Attachment G - SP-POL-CMP-INSPECT-FY25-BAR Tank 5932 -Return To Service Letter.docx
DOCX document 13 KB Posted
- Attached to
- API 653 Fuel Tank Inspection, Barksdale AFB, LA
- Solicitation number
- W9128F25Q0008
About this file
This document is a Return to Service Letter for Storage Tank No. [XXXXX] located at [Location]. The tank was inspected in accordance with API STD 653 for serviceability evaluation, and was found to be in suitable condition for return to service with no mandatory repairs required. The letter provides the dates for the inspection performed, the tank's return to service, and the recommended future inspection dates for the API 653 out-of-service and in-service inspections. This Return to Service Letter is related to the federal contract opportunity W9128F25Q0008 for API 653 Fuel Tank Inspection at Barksdale AFB, LA, issued by the U.S. Army Corps of Engineers, Engineering District Omaha.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
[COMPANY Letter Head]
DATE
Subject: RETURN TO SERVICE LETTER
STORAGE TANK NO. [ XXXXX]
Fuel System Inspection, [Location] Contract No. [XXXXX], Task Order [XX] Out-of-Service [API 653] Inspection
Tank [XXX] was inspected for serviceability evaluation in accordance with the requirements of [API STD 653, XX Edition, Date.]. The Inspection was performed by [Company Name] on [ddmmmyy].
The results of the inspection: The tank is in suitable condition for return to service. There are no mandatory repairs that require immediate attention, in order to prevent imminent risk to system operators, equipment integrity, or the adjacent environment.
The Tank was returned to service on [date].
RECOMMENDED FUTURE INSPECTION DATES no later than (NLT):
| API 653 Out-Of-Service tank inspection | [date] | ||
| API 653 In-Service tank inspection | [date] | ||
| …UT Roundness…Corrosion…etc | [date] |
SATE REGULATIONS (N/A if Not Applicable):
[State] Regulations follow [……] State Regulations for API 653 Out-Of-Service tank inspections is NLT [date]
Final documents will be included in the close out documentation as required by the task order.
Prepared by:
[Inspectors Name] [Title] [Company] API 653 Certified Inspector No. [XXXX]
Installation acknowledgement:
[Installation Point of Contact Name] [Title]
[USACE Fuels Project Manager] Fuels Project Manager
USACE-NWO-PMS-C
[USACE Fuels Project Manager Email]@usace.army.mil
File details come from the government source that posted it. Updated .