Attachment Exhibit A 654-22-003 Drawings.pdf
PDF 2 MB Posted
- Attached to
- Z1DB--Replace Dietetics and Cath Lab Flooring, Buildings 1 and 1D Reno, NV Project # 654-22-003 Reno, NV
- Solicitation number
- 36C26126R0038
About this file
This document is a set of contract documents for a federal construction project at the VA Sierra Nevada Healthcare System in Reno, Nevada. The project, identified as VA Project No. 654-22-003, involves the removal and replacement of existing flooring systems in the Dietetics Offices and Cardiac Cath Lab located in Buildings 1 and 1D at 975 Kirman Avenue. The total area of work encompasses 2,016 square feet, with 1,174 SF in the Dietetics area (Building 1) and 842 SF in the Cath Lab area (Building 1D).
The renovation specifies installation of new flooring materials including linear vinyl tile (LVT-1) in Dietetics offices and welded seam vinyl sheet flooring (WSF-1 and WSF-2) in the Cardiac Cath Lab, all supplied by Shaw Contract with specific color and size specifications. Wall bases will be replaced with rubber base (RB-1) in Dietetics and coved bases in the Cath Lab. The project requires contractors to remove and properly store existing equipment for reinstallation by VA staff after construction completion, patch damaged walls to match existing finishes, and comply with applicable standards including VA Design Manuals, 2018 International Building Code, NFPA codes, OSHA standards, and ASHRAE standards. Work is issued for bid at 100% contract document completion as of August 2, 2022. The project includes detailed specifications for material installation per manufacturer requirements, coordination drawings submission requirements at least 20 days prior to work commencement in each area, and comprehensive documentation of existing equipment locations and conditions prior to removal.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C26126R0038 0003.docx | DOCX document | |
| 36C26126R0038 0002.docx | DOCX document | |
| RFI Responses Replace Cath Lab.docx | DOCX document | |
| 36C26126R0038 0001.docx | DOCX document | |
| Site Visit Attendees List 05-20-2026.pdf | ||
| Attachment Price Breakdown 654-22-003.xlsx | XLSX spreadsheet | |
| 36C26126R0038_2.docx | DOCX document | |
| Attachment VAAR 852.219-75 JAN 2023 DEVIATION.pdf | ||
| Attachment SOW 654-22-003.pdf | ||
| Attachment Pre-solicitation Site Visit Presentation 654-22-003.pptx | PPTX presentation | |
| Attachment REQUEST FOR INFORMATION FORM 654-22-003.docx | DOCX document | |
| Attachment Wage Determination NV20260040 01-30-2026.pdf | ||
| Attachment 654-22-003 Specifications.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
ELEVATOR
ELEVATOR
G O
V T
G O
V T
G O
V T
G O
V T
G O
V T
G O
V T
G O
V T
118.7023
0.0184
61.8518
STOP
STOP
S
ID
E
W A L K
RAMP
R A M P
BUMPER
BUMPER
AREA OF WORK
BLDG 10 BLDG 6
BLDG 1
BLDG 12
LOCUST STREET
PARKING LOT
BLDG 1A
TAYLOR
STREET
PARKING LOT
L O
C U
S T
S
T R
E E
T
K
I
R M
A N
V E
B U R N S S T R E E T
E A S T T A Y L O R S T R E E T
BLDG 10
BLDG 1D
BLDG 5
BLDG 4
AREA OF WORK
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE OR, DIETETICS &
CATH LAB FLOORING
SO/AA
GI-000
COVER SHEET
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
PROJECT
SITE
REMOVAL AND REPLACEMENT OF EXISTING FLOORING SYSTEMS IN THE
DIETETICS OFFICES AND CARDIAC CATH LAB.
PROJECT DESCRIPTION
VICINITY MAP
DEDUCT ALTERNATES
N/A
PROJECT TEAM
FACILITY
Department of Veterans Affairs VA Sierra Nevada Healthcare System Engineering Services 975 Kirman Avenue Reno, NV 89502
ARCHITECT
MA|Architects, Inc.
385 Van Ness Ave., Suite 110 Torrance, CA 90501
Contact: Sofie O'Brien P: 424.302.5271 E: s.obrien@ma-architects.net
PROJECT DATA
PROJECT ADDRESS:
BUILDING 1
CONSTRUCTION TYPE:
STORIES:
BLDG. OCCUPANCY:
AREA OF WORK: 1,174 SF
BUILDING 1D
CONSTRUCTION TYPE:
STORIES:
BLDG. OCCUPANCY:
AREA OF WORK: 842 SF
975 KIRMAN AVENUE
RENO, NV 89502
II (SPRINKLERED)
HEALTHCARE
DIETETICS
II (SPRINKLERED)
HEALTHCARE
CATH LAB
TOTAL AREA OF WORK: 2,016 SF
DEPARTMENT OF VETERANS AFFAIRS
VA Sierra Nevada Healthcare System
975 Kirman Avenue, Reno, NV 89502
VA Project No. 654-22-003
REPLACE DIETETICS & CATH LAB FLOORING
1" = 40'-0"
Reference Site Plan
Rev. Date Description
08.02.2022 100% Issue for Bid
ARCHITECTURAL
AD-202
AE-202
AE-900
2nd FLOOR DEMO / EQUIPMENT LIST (DIETETICS & CATH LAB) 2nd FLOOR RENOVATION PLAN (DIETETICS & CATH LAB)
ROOM FINISH SCHEDULE & DETAILS
GENERAL
GI-000
GI-001
GI-002
GI-003
GI-102
COVER SHEET
GENERAL NOTES AND STANDARDS
ABBREVIATIONS & SYMBOLS
OVERALL REFERENCE PLANS
2nd FLOOR PHOTO REFERENCE PLAN
SHEET INDEX
APPLICABLE STANDARDS:
VA Directives, Design Manuals, Master Specifications, VA National CAD Standard Application Guide, and other Guidance on the Technical Information Library (TIL) (http://www.cfm.va.gov/til/).
VA PG 18-10 Architectural Design Manual (Aug. 1, 2014)
VA PG 18-10 Electrical Design Manual (Dec. 1, 2019)
2018 International Building Code (IBC) (Only when specifically referenced in VA Design Documents, see notes below)
2018 NFPA 101 Life Safety Code
2019 NFPA 241 Standard for Safeguarding Construction, Alteration, and Demolition Operations
2018 NFPA National Fire Codes with the exception of NFPA 5000 and NFPA 900
2020 NFPA 780 Standards for Installation of Lighting Protection Systems
Occupational, Safety and Health Administration (OSHA) Standards
2019 VA Seismic Design Requirements, H-18-8
2017 National Electrical Code (NEC) (NFPA 70)
2018 International Plumbing Code (IPC)
2019 Safety Code for Elevators and Escalators, American Society of Mechanical Engineers (ASME) A 17.1.
2017 ASME Boiler and Pressure Vessel Code
2019 National Roofing Contractors Associations (NRCA) Roofing Manual: Membrane Roof Systems
ASME Code for Pressure Piping
2015 Architectural Barriers Act Accessibility Standards (ABAAS) including VA supplement, Barrier Free Design Guide (PG-18-13)
Building Code Requirements for Reinforced Concrete, American Concrete Institute and Commentary (ACI 318)
Manual of Steel Construction, Load and Resistance Factor Design Specifications for Structural Steel Buildings, American Institute of Steel Construction (AISC)
Energy policy Act of 2005 (EPAct)
DOE Interim Final Rule: Energy Conservation Standards for New Federal, Commercial and Multi-Family High- Rise Residential Buildings and New Low-Rise Residential Buildings, 10 CFR Parts 433, 434 and 435.
Federal Leadership in High Performance and Sustainable Buildings: Memorandum of Understanding (MOU)
Executive Order 13423: Strengthening Federal Environmental, Energy, and Transportation Management.
Executive Order 13514: Federal Leadership in Environmental, Energy, and Economic Performance (Oct. 5, 2009)
The Provisions for Construction and Safety Signs. Stated in the General Requirements Section 01 00 00 of the VA Master Construction Specification.
Ventilation for Acceptable Indoor Air Quality - ASHRAE Standard 62.1 - 2016.
Safety Standard for Refrigeration Systems - ASHRAE Standard 15 - 2016.
Energy Standard for Buildings Except Low Rise Residential Buildings - ASHRAE 90.1 - 2016
GENERAL NOTES:
1. THE FOLLOWING GENERAL NOTES APPLY TO THE ENTIRE SET OF DRAWINGS LISTED BY
THE "INDEX OF DRAWINGS".
2. FOR GENERAL NOTES, ABBREVIATIONS, AND SYMBOLS APPLICABLE ONLY TO THE
DRAWINGS OF ONE DISCIPLINE, REFER TO THE DRAWINGS OF THAT DISCIPLINE - SEE
"INDEX OF DRAWINGS".
3. APPLICABLE PORTIONS OF THE CODES, REGULATIONS, AND STANDARDS LISTED HERE ARE
INCORPORATED BY REFERENCE INTO THE REQUIREMENTS OF THIS CONTRACT AND
ESTABLISH MINIMUM REQUIREMENTS WITH WHICH THE WORK MUST COMPLY.
THIS PROJECT AND ALL PARTS OF THE WORK ASSOCIATED WITH THE PROJECT -
INCLUDING MATERIALS, METHODS, ASSEMBLIES, ETC - SHALL COMPLY WITH ALL
APPLICABLE GOVERNING RULES, CODES, REGULATIONS, ORDINANCES, AND LAWS OF ALL
FEDERAL, STATE, DISTRICT, TERRITORIAL, AND LOCAL GOVERNMENT AUTHORITIES HAVING
JURISDICTION OVER THE DESIGN, CONSTRUCTION, AND OCCUPANCY OF THE PROJECT,
WHETHER LISTED BY THE CONTRACT DOCUMENTS OR NOT. NO PART OF THE CONTRACT
DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT WORK CONTRARY TO AN
APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE, OR LAW.
NO PART OF THE CONTRACT DOCUMENTS SHALL BE CONSTRUED TO REQUIRE OR PERMIT
WORK CONTRARY TO AN APPLICABLE GOVERNING RULE, CODE, REGULATION, ORDINANCE,
OR LAW.
4. INSTALL ALL MANUFACTURED ITEMS, MATERIALS, AND EQUIPMENT IN STRICT
ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
5. ANY WORK INSTALLED IN CONFLICT WITH THE CONTRACT DRAWINGS, CODE
REQUIREMENTS OR MANUFACTURER REQUIREMENTS WITHOUT THE PRIOR APPROVAL OF
THE GOVERNMENT AND THE ARCHITECT SHALL BE CORRECTED AT THE CONTRACTOR'S
EXPENSE. THE CONTRACTOR SHALL PROMPTLY CORRECT ALL WORK REJECTED BY THE
GOVERNMENT AS DEFECTIVE OR AS FAILING TO CONFORM TO THE CONTRACT
DOCUMENTS WHETHER OBSERVED BEFORE OR AFTER SUBSTANTIAL COMPLETION AND
WHETHER OR NOT FABRICATED, INSTALLED OR COMPLETED. THE CONTRACTOR SHALL
BEAR ALL COSTS OF CORRECTING SUCH REJECTED WORK, NOT TO BE REIMBURSED.
6. THE ARCHITECTURAL DRAWINGS ARE A PART OF A LARGER SET OF DRAWINGS WHICH,
WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE INDEX OF DRAWINGS. THE
SET OF DRAWINGS, WHEN COMPLETE, CONSISTS OF ALL DRAWINGS LISTED BY THE "INDEX
OF DRAWINGS". PARTIAL SETS OF DRAWINGS ARE INCOMPLETE.
THE WORK DESCRIBED BY THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY
THE WORK DESCRIBED ON DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURE
INSTALLATION REQUIREMENTS. SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH
OTHER, BIDS SHALL BE BASED ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND
QUANTITY OF WORK INDICATED. ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL
BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
7. THE ARCHITECTURAL FLOOR PLANS, REFLECTED CEILING PLANS, SECTIONS, AND
ELEVATIONS ILLUSTRATE THE DESIGN INTENT. THE ARCHITECTURAL DRAWINGS
ESTABLISH AND COORDINATE THE FINISHED APPEARANCE AND LOCATION OF MANY, BUT
NOT ALL, EXPOSED ELEMENTS OF THE WORK. THE STRUCTURAL, MECHANICAL,
ELECTRICAL, PLUMBING, OTHER DRAWINGS, AND JOB SPECIFICATIONS ARE
SUPPLEMENTARY TO ARCHITECTURAL WORKING DRAWINGS. THE WORK DESCRIBED BY
THE DRAWINGS OF ANY ONE DISCIPLINE MAY BE AFFECTED BY THE WORK DESCRIBED ON
DRAWINGS OF ANOTHER DISCIPLINE OR MANUFACTURER INSTALLATION REQUIREMENTS.
SHOULD THEY DISAGREE IN THEMSELVES, OR WITH EACH OTHER, BIDS SHALL BE BASED
ON THE MOST EXPENSIVE COMBINATION OF QUALITY AND QUANTITY OF WORK INDICATED.
ANY DISCREPANCY BETWEEN THESE DOCUMENTS SHALL BE IMMEDIATELY BROUGHT TO
THE ATTENTION OF THE ARCHITECT FOR CLARIFICATION.
8. THE SPECIFICATIONS ARE INTENDED TO COMMUNICATE THE DETAILED PROPERTIES AND
QUALITY OF THE INDIVIDUAL MATERIALS, ASSEMBLIES, AND SYSTEMS THAT COMPRISE THE
WORK; THE FUNCTIONAL AND PERFORMANCE REQUIREMENTS FOR THE INDIVIDUAL PARTS
OF THE WORK; AND THE FABRICATION AND INSTALLATION REQUIREMENTS FOR INDIVIDUAL
PARTS OF THE WORK - THE SPECIFICATIONS TAKE PRECEDENCE OVER THE DRAWINGS
WITH RESPECT TO INFORMATION OF THIS NATURE.
9. PROPRIETARY PRODUCTS OR ASSEMBLIES UTILIZED AS "BASIS OF DESIGN":
• ON OCCASION, THE DRAWINGS MAY REFER TO A SINGLE PROPRIETARY PRODUCT
OR ASSEMBLY WHILE THE SPECIFICATIONS LIST TWO OR MORE ACCEPTABLE
MANUFACTURES AND/OR PRODUCTS, WHEN THIS OCCURS, THE PRODUCT OR
ASSEMBLY ILLUSTRATED BY THE DRAWINGS IS THE "BASIS OF DESIGN" PRODUCT OR
ASSEMBLY.
• THE DIMENSIONS, MOUNTING HEIGHTS, CLEARANCES, AND ACCESS REQUIREMENTS
OF SPECIFIED PRODUCTS AND ASSEMBLIES OTHER THAN THE "BASIS OF DESIGN"
MAY VARY FROM THAT SHOWN BY THE DRAWINGS.
• THE CONTRACTOR MAY UTILIZE ANY OTHER SPECIFIED PRODUCT OR ASSEMBLY IN
LIEU OF THE "BASIS OF DESIGN" PRODUCT OR ASSEMBLY, AS APPROVED BY
GOVERNMENT’S REPRESENTATIVE. HOWEVER, THE CONTRACTOR IS RESPONSIBLE
(AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT) FOR ALL COORDINATION AND
REVISIONS TO DIMENSIONS AND/OR DETAILS NECESSARY TO ACHIEVE THE SAME
FUNCTIONAL AND AESTHETIC DESIGN INTENT AS ILLUSTRATED BY THE "BASIS OF
DESIGN" SHOWN BY THE CONTRACT DOCUMENTS.
10. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS ARE RESPONSIBLE FOR
EXAMINING CONTRACT DOCUMENTS, FIELD CONDITIONS, AND CONFIRMING THAT WORK IS
BUILDABLE AS SHOWN BEFORE PROCEEDING WITH CONSTRUCTION. IT IS NOT INTENDED
THAT THE CONTRACT DOCUMENTS INCLUDE EACH & EVERY SUB-SYSTEM AND/OR SUB-
COMPONENT NECESSARY TO FULLY AND PROPERLY COMPLETE THE WORK. SUB-SYSTEMS,
SUB-COMPONENTS OR DETAILS REQUIRED OR NORMALLY INCLUDED AS TRADE PRACTICE
MAY NOT BE SPECIFICALLY MENTIONED NOR SHOWN.
THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING CLARIFICATION FROM THE
ARCHITECT BEFORE PROCEEDING WITH WORK IN QUESTION OR RELATED WORK.
11. ALL WORK NOTED "N.I.C." OR "NOT IN CONTRACT" IS TO BE ACCOMPLISHED BY A
CONTRACTOR OTHER THAN THE GENERAL CONTRACTOR AND IS NOT TO BE PART OF THE
CONSTRUCTION AGREEMENT. THE GENERAL CONTRACTOR IS SOLELY RESPONSIBLE TO
COORDINATE WITH ALL "OTHER" CONTRACTORS PER REQUIREMENTS ESTABLISHED BY
GOVERNMENT, WHICH ARE UNDER SEPARATE CONTRACT WITH THE GOVERNMENT.
12. THE ARCHITECT / ENGINEERS SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL NOT
BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCE ON
PROCEDURE, OR FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE
WORK, ALL OF WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL
CONTRACTOR.
13. IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW AND COORDINATE THE WORK OF
ALL SUBCONTRACTORS, TRADES, AND SUPPLIERS WITH ALL REQUIREMENTS OF THE
CONTRACT DOCUMENTS BEFORE COMMENCING CONSTRUCTION, AND TO ASSURE THAT
ALL PARTIES ARE AWARE OF ALL REQUIREMENTS, REGARDLESS OF WHERE THE
REQUIREMENTS OCCUR IN THE CONTRACT DOCUMENTS, WHICH MIGHT AFFECT THE WORK
OF THAT PARTY.
CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES
NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,
DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED
IN THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING, FITTING OR PATCHING THAT
MAY BE REQUIRED TO COMPLETE WORK OR TO MAKE ITS SEVERAL PARTS FIT TOGETHER.
GENERAL NOTES CONTINUED:
13. THE THE CONTRACTOR SHALL, IN ADVANCE OF THE WORK, PREPARE COORDINATION
DRAWINGS SHOWING THE LOCATION OF OPENINGS THROUGH SLABS, THE PIPE SLEEVES
AND HANGER INSERTS, AS WELL AS THE LOCATION AND ELEVATION OF UTILITY LINES,
INCLUDING, BUT NOT LIMITED TO, CONVEYOR SYSTEMS, PNEUMATIC TUBES, DUCTS, AND
CONDUITS AND PIPES TWO INCHES AND LARGER IN DIAMETER. THESE DRAWINGS,
INCLUDING PLANS, ELEVATIONS, AND SECTIONS AS APPROPRIATE, SHALL CLEARLY SHOW
THE MANNER IN WHICH THE UTILITIES FIT INTO THE AVAILABLE SPACE AND RELATE TO
EACH OTHER AND TO EXISTING BUILDING ELEMENTS. DRAWINGS SHALL BE OF
APPROPRIATE SCALE TO SATISFY THE PREVIOUSLY STATED PURPOSES, BUT NOT
SMALLER THAN 3/8-INCH SCALE. DRAWINGS MAY BE COMPOSITE (WITH DISTINCTIVE
COLORS FOR THE VARIOUS TRADES) OR MAY BE SEPARATE BUT FULLY COORDINATED
DRAWINGS (SUCH AS SEPIAS OR PHOTOGRAPHIC PAPER REPRODUCIBLE) OF THE SAME
SCALE. SEPARATE DRAWINGS SHALL DEPICT IDENTICAL BUILDING AREAS OR SECTIONS
AND SHALL BE CAPABLE OF BEING OVERLAID IN ANY COMBINATION. THE SUBMITTED
DRAWINGS FOR A GIVEN AREA OF THE PROJECT SHALL SHOW THE WORK OF ALL TRADES
THAT WILL BE INVOLVED IN THAT PARTICULAR AREA. COMPLETE COMPOSITE DRAWINGS
OR SIX COMPLETE SETS OF SEPARATE REPRODUCIBLE DRAWINGS SHALL BE RECEIVED BY
THE GOVERNMENT NOT LESS THAN 20 DAYS PRIOR TO THE SCHEDULED START OF THE
WORK IN THE AREA ILLUSTRATED BY THE DRAWINGS, FOR THE PURPOSE OF SHOWING
THE CONTRACTOR’S PLANNED METHODS OF INSTALLATION. THE OBJECTIVES OF SUCH
DRAWINGS ARE TO PROMOTE CAREFULLY PLANNED WORK SEQUENCE AND PROPER
TRADE COORDINATION, IN ORDER TO ASSURE THE EXPEDITIOUS SOLUTIONS OF
PROBLEMS AND THE INSTALLATION OF LINES AND EQUIPMENT AS CONTEMPLATED BY THE
CONTRACT DOCUMENTS WHILE AVOIDING OR MINIMIZING ADDITIONAL COSTS TO THE
CONTRACTOR AND TO THE GOVERNMENT. IN THE EVENT THE CONTRACTOR, IN
COORDINATING THE VARIOUS INSTALLATIONS AND IN PLANNING THE METHOD OF
INSTALLATION, FINDS A CONFLICT IN LOCATION OR ELEVATION OF ANY OF THE UTILITIES
WITH THEMSELVES, WITH STRUCTURAL ITEMS OR WITH OTHER CONSTRUCTION ITEMS,
HE/SHE SHALL BRING THIS CONFLICT TO THE ATTENTION OF THE CONTRACTING OFFICER
IMMEDIATELY. IN DOING SO, THE CONTRACTOR SHALL EXPLAIN THE PROPOSED METHOD
OF SOLVING THE PROBLEM OR SHALL REQUEST INSTRUCTIONS AS TO HOW TO PROCEED
IF ADJUSTMENTS BEYOND THOSE OF USUAL TRADES’ COORDINATION ARE NECESSARY.
UTILITIES INSTALLATION WORK WILL NOT PROCEED IN ANY AREA PRIOR TO THE
SUBMISSION AND COMPLETION OF THE GOVERNMENT REVIEW OF THE COORDINATED
DRAWINGS FOR THAT AREA, NOR IN ANY AREA IN WHICH CONFLICTS ARE DISCLOSED BY
THE COORDINATION DRAWINGS, UNTIL THE CONFLICTS HAVE BEEN CORRECTED TO THE
SATISFACTION OF THE CONTRACTING OFFICER. IT IS THE RESPONSIBILITY OF THE
CONTRACTOR TO SUBMIT THE REQUIRED DRAWINGS IN A TIMELY MANNER CONSISTENT
WITH THE REQUIREMENTS TO COMPLETE THE WORK COVERED BY THIS CONTRACT WITHIN
THE PRESCRIBED CONTRACT TIME.
14. CONTRACTOR SHALL SUPPLY ALL LABOR, MATERIALS, EQUIPMENT, TOOLS AND SERVICES
NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF ALL WORK SHOWN,
DESCRIBED, OR REASONABLY IMPLIED, BUT NOT LIMITED TO THAT EXPLICITLY INDICATED
IN THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
CUTTING, FITTING OR PATCHING THAT MAY BE REQUIRED TO COMPLETE WORK OR TO
MAKE ITS SEVERAL PARTS FIT TOGETHER. THE GENERAL CONTRACTOR IS RESPONSIBLE
TO REVIEW AND COORDINATE THE WORK OF ALL SUBCONTRACTORS, TRADES, AND
SUPPLIERS WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS.
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE DIETETICS &
CATH LAB FLOORING
SO/AA
GI-001
GENERAL NOTES AND STANDARDS
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
PROJECT GENERAL NOTES
APPLICABLE STANDARDS
Rev. Date Description
08.02.2022 100% Issue for Bid
ABC
AGGREGATE BASE COURSE
BB
B
BULLETIN BOARD
BD BOARD
BD FT
BHMA
BOARD FEET (FOOT)
BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BI FLD DR BIFOLDING DOORS
BEV BEVEL
BITUM BITUMINOUS
BKG BACKING
BLD BUILD
CAB
C
CABINET
CB CATCH BASIN
CCT
CG
CUBICLE CURTAIN TRACK
CORNER GUARD
CEM
CER
CEMENT, CEMENTITIOUS
CERAMIC
CCTV CLOSED CIRCUIT TELEVISION
CH BD CHALKBOARD
CI CAST IRON
CJ CONTROL JOINT
CL
CLG
CLR
CMU
CNTR
COL
CONC
CONF
CONN
CONSTR
CONT
CONTR
CORR
CPT
CSK
CSP
CSWK
CU
CW
CENTER LINE
CEILING
CLEAR
CONCRETE MASONRY UNIT
COUNTER
COLUMN
CONCRETE
CONFERENCE
CONNECTION
CONSTRUCTION
CONTINUOUS
CONTRACTOR
CORRUGATED
CARPET
COUNTERSUNK
COMBINATION STANDPIPE
CASEWORK
CUBIC
COLD WATER
D
D
DEPTH
DBL DOUBLE
DBL ACT DOUBLE ACTING
DEG DEGREE
DEMO DEMOLISH
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIFF DIFFUSER
DIM DIMENSION
DIM PT DIMENSION POINT
DISP DISPENSER
DIST DISTANCE
DN DOWN
DR DRAIN
DS DOWNSPOUT
DSP DRY STANDPIPE
DT DRAPERY TRACK
DWG DRAWING
DWGS DRAWINGS
(E)
E
EXISTING
EA EACH
EDR EQUIPMENT DRAWING
EG EDGE GUARD
EIFS EXTERIOR INSULATION FINISH SYSTEM
EL ELEVATION
ELAST ELASTOMERIC
ELEC ELECTRICAL
ELEV ELEVATOR
EMER EMERGENCY
ENCL ENCLOSURE
ENGR ENGINEER
EOS EDGE OF SLAB
EP ELECTRICAL PANEL
EPB ELECTRICAL PANEL BOARD
EPDM ETHYLENE PROPYLENE DIENE MONOMER
EQ EQUAL
EQL SP EQUALLY SPACED
EQUIP EQUIPMENT
EQUIV EQUIVALENT
ESCAL ESCALATOR
EST ESTIMATE(D)
EWC ELECTRIC WATER COOLER
EXC EXCAVATED
EXH EXHAUST
EXP EXPANSION
EXP JT EXPANSION JOINT
FURN FURNITURE
FXTR FIXTURE
G
G
GAS
H
H
HIGH
GA GAUGE, GAGE
GAL GALLON
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GFRP GLASS FIBER REINFORCED PLASTIC
GLU LAM GLUE LAMINATED
GLZ GLAZING
GR GRADE OR GRADING
GVL GRAVEL
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
ID
I
INSIDE DIAMETER
JAN
J
JANITOR
KG
K
KILOGRAM
L
L
LENGTH, LONG
M
(N) N
NA
NAAMM
NAT
NATL
NC
NCOMBL
NEC
NEG
NEMA
NEUT
NFC
NFPA
NIC
NO
NOM
NR
NRC
NRCA
NRP
NS
NUM
N
NEW
NORTH
NOT APPLICABLE
NATIONAL ASSOCIATION OF
ARCHITECTURAL METAL MANUFACTURERS
NATURAL
NATIONAL
NOISE CRITERIA
NONCOMBUSTIBLE
NATIONAL ELECTRICAL CODE
NEGATIVE
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NEUTRAL
NATIONAL FIRE CODE
NATIONAL FIRE PROTECTION
ASSOCIATION
NOT IN CONTRACT
NUMBER
NOMINAL
NOISE REDUCTION
NOISE REDUCTION COEFFICIENT
NATIONAL ROOFING CONTRACTORS
ASSOCIATION
NONREMOVABLE
NARROW STILE
NUM NUMERAL
P
QA
QC
QRY
QT
QTB
QTF
QTR
QTY
QUAD
QUAL
Q
QUALITY ASSURANCE
QUALITY CONTROL
QUARRY
QUARRY TILE
QUARRY TILE BASE
QUARRY TILE FLOOR
QUARTER
QUANTITY
QUADRANT
QUALITY
R
R
RISER
S
SA
SALV
SAMP
SAN
SAT
SATC
SB
SBS
SBSTR
SC
SCH
SCHED
SCHEM
SCP
SCRN
SCT
SCWD
SD
SDG
SECT
SEG
SEL
SEP
SF
SFTWD
SGD
SGL
SHR
SHR HD
SHRH
SHT
SHT MTL
SHTHG
SHV
SIM
SJ
SJI
SK
SKLT
SLD WDW
SLDG
SLNT
SM
SMK
SND
SND INS
SNDU
SPEC
SPKLR
SPKR
SPLY
SQ
SQ IN
SQ YD
SS
SST
ST
STC
STD
STIF
STL JST
STL LNTL
STL PL
STL RF DK
STL TB
STL TR
STNLS
STOR
STR
STRUCT
SUB
SURF
SUSP
SUSP CLG
SV
SW
SWDR
SYM
SYNTH
SYS
SOUTH
SUPPLY AIR
SALVAGE
SAMPLE
SANITARY
SUSPENDED ACOUSTICAL TILE
SUSPENDED ACOUSTICAL TILE CEILING
SPLASH BLOCK
STYRENE BUTADIEN STYRENE
SUBSTRATE
SHADING COEFFICIENT OR SOLID CORE
SCHOOL
SCHEDULE
SCHEMATIC
SCUPPER
SCREEN
STRUCTURAL CLAY TILE
SOLID CORE WOOD DOOR
SHOP DRAWINGS, SMOKE DETECTOR,
OR SOAP DISPENSER
SIDING
SECTION
SEGMENT
SELECT
SEPARATE
SQUARE FOOT (FEET)
SOFTWOOD
SLIDING GLASS DOOR
SINGLE
SHOWER
SHOWER HEAD
SHOWER DRAIN
SHEET
SHEET METAL
SHEATHING
SHELVING
SIMILAR
SCORED JOINT
STEEL JOIST INSTITUTE
SKETCH
SKYLIGHT
HORIZONTAL SLIDING WINDOW
SLIDING
SEALANT
SHEET METAL
SMOKE
SANITARY NAPKIN DISPENSER
SOUND INSULATION
SANITARY NAPKIN DISPOSAL UNIT
SPECIFICATION
SPRINKLER
SPEAKER
SUPPLY
SQUARE
SQUARE INCH
SQUARE YARD
SANITARY SEWER OR SERVICE SINK
STAINLESS STEEL
STAIRS OR STREET
SOUND TRANSMISSION CLASS
STANDARD
STIFFENER
STEEL JOIST
STEEL LINTEL
STEEL PLATE
STEEL ROOF DECK
STEEL TUBE
STEEL TRUSS
STAINLESS
STORAGE
STRINGERS
STRUCTURAL
SUBSTITUTE
SURFACE
SUSPEND
SUSPENDED CEILING
SHEET VINYL
SWITCH
SWING DOOR
SYMBOL
SYNTHETIC
SYSTEM
T T&G T&M
TB
TCA
TCP
TD
TECH
TEL
TEMP
TER
THD
THERM
THK
THRES
THRU
THRUOUT
TK BD
TMPD
TMPD GL
TN
TO
TO FDN
TOB
TOM
TOP
TOS
TOW
TPD
TPH
TR
TRANS
TRANS WD FIN
TRTD
TS
TSTAT
TV
TYP
T
TREAD
TONGUE AND GROOVE
TIME AND MATERIALS
THROUGH BOLT OR TOWEL BAR
TILE COUNCIL OF AMERICA
TELEPHONE CONTROL PANEL TEMPERATURE
TRAFFIC CONTROL PLAN
TOWEL DISPENSER
TECHNICAL
TELEPHONE
TEMPERATURE OR TEMPORARY
TERRAZZO
THREAD
THERMAL
THICKNESS
THRESHOLD
THROUGH
THROUGHOUT
TACKBOARD
TEMPERED
TEMPERED GLASS
TRUE NORTH
TOP OF
TOP OF FOUNDATION
TOP OF BEAM
TOP OF MANSORY
TOP OF PARAPET
TOP OF STEEL
TOP OF WALL
TOILET PAPER DISPENSER
TOILET PAPER HOLDER
TOWEL BACK
TRANSOM
TRANSPARENT WOOD FINISH
TREATED
TENSILE STRENGHTH OR TUBE STEEL
THERMOSTAT
TELEVISION
TYPICAL
W
W
WEST
XFMR
X BRACE
XPS
X
TRANSFORMER
CROSS BRACE
EXTRUDED POLYSTYRENE BOARD
(INSULATION)
YD
YR
Y
YARD
YEARHB HOSE BIBB
HC HOLLOW CORE
HD HEAD
HDBD HARDBOARD
HDW HARDWARE
HDWD HARDWOOD
HGT HEIGHT
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HPT HIGH POINT
HR HOUR
HVAC HEATING-VENTILATION-AIR CONDITIONING
IN INCH
INCAND INCANDESCENT
INCL INCLUDE, INCLUDING
INFO INFORMATION
INSUL INSULATION
INT INTERIOR
INV INVERT
IVT INTRAVENOUS TRACK
JST JOIST
JT JOINT
KIT KITCHEN
KPL KICK PLATE
KS KNEE SPACE
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAM GL LAMINATED GLASS
LAU LAUNDRY
LAV LAVATORY
LBR LUMBER
LBS POUND
LD BRG LOAD-BEARING
LDR LEADER
LED LIGHT EMITTING DIODE
LH LEFT HAND
LHR LEFT HAND REVERSE
LIB LIBRARY
S
MACH
MACH RM
MAINT
MAN
MATL
MATV
MAX
MB
MCB
MD
ME
MEAS
MECH
MECH RM
MED
MED
MEK
MEL
MEMB
MEMO
MEZZ
MF
MFD
MFG
MFR
MFR REC
MGT
MH
MIC
MID
MIL STD
MIN
MIRR
MISC
MIT
MKR
ML
MLDG
MLWK
mm
PAR
PARA
PART
PAT
PA
PB
PBD
PC
PCA
PCC
PCCP
PCD
PCF
PCP
PED
PEN
PEND
PERF
PERM
PERIM
PERP
PGBD
PHAR
PHOTO
PHS
PKG
PI
PL
PL GL
PLAM
PLAS
PLBG
PLYWD
PMTL
PNEU
PNL
PO
PO
POLY
PR
PRCST
PREFAB
PREFIN
PRELIM
PREP
PRESS
PREV
PRKG
PRMLD
PROJ
PROP
PSF
PSI
PT
PTD
PTN
PVC
PVG
PWR
PARALLEL OR PARAPET
PARAGRAPH
PARTIAL
PATTERN
PUBLIC ADDRESS
PUSHBUTTON
PARTICLEBOARD
PIECE, POLYCARBONATE OR PORTLAND
CEMENT
PORTLAND CEMENT ASSOCIATION
PRECAST CONCRETE
CONCRETE PAVEMENT
PAPER CUP DISPENSER
POUNDS PER CUBIC FOOT
PORTLAND CEMENT PLASTER
PEDESTAL
PENETRATE
PENDANT
PERFORATED
PERMANENT
PERIMETER
PERPENDICULAR
PEGBOARD
PHARMACY
PHOTOGRAPH
PHILLIPS HEAD SCREW
PACKAGE
POINT OF INTERSECTION
PROPERTY LINE
PLATE GLASS
PLASTIC LAMINATE
PLASTER OR PLASTIC
PLUMBING
PLYWOOD
PAINTED METAL
PNEUMATIC
PANEL
POST OFFICE PURCHASE ORDER
PURCHASE ORDER POST OFFICE
POLYETHYLENE (PLASTIC)
PAIR
PRECAST
PREFABRICATE
PREFINISH
PRELIMINARY
PREPARATION
PRESSURE
PREVIOUS
PARKING
PREMOLDED
PROJECT
PROPERTY
POUNDS PER SQUARE FOOT
POUNDS PER SQUARE INCH
PAINT, PNEUMATIC TUBE, OR
PRESSURE TREATED
PAPER TOWEL DISPENSER
PARTITION
POLYVINYL CHLORIDE (PLASTIC)
PAVING
POWER
RA RETURN AIR
RAD RADIUS
RB RESILIENT BASE
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
RD ROOF DRAIN
RECT RECTANGULAR
REF REFERENCE
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE (D) (ING) (MENT)
REQD REQUIRED
REQT REQUIREMENT
RESIL RESILIENT
RET RETURN
REV REVISION
RF RESILIENT FLOORING
RH RIGHT HAND
RHMS ROUND HEAD MACHINE SCREW
RHWS ROUND HEAD WOOD SCREW
RM ROOM
RND ROUND
RO ROUGH OPENING
ROW RIGHT OF WAY
RWL RAIN WATER LEADER
UC
U
UNDER COUNTER
UL UNDERWRITERS LABORATORIES
UON UNLESS OTHERWISE NOTED
UPS UNINTERRUPTABLE POWER SUPPLY
UTIL
UCD
UGND
ULT
UNFIN
UR
UV
UTILITY
UNDERCUT DOOR
UNDERGROUND
UNTIMATE
UNFINISH
URINAL
ULTRAVIOLET
W/ WITH
W/O WITHOUT
WC WATER CLOSET OR WALL COVERING
WD WOOD
WDW WINDOW
WGL WIRE GLASS
WCHR WHEELCHAIR
WM WIRE MESH
WO WHERE OCCURS
WPT WORKING POINT
WR WATER RESISTANT
WSCT WAINSCOT
WSP WET STANDPIPE
WT WEIGHT
WTHPRF WEATHERPROOF
WTRPRF WATERPROOF
WWF WELDED WIRE FABRIC
WWM
WARR
WBL
WC WL HNG
WCL WL MTD
WF
WFAB
WFR
WFS
WH
WHSE
WLD
WP
WPD
WPM
WS
WELDED WIRE MESH
WARRANTY
WOOD BLOCKING
WATER CLOSET, WALL HUNG
WATER COOLER, WALL HUNG
WIDE FLANCE
WALL FABRIC
WOOD FRAME
WOOD FURRING STRIPS
WATER HEATER
WAREHOUSE
WELDED
WATERPROOFING
WATER PRESSURE DROP
WATERPROOF MEMBRANE
WEATHERSTRIP
CCR CARD CONTROL READER
BLDG BUILDING
CT CERAMIC TILE
F
F/F FACE TO FACE
FA FIRE ALARM
FAS FIRE ALARM STATION OR FASCIA
FB FLAT BAR
FCU FAN COIL UNIT
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FEC FIRE EXTINGUISHER CABINET
FE FIRE EXTINGUISHER
FF FINISH FACE
FHC FIRE HOSE CABINET
FHMS FLAT HEAD MACHINE SCREW
FHWS FLAT HEAD WOOD SCREW
FHY FIRE HYDRANT
FLAM FLAMMABLE
FLASH FLASHING
FLEX FLEXIBLE
FLUOR FLUORESCENT
FO FACE OF OR FINISHED OPENING
FSB FOLDING SHOWER BENCH
FSTNR FASTENER
FT FOOT, FEET
O/O O
OA
OC
OCC
OCT
OD
OD
OF/CI
OFD
OFF
OF/OI
OH
OH DR
OPH
OPNG
OPP
OPR
OPT
OR
ORD
ORG
ORIG
ORN
OSHA
OUT
OZ
OVHD
O
OUT TO OUT
OXYGEN
OUTSIDE AIR OR OVERALL
ON CENTER
OCCUPY
OCTAGON
OUTSIDE DIAMETER OUTSIDE
DIMENSION
OUTSIDE DIMENSION OUTSIDE
DIAMETER
OWNER FURNISHED/CONTRACTOR
INSTALLED
OVERFLOW DRAIN
OFFICE
OWNER FURNISHED/OWNER INSTALLED
OVERHANG
OVERHEAD (COILING) DOOR
OPPOSITE HAND
OPENING
OPPOSITE
OPERABLE
OPTIONAL
OPERATING ROOM OR OUTSIDE RADIUS
ORDNANCE OR OVERFLOW ROOF
DRAIN
ORGANIC
ORIGINAL
ORNAMENTAL
OCCUPATIONAL SAFETY AND HEALTH
ADMINSTRATION
OUTLET
OUNCE
OVERHEAD
VAC
V
VACUUM
VB VALVE BOX
VCT VINYL COMPOSITION TYLE
VERT VERTICAL
VEST VESTIBULE
VIT VITREOUS
VP VENT PIPE
VOL VOLUME
VWC VINYL WALL COVERING
ABBREVIATIONS SYMBOLS
ANGLE
@ AT
C CENTER LINEL
Ø DIAMETER
= EQUAL
> GREATER THAN
< LESS THAN
± PLUS OR MINUS (TOLERANCE)
# POUND(S)
' FOOT OR FEET
" INCH OR INCHES
FOF FACE OF FINISH
HSS HOLLOW STRUCTURAL STEEL
SYMBOLS LEGENDS
SHEET
NORTH IDENTIFIER
ELEVATION
IDENTIFIER
KEY NOTE TAG
GRID LINES
CALL-OUT IDENTIFIER
? PHOTOGRAPH
LOCATIONS
+? CEILING TAG
? WALL TYPE TAG
SHEET #
REF # ON SHEET
WINDOW TAG
DOOR TAG?
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT
AAMA
AIR CONDITIONING UNIT
AMERICAN ARCHITECTURAL
MANUFACTURERS ASSOCIATION
A/E ARCHITECT / ENGINEER
AB ANCHOR BOLT
AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE
ACI AMERICAN CONCRETE INSTITUTE
ACS DR ACCESS DOOR
ACS FLR ACCESS FLOOR
ACST ACOUSTIC
ACS PNL ACESS PANEL
ACT ACOUSTICAL CEILING TILE
AD AREA DRAIN
ADA AMERICANS WITH DISABILITIES ACT
ADC AUTOMATIC DOOR CLOSER
ADDL ADDITIONAL
ADH ADHESIVE
ADDN ADDITION
ADJ ADJACENT, ADJOINING, OR ADJUSTABLE
ADMIN ADMINISTRATION
ADB AUTOMATIC DOOR BOTTOM
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGC ASSOCIATED GENERAL CONTRACTORS
AGA AMERICAN GAS ASSOCIATION
AGGR AGGREGATE
AHJ AUTHORITY HAVING JURISDICTION
AHR ANCHOR
AHU AIR HANDLING UNIT
AIA AMERICAN INSTITUTE OF ARCHITECTS
ALT ALTERNATE
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
ALT NO ALTERNATE NUMBER
ALUM ALUMINUM
AMP AMPERE
AMT AMOUNT
ANOD ANODIZE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
ANT ANTENNA
APA AMERICAN PLYWOOD ASSOCIATION
APPD APPROVED
APPROX APPROXIMATE
APT APARTMENT
AR AS REQUIRED
ARCH ARCHITECT
ASB ASBESTOS
ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION
ASKLR AUTOMATIC SPRINKLER
ASPH ASPHALT
ASSN ASSOCIATION
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
ATCH ATTACHMENT
ATM AUTOMATIC TELLER MACHINE
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AUX AUXILIARY
AV AUDIO VISUAL
AVE AVENUE
AVG AVERAGE
AW ACID WASTE
AWI ARCHITECTURAL WOODWORKING INSTITUTE
AWPA AMERICAN WOOD PRESERVERS' ASSOCIATION
AWS AMERICAN WELDING SOCIETY
AWT ACOUSTICAL WALL TREATMENT
BLKT BLANKET
BLVD BOULEVARD
BM
BR
BEAM OF BENCHMARK
BEDROOM
BRCG
BRDG
BRACING
BRIDGING
BOT BOTTOM
BRDG JST BRIDGING JOIST
BRG BEARING
BRG PL BEARING PLATE
BRKT BRACKET
BRZ BRONZE
BSMT BASEMENT
BTWN BETWEEN
BU BUSHEL
BUR BUILT–UP ROOFING
C CELCIUS CHANNEL
C CONC CAST CONCRETE
C TO C
CBB
CENTER TO CENTER
CEMENTITIOUS (BACKER) BOARD
CC
CCW
CUBIC CENTIMETER
COUNTERCLOCKWISE
CAC CEILING ATTENUATION CLASS
CD CONSTRUCTION DOCUMENTS OR CONTRACT
DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI
CF/OI
CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
C LABEL CLASS C DOOR
CFLG
CFM
COUNTERFLASHING
CUBIC FEET PER MINUTE
CFS CUBIC FEET PER SECOND
CG CENTER OF GRAVITY OR CORNER GUARD
CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS
CHEM
CHFR
CHK
CI
CIP
CIR
CIRC
CNR
CNTR
CO
CONC FLR
COND
CONF
CORR
CMP
CRS
CRSI
CHEMICAL
CHAMFER
CHECK
CAST IRON
CAST–IN–PLACE
CIRLCE
CIRCULAR
CORNER
COUNTER
CARBON MONOXIDE, CERTIFICATE OF
OCCUPANCY, CLEANOUT, OR COMPANY
CONCRETE FLOOR
CONDENSER OR CONDITION
CONFERENCE
CORRIDOR
CRITICAL PATH METHOD
COLD ROLLED STEEL
CONCRETE REINFORCING STEEL INSTITUTE
CPRS COMPRESSIBLE
CSB CONCRETE SPLASH BLOCK
CSG CASING
CSK
CSWK
COUNTER SUNK
CASEWORK
CTB
CTF
CERAMIC TILE BASE
CERAMIC TILE FLOOR
CSMT CASEMENT
CTG
CSI CONSTRUCTION SPECIFICATIONS INSTITUTE
COATING
CTRL CONTROL
CU FT
CU IN
CUBIC FEET
CUBIC INCH
CTR CENTER CONTOUR
CU YD CUBIC YARD
CURT
CYL
CURTAIN
CYLINDER
CYL L CYLINDER LOCK
D LABEL CLASS D DOOR
DAT DATUM
DB DECIBEL
DBL GLZ DOUBLE GLAZE
DC DIRECT CURRENT
DEL DELETE
DIR DIRECTION
DIV DIVIDE OR DIVISION
DL DEAD LOAD
DOC DOCUMENT
DOUG FIR DOUGLAS FIR
DOZ DOZEN
DR CL DOOR CLOSER
DR FR DOOR FRAME
DR OPNG DOOR OPENING
DSGN DESIGN
DW DISHWASHER
DWTR DUMBWATER
E EAST
E LABEL CLASS E DOOR
EFF EFFICIENCY
EFS EXTERIOR FINISH SYSTEM
EJ EXPANSION JOINT
EMER SHR EMERGENCY SHOWER
ENCL ENCLOSURE
ENVIR ENVIRONMENT
EPA ENVIRONMENTAL PROTECTION AGENCY
EPO EMERGENCY POWER OFF
EPS EXPANDED POLYSTRYRENE BOARD
(INSULATION)
ERD EXISTING ROOF DRAIN
ESC ESCAPE OR ESCUTCHEON
ESMT EASEMENT
ESP ESPECIALLY
ETC ET CETERA
EW EACH WAY
EWS EYE WASH STATION
EXH EXHAUST
EXIST EXISTING
EXP BT EXPANSION BOLT
EXST GR EXISTING GRADE
EXT EXTERIOR, EXTERNAL, OR
EXTINGUISHER
EXT GR EXTERIOR GRADE
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
F FAHRENHEIT OR FEMALE
FAB FABRIC
FAC FACTOR
FACIL FACILITY
FAS BD FASCIA BOARD
FCO FLOOR CLEANOUT
FCTY FACTORY
FDTN FOUNDATION
FF EL FINISH FLOOR ELEVATION
FF&E FURNITURE, FIXTURE, AND EQUIPMENT
FH FLAT HEAD
FIG FIGURE
FIL FILLET
FIN FINISH
FHP FULL HEIGHT PARTITION
FLG FLOORING
FLR FLOOR
FIN WD FINISH WOOD
FIXT FIXTURE
FLDG FOLDING
FL FLOORLINE
FLUOR FIX FLUORESCENT FIXTURE
FM FACTORY MUTUAL
FLR FIN FLOOR FINISH
FLR SK FLOOR SINK
FRZ FREEZER
FM–G FACTORY MUTUAL GLOBAL
FOC FACE OF CONCRETE OR FACE OF CURB
FOF FACE OF FINISH
FOM FACE OF MANSORY
FOS FACE OF SLAB OR FACE OF STUD
FOUNT FOUNTAIN
FOW FACE OF WALL
FP FIRE PROTECTION OR FIREPROOF
FPM FEET PER MINUTE
FPS FEET PER SECOND
FR FIRE RATING, FIRE RESISTANT, OR FRAME
FREQ FREQUENCY
FRMG FRAMING
FRP FIBER REINFORCED POLYESTER OR
FIBERGLASS REINFORCED PLASTIC
FR SINK FLUSHING RIM SINK
FS FEDERAL SPECIFICATION
FURG FURRING
FWC FABRIC WALLCOVERING
FUT FUTURE
GD GUARD
GDR GUARD RAIL
GEN GENERAL OR GENERATOR
GL GLASS
GI GRAB BAR OR GALVANIZED IRON
GC GENERAL CONTRACTOR
GFRC GLASS FIBER REINFORCED CONCRETE
GFRG GLASS FIBER REINFORCED GYPSUM
GL GLASS
GL BLK GLASS BLOCK
GR FL GROUND FLOOR
GRAN GRANITE
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
GT GROUT
GUAR GUARANTEE
GUT GUTTER
GRTG GRATING
GSB GYPSUM SHEATHING BOARD
GSM GALVANIZED SHEET METAL
GSU GLAZED STRUCTURAL UNIT
H PLAM HIGH PRESSURE PLASTIC LAMINATE
HAZ MAT HAZARDOUS MATERIALS
HCWD HOLLOW CORE WOOD DOOR
HDNR HARDENER
HDO HIGH DENSITY OVERLAY
HDR HEADER
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HEX HEXAGON
HF HIGH FREQUENCY
HGR HANGER
HMD HOLLOW METAL DOOR
HMDF HOLLOW METAL DOOR AND FRAME
HMF HOLLOW METAL FRAME
HO HOLD OPEN
HOSP HOSPITAL
HP HIGH PRESSURE OR HORSEPOWER
HQ HEADQUARTERS
HS HEAT-STRENGTHENED (GLASS) OR
HIGH STRENGTH
HSE HOUSE
HSKPG HOUSEKEEPING
HST HOIST
HT HEIGHT
HVY HEAVY
HW HOT WATER
HYD HYDRANT
HYDR HYDRAULIC
I INTERSTATE (HIGHWAY) OR MOMENT
OF INERTIA
IAQ INDOOR AIR QUALITY
IBC INTERNATIONAL BUILDING CODE
ID NO IDENTIFICATION NUMBER
ILLUM ILLUMINATION
IND INDEPENDENT OR INDUSTRIAL
INFO INFORMATION
INSUL INSULATION
INTERCOM INTERCOMMUNICATION
INTL INTERNATIONAL
IRMA INVERTED ROOF MEMBRANE ASSEMBLY
IWH INSTANTANEOUS WATER HEATER
J-BOX JUNCTION BOX
KD KILN DRIED
KO KNOCKOUT
LIN LINEAR
LINO LINOLEUM
LIQ LIQUID
LKR LOCKER
LKR RM LOCKER ROOM
LKWASH LOCKWASHER
LL LEAD LINED
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LMST LIMESTONE
LNDSCP LANDSCAPE
LR LIVING ROOM
LRG LARGE
LRV LOUVERED ROOF VENT
LS LUMP SUM
LT LIGHT
LT GA LIGHT GAGE
LT WT LIGHTWEIGHT
LTG LIGHTING
LTNG LIGHTNING
LVD LOUVERED
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
LWIC LIGHTWEIGHT INSULATING CONCRETE
LYR LAYER
MACHINE
MACHINE ROOM
MAINTENANCE
MANUAL
MATERIAL
MASTER ANTENNA TELEVISION SYSTEM
MAXIMUM
MACHINE BOLT
METAL CORNER BEAD
DECK
MECHANICAL ENGINEER
MEASURE
MECHANICAL
MECHANICAL ROOM
MEDICAL MEDIUM
MEDIUM MEDICAL
METHYL ETHYL KETONE
MELAMINE
MEMBRANE
MEMORANDUM
MEZZANINE
MILL FINISH
MANUFACTURED
MANUFACTURING
MANUFACTURER
MANUFACTURER'S RECOMMENDATION
MANAGEMENT
MANHOLE
MICROPHONE
MIDDLE
MILITARY STANDARD
MINIMUM MINUTE
MIRROR
MISCELLANEOUS
MITER
MARKER
METAL LATH
MOLDING (MOULDING)
MILLWORK
MILLIMETER
MO
MOD
MOD BIT
MON
MOPR
MR
MS
MTD
MTG
MTL
MULL
MW
MWP
MASONRY OPENING OR MOTOR
OPERATED
MODEL, MODIFY OR MODULE
MODIFIED BITUMEN
MONITOR
MOP RACK
MOISTURE RESISTANT
MACHINE SCREW OR MOP SINK
MOUNTED
MOUNTING
METAL
MULLION
MICROWAVE
MEMBRANE WATERPROOFING
RCVT
RLG
RS
RT
RV
RVS
RFI
RFP
RECEIVER
RAILING
ROUGH OPENING
RIGHT
ROOF VENT
REVERSE
REQUEST FOR INFORMATION
REQUEST FOR PROPOSAL
STUD WIDTH PARTITION WIDTHPARTITION TYPE DESIGNATION = 'X'
NON-RATED PARTITION = N
ACOUSTICAL RATED PARTITION = A
SHAFT PARTITION = S
FURRED PARTITION = F
REFER TO PARTITION DETAIL FOR COMPLETE LEGEND & FURTHER INFORMATION.
#X#
PARTITION
TYPE
STUD WIDTH
FIRE RATING
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE DIETETICS &
CATH LAB FLOORING
SO/KB
GI-002
ABBREVIATIONS & SYMBOLS
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
ABBREVIATIONS
EXPANSION JOINT
EXPANSION JOINT
NORTH
ACCESS PANEL
L A N D I N G
R A M P
L A N D I N G R A M P R A M P
L A N D I N G
ACCESS PANEL
ROOF-10
GUTTER &
DOWNSPOUT
ROOF BELOW
TUBULAR SKYLIGHTS
C2CD01
CS1D4
C2CD02
C2CD11
C2CD09
C2CD08
DS1D3
D2CD01
D2XD01
D2C202
D2CD04
D2CD03
C2XD01
CS2D2
C2CD06
C2CD07
CDC05
CS5D1
GS1D3
G2XD01
HS1D5
H2CD02
HS1D6
GS3D1
GS2D2
DS2D1
H2CD01
G2CD03
BS2D4
B2XD01
D2CD
B1XDO3
OPEN TO BELOW
E Q U
IP
SHELFSHELF
SHELF SHELF
SHELFSHELF
SHELFSHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF
SHELF SHELF
SHELFSHELF
SHELF SHELF
SHELFSHELF
S H E
LFSHELF
SHELFSHELF
SHELF SHELF SHELF
SHELF SHELF SHELF
LOCKERS
SHELF SHELF
SHELF
S H E
LF
SHELF SHELF
SHELF
SHELF
FDS
S H E
LF
S H E
LF
S H E
LF
SHELFSHELFSHELF
FEC
FEC
S H E
LF
S H E
LF
S H E
LF
FEC
FEC
FEC
FE
C
FEC
FEC
FEC FECFEC
F E C
F E C
FEC
UP
DN
DN
DN
DN
DN
DN
DN
UP UP
AE-202
AE-202
CATH LAB
DIETETICS
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE DIETETICS &
CATH LAB FLOORING
SO/AA
GI-003
OVERALL REFERENCE PLANS
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
Rev. Date Description
08.02.2022 100% Issue for Bid
1" = 30'-0"
2nd Floor Reference Plan
F E C
FEC
GI-102
GI-102
CATH
EQUIPMENT
CARDINAL HEALTH
FILE CABINET
OMNICELL
MEDICATION CABINETS
HELMER
MEDICATION REF
(UNDER WIRE RACK)
ROLLING
METAL TABLE
ROLLING METAL TABLES
GI-102
GI-102
GI-102
GI-102
REF
MICROWAVE
FILE
CABINET
STORAGE
CABINET
DRAWERS
COMPUTER
ON WHEELS
SHREDDER
COPIER
SHREDDER
FILE DRAWER
STORAGE
CABINET
COPIER
CONFERENCE
TABLE
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE DIETETICS &
CATH LAB FLOORING
SO/AA
GI-102
2nd FLOOR PHOTO REFERENCE PLAN
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
1/4" = 1'-0"
2nd Floor Cath Lab Photo Reference Plan 1/4" = 1'-0"
2nd Floor Dietetics Photo Reference Plan
G2559 - Cardiac Cath Lab
C2559B - Cardiac Cath Lab Support Spaces
C2331 - Office
C2332 - Office
C2335 - Staff Lounge (Used as Office)
C2337 - Office (Used as Staff Lounge)
C
FEC
174 SF
Chief Nutrition and Food Service
C2333
198 SF
Office C2331
261 SF
Staff Lounge (Used as Office) C2335
289 SF
Office (Used as Staff Lounge) C2337
75 SF
Office C2335A
65 SF
Electrical C2337-2
10 SF
Fire Closet C2331A
333 SF
Corridor C108
177 SF
Office C2332
1084 SF
Dishwashing Area
C2334
REF
MICROWAVE
FILE
CABINET
STORAGE
CABINET
DRAWERS
COMPUTER
ON WHEELS
SHREDDER
COPIER
SHREDDER
FILE DRAWER
STORAGE
CABINET
COPIER
CONFERENCE
TABLE
101 107
101 107
101 107
101 107
101 107
101 107
118 SF
Restroom Men
G2551
117 SF
Restroom Women
621 SF
Cardiac Cath Lab
G2559
221 SF
Cardiac Cath Support Spaces G2559B
154 SF
Cardiac Cath System
Component Room
G2559A
55 SF
Unisex Toilet G2539
114 SF
Cardiac Cath Patient
Consultation G2541
60 SF
EMG
Dressing G2543
704 SF
Corridor G2C09
86 SF
Electrical
ID171
28 SF
Tel
ID170
45 SF
Storage G2604
OMNICELL
MEDICATION CABINETS
ROLLING
METAL TABLE
ROLLING METAL TABLES
101 109
101 110
114 114
2nd FLOOR - DIETETICS
2nd FLOOR - CATH LAB
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE DIETETICS &
CATH LAB FLOORING
SO/AA
AD-202
2nd FLOOR DEMO / EQUIPMENT LIST
(DIETETICS & CATH LAB)
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
1/4" = 1'-0"
2nd Floor - Dietetics FFE Plan 1/4" = 1'-0"
2nd Floor - Cath Lab FFE Plan
Rev. Date Description
08.02.2022 100% Issue for Bid
Key Notes
101 GENERAL NOTE: REMOVE ALL EXISTING FLOORING &
ASSOCIATED WALL BASE IN AREA NOTED.
105 EXISTING EQUIPMENT TO BE DISCONNECTED FROM
UTILITIES, REMOVED & STORED FOR REINSTALLATION.
106 EXISTING CATH IMAGING EQUIPMENT TO REMAIN;
PROTECT IN PLACE.
107 EXISTING FURNISHINGS TO BE REMOVED BY VA.
109 EXISTING EQUIPMENT/CARTS TO BE REMOVED BY VA
STAFF.
110 GENERAL NOTE: ALL EXISTING VA EQUIPMENT TO BE
REMOVED & STORED BY CONTRACTOR SHALL BE
SECURED TO ACCEPTANCE OF VA CONTRACTING
OFFICER or THEIR REPRESENTATIVE, PHOTO DOCUMENT
AND LOG. PRIOR TO RE-INSTALLATION OF EQUIPMENT,
CONTRACTOR SHALL SCRUB CLEAN ALL EQUIPMENT
UNITS PER THEIR RESPECTIVE MANUFACTURER
SPECIFICATIONS.
114 EXISTING OMNICELL UNIT TO BE DISCONNECTED FROM
UTILITIES, REMOVED & STORED FOR REINSTALLATION.
115 EXISTING REFRIGERATOR TO BE DISCONNECTED FROM
UTILITIES, REMOVED & STORED FOR REINSTALLATION.
116 EXISTING MEDICAL SUPPLY STORAGE CABINETS TO BE
REMOVED & STORED FOR REINSTALLATION.
117 EXISTING WIRE RACK SHELVING TO BE REMOVED &
STORED FOR REINSTALLATION.
KEY PLAN
1 Coat Rack
1 Chair
9 Office Chairs
1 Refrigerator
1 Microwave
4 Computers
1 Conference Table
3 Desks
1 Locker Unit
C2337 Staff Lounge
3 Work Cubicles
1 Drawers
1 Tall Storage Cabinet
4 Computers (One with 2 monitors)
1 Metal File Drawer
1 Shredder
1 Copier
Stack of Chairs
4 Rolling Laptop
1 Work Cubicle
3 Desks
C2335 Office
1 Corner Desk
3 Computers (2 monitors each)
3 Office Chairs
1 Storage Cabinet
1 File Drawer
1 Shredder
1 Copier
3 Work Cubicles (one with drawers)
C2332 Office
1 Corner Desk
3 Computers (2 monitors each)
1 File CabinetC2331 Office
3 Corner Desks
Room Number Room Name Qty Equipment
Dietetics Equipment List
1 Rolling table
1 Helmer Medication refrigerator
3 Cardinal Health Storage HF154163 G2559B
Cardiac Cath
Support Spaces
5 Omnicell Storage
3 Rolling desks G2559 Cardiac Cath Lab
1 Philips - Azurion
Room Number Room Name Qty Equipment
Cath Lab Equipment List
C
FEC
PARTITION LEGEND:
NOTE:
-CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE COMMENCEMENT
OF WORK.
-DIMENSIONS: WALL DIMENSIONS ARE FACE OF FINISHED FACE TO
FINISHED FACE UNLESS NOTED OTHERWISE. WINDOW / DOOR
DIMENSIONS ARE TO CENTER LINE OF WINDOW / DOOR.
-ALL MTL. STUDS ARE 4" U.N.O. (MATCH FRAMING OF CURRENT
CONDITIONS AS APPLICABLE)
-WHERE DIMENSION IS PRECEEDED BY A (±) SYMBOL, THIS
REPRESENTS/ALLOWS A "FLOAT" IN LAYING OUT THE WORK.
CONTRACTOR IS TO NOTIFY ARCHITECT IN WRITING, PRIOR TO FRAMING,
IF DIMENSION EXCEED ±2" FOR DIRECTION ON HOW TO PROCEED.
(E) 1-HOUR RATED FIRE PARTITION
(E) ACOUSTICAL / NON-RATED PARTITION
(E) PARTITION TO BE DEMOLISHED
(E) 2-HOUR RATED FIRE BARRIER
201 204 206
3’−0" 3’−0"
201 204 206
621 SF
Cardiac Cath Lab
G2559
221 SF
Cardiac Cath Support Spaces G2559B
LVT-1
LVT-1 LVT-1
LVT-1 LVT-1
LVT-1
201 204 206
201 204 206
201 204 206 201 204 206
201 204 206
201 204 206
174 SF
Chief Nutrition &
Food Service C2333
75 SF
Office C2335A
261 SF
Staff Lounge (Used as Office) C2335
289 SF
Office (Used as Staff Lounge) C2337
198 SF
Office C2331
177 SF
Office C2332
2nd FLOOR - DIETETICS
2nd FLOOR - CATH LAB
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE DIETETICS &
CATH LAB FLOORING
SO/AA
AE-202
2nd FLOOR RENOVATION PLAN
(DIETETICS & CATH LAB)
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
Key Notes
201 INSTALL NEW FLOORING & INTEGRAL COVED WALL BASE
(REFER TO FINISH SCHEDULE & DETAILS).
204 GENERAL NOTE: EQUIPMENT/CARTS & FURNISHINGS
REMOVED BY VA STAFF WILL BE REPLACED BY VA STAFF
AFTER CONSTRUCTION COMPLETION.
206 GENERAL NOTE: PATCH & PAINT WALLS WHERE DAMAGED
DURING CONSTRUCTION ACTIVITIES (MATCH EXISTING
FINISHES).
KEY PLAN
1/4" = 1'-0"
2nd Floor - Cath Lab 1/4" = 1'-0"
2nd Floor - Dietetics
Rev. Date Description
08.02.2022 100% Issue for Bid
WSF-1
WSF-2
WSF-1
FLOORING:
LVT-1 LINEAR VINYL TILE
MANUFACTURER: SHAW CONTRACT
COLLECTION: TERRAIN II
SIZE : 20 MIL, 6X48
COLOR: 00774 "NEST"
WSF-1 WELDED SEAM VINYL SHEET FLOORING
MANUFACTURER: SHAW CONTRACT
COLLECTION: VITALITY 0873V
COLOR: 73755 "COMFORT"
REMARKS: 6" COVED BASE AS NEEDED
WSF-2 WELDED SEAM VINYL SHEET FLOORING
MANUFACTURER: SHAW CONTRACT
COLLECTION: VITALITY 0873V
COLOR: 73120 "UPLIFT"
REMARKS: 6" COVED BASE AS NEEDED
FINISH LEGEND:
BASE:
RB-1 RUBBER BASE
MANUFACTURER: FLEXCO
COLOR: DARK BEIGE #37
SIZE: 6"
FINISH SCHEDULE GENERAL NOTES:
1. ALL MATERIALS TO BE INSTALLED PER MANUFACTURE'S INSTRUCTIONS.
2. USE WATER-BASED EPOXY PAINT w/ SEMI-GLOSS FINISH AT TOILET ROOMS, SUB-STERILE CORE, PROCEDURE ROOMS, SOILED/CLEAN/UTILITY WORK ROOMS.
3. ALL INTEGRAL FLASH COVE BASES TO BE 4" HIGH & SUPPORTED BY A COVE SUPPORT STRIP. FINISH TOP OF COVE w/ ALUMINUM TRIM (SEAL ALL JOINTS TO WALL
SUBSTRATE). NOTED AS BASE TYPE SVB-#.
4. PROVIDE MATCHING WELD ROD AT ALL SHEET VINYL SEAMS.
5. PROVIDE BEVELED TRANSITION STRIPS AT FLOOR MATERIAL CHANGES SO THAT THE VERTICAL DIFFERENCE IN ELEVATION IS NOT GREATER THAN 1/2". FLOAT SUBSTRATE AS
NEEDED WHEN APPLICABLE.
6. MANUFACTURER’S TRADE NAMES AND NUMBERS USED HEREIN ARE ONLY TO IDENTIFY COLORS, FINISHES, TEXTURES AND PATTERNS. PRODUCTS OF OTHER MANUFACTURER’S EQUIVALENT TO COLORS, FINISHES, TEXTURES AND PATTERNS OF MANUFACTURERS LISTED THAT MEET REQUIREMENTS OF TECHNICAL SPECIFICATIONS WILL BE ACCEPTABLE UPON APPROVAL IN WRITING BY THE CONTRACTING OFFICER'S REPRESENTATIVE (COR) FOR FINISH REQUIREMENTS.
SHEET VINYL COVE BASE
WELDED SEAM
FLOORING PER
SCHEDULE
PRE-FORMED COVE STRIP
(1-1/4" RADIUS MIN.)
ALUMN. COVE CAP
1/8" RESILIENT FLOORING
ADAPTOR
1/8" RESILIENT FLOORING
TYPES OF RESILIENT
FLOORING TO INCLUDE:
- VCT
- SHEET VINYL
- STATIC DISSIPATIVE TILE
- EPOXY FLOORING
1/8" RESILIENT FLOORING (VCT,
SHEET VINYL, STATIC
DISSIPATIVE TILE, EPOXY
FLOORING)
VINYL REDUCER - JOHNSONITE
SSR-XX-B, BINDER BAR EDGING
FOR 1/16" TO 1/8" RESILIENT
FLOORING. COLOR: T.B.D.
CONCRETE
TAPE &
FINISH
CUT GYPSUM BOARD PATCH
TO FIT SNUG INTO OPENING
(TEXTURE & PAINT TO MATCH
ADJACENT)
SEALANT PER SCHEDULE
(E) PARTITION
/4
M
IN
1-1/4" TYPE S SCREWS @
8" O.C. MAX.
SECTION VIEW
(E) BOTTOM TRACK
Building Number
Drawing NumberLocation:
PhaseDrawing Title
Approved:
Issue Date Checked Drawn
StampARCHITECT / ENGINEER OF RECORDCONSULTANT
VA FORM 08 - 6231
Revisions:
MA Architects, Inc.
385 Van Ness Ave., Suite 110, Torrance, CA 90501 www.ma-architects.net
Planning - Architecture - Interiors
Project Number
Bldg 1 and 1D
Project Title
REPLACE DIETETICS &
CATH LAB FLOORING
SO/AA
AE-900
ROOM FINISH SCHEDULE & DETAILS
VA Project Number
654-22-003
SMc
VA Sierra Nevada Healthcare System 975 Kirman Avenue, Reno, NV 89502
08.02.2022
100% Contract Documents Issue for Bid
FULLY
SPRINKLERED
2165B
FINISH SCHEDULE (EXISTING)
Room
Number Room Name Area Existing Floor Existing Base
CARDIAC CATH LAB
G2559 Cardiac Cath Lab 621 WSF WSF
G2559B Cardiac Cath Support Spaces 221 WSF WSF
DIETETICS
C2333 Chief Nutrition & Food Service 174 CPT RB
C2331 Office 198 CPT RB
C2335 Staff Lounge (Used as Office) 261 CPT RB
C2335A Office 75 CPT RB
C2337 Office (Used as Staff Lounge) 289 CPT RB
C2332 Office 177 CPT RB
FINISH SCHEDULE (RENOVATION)
Room
Number Room Name Area (N) Floor (N) Base
CARDIAC CATH LAB
G2559 Cardiac Cath Lab 621 WSF-1/WSF-2 WSF-1
G2559B Cardiac Cath Support Spaces 221 WSF-1 WSF-1
DIETETICS
C2333 Chief Nutrition & Food Service 174 LVT-1 RB-1
C2331 Office 198 LVT-1 RB-1
C2335 Staff Lounge (Used as Office) 261 LVT-1 RB-1
C2335A Office 75 LVT-1 RB-1
C2337 Office (Used as Staff Lounge) 289 LVT-1 RB-1
C2332 Office 177 LVT-1 RB-1
3" = 1'-0"
2 TYP. SHEET VINYL COVING
6" = 1'-0"
RESILIENT TO RESILIENT TRANSITION
12" = 1'-0"
4 RESILIENT FLOORING TO CONC.
3" = 1'-0"
3 GYP. BRD. PATCH @ BASE
| GI-000 - COVER SHEET |
| GI-001 - GENERAL NOTES AND STANDARDS |
| GI-002 - ABBREVIATIONS & SYMBOLS |
| GI-003 - OVERALL REFERENCE PLANS |
| GI-010 - PROJECT PHASING (3rd FLOOR) |
| GI-102 - 2nd FLOOR PHOTO REFERENCE PLAN |
| GI-103 - 3rd FLOOR REFERENCE PLAN |
| GI-103A - 3rd FLOOR PHOTOS |
| AD-202 - 2nd FLOOR DEMO / EQUIPMENT LIST (DIETETICS & CATH LAB) |
| AD-203 - 3rd FLOOR DEMO / EQUIPMENT LIST (OR SUITES) |
| AE-202 - 2nd FLOOR RENOVATION PLAN (DIETETICS & CATH LAB) |
| AE-203 - 3rd FLOOR RENOVATION PLAN (OR SUITES) |
| AE-203A - 3rd FLOOR OR SUITES FLOORING PATTERNS |
| AE-900 - ROOM FINISH SCHEDULE & DETAILS |
File details come from the government source that posted it. Updated .