Attachment I - Revised Drawings.pdf
PDF 25 MB Posted
- Attached to
- Z1DA--583-19-205 - Upgrade Bldgs. 1, 19 & 21
- Solicitation number
- 36C25021B0025
About this file
This document outlines a federal contract opportunity for general construction work at the Richard L. Roudebush VA Medical Center in Indianapolis, Indiana. The solicitation number is 36C25021B0025 and seeks to upgrade buildings 1, 19, and 21 by renovating entrances, adding automatic doors and storefront structures, and renovating vestibules. The work is estimated to cost between $500,000 and $1,000,000 and will be awarded as a 100% total set-aside for Service-Disabled Veteran-Owned Small Businesses. Requests for the invitation for bids should be submitted by February 4, 2020 at 12:00 PM EST. The invitation for bids is expected to be posted on or about February 4, 2021 with bids opening within 30-45 days thereafter. The selected contractor will then have 120 days from receipt of notice to proceed to complete all work. The specification and drawings will be available with the invitation for bids. The federal agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 10.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25021B0025 0001.docx | DOCX document | |
| Attachment II - Revised Specifications.pdf | ||
| 36C25021B0025_1.docx | DOCX document | |
| Attachment V - RFI Attachment.pdf | ||
| Attachment I - Drawings.pdf | ||
| Attachment II - Specifications.pdf | ||
| Attachment IV - EMR Attachment.pdf | ||
| Attachment III - DBA - IN20210002.pdf | ||
| Attachment VI - JA.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BUILDING 1, 19 & 21
1481 W. 10TH ST.
INDIANAPOLIS, IN 46202
PROJECT LOCATION:
RICHARD L. ROUDEBUSH VA MEDICAL CENTER
PROJECT TITLE:
UPGRADE BUILDINGS 1, 19 AND 21
ENTRANCES FOR ACCESSIBILITY
BUILDING 1 - WEST TENTH STREET ENTRANCE
BUILDING 1 - SOUTH ENTRANCE NEAR MRI
BUILDINGS 19 & 21 VESTIBULE
BUILDING NUMBER:
1, 19 & 21
STATION PROJECT NO. 583-19-205
PROJECT NUMBERS:
V U.S. Department of Veterans Affairs A
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
ARCHITECT & ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text
ENGINEERS + CONSULTANTS:
AutoCAD SHX Text
INDIANAPOLIS, INDIANA
AutoCAD SHX Text
UPGRADE
AutoCAD SHX Text
BUILDINGS 1, 19 AND 21
AutoCAD SHX Text 04/10/2020
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text
35%%% SCHEMATICS DESIGN SUBMITTAL
AutoCAD SHX Text 02/18/2016
AutoCAD SHX Text
AutoCAD SHX Text
65%%% DESIGN DEVELOPMENT SUBMITTAL
AutoCAD SHX Text 02/02/2017
AutoCAD SHX Text
95%%% CONSTRUCTION DOCUMENTS SUBMITTAL
AutoCAD SHX Text 06/26/2017
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text 04/30/2018
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text 1, 19, 21
AutoCAD SHX Text 583-19-205
AutoCAD SHX Text
ENTRANCES FOR ACCESSIBILITY
AutoCAD SHX Text
GI001
AutoCAD SHX Text
SITE
AutoCAD SHX Text
REVISED PER MARY'S NOTES
AutoCAD SHX Text 04/10/2020
Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
ARCHITECT & ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text
ENGINEERS + CONSULTANTS:
AutoCAD SHX Text
INDIANAPOLIS, INDIANA
AutoCAD SHX Text
UPGRADE
AutoCAD SHX Text
BUILDING 1 ACCESSIBILITY
AutoCAD SHX Text 04/10/2020
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text
35%%% SCHEMATICS DESIGN SUBMITTAL
AutoCAD SHX Text 02/18/2016
AutoCAD SHX Text
AutoCAD SHX Text
65%%% DESIGN DEVELOPMENT SUBMITTAL
AutoCAD SHX Text 02/02/2017
AutoCAD SHX Text
95%%% CONSTRUCTION DOCUMENTS SUBMITTAL
AutoCAD SHX Text 06/26/2017
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text 04/30/2018
AutoCAD SHX Text X X X X X (X)
AutoCAD SHX Text
PROJECT DESIGNATOR
AutoCAD SHX Text
SHEET NUMBER PER NATIONAL CAD STANDARD
AutoCAD SHX Text
DISCIPLINE DESIGNATOR (LEVEL 2)
AutoCAD SHX Text
PROJECT DESIGNATOR: (G)-WEST TENTH STREET ENTRANCE (I)-BUILDINGS 19 & 21
AutoCAD SHX Text DISCIPLINE DESIGNATOR (LEVEL 1) G-GENERAL C-CIVIL L-LANDSCAPE S-STRUCTURAL A-ARCHITECTURAL F-FIRE PROTECTION P-PLUMBING M-MECHANICAL E-ELECTRICAL (LEVEL 2) D-DEMOLITION (FOR ALL DISCIPLINES) VF- CG-CIVIL GRADING SI-STRUCTURAL INFORMATION SF-STRUCTURAL FRAMING PG-PROCESS GASSES
AutoCAD SHX Text
SHEET IDENTIFICATION
AutoCAD SHX Text
DISCIPLINE DESIGNATOR (LEVEL 1)
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text 1, 19, 21
AutoCAD SHX Text 583-15-110
AutoCAD SHX Text
GI002
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
DRAWING TITLE
AutoCAD SHX Text
GENERAL
AutoCAD SHX Text
GI001
AutoCAD SHX Text
COVER SHEET
AutoCAD SHX Text
GI002
AutoCAD SHX Text
DRAWING INDEX
AutoCAD SHX Text
GI003
AutoCAD SHX Text
TYPICAL ICRA CLASS III
AutoCAD SHX Text
GI600
AutoCAD SHX Text
DOOR SCHEDULE AND DETAILS
AutoCAD SHX Text
GI610
AutoCAD SHX Text
FINISH SCHEDULE AND LEGEND
AutoCAD SHX Text
GE001
AutoCAD SHX Text
ELECTRICAL NOTES AND TABLES
AutoCAD SHX Text
GE002
AutoCAD SHX Text
ELECTRICAL GENERAL NOTES, DETAILS + SYMBOLS
AutoCAD SHX Text
WEST TENTH STREET ENTRANCE (G): ARCHITECTURAL
AutoCAD SHX Text
AD101 (G)
AutoCAD SHX Text
FIRST FLOOR DEMOLITION PLAN
AutoCAD SHX Text
AS101 (G)
AutoCAD SHX Text
FIRST FLOOR FLOOR PLAN
AutoCAD SHX Text
AS401 (G)
AutoCAD SHX Text
INTERIOR ELEVATIONS & DETAILS
AutoCAD SHX Text
WEST TENTH STREET ENTRANCE (G): ELECTRICAL
AutoCAD SHX Text
ED101 (G)
AutoCAD SHX Text
FIRST FLOOR ELECTRICAL POWER AND LIGHTING DEMO PLAN
AutoCAD SHX Text
EP101 (G)
AutoCAD SHX Text
FIRST FLOOR ELECTRICAL POWER AND LIGHTING PLAN
AutoCAD SHX Text
BUILDING 19 AND 21 VESTIBULE: ARCHITECTURAL
AutoCAD SHX Text A101 (I)
AutoCAD SHX Text
FLOOR PLAN, DEMO PLAN, DEMO PHOTO & EXTERIOR ELEVATIONS
AutoCAD SHX Text A102 (I)
AutoCAD SHX Text
FLOOR PLAN, DEMO PLAN, DEMO PHOTO & EXTERIOR ELEVATIONS
AutoCAD SHX Text
BUILDING 19 AND 21 VESTIBULE: ELECTRICAL
AutoCAD SHX Text E101 (I)
AutoCAD SHX Text
FIRST FLOOR ELECTRICAL POWER DEMO AND NEW PLAN
AutoCAD SHX Text E102 (I)
AutoCAD SHX Text
FIRST FLOOR ELECTRICAL POWER DEMO AND NEW PLAN
AutoCAD SHX Text
BUILDING 1-SOUTH ENTRANCE NEAR MRI (H) - ARCHITECTURAL
AutoCAD SHX Text A103 (H)
AutoCAD SHX Text
FIRST FLOOR DEMO/PLAN & EXTERIOR ELEVATIONS
AutoCAD SHX Text A103A (H)
AutoCAD SHX Text
FIRST FLOOR DEMO/PLAN & EXTERIOR ELEVATIONS
AutoCAD SHX Text
REVISIONS PER MARY'S NOTES
TYPICAL ALTERNATIVE
CONSTRUCTION LAYOUT
CLASS III
ROOM ELEVATION
AREA UNDER
FRAMED
PICTURE
OF
C.O.R.
ICRA, ILSM
FIRE WATCH
MISC. FORMS
PAPER
CADDY
CONSTRUCTION
RESTRICTED AREA
THIS IS A
CONST. SUPERVISOR
NAME AND
CELL PHONE
XXXXXX XXXX XXXX
CHILLER PLANT AFTER HOURS
CONTACT PHONE 82329
FIRE EMERGENCY DIAL 911
XXXXXX XXXX XXXX
XXXXXX XXXX XXXX
WITH CONTACT
INFORMATION
LOW RISK
OFFICE AREAS
PATIENT RISK GROUPS
MEDIUM RISK HIGH RISK HIGHEST RISK
CARDIOLOGY CCU ANY AREA CARING FOR
ECHOCARDIOGRAPHY
ENDOSCOPY
NUCLEAR MEDICINE
PHYSICAL THERAPY
RADIOLOGY/MRI
RESPIRATORY THERAPY
EMERGENCY ROOM
LABOR & DELIVERY
LABORATORY (SPECIMEN)
NEWBORN NURSERY
OUTPATIENT SURGERY
PEDIATRICS
IMMUNOCOMPROMISED PATIENTS
BURN UNIT
CARDIAC CATH LAB
CENTRAL STERILE SUPPLY
INTENSIVE CARE UNITS
MEDICAL UNIT
PHARMACY
POST ANESTHESIA CARE UNIT
SURGICAL UNITS
NEGATIVE PRESSURE ISOLATION ROOMS
ONCOLOGY
OPERATING ROOMS INCLUDING
C-SECTION ROOMS
LOW RISK GROUP
CONSTRUCTION PROJECT TYPE
MEDIUM RISK GROUP
HIGH RISK GROUP
HIGHEST RISK GROUP
RISK RELATED GROUP TYPE A TYPE B TYPE C TYPE D
I II II III/IV
II
II III/IV
III/IV
III
III/IV
IV
IV
IV
I
I
II
CONSTRUCTION PROJECT BY PATIENT RISK
IC MATRIX - CLASS OF PRECAUTIONS:
INFECTION CONTROL APPROVAL WILL BE REQUIRED WHEN THE CONSTRUCTION ACTIVITY AND RISK
NOTE:
LEVEL INDICATE THAT CLASS III OR CLASS IV CONTROL PROCEDURES ARE NECESSARY.
GENERAL NOTES:
ICRA OCCUPANCIES:
REFERENCES:
2014 LIFE SAFETY DRAWINGS:
CROSS-SECTION 'A-A'
CLASS III
1. REMOVE OR ISOLATE H.V.A.C. SYSTEM IN AREA WHERE WORK IS BEING DONE TO
PREVENT CONTAMINATION OF DUCT SYSTEM.
2. COMPLETE ALL CRITICAL BARRIERS IE. SHEETROCK, PLYWOOD, PLASTIC, TO SEAL
AREA FROM NON-WORK AREA OR IMPLEMENT CONTROL CUBE METHOD (CART WITH
PLASTIC COVERING AND SEALED CONNECTION TO WORK SITE WITH HEPA VACUUM FOR
VACUUMING PRIOR TO EXIT) BEFORE CONSTRUCTION BEGINS.
3. MAINTAIN NEGATIVE AIR PRESSURE WITHIN WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS IF INDICATED.
4. CONTAIN CONSTRUCTION WASTE BEFORE TRANSPORT IN TIGHTLY COVERED CONTAINERS.
5. COVER TRANSPORT RECEPTACLES OR CARTS. TAPE COVERING UNLESS SOLID LID.
6. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT IS
INSPECTED BY THE OWNER'S SAFETY DEPARTMENT AND INFECTION CONTROL
DEPARTMENT AND THOROUGHLY CLEANED BY THE OWNER'S ENVIRONMENTAL SERVICES
DEPARTMENT.
1. REMOVE BARRIER MATERIALS CAREFULLY TO MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
2. VACUUM WORK AREA WITH HEPA FILTERED VACUUM.
4. WET MOP AREA WITH DISINFECTANT.
5. REMOVE ISOLATION OF H.V.A.C. SYSTEM IN AREAS WHERE WORK IS BEING PERFORMED.
PRIOR TO ANY CONSTRUCTION
POST CONSTRUCTION
C L A S S
II
7. PLACE A WALK-OFF MAT AND A STICKY MAT AT ENTRANCE AND EXIT WORK AREAS.
3. REMOVE AND DISCARD WALK-OFF MAT AND STICKY MAT AT ENTRY AND WORK AREAS.
8. PROVIDE INSPECTED/DATED FIRE EXTINGUISHER(S) IN THE WORK AREAS.
INSPECTION AND NON-INVASIVE ACTIVITIES
TYPE A
SMALL SCALE, SHORT DURATION ACTIVITIES
TYPE B
WHICH CREATES MINIMAL DUST.
WORK THAT GENERATES A MODERATE TO
TYPE C
HIGH LEVEL OF DUST OR REQUIRES DEMOLITION
OR REMOVAL OF ANY FIXED BUILDING
COMPONENTS OR ASSEMBLIES
MAJOR DEMOLITION AND CONSTRUCTION
TYPE D
PROJECTS
MATRIX OF PRECAUTIONS FOR
CONSTRUCTION & RENOVATION
I R AC (ICRA)
LOCKING DEVICES DETAIL
CLASS III
HEPA FILTER DETAIL
CLASS III
ICRA WALL CONSTRUCTION
CLASS III
ICRA WALL CONSTRUCTION
CLASS III
PREFERRED VENDOR:
EDGEGUARD
STARC
OR
CLASS III WORK ITEMS NOTES:
TYPICAL
583-19-205
ENTRANCES
GI003
FOR ACCESSIBILITY
ICRACLASSIII
AutoCAD SHX Text
COVER ALL RETURNS
AutoCAD SHX Text
TAPE ALL SERVICES
AutoCAD SHX Text
FIRE EXTINGUISHER ON
AutoCAD SHX Text A
AutoCAD SHX Text O
AutoCAD SHX Text V
AutoCAD SHX Text
AT THE GRATE/DIFFUSERS
AutoCAD SHX Text
TO PROTECT AGAINST
AutoCAD SHX Text
PORTABLE FLOOR BRACKET
AutoCAD SHX Text
CONTAMINATION
AutoCAD SHX Text E
AutoCAD SHX Text
OUTSIDE OF BUILDING
AutoCAD SHX Text
PROVIDE STICKY MATS
AutoCAD SHX Text
(CHANGED END OF SHIFT
AutoCAD SHX Text
(ILSM MAY REQUIRE MORE
AutoCAD SHX Text
THAN ONE).
AutoCAD SHX Text
OR MORE IF NECESSARY
AutoCAD SHX Text
TO MAINTAIN CLEANLINESS).
AutoCAD SHX Text
INDICATOR MUST BE AT -0.01 OR GREATER
AutoCAD SHX Text
(VERIFY DAILY), IF NOT VERIFY ALL OPENING
AutoCAD SHX Text
SUCH AS DOORS ARE CLOSED AND/OR CHANGE
AutoCAD SHX Text
OUT NEGATIVE AIR PRE-FILTER.
AutoCAD SHX Text
POST ICRA, ILSM, FIRE INSPECTION
AutoCAD SHX Text
SHEETS VISIBLE TO PUBLIC
AutoCAD SHX Text
SUSPENDED PLASTIC ZIPPER
AutoCAD SHX Text
WALL CURTAIN BARRIER
AutoCAD SHX Text
PROVIDE STICKY MATS
AutoCAD SHX Text
(CHANGED END OF SHIFT
AutoCAD SHX Text
OR MORE IF NECESSARY
AutoCAD SHX Text
TO MAINTAIN CLEANLINESS).
AutoCAD SHX Text
WEEKLY CHANGED
AutoCAD SHX Text
(OR MORE AS NEEDED)
AutoCAD SHX Text
MONTHLY CHANGED
AutoCAD SHX Text
HEPA FILTER
AutoCAD SHX Text
PRE-FILTER
AutoCAD SHX Text
FLEX
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text
OPTIONAL EXHAUST DUCTS
AutoCAD SHX Text
(COVER THE GRATES
AutoCAD SHX Text
AND THE DIFFUSERS)
AutoCAD SHX Text
HEPA NEGATIVE AIR UNIT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
EITHER KEEP RUNNING
AutoCAD SHX Text
SUPPLY DUCTS
AutoCAD SHX Text
OR COVER WHEN RUNNING
AutoCAD SHX Text
TO KEEP DUST OUT.
AutoCAD SHX Text
APPROX. 48" A.F.F.
AutoCAD SHX Text
INDICATOR MUST BE AT -0.01 OR MORE NEGATIVE
AutoCAD SHX Text
(VERIFY DAILY), IF NOT VERIFY ALL OPENING
AutoCAD SHX Text
SUCH AS DOORS ARE CLOSED AND/OR CHANGE
AutoCAD SHX Text
OUT NEGATIVE AIR PRE-FILTER.
AutoCAD SHX Text
FIRE INSPECTION
AutoCAD SHX Text
SHEETS VISIBLE
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
XXXXXXXXXXXXXXXXX
AutoCAD SHX Text
COMING SOON!!!
AutoCAD SHX Text
INDICATOR (REFER
AutoCAD SHX Text
PERSONNEL ENTERING MUST HAVE: HARD HAT,
AutoCAD SHX Text
SAFETY GLASSES AND PROPER I.D.
AutoCAD SHX Text
-DESCRIPTION OF NEWLY PROPOSED OCCUPANCY-
AutoCAD SHX Text
TO PLAN & ELEVATION)
AutoCAD SHX Text
POST ICRA, ILSM,
AutoCAD SHX Text
TO PUBLIC
AutoCAD SHX Text
SUSPENDED
AutoCAD SHX Text
PLASTIC ZIPPER
AutoCAD SHX Text
WALL CURTAIN
AutoCAD SHX Text
BARRIER
AutoCAD SHX Text
2. ALL APPLICABLE FORMS TO BE COMPLETED AND APPROVED PRIOR TO STARTING WORK.
AutoCAD SHX Text
3. PERMITS TO INCLUDE:
AutoCAD SHX Text
ICRA, ILSM, ABOVE CEILING, FIRE SPRINKLER SYSTEM, MEDICAL GASES,
AutoCAD SHX Text
UTILITY SHUT-DOWN, FIRE/SMOKE WALL, FIRE ALARM SYSTEM.
AutoCAD SHX Text
4. THE CONSTRUCTION AREA MUST MAINTAIN A NEGATIVE PRESSURE VENTILATION.
AutoCAD SHX Text NEGATIVE AIR UNIT TO BE MAINTAINED WITH FILTER(S) REPLACEMENT PER SPECIFICATIONS.
AutoCAD SHX Text
1. ALL PERSONNEL ENTERING THE CONSTRUCTION SITE AREA MUST WEAR A HARD HAT
AutoCAD SHX Text
AND SAFETY GLASSES ALONG WITH ANY OTHER PPE REQUIRED IN THAT AREA.
AutoCAD SHX Text
CLEAN ALL EXTERIOR SURFACES OF CARTS AND TOOLS AT THE END OF EACH SHIFT.
AutoCAD SHX Text
(WEEKLY REPLACEMENT OF PRE-FILTER OR AS NECESSARY. HEPA FILTER REPLACED MONTHLY.
AutoCAD SHX Text
NEGATIVE PRESSURE MACHINES MUST BE ON AND OPERATIONAL 24/7.
AutoCAD SHX Text
MONITOR NEGATIVE PRESSURE AND POST LOG AT THE END OF EACH SHIFT.
AutoCAD SHX Text
5. CONSTRUCTION CLASS WILL BE DETERMINED BY THE CONSTRUCTION SAFETY COMITY.
AutoCAD SHX Text
6. DURING CONSTRUCTION BE CERTAIN THAT:
AutoCAD SHX Text
BARRIERS ARE INTACT AND MAINTAINED.
AutoCAD SHX Text
PARTICAL COUNT METER IS AVAILABLE.
AutoCAD SHX Text
NEGATIVE INDICATOR IS AVAILABLE.
AutoCAD SHX Text
ICRA REQUIREMENTS ARE INTACT AND
AutoCAD SHX Text
VERIFY ARE BEING MAINTAINED.
AutoCAD SHX Text
7. DIRECTIONS TO FIND REFERENCE DRAWINGS:
AutoCAD SHX Text
8. S:DRIVE/ARCHITECTURAL/ENGINEERING CADD CONTROL CENTER/(A) AS-BUILTS/ICRA OCCUPANCIES.
AutoCAD SHX Text
9. S:DRIVE/ARCHITECTURAL/ENGINEERING CADD CONTROL CENTER/(A) AS-BUILTS/2014 LIFE SAFETY DRWGS.
AutoCAD SHX Text
EXISTING AIR PLENUM
AutoCAD SHX Text
EXISTING CONCRETE SLAB FLOORING
AutoCAD SHX Text
FIRE/U.L. RATED PLASTIC
AutoCAD SHX Text
TO PREVENT DUST
AutoCAD SHX Text
FIRE/U.L. RATED PLASTIC
AutoCAD SHX Text
TO PREVENT DUST
AutoCAD SHX Text
EXISTING WALL
AutoCAD SHX Text
EXISTING WALL
AutoCAD SHX Text
(INSTALL PRIOR TO
AutoCAD SHX Text
CONSTRUCTION).
AutoCAD SHX Text
PRIOR TO CONSTRUCTION).
AutoCAD SHX Text
INFILTRATION (INSTALL
AutoCAD SHX Text
SCALE: 1/2"=1'-0"
AutoCAD SHX Text
EXISTING FIRE
AutoCAD SHX Text
SPRINKLER SYSTEM
AutoCAD SHX Text
HEPA NEGATIVE AIR UNIT
AutoCAD SHX Text
NEGATIVE AIR
AutoCAD SHX Text
DUCT DAMPER
AutoCAD SHX Text
FINISHED FLOORING TO BE KEPT CLEAN.
AutoCAD SHX Text
FLOORS NOT BEING REPLACED TO BE
AutoCAD SHX Text
PROTECTED OR COVERED WITH ROSEN
AutoCAD SHX Text
PAPER/FIRE RATED PLYWOOD.
AutoCAD SHX Text
HEATED DETECTOR CUT-OFF
AutoCAD SHX Text
INCLUDES, BUT IS NOT LIMITED TO:
AutoCAD SHX Text
REMOVABLE OF CEILING TILES FOR VISUAL INSPECTION LIMITED TO
AutoCAD SHX Text
1 TILE PER 50 SQUARE FEET.
AutoCAD SHX Text
PAINTING (BUT NOT SANDING).
AutoCAD SHX Text
WALL COVERING, ELECTRICAL TRIM, MINOR PLUMBING, AND
AutoCAD SHX Text
ACTIVITIES WHICH DO NOT GENERATE DUST OR REQUIRE CUTTING
AutoCAD SHX Text
OF WALLS OR ACCESS TO CEILINGS OTHER THAN FOR VISUAL
AutoCAD SHX Text
INSPECTION.
AutoCAD SHX Text
INCLUDES, BUT IS NOT LIMITED TO:
AutoCAD SHX Text
INSTALLATION OF TELEPHONE AND COMPUTER CABLING.
AutoCAD SHX Text
ACCESS TO CHASE SPACES.
AutoCAD SHX Text
CUTTING OF WALLS OR CEILING WHERE DUST MIGRATION
AutoCAD SHX Text
CAN BE CONTROLLED.
AutoCAD SHX Text
INCLUDES, BUT IS NOT LIMITED TO:
AutoCAD SHX Text
SANDING OF WALLS FOR PAINTING OR WALL COVERING.
AutoCAD SHX Text
REMOVAL OF FLOOR COVERINGS, CEILING TILES OR CASEWORK.
AutoCAD SHX Text
NEW WALL CONSTRUCTION.
AutoCAD SHX Text
MINOR DUCT WORK OR ELECTRICAL WORK ABOVE CEILINGS.
AutoCAD SHX Text
MAJOR CABLING ACTIVITIES.
AutoCAD SHX Text
ANY ACTIVITY WHICH CANNOT BE COMPLETED WITHIN A SINGLE
AutoCAD SHX Text
WORK SHIFT.
AutoCAD SHX Text
INCLUDES, BUT IS NOT LIMITED TO:
AutoCAD SHX Text
ACTIVITIES WHICH REQUIRE CONSECUTIVE WORK SHIFTS.
AutoCAD SHX Text
REQUIRES HEAVY DEMOLITION OR OR REMOVAL OF A
AutoCAD SHX Text
COMPLETE CABLING SYSTEM.
AutoCAD SHX Text
NEW CONSTRUCTION.
AutoCAD SHX Text
NFECTION
AutoCAD SHX Text
ONTROL
AutoCAD SHX Text
ISK
AutoCAD SHX Text
SSESSMENT
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
ARCHITECT & ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text
ENGINEERS + CONSULTANTS:
AutoCAD SHX Text
INDIANAPOLIS, INDIANA
AutoCAD SHX Text
UPGRADE
AutoCAD SHX Text
BUILDINGS 1, 19 AND 21
AutoCAD SHX Text 04/10/2020
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text
35%%% SCHEMATICS DESIGN SUBMITTAL
AutoCAD SHX Text 02/18/2016
AutoCAD SHX Text
AutoCAD SHX Text
65%%% DESIGN DEVELOPMENT SUBMITTAL
AutoCAD SHX Text 02/02/2017
AutoCAD SHX Text
95%%% CONSTRUCTION DOCUMENTS SUBMITTAL
AutoCAD SHX Text 06/26/2017
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text 04/30/2018
AutoCAD SHX Text
REVISIONS PER MARY'S NOTES
AUTOMATIC BIPARTING SLIDING DOOR
AutoCAD SHX Text
AUTOMATIC SINGLE SLIDING DOOR
AutoCAD SHX Text
1" TEMPERED GLASS TYP.
AutoCAD SHX Text
ALUMINUM FRAME TYP.
AutoCAD SHX Text
AUTOMATIC SINGLE HINGED DOOR
AutoCAD SHX Text
1/4" TEMPERED GLASS TYP.
AutoCAD SHX Text
ALUMINUM FRAME TYP.
AutoCAD SHX Text
HINGED DOOR IN THE DIRECTION OF EGRESS
AutoCAD SHX Text
AUTOMATIC TELESCOPING SLIDING DOOR
AutoCAD SHX Text
1" TEMPERED GLASS TYP.
AutoCAD SHX Text
ALUMINUM FRAME TYP.
AutoCAD SHX Text
TELESCOPING SLIDING DOORS
AutoCAD SHX Text
ALUMINUM FRAME TYP.
AutoCAD SHX Text
1/4" TEMPERED GLASS TYP.
AutoCAD SHX Text
(DOOR)
AutoCAD SHX Text
AUTOMATIC SINGLE SLIDING DOOR
AutoCAD SHX Text
1" TEMPERED GLASS TYP.
AutoCAD SHX Text
ALUMINUM FRAME TYP.
AutoCAD SHX Text 112-1/2"
AutoCAD SHX Text
AUTOMATIC BIPARTING SLIDING DOOR
AutoCAD SHX Text
ALUMINUM FRAME TYP.
AutoCAD SHX Text
1/4" TEMPERED GLASS TYP.
AutoCAD SHX Text 28-1/2"
AutoCAD SHX Text 31"
AutoCAD SHX Text 28-1/2"
AutoCAD SHX Text 31"
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
ARCHITECT & ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text
ENGINEERS + CONSULTANTS:
AutoCAD SHX Text
INDIANAPOLIS, INDIANA
AutoCAD SHX Text
UPGRADE
AutoCAD SHX Text
BUILDINGS 1, 19 AND 21
AutoCAD SHX Text 04/10/2020
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text
35%%% SCHEMATICS DESIGN SUBMITTAL
AutoCAD SHX Text 02/18/2016
AutoCAD SHX Text
AutoCAD SHX Text
65%%% DESIGN DEVELOPMENT SUBMITTAL
AutoCAD SHX Text 02/02/2017
AutoCAD SHX Text
95%%% CONSTRUCTION DOCUMENTS SUBMITTAL
AutoCAD SHX Text 06/26/2017
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text 04/30/2018
AutoCAD SHX Text
DOOR TYPES
AutoCAD SHX Text
DOOR & FRAME NOTES
AutoCAD SHX Text
HARDWARE NOTES
AutoCAD SHX Text
G - WEST TENTH STREET ENTRANCE AND SOUTH ENTRANCE NEAR MRI
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
FIRE RATING LABEL
AutoCAD SHX Text
HARDWARE
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
MARK
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
THICKNESS
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
GLAZING
AutoCAD SHX Text
FRAME MATERIAL
AutoCAD SHX Text
FRAME TYPE
AutoCAD SHX Text
FRAME GLAZING
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
SILL
AutoCAD SHX Text
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
ALUM
AutoCAD SHX Text A
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
MANUFACTURER: TORMAX
AutoCAD SHX Text
I - BUILDING 19 & 21
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
FRAME
AutoCAD SHX Text
FIRE RATING LABEL
AutoCAD SHX Text
HARDWARE
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
MARK
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
THICKNESS
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
FINISH
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
GLAZING
AutoCAD SHX Text
FRAME MATERIAL
AutoCAD SHX Text
FRAME TYPE
AutoCAD SHX Text
FRAME GLAZING
AutoCAD SHX Text
HEAD
AutoCAD SHX Text
JAMB
AutoCAD SHX Text
SILL
AutoCAD SHX Text
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text 1"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 1"
AutoCAD SHX Text
DOOR SCHEDULE AND DETAILS
AutoCAD SHX Text 1, 19, 21
AutoCAD SHX Text 583-19-205
AutoCAD SHX Text
ENTRANCES FOR ACCESSIBILITY
AutoCAD SHX Text
GI600
AutoCAD SHX Text Revisions Per Mary's Notes
AutoCAD SHX Text 12/21/2020
AutoCAD SHX Text 101A
AutoCAD SHX Text 4-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
ALUM
AutoCAD SHX Text B
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
MANUFACTURER: TORMAX
AutoCAD SHX Text 101B
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
ALUM
AutoCAD SHX Text C
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
ALUM
AutoCAD SHX Text A
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
MANUFACTURER: BESAM
AutoCAD SHX Text
MANUFACTURER: TORMAX
AutoCAD SHX Text
MANUFACTURER: TORMAX
AutoCAD SHX Text
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
ALUM
AutoCAD SHX Text B
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
1" TEMP
AutoCAD SHX Text
BRONZE
AutoCAD SHX Text
REFLECT. GLS.
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text
1/4" TEMP
AutoCAD SHX Text
1/4" TEMP
AutoCAD SHX Text
1/4" TEMP
AutoCAD SHX Text
1" TEMP
AutoCAD SHX Text
BRONZE
AutoCAD SHX Text
REFLECT. GLS.
AutoCAD SHX Text
MANUFACTURER: TORMAX
AutoCAD SHX Text
MANUFACTURER: TORMAX
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text D1. ALL DOORS WILL BE FIELD MACHINED AND FIELD FINISHED. ALL DOORS WILL BE FIELD MACHINED AND FIELD FINISHED. D2. ALL GLAZING SHALL MEET THE REQUIREMENTS OF 2015 IBC & NFPA ALL GLAZING SHALL MEET THE REQUIREMENTS OF 2015 IBC & NFPA 101. D3. THE MAXIMUM FORCE FOR PUSHING OR PULLING A DOOR SHALL BE: THE MAXIMUM FORCE FOR PUSHING OR PULLING A DOOR SHALL BE: EXTERIOR DOOR 85 LBF INTERIOR DOOR 5 LBF SLIDING DOOR 5 LBF D4. REFER TO ELECTRICAL DRAWINGS FOR EXIT SIGNS. REFER TO ELECTRICAL DRAWINGS FOR EXIT SIGNS. D5. DOOR FRAMES SHALL BE PROVIDED WITH MANUFACTURERS STANDARD DOOR FRAMES SHALL BE PROVIDED WITH MANUFACTURERS STANDARD DOOR SILENCERS AS REQUIRED. D6. ALL DOORS AND FRAMES THAT REQUIRE A FIRE RESISTANCE RATING ALL DOORS AND FRAMES THAT REQUIRE A FIRE RESISTANCE RATING SHALL BEAR A UL LABEL BASED ON TEST PERFORMANCES IN ACCORDANCE WITH ASTM 12-152 FOR THE DEGREE OF FIRE RESISTANCE INDICATED ON DRAWINGS. D7. PROVIDE ALL EXTERIOR DOORS INSULATED MAXIMUM U-FACTOR=0.14. PROVIDE ALL EXTERIOR DOORS INSULATED MAXIMUM U-FACTOR=0.14. D8. PAINT ALL UNFINISHED OR PRIMED, EXPOSED HOLLOW METAL AT PAINT ALL UNFINISHED OR PRIMED, EXPOSED HOLLOW METAL AT EXTERIOR AND INTERIOR . D9. DOOR GLAZING SHALL BE WITH GLASS MEETING SAFETY STANDARDS DOOR GLAZING SHALL BE WITH GLASS MEETING SAFETY STANDARDS OF 16 CRF1201 AND ANSI Z97.1. NEW GLASS SHALL BE 1/4" THICK CLEAR, TEMPERED GLASS FOR INTERIOR DOORS AND 1" THICK FOR EXTERIOR DOORS.. PROVIDE SETTING BLOCKS, SPACERS AND GLAZING GASKETS AS CALLED FOR AND/OR AS REQUIRED BY THE GLASS MANUFACTURER FOR A QUALITY INSTALLATION. D10. METAL FACE SHEETS FOR EXTERIOR DOORS SHALL BE 16GA., AND METAL FACE SHEETS FOR EXTERIOR DOORS SHALL BE 16GA., AND INTERIOR DOORS SHALL BE 18 GA. D11. DOOR FRAMES SHALL BE MORTISED. REINFORCED, DRILLED AND DOOR FRAMES SHALL BE MORTISED. REINFORCED, DRILLED AND TAPPED IN SHOP AS REQUIRED TO ACCEPT FINISH HARDWARE. D12. ACCEPTABLE DOOR AND FRAME MANUFACTURERS INCLUDE THE ACCEPTABLE DOOR AND FRAME MANUFACTURERS INCLUDE THE FOLLOWING: BESAM SL500 SERIES OWNER APPROVED EQUAL D13. SWINGING DOORS: 15LBF (67 N) TO RELEASE LATCH, 30 LBF (133 SWINGING DOORS: 15LBF (67 N) TO RELEASE LATCH, 30 LBF (133 N) TO SET THE LEAF IN MOTION, AND 15 LBF (67 N) TO OPEN THE LEAF TO THE MINIMUM REQUIRED WIDTH. D14. POWER-OPERATED AND POWER-ASSISTED SWINGING DOORS: 15 LBF POWER-OPERATED AND POWER-ASSISTED SWINGING DOORS: 15 LBF (67 N) TO RELEASE THE LATCH, 50 LBF (222 N) TO SET THE LEAF IN MOTION, AND 15 LBF (67 N) TO OPEN THE LEAF TO THE MINIMUM REQUIRED WIDTH. D15. SLIDING DOORS: THE DOOR ASSEMBLY SHALL BE DESIGNED AND SLIDING DOORS: THE DOOR ASSEMBLY SHALL BE DESIGNED AND INSTALLED SO THAT, WHEN A FORCE IS APPLIED TO THE DOOR LEAF ON THE SIDE FROM WHICH EGRESS IS MADE, IT SHALL BE CAPABLE OF SWINGING FROM ANY POSITION TO PROVIDE FULL USE OF THE REQUIRED WIDTH OF THE OPENING IN WHICH IT IS INSTALLED. D16. POWER-OPERATED AND POWER-ASSISTED DOORS, BOTH SWINGING POWER-OPERATED AND POWER-ASSISTED DOORS, BOTH SWINGING AND SLIDING, ARE REQUIRED TO BE EQUIPPED WITH A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT LESS THAN 1 IN. (25 MM) HIGH ON A CONTRASTING BACKGROUND THAT READS AS FOLLOWS SHALL BE LOCATED ON THE EGRESS SIDE OF EACH DOOR OPENING: IN EMERGENCY, PUSH TO OPEN.
AutoCAD SHX Text
AutoCAD SHX Text D17.
AutoCAD SHX Text
SLIDER DOORS OPERATORS TO BE TORMAX.
AutoCAD SHX Text D18.
AutoCAD SHX Text
SWING DOORS OPERATORS TO BE BESAM.
AutoCAD SHX Text
AutoCAD SHX Text
DOORS
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DOORS
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text 101A
AutoCAD SHX Text
AND
AutoCAD SHX Text
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text H1. SEE HARDWARE SPECIFICATION FOR HARDWARE TYPES. SEE HARDWARE SPECIFICATION FOR HARDWARE TYPES. H2. CORROSION RESISTANT HARDWARE SHALL BE INSTALLED IN DOORS. CORROSION RESISTANT HARDWARE SHALL BE INSTALLED IN DOORS. H3. THE ELECTRICAL ROOMS SHALL HAVE 3 INCH HIGH LETTERING PLACED THE ELECTRICAL ROOMS SHALL HAVE 3 INCH HIGH LETTERING PLACED ON THE DOOR. H4. DOOR HARDWARE SHALL BE CAPABLE OF OPERATION WITH THE USE OF DOOR HARDWARE SHALL BE CAPABLE OF OPERATION WITH THE USE OF ONE HAND AND SHALL NOT REQUIRE TIGHT PINCHING. TIGHT GRASPING OR TWISTING OF THE WRIST TO OPERATE. H5. THRESHOLDS AT THE DOORWAY SHALL NOT EXCEED 1/4" HEIGHT FOR THRESHOLDS AT THE DOORWAY SHALL NOT EXCEED 1/4" HEIGHT FOR EXTERIOR DOORS. H6. ALL THE LOCKING HARDWARE MUST BE READILY OPERABLE FROM THE ALL THE LOCKING HARDWARE MUST BE READILY OPERABLE FROM THE EGRESS SIDE WITHOUT THE USE OF KEYS OR SPECIAL KNOWLEDGE OR EFFORT. H7. PAINT ALL EXISTING DOOR FRAMES AND DOORS WITH EPOXY PAINT. PAINT ALL EXISTING DOOR FRAMES AND DOORS WITH EPOXY PAINT. H8. WHERE INDICATED ON DOOR SCHEDULE; PROVIDE SURFACE MOUNTED WHERE INDICATED ON DOOR SCHEDULE; PROVIDE SURFACE MOUNTED WIRELESS 1 1/2" X 4 3/4" RECTANGULAR PUSH BOTTOM WITH TOP JAMB, PUSH SIDE MOUNTING WITH REGULAR ARM. POWER COATED ALUMINUM FINISH. H9. WHERE INDICATED ON DOOR SCHEDULE; PROVIDE KICKPLATE. MOUNT TO WHERE INDICATED ON DOOR SCHEDULE; PROVIDE KICKPLATE. MOUNT TO PUSH SIDE OF DOOR. H10. WHERE INDICATED ON DOOR SCHEDULE; PROVIDE WALL MOUNTED WHERE INDICATED ON DOOR SCHEDULE; PROVIDE WALL MOUNTED CARD-READER. COORDINATE WITH ELECTRICAL. H11. DOOR TO BE OUTFITTED WITH ALARMING FOR EMERGENCY EXIT ONLY AND DOOR TO BE OUTFITTED WITH ALARMING FOR EMERGENCY EXIT ONLY AND IDENTIFIED AS SUCH. COORDINATE WITH ELECTRICAL DRAWINGS. H12. PROVIDE MIN. (2) 54G211 KEY SWITCHES PER BI-PARTING DOOR INSTALLATION. WIRE ONE KEY SWITCH TO TURN INCOMING POWER ON/OFF. WIRE SECOND SWITCH FOR HOLD OPEN/AUTO OPERATION. PROVIDE A THIRD KEY SWITCH AT EXTERIOR DOOR 100 FOR POLICE SERVICE LOCKOUT. H13. AUTOMATIC DOOR MOTION SENSOR SHALL BE EAGLE FAMILY SERIES AS MANUF. BY BEA, INC. SWING AND SLIDER DOOR SAFETY SYSTEM SHALL BE L2R-MICROSCAN AS MANUF. BY BEA, INC.
AutoCAD SHX Text
AutoCAD SHX Text
DOOR
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
AutoCAD SHX Text
STOREFRONT
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text
TEMP. GLASS
AutoCAD SHX Text
TEMP. GLASS
AutoCAD SHX Text C
AutoCAD SHX Text
SPEC.
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
DETAIL
AutoCAD SHX Text
MANUFACTURER: TORMAX
AutoCAD SHX Text 101C
AutoCAD SHX Text 4'-0"
AutoCAD SHX Text 7'-0"
AutoCAD SHX Text
ALUM
AutoCAD SHX Text
ALUM
AutoCAD SHX Text F
AutoCAD SHX Text
ALUM
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text N/A
AutoCAD SHX Text
HI-H13
AutoCAD SHX Text
BRONZE
AutoCAD SHX Text
REFLECT. GLS.
AutoCAD SHX Text
1/4" TEMP
AutoCAD SHX Text 101, AutoCAD SHX Text
AND
ROOM FINISH SCHEDULE (4)
Room No. Room Name
Floor Base
Walls
CEILING
RemarksNorth West South East
Material Color Material Color Material Finish Color Material Finish Color Material Finish Color Material Finish Color
Type Height
583-15-110-G WEST TENTH STREET ENTRANCE
101 LOBBY WALK-OFF WOM-1 N/A N/A N/A N/A N/A N/A
583-15-110-I BUILDING 19 & 21 ENTRANCE
100A VESTIBULE SEALER CS-1 N/A N/A N/A N/A N/A N/A
ROOM FINISH LEGEND (4)
Key
Material Manufacturer/Design Basis Product Properties Style/Color
Notes
FLOORING
WOM-1 WALK-OFF MAT
MAT'S INC or Approved Equal
CLASSIC/ALTERNATE STRIPS OF ALUMINUM SCHLUTER
FRAME, 7/16" DEEP/ALUMINUM SCRAPER BAR/WIPER STRIP.
GRAY (See AS101(G) for Additional Notes)
CS-1 SEALER
PPG or Approved Equal
WATER-BORNE ACRYLIC SEALER
Perma-Crete Plex-Seal Acrylic Clear Sealer Exterior 4-6200C/Satin Finish
WALL BASE
N/A
WALL FINISH
CEILING
N/A
MISCELLANIOUS FINISHES
101 LOBBY CERAMIC TILE
(See Below) (See Below) (See Below)
Glass Doors Glass Doors PT-1 PT-2PT-1Glass Doors Glass Doors
Gray
Agreeable
PT-1
PT-2
SHERWIN WILLIAMS
SHERWIN WILLIAMS
Eggshell/Satin
Semi-Gloss
SW 7029 Agreeable Gray
SW 2840 Hammered Silver
Walls
Trim-Including "Wooden Beams", Light Troughs, and all Wooden Casework around all openings/Wall niches
Ceramic Tile Dal-Tile
Fabrique Blanc, Portfolio Cotto, Noce
See Detail 1 (on this page)
N.T.S.
6" Border (6" x 24")
Field 6" x 24"
Dal-Tile Portfolio #PF-10 Cotto
Dal-Tile PF2424P #PF-11 Noce (24" x 24")
Dal-Tile Fabrique Blanc #P685
Run in Herring Bone Pattern
(Top Step)
P e r i m e t e r
W a l l
P e r i m e t e r
W a l l
(EXISTING TERRAZZO LOBBY FLOOR & STORE FRONT DOOR GROUT TO LOBBY)
B a l a n c e
0.6"
Balance
A
B
C
LEGEND
11'-0"
N.T.S.
(EXISTING TERRAZZO LOBBY FLOOR & STORE FRONT DOOR GROUT TO LOBBY)
N.T.S.
N.T.S.
(EMBEDDED INTO MASTIC)
(EMBEDDED INTO MASTIC)
(Top Step)
P e r i m e t e r
W a l l
P e r i m e t e r
W a l l
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
ARCHITECT & ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text
ENGINEERS + CONSULTANTS:
AutoCAD SHX Text
INDIANAPOLIS, INDIANA
AutoCAD SHX Text
UPGRADE
AutoCAD SHX Text
BUILDINGS 1, 19 AND 21
AutoCAD SHX Text 04/10/2020
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text
35%%% SCHEMATICS DESIGN SUBMITTAL
AutoCAD SHX Text 02/18/2016
AutoCAD SHX Text
AutoCAD SHX Text
65%%% DESIGN DEVELOPMENT SUBMITTAL
AutoCAD SHX Text 02/02/2017
AutoCAD SHX Text
95%%% CONSTRUCTION DOCUMENTS SUBMITTAL
AutoCAD SHX Text 06/26/2017
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text 04/30/2018
AutoCAD SHX Text
FINISH SCHEDULE AND LEGEND
AutoCAD SHX Text 1, 19, 21
AutoCAD SHX Text 583-19-205
AutoCAD SHX Text
ENTRANCES FOR ACCESSIBILITY
AutoCAD SHX Text
GI610
AutoCAD SHX Text Revisions Per Mary and John B. Notations
AutoCAD SHX Text 01/07/2021
AutoCAD SHX Text
FIELD AND STEP RISERS :
AutoCAD SHX Text FLOORING - Step Threads
AutoCAD SHX Text
INNER BORDER :
AutoCAD SHX Text
PERIMETER BORDER :
AutoCAD SHX Text
NOTES :
AutoCAD SHX Text Dal-Tile, Fabrique #P-685 Blanc (TILE 'C')
AutoCAD SHX Text Dal-Tile PF2424D Portfolio 24" x 24" - Cut to depth on Steps : #PF10, COTTO
AutoCAD SHX Text
- at 6.0" Border Width and Step Tread
AutoCAD SHX Text
- Dal-Tile, Portfolio, PF11 ; Noce (TILE 'A')
AutoCAD SHX Text
- Nickle Metal Strips in the existing Checker-Board Field is 1/16" in Width.
AutoCAD SHX Text
- at 6.0" x 24"
AutoCAD SHX Text
- Herringbone pattern for the Field (TILE 'C')
AutoCAD SHX Text
- Straight Run (Horizontal) for the Risers
AutoCAD SHX Text Stagger Grout Lines with Risers.
AutoCAD SHX Text
- Dal-Tile Portfolio, #PF10, Cotto (TILE 'B')
AutoCAD SHX Text
- 6.0" x 24"
AutoCAD SHX Text
- At corners, cut at 45 Degree/Miter to meet Border that
AutoCAD SHX Text
- At 24.0" x 24.0"
AutoCAD SHX Text
- Apply/Install Manufactured Slip Resistant Metal Edge at edges of Steps.
AutoCAD SHX Text is perpendicular.
AutoCAD SHX Text
CERAMIC FLOORING LAYOUT W/COLORS DETAIL
AutoCAD SHX Text
AutoCAD SHX Text
PATTERN LAYOUT DETAIL
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text
NW
AutoCAD SHX Text
SW
AutoCAD SHX Text
NE
AutoCAD SHX Text
SE
AutoCAD SHX Text S
AutoCAD SHX Text W
AutoCAD SHX Text
SECT. DETAIL OF STEP METAL EDGE
AutoCAD SHX Text
AutoCAD SHX Text
STEP SLIP RESISTANT METAL EDGE
AutoCAD SHX Text
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
ALIGN 'CHECKERBOARD PATTERN OF 'A'
AutoCAD SHX Text
WITH CHECKERBOARD PATTERN OF ADJACENT
AutoCAD SHX Text
TERRAZZO FLOOR SURFACE IN LOBBY AREA
AutoCAD SHX Text
(TO THE SOUTH).
AutoCAD SHX Text
* HOLD GROUT LINES TO THE SAME WIDTH/
AutoCAD SHX Text
THICKNESS AS THE METAL SPACERS IN
AutoCAD SHX Text
ADJACENT TERRAZZO OF LOBBY FLOOR
AutoCAD SHX Text
(AT 1/16" THICK).
AutoCAD SHX Text
SLIP RESISTANT METAL STEP EDGE
AutoCAD SHX Text
SCHLUTER TREP - E/-EK OR LIKE PRODUCT.
AutoCAD SHX Text
A = PERIMETER/BALANCE/OUTER BORDER
AutoCAD SHX Text
OF FLOOR SURFACE AT 24" X 24".
AutoCAD SHX Text
B = INNER BORDER AT 6" X 24" AT 45 DEGREE
AutoCAD SHX Text
CUT AT ENDS.
C = FIELD TILE AT 6" X 24".
NOTES:
SPECIAL NOTES:
MOUNTING HEIGHTSDEVICE
AutoCAD SHX Text
1. ALL DIMENSIONS ARE CONSIDERED FROM FINISHED FLOOR AND, UNLESS NOTED OTHERWISE, SHALL ALL DIMENSIONS ARE CONSIDERED FROM FINISHED FLOOR AND, UNLESS NOTED OTHERWISE, SHALL NOT VARY. RAISED FLOORS SHALL BE CONSIDERED FINISHED FLOOR. 2. ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DETAILS AND MAY BE ADJUSTED TO ALL DIMENSIONS SHALL BE COORDINATED WITH ARCHITECTURAL DETAILS AND MAY BE ADJUSTED TO CONFORM WITH ARCHITECTURAL REQUIREMENTS AS LONG AS NO CODE RESTRICTION IS VIOLATED. 3. OUTLETS INSTALLED LOWER THAN 15" AFF (FORWARD REACH) AND 9" AFF (SIDE REACH) ARE IN OUTLETS INSTALLED LOWER THAN 15" AFF (FORWARD REACH) AND 9" AFF (SIDE REACH) ARE IN VIOLATION OF ADA. 1. EXIT SIGNS SHALL NOT BE INSTALLED IN A MANNER THAT THE SIGN WILL BLOCK FIRE ALARM VISUAL EXIT SIGNS SHALL NOT BE INSTALLED IN A MANNER THAT THE SIGN WILL BLOCK FIRE ALARM VISUAL DEVICES. 2. FOR LIGHTING FIXTURES MOUNTING HEIGHTS SEE SCHEDULE AND DRAWINGS.FOR LIGHTING FIXTURES MOUNTING HEIGHTS SEE SCHEDULE AND DRAWINGS.
AutoCAD SHX Text
48" TO HIGHEST OPERABLE PART (SIDE OR FORWARD ACCESS).
AutoCAD SHX Text 48" TO CENTERLINE OF BOX MINIMUM (TOILETS). 66" TO CENTERLINE OF BOX MAXIMUM (SHOWERS - LOCATED OUT OF SPRAY AREA).
AutoCAD SHX Text
80" TO CENTERLINE OF DEVICE OR 6" BELOW CEILING, WHICHEVER IS LOWER.
AutoCAD SHX Text
80" TO BOTTOM OF DEVICE OR NOT MORE THAN 96" TO TOP.
AutoCAD SHX Text
FIRE ALARM VISUAL ONLY DEVICE OR A COMBINATION AUDIBLE AND VISUAL DEVICE
AutoCAD SHX Text
NOT LESS THAN 90" TO TOP OR 6" BELOW CEILING, WHICH EVER IS HIGHER.
AutoCAD SHX Text
48" TO CENTERLINE OF BOX - NOT MORE THAN 5'-0" FROM EXIT.
AutoCAD SHX Text
54" TO DIAL CENTER (NON-ACCESSIBLE). 48" TO HIGHEST OPERABLE PART (ACCESSIBLE).
AutoCAD SHX Text
12" CEILING TO CENTERLINE OR 7'-0" TO CENTERLINE IF CEILING IS OVER 8'-0".
AutoCAD SHX Text AS NOTED ON DRAWINGS. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.
AutoCAD SHX Text 16" TO BOTTOM OF BOX OR AS NOTED ON DRAWINGS. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.
AutoCAD SHX Text 16" TO BOTTOM OF BOX. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.
AutoCAD SHX Text 90" TO CENTERLINE OF SIGN OR CENTERED IN WALL AREA BETWEEN TOP OF DOOR AND CEILING.
AutoCAD SHX Text
DISCONNECT SWITCHES, MOTOR STARTERS, MOTOR PUSH BUTTON STATIONS
AutoCAD SHX Text 48" TO CENTERLINE OF BOX. EXCEPTION: 44" MAXIMUM TO TOP ABOVE COUNTERS WHICH ARE 20"-25"D.
AutoCAD SHX Text
"A" FT.
AutoCAD SHX Text
%%UNOTES:
AutoCAD SHX Text
1. TABLES ARE BASED ON EVENLY DISTRIBUTED LOAD ALLOWING A 3% VOLTAGE DROP AT LAST OUTLET. TABLES ARE BASED ON EVENLY DISTRIBUTED LOAD ALLOWING A 3% VOLTAGE DROP AT LAST OUTLET. 2. 480V MOTOR BRANCH CIRCUIT CONDUCTORS SHALL BE #12 AWG IN 3/4" C UNLESS OTHERWISE NOTED. 480V MOTOR BRANCH CIRCUIT CONDUCTORS SHALL BE #12 AWG IN 3/4" C UNLESS OTHERWISE NOTED. 3. SIZE OF CONDUCTORS ARE BASED UPON EACH MOTOR BEING FED WITH SEPARATE CONDUIT. IF CONDUCTORS SIZE OF CONDUCTORS ARE BASED UPON EACH MOTOR BEING FED WITH SEPARATE CONDUIT. IF CONDUCTORS FOR TWO MOTORS (MAX.) ARE TO BE COMBINED IN ONE CONDUIT, INCREASE THE SIZE OF CONDUCTORS AND CONDUITS PER NATIONAL ELECTRICAL CODE (NEC), TO COMPENSATE FOR CONDUCTOR DE-RATING. 4. PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT.PROVIDE DEDICATED NEUTRAL FOR EACH CIRCUIT.
AutoCAD SHX Text
MOUNTING HEIGHTS FOR ELECTRICAL DEVICES
AutoCAD SHX Text
WIRE SIZING TABLE
AutoCAD SHX Text
LIGHT SWITCHES, WALL MOUNTED OCCUPANCY SENSORS
AutoCAD SHX Text
WALL MOUNTED EXIT SIGNS
AutoCAD SHX Text
CEILING MOUNTED EXIT SIGNS
AutoCAD SHX Text
RECEPTACLES
AutoCAD SHX Text
SPECIAL OUTLETS OR RECEPTACLES
AutoCAD SHX Text
PLUGMOLD OR WIREMOLD
AutoCAD SHX Text
CLOCK OUTLETS
AutoCAD SHX Text
DATA/COMMUNICATION OR TELEPHONE OUTLETS
AutoCAD SHX Text
TELEPHONE OUTLETS - WALL TYPE
AutoCAD SHX Text
FIRE ALARM MANUAL PULL STATIONS
AutoCAD SHX Text
FIRE ALARM AUDIBLE ONLY DEVICE
AutoCAD SHX Text
WALL MOUNTED REMOTE INDICATOR LIGHT
AutoCAD SHX Text
AREA OF REFUGE TELEPHONE
AutoCAD SHX Text
CALL FOR AID SWITCH WITH PULL CHAIN TO FLOOR
AutoCAD SHX Text
CARD READER
AutoCAD SHX Text
INTERCOM STATION
AutoCAD SHX Text
SOUND SYSTEM VOLUME CONTROL
AutoCAD SHX Text
MICROPHONE OUTLETS
AutoCAD SHX Text
THERMOSTATS
AutoCAD SHX Text
TEMPERATURE/HUMIDITY SENSORS
AutoCAD SHX Text
60" TO CENTER LINE OF BOX.
AutoCAD SHX Text 54" TO HIGHEST OPERABLE PART (SIDE ACCESS). 48" HIGHEST OPERABLE PART (FORWARD ACCESS).
AutoCAD SHX Text
16" TO BOTTOM OF BOX.
AutoCAD SHX Text 54" TO HIGHEST OPERABLE PART (SIDE ACCESS). 48" HIGHEST OPERABLE PART (FORWARD ACCESS).
AutoCAD SHX Text 54" TO HIGHEST OPERABLE PART (SIDE ACCESS). 48" HIGHEST OPERABLE PART (FORWARD ACCESS).
AutoCAD SHX Text
SAME AS TELEPHONE - ACCESSIBLE.
AutoCAD SHX Text
16" TO BOTTOM OF BOX.
AutoCAD SHX Text
80" TO BOTTOM FIXTURE.
AutoCAD SHX Text
60" TO CENTERLINE.
AutoCAD SHX Text
IF DISTANCE (A+B) IN FEET IS: (SEE DIAGRAM AT RIGHT)
AutoCAD SHX Text
FOR 120V-20A BRANCH CIRCUITS ONLY (UNLESS NOTED OTHERWISE)
AutoCAD SHX Text USE COPPER WIRE IN METALLIC CONDUIT, AWG SIZE AS FOLLOWS ON ENTIRE CIRCUIT AND SIZE CONDUIT ACCORDINGLY.
AutoCAD SHX Text
#12 AWG (MIN.) #10 AWG #8 AWG #6 AWG (MAX.)
AutoCAD SHX Text
LAST ON CIRCUIT.
AutoCAD SHX Text
FIRST ON CIRCUIT.
AutoCAD SHX Text
PANELBOARD
AutoCAD SHX Text
1/2 WIRE LENGTH FROM FIRST TO LAST RECEPTACLE OR LIGHTING FIXTURE ON CIRCUIT.
AutoCAD SHX Text
FOR 277V-20A BRANCH CIRCUITS ONLY (UNLESS NOTED OTHERWISE)
AutoCAD SHX Text
PANELBOARD
AutoCAD SHX Text
LAST ON CIRCUIT.
AutoCAD SHX Text
1/2 WIRE LENGTH FROM FIRST TO LAST LIGHTING FIXTURE ON CIRCUIT.
AutoCAD SHX Text
#12 AWG (MIN.) #10 AWG #8 AWG #6 AWG (MAX.)
AutoCAD SHX Text 0' TO 100' TO 100' 100' 100' TO 175' TO 175' 175' 175' TO 300' TO 300' 300' 300' TO 450'TO 450'450'
AutoCAD SHX Text USE COPPER WIRE IN METALLIC CONDUIT, AWG SIZE AS FOLLOWS ON ENTIRE CIRCUIT AND SIZE CONDUIT ACCORDINGLY.
AutoCAD SHX Text
FIRST ON CIRCUIT.
AutoCAD SHX Text
"B" FT.
AutoCAD SHX Text
"B" FT.
AutoCAD SHX Text
"A" FT.
AutoCAD SHX Text
IF DISTANCE (A+B) IN FEET IS: (SEE DIAGRAM AT RIGHT)
AutoCAD SHX Text 0' TO 250' TO 250' 250' 250' TO 400' TO 400' 400' 400' TO 700' TO 700' 700' 700' TO 1000'TO 1000'1000'
AutoCAD SHX Text Drawing Title
AutoCAD SHX Text Approved: Project Director
AutoCAD SHX Text Project Title
AutoCAD SHX Text Date
AutoCAD SHX Text Location
AutoCAD SHX Text Checked
AutoCAD SHX Text Building Number
AutoCAD SHX Text Project Number
AutoCAD SHX Text Drawing Number
AutoCAD SHX Text Drawn
AutoCAD SHX Text Revisions:
AutoCAD SHX Text Date
AutoCAD SHX Text
ARCHITECT & ENGINEERS:
AutoCAD SHX Text one eighth inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text three inches = one foot
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text one and one half inches = one foot
AutoCAD SHX Text one inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three quarters inch = one foot
AutoCAD SHX Text one half inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text three eighths inch = one foot
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text one quarter inch = one foot
AutoCAD SHX Text
VA FORM 08-6231
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text Office of Construction and Facilities Management
AutoCAD SHX Text
ENGINEERS + CONSULTANTS:
AutoCAD SHX Text
INDIANAPOLIS, INDIANA
AutoCAD SHX Text
UPGRADE
AutoCAD SHX Text
BUILDINGS 1, 19 AND 21
AutoCAD SHX Text 04/10/2020
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text
35%%% SCHEMATICS DESIGN SUBMITTAL
AutoCAD SHX Text 02/18/2016
AutoCAD SHX Text
AutoCAD SHX Text
65%%% DESIGN DEVELOPMENT SUBMITTAL
AutoCAD SHX Text 02/02/2017
AutoCAD SHX Text
95%%% CONSTRUCTION DOCUMENTS SUBMITTAL
AutoCAD SHX Text 06/26/2017
AutoCAD SHX Text
100%%% BID DOCUMENTS
AutoCAD SHX Text 04/30/2018
AutoCAD SHX Text
ELECTRICAL NOTES AND TABLES
AutoCAD SHX Text 1, 19, 21
AutoCAD SHX Text 583-19-205
AutoCAD SHX Text
ENTRANCES FOR ACCESSIBILITY
AutoCAD SHX Text
GE001
AutoCAD SHX Text
1. CODES CODES THE WORK SHALL COMPLY WITH ALL APPLICABLE LOCAL, MUNICIPAL, STATE AND NATIONAL CODES ALONG WITH ALL APPLICABLE VA REQUIREMENTS INCLUDING THEIR DESIGN MANUAL AND GUIDES. WHERE THE CONSTRUCTION DOCUMENTS INDICATE MORE RESTRICTIVE REQUIREMENTS THE CONSTRUCTION DOCUMENTS SHALL GOVERN. HOWEVER, THE CONSTRUCTION DOCUMENTS SHALL NOT BE INTERPRETED AS AUTHORITY TO VIOLATE ANY CODE OR REGULATION.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .