Attachment G - Return To Service Letter.docx
DOCX document 13 KB Posted
- Attached to
- POL Tank Inspection ERK Eareckson Air Station
- Solicitation number
- W9128F23Q0106
About this file
This document is a return to service letter for an out-of-service API 653 inspection of a fuel storage tank at Eareckson Air Station in Alaska under solicitation number W9128F23Q0106 from the Department of the Army Corps of Engineers Engineering District Omaha. The letter documents that tank number XXX was inspected by [Company Name] on [date] in accordance with API STD 653 and was found to be in suitable condition for return to service, with no mandatory repairs requiring immediate attention. It recommends future inspection dates for an API 653 out-of-service tank inspection by [date], an API 653 in-service tank inspection by [date], and UT roundness and corrosion inspections by [date]. The letter is to be included in the close out documentation for task order [XX] under contract number [XXXXX].
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment B - Fuels Tank Storage - ERK.xlsx | XLSX spreadsheet | |
| Attachment J.1 - Facility 123_Internal_2 July 2014.pdf | ||
| Attachment F - API Internal Inspection Template.docx | DOCX document | |
| Attachment A - General Installation Security Requirements.docx | DOCX document | |
| Attachment E - API Internal Inspection Telecon Briefing Template.docx | DOCX document | |
| Solicitation_ERK_W9128F23Q0106.pdf | ||
| Attachment J.2 - Facility 123_External_18July2019.pdf | ||
| Attachment C - Tank Data Sheet.xlsx | XLSX spreadsheet | |
| Attachment D - Monthly Contractors Progress Management and Status Report.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
[COMPANY Letter Head]
DATE
Subject: RETURN TO SERVICE LETTER
STORAGE TANK NO. [ XXXXX]
Fuel System Inspection, [Location] Contract No. [XXXXX], Task Order [XX] Out-of-Service [API 653] Inspection
Tank [XXX] was inspected for serviceability evaluation in accordance with the requirements of [API STD 653, XX Edition, Date.]. The Inspection was performed by [Company Name] on [ddmmmyy].
The results of the inspection: The tank is in suitable condition for return to service. There are no mandatory repairs that require immediate attention, in order to prevent imminent risk to system operators, equipment integrity, or the adjacent environment.
The Tank was returned to service on [date].
RECOMMENDED FUTURE INSPECTION DATES no later than (NLT):
| API 653 Out-Of-Service tank inspection | [date] | ||
| API 653 In-Service tank inspection | [date] | ||
| …UT Roundness…Corrosion…etc | [date] |
SATE REGULATIONS (N/A if Not Applicable):
[State] Regulations follow [……] State Regulations for API 653 Out-Of-Service tank inspections is NLT [date]
Final documents will be included in the close out documentation as required by the task order.
Prepared by:
[Inspectors Name] [Title] [Company] API 653 Certified Inspector No. [XXXX]
Installation acknowledgement:
[Installation Point of Contact Name] [Title]
[USACE Fuels Project Manager] Fuels Project Manager