This document outlines a federal contract solicitation for construction services. The solicitation seeks general construction and alterations services to upgrade buildings 1, 19 and 21 at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. Specifically, the work includes replacing revolving and swing doors with automatic sliding doors, constructing a new vestibule, and installing interior automatic swing doors and exterior automatic sliding doors. The estimated value of the construction project is between $500,000 and $1,000,000. The solicitation is expected to be posted on February 4, 2021, with bids opening within 30-45 days thereafter. The contractor will have 120 days from receipt of notice to proceed to complete all work. Requests for the solicitation documents should be submitted by February 4, 2020. The opportunity is set aside 100% for service-disabled veteran-owned small businesses.

View the file

Other files

File Type Posted
36C25021B0025 0001.docx DOCX document
Attachment II - Revised Specifications.pdf PDF
Attachment I - Revised Drawings.pdf PDF
36C25021B0025_1.docx DOCX document
Attachment V - RFI Attachment.pdf PDF
Attachment II - Specifications.pdf PDF
Attachment IV - EMR Attachment.pdf PDF
Attachment III - DBA - IN20210002.pdf PDF
Attachment VI - JA.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BUILDING 1, 19 & 21

1481 W. 10TH ST.

INDIANAPOLIS, IN 46202

PROJECT LOCATION:

RICHARD L. ROUDEBUSH VA MEDICAL CENTER

PROJECT TITLE:

UPGRADE BUILDINGS 1, 19 AND 21

ENTRANCES FOR ACCESSIBILITY

BUILDING 1 - WEST TENTH STREET ENTRANCE

BUILDING 1 - SOUTH ENTRANCE NEAR MRI

BUILDINGS 19 & 21 VESTIBULE

BUILDING NUMBER:

1, 19 & 21

STATION PROJECT NO. 583-19-205

PROJECT NUMBERS:

V U.S. Department of Veterans Affairs A

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

ARCHITECT & ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

ENGINEERS + CONSULTANTS:

AutoCAD SHX Text

INDIANAPOLIS, INDIANA

AutoCAD SHX Text

UPGRADE

AutoCAD SHX Text

BUILDINGS 1, 19 AND 21

AutoCAD SHX Text 04/10/2020

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text

35%%% SCHEMATICS DESIGN SUBMITTAL

AutoCAD SHX Text 02/18/2016

AutoCAD SHX Text

AutoCAD SHX Text

65%%% DESIGN DEVELOPMENT SUBMITTAL

AutoCAD SHX Text 02/02/2017

AutoCAD SHX Text

95%%% CONSTRUCTION DOCUMENTS SUBMITTAL

AutoCAD SHX Text 06/26/2017

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text 04/30/2018

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text 1, 19, 21

AutoCAD SHX Text 583-19-205

AutoCAD SHX Text

ENTRANCES FOR ACCESSIBILITY

AutoCAD SHX Text

GI001

AutoCAD SHX Text

SITE

AutoCAD SHX Text

REVISED PER MARY'S NOTES

AutoCAD SHX Text 04/10/2020

Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

ARCHITECT & ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

ENGINEERS + CONSULTANTS:

AutoCAD SHX Text

INDIANAPOLIS, INDIANA

AutoCAD SHX Text

UPGRADE

AutoCAD SHX Text

BUILDING 1 ACCESSIBILITY

AutoCAD SHX Text 04/10/2020

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text

35%%% SCHEMATICS DESIGN SUBMITTAL

AutoCAD SHX Text 02/18/2016

AutoCAD SHX Text

AutoCAD SHX Text

65%%% DESIGN DEVELOPMENT SUBMITTAL

AutoCAD SHX Text 02/02/2017

AutoCAD SHX Text

95%%% CONSTRUCTION DOCUMENTS SUBMITTAL

AutoCAD SHX Text 06/26/2017

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text 04/30/2018

AutoCAD SHX Text X X X X X (X)

AutoCAD SHX Text

PROJECT DESIGNATOR

AutoCAD SHX Text

SHEET NUMBER PER NATIONAL CAD STANDARD

AutoCAD SHX Text

DISCIPLINE DESIGNATOR (LEVEL 2)

AutoCAD SHX Text

PROJECT DESIGNATOR: (G)-WEST TENTH STREET ENTRANCE (I)-BUILDINGS 19 & 21

AutoCAD SHX Text DISCIPLINE DESIGNATOR (LEVEL 1) G-GENERAL C-CIVIL L-LANDSCAPE S-STRUCTURAL A-ARCHITECTURAL F-FIRE PROTECTION P-PLUMBING M-MECHANICAL E-ELECTRICAL (LEVEL 2) D-DEMOLITION (FOR ALL DISCIPLINES) VF- CG-CIVIL GRADING SI-STRUCTURAL INFORMATION SF-STRUCTURAL FRAMING PG-PROCESS GASSES

AutoCAD SHX Text

SHEET IDENTIFICATION

AutoCAD SHX Text

DISCIPLINE DESIGNATOR (LEVEL 1)

AutoCAD SHX Text

DRAWING INDEX

AutoCAD SHX Text 1, 19, 21

AutoCAD SHX Text 583-15-110

AutoCAD SHX Text

GI002

AutoCAD SHX Text

DRAWING INDEX

AutoCAD SHX Text

DRAWING NUMBER

AutoCAD SHX Text

DRAWING TITLE

AutoCAD SHX Text

GENERAL

AutoCAD SHX Text

GI001

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

GI002

AutoCAD SHX Text

DRAWING INDEX

AutoCAD SHX Text

GI003

AutoCAD SHX Text

TYPICAL ICRA CLASS III

AutoCAD SHX Text

GI600

AutoCAD SHX Text

DOOR SCHEDULE AND DETAILS

AutoCAD SHX Text

GI610

AutoCAD SHX Text

FINISH SCHEDULE AND LEGEND

AutoCAD SHX Text

GE001

AutoCAD SHX Text

ELECTRICAL NOTES AND TABLES

AutoCAD SHX Text

GE002

AutoCAD SHX Text

ELECTRICAL GENERAL NOTES, DETAILS + SYMBOLS

AutoCAD SHX Text

WEST TENTH STREET ENTRANCE (G): ARCHITECTURAL

AutoCAD SHX Text

AD101 (G)

AutoCAD SHX Text

FIRST FLOOR DEMOLITION PLAN

AutoCAD SHX Text

AS101 (G)

AutoCAD SHX Text

FIRST FLOOR FLOOR PLAN

AutoCAD SHX Text

AS401 (G)

AutoCAD SHX Text

INTERIOR ELEVATIONS & DETAILS

AutoCAD SHX Text

WEST TENTH STREET ENTRANCE (G): ELECTRICAL

AutoCAD SHX Text

ED101 (G)

AutoCAD SHX Text

FIRST FLOOR ELECTRICAL POWER AND LIGHTING DEMO PLAN

AutoCAD SHX Text

EP101 (G)

AutoCAD SHX Text

FIRST FLOOR ELECTRICAL POWER AND LIGHTING PLAN

AutoCAD SHX Text

BUILDING 19 AND 21 VESTIBULE: ARCHITECTURAL

AutoCAD SHX Text A101 (I)

AutoCAD SHX Text

FLOOR PLAN, DEMO PLAN, DEMO PHOTO & EXTERIOR ELEVATIONS

AutoCAD SHX Text A102 (I)

AutoCAD SHX Text

FLOOR PLAN, DEMO PLAN, DEMO PHOTO & EXTERIOR ELEVATIONS

AutoCAD SHX Text

BUILDING 19 AND 21 VESTIBULE: ELECTRICAL

AutoCAD SHX Text E101 (I)

AutoCAD SHX Text

FIRST FLOOR ELECTRICAL POWER DEMO AND NEW PLAN

AutoCAD SHX Text E102 (I)

AutoCAD SHX Text

FIRST FLOOR ELECTRICAL POWER DEMO AND NEW PLAN

AutoCAD SHX Text

BUILDING 1-SOUTH ENTRANCE NEAR MRI (H) - ARCHITECTURAL

AutoCAD SHX Text A103 (H)

AutoCAD SHX Text

FIRST FLOOR DEMO/PLAN & EXTERIOR ELEVATIONS

AutoCAD SHX Text A103A (H)

AutoCAD SHX Text

FIRST FLOOR DEMO/PLAN & EXTERIOR ELEVATIONS

AutoCAD SHX Text

REVISIONS PER MARY'S NOTES

TYPICAL ALTERNATIVE

CONSTRUCTION LAYOUT

CLASS III

ROOM ELEVATION

AREA UNDER

FRAMED

PICTURE

OF

C.O.R.

ICRA, ILSM

FIRE WATCH

MISC. FORMS

PAPER

CADDY

CONSTRUCTION

RESTRICTED AREA

THIS IS A

CONST. SUPERVISOR

NAME AND

CELL PHONE

XXXXXX XXXX XXXX

CHILLER PLANT AFTER HOURS

CONTACT PHONE 82329

FIRE EMERGENCY DIAL 911

XXXXXX XXXX XXXX

XXXXXX XXXX XXXX

WITH CONTACT

INFORMATION

LOW RISK

OFFICE AREAS

PATIENT RISK GROUPS

MEDIUM RISK HIGH RISK HIGHEST RISK

CARDIOLOGY CCU ANY AREA CARING FOR

ECHOCARDIOGRAPHY

ENDOSCOPY

NUCLEAR MEDICINE

PHYSICAL THERAPY

RADIOLOGY/MRI

RESPIRATORY THERAPY

EMERGENCY ROOM

LABOR & DELIVERY

LABORATORY (SPECIMEN)

NEWBORN NURSERY

OUTPATIENT SURGERY

PEDIATRICS

IMMUNOCOMPROMISED PATIENTS

BURN UNIT

CARDIAC CATH LAB

CENTRAL STERILE SUPPLY

INTENSIVE CARE UNITS

MEDICAL UNIT

PHARMACY

POST ANESTHESIA CARE UNIT

SURGICAL UNITS

NEGATIVE PRESSURE ISOLATION ROOMS

ONCOLOGY

OPERATING ROOMS INCLUDING

C-SECTION ROOMS

LOW RISK GROUP

CONSTRUCTION PROJECT TYPE

MEDIUM RISK GROUP

HIGH RISK GROUP

HIGHEST RISK GROUP

RISK RELATED GROUP TYPE A TYPE B TYPE C TYPE D

I II II III/IV

II

II III/IV

III/IV

III

III/IV

IV

IV

IV

I

I

II

CONSTRUCTION PROJECT BY PATIENT RISK

IC MATRIX - CLASS OF PRECAUTIONS:

INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK

NOTE:

LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.

GENERAL NOTES:

ICRA OCCUPANCIES:

REFERENCES:

2014 LIFE SAFETY DRAWINGS:

CROSS-SECTION 'A-A'

CLASS III

1. REMOVE OR ISOLATE H.V.A.C. SYSTEM IN AREA WHERE WORK IS BEING DONE TO

PREVENT CONTAMINATION OF DUCT SYSTEM.

2. COMPLETE ALL CRITICAL BARRIERS IE. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL

AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH

PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR

VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.

3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR

FILTRATION UNITS IF INDICATED.

4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.

5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.

6. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS

INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL

DEPARTMENT AND THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL SERVICES

DEPARTMENT.

1. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS

ASSOCIATED WITH CONSTRUCTION.

2. VACUUM WORK AREA WITH HEPA FILTERED VACUUM.

4. WET MOP AREA WITH DISINFECTANT.

5. REMOVE ISOLATION OF H.V.A.C. SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.

PRIOR TO ANY CONSTRUCTION

POST CONSTRUCTION

C L A S S

II

7. PLACE A WALK-OFF MAT AND A STICKY MAT AT ENTRANCE AND EXIT WORK AREAS.

3. REMOVE AND DISCARD WALK-OFF MAT AND STICKY MAT AT ENTRY AND WORK AREAS.

8. PROVIDE INSPECTED/DATED FIRE EXTINGUISHER(S) IN THE WORK AREAS.

INSPECTION AND NON-INVASIVE ACTIVITIES

TYPE A

SMALL SCALE, SHORT DURATION ACTIVITIES

TYPE B

WHICH CREATES MINIMAL DUST.

WORK THAT GENERATES A MODERATE TO

TYPE C

HIGH LEVEL OF DUST OR REQUIRES DEMOLITION

OR REMOVAL OF ANY FIXED BUILDING

COMPONENTS OR ASSEMBLIES

MAJOR DEMOLITION AND CONSTRUCTION

TYPE D

PROJECTS

MATRIX OF PRECAUTIONS FOR

CONSTRUCTION & RENOVATION

I R AC (ICRA)

LOCKING DEVICES DETAIL

CLASS III

HEPA FILTER DETAIL

CLASS III

ICRA WALL CONSTRUCTION

CLASS III

ICRA WALL CONSTRUCTION

CLASS III

PREFERRED VENDOR:

EDGEGUARD

STARC

OR

CLASS III WORK ITEMS NOTES:

TYPICAL

583-19-205

ENTRANCES

GI003

FOR ACCESSIBILITY

ICRACLASSIII

AutoCAD SHX Text

COVER ALL RETURNS

AutoCAD SHX Text

TAPE ALL SERVICES

AutoCAD SHX Text

FIRE EXTINGUISHER ON

AutoCAD SHX Text A

AutoCAD SHX Text O

AutoCAD SHX Text V

AutoCAD SHX Text

AT THE GRATE/DIFFUSERS

AutoCAD SHX Text

TO PROTECT AGAINST

AutoCAD SHX Text

PORTABLE FLOOR BRACKET

AutoCAD SHX Text

CONTAMINATION

AutoCAD SHX Text E

AutoCAD SHX Text

OUTSIDE OF BUILDING

AutoCAD SHX Text

PROVIDE STICKY MATS

AutoCAD SHX Text

(CHANGED END OF SHIFT

AutoCAD SHX Text

(ILSM MAY REQUIRE MORE

AutoCAD SHX Text

THAN ONE).

AutoCAD SHX Text

OR MORE IF NECESSARY

AutoCAD SHX Text

TO MAINTAIN CLEANLINESS).

AutoCAD SHX Text

INDICATOR MUST BE AT -0.01 OR GREATER

AutoCAD SHX Text

(VERIFY DAILY), IF NOT VERIFY ALL OPENING

AutoCAD SHX Text

SUCH AS DOORS ARE CLOSED AND/OR CHANGE

AutoCAD SHX Text

OUT NEGATIVE AIR PRE-FILTER.

AutoCAD SHX Text

POST ICRA, ILSM, FIRE INSPECTION

AutoCAD SHX Text

SHEETS VISIBLE TO PUBLIC

AutoCAD SHX Text

SUSPENDED PLASTIC ZIPPER

AutoCAD SHX Text

WALL CURTAIN BARRIER

AutoCAD SHX Text

PROVIDE STICKY MATS

AutoCAD SHX Text

(CHANGED END OF SHIFT

AutoCAD SHX Text

OR MORE IF NECESSARY

AutoCAD SHX Text

TO MAINTAIN CLEANLINESS).

AutoCAD SHX Text

WEEKLY CHANGED

AutoCAD SHX Text

(OR MORE AS NEEDED)

AutoCAD SHX Text

MONTHLY CHANGED

AutoCAD SHX Text

HEPA FILTER

AutoCAD SHX Text

PRE-FILTER

AutoCAD SHX Text

FLEX

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text

OPTIONAL EXHAUST DUCTS

AutoCAD SHX Text

(COVER THE GRATES

AutoCAD SHX Text

AND THE DIFFUSERS)

AutoCAD SHX Text

HEPA NEGATIVE AIR UNIT

AutoCAD SHX Text

DUCT

AutoCAD SHX Text

EITHER KEEP RUNNING

AutoCAD SHX Text

SUPPLY DUCTS

AutoCAD SHX Text

OR COVER WHEN RUNNING

AutoCAD SHX Text

TO KEEP DUST OUT.

AutoCAD SHX Text

APPROX. 48" A.F.F.

AutoCAD SHX Text

INDICATOR MUST BE AT -0.01 OR MORE NEGATIVE

AutoCAD SHX Text

(VERIFY DAILY), IF NOT VERIFY ALL OPENING

AutoCAD SHX Text

SUCH AS DOORS ARE CLOSED AND/OR CHANGE

AutoCAD SHX Text

OUT NEGATIVE AIR PRE-FILTER.

AutoCAD SHX Text

FIRE INSPECTION

AutoCAD SHX Text

SHEETS VISIBLE

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

XXXXXXXXXXXXXXXXX

AutoCAD SHX Text

COMING SOON!!!

AutoCAD SHX Text

INDICATOR (REFER

AutoCAD SHX Text

PERSONNEL ENTERING MUST HAVE: HARD HAT,

AutoCAD SHX Text

SAFETY GLASSES AND PROPER I.D.

AutoCAD SHX Text

-DESCRIPTION OF NEWLY PROPOSED OCCUPANCY-

AutoCAD SHX Text

TO PLAN & ELEVATION)

AutoCAD SHX Text

POST ICRA, ILSM,

AutoCAD SHX Text

TO PUBLIC

AutoCAD SHX Text

SUSPENDED

AutoCAD SHX Text

PLASTIC ZIPPER

AutoCAD SHX Text

WALL CURTAIN

AutoCAD SHX Text

BARRIER

AutoCAD SHX Text

2. ALL APPLICABLE FORMS TO BE COMPLETED AND APPROVED PRIOR TO STARTING WORK.

AutoCAD SHX Text

3. PERMITS TO INCLUDE:

AutoCAD SHX Text

ICRA, ILSM, ABOVE CEILING, FIRE SPRINKLER SYSTEM, MEDICAL GASES,

AutoCAD SHX Text

UTILITY SHUT-DOWN, FIRE/SMOKE WALL, FIRE ALARM SYSTEM.

AutoCAD SHX Text

4. THE CONSTRUCTION AREA MUST MAINTAIN A NEGATIVE PRESSURE VENTILATION.

AutoCAD SHX Text NEGATIVE AIR UNIT TO BE MAINTAINED WITH FILTER(S) REPLACEMENT PER SPECIFICATIONS.

AutoCAD SHX Text

1. ALL PERSONNEL ENTERING THE CONSTRUCTION SITE AREA MUST WEAR A HARD HAT

AutoCAD SHX Text

AND SAFETY GLASSES ALONG WITH ANY OTHER PPE REQUIRED IN THAT AREA.

AutoCAD SHX Text

CLEAN ALL EXTERIOR SURFACES OF CARTS AND TOOLS AT THE END OF EACH SHIFT.

AutoCAD SHX Text

(WEEKLY REPLACEMENT OF PRE-FILTER OR AS NECESSARY. HEPA FILTER REPLACED MONTHLY.

AutoCAD SHX Text

NEGATIVE PRESSURE MACHINES MUST BE ON AND OPERATIONAL 24/7.

AutoCAD SHX Text

MONITOR NEGATIVE PRESSURE AND POST LOG AT THE END OF EACH SHIFT.

AutoCAD SHX Text

5. CONSTRUCTION CLASS WILL BE DETERMINED BY THE CONSTRUCTION SAFETY COMITY.

AutoCAD SHX Text

6. DURING CONSTRUCTION BE CERTAIN THAT:

AutoCAD SHX Text

BARRIERS ARE INTACT AND MAINTAINED.

AutoCAD SHX Text

PARTICAL COUNT METER IS AVAILABLE.

AutoCAD SHX Text

NEGATIVE INDICATOR IS AVAILABLE.

AutoCAD SHX Text

ICRA REQUIREMENTS ARE INTACT AND

AutoCAD SHX Text

VERIFY ARE BEING MAINTAINED.

AutoCAD SHX Text

7. DIRECTIONS TO FIND REFERENCE DRAWINGS:

AutoCAD SHX Text

8. S:DRIVE/ARCHITECTURAL/ENGINEERING CADD CONTROL CENTER/(A) AS-BUILTS/ICRA OCCUPANCIES.

AutoCAD SHX Text

9. S:DRIVE/ARCHITECTURAL/ENGINEERING CADD CONTROL CENTER/(A) AS-BUILTS/2014 LIFE SAFETY DRWGS.

AutoCAD SHX Text

EXISTING AIR PLENUM

AutoCAD SHX Text

EXISTING CONCRETE SLAB FLOORING

AutoCAD SHX Text

FIRE/U.L. RATED PLASTIC

AutoCAD SHX Text

TO PREVENT DUST

AutoCAD SHX Text

FIRE/U.L. RATED PLASTIC

AutoCAD SHX Text

TO PREVENT DUST

AutoCAD SHX Text

EXISTING WALL

AutoCAD SHX Text

EXISTING WALL

AutoCAD SHX Text

(INSTALL PRIOR TO

AutoCAD SHX Text

CONSTRUCTION).

AutoCAD SHX Text

PRIOR TO CONSTRUCTION).

AutoCAD SHX Text

INFILTRATION (INSTALL

AutoCAD SHX Text

SCALE: 1/2"=1'-0"

AutoCAD SHX Text

EXISTING FIRE

AutoCAD SHX Text

SPRINKLER SYSTEM

AutoCAD SHX Text

HEPA NEGATIVE AIR UNIT

AutoCAD SHX Text

NEGATIVE AIR

AutoCAD SHX Text

DUCT DAMPER

AutoCAD SHX Text

FINISHED FLOORING TO BE KEPT CLEAN.

AutoCAD SHX Text

FLOORS NOT BEING REPLACED TO BE

AutoCAD SHX Text

PROTECTED OR COVERED WITH ROSEN

AutoCAD SHX Text

PAPER/FIRE RATED PLYWOOD.

AutoCAD SHX Text

HEATED DETECTOR CUT-OFF

AutoCAD SHX Text

INCLUDES, BUT IS NOT LIMITED TO:

AutoCAD SHX Text

REMOVABLE OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO

AutoCAD SHX Text

1 TILE PER 50 SQUARE FEET.

AutoCAD SHX Text

PAINTING (BUT NOT SANDING).

AutoCAD SHX Text

WALL COVERING, ELECTRICAL TRIM, MINOR PLUMBING, AND

AutoCAD SHX Text

ACTIVITIES WHICH DO NOT GENERATE DUST OR REQUIRE CUTTING

AutoCAD SHX Text

OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL

AutoCAD SHX Text

INSPECTION.

AutoCAD SHX Text

INCLUDES, BUT IS NOT LIMITED TO:

AutoCAD SHX Text

INSTALLATION OF TELEPHONE AND COMPUTER CABLING.

AutoCAD SHX Text

ACCESS TO CHASE SPACES.

AutoCAD SHX Text

CUTTING OF WALLS OR CEILING WHERE DUST MIGRATION

AutoCAD SHX Text

CAN BE CONTROLLED.

AutoCAD SHX Text

INCLUDES, BUT IS NOT LIMITED TO:

AutoCAD SHX Text

SANDING OF WALLS FOR PAINTING OR WALL COVERING.

AutoCAD SHX Text

REMOVAL OF FLOOR COVERINGS, CEILING TILES OR CASEWORK.

AutoCAD SHX Text

NEW WALL CONSTRUCTION.

AutoCAD SHX Text

MINOR DUCT WORK OR ELECTRICAL WORK ABOVE CEILINGS.

AutoCAD SHX Text

MAJOR CABLING ACTIVITIES.

AutoCAD SHX Text

ANY ACTIVITY WHICH CANNOT BE COMPLETED WITHIN A SINGLE

AutoCAD SHX Text

WORK SHIFT.

AutoCAD SHX Text

INCLUDES, BUT IS NOT LIMITED TO:

AutoCAD SHX Text

ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK SHIFTS.

AutoCAD SHX Text

REQUIRES HEAVY DEMOLITION OR OR REMOVAL OF A

AutoCAD SHX Text

COMPLETE CABLING SYSTEM.

AutoCAD SHX Text

NEW CONSTRUCTION.

AutoCAD SHX Text

NFECTION

AutoCAD SHX Text

ONTROL

AutoCAD SHX Text

ISK

AutoCAD SHX Text

SSESSMENT

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

ARCHITECT & ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

ENGINEERS + CONSULTANTS:

AutoCAD SHX Text

INDIANAPOLIS, INDIANA

AutoCAD SHX Text

UPGRADE

AutoCAD SHX Text

BUILDINGS 1, 19 AND 21

AutoCAD SHX Text 04/10/2020

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text

35%%% SCHEMATICS DESIGN SUBMITTAL

AutoCAD SHX Text 02/18/2016

AutoCAD SHX Text

AutoCAD SHX Text

65%%% DESIGN DEVELOPMENT SUBMITTAL

AutoCAD SHX Text 02/02/2017

AutoCAD SHX Text

95%%% CONSTRUCTION DOCUMENTS SUBMITTAL

AutoCAD SHX Text 06/26/2017

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text 04/30/2018

AutoCAD SHX Text

REVISIONS PER MARY'S NOTES

AUTOMATIC BIPARTING SLIDING DOOR

AutoCAD SHX Text

AUTOMATIC SINGLE SLIDING DOOR

AutoCAD SHX Text

1" TEMPERED GLASS TYP.

AutoCAD SHX Text

ALUMINUM FRAME TYP.

AutoCAD SHX Text

AUTOMATIC SINGLE HINGED DOOR

AutoCAD SHX Text

1/4" TEMPERED GLASS TYP.

AutoCAD SHX Text

ALUMINUM FRAME TYP.

AutoCAD SHX Text

HINGED DOOR IN THE DIRECTION OF EGRESS

AutoCAD SHX Text

AUTOMATIC TELESCOPING SLIDING DOOR

AutoCAD SHX Text

1" TEMPERED GLASS TYP.

AutoCAD SHX Text

ALUMINUM FRAME TYP.

AutoCAD SHX Text

TELESCOPING SLIDING DOORS

AutoCAD SHX Text

ALUMINUM FRAME TYP.

AutoCAD SHX Text

1/4" TEMPERED GLASS TYP.

AutoCAD SHX Text

(DOOR)

AutoCAD SHX Text

AUTOMATIC SINGLE SLIDING DOOR

AutoCAD SHX Text

1" TEMPERED GLASS TYP.

AutoCAD SHX Text

ALUMINUM FRAME TYP.

AutoCAD SHX Text 112-1/2"

AutoCAD SHX Text

AUTOMATIC BIPARTING SLIDING DOOR

AutoCAD SHX Text

ALUMINUM FRAME TYP.

AutoCAD SHX Text

1/4" TEMPERED GLASS TYP.

AutoCAD SHX Text 28-1/2"

AutoCAD SHX Text 31"

AutoCAD SHX Text 28-1/2"

AutoCAD SHX Text 31"

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

ARCHITECT & ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

ENGINEERS + CONSULTANTS:

AutoCAD SHX Text

INDIANAPOLIS, INDIANA

AutoCAD SHX Text

UPGRADE

AutoCAD SHX Text

BUILDINGS 1, 19 AND 21

AutoCAD SHX Text 04/10/2020

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text

35%%% SCHEMATICS DESIGN SUBMITTAL

AutoCAD SHX Text 02/18/2016

AutoCAD SHX Text

AutoCAD SHX Text

65%%% DESIGN DEVELOPMENT SUBMITTAL

AutoCAD SHX Text 02/02/2017

AutoCAD SHX Text

95%%% CONSTRUCTION DOCUMENTS SUBMITTAL

AutoCAD SHX Text 06/26/2017

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text 04/30/2018

AutoCAD SHX Text

DOOR TYPES

AutoCAD SHX Text

DOOR & FRAME NOTES

AutoCAD SHX Text

HARDWARE NOTES

AutoCAD SHX Text

G - WEST TENTH STREET ENTRANCE AND SOUTH ENTRANCE NEAR MRI

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

FRAME

AutoCAD SHX Text

FIRE RATING LABEL

AutoCAD SHX Text

HARDWARE

AutoCAD SHX Text

DETAIL

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

MARK

AutoCAD SHX Text

WIDTH

AutoCAD SHX Text

HEIGHT

AutoCAD SHX Text

THICKNESS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

FINISH

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

GLAZING

AutoCAD SHX Text

FRAME MATERIAL

AutoCAD SHX Text

FRAME TYPE

AutoCAD SHX Text

FRAME GLAZING

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

JAMB

AutoCAD SHX Text

SILL

AutoCAD SHX Text

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

ALUM

AutoCAD SHX Text A

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

MANUFACTURER: TORMAX

AutoCAD SHX Text

I - BUILDING 19 & 21

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

FRAME

AutoCAD SHX Text

FIRE RATING LABEL

AutoCAD SHX Text

HARDWARE

AutoCAD SHX Text

DETAIL

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text

MARK

AutoCAD SHX Text

WIDTH

AutoCAD SHX Text

HEIGHT

AutoCAD SHX Text

THICKNESS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

FINISH

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

GLAZING

AutoCAD SHX Text

FRAME MATERIAL

AutoCAD SHX Text

FRAME TYPE

AutoCAD SHX Text

FRAME GLAZING

AutoCAD SHX Text

HEAD

AutoCAD SHX Text

JAMB

AutoCAD SHX Text

SILL

AutoCAD SHX Text

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text 1"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text 1"

AutoCAD SHX Text

DOOR SCHEDULE AND DETAILS

AutoCAD SHX Text 1, 19, 21

AutoCAD SHX Text 583-19-205

AutoCAD SHX Text

ENTRANCES FOR ACCESSIBILITY

AutoCAD SHX Text

GI600

AutoCAD SHX Text Revisions Per Mary's Notes

AutoCAD SHX Text 12/21/2020

AutoCAD SHX Text 101A

AutoCAD SHX Text 4-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

ALUM

AutoCAD SHX Text B

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

MANUFACTURER: TORMAX

AutoCAD SHX Text 101B

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

ALUM

AutoCAD SHX Text C

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

ALUM

AutoCAD SHX Text A

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

MANUFACTURER: BESAM

AutoCAD SHX Text

MANUFACTURER: TORMAX

AutoCAD SHX Text

MANUFACTURER: TORMAX

AutoCAD SHX Text

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

ALUM

AutoCAD SHX Text B

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

1" TEMP

AutoCAD SHX Text

BRONZE

AutoCAD SHX Text

REFLECT. GLS.

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text

1/4" TEMP

AutoCAD SHX Text

1/4" TEMP

AutoCAD SHX Text

1/4" TEMP

AutoCAD SHX Text

1" TEMP

AutoCAD SHX Text

BRONZE

AutoCAD SHX Text

REFLECT. GLS.

AutoCAD SHX Text

MANUFACTURER: TORMAX

AutoCAD SHX Text

MANUFACTURER: TORMAX

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text D1. ALL DOORS WILL BE FIELD MACHINED AND FIELD FINISHED. ALL DOORS WILL BE FIELD MACHINED AND FIELD FINISHED. D2. ALL GLAZING SHALL MEET THE REQUIREMENTS OF 2015 IBC & NFPA ALL GLAZING SHALL MEET THE REQUIREMENTS OF 2015 IBC & NFPA 101. D3. THE MAXIMUM FORCE FOR PUSHING OR PULLING A DOOR SHALL BE: THE MAXIMUM FORCE FOR PUSHING OR PULLING A DOOR SHALL BE: EXTERIOR DOOR 85 LBF INTERIOR DOOR 5 LBF SLIDING DOOR 5 LBF D4. REFER TO ELECTRICAL DRAWINGS FOR EXIT SIGNS. REFER TO ELECTRICAL DRAWINGS FOR EXIT SIGNS. D5. DOOR FRAMES SHALL BE PROVIDED WITH MANUFACTURERS STANDARD DOOR FRAMES SHALL BE PROVIDED WITH MANUFACTURERS STANDARD DOOR SILENCERS AS REQUIRED. D6. ALL DOORS AND FRAMES THAT REQUIRE A FIRE RESISTANCE RATING ALL DOORS AND FRAMES THAT REQUIRE A FIRE RESISTANCE RATING SHALL BEAR A UL LABEL BASED ON TEST PERFORMANCES IN ACCORDANCE WITH ASTM 12-152 FOR THE DEGREE OF FIRE RESISTANCE INDICATED ON DRAWINGS. D7. PROVIDE ALL EXTERIOR DOORS INSULATED MAXIMUM U-FACTOR=0.14. PROVIDE ALL EXTERIOR DOORS INSULATED MAXIMUM U-FACTOR=0.14. D8. PAINT ALL UNFINISHED OR PRIMED, EXPOSED HOLLOW METAL AT PAINT ALL UNFINISHED OR PRIMED, EXPOSED HOLLOW METAL AT EXTERIOR AND INTERIOR . D9. DOOR GLAZING SHALL BE WITH GLASS MEETING SAFETY STANDARDS DOOR GLAZING SHALL BE WITH GLASS MEETING SAFETY STANDARDS OF 16 CRF1201 AND ANSI Z97.1. NEW GLASS SHALL BE 1/4" THICK CLEAR, TEMPERED GLASS FOR INTERIOR DOORS AND 1" THICK FOR EXTERIOR DOORS.. PROVIDE SETTING BLOCKS, SPACERS AND GLAZING GASKETS AS CALLED FOR AND/OR AS REQUIRED BY THE GLASS MANUFACTURER FOR A QUALITY INSTALLATION. D10. METAL FACE SHEETS FOR EXTERIOR DOORS SHALL BE 16GA., AND METAL FACE SHEETS FOR EXTERIOR DOORS SHALL BE 16GA., AND INTERIOR DOORS SHALL BE 18 GA. D11. DOOR FRAMES SHALL BE MORTISED. REINFORCED, DRILLED AND DOOR FRAMES SHALL BE MORTISED. REINFORCED, DRILLED AND TAPPED IN SHOP AS REQUIRED TO ACCEPT FINISH HARDWARE. D12. ACCEPTABLE DOOR AND FRAME MANUFACTURERS INCLUDE THE ACCEPTABLE DOOR AND FRAME MANUFACTURERS INCLUDE THE FOLLOWING: BESAM SL500 SERIES OWNER APPROVED EQUAL D13. SWINGING DOORS: 15LBF (67 N) TO RELEASE LATCH, 30 LBF (133 SWINGING DOORS: 15LBF (67 N) TO RELEASE LATCH, 30 LBF (133 N) TO SET THE LEAF IN MOTION, AND 15 LBF (67 N) TO OPEN THE LEAF TO THE MINIMUM REQUIRED WIDTH. D14. POWER-OPERATED AND POWER-ASSISTED SWINGING DOORS: 15 LBF POWER-OPERATED AND POWER-ASSISTED SWINGING DOORS: 15 LBF (67 N) TO RELEASE THE LATCH, 50 LBF (222 N) TO SET THE LEAF IN MOTION, AND 15 LBF (67 N) TO OPEN THE LEAF TO THE MINIMUM REQUIRED WIDTH. D15. SLIDING DOORS: THE DOOR ASSEMBLY SHALL BE DESIGNED AND SLIDING DOORS: THE DOOR ASSEMBLY SHALL BE DESIGNED AND INSTALLED SO THAT, WHEN A FORCE IS APPLIED TO THE DOOR LEAF ON THE SIDE FROM WHICH EGRESS IS MADE, IT SHALL BE CAPABLE OF SWINGING FROM ANY POSITION TO PROVIDE FULL USE OF THE REQUIRED WIDTH OF THE OPENING IN WHICH IT IS INSTALLED. D16. POWER-OPERATED AND POWER-ASSISTED DOORS, BOTH SWINGING POWER-OPERATED AND POWER-ASSISTED DOORS, BOTH SWINGING AND SLIDING, ARE REQUIRED TO BE EQUIPPED WITH A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS THAN 1 IN. (25 MM) HIGH ON A CONTRASTING BACKGROUND THAT READS AS FOLLOWS SHALL BE LOCATED ON THE EGRESS SIDE OF EACH DOOR OPENING: IN EMERGENCY, PUSH TO OPEN.

AutoCAD SHX Text

AutoCAD SHX Text D17.

AutoCAD SHX Text

SLIDER DOORS OPERATORS TO BE TORMAX.

AutoCAD SHX Text D18.

AutoCAD SHX Text

SWING DOORS OPERATORS TO BE BESAM.

AutoCAD SHX Text

AutoCAD SHX Text

DOORS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

DOORS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text 101A

AutoCAD SHX Text

AND

AutoCAD SHX Text

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DETAIL

AutoCAD SHX Text H1. SEE HARDWARE SPECIFICATION FOR HARDWARE TYPES. SEE HARDWARE SPECIFICATION FOR HARDWARE TYPES. H2. CORROSION RESISTANT HARDWARE SHALL BE INSTALLED IN DOORS. CORROSION RESISTANT HARDWARE SHALL BE INSTALLED IN DOORS. H3. THE ELECTRICAL ROOMS SHALL HAVE 3 INCH HIGH LETTERING PLACED THE ELECTRICAL ROOMS SHALL HAVE 3 INCH HIGH LETTERING PLACED ON THE DOOR. H4. DOOR HARDWARE SHALL BE CAPABLE OF OPERATION WITH THE USE OF DOOR HARDWARE SHALL BE CAPABLE OF OPERATION WITH THE USE OF ONE HAND AND SHALL NOT REQUIRE TIGHT PINCHING. TIGHT GRASPING OR TWISTING OF THE WRIST TO OPERATE. H5. THRESHOLDS AT THE DOORWAY SHALL NOT EXCEED 1/4" HEIGHT FOR THRESHOLDS AT THE DOORWAY SHALL NOT EXCEED 1/4" HEIGHT FOR EXTERIOR DOORS. H6. ALL THE LOCKING HARDWARE MUST BE READILY OPERABLE FROM THE ALL THE LOCKING HARDWARE MUST BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF KEYS OR SPECIAL KNOWLEDGE OR EFFORT. H7. PAINT ALL EXISTING DOOR FRAMES AND DOORS WITH EPOXY PAINT. PAINT ALL EXISTING DOOR FRAMES AND DOORS WITH EPOXY PAINT. H8. WHERE INDICATED ON DOOR SCHEDULE; PROVIDE SURFACE MOUNTED WHERE INDICATED ON DOOR SCHEDULE; PROVIDE SURFACE MOUNTED WIRELESS 1 1/2" X 4 3/4" RECTANGULAR PUSH BOTTOM WITH TOP JAMB, PUSH SIDE MOUNTING WITH REGULAR ARM. POWER COATED ALUMINUM FINISH. H9. WHERE INDICATED ON DOOR SCHEDULE; PROVIDE KICKPLATE. MOUNT TO WHERE INDICATED ON DOOR SCHEDULE; PROVIDE KICKPLATE. MOUNT TO PUSH SIDE OF DOOR. H10. WHERE INDICATED ON DOOR SCHEDULE; PROVIDE WALL MOUNTED WHERE INDICATED ON DOOR SCHEDULE; PROVIDE WALL MOUNTED CARD-READER. COORDINATE WITH ELECTRICAL. H11. DOOR TO BE OUTFITTED WITH ALARMING FOR EMERGENCY EXIT ONLY AND DOOR TO BE OUTFITTED WITH ALARMING FOR EMERGENCY EXIT ONLY AND IDENTIFIED AS SUCH. COORDINATE WITH ELECTRICAL DRAWINGS. H12. PROVIDE MIN. (2) 54G211 KEY SWITCHES PER BI-PARTING DOOR INSTALLATION. WIRE ONE KEY SWITCH TO TURN INCOMING POWER ON/OFF. WIRE SECOND SWITCH FOR HOLD OPEN/AUTO OPERATION. PROVIDE A THIRD KEY SWITCH AT EXTERIOR DOOR 100 FOR POLICE SERVICE LOCKOUT. H13. AUTOMATIC DOOR MOTION SENSOR SHALL BE EAGLE FAMILY SERIES AS MANUF. BY BEA, INC. SWING AND SLIDER DOOR SAFETY SYSTEM SHALL BE L2R-MICROSCAN AS MANUF. BY BEA, INC.

AutoCAD SHX Text

AutoCAD SHX Text

DOOR

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

STOREFRONT

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DETAIL

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text

TEMP. GLASS

AutoCAD SHX Text

TEMP. GLASS

AutoCAD SHX Text C

AutoCAD SHX Text

SPEC.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DETAIL

AutoCAD SHX Text

MANUFACTURER: TORMAX

AutoCAD SHX Text 101C

AutoCAD SHX Text 4'-0"

AutoCAD SHX Text 7'-0"

AutoCAD SHX Text

ALUM

AutoCAD SHX Text

ALUM

AutoCAD SHX Text F

AutoCAD SHX Text

ALUM

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text N/A

AutoCAD SHX Text

HI-H13

AutoCAD SHX Text

BRONZE

AutoCAD SHX Text

REFLECT. GLS.

AutoCAD SHX Text

1/4" TEMP

AutoCAD SHX Text 101, AutoCAD SHX Text

AND

ROOM FINISH SCHEDULE (4)

Room No. Room Name

Floor Base

Walls

CEILING

RemarksNorth West South East

Material Color Material Color Material Finish Color Material Finish Color Material Finish Color Material Finish Color

Type Height

583-15-110-G WEST TENTH STREET ENTRANCE

101 LOBBY WALK-OFF WOM-1 N/A N/A N/A N/A N/A N/A

583-15-110-I BUILDING 19 & 21 ENTRANCE

100A VESTIBULE SEALER CS-1 N/A N/A N/A N/A N/A N/A

ROOM FINISH LEGEND (4)

Key

Material Manufacturer/Design Basis Product Properties Style/Color

Notes

FLOORING

WOM-1 WALK-OFF MAT

MAT'S INC or Approved Equal

CLASSIC/ALTERNATE STRIPS OF ALUMINUM SCHLUTER

FRAME, 7/16" DEEP/ALUMINUM SCRAPER BAR/WIPER STRIP.

GRAY (See AS101(G) for Additional Notes)

CS-1 SEALER

PPG or Approved Equal

WATER-BORNE ACRYLIC SEALER

Perma-Crete Plex-Seal Acrylic Clear Sealer Exterior 4-6200C/Satin Finish

WALL BASE

N/A

WALL FINISH

CEILING

N/A

MISCELLANIOUS FINISHES

101 LOBBY CERAMIC TILE

(See Below) (See Below) (See Below)

Glass Doors Glass Doors PT-1 PT-2PT-1Glass Doors Glass Doors

Gray

Agreeable

PT-1

PT-2

SHERWIN WILLIAMS

SHERWIN WILLIAMS

Eggshell/Satin

Semi-Gloss

SW 7029 Agreeable Gray

SW 2840 Hammered Silver

Walls

Trim-Including "Wooden Beams", Light Troughs, and all Wooden Casework around all openings/Wall niches

Ceramic Tile Dal-Tile

Fabrique Blanc, Portfolio Cotto, Noce

See Detail 1 (on this page)

N.T.S.

6" Border (6" x 24")

Field 6" x 24"

Dal-Tile Portfolio #PF-10 Cotto

Dal-Tile PF2424P #PF-11 Noce (24" x 24")

Dal-Tile Fabrique Blanc #P685

Run in Herring Bone Pattern

(Top Step)

P e r i m e t e r

W a l l

P e r i m e t e r

W a l l

(EXISTING TERRAZZO LOBBY FLOOR & STORE FRONT DOOR GROUT TO LOBBY)

B a l a n c e

0.6"

Balance

A

B

C

LEGEND

11'-0"

N.T.S.

(EXISTING TERRAZZO LOBBY FLOOR & STORE FRONT DOOR GROUT TO LOBBY)

N.T.S.

N.T.S.

(EMBEDDED INTO MASTIC)

(EMBEDDED INTO MASTIC)

(Top Step)

P e r i m e t e r

W a l l

P e r i m e t e r

W a l l

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

ARCHITECT & ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

ENGINEERS + CONSULTANTS:

AutoCAD SHX Text

INDIANAPOLIS, INDIANA

AutoCAD SHX Text

UPGRADE

AutoCAD SHX Text

BUILDINGS 1, 19 AND 21

AutoCAD SHX Text 04/10/2020

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text

35%%% SCHEMATICS DESIGN SUBMITTAL

AutoCAD SHX Text 02/18/2016

AutoCAD SHX Text

AutoCAD SHX Text

65%%% DESIGN DEVELOPMENT SUBMITTAL

AutoCAD SHX Text 02/02/2017

AutoCAD SHX Text

95%%% CONSTRUCTION DOCUMENTS SUBMITTAL

AutoCAD SHX Text 06/26/2017

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text 04/30/2018

AutoCAD SHX Text

FINISH SCHEDULE AND LEGEND

AutoCAD SHX Text 1, 19, 21

AutoCAD SHX Text 583-19-205

AutoCAD SHX Text

ENTRANCES FOR ACCESSIBILITY

AutoCAD SHX Text

GI610

AutoCAD SHX Text Revisions Per Mary and John B. Notations

AutoCAD SHX Text 01/07/2021

AutoCAD SHX Text

FIELD AND STEP RISERS :

AutoCAD SHX Text FLOORING - Step Threads

AutoCAD SHX Text

INNER BORDER :

AutoCAD SHX Text

PERIMETER BORDER :

AutoCAD SHX Text

NOTES :

AutoCAD SHX Text Dal-Tile, Fabrique #P-685 Blanc (TILE 'C')

AutoCAD SHX Text Dal-Tile PF2424D Portfolio 24" x 24" - Cut to depth on Steps : #PF10, COTTO

AutoCAD SHX Text

- at 6.0" Border Width and Step Tread

AutoCAD SHX Text

- Dal-Tile, Portfolio, PF11 ; Noce (TILE 'A')

AutoCAD SHX Text

- Nickle Metal Strips in the existing Checker-Board Field is 1/16" in Width.

AutoCAD SHX Text

- at 6.0" x 24"

AutoCAD SHX Text

- Herringbone pattern for the Field (TILE 'C')

AutoCAD SHX Text

- Straight Run (Horizontal) for the Risers

AutoCAD SHX Text Stagger Grout Lines with Risers.

AutoCAD SHX Text

- Dal-Tile Portfolio, #PF10, Cotto (TILE 'B')

AutoCAD SHX Text

- 6.0" x 24"

AutoCAD SHX Text

- At corners, cut at 45 Degree/Miter to meet Border that

AutoCAD SHX Text

- At 24.0" x 24.0"

AutoCAD SHX Text

- Apply/Install Manufactured Slip Resistant Metal Edge at edges of Steps.

AutoCAD SHX Text is perpendicular.

AutoCAD SHX Text

CERAMIC FLOORING LAYOUT W/COLORS DETAIL

AutoCAD SHX Text

AutoCAD SHX Text

PATTERN LAYOUT DETAIL

AutoCAD SHX Text

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text

NW

AutoCAD SHX Text

SW

AutoCAD SHX Text

NE

AutoCAD SHX Text

SE

AutoCAD SHX Text S

AutoCAD SHX Text W

AutoCAD SHX Text

SECT. DETAIL OF STEP METAL EDGE

AutoCAD SHX Text

AutoCAD SHX Text

STEP SLIP RESISTANT METAL EDGE

AutoCAD SHX Text

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

ALIGN 'CHECKERBOARD PATTERN OF 'A'

AutoCAD SHX Text

WITH CHECKERBOARD PATTERN OF ADJACENT

AutoCAD SHX Text

TERRAZZO FLOOR SURFACE IN LOBBY AREA

AutoCAD SHX Text

(TO THE SOUTH).

AutoCAD SHX Text

* HOLD GROUT LINES TO THE SAME WIDTH/

AutoCAD SHX Text

THICKNESS AS THE METAL SPACERS IN

AutoCAD SHX Text

ADJACENT TERRAZZO OF LOBBY FLOOR

AutoCAD SHX Text

(AT 1/16" THICK).

AutoCAD SHX Text

SLIP RESISTANT METAL STEP EDGE

AutoCAD SHX Text

SCHLUTER TREP - E/-EK OR LIKE PRODUCT.

AutoCAD SHX Text

A = PERIMETER/BALANCE/OUTER BORDER

AutoCAD SHX Text

OF FLOOR SURFACE AT 24" X 24".

AutoCAD SHX Text

B = INNER BORDER AT 6" X 24" AT 45 DEGREE

AutoCAD SHX Text

CUT AT ENDS.

C = FIELD TILE AT 6" X 24".

NOTES:

SPECIAL NOTES:

MOUNTING HEIGHTSDEVICE

AutoCAD SHX Text

1. ALL DIMENSIONS ARE CONSIDERED FROM FINISHED FLOOR AND, UNLESS NOTED OTHERWISE, SHALL ALL DIMENSIONS ARE CONSIDERED FROM FINISHED FLOOR AND, UNLESS NOTED OTHERWISE, SHALL NOT VARY. RAISED FLOORS SHALL BE CONSIDERED FINISHED FLOOR. 2. ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DETAILS AND MAY BE ADJUSTED TO ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DETAILS AND MAY BE ADJUSTED TO CONFORM WITH ARCHITECTURAL REQUIREMENTS AS LONG AS NO CODE RESTRICTION IS VIOLATED. 3. OUTLETS INSTALLED LOWER THAN 15" AFF (FORWARD REACH) AND 9" AFF (SIDE REACH) ARE IN OUTLETS INSTALLED LOWER THAN 15" AFF (FORWARD REACH) AND 9" AFF (SIDE REACH) ARE IN VIOLATION OF ADA. 1. EXIT SIGNS SHALL NOT BE INSTALLED IN A MANNER THAT THE SIGN WILL BLOCK FIRE ALARM VISUAL EXIT SIGNS SHALL NOT BE INSTALLED IN A MANNER THAT THE SIGN WILL BLOCK FIRE ALARM VISUAL DEVICES. 2. FOR LIGHTING FIXTURES MOUNTING HEIGHTS SEE SCHEDULE AND DRAWINGS.FOR LIGHTING FIXTURES MOUNTING HEIGHTS SEE SCHEDULE AND DRAWINGS.

AutoCAD SHX Text

48" TO HIGHEST OPERABLE PART (SIDE OR FORWARD ACCESS).

AutoCAD SHX Text 48" TO CENTERLINE OF BOX MINIMUM (TOILETS). 66" TO CENTERLINE OF BOX MAXIMUM (SHOWERS - LOCATED OUT OF SPRAY AREA).

AutoCAD SHX Text

80" TO CENTERLINE OF DEVICE OR 6" BELOW CEILING, WHICHEVER IS LOWER.

AutoCAD SHX Text

80" TO BOTTOM OF DEVICE OR NOT MORE THAN 96" TO TOP.

AutoCAD SHX Text

FIRE ALARM VISUAL ONLY DEVICE OR A COMBINATION AUDIBLE AND VISUAL DEVICE

AutoCAD SHX Text

NOT LESS THAN 90" TO TOP OR 6" BELOW CEILING, WHICH EVER IS HIGHER.

AutoCAD SHX Text

48" TO CENTERLINE OF BOX - NOT MORE THAN 5'-0" FROM EXIT.

AutoCAD SHX Text

54" TO DIAL CENTER (NON-ACCESSIBLE). 48" TO HIGHEST OPERABLE PART (ACCESSIBLE).

AutoCAD SHX Text

12" CEILING TO CENTERLINE OR 7'-0" TO CENTERLINE IF CEILING IS OVER 8'-0".

AutoCAD SHX Text AS NOTED ON DRAWINGS. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.

AutoCAD SHX Text 16" TO BOTTOM OF BOX OR AS NOTED ON DRAWINGS. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.

AutoCAD SHX Text 16" TO BOTTOM OF BOX. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.

AutoCAD SHX Text 90" TO CENTERLINE OF SIGN OR CENTERED IN WALL AREA BETWEEN TOP OF DOOR AND CEILING.

AutoCAD SHX Text

DISCONNECT SWITCHES, MOTOR STARTERS, MOTOR PUSH BUTTON STATIONS

AutoCAD SHX Text 48" TO CENTERLINE OF BOX. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.

AutoCAD SHX Text

"A" FT.

AutoCAD SHX Text

%%UNOTES:

AutoCAD SHX Text

1. TABLES ARE BASED ON EVENLY DISTRIBUTED LOAD ALLOWING A 3% VOLTAGE DROP AT LAST OUTLET. TABLES ARE BASED ON EVENLY DISTRIBUTED LOAD ALLOWING A 3% VOLTAGE DROP AT LAST OUTLET. 2. 480V MOTOR BRANCH CIRCUIT CONDUCTORS SHALL BE #12 AWG IN 3/4" C UNLESS OTHERWISE NOTED. 480V MOTOR BRANCH CIRCUIT CONDUCTORS SHALL BE #12 AWG IN 3/4" C UNLESS OTHERWISE NOTED. 3. SIZE OF CONDUCTORS ARE BASED UPON EACH MOTOR BEING FED WITH SEPARATE CONDUIT. IF CONDUCTORS SIZE OF CONDUCTORS ARE BASED UPON EACH MOTOR BEING FED WITH SEPARATE CONDUIT. IF CONDUCTORS FOR TWO MOTORS (MAX.) ARE TO BE COMBINED IN ONE CONDUIT, INCREASE THE SIZE OF CONDUCTORS AND CONDUITS PER NATIONAL ELECTRICAL CODE (NEC), TO COMPENSATE FOR CONDUCTOR DE-RATING. 4. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT.PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT.

AutoCAD SHX Text

MOUNTING HEIGHTS FOR ELECTRICAL DEVICES

AutoCAD SHX Text

WIRE SIZING TABLE

AutoCAD SHX Text

LIGHT SWITCHES, WALL MOUNTED OCCUPANCY SENSORS

AutoCAD SHX Text

WALL MOUNTED EXIT SIGNS

AutoCAD SHX Text

CEILING MOUNTED EXIT SIGNS

AutoCAD SHX Text

RECEPTACLES

AutoCAD SHX Text

SPECIAL OUTLETS OR RECEPTACLES

AutoCAD SHX Text

PLUGMOLD OR WIREMOLD

AutoCAD SHX Text

CLOCK OUTLETS

AutoCAD SHX Text

DATA/COMMUNICATION OR TELEPHONE OUTLETS

AutoCAD SHX Text

TELEPHONE OUTLETS - WALL TYPE

AutoCAD SHX Text

FIRE ALARM MANUAL PULL STATIONS

AutoCAD SHX Text

FIRE ALARM AUDIBLE ONLY DEVICE

AutoCAD SHX Text

WALL MOUNTED REMOTE INDICATOR LIGHT

AutoCAD SHX Text

AREA OF REFUGE TELEPHONE

AutoCAD SHX Text

CALL FOR AID SWITCH WITH PULL CHAIN TO FLOOR

AutoCAD SHX Text

CARD READER

AutoCAD SHX Text

INTERCOM STATION

AutoCAD SHX Text

SOUND SYSTEM VOLUME CONTROL

AutoCAD SHX Text

MICROPHONE OUTLETS

AutoCAD SHX Text

THERMOSTATS

AutoCAD SHX Text

TEMPERATURE/HUMIDITY SENSORS

AutoCAD SHX Text

60" TO CENTER LINE OF BOX.

AutoCAD SHX Text 54" TO HIGHEST OPERABLE PART (SIDE ACCESS). 48" HIGHEST OPERABLE PART (FORWARD ACCESS).

AutoCAD SHX Text

16" TO BOTTOM OF BOX.

AutoCAD SHX Text 54" TO HIGHEST OPERABLE PART (SIDE ACCESS). 48" HIGHEST OPERABLE PART (FORWARD ACCESS).

AutoCAD SHX Text 54" TO HIGHEST OPERABLE PART (SIDE ACCESS). 48" HIGHEST OPERABLE PART (FORWARD ACCESS).

AutoCAD SHX Text

SAME AS TELEPHONE - ACCESSIBLE.

AutoCAD SHX Text

16" TO BOTTOM OF BOX.

AutoCAD SHX Text

80" TO BOTTOM FIXTURE.

AutoCAD SHX Text

60" TO CENTERLINE.

AutoCAD SHX Text

IF DISTANCE (A+B) IN FEET IS: (SEE DIAGRAM AT RIGHT)

AutoCAD SHX Text

FOR 120V-20A BRANCH CIRCUITS ONLY (UNLESS NOTED OTHERWISE)

AutoCAD SHX Text USE COPPER WIRE IN METALLIC CONDUIT, AWG SIZE AS FOLLOWS ON ENTIRE CIRCUIT AND SIZE CONDUIT ACCORDINGLY.

AutoCAD SHX Text

#12 AWG (MIN.) #10 AWG #8 AWG #6 AWG (MAX.)

AutoCAD SHX Text

LAST ON CIRCUIT.

AutoCAD SHX Text

FIRST ON CIRCUIT.

AutoCAD SHX Text

PANELBOARD

AutoCAD SHX Text

1/2 WIRE LENGTH FROM FIRST TO LAST RECEPTACLE OR LIGHTING FIXTURE ON CIRCUIT.

AutoCAD SHX Text

FOR 277V-20A BRANCH CIRCUITS ONLY (UNLESS NOTED OTHERWISE)

AutoCAD SHX Text

PANELBOARD

AutoCAD SHX Text

LAST ON CIRCUIT.

AutoCAD SHX Text

1/2 WIRE LENGTH FROM FIRST TO LAST LIGHTING FIXTURE ON CIRCUIT.

AutoCAD SHX Text

#12 AWG (MIN.) #10 AWG #8 AWG #6 AWG (MAX.)

AutoCAD SHX Text 0' TO 100' TO 100' 100' 100' TO 175' TO 175' 175' 175' TO 300' TO 300' 300' 300' TO 450'TO 450'450'

AutoCAD SHX Text USE COPPER WIRE IN METALLIC CONDUIT, AWG SIZE AS FOLLOWS ON ENTIRE CIRCUIT AND SIZE CONDUIT ACCORDINGLY.

AutoCAD SHX Text

FIRST ON CIRCUIT.

AutoCAD SHX Text

"B" FT.

AutoCAD SHX Text

"B" FT.

AutoCAD SHX Text

"A" FT.

AutoCAD SHX Text

IF DISTANCE (A+B) IN FEET IS: (SEE DIAGRAM AT RIGHT)

AutoCAD SHX Text 0' TO 250' TO 250' 250' 250' TO 400' TO 400' 400' 400' TO 700' TO 700' 700' 700' TO 1000'TO 1000'1000'

AutoCAD SHX Text Drawing Title

AutoCAD SHX Text Approved: Project Director

AutoCAD SHX Text Project Title

AutoCAD SHX Text Date

AutoCAD SHX Text Location

AutoCAD SHX Text Checked

AutoCAD SHX Text Building Number

AutoCAD SHX Text Project Number

AutoCAD SHX Text Drawing Number

AutoCAD SHX Text Drawn

AutoCAD SHX Text Revisions:

AutoCAD SHX Text Date

AutoCAD SHX Text

ARCHITECT & ENGINEERS:

AutoCAD SHX Text one eighth inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text C

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text F

AutoCAD SHX Text three inches = one foot

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text one and one half inches = one foot

AutoCAD SHX Text one inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 6"

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three quarters inch = one foot

AutoCAD SHX Text one half inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text three eighths inch = one foot

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text one quarter inch = one foot

AutoCAD SHX Text

VA FORM 08-6231

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text Office of Construction and Facilities Management

AutoCAD SHX Text

ENGINEERS + CONSULTANTS:

AutoCAD SHX Text

INDIANAPOLIS, INDIANA

AutoCAD SHX Text

UPGRADE

AutoCAD SHX Text

BUILDINGS 1, 19 AND 21

AutoCAD SHX Text 04/10/2020

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text

35%%% SCHEMATICS DESIGN SUBMITTAL

AutoCAD SHX Text 02/18/2016

AutoCAD SHX Text

AutoCAD SHX Text

65%%% DESIGN DEVELOPMENT SUBMITTAL

AutoCAD SHX Text 02/02/2017

AutoCAD SHX Text

95%%% CONSTRUCTION DOCUMENTS SUBMITTAL

AutoCAD SHX Text 06/26/2017

AutoCAD SHX Text

100%%% BID DOCUMENTS

AutoCAD SHX Text 04/30/2018

AutoCAD SHX Text

ELECTRICAL NOTES AND TABLES

AutoCAD SHX Text 1, 19, 21

AutoCAD SHX Text 583-19-205

AutoCAD SHX Text

ENTRANCES FOR ACCESSIBILITY

AutoCAD SHX Text

GE001

AutoCAD SHX Text

1. CODES CODES THE WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, MUNICIPAL, STATE AND NATIONAL CODES ALONG WITH ALL APPLICABLE VA REQUIREMENTS INCLUDING THEIR DESIGN MANUAL AND GUIDES. WHERE THE CONSTRUCTION DOCUMENTS INDICATE MORE RESTRICTIVE REQUIREMENTS THE CONSTRUCTION DOCUMENTS SHALL GOVERN. HOWEVER, THE CONSTRUCTION DOCUMENTS SHALL NOT BE INTERPRETED AS AUTHORITY TO VIOLATE ANY CODE OR REGULATION.