLATIONS, CORRECTIVE ACTIONS AND PHOTOGRAPHIC
DOCUMENTATION. THE WRITTEN FIELD REPORT MUST INCLUDE DATE, TIME, COMPLETE
LIST OF PERSONNEL ON SITE, AREAS REVIEWED WITH SKETCH PLAN IDENTIFICATION;
PLACED WITH PHOTO DOCUMENTS ON MANUFACTURER'S COMPANY LETTERHEAD.
3. THE CONTRACTOR SHALL OBTAIN AND PROVIDE COPIES OF ALL MATERIAL AND SYSTEM
WARRANTIES TO THE OWNER.
CONCRETE REPAIR NOTES PROTECTION OF EXISTING STRUCTURES QUALITY ASSURANCE
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
G 0X
.D W
G
• 4
/22 /20
3:
:56
P M
M
LF
656429 G0x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
1. THE CONTRACTOR SHALL PROVIDE A SECURE AND WEATHER RESISTANT TEMPORARY
STRUCTURE(S), AS REQUIRED, AT LOCATIONS OF THROUGH SLAB CONCRETE REPAIRS AT
THE G-STREET SIDEWALK VAULT. THE STRUCTURE WILL BE SIZED TO ALLOW FOR
DEMOLITION AND REPAIRS TO STRUCTURAL CONCRETE SLABS WITH SECURE DOORS AND
LOCKS APPROVED BY THE OWNER.
SECURITY OF EXISTING STRUCTURES
NOTE 1:
INSPECTION OR TESTING SHALL BE PROVIDED FOR ALL MATERIAL, COMPONENTS AND WORK LISTING IN THE TABLES
BELOW.
NOTE 2:
DEFINITIONS:
A. CONTINUOUS INSPECTION: INDICATES SPECIAL INSPECTOR SHALL BE PRESENT DURING CONTRACTOR
PERFORMANCE OF THE TASK.
B. PERIODIC INSPECTION: INDICATES SPECIAL INSPECTOR SHALL PROVIDE INSPECTION OR TESTING OF ALL WORK INDICATED, BUT THAT SPECIAL INSPECTOR IS NOT REQUIRED TO BE PRESENT DURING CONTRACTOR PERFORMANCE OF THE TASK. PERIODIC INSPECTION DOES NOT MEAN RANDOM INSPECTION IS ALLOWED.
STATEMENT OF SPECIAL INSPECTIONS
REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION
TYPE CONTINUOUS SPECIAL
INSPECTION
PERIODIC SPECIAL
INSPECTION REFERENCE STANDARD IBC REFERENCE
1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS, AND VERIFY
PLACEMENT — ACI: CH. 20, 25.2, 25.3,
26.6.1-26.6.3 1908.4000
2. REINFORCING BAR WELDING:
A) VERIFY WELDABILITY OF REINFORCING BARS
OTHER THAN ASTM A706;
B) INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM
5/16"; AND
C) INSPECT ALL OTHER WELDS.
X
X X
AWS D1.4
ACI 318: 17.8.2 —
3. INSPECT ANCHORS CAST IN CONCRETE — X ACI 318: 17.8.2 —
4. INSPECT ANCHOR POSTS-INSTALLED IN HARDENED CONCRETE MEMBERS. (B)
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY
OR UPWARDLY INCLINED ORIENTATIONS TO
RESIST SUSTAINED TENSION LOADS.
B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS
NOT DEFINED IN 4.A.
X X ACI 318: 17.8.2.4
ACI 318: 17.8.2 —
5. VERIFY USE OF REQUIRED DESIGN MIX.
— X ACI 318: CH. 19, 26.4.3, 26.4.4 1904.1, 1904.2, 1908.2,
1908.3
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS,
PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE OF THE
CONCRETE. X X
ASTM C172
ASTM C31
ACI 318: 26.5, 26.12
1908.1000
7. INSPECT CONCRETE AND SHOTCRETE PLACEMENT FOR PROPER APPLICATION
TECHNIQUES. X — ACI 318: 26.5 1908.6000, 1908.7000,
1908.8000
8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
— X ACI 318: 26.5.3-26.5.5 1908.9000
9. INSPECT PRESTRESSED CONCRETE FOR:
A. APPLICATION OF PRESTRESSING FORCES; AND
B. GROUTING OF BONDED PRESTRESSING TENDONS.
X X
— ACI 318: 26.10 —
10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS. — X ACI 318: 26.9 —
11. VERIFY IN-SITU CONCRETE STRENGTH, PRIOR TO STRESSING OF TENDONS IN
POST-TENSIONED CONCRETE AND PRIOR TO REMOVAL OF SHORES AND FORMS FROM
BEAMS AND STRUCTURAL SLABS. — X ACI 318: 26.11.2 —
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE
MEMBER BEING FORMED. — X ACI 318: 26.11.1.2(B) —
AutoCAD SHX Text X
G-004
GENERAL
NOTES
(CONTINUED)
NONE
1. ALL DIMENSIONS AND CONDITIONS MUST BE FIELD VERIFIED AND ANY DISCREPANCIES SHALL
BE BROUGHT TO THE ATTENTION OF THE OWNER BEFORE PROCEEDING WITH THE AFFECTED
PORTION OF THE WORK.
2. SHOP DRAWINGS FOR REINFORCING STEEL (INCLUDING ALL ACCESSORIES), POUR
SCHEDULES, AND CONCRETE MIX DESIGN SHALL BE SUBMITTED TO THE ENGINEER AND
STAMPED ACCEPTANCE RECEIVED PRIOR TO FABRICATION. ERECTION SHALL PROCEED
BASED ON ACCEPTED SHOP DRAWINGS ONLY.
3. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY SHORING AND BRACING
FOR THE AFFECTED AREAS OF THE BUILDING DURING THE ENTIRE CONSTRUCTION PROCESS.
4. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE LATEST EDITIONS OF THE
FOLLOWING BUILDING AND TRANSPORTATION CODES AND STANDARDS:
· 2017 DISTRICT OF COLUMBIA BUILDING CODE
· DCMR 12J EXISTING BUILDING CODE SUPPLEMENT OF 2017
· DCMR 24 PUBLIC SPACE AND SAFETY
· ADA STANDARDS FOR ACCESSIBLE DESIGN BY THE U.S. DEPARTMENT OF JUSTICE
· DC CODE CHAPTER 11 AND APPENDIX E
· ICC/ANSI 117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
· DDOT STANDARDS AND SPECIFICATIONS FOR HIGHWAYS AND STRUCTURES WITH
2020 DDOT SPECIFICATIONS REVISION
· DDOT DESIGN AND ENGINEERING MANUAL
6. DESIGN LOADS:
DESIGN CODE(S) - AS INDICATED THIS SECTION
BUILDING RISK CATEGORY - II
EXTERIOR FRAMED CONCRETE SIDEWALKS:
DEAD LOADS......................................................ACTUAL WEIGHT
SNOW LOADS:
GROUND SNOW LOAD, pg...........................25 PSF
LIVE LOADS:
IN ACCORDANCE WITH ASCE 7-16
UNIFORM LOAD...............................250 PSF
1. CONCRETE SLAB-ON-GRADE CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS FOR CLASS E PORTLAND CEMENT CONCRETE AS SPECIFIED BY THE 2020 DDOT STANDARD SPECIFICATIONS FOR
HIGHWAY STRUCTURES, INCLUDING, BUT NOT LIMITED TO THE FOLLOWING:
1.1. MINIMUM 28 DAY COMPRESSIVE STRENGTH, f'c 3500 PSI
1.2. SLUMP RANGE 0-3 IN
1.3. MAXIMUM WATER/CEMENT RATIO 0.49
1.4. COARSE AGGREGATE SIZE 57, OR 57 AND 4,
OR 67 AND
1.5. AIR CONTENT 5-8%
1.6. MINIMUM CEMENT CONTENT 565 LB/C.Y.
1.7. FINE AGGREGATE SIZE AND QUALITY AASHTO M6
1.8. WELDED WIRE FABRIC AASHTO M 55
1.9. DEFORMED REINFORCING STEEL AASHTO M31, Gr.
1.10. EPOXY-COATED REINFORCEMENT STEEL ASTM A775
1.11. POLYETHYLENE SHEETING AASHTO M 171
2. WHERE CONTINUOUS BARS ARE CALLED FOR THEY SHALL BE RUN CONTINUOUSLY AROUND CORNERS AND LAPPED AT NECESSARY SPLICES OR HOOKED AT DISCONTINUOUS ENDS. LAPS SHALL BE 40 BAR DIAMETERS (MINIMUM), UNLESS OTHERWISE SHOWN. USE 2'-0"x 2'-0" CORNER BARS AT EACH CORNER
FOR EACH CONTINUOUS HORIZONTAL BAR.
3. ALL REINFORCING BARS SHALL BE COLD BENT IN ACCORDANCE TO THE PROPER RADII ESTABLISHED BY THE AMERICAN CONCRETE INSTITUTE. UNDER NO CONDITIONS SHALL HEAT BE APPLIED TO THE
BARS TO OBTAIN BENDS.
4. FORMS SHALL BE OILED PRIOR TO THEIR ERECTION. REINFORCING BARS WHICH ARE COATED WITH
FORM OIL OR ANY OTHER BOND BREAKING MATERIAL WILL BE REJECTED AND WILL REQUIRE
REPLACEMENT AT NO ADDITIONAL COST TO THE OWNER.
5. CONCRETE SHALL NOT CONTAIN SLAG OR SILICA FUME. IF USING FLY-ASH, THE MAXIMUM QUANTITY PER WEIGHT OF CEMENT SHALL BE 15%. FLY-ASH SHALL CONFORM TO AASHTO M295, CLASS C OR
CLASS F. SUBMIT FLY-ASH CERTIFICATION FOR APPROVAL WITH MIX DESIGNS.
6. SUBMIT COMPLETE REINFORCING STEEL SHOP DRAWINGS ALONG WITH COMPLETE CONCRETE MIX DESIGN (INCLUDING ALL ADDITIVES AND THEIR CONTENT) TO THE ENGINEER FOR REVIEW AND
APPROVAL PRIOR TO FABRICATING STEEL.
7. ADDITION OF WATER TO CONCRETE MIXES AT THE SITE IS NOT ALLOWED. SUCH CONCRETE SHALL BE IMMEDIATELY REJECTED. MID-RANGE, OR HIGH RANGE, OR SUPERPLASTICIZERS ARE ALLOWED IN THE MIX TO ASSIST IN WORKABILITY AND PUMPING OPERATIONS, AND MIX-DESIGN MAKE-UP WATER MAY BE
POST SUPPLEMENTED AT THE SITE. TESTING FIRM MUST MEASURE AND REPORT.
8. ALL CONCRETE SHALL BE READY-MIXED AT PLANT COMPLYING WITH AASHTO M157. SITE/HAND MIXING
IS NOT ALLOWED AND SHALL BE REJECTED.
9. ALL CONCRETE SHALL BE REINFORCED AS SHOWN ON THE DRAWINGS. PROVIDE SUFFICIENT CHAIR OR SUPPORT BARS AS NECESSARY TO PROPERLY POSITION REINFORCING STEEL. PULL UP OF BARS OR MESH, OR UNSUPPORTED BARS OR MESH WILL NOT BE ALLOWED. "WET STICKING" OF BARS WILL NOT
BE ALLOWED.
10. ALL CONCRETE SHALL BE POURED TO THE SPECIFIED THICKNESS AND REINFORCED AS SHOWN ON THE DRAWINGS. WELDED WIRE MESH REINFORCEMENT SHALL CONFORM TO A.S.T.M. A185, AND SHALL LAP 6" MINIMUM OR ONE SPACE, WHICHEVER IS LARGER, AND SHALL BE WIRED TOGETHER. IT IS REQUIRED THAT CHAIR BARS BE USED TO MAINTAIN PROPER LOCATION OF WELDED WIRE MESH.
11. FIELD TESTING OF CONCRETE USED FOR SLABS-ON-GRADE SHALL CONFORM TO THE DDOT
SPECIFICATIONS SECTION 501.15, INCLUDING BUT NOT LIMITED TO:
· AIR CONTENT OF PLASTIC CONCRETE AASHTO T196 OR T152
· SLUMP - AASHTO T119
· COMPRESSIVE STRENGTH AASHTO T23
· FLEXURAL STRENGTH AASHTO T117
· CONTRACTOR SHALL PROVIDE CONCRETE CYLINDER CURING FACILITIES AT THE PROJECT SITE.
SPECIMENS SHALL BE STORED UP TO 48-HOURS IN A CONCRETE CURING BOX. ONE (1) SET OF TEST SPECIMENS SHALL BE MADE FOR EVERY FIFTY (50) CUBIC YARDS OF CONCRETE PLACED, AND SHALL BE OBTAINED FROM EACH CONCRETE DELIVERY TRUCK.
· CONTRACTOR SHALL BE RESPONSIBLE FOR TRANSPORTING THE CONCRETE SPECIMENS TO
THE DEPARTMENT OF TRANSPORTATION MATERIALS TESTING FACILITY.
· CONTRACTOR SHALL BE RESPONSIBLE FOR FURNISHING ALL TESTING REPORTS TO THE
ENGINEER FOR REVIEW.
· ACCEPTANCE BY THE ENGINEER SHALL BE BASED UPON THE DEPARTMENT OF
TRANSPORTATION MATERIALS TESTING FACILITY TEST RESULTS/REPORTS.
12. CHAIR BARS FOR SECURE PLACEMENT AND POSITIONING OF REINFORCING STEEL IS TO BE PROVIDED.
CHAIR BAR OR SIMILAR APPROVED MANUFACTURED DEVICES INTENDED FOR USE MUST BE SUBMITTED TO GALE AND APPROVED IN WRITING PRIOR TO ORDERING MATERIALS. REINFORCING SUPPORTS SHALL BE OF PROPER HEIGHT, LENGTH, SPACING, SIZE AND MATERIAL TYPE; AND SUBMITTAL SHALL INCLUDE THIS DATA WITH CURRENT MANUFACTURER DATA SHEETS. IN NO CASE SHALL BRICK, WOOD
OR OTHER NON-CONFORMING REINFORCING STEEL SUPPORTS BE USED.
13. ALL OTHER REQUIREMENTS NOT LISTED IN THE CONCRETE NOTES, OR PROJECT SPECIFICATIONS AND
DRAWINGS, SHALL CONFORM TO THE DDOT SPECIFICATIONS AND DRAWINGS.
1. ALL REINFORCED CONCRETE MASONRY SHALL CONFORM TO THE LATEST EDITIONS OF
THE NCMA “SPECIFICATION FOR THE DESIGN AND CONSTRUCTION OF LOAD-BEARING
CONCRETE MASONRY," AND ACI 530 "BUILDING CODE REQUIREMENTS FOR MASONRY
CONSTRUCTION.
2. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90, GRADE N, TYPE I NORMAL
WEIGHT BLOCK AND HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI ON THE NET
AREA. BRICK MASONRY SHALL CONFORM TO ASTM C62, GRADE SW AND HAVE A MINUMUM
COMPRESSIVE STRENGTH OF 2500 PSI ON THE NET AREA.
3. MORTAR SHALL CONFORM TO ASTM C270, TYPE S MORTAR FOR THE REINFORCED
CONCRETE MASONRY AND TYPE N FOR THE BRICK MASONRY.
4. GROUT TO FILL CELLS AND BOND BEAMS SHALL CONFORM TO ASTM C476, FINE TYPE, AND
SHALL HAVE A MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 PSI:
a. ALL GROUTING PROCEDURES SHALL CONFORM TO NCMA "TEK SERIES #23A" 9-02B
AND 9-04A.
b. GROUT SLUMP SHALL BE BETWEEN 8 AND 11 INCHES. SUBMIT MIX DESIGN TO
ENGINEER FOR APPROVAL.
5. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615, GRADE 60, DEFORMED.
6. PROVIDE HORIZONTAL AND VERTICAL REINFORCING AS NOTED ON THE DRAWINGS AND
FILL ALL CELLS WITH REINFORCEMENT WITH GROUT. REFER TO “MINIMUM WALL
REINFORCING SCHEDULE,” OR SECTIONS, FOR REQUIRED WALL REINFORCEMENT.
HORIZONTAL REINFORCEMENT SHALL BE CONTINUOUS THROUGH CORNERS,
INTERSECTIONS AND PILASTERS, AND SHALL CONSIST OF TRUSS OR LADDER NO. 9 WIRE
SPACED NOT MORE THAN 4'-0" ON CENTER.
7. GROUTING SHALL BE LIMITED TO A MAXIMUM WALL HEIGHT OF 64 INCHES PER LIFT, AND
MUST BE VERIFIED FOR FULL HEIGHT SOLID PLACEMENT VIA CODE REQUIRED CLEAN OUTS.
8. ALL CMU DESIGN AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF
CHAPTERS 1 THROUGH 8 OF ASCE/ACI 530. PLACE CMU IN RUNNING BOND.
9. SET REINFORCING BARS AS INDICATED. PROVIDE VERTICAL AND HORIZONTAL LAP
SPLICES, 40 BAR DIAMETERS MINIMUM OR OTHERWISE INDICATED. TIE BARS AND CENTER
BARS IN CELL. INSPECT ALL CELLS FOR ALIGNMENT AND DEBRIS IN CELL PRIOR TO
GROUTING.
10. CONTRACTOR TO NOTE THAT FLASHING, WEEPS, END DAMS, SEALANTS AND DRIP-EDGES
ARE REQUIRED AT LOCATIONS SHOWN ON THE DRAWINGS AND SPECIFICATIONS FOR
REQUIRED WORK AND MATERIALS.
STRUCTURAL NOTES CONCRETE SLABS-ON-GRADE
CONCRETE MASONRY NOTES
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
G 0X
.D W
G
• 4
/22 /20
3:
:56
P M
M
LF
656429 G0x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
A-100
WORK AREA
PLAN
NOT TO SCALE
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
A 1X
.D W
G
• 4
/22 /20
3:
:01
P M
M
LF
656429 A1x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
SCALE: N.T.S.
WORK AREA PLANA
A-100
AREA OF WORK
US GOVERNMENT PUBLISHING OFFICE
US GOVERNMENT PUBLISHING OFFICE
G STREET NW
NORTH
ALLEYWAY
NO
RT
H
CA
PI
TO
L S
TR
EE
T
NW
A-101
A-102
222324272829303132333536 34 26 25
D D
363738
W W S
A-101
SIDEWALK PLAN
EXISTING
CONDITIONS
3/16" = 1'
0 4' 8' 12'
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
A 1X
.D W
G
• 4
/22 /20
3:
:02
P M
M
LF
656429 A1x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
SCALE: 3/16" = 1'-0"
SIDEWALK PLAN - EXISTING CONDITIONS1
A-101
D
A-501
A-501
12'± 12'± 12'± 12'± 12'±
MA
TC
H
LIN
E A-
A
MA
TC
H
LIN
E B-
B
A-501
A-502
A-502
A-504
21'-6"± 12'± 12'± 12'±
METAL RAMP
F
CONCRETE APRON
TRAFFIC BOLLARDS
TO REMOVED AND
REINSTALLED AS
REQUIRED
CONCRETE STAIRS
AND WALL
STEEL GUARD RAIL
GENERAL NOTES
1. PROVIDE TEMPORARY, SECURE, PROTECTIVE COVERING OR STRUCTURE AS REQUIRED
AT FULL DEPTH STRUCTURAL SLAB REPAIRS TO MAINTAIN SECURE FACILITY. REFER TO
PROJECT SPECIFICATIONS.
2. EXISTING SIDEWALK CONCRETE WEAR COURSE CONTROL JOINTS ARE SPACED AT
APPROX. 36" O.C. EACH WAY, NOT SHOWN FOR CLARITY.
3. REMOVE AND DISPOSE OF ALL CONCRETE SLABS ON GRADE (APRON), CONCRETE
GUTTER, BRICK GUTTER, CONCRETE SLABS ON GRADE (SIDEWALK), STAIRS, RAMPS,
CONCRETE WEARCOURSE, WATERPROOFING, GUARD RAILS, AND HANDRAILS, UNLESS
SPECIFICALLY INDICATED TO REMAIN.
4. REFER TO A-104, A105, A106 FOR NEW SIDEWALK CONDITIONS. SLOPE TO MATCH EXISTING.
REFER TO CIVIL DRAWINGS.
CONCRETE LANDING DOORS TO REMAIN
ROLL UP GATE
TO REMAIN
ENTRANCE
A-505
KEYPLAN
G STREET NW
NORTH CAPITOL STREET NW
N
US GOVERNMENT PUBLISHING OFFICE
T
CONCRETE SLAB-ON-GRADE SIDEWALK
MA
TC
H
LIN
E A-
A
DD
AREAWAY TO REMAIN
STEEL DIAMOND
PLATE TO REMAIN.
SCRAPE, PRIME AND PAINT
GPO ADDITION
CONCRETE FOUNDATION
WALL (BELOW) TO REMAIN
62'±
ENTRANCE
A-505
A-505
GRANITE ENTRANCE
THRESHOLD TO REMAIN
A-505
BROWNSTONE
CHEEK WALL
CONCRETE SLAB-ON-GRADE SIDEWALK
CONCRETE SLAB-ON-GRADE APRON
GRASS AREA
BOLLARDS TO
REMAIN TYP.
ROLL UP DOORS TO REMAIN (TYP.)
111'±
GPO MAINTENANCE GARAGE
A-505
L
D D
2"X2" STEEL ANGLE TO REMAIN
A-501
13'± 12'±
FRAMED VAULTED SIDEWALK
BRICK GUTTER
TRAFFIC BOLLARDS
TO REMAIN
GPO MAIN BUILDING
BRICK INFILL WALL TO REMAIN
A-505
A-505
A-505
12'±
D
KEYNOTES
PROVIDE SHORING AT SHEET METAL DUCTWORK AS-REQUIRED TO FACILITATE WORK.
REMOVE EXISTING BROWNSTONE CHEEK WALLS. STORE FOR RECONSTRUCTION.
REMOVE AND REPLACE EXISTING DUCTWORK.
PROTECT AND BRACE STORMWATER MANAGEMENT CURB INLET AS REQUIRED DURING
DEMOLITION AND CONSTRUCTION REFER TO CIVIL DRAWINGS
GRANITE CURB TO REMAIN AND BRICK/CONCRETE GUTTER TO REMAIN.
REMOVE, STORE, AND REINSTALL EXISTING PAVERS.
STREET LIGHT TO REMAIN DURING CONSTRUCTION.
STREET SIGN TO BE REMOVED AS REQUIRED DURING CONSTRUCTION. CONTRACTOR TO
PROVIDE TEMPORARY SIGNAGE AS REQUIRED BY DC DOT.
PARKING METER TO BE REMOVED, STORED, AND REINSTALLED.
FIRE HYDRANT TO REMAIN, HYDRANT TO BE FULLY OPERATION DURING CONSTRUCTION.
TRAFFIC LIGHT TO REMAIN AND BE OPERATIONAL THROUGHOUT CONSTRUCTION.
REMOVE AND REPLACE MANHOLE/SEWER COVER, FRAME AND SEALS AS REQUIRED.
WATER VALVE TO REMAIN. REMOVE AND REPLACE COVER AND FRAMING AS REQUIRED.
REMOVE, STORE, AND REINSTALL TRASHCAN.
SIDEWALK CURB AND GUTTER
TO REMAIN N.I.C.
WINDOW TO REMAIN (TYP.)
STEEL FENCE TO REMAIN
REMOVE ALL ITEMS UNLESS DESIGNATED TO REMAIN
C
A
E
D
B
10'±
10'±
1'-6"±
2'±
4'±
DOOR TO REMAIN DOOR TO REMAIN
CONCRETE WEAR COURSE
8 10
2 2
5 BRICK GUTTER
A-501
0 4' 8' 12'
LIGHTENING PROTECTION
TO REMAIN (TYP. ALL)
8 14
SOFTSCAPE TO REMAIN,
RESTORE AS REQUIRED
CONCRETE GUTTER TO REMAIN
13 12
12'±
NORTH
3 3
891011121314151618192021 17
L
34567 2 01
A-102
SIDEWALK PLAN
EXISTING
CONDITIONS
3/16" = 1'
0 4' 8' 12'
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
A 1X
.D W
G
• 4
/22 /20
3:
:03
P M
M
LF
656429 A1x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
CONCRETE RAMP/LANDING
P
12'± 12'± 12'± 12'±
MA
TC
H
LIN
E B-
B
D
TL
TL
M
29'±
P
12'± 12'± 12'± 12'±
CONCRETE ADA
CURB RAMP
4'±
MA
TC
H
LIN
E C-
C
CONCRETE ADA
CURB RAMP
MA
TC
H
LIN
E C-
C
4'±
12'±
12'± 12'±
SCALE: 3/16" = 1'-0"
SIDEWALK PLAN - EXISTING CONDITIONS1
A-102
12'± 12'±
ENTRANCE
CONCRETE ENTRANCE THRESHOLD TO REMAIN DOORS TO REMAIN
M
A-501
SIDEWALK N.I.C.
BRICK GUTTER
CONCRETE AREAWAY CURB,
STRUCTURAL FRAMING, AND
STEEL GRATING TO REMAIN
A-501
BUILDING FACADE TO REMAIN (TYP.)
WINDOWS TO REMAIN (TYP.)
A-501
12'± 12'± 12'±12'±
GENERAL NOTES
1. PROVIDE TEMPORARY, SECURE, PROTECTIVE COVERING OR STRUCTURE AS REQUIRED
AT FULL DEPTH STRUCTURAL SLAB REPAIRS TO MAINTAIN SECURE FACILITY. REFER TO
PROJECT SPECIFICATIONS.
2. EXISTING SIDEWALK CONCRETE WEAR COURSE CONTROL JOINTS ARE SPACED AT
APPROX. 36" O.C. EACH WAY, NOT SHOWN FOR CLARITY.
3. REMOVE AND DISPOSE OF ALL CONCRETE SLABS ON GRADE (APRON), CONCRETE
GUTTER, BRICK GUTTER, CONCRETE SLABS ON GRADE (SIDEWALK), STAIRS, RAMPS,
CONCRETE WEARCOURSE, WATERPROOFING, GUARD RAILS, AND HANDRAILS, UNLESS
SPECIFICALLY INDICATED TO REMAIN.
4. REFER TO A-104, A105, A106 FOR NEW SIDEWALK CONDITIONS. SLOPE TO MATCH EXISTING.
REFER TO CIVIL DRAWINGS.
KEYPLAN
G STREET NW
NORTH CAPITOL STREET NW
N
US GOVERNMENT PUBLISHING OFFICE
M
M
REMOVE ALL ITEMS UNLESS DESIGNATED TO REMAIN
F
C
A
E
D
B
F
C
A
E
D
B
10'±
10'±
1'-6"±
2'±
10'±
10'±
1'-6"±
2'±
8 8
7 9 8
KEYNOTES
PROVIDE SHORING AT SHEET METAL DUCTWORK AS-REQUIRED TO FACILITATE WORK.
REMOVE EXISTING BROWNSTONE CHEEK WALLS. STORE FOR RECONSTRUCTION.
REMOVE AND REPLACE EXISTING DUCTWORK.
PROTECT AND BRACE STORMWATER MANAGEMENT CURB INLET AS REQUIRED DURING
DEMOLITION AND CONSTRUCTION REFER TO CIVIL DRAWINGS
GRANITE CURB TO REMAIN AND BRICK/CONCRETE GUTTER TO REMAIN.
REMOVE, STORE, AND REINSTALL EXISTING PAVERS.
STREET LIGHT TO REMAIN DURING CONSTRUCTION.
STREET SIGN TO BE REMOVED AS REQUIRED DURING CONSTRUCTION. CONTRACTOR TO
PROVIDE TEMPORARY SIGNAGE AS REQUIRED BY DC DOT.
PARKING METER TO BE REMOVED, STORED, AND REINSTALLED.
FIRE HYDRANT TO REMAIN, HYDRANT TO BE FULLY OPERATION DURING CONSTRUCTION.
TRAFFIC LIGHT TO REMAIN AND BE OPERATIONAL THROUGHOUT CONSTRUCTION.
REMOVE AND REPLACE MANHOLE/SEWER COVER, FRAME AND SEALS AS REQUIRED.
WATER VALVE TO REMAIN. REMOVE AND REPLACE COVER AND FRAMING AS REQUIRED.
REMOVE, STORE, AND REINSTALL TRASHCAN.
12'±
SIM
A-505
0 4' 8' 12'
LIGHTENING PROTECTION
TO REMAIN (TYP. OF ALL)
STREET LIGHT TO REMAIN
NORTH
A-503
A-503
A-501
21222324272829303132333536 34 26 25
5678910111213141516181920 17
345 2 01
A-501
A-501
A-103
SIDEWALK
REFLECTED
CEILING PLAN
EXISTING
CONDITIONS
3/16" = 1'
0 4' 8' 12'
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
A 1X
.D W
G
• 4
/22 /20
3:
:04
P M
M
LF
656429 A1x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
SCALE: 3/16" = 1'-0"
SIDEWALK REFLECTED CEILING PLAN1
A-103
REPAIR LEGEND
REMOVE AND REPLACE DETERIORATED
CONCRETE ENCASEMENT AT STRUCTURAL
STEEL BEAMS
REMOVE AND REPLACE DETERIORATED
CONCRETE SLAB FULL DEPTH
C
C
A
C
E
A
C
E
12'± 12'±
12'± 12'±
12'± 12'± 12'± 12'± 12'± 12'± 12'± 12'± 12'± 12'±12'± 12'± 12'±
12'± 12'± 12'± 12'± 12'± 12'± 12'± 12'± 12'± 12'± 12'± MA
TC
H
LIN
E A-
A
MA
TC
H
LIN
E A-
A
MA
TC
H
LIN
E B-
B
MA
TC
H
LIN
E B-
B
12'±
10'±
10'±
10'±
KEYPLAN
G STREET NW
NORTH CAPITOL STREET NW
N
US GOVERNMENT PUBLISHING OFFICE
1. REMOVE PAINT COATINGS AT STRUCTURAL SLAB SOFFIT AND CONCRETE ENCASED
FRAMING THROUGHOUT SIDEWALK VAULT.
2. STRUCTURAL SLAB SOFFIT AND CONCRETE ENCASED FRAMING TO RECEIVE PAINT
COATINGS UNLESS NOTED OTHERWISE.
3. AT AREAS DESIGNATED FOR CONCRETE REPAIRS, AT BEAMS AND SLABS, THE
CONTRACTOR SHALL:
A. DETACH THREADED ROD HANGERS, AND PROVIDE TEMPORARY SUPPORT AT
CITY WATER/SEWER LINES.
B. DETACH THREADED ROD HANGERS, AND PROVIDE TEMPORARY SUPPORT AT
SPRINKLER LINES.
C. DETACH ELECTRICAL CONDUIT, JUNCTION BOXES, AND LIGHT FIXTURES, AND
PROVIDE TEMPORARY SUPPORT OF SAME.
D. AT COMPLETION OF CONCRETE REPAIRS: REATTACH ALL DETACHED ITEMS AND
DISPOSE OF TEMPORARY SUPPORTS.
4. THE CONTRACTOR SHALL COORDINATE ACCESS TO LOCKED AND ALARMED ROOMS
WITH THE OWNER PRIOR TO CONSTRUCTION/DEMOLITION.
5. THE CONTRACTOR SHALL PROVIDE A SECURED COVERED AND WEATHER TIGHT
STRUCTURE OVER ALL THROUGH SLAB CONCRETE REPAIR AREAS. THE DIMENSIONS
OF THE STRUCTURE WILL BE SUFFICIENT TO ALLOW FOR ACCESS TO REPAIR AREAS.
6. REFER TO S-501 FOR STRUCTURAL REPAIR DETAILS.
GENERAL NOTES
AREAWAY STEEL DOORS
TO REMAIN
12'± 12'±12'±
12'± 12'±12'± 12'±
COLUMN TO INSIDE
WALL FACE
COLUMN TO INSIDE
WALL FACE
DRIVEWAY AND ENTRANCE ABOVE
FIRE HYDRANT PENETRATIONS
TO REMAIN
DUCT PENETRATION
TO REMAIN
DUCT PENETRATION
DUCT PENETRATION
DUCT PENETRATION
TO REMAIN
D 1'-6"±
B
2'±
D
B
2'±
1' - 6"±
A
E
12'±
10'±
D
B
2'±
1' - 6"±
CONCRETE ENCASED STRUCTURAL
STEEL BEAM TO REMAIN (TYP) BRICK MASONRY FOUNDATION
WALL TO REMAIN (TYP)
N.I.C.AREA
N.I.C.AREA
REMOVE ALL ITEMS UNLESS DESIGNATED TO REMAIN
0 4' 8' 12'
REMOVE AND REINSTALL
STEEL FENCE AS
REQUIRED.
BRICK MASONRY
FOUNDATION WALL
TO REMAIN (TYP.)
STRUCTURAL STEEL COLUMN
TO REMAIN (TYP.)
PARTITION WALL
(TO REMAIN)
A-501
A-505
A-501
NORTH
LIGHTENING PROTECTION
REMOVE AND
REINSTALL
STEEL FENCE
AS REQUIRED.
BRICK MASONRY
FOUNDATION WALL
TO REMAIN (TYP.)
BRICK MASONRY
FOUNDATION WALL
TO REMAIN (TYP.)
21222324272829303132333536 34 26 25
D D
363738
W W S
A-104
SIDEWALK PLAN
NEW
CONSTRUCTION
3/16" = 1'
0 4' 8' 12'
PR
OJ
EC
T
OW
NE
R
DATENO. DESCRIPTION BY
SHEET TITLE
DRAWING SCALE
GRAPHIC SCALE
CHECKED BY
PROJECT NO.
DESIGNED BY
DRAWN BY
CADD FILE
DRAWING NO.
DATE
IF BORDER IS LESS THAN 40" x 28" USE GRAPHIC SCALES
O:
\65
\02 D
ES
IG
N\
A 1X
.D W
G
• 4
/22 /20
3:
:05
P M
M
LF
656429 A1x
This drawing and the design and construction features disclosed are proprietary to Gale Associates, Inc. and shall not be altered or reused in whole or part without the express written permission of Gale Associates, Inc.
Copyright©2024
Gale Associates, Inc.
Engineers Architects Planners
800 Corporate Drive, Suite 341 Stafford, Virginia 22554
P 703-383-0815 F 703-884-4001 www.gainc.com
Massachusetts Maryland Connecticut Virginia New Hampshire Florida Maine
4/22/2024
DJZ
MLF
WJG
656429
W
AS
HN
IG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E
W
AS
HI
NG
TO
N, D C
2 N
OR
TH
C
AP
IT
OL
S
TR
EE
T, N
W
US
G
OV
ER
NM
EN
T
PU
BL
IS
HI
NG
O
FF
IC
E G
ST
RE
ET
S
ID
EW
AL
K
RE
PA
IR
S
1 7/8/2019 75% SUBMISSION
2 9/4/2019 MLF100% SUBMISSION
Dewberry Engineers Inc.
2101 Gaither Road, Suite 340 Rockville Maryland 20850 Phone: (301) 337-2851
FAX: (301) 258-7607
3 4/22/2024 MLF100% RESUBMISSION
ALL ITEMS ARE NEW UNLESS DESIGNATED AS EXISTING (EX)
GENERAL NOTES
1. REFER TO CIVIL DRAWINGS AND DDOT REQUIREMENTS.
2. PROVIDE SIDEWALK CONCRETE WEARCOURSE CONTROL
JOINTS AT 36" O.C. EACH WAY.
3. RESET ALL EXISTING STREET SIGNS, PARKING METERS,
SURVEY MONUMENTS AND, TRASH CANS.
4. PROVIDE SEALANT AND BACKER MATERIAL BETWEEN ALL NEW
CONCRETE PAVING AND BUILDING WALLS.
SCALE: 3/16" = 1'-0"
SIDEWALK PLAN - NEW CONSTRUCTION1
A-104
KEYPLAN
G STREET NW
NORTH CAPITOL STREET NW
N
US GOVERNMENT PUBLISHING OFFICE
A-506
A-511
A-506
A-511
CONCRETE SLAB-ON-GRADE SIDEWALK
SEE GENERAL NOTE 1 AND 2
A-511
A-506
A-506
SIDEWALK N.I.C.
GRASS AREA
N.I.C.
CONCRETE SLAB
ON GRADE APRON
SEE GENERAL NOTE 1 AND 2
ADA CONCRETE
RAMP AND LANDING
MAX SLOPE OF 1":12"
A-507
A-507
A-509
7'- 2"
7'- 2"
4'-2"
STAIR AND
LANDING
METAL RAILINGS
7'-3"
A-506
T
METAL RAILINGS
A-506
A-506
A-511
D
CONCRETE GUTTER
SEE GENERAL NOTE 1
CONCRETE DRIVEWAY
SEE GENERAL NOTE 1
4'±
MA
TC
H
LIN
E A-
A
MA
TC
H
LIN
E B-
B
MA
TC
H
LIN
E
A- A
F
C
A
E
D
B
10'±
10'±
1'-6"±
2'±
N.I.C. CONCRETE GUTTER
A-201
TYP
DN.1
A-201
TYP
KEYNOTES
PROVIDE SEALANT AND BACKER MATERIAL BETWEEN NEW AND EXISTING SLABS.
PROVIDE NEW J-VENT DUCTWORK. SEE DETAIL 6/A511.
A-511
0 4' 8' 12'
SLOPE TO MATCH
EXISTING (TYP.)
SLOPE WEAR
COURSE TO MATCH
EXISTING SLOPE (TYP.)
REINSTALL GRANITE
PAVERS AT DRIVEWAY
TO MATCH EXISTING (ALTERNATE)
28' ±
4A A-506
ALT
SIM
A-506
A-511
REPAIR LEGEND
REPAIR BRICK MASONRY AND BROWNSTONE FACADE.
TYPICAL OF ALL BRICK MASONRY FROM GRADE UP
TO SECOND FLOOR. REFER TO DETAILS ON SHEET
A-513
THE CONTRACTOR SHALL PROVIDE A SECURED
COVERED AND WEATHER TIGHT STRUCTURE OVER
ALL THROUGH SLAB CONCRETE REPAIR AREAS. THE
DIMENSIONS OF THE STRUCTURE WILL BE
SUFFICIENT TO ALLOW FOR ACCESS TO REPAIR
AREAS.
2 21
1 1 1 1
NORTH
FRAMED VALTED SIDEWALK
CONCRETE…
This is the start of the file's text. The full file is on GovTribe.