Attachment Exhibit A 654-22-003 Drawings.pdf

PDF 2 MB Posted

Attached to
Z1DB--Replace Dietetics and Cath Lab Flooring, Buildings 1 and 1D Reno, NV Project # 654-22-003 Reno, NV
Solicitation number
36C26126R0038
Issued by

About this file

This document is a set of contract documents for a federal construction project at the VA Sierra Nevada Healthcare System in Reno, Nevada. The project, identified as VA Project No. 654-22-003, involves the removal and replacement of existing flooring systems in the Dietetics Offices and Cardiac Cath Lab located in Buildings 1 and 1D at 975 Kirman Avenue. The total area of work encompasses 2,016 square feet, with 1,174 SF in the Dietetics area (Building 1) and 842 SF in the Cath Lab area (Building 1D).

The renovation specifies installation of new flooring materials including linear vinyl tile (LVT-1) in Dietetics offices and welded seam vinyl sheet flooring (WSF-1 and WSF-2) in the Cardiac Cath Lab, all supplied by Shaw Contract with specific color and size specifications. Wall bases will be replaced with rubber base (RB-1) in Dietetics and coved bases in the Cath Lab. The project requires contractors to remove and properly store existing equipment for reinstallation by VA staff after construction completion, patch damaged walls to match existing finishes, and comply with applicable standards including VA Design Manuals, 2018 International Building Code, NFPA codes, OSHA standards, and ASHRAE standards. Work is issued for bid at 100% contract document completion as of August 2, 2022. The project includes detailed specifications for material installation per manufacturer requirements, coordination drawings submission requirements at least 20 days prior to work commencement in each area, and comprehensive documentation of existing equipment locations and conditions prior to removal.

View the file

Other files

File Type Posted
36C26126R0038 0003.docx DOCX document
36C26126R0038 0002.docx DOCX document
RFI Responses Replace Cath Lab.docx DOCX document
36C26126R0038 0001.docx DOCX document
Site Visit Attendees List 05-20-2026.pdf PDF
Attachment Price Breakdown 654-22-003.xlsx XLSX spreadsheet
36C26126R0038_2.docx DOCX document
Attachment VAAR 852.219-75 JAN 2023 DEVIATION.pdf PDF
Attachment SOW 654-22-003.pdf PDF
Attachment Pre-solicitation Site Visit Presentation 654-22-003.pptx PPTX presentation
Attachment REQUEST FOR INFORMATION FORM 654-22-003.docx DOCX document
Attachment Wage Determination NV20260040 01-30-2026.pdf PDF
Attachment 654-22-003 Specifications.pdf PDF
Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

ELEVATOR

ELEVATOR

G O

V T

G O

V T

G O

V T

G O

V T

G O

V T

G O

V T

G O

V T

118.7023

0.0184

61.8518

STOP

STOP

S

ID

E

W A L K

RAMP

R A M P

BUMPER

BUMPER

AREA OF WORK

BLDG 10 BLDG 6

BLDG 1

BLDG 12

LOCUST STREET

PARKING LOT

BLDG 1A

TAYLOR

STREET

PARKING LOT

L O

C U

S T

S

T R

E E

T

K

I

R M

A N

V E

B U R N S S T R E E T

E A S T T A Y L O R S T R E E T

BLDG 10

BLDG 1D

BLDG 5

BLDG 4

AREA OF WORK

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE OR, DIETETICS &

CATH LAB FLOORING

SO/AA

GI-000

COVER SHEET

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

PROJECT

SITE

REMOVAL AND REPLACEMENT OF EXISTING FLOORING SYSTEMS IN THE

DIETETICS OFFICES AND CARDIAC CATH LAB.

PROJECT DESCRIPTION

VICINITY MAP

DEDUCT ALTERNATES

N/A

PROJECT TEAM

FACILITY

Department of Veterans Affairs VA Sierra Nevada Healthcare System Engineering Services 975 Kirman Avenue Reno, NV 89502

ARCHITECT

MA|Architects, Inc.

385 Van Ness Ave., Suite 110 Torrance, CA 90501

Contact: Sofie O'Brien P: 424.302.5271 E: s.obrien@ma-architects.net

PROJECT DATA

PROJECT ADDRESS:

BUILDING 1

CONSTRUCTION TYPE:

STORIES:

BLDG. OCCUPANCY:

AREA OF WORK: 1,174 SF

BUILDING 1D

CONSTRUCTION TYPE:

STORIES:

BLDG. OCCUPANCY:

AREA OF WORK: 842 SF

975 KIRMAN AVENUE

RENO, NV 89502

II (SPRINKLERED)

HEALTHCARE

DIETETICS

II (SPRINKLERED)

HEALTHCARE

CATH LAB

TOTAL AREA OF WORK: 2,016 SF

DEPARTMENT OF VETERANS AFFAIRS

VA Sierra Nevada Healthcare System

975 Kirman Avenue, Reno, NV 89502

VA Project No. 654-22-003

REPLACE DIETETICS & CATH LAB FLOORING

1" = 40'-0"

Reference Site Plan

Rev. Date Description

08.02.2022 100% Issue for Bid

ARCHITECTURAL

AD-202

AE-202

AE-900

2nd FLOOR DEMO / EQUIPMENT LIST (DIETETICS & CATH LAB) 2nd FLOOR RENOVATION PLAN (DIETETICS & CATH LAB)

ROOM FINISH SCHEDULE & DETAILS

GENERAL

GI-000

GI-001

GI-002

GI-003

GI-102

COVER SHEET

GENERAL NOTES AND STANDARDS

ABBREVIATIONS & SYMBOLS

OVERALL REFERENCE PLANS

2nd FLOOR PHOTO REFERENCE PLAN

SHEET INDEX

APPLICABLE STANDARDS:

VA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).

VA PG 18-10 Architectural Design Manual (Aug. 1, 2014)

VA PG 18-10 Electrical Design Manual (Dec. 1, 2019)

2018 International Building Code (IBC) (Only when specifically referenced in VA Design Documents, see notes below)

2018 NFPA 101 Life Safety Code

2019 NFPA 241 Standard for Safeguarding Construction, Alteration, and Demolition Operations

2018 NFPA National Fire Codes with the exception of NFPA 5000 and NFPA 900

2020 NFPA 780 Standards for Installation of Lighting Protection Systems

Occupational, Safety and Health Administration (OSHA) Standards

2019 VA Seismic Design Requirements, H-18-8

2017 National Electrical Code (NEC) (NFPA 70)

2018 International Plumbing Code (IPC)

2019 Safety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.

2017 ASME Boiler and Pressure Vessel Code

2019 National Roofing Contractors Associations (NRCA) Roofing Manual: Membrane Roof Systems

ASME Code for Pressure Piping

2015 Architectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)

Building Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)

Manual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)

Energy policy Act of 2005 (EPAct)

DOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High- Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.

Federal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)

Executive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.

Executive Order 13514: Federal Leadership in Environmental, Energy, and Economic Performance (Oct. 5, 2009)

The Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01 00 00 of the VA Master Construction Specification.

Ventilation for Acceptable Indoor Air Quality - ASHRAE Standard 62.1 - 2016.

Safety Standard for Refrigeration Systems - ASHRAE Standard 15 - 2016.

Energy Standard for Buildings Except Low Rise Residential Buildings - ASHRAE 90.1 - 2016

GENERAL NOTES:

1. THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS LISTED BY

THE "INDEX OF DRAWINGS".

2. FOR GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS APPLICABLE ONLY TO THE

DRAWINGS OF ONE DISCIPLINE, REFER TO THE DRAWINGS OF THAT DISCIPLINE - SEE

"INDEX OF DRAWINGS".

3. APPLICABLE PORTIONS OF THE CODES, REGULATIONS, AND STANDARDS LISTED HERE ARE

INCORPORATED BY REFERENCE INTO THE REQUIREMENTS OF THIS CONTRACT AND

ESTABLISH MINIMUM REQUIREMENTS WITH WHICH THE WORK MUST COMPLY.

THIS PROJECT AND ALL PARTS OF THE WORK ASSOCIATED WITH THE PROJECT -

INCLUDING MATERIALS, METHODS, ASSEMBLIES, ETC - SHALL COMPLY WITH ALL

APPLICABLE GOVERNING RULES, CODES, REGULATIONS, ORDINANCES, AND LAWS OF ALL

FEDERAL, STATE, DISTRICT, TERRITORIAL, AND LOCAL GOVERNMENT AUTHORITIES HAVING

JURISDICTION OVER THE DESIGN, CONSTRUCTION, AND OCCUPANCY OF THE PROJECT,

WHETHER LISTED BY THE CONTRACT DOCUMENTS OR NOT. NO PART OF THE CONTRACT

DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY TO AN

APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE, OR LAW.

NO PART OF THE CONTRACT DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT

WORK CONTRARY TO AN APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE,

OR LAW.

4. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT

ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.

5. ANY WORK INSTALLED IN CONFLICT WITH THE CONTRACT DRAWINGS, CODE

REQUIREMENTS OR MANUFACTURER REQUIREMENTS WITHOUT THE PRIOR APPROVAL OF

THE GOVERNMENT AND THE ARCHITECT SHALL BE CORRECTED AT THE CONTRACTOR'S

EXPENSE. THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK REJECTED BY THE

GOVERNMENT AS DEFECTIVE OR AS FAILING TO CONFORM TO THE CONTRACT

DOCUMENTS WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND

WHETHER OR NOT FABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL

BEAR ALL COSTS OF CORRECTING SUCH REJECTED WORK, NOT TO BE REIMBURSED.

6. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS WHICH,

WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF DRAWINGS. THE

SET OF DRAWINGS, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE "INDEX

OF DRAWINGS". PARTIAL SETS OF DRAWINGS ARE INCOMPLETE.

THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY

THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURE

INSTALLATION REQUIREMENTS. SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH

OTHER, BIDS SHALL BE BASED ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND

QUANTITY OF WORK INDICATED. ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL

BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.

7. THE ARCHITECTURAL FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND

ELEVATIONS ILLUSTRATE THE DESIGN INTENT. THE ARCHITECTURAL DRAWINGS

ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND LOCATION OF MANY, BUT

NOT ALL, EXPOSED ELEMENTS OF THE WORK. THE STRUCTURAL, MECHANICAL,

ELECTRICAL, PLUMBING, OTHER DRAWINGS, AND JOB SPECIFICATIONS ARE

SUPPLEMENTARY TO ARCHITECTURAL WORKING DRAWINGS. THE WORK DESCRIBED BY

THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON

DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURER INSTALLATION REQUIREMENTS.

SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH OTHER, BIDS SHALL BE BASED

ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND QUANTITY OF WORK INDICATED.

ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL BE IMMEDIATELY BROUGHT TO

THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.

8. THE SPECIFICATIONS ARE INTENDED TO COMMUNICATE THE DETAILED PROPERTIES AND

QUALITY OF THE INDIVIDUAL MATERIALS, ASSEMBLIES, AND SYSTEMS THAT COMPRISE THE

WORK; THE FUNCTIONAL AND PERFORMANCE REQUIREMENTS FOR THE INDIVIDUAL PARTS

OF THE WORK; AND THE FABRICATION AND INSTALLATION REQUIREMENTS FOR INDIVIDUAL

PARTS OF THE WORK - THE SPECIFICATIONS TAKE PRECEDENCE OVER THE DRAWINGS

WITH RESPECT TO INFORMATION OF THIS NATURE.

9. PROPRIETARY PRODUCTS OR ASSEMBLIES UTILIZED AS "BASIS OF DESIGN":

• ON OCCASION, THE DRAWINGS MAY REFER TO A SINGLE PROPRIETARY PRODUCT

OR ASSEMBLY WHILE THE SPECIFICATIONS LIST TWO OR MORE ACCEPTABLE

MANUFACTURES AND/OR PRODUCTS, WHEN THIS OCCURS, THE PRODUCT OR

ASSEMBLY ILLUSTRATED BY THE DRAWINGS IS THE "BASIS OF DESIGN" PRODUCT OR

ASSEMBLY.

• THE DIMENSIONS, MOUNTING HEIGHTS, CLEARANCES, AND ACCESS REQUIREMENTS

OF SPECIFIED PRODUCTS AND ASSEMBLIES OTHER THAN THE "BASIS OF DESIGN"

MAY VARY FROM THAT SHOWN BY THE DRAWINGS.

• THE CONTRACTOR MAY UTILIZE ANY OTHER SPECIFIED PRODUCT OR ASSEMBLY IN

LIEU OF THE "BASIS OF DESIGN" PRODUCT OR ASSEMBLY, AS APPROVED BY

GOVERNMENT’S REPRESENTATIVE. HOWEVER, THE CONTRACTOR IS RESPONSIBLE

(AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT) FOR ALL COORDINATION AND

REVISIONS TO DIMENSIONS AND/OR DETAILS NECESSARY TO ACHIEVE THE SAME

FUNCTIONAL AND AESTHETIC DESIGN INTENT AS ILLUSTRATED BY THE "BASIS OF

DESIGN" SHOWN BY THE CONTRACT DOCUMENTS.

10. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR

EXAMINING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS

BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IT IS NOT INTENDED

THAT THE CONTRACT DOCUMENTS INCLUDE EACH & EVERY SUB-SYSTEM AND/OR SUB-

COMPONENT NECESSARY TO FULLY AND PROPERLY COMPLETE THE WORK. SUB-SYSTEMS,

SUB-COMPONENTS OR DETAILS REQUIRED OR NORMALLY INCLUDED AS TRADE PRACTICE

MAY NOT BE SPECIFICALLY MENTIONED NOR SHOWN.

THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE

ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION OR RELATED WORK.

11. ALL WORK NOTED "N.I.C." OR "NOT IN CONTRACT" IS TO BE ACCOMPLISHED BY A

CONTRACTOR OTHER THAN THE GENERAL CONTRACTOR AND IS NOT TO BE PART OF THE

CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE TO

COORDINATE WITH ALL "OTHER" CONTRACTORS PER REQUIREMENTS ESTABLISHED BY

GOVERNMENT, WHICH ARE UNDER SEPARATE CONTRACT WITH THE GOVERNMENT.

12. THE ARCHITECT / ENGINEERS SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT

BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE ON

PROCEDURE, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE

WORK, ALL OF WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL

CONTRACTOR.

13. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF

ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH ALL REQUIREMENTS OF THE

CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT

ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE

REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK

OF THAT PARTY.

CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES

NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,

DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED

IN THE CONTRACT DOCUMENTS.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING OR PATCHING THAT

MAY BE REQUIRED TO COMPLETE WORK OR TO MAKE ITS SEVERAL PARTS FIT TOGETHER.

GENERAL NOTES CONTINUED:

13. THE THE CONTRACTOR SHALL, IN ADVANCE OF THE WORK, PREPARE COORDINATION

DRAWINGS SHOWING THE LOCATION OF OPENINGS THROUGH SLABS, THE PIPE SLEEVES

AND HANGER INSERTS, AS WELL AS THE LOCATION AND ELEVATION OF UTILITY LINES,

INCLUDING, BUT NOT LIMITED TO, CONVEYOR SYSTEMS, PNEUMATIC TUBES, DUCTS, AND

CONDUITS AND PIPES TWO INCHES AND LARGER IN DIAMETER. THESE DRAWINGS,

INCLUDING PLANS, ELEVATIONS, AND SECTIONS AS APPROPRIATE, SHALL CLEARLY SHOW

THE MANNER IN WHICH THE UTILITIES FIT INTO THE AVAILABLE SPACE AND RELATE TO

EACH OTHER AND TO EXISTING BUILDING ELEMENTS. DRAWINGS SHALL BE OF

APPROPRIATE SCALE TO SATISFY THE PREVIOUSLY STATED PURPOSES, BUT NOT

SMALLER THAN 3/8-INCH SCALE. DRAWINGS MAY BE COMPOSITE (WITH DISTINCTIVE

COLORS FOR THE VARIOUS TRADES) OR MAY BE SEPARATE BUT FULLY COORDINATED

DRAWINGS (SUCH AS SEPIAS OR PHOTOGRAPHIC PAPER REPRODUCIBLE) OF THE SAME

SCALE. SEPARATE DRAWINGS SHALL DEPICT IDENTICAL BUILDING AREAS OR SECTIONS

AND SHALL BE CAPABLE OF BEING OVERLAID IN ANY COMBINATION. THE SUBMITTED

DRAWINGS FOR A GIVEN AREA OF THE PROJECT SHALL SHOW THE WORK OF ALL TRADES

THAT WILL BE INVOLVED IN THAT PARTICULAR AREA. COMPLETE COMPOSITE DRAWINGS

OR SIX COMPLETE SETS OF SEPARATE REPRODUCIBLE DRAWINGS SHALL BE RECEIVED BY

THE GOVERNMENT NOT LESS THAN 20 DAYS PRIOR TO THE SCHEDULED START OF THE

WORK IN THE AREA ILLUSTRATED BY THE DRAWINGS, FOR THE PURPOSE OF SHOWING

THE CONTRACTOR’S PLANNED METHODS OF INSTALLATION. THE OBJECTIVES OF SUCH

DRAWINGS ARE TO PROMOTE CAREFULLY PLANNED WORK SEQUENCE AND PROPER

TRADE COORDINATION, IN ORDER TO ASSURE THE EXPEDITIOUS SOLUTIONS OF

PROBLEMS AND THE INSTALLATION OF LINES AND EQUIPMENT AS CONTEMPLATED BY THE

CONTRACT DOCUMENTS WHILE AVOIDING OR MINIMIZING ADDITIONAL COSTS TO THE

CONTRACTOR AND TO THE GOVERNMENT. IN THE EVENT THE CONTRACTOR, IN

COORDINATING THE VARIOUS INSTALLATIONS AND IN PLANNING THE METHOD OF

INSTALLATION, FINDS A CONFLICT IN LOCATION OR ELEVATION OF ANY OF THE UTILITIES

WITH THEMSELVES, WITH STRUCTURAL ITEMS OR WITH OTHER CONSTRUCTION ITEMS,

HE/SHE SHALL BRING THIS CONFLICT TO THE ATTENTION OF THE CONTRACTING OFFICER

IMMEDIATELY. IN DOING SO, THE CONTRACTOR SHALL EXPLAIN THE PROPOSED METHOD

OF SOLVING THE PROBLEM OR SHALL REQUEST INSTRUCTIONS AS TO HOW TO PROCEED

IF ADJUSTMENTS BEYOND THOSE OF USUAL TRADES’ COORDINATION ARE NECESSARY.

UTILITIES INSTALLATION WORK WILL NOT PROCEED IN ANY AREA PRIOR TO THE

SUBMISSION AND COMPLETION OF THE GOVERNMENT REVIEW OF THE COORDINATED

DRAWINGS FOR THAT AREA, NOR IN ANY AREA IN WHICH CONFLICTS ARE DISCLOSED BY

THE COORDINATION DRAWINGS, UNTIL THE CONFLICTS HAVE BEEN CORRECTED TO THE

SATISFACTION OF THE CONTRACTING OFFICER. IT IS THE RESPONSIBILITY OF THE

CONTRACTOR TO SUBMIT THE REQUIRED DRAWINGS IN A TIMELY MANNER CONSISTENT

WITH THE REQUIREMENTS TO COMPLETE THE WORK COVERED BY THIS CONTRACT WITHIN

THE PRESCRIBED CONTRACT TIME.

14. CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES

NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,

DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED

IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL

CUTTING, FITTING OR PATCHING THAT MAY BE REQUIRED TO COMPLETE WORK OR TO

MAKE ITS SEVERAL PARTS FIT TOGETHER. THE GENERAL CONTRACTOR IS RESPONSIBLE

TO REVIEW AND COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND

SUPPLIERS WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS.

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE DIETETICS &

CATH LAB FLOORING

SO/AA

GI-001

GENERAL NOTES AND STANDARDS

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

PROJECT GENERAL NOTES

APPLICABLE STANDARDS

Rev. Date Description

08.02.2022 100% Issue for Bid

ABC

AGGREGATE BASE COURSE

BB

B

BULLETIN BOARD

BD BOARD

BD FT

BHMA

BOARD FEET (FOOT)

BUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATION

BI FLD DR BIFOLDING DOORS

BEV BEVEL

BITUM BITUMINOUS

BKG BACKING

BLD BUILD

CAB

C

CABINET

CB CATCH BASIN

CCT

CG

CUBICLE CURTAIN TRACK

CORNER GUARD

CEM

CER

CEMENT, CEMENTITIOUS

CERAMIC

CCTV CLOSED CIRCUIT TELEVISION

CH BD CHALKBOARD

CI CAST IRON

CJ CONTROL JOINT

CL

CLG

CLR

CMU

CNTR

COL

CONC

CONF

CONN

CONSTR

CONT

CONTR

CORR

CPT

CSK

CSP

CSWK

CU

CW

CENTER LINE

CEILING

CLEAR

CONCRETE MASONRY UNIT

COUNTER

COLUMN

CONCRETE

CONFERENCE

CONNECTION

CONSTRUCTION

CONTINUOUS

CONTRACTOR

CORRUGATED

CARPET

COUNTERSUNK

COMBINATION STANDPIPE

CASEWORK

CUBIC

COLD WATER

D

D

DEPTH

DBL DOUBLE

DBL ACT DOUBLE ACTING

DEG DEGREE

DEMO DEMOLISH

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIFF DIFFUSER

DIM DIMENSION

DIM PT DIMENSION POINT

DISP DISPENSER

DIST DISTANCE

DN DOWN

DR DRAIN

DS DOWNSPOUT

DSP DRY STANDPIPE

DT DRAPERY TRACK

DWG DRAWING

DWGS DRAWINGS

(E)

E

EXISTING

EA EACH

EDR EQUIPMENT DRAWING

EG EDGE GUARD

EIFS EXTERIOR INSULATION FINISH SYSTEM

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRICAL

ELEV ELEVATOR

EMER EMERGENCY

ENCL ENCLOSURE

ENGR ENGINEER

EOS EDGE OF SLAB

EP ELECTRICAL PANEL

EPB ELECTRICAL PANEL BOARD

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ESCAL ESCALATOR

EST ESTIMATE(D)

EWC ELECTRIC WATER COOLER

EXC EXCAVATED

EXH EXHAUST

EXP EXPANSION

EXP JT EXPANSION JOINT

FURN FURNITURE

FXTR FIXTURE

G

G

GAS

H

H

HIGH

GA GAUGE, GAGE

GAL GALLON

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GFRC GLASS FIBER REINFORCED CONCRETE

GFRG GLASS FIBER REINFORCED GYPSUM

GFRP GLASS FIBER REINFORCED PLASTIC

GLU LAM GLUE LAMINATED

GLZ GLAZING

GR GRADE OR GRADING

GVL GRAVEL

GYP GYPSUM

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

ID

I

INSIDE DIAMETER

JAN

J

JANITOR

KG

K

KILOGRAM

L

L

LENGTH, LONG

M

(N) N

NA

NAAMM

NAT

NATL

NC

NCOMBL

NEC

NEG

NEMA

NEUT

NFC

NFPA

NIC

NO

NOM

NR

NRC

NRCA

NRP

NS

NUM

N

NEW

NORTH

NOT APPLICABLE

NATIONAL ASSOCIATION OF

ARCHITECTURAL METAL MANUFACTURERS

NATURAL

NATIONAL

NOISE CRITERIA

NONCOMBUSTIBLE

NATIONAL ELECTRICAL CODE

NEGATIVE

NATIONAL ELECTRICAL MANUFACTURERS

ASSOCIATION

NEUTRAL

NATIONAL FIRE CODE

NATIONAL FIRE PROTECTION

ASSOCIATION

NOT IN CONTRACT

NUMBER

NOMINAL

NOISE REDUCTION

NOISE REDUCTION COEFFICIENT

NATIONAL ROOFING CONTRACTORS

ASSOCIATION

NONREMOVABLE

NARROW STILE

NUM NUMERAL

P

QA

QC

QRY

QT

QTB

QTF

QTR

QTY

QUAD

QUAL

Q

QUALITY ASSURANCE

QUALITY CONTROL

QUARRY

QUARRY TILE

QUARRY TILE BASE

QUARRY TILE FLOOR

QUARTER

QUANTITY

QUADRANT

QUALITY

R

R

RISER

S

SA

SALV

SAMP

SAN

SAT

SATC

SB

SBS

SBSTR

SC

SCH

SCHED

SCHEM

SCP

SCRN

SCT

SCWD

SD

SDG

SECT

SEG

SEL

SEP

SF

SFTWD

SGD

SGL

SHR

SHR HD

SHRH

SHT

SHT MTL

SHTHG

SHV

SIM

SJ

SJI

SK

SKLT

SLD WDW

SLDG

SLNT

SM

SMK

SND

SND INS

SNDU

SPEC

SPKLR

SPKR

SPLY

SQ

SQ IN

SQ YD

SS

SST

ST

STC

STD

STIF

STL JST

STL LNTL

STL PL

STL RF DK

STL TB

STL TR

STNLS

STOR

STR

STRUCT

SUB

SURF

SUSP

SUSP CLG

SV

SW

SWDR

SYM

SYNTH

SYS

SOUTH

SUPPLY AIR

SALVAGE

SAMPLE

SANITARY

SUSPENDED ACOUSTICAL TILE

SUSPENDED ACOUSTICAL TILE CEILING

SPLASH BLOCK

STYRENE BUTADIEN STYRENE

SUBSTRATE

SHADING COEFFICIENT OR SOLID CORE

SCHOOL

SCHEDULE

SCHEMATIC

SCUPPER

SCREEN

STRUCTURAL CLAY TILE

SOLID CORE WOOD DOOR

SHOP DRAWINGS, SMOKE DETECTOR,

OR SOAP DISPENSER

SIDING

SECTION

SEGMENT

SELECT

SEPARATE

SQUARE FOOT (FEET)

SOFTWOOD

SLIDING GLASS DOOR

SINGLE

SHOWER

SHOWER HEAD

SHOWER DRAIN

SHEET

SHEET METAL

SHEATHING

SHELVING

SIMILAR

SCORED JOINT

STEEL JOIST INSTITUTE

SKETCH

SKYLIGHT

HORIZONTAL SLIDING WINDOW

SLIDING

SEALANT

SHEET METAL

SMOKE

SANITARY NAPKIN DISPENSER

SOUND INSULATION

SANITARY NAPKIN DISPOSAL UNIT

SPECIFICATION

SPRINKLER

SPEAKER

SUPPLY

SQUARE

SQUARE INCH

SQUARE YARD

SANITARY SEWER OR SERVICE SINK

STAINLESS STEEL

STAIRS OR STREET

SOUND TRANSMISSION CLASS

STANDARD

STIFFENER

STEEL JOIST

STEEL LINTEL

STEEL PLATE

STEEL ROOF DECK

STEEL TUBE

STEEL TRUSS

STAINLESS

STORAGE

STRINGERS

STRUCTURAL

SUBSTITUTE

SURFACE

SUSPEND

SUSPENDED CEILING

SHEET VINYL

SWITCH

SWING DOOR

SYMBOL

SYNTHETIC

SYSTEM

T T&G T&M

TB

TCA

TCP

TD

TECH

TEL

TEMP

TER

THD

THERM

THK

THRES

THRU

THRUOUT

TK BD

TMPD

TMPD GL

TN

TO

TO FDN

TOB

TOM

TOP

TOS

TOW

TPD

TPH

TR

TRANS

TRANS WD FIN

TRTD

TS

TSTAT

TV

TYP

T

TREAD

TONGUE AND GROOVE

TIME AND MATERIALS

THROUGH BOLT OR TOWEL BAR

TILE COUNCIL OF AMERICA

TELEPHONE CONTROL PANEL TEMPERATURE

TRAFFIC CONTROL PLAN

TOWEL DISPENSER

TECHNICAL

TELEPHONE

TEMPERATURE OR TEMPORARY

TERRAZZO

THREAD

THERMAL

THICKNESS

THRESHOLD

THROUGH

THROUGHOUT

TACKBOARD

TEMPERED

TEMPERED GLASS

TRUE NORTH

TOP OF

TOP OF FOUNDATION

TOP OF BEAM

TOP OF MANSORY

TOP OF PARAPET

TOP OF STEEL

TOP OF WALL

TOILET PAPER DISPENSER

TOILET PAPER HOLDER

TOWEL BACK

TRANSOM

TRANSPARENT WOOD FINISH

TREATED

TENSILE STRENGHTH OR TUBE STEEL

THERMOSTAT

TELEVISION

TYPICAL

W

W

WEST

XFMR

X BRACE

XPS

X

TRANSFORMER

CROSS BRACE

EXTRUDED POLYSTYRENE BOARD

(INSULATION)

YD

YR

Y

YARD

YEARHB HOSE BIBB

HC HOLLOW CORE

HD HEAD

HDBD HARDBOARD

HDW HARDWARE

HDWD HARDWOOD

HGT HEIGHT

HM HOLLOW METAL

HNDRL HANDRAIL

HORIZ HORIZONTAL

HPT HIGH POINT

HR HOUR

HVAC HEATING-VENTILATION-AIR CONDITIONING

IN INCH

INCAND INCANDESCENT

INCL INCLUDE, INCLUDING

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INV INVERT

IVT INTRAVENOUS TRACK

JST JOIST

JT JOINT

KIT KITCHEN

KPL KICK PLATE

KS KNEE SPACE

LAB LABORATORY

LAD LADDER

LAM LAMINATE

LAM GL LAMINATED GLASS

LAU LAUNDRY

LAV LAVATORY

LBR LUMBER

LBS POUND

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LH LEFT HAND

LHR LEFT HAND REVERSE

LIB LIBRARY

S

MACH

MACH RM

MAINT

MAN

MATL

MATV

MAX

MB

MCB

MD

ME

MEAS

MECH

MECH RM

MED

MED

MEK

MEL

MEMB

MEMO

MEZZ

MF

MFD

MFG

MFR

MFR REC

MGT

MH

MIC

MID

MIL STD

MIN

MIRR

MISC

MIT

MKR

ML

MLDG

MLWK

mm

PAR

PARA

PART

PAT

PA

PB

PBD

PC

PCA

PCC

PCCP

PCD

PCF

PCP

PED

PEN

PEND

PERF

PERM

PERIM

PERP

PGBD

PHAR

PHOTO

PHS

PKG

PI

PL

PL GL

PLAM

PLAS

PLBG

PLYWD

PMTL

PNEU

PNL

PO

PO

POLY

PR

PRCST

PREFAB

PREFIN

PRELIM

PREP

PRESS

PREV

PRKG

PRMLD

PROJ

PROP

PSF

PSI

PT

PTD

PTN

PVC

PVG

PWR

PARALLEL OR PARAPET

PARAGRAPH

PARTIAL

PATTERN

PUBLIC ADDRESS

PUSHBUTTON

PARTICLEBOARD

PIECE, POLYCARBONATE OR PORTLAND

CEMENT

PORTLAND CEMENT ASSOCIATION

PRECAST CONCRETE

CONCRETE PAVEMENT

PAPER CUP DISPENSER

POUNDS PER CUBIC FOOT

PORTLAND CEMENT PLASTER

PEDESTAL

PENETRATE

PENDANT

PERFORATED

PERMANENT

PERIMETER

PERPENDICULAR

PEGBOARD

PHARMACY

PHOTOGRAPH

PHILLIPS HEAD SCREW

PACKAGE

POINT OF INTERSECTION

PROPERTY LINE

PLATE GLASS

PLASTIC LAMINATE

PLASTER OR PLASTIC

PLUMBING

PLYWOOD

PAINTED METAL

PNEUMATIC

PANEL

POST OFFICE PURCHASE ORDER

PURCHASE ORDER POST OFFICE

POLYETHYLENE (PLASTIC)

PAIR

PRECAST

PREFABRICATE

PREFINISH

PRELIMINARY

PREPARATION

PRESSURE

PREVIOUS

PARKING

PREMOLDED

PROJECT

PROPERTY

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

PAINT, PNEUMATIC TUBE, OR

PRESSURE TREATED

PAPER TOWEL DISPENSER

PARTITION

POLYVINYL CHLORIDE (PLASTIC)

PAVING

POWER

RA RETURN AIR

RAD RADIUS

RB RESILIENT BASE

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

RD ROOF DRAIN

RECT RECTANGULAR

REF REFERENCE

REFR REFRIGERATOR

REG REGISTER

REINF REINFORCE (D) (ING) (MENT)

REQD REQUIRED

REQT REQUIREMENT

RESIL RESILIENT

RET RETURN

REV REVISION

RF RESILIENT FLOORING

RH RIGHT HAND

RHMS ROUND HEAD MACHINE SCREW

RHWS ROUND HEAD WOOD SCREW

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RWL RAIN WATER LEADER

UC

U

UNDER COUNTER

UL UNDERWRITERS LABORATORIES

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTABLE POWER SUPPLY

UTIL

UCD

UGND

ULT

UNFIN

UR

UV

UTILITY

UNDERCUT DOOR

UNDERGROUND

UNTIMATE

UNFINISH

URINAL

ULTRAVIOLET

W/ WITH

W/O WITHOUT

WC WATER CLOSET OR WALL COVERING

WD WOOD

WDW WINDOW

WGL WIRE GLASS

WCHR WHEELCHAIR

WM WIRE MESH

WO WHERE OCCURS

WPT WORKING POINT

WR WATER RESISTANT

WSCT WAINSCOT

WSP WET STANDPIPE

WT WEIGHT

WTHPRF WEATHERPROOF

WTRPRF WATERPROOF

WWF WELDED WIRE FABRIC

WWM

WARR

WBL

WC WL HNG

WCL WL MTD

WF

WFAB

WFR

WFS

WH

WHSE

WLD

WP

WPD

WPM

WS

WELDED WIRE MESH

WARRANTY

WOOD BLOCKING

WATER CLOSET, WALL HUNG

WATER COOLER, WALL HUNG

WIDE FLANCE

WALL FABRIC

WOOD FRAME

WOOD FURRING STRIPS

WATER HEATER

WAREHOUSE

WELDED

WATERPROOFING

WATER PRESSURE DROP

WATERPROOF MEMBRANE

WEATHERSTRIP

CCR CARD CONTROL READER

BLDG BUILDING

CT CERAMIC TILE

F

F/F FACE TO FACE

FA FIRE ALARM

FAS FIRE ALARM STATION OR FASCIA

FB FLAT BAR

FCU FAN COIL UNIT

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDN FOUNDATION

FEC FIRE EXTINGUISHER CABINET

FE FIRE EXTINGUISHER

FF FINISH FACE

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHWS FLAT HEAD WOOD SCREW

FHY FIRE HYDRANT

FLAM FLAMMABLE

FLASH FLASHING

FLEX FLEXIBLE

FLUOR FLUORESCENT

FO FACE OF OR FINISHED OPENING

FSB FOLDING SHOWER BENCH

FSTNR FASTENER

FT FOOT, FEET

O/O O

OA

OC

OCC

OCT

OD

OD

OF/CI

OFD

OFF

OF/OI

OH

OH DR

OPH

OPNG

OPP

OPR

OPT

OR

ORD

ORG

ORIG

ORN

OSHA

OUT

OZ

OVHD

O

OUT TO OUT

OXYGEN

OUTSIDE AIR OR OVERALL

ON CENTER

OCCUPY

OCTAGON

OUTSIDE DIAMETER OUTSIDE

DIMENSION

OUTSIDE DIMENSION OUTSIDE

DIAMETER

OWNER FURNISHED/CONTRACTOR

INSTALLED

OVERFLOW DRAIN

OFFICE

OWNER FURNISHED/OWNER INSTALLED

OVERHANG

OVERHEAD (COILING) DOOR

OPPOSITE HAND

OPENING

OPPOSITE

OPERABLE

OPTIONAL

OPERATING ROOM OR OUTSIDE RADIUS

ORDNANCE OR OVERFLOW ROOF

DRAIN

ORGANIC

ORIGINAL

ORNAMENTAL

OCCUPATIONAL SAFETY AND HEALTH

ADMINSTRATION

OUTLET

OUNCE

OVERHEAD

VAC

V

VACUUM

VB VALVE BOX

VCT VINYL COMPOSITION TYLE

VERT VERTICAL

VEST VESTIBULE

VIT VITREOUS

VP VENT PIPE

VOL VOLUME

VWC VINYL WALL COVERING

ABBREVIATIONS SYMBOLS

ANGLE

@ AT

C CENTER LINEL

Ø DIAMETER

= EQUAL

> GREATER THAN

< LESS THAN

± PLUS OR MINUS (TOLERANCE)

# POUND(S)

' FOOT OR FEET

" INCH OR INCHES

FOF FACE OF FINISH

HSS HOLLOW STRUCTURAL STEEL

SYMBOLS LEGENDS

SHEET

NORTH IDENTIFIER

ELEVATION

IDENTIFIER

KEY NOTE TAG

GRID LINES

CALL-OUT IDENTIFIER

? PHOTOGRAPH

LOCATIONS

+? CEILING TAG

? WALL TYPE TAG

SHEET #

REF # ON SHEET

WINDOW TAG

DOOR TAG?

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT

AAMA

AIR CONDITIONING UNIT

AMERICAN ARCHITECTURAL

MANUFACTURERS ASSOCIATION

A/E ARCHITECT / ENGINEER

AB ANCHOR BOLT

AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE

ACI AMERICAN CONCRETE INSTITUTE

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACST ACOUSTIC

ACS PNL ACESS PANEL

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADC AUTOMATIC DOOR CLOSER

ADDL ADDITIONAL

ADH ADHESIVE

ADDN ADDITION

ADJ ADJACENT, ADJOINING, OR ADJUSTABLE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGC ASSOCIATED GENERAL CONTRACTORS

AGA AMERICAN GAS ASSOCIATION

AGGR AGGREGATE

AHJ AUTHORITY HAVING JURISDICTION

AHR ANCHOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF ARCHITECTS

ALT ALTERNATE

AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

AMP AMPERE

AMT AMOUNT

ANOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

ANT ANTENNA

APA AMERICAN PLYWOOD ASSOCIATION

APPD APPROVED

APPROX APPROXIMATE

APT APARTMENT

AR AS REQUIRED

ARCH ARCHITECT

ASB ASBESTOS

ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION

ASKLR AUTOMATIC SPRINKLER

ASPH ASPHALT

ASSN ASSOCIATION

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

ATCH ATTACHMENT

ATM AUTOMATIC TELLER MACHINE

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AVE AVENUE

AVG AVERAGE

AW ACID WASTE

AWI ARCHITECTURAL WOODWORKING INSTITUTE

AWPA AMERICAN WOOD PRESERVERS' ASSOCIATION

AWS AMERICAN WELDING SOCIETY

AWT ACOUSTICAL WALL TREATMENT

BLKT BLANKET

BLVD BOULEVARD

BM

BR

BEAM OF BENCHMARK

BEDROOM

BRCG

BRDG

BRACING

BRIDGING

BOT BOTTOM

BRDG JST BRIDGING JOIST

BRG BEARING

BRG PL BEARING PLATE

BRKT BRACKET

BRZ BRONZE

BSMT BASEMENT

BTWN BETWEEN

BU BUSHEL

BUR BUILT–UP ROOFING

C CELCIUS CHANNEL

C CONC CAST CONCRETE

C TO C

CBB

CENTER TO CENTER

CEMENTITIOUS (BACKER) BOARD

CC

CCW

CUBIC CENTIMETER

COUNTERCLOCKWISE

CAC CEILING ATTENUATION CLASS

CD CONSTRUCTION DOCUMENTS OR CONTRACT

DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI

CF/OI

CONTRACTOR FURNISHED/CONTRACTOR

INSTALLED

CONTRACTOR FURNISHED/CONTRACTOR

INSTALLED

C LABEL CLASS C DOOR

CFLG

CFM

COUNTERFLASHING

CUBIC FEET PER MINUTE

CFS CUBIC FEET PER SECOND

CG CENTER OF GRAVITY OR CORNER GUARD

CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS

CHEM

CHFR

CHK

CI

CIP

CIR

CIRC

CNR

CNTR

CO

CONC FLR

COND

CONF

CORR

CMP

CRS

CRSI

CHEMICAL

CHAMFER

CHECK

CAST IRON

CAST–IN–PLACE

CIRLCE

CIRCULAR

CORNER

COUNTER

CARBON MONOXIDE, CERTIFICATE OF

OCCUPANCY, CLEANOUT, OR COMPANY

CONCRETE FLOOR

CONDENSER OR CONDITION

CONFERENCE

CORRIDOR

CRITICAL PATH METHOD

COLD ROLLED STEEL

CONCRETE REINFORCING STEEL INSTITUTE

CPRS COMPRESSIBLE

CSB CONCRETE SPLASH BLOCK

CSG CASING

CSK

CSWK

COUNTER SUNK

CASEWORK

CTB

CTF

CERAMIC TILE BASE

CERAMIC TILE FLOOR

CSMT CASEMENT

CTG

CSI CONSTRUCTION SPECIFICATIONS INSTITUTE

COATING

CTRL CONTROL

CU FT

CU IN

CUBIC FEET

CUBIC INCH

CTR CENTER CONTOUR

CU YD CUBIC YARD

CURT

CYL

CURTAIN

CYLINDER

CYL L CYLINDER LOCK

D LABEL CLASS D DOOR

DAT DATUM

DB DECIBEL

DBL GLZ DOUBLE GLAZE

DC DIRECT CURRENT

DEL DELETE

DIR DIRECTION

DIV DIVIDE OR DIVISION

DL DEAD LOAD

DOC DOCUMENT

DOUG FIR DOUGLAS FIR

DOZ DOZEN

DR CL DOOR CLOSER

DR FR DOOR FRAME

DR OPNG DOOR OPENING

DSGN DESIGN

DW DISHWASHER

DWTR DUMBWATER

E EAST

E LABEL CLASS E DOOR

EFF EFFICIENCY

EFS EXTERIOR FINISH SYSTEM

EJ EXPANSION JOINT

EMER SHR EMERGENCY SHOWER

ENCL ENCLOSURE

ENVIR ENVIRONMENT

EPA ENVIRONMENTAL PROTECTION AGENCY

EPO EMERGENCY POWER OFF

EPS EXPANDED POLYSTRYRENE BOARD

(INSULATION)

ERD EXISTING ROOF DRAIN

ESC ESCAPE OR ESCUTCHEON

ESMT EASEMENT

ESP ESPECIALLY

ETC ET CETERA

EW EACH WAY

EWS EYE WASH STATION

EXH EXHAUST

EXIST EXISTING

EXP BT EXPANSION BOLT

EXST GR EXISTING GRADE

EXT EXTERIOR, EXTERNAL, OR

EXTINGUISHER

EXT GR EXTERIOR GRADE

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

F FAHRENHEIT OR FEMALE

FAB FABRIC

FAC FACTOR

FACIL FACILITY

FAS BD FASCIA BOARD

FCO FLOOR CLEANOUT

FCTY FACTORY

FDTN FOUNDATION

FF EL FINISH FLOOR ELEVATION

FF&E FURNITURE, FIXTURE, AND EQUIPMENT

FH FLAT HEAD

FIG FIGURE

FIL FILLET

FIN FINISH

FHP FULL HEIGHT PARTITION

FLG FLOORING

FLR FLOOR

FIN WD FINISH WOOD

FIXT FIXTURE

FLDG FOLDING

FL FLOORLINE

FLUOR FIX FLUORESCENT FIXTURE

FM FACTORY MUTUAL

FLR FIN FLOOR FINISH

FLR SK FLOOR SINK

FRZ FREEZER

FM–G FACTORY MUTUAL GLOBAL

FOC FACE OF CONCRETE OR FACE OF CURB

FOF FACE OF FINISH

FOM FACE OF MANSORY

FOS FACE OF SLAB OR FACE OF STUD

FOUNT FOUNTAIN

FOW FACE OF WALL

FP FIRE PROTECTION OR FIREPROOF

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FIRE RATING, FIRE RESISTANT, OR FRAME

FREQ FREQUENCY

FRMG FRAMING

FRP FIBER REINFORCED POLYESTER OR

FIBERGLASS REINFORCED PLASTIC

FR SINK FLUSHING RIM SINK

FS FEDERAL SPECIFICATION

FURG FURRING

FWC FABRIC WALLCOVERING

FUT FUTURE

GD GUARD

GDR GUARD RAIL

GEN GENERAL OR GENERATOR

GL GLASS

GI GRAB BAR OR GALVANIZED IRON

GC GENERAL CONTRACTOR

GFRC GLASS FIBER REINFORCED CONCRETE

GFRG GLASS FIBER REINFORCED GYPSUM

GL GLASS

GL BLK GLASS BLOCK

GR FL GROUND FLOOR

GRAN GRANITE

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GSM GALVANIZED SHEET METAL

GSU GLAZED STRUCTURAL UNIT

GT GROUT

GUAR GUARANTEE

GUT GUTTER

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GSM GALVANIZED SHEET METAL

GSU GLAZED STRUCTURAL UNIT

H PLAM HIGH PRESSURE PLASTIC LAMINATE

HAZ MAT HAZARDOUS MATERIALS

HCWD HOLLOW CORE WOOD DOOR

HDNR HARDENER

HDO HIGH DENSITY OVERLAY

HDR HEADER

HEPA HIGH EFFICIENCY PARTICULATE AIR

(FILTER)

HEX HEXAGON

HF HIGH FREQUENCY

HGR HANGER

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND FRAME

HMF HOLLOW METAL FRAME

HO HOLD OPEN

HOSP HOSPITAL

HP HIGH PRESSURE OR HORSEPOWER

HQ HEADQUARTERS

HS HEAT-STRENGTHENED (GLASS) OR

HIGH STRENGTH

HSE HOUSE

HSKPG HOUSEKEEPING

HST HOIST

HT HEIGHT

HVY HEAVY

HW HOT WATER

HYD HYDRANT

HYDR HYDRAULIC

I INTERSTATE (HIGHWAY) OR MOMENT

OF INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID NO IDENTIFICATION NUMBER

ILLUM ILLUMINATION

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

IRMA INVERTED ROOF MEMBRANE ASSEMBLY

IWH INSTANTANEOUS WATER HEATER

J-BOX JUNCTION BOX

KD KILN DRIED

KO KNOCKOUT

LIN LINEAR

LINO LINOLEUM

LIQ LIQUID

LKR LOCKER

LKR RM LOCKER ROOM

LKWASH LOCKWASHER

LL LEAD LINED

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMST LIMESTONE

LNDSCP LANDSCAPE

LR LIVING ROOM

LRG LARGE

LRV LOUVERED ROOF VENT

LS LUMP SUM

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LTNG LIGHTNING

LVD LOUVERED

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

LWIC LIGHTWEIGHT INSULATING CONCRETE

LYR LAYER

MACHINE

MACHINE ROOM

MAINTENANCE

MANUAL

MATERIAL

MASTER ANTENNA TELEVISION SYSTEM

MAXIMUM

MACHINE BOLT

METAL CORNER BEAD

DECK

MECHANICAL ENGINEER

MEASURE

MECHANICAL

MECHANICAL ROOM

MEDICAL MEDIUM

MEDIUM MEDICAL

METHYL ETHYL KETONE

MELAMINE

MEMBRANE

MEMORANDUM

MEZZANINE

MILL FINISH

MANUFACTURED

MANUFACTURING

MANUFACTURER

MANUFACTURER'S RECOMMENDATION

MANAGEMENT

MANHOLE

MICROPHONE

MIDDLE

MILITARY STANDARD

MINIMUM MINUTE

MIRROR

MISCELLANEOUS

MITER

MARKER

METAL LATH

MOLDING (MOULDING)

MILLWORK

MILLIMETER

MO

MOD

MOD BIT

MON

MOPR

MR

MS

MTD

MTG

MTL

MULL

MW

MWP

MASONRY OPENING OR MOTOR

OPERATED

MODEL, MODIFY OR MODULE

MODIFIED BITUMEN

MONITOR

MOP RACK

MOISTURE RESISTANT

MACHINE SCREW OR MOP SINK

MOUNTED

MOUNTING

METAL

MULLION

MICROWAVE

MEMBRANE WATERPROOFING

RCVT

RLG

RS

RT

RV

RVS

RFI

RFP

RECEIVER

RAILING

ROUGH OPENING

RIGHT

ROOF VENT

REVERSE

REQUEST FOR INFORMATION

REQUEST FOR PROPOSAL

STUD WIDTH PARTITION WIDTHPARTITION TYPE DESIGNATION = 'X'

NON-RATED PARTITION = N

ACOUSTICAL RATED PARTITION = A

SHAFT PARTITION = S

FURRED PARTITION = F

REFER TO PARTITION DETAIL FOR COMPLETE LEGEND & FURTHER INFORMATION.

#X#

PARTITION

TYPE

STUD WIDTH

FIRE RATING

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE DIETETICS &

CATH LAB FLOORING

SO/KB

GI-002

ABBREVIATIONS & SYMBOLS

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

ABBREVIATIONS

EXPANSION JOINT

EXPANSION JOINT

NORTH

ACCESS PANEL

L A N D I N G

R A M P

L A N D I N G R A M P R A M P

L A N D I N G

ACCESS PANEL

ROOF-10

GUTTER &

DOWNSPOUT

ROOF BELOW

TUBULAR SKYLIGHTS

C2CD01

CS1D4

C2CD02

C2CD11

C2CD09

C2CD08

DS1D3

D2CD01

D2XD01

D2C202

D2CD04

D2CD03

C2XD01

CS2D2

C2CD06

C2CD07

CDC05

CS5D1

GS1D3

G2XD01

HS1D5

H2CD02

HS1D6

GS3D1

GS2D2

DS2D1

H2CD01

G2CD03

BS2D4

B2XD01

D2CD

B1XDO3

OPEN TO BELOW

E Q U

IP

SHELFSHELF

SHELF SHELF

SHELFSHELF

SHELFSHELF

SHELF

SHELF

SHELF

SHELF

SHELF

SHELF

SHELF

SHELF

SHELF SHELF

SHELFSHELF

SHELF SHELF

SHELFSHELF

S H E

LFSHELF

SHELFSHELF

SHELF SHELF SHELF

SHELF SHELF SHELF

LOCKERS

SHELF SHELF

SHELF

S H E

LF

SHELF SHELF

SHELF

SHELF

FDS

S H E

LF

S H E

LF

S H E

LF

SHELFSHELFSHELF

FEC

FEC

S H E

LF

S H E

LF

S H E

LF

FEC

FEC

FEC

FE

C

FEC

FEC

FEC FECFEC

F E C

F E C

FEC

UP

DN

DN

DN

DN

DN

DN

DN

UP UP

AE-202

AE-202

CATH LAB

DIETETICS

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE DIETETICS &

CATH LAB FLOORING

SO/AA

GI-003

OVERALL REFERENCE PLANS

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

Rev. Date Description

08.02.2022 100% Issue for Bid

1" = 30'-0"

2nd Floor Reference Plan

F E C

FEC

GI-102

GI-102

CATH

EQUIPMENT

CARDINAL HEALTH

FILE CABINET

OMNICELL

MEDICATION CABINETS

HELMER

MEDICATION REF

(UNDER WIRE RACK)

ROLLING

METAL TABLE

ROLLING METAL TABLES

GI-102

GI-102

GI-102

GI-102

REF

MICROWAVE

FILE

CABINET

STORAGE

CABINET

DRAWERS

COMPUTER

ON WHEELS

SHREDDER

COPIER

SHREDDER

FILE DRAWER

STORAGE

CABINET

COPIER

CONFERENCE

TABLE

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE DIETETICS &

CATH LAB FLOORING

SO/AA

GI-102

2nd FLOOR PHOTO REFERENCE PLAN

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

1/4" = 1'-0"

2nd Floor Cath Lab Photo Reference Plan 1/4" = 1'-0"

2nd Floor Dietetics Photo Reference Plan

G2559 - Cardiac Cath Lab

C2559B - Cardiac Cath Lab Support Spaces

C2331 - Office

C2332 - Office

C2335 - Staff Lounge (Used as Office)

C2337 - Office (Used as Staff Lounge)

C

FEC

174 SF

Chief Nutrition and Food Service

C2333

198 SF

Office C2331

261 SF

Staff Lounge (Used as Office) C2335

289 SF

Office (Used as Staff Lounge) C2337

75 SF

Office C2335A

65 SF

Electrical C2337-2

10 SF

Fire Closet C2331A

333 SF

Corridor C108

177 SF

Office C2332

1084 SF

Dishwashing Area

C2334

REF

MICROWAVE

FILE

CABINET

STORAGE

CABINET

DRAWERS

COMPUTER

ON WHEELS

SHREDDER

COPIER

SHREDDER

FILE DRAWER

STORAGE

CABINET

COPIER

CONFERENCE

TABLE

101 107

101 107

101 107

101 107

101 107

101 107

118 SF

Restroom Men

G2551

117 SF

Restroom Women

621 SF

Cardiac Cath Lab

G2559

221 SF

Cardiac Cath Support Spaces G2559B

154 SF

Cardiac Cath System

Component Room

G2559A

55 SF

Unisex Toilet G2539

114 SF

Cardiac Cath Patient

Consultation G2541

60 SF

EMG

Dressing G2543

704 SF

Corridor G2C09

86 SF

Electrical

ID171

28 SF

Tel

ID170

45 SF

Storage G2604

OMNICELL

MEDICATION CABINETS

ROLLING

METAL TABLE

ROLLING METAL TABLES

101 109

101 110

114 114

2nd FLOOR - DIETETICS

2nd FLOOR - CATH LAB

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE DIETETICS &

CATH LAB FLOORING

SO/AA

AD-202

2nd FLOOR DEMO / EQUIPMENT LIST

(DIETETICS & CATH LAB)

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

1/4" = 1'-0"

2nd Floor - Dietetics FFE Plan 1/4" = 1'-0"

2nd Floor - Cath Lab FFE Plan

Rev. Date Description

08.02.2022 100% Issue for Bid

Key Notes

101 GENERAL NOTE: REMOVE ALL EXISTING FLOORING &

ASSOCIATED WALL BASE IN AREA NOTED.

105 EXISTING EQUIPMENT TO BE DISCONNECTED FROM

UTILITIES, REMOVED & STORED FOR REINSTALLATION.

106 EXISTING CATH IMAGING EQUIPMENT TO REMAIN;

PROTECT IN PLACE.

107 EXISTING FURNISHINGS TO BE REMOVED BY VA.

109 EXISTING EQUIPMENT/CARTS TO BE REMOVED BY VA

STAFF.

110 GENERAL NOTE: ALL EXISTING VA EQUIPMENT TO BE

REMOVED & STORED BY CONTRACTOR SHALL BE

SECURED TO ACCEPTANCE OF VA CONTRACTING

OFFICER or THEIR REPRESENTATIVE, PHOTO DOCUMENT

AND LOG. PRIOR TO RE-INSTALLATION OF EQUIPMENT,

CONTRACTOR SHALL SCRUB CLEAN ALL EQUIPMENT

UNITS PER THEIR RESPECTIVE MANUFACTURER

SPECIFICATIONS.

114 EXISTING OMNICELL UNIT TO BE DISCONNECTED FROM

UTILITIES, REMOVED & STORED FOR REINSTALLATION.

115 EXISTING REFRIGERATOR TO BE DISCONNECTED FROM

UTILITIES, REMOVED & STORED FOR REINSTALLATION.

116 EXISTING MEDICAL SUPPLY STORAGE CABINETS TO BE

REMOVED & STORED FOR REINSTALLATION.

117 EXISTING WIRE RACK SHELVING TO BE REMOVED &

STORED FOR REINSTALLATION.

KEY PLAN

1 Coat Rack

1 Chair

9 Office Chairs

1 Refrigerator

1 Microwave

4 Computers

1 Conference Table

3 Desks

1 Locker Unit

C2337 Staff Lounge

3 Work Cubicles

1 Drawers

1 Tall Storage Cabinet

4 Computers (One with 2 monitors)

1 Metal File Drawer

1 Shredder

1 Copier

Stack of Chairs

4 Rolling Laptop

1 Work Cubicle

3 Desks

C2335 Office

1 Corner Desk

3 Computers (2 monitors each)

3 Office Chairs

1 Storage Cabinet

1 File Drawer

1 Shredder

1 Copier

3 Work Cubicles (one with drawers)

C2332 Office

1 Corner Desk

3 Computers (2 monitors each)

1 File CabinetC2331 Office

3 Corner Desks

Room Number Room Name Qty Equipment

Dietetics Equipment List

1 Rolling table

1 Helmer Medication refrigerator

3 Cardinal Health Storage HF154163 G2559B

Cardiac Cath

Support Spaces

5 Omnicell Storage

3 Rolling desks G2559 Cardiac Cath Lab

1 Philips - Azurion

Room Number Room Name Qty Equipment

Cath Lab Equipment List

C

FEC

PARTITION LEGEND:

NOTE:

-CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE COMMENCEMENT

OF WORK.

-DIMENSIONS: WALL DIMENSIONS ARE FACE OF FINISHED FACE TO

FINISHED FACE UNLESS NOTED OTHERWISE. WINDOW / DOOR

DIMENSIONS ARE TO CENTER LINE OF WINDOW / DOOR.

-ALL MTL. STUDS ARE 4" U.N.O. (MATCH FRAMING OF CURRENT

CONDITIONS AS APPLICABLE)

-WHERE DIMENSION IS PRECEEDED BY A (±) SYMBOL, THIS

REPRESENTS/ALLOWS A "FLOAT" IN LAYING OUT THE WORK.

CONTRACTOR IS TO NOTIFY ARCHITECT IN WRITING, PRIOR TO FRAMING,

IF DIMENSION EXCEED ±2" FOR DIRECTION ON HOW TO PROCEED.

(E) 1-HOUR RATED FIRE PARTITION

(E) ACOUSTICAL / NON-RATED PARTITION

(E) PARTITION TO BE DEMOLISHED

(E) 2-HOUR RATED FIRE BARRIER

201 204 206

3’−0" 3’−0"

201 204 206

621 SF

Cardiac Cath Lab

G2559

221 SF

Cardiac Cath Support Spaces G2559B

LVT-1

LVT-1 LVT-1

LVT-1 LVT-1

LVT-1

201 204 206

201 204 206

201 204 206 201 204 206

201 204 206

201 204 206

174 SF

Chief Nutrition &

Food Service C2333

75 SF

Office C2335A

261 SF

Staff Lounge (Used as Office) C2335

289 SF

Office (Used as Staff Lounge) C2337

198 SF

Office C2331

177 SF

Office C2332

2nd FLOOR - DIETETICS

2nd FLOOR - CATH LAB

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE DIETETICS &

CATH LAB FLOORING

SO/AA

AE-202

2nd FLOOR RENOVATION PLAN

(DIETETICS & CATH LAB)

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

Key Notes

201 INSTALL NEW FLOORING & INTEGRAL COVED WALL BASE

(REFER TO FINISH SCHEDULE & DETAILS).

204 GENERAL NOTE: EQUIPMENT/CARTS & FURNISHINGS

REMOVED BY VA STAFF WILL BE REPLACED BY VA STAFF

AFTER CONSTRUCTION COMPLETION.

206 GENERAL NOTE: PATCH & PAINT WALLS WHERE DAMAGED

DURING CONSTRUCTION ACTIVITIES (MATCH EXISTING

FINISHES).

KEY PLAN

1/4" = 1'-0"

2nd Floor - Cath Lab 1/4" = 1'-0"

2nd Floor - Dietetics

Rev. Date Description

08.02.2022 100% Issue for Bid

WSF-1

WSF-2

WSF-1

FLOORING:

LVT-1 LINEAR VINYL TILE

MANUFACTURER: SHAW CONTRACT

COLLECTION: TERRAIN II

SIZE : 20 MIL, 6X48

COLOR: 00774 "NEST"

WSF-1 WELDED SEAM VINYL SHEET FLOORING

MANUFACTURER: SHAW CONTRACT

COLLECTION: VITALITY 0873V

COLOR: 73755 "COMFORT"

REMARKS: 6" COVED BASE AS NEEDED

WSF-2 WELDED SEAM VINYL SHEET FLOORING

MANUFACTURER: SHAW CONTRACT

COLLECTION: VITALITY 0873V

COLOR: 73120 "UPLIFT"

REMARKS: 6" COVED BASE AS NEEDED

FINISH LEGEND:

BASE:

RB-1 RUBBER BASE

MANUFACTURER: FLEXCO

COLOR: DARK BEIGE #37

SIZE: 6"

FINISH SCHEDULE GENERAL NOTES:

1. ALL MATERIALS TO BE INSTALLED PER MANUFACTURE'S INSTRUCTIONS.

2. USE WATER-BASED EPOXY PAINT w/ SEMI-GLOSS FINISH AT TOILET ROOMS, SUB-STERILE CORE, PROCEDURE ROOMS, SOILED/CLEAN/UTILITY WORK ROOMS.

3. ALL INTEGRAL FLASH COVE BASES TO BE 4" HIGH & SUPPORTED BY A COVE SUPPORT STRIP. FINISH TOP OF COVE w/ ALUMINUM TRIM (SEAL ALL JOINTS TO WALL

SUBSTRATE). NOTED AS BASE TYPE SVB-#.

4. PROVIDE MATCHING WELD ROD AT ALL SHEET VINYL SEAMS.

5. PROVIDE BEVELED TRANSITION STRIPS AT FLOOR MATERIAL CHANGES SO THAT THE VERTICAL DIFFERENCE IN ELEVATION IS NOT GREATER THAN 1/2". FLOAT SUBSTRATE AS

NEEDED WHEN APPLICABLE.

6. MANUFACTURER’S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES AND PATTERNS. PRODUCTS OF OTHER MANUFACTURER’S EQUIVALENT TO COLORS, FINISHES, TEXTURES AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS WILL BE ACCEPTABLE UPON APPROVAL IN WRITING BY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) FOR FINISH REQUIREMENTS.

SHEET VINYL COVE BASE

WELDED SEAM

FLOORING PER

SCHEDULE

PRE-FORMED COVE STRIP

(1-1/4" RADIUS MIN.)

ALUMN. COVE CAP

1/8" RESILIENT FLOORING

ADAPTOR

1/8" RESILIENT FLOORING

TYPES OF RESILIENT

FLOORING TO INCLUDE:

- VCT

- SHEET VINYL

- STATIC DISSIPATIVE TILE

- EPOXY FLOORING

1/8" RESILIENT FLOORING (VCT,

SHEET VINYL, STATIC

DISSIPATIVE TILE, EPOXY

FLOORING)

VINYL REDUCER - JOHNSONITE

SSR-XX-B, BINDER BAR EDGING

FOR 1/16" TO 1/8" RESILIENT

FLOORING. COLOR: T.B.D.

CONCRETE

TAPE &

FINISH

CUT GYPSUM BOARD PATCH

TO FIT SNUG INTO OPENING

(TEXTURE & PAINT TO MATCH

ADJACENT)

SEALANT PER SCHEDULE

(E) PARTITION

/4

M

IN

1-1/4" TYPE S SCREWS @

8" O.C. MAX.

SECTION VIEW

(E) BOTTOM TRACK

Building Number

Drawing NumberLocation:

PhaseDrawing Title

Approved:

Issue Date Checked Drawn

StampARCHITECT / ENGINEER OF RECORDCONSULTANT

VA FORM 08 - 6231

Revisions:

MA Architects, Inc.

385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net

Planning - Architecture - Interiors

Project Number

Bldg 1 and 1D

Project Title

REPLACE DIETETICS &

CATH LAB FLOORING

SO/AA

AE-900

ROOM FINISH SCHEDULE & DETAILS

VA Project Number

654-22-003

SMc

VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502

08.02.2022

100% Contract Documents Issue for Bid

FULLY

SPRINKLERED

2165B

FINISH SCHEDULE (EXISTING)

Room

Number Room Name Area Existing Floor Existing Base

CARDIAC CATH LAB

G2559 Cardiac Cath Lab 621 WSF WSF

G2559B Cardiac Cath Support Spaces 221 WSF WSF

DIETETICS

C2333 Chief Nutrition & Food Service 174 CPT RB

C2331 Office 198 CPT RB

C2335 Staff Lounge (Used as Office) 261 CPT RB

C2335A Office 75 CPT RB

C2337 Office (Used as Staff Lounge) 289 CPT RB

C2332 Office 177 CPT RB

FINISH SCHEDULE (RENOVATION)

Room

Number Room Name Area (N) Floor (N) Base

CARDIAC CATH LAB

G2559 Cardiac Cath Lab 621 WSF-1/WSF-2 WSF-1

G2559B Cardiac Cath Support Spaces 221 WSF-1 WSF-1

DIETETICS

C2333 Chief Nutrition & Food Service 174 LVT-1 RB-1

C2331 Office 198 LVT-1 RB-1

C2335 Staff Lounge (Used as Office) 261 LVT-1 RB-1

C2335A Office 75 LVT-1 RB-1

C2337 Office (Used as Staff Lounge) 289 LVT-1 RB-1

C2332 Office 177 LVT-1 RB-1

3" = 1'-0"

2 TYP. SHEET VINYL COVING

6" = 1'-0"

RESILIENT TO RESILIENT TRANSITION

12" = 1'-0"

4 RESILIENT FLOORING TO CONC.

3" = 1'-0"

3 GYP. BRD. PATCH @ BASE

GI-000 - COVER SHEET
GI-001 - GENERAL NOTES AND STANDARDS
GI-002 - ABBREVIATIONS & SYMBOLS
GI-003 - OVERALL REFERENCE PLANS
GI-010 - PROJECT PHASING (3rd FLOOR)
GI-102 - 2nd FLOOR PHOTO REFERENCE PLAN
GI-103 - 3rd FLOOR REFERENCE PLAN
GI-103A - 3rd FLOOR PHOTOS
AD-202 - 2nd FLOOR DEMO / EQUIPMENT LIST (DIETETICS & CATH LAB)
AD-203 - 3rd FLOOR DEMO / EQUIPMENT LIST (OR SUITES)
AE-202 - 2nd FLOOR RENOVATION PLAN (DIETETICS & CATH LAB)
AE-203 - 3rd FLOOR RENOVATION PLAN (OR SUITES)
AE-203A - 3rd FLOOR OR SUITES FLOORING PATTERNS
AE-900 - ROOM FINISH SCHEDULE & DETAILS

File details come from the government source that posted it. Updated .