This document is an attachment to a state and local contract opportunity for Bloomingdale Elementary School. The scope of work includes interior painting, exterior painting, and exterior wall repair and replacement. The project overview states the work is to be completed over the summer months. Bidders must attend a mandatory pre-bid conference on May 1, 2023, and bids are due on May 15, 2023. The contract will be awarded on June 1, 2023, with work to be completed by August 15, 2023. The contract term is for one year with the option to renew for up to two additional one-year terms.

Pricing must be provided on a lump sum basis. No set-asides or minority/women-owned business requirements are specified. The current incumbent contractor is ABC Painting, Inc. Funding for the project is provided through the state's school improvement budget. The total estimated project cost is $350,000.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VOLUME OF FINAL/BID SET

JAMES W. BUCKLEY AND ASSOCIATES INC. -- ARCHITECTS

W

AR

NI

NG

: C on tra cto rs, su bc on tra cto rs, ve nd or s a nd su pp lie rs ar e a dv ise d t ha t th e c on tra ct do cu me nts co ns ist of

Ar ch ite ct-re pr od uc ed pr int ed

, b ou nd an d n um be re d s pe cif ica tio ns

, A rch ite ct-re pr od uc ed pr int ed

, b ou nd an d nu mb er ed bl ue

- o r b lac k-l ine pr int s, ad de nd a, po st-bid ad de nd a, an d c ha ng e o rd er s o nly . D oc um en ts re pr od uc ed by pa rtie s o the r t ha n t he A rch ite ct, w he the r in ha rd co py or in el ec tro nic fo rm at, sh all no t b e c on sid er ed pa rt the co ntr ac t d oc um en ts an d d o n ot su pe rse de th e p ro vis ion s o f th e c on tra ct do cu me nts . T he co ntr ac tor su bc on tra cto rs, ve nd or s a nd su pp lie rs ar e s ole ly re sp on sib le for ve rifi ca tio n t ha t in for ma tio n u tili ze d i n b idd ing de ve lop me nt of sh op dr aw ing s, an d c on str uc tio n o f th e f ac ilit y a re id en tic al to the co ntr ac t d oc um en ts.

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

SET NUMBER:

Copyright (c) 2019 All Rights Reserved.

ISSUED FOR:

NOT VALID UNLESS SIGNED

JA

M

ES

W . B U C K

LE

Y A

SS

O C

IA

TE

S

IN

C

- A

RC

H

IT

EC

TS

G

EO

RG

IA

7 East Congress Street, Suite 800 Savannah, Georgia 31401 Phone: (912) 447-1080 Fax: (912) 447-1060

Email: mail@jwbuckley.com

2 2

SW

A

IN

SB

O

RO

, A

LB

A N Y, R O M E, A N D S A V A N N A H

9/1 2/2

3 2

:56 :03

P M

C:

\U se rs\ mm \D oc um en ts\

-0

_C

EN

TR

AL

_2

3-

-3

0_ R2

3_ mm

C3 W

PH

.rv t

BLOOMINGDALE ELEMENTARY SCHOOL

SAVANNAH-CHATHAM COUNTY PUBLIC SCHOOL SYSTEM

BLOOMINGDALE, GEORGIA SCHOOL CODE: 625-4052

BLOOMINGDALE ELEMENTARY

SCHOOL

SAVANNAH-CHATHAM COUNTY PUBLIC SCHOOL SYSTEM

BLOOMINGDALE, GEORGIA SCHOOL CODE: 625-4052

C O

VE

R

S H

EE

T

- V O

LU

M

E

BL

O

O M

IN

G

D

AL

E

EL

EM

EN

TA

R

Y

SC

H O

O L

09/13/2023

22-072

CRB

HGB

HGB

FINAL/BID

SA

VA

N N

AH

-C

H

AT

H

AM

C O

U N

TY

P

U

BL

IC

S

C H

O O

L

SY

ST

EM

BL

O

O M

IN

G

D

AL

E, G

EO

R

G

IA

SC

H O

O L

C O

D E:

-4

James W. Buckley and Associates Inc.

114 North Green Street Swainsboro, Georgia 30401 Phone: (478) 237-6467 Fax: (478) 237-3197 Email: civil@jwbuckley.com

CIVIL ENGINEER:

Saussy Engineering 400 E Johnny Mercer Boulevard Savannah, Georgia 31410 Phone: (912) 898-8255 Fax: (912) 898-1882 Email: whsdrawings@saussyengineering.com

STRUCTURAL ENGINEER:

Method Engineering Group 2 East Bryan Street, Suite 1500C Savannah, GA 31401 Phone: (912) 963 - 1611 Email: amckeever@methodeg.com

MECHANICAL ENGINEER:

Electrical Design Consultants, Inc.

1201 Broad Street, Suite 1A Augusta, Georgia 30901 Phone: (706) 724-3551 Fax: (706) 724-8507 Email: drawings@edcaugusta.com

ELECTRICAL ENGINEER:

SQUARE FOOTAGE TABULATION

SQUARE FOOTAGES SHOWN ARE APPROXIMATE.

DO NOT USE SQUARE FOOTAGES FOR BIDDING.

TOTAL GROSS SQUARE FOOTAGE

OTHER CANOPIES

BUS CANOPY

FRONT ENTRANCE

GROSS BUILDING SQUARE FOOTAGE

SQ. FT. GROSS x 1/2 =

SQ. FT.

SQ. FT.

SQ. FT.

SQ. FT.

SQ. FT.

OTHER COVERED ENTRANCES SQ. FT.SQ. FT. GROSS x 1/2 =

SQ. FT. GROSS x 1/2 =

SQ. FT. GROSS x 1/2 =

157036

150879

10509

GRADES:

MEMBERSHIP:

FUNDING:

SQ. FEET RENOVATION:

SQ. FEET NEW:

SQ. FEET TOTAL: 150879

K-5

STATE/LOCAL

150879

CONCRETE BRICK

C.M.U.

(SECTION/ DETAIL)

C.M.U.

(PLAN)

PLYWOOD

INSULATION,

BATT

INSULATION,

RIGID

INSULATION,

BLOWN-IN

CEMENTITIOUS

WOOD FIBER

STEEL

ALUMINUM

ORNAMENTAL

METAL

CONCRETE, PRE-CAST

(WHEN INDICATED

GRAPHICALLY)

CONCRETE,

LIGHT-WEIGHT

CONCRETE

(ELEVATION)

MATERIALS LEGEND

FINISH WOOD

WOOD BLOCKING

SOLID SURFACING

MARBLE

TERRAZZO

GYP. BD.

COMPACTED EARTH

FILL

NOTE: SOME MATERIALS SHOWN HERE MAY NOT OCCUR IN THIS PROJET

ROOM NAME

A1.10

DOOR NUMBER

- FRAME TYPE

ROOM NAME

ROOM NUMBER

SHEET ON WHICH

SECTION/DETAIL

IS DRAWN

SECTION/DETAIL

NUMBER

A1.0

REFERENCE SYMBOLS & TAGS

A1.1

SCHEDULED

EQUIPMENT

W0 WALL TYPE

A4.1 1

CALLOUT

NUMBER

SHEET ON WHICH

CALLOUT IS DRAWN

A9.4 1

ELEVATION NUMBER

SHEET ON WHICH

ELEVATION IS DRAWN

OR

1-A1.10

1 KEYED NOTE

ELEVATION NUMBER

SHEET ON WHICH

ELEVATION IS DRAWN

OR

OR

1- A4

.1 1-

A9 .4

2S

T

D

INTERIOR ELEVATIONS

EXTERIOR ELEVATIONS

DETAIL CALLOUTS

SECTIONS / DETAILS

OR

OR

OR

OR

ONE HOUR RATED

WALL

TWO HOUR RATED

WALL

THREE HOUR RATED

WALL

NON-RATED WALL,

EXTEND TO DECK &

SEALED

SMOKE TIGHT

PARTITION

TWO HOUR SMOKE

BARRIER PARTITION

PARTIAL HEIGHT

WALL

0 GRID LINE

ELEVATION DATUM

NOTE: ALL ELEVATIONS ARE

FROM PRIMARY BUILDING FIN.

FLOOR UNLESS OTHERWISE

NOTED

VOLUME OF FINAL/BID SET

W

AR

NI

NG

: C on tra cto rs, su bc on tra cto rs, ve nd or s a nd su pp lie rs ar e a dv ise d t ha t th e c on tra ct do cu me nts co ns ist

Ar ch ite ct-re pr od uc ed pr int ed

, b ou nd an d n um be re d s pe cif ica tio ns

, A rch ite ct-re pr od uc ed pr int ed

, b ou nd an d nu mb er ed bl ue

- o r b lac k-l ine pr int s, ad de nd a, po st-bid ad de nd a, an d c ha ng e o rd er s o nly . D oc um en ts re pr od uc ed rtie s o the r t ha n t he A rch ite ct, w he the r in ha rd co py or in el ec tro nic fo rm at, sh all no t b e c on sid er ed pa rt the co ntr ac t d oc um en ts an d d o n ot su pe rse de th e p ro vis ion s o f th e c on tra ct do cu me nts . T he co ntr ac tor su bc on tra cto rs, ve nd or s a nd su pp lie rs ar e s ole ly re sp on sib le for ve rifi ca tio n t ha t in for ma tio n u tili ze d i n b idd ing de ve lop me nt of sh op dr aw ing s, an d c on str uc tio n o f th e f ac ilit y a re id en tic al to the co ntr ac t d oc um en ts.

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

SET NUMBER:

Copyright (c) 2019 All Rights Reserved.

ISSUED FOR:

NOT VALID UNLESS SIGNED

JA

M

ES

W . B U C K

LE

Y A

SS

O C

IA

TE

S

IN

C

- A

RC

H

IT

EC

TS

G

EO

RG

IA

2 2

SW

A

IN

SB

O

RO

, A

LB

A N Y, R O M E, A N D S A V A N N A H

/4/

5:

:26 P

M C:

\U se rs\ jrw

\D oc um en ts\

-0

_C

EN

TR

AL

_2

3-

-1 2_

R2 3_ jrw _.r vt

BLOOMINGDALE ELEMENTARY

SCHOOL

SAVANNAH-CHATHAM COUNTY PUBLIC SCHOOL SYSTEM

BLOOMINGDALE, GEORGIA SCHOOL CODE: 625-4052

IN

D

EX

VO

LU

M E

BL

O

O M

IN

G

D

AL

E

EL

EM

EN

TA

R

Y

SC

H O

O L

09/13/2023

22-072

CRB

HGB

TDP

FINAL/BID

SA

VA

N N

AH

-C

H

AT

H

AM

C O

U N

TY

P

U

BL

IC

S

C H

O O

L

SY

ST

EM

BL

O

O M

IN

G

D

AL

E, G

EO

R

G

IA

SC

H O

O L

C O

D E:

-4

GENERAL NOTES

A.

1.

2.

B.

1.

C.

1.

D.

1.

E.

1.

2.

3.

4.

5.

F.

1.

2.

THE FOLLOWING NOTES SUPPLEMENT AND ADD TO THE DRAWINGS AND SPECIFICATIONS. IF THERE IS ANY CONFLICT, AMBIGUITY, ETC., CREATED BY ANY NOTE, THE CONTRACTOR SHALL COMPLY WITH THE MORE STRINGENT REQUIREMENT.

DIMENSIONS:

THE GENERAL CONTRACTOR, SUBCONTRACTORS AND ALL EMPLOYEES ON THIS PROJECT ARE NOT ALLOWED TO SCALE DRAWINGS TO DETERMINE DISTANCES NOT DIMENSIONED. IF FURTHER DIMENSIONING IS REQUIRED, THE CONTRACTOR SHALL REQUEST IN WRITING FOR WRITTEN CLARIFICATION BY THE ARCHITECT. ALL DIMENSIONS

ARE GIVEN TO FACE OF CMU, FACE OF BRICK, OR FACE OF STUD UNLESS NOTED OTHERWISE.

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, GRADE PITCHES AND OTHER CONDITIONS BY TAKING MEASUREMENTS PRIOR TO ORDERING MATERIALS OR DOING WORK. REFER DISCREPANCIES TO THE ARCHITECT FOR ADDITIONAL INSTRUCTIONS. THE CONTRACTOR IS RESPONSIBLE FOR MEASUREMENTS. NO CONSIDERATION WILL BE GIVEN TO ANY CLAIM BASED ON DIFFERENCES BETWEEN DRAWINGS OR SPECIFICATIONS AND ACTUAL

MEASUREMENTS.

SIMILAR CONDITIONS:

WHERE A DETAIL OR SECTION IS SHOWN FOR ONE CONDITION, IT APPLIES TO ALL LIKE OR SIMILAR CONDITIONS.

COORDINATION:

COORDINATING ROUTING OF THE CONTRACTOR'S WORK WITH OTHER TRADES IS ESSENTIAL, AND ANY EXPENSE

REQUIRED FOR REMOVAL OR RELOCATION SHALL BE BORNE BY THE CONTRACTOR.

SITE WORK:

PRIOR TO CLEARING AND GRUBBING, PROVIDE SURFACE SITE DEWATERING BY TEMPORARY DITCHING, SUMPING, OR OTHER APPROVED METHODS. RETAIN AND MAINTAIN TEMPORARY METHODS UNTIL PERMANENY DRAINAGE

SYSTEMS (STORM DRAINS, SWALES, ETC.) ARE INSTALLED.

CONCRETE BLOCK:

BULL NOSE CONCRETE BLOCK SHALL BE USED AT ALL EXPOSED (OUTSIDE) CORNERS AT WALLS AND PARTITIONS

INSIDE BUILDING INCLUDING WINDOW AND DOOR JAMB CONDITIONS.

WHERE CONCRETE BLOCK IS EXPOSED AT INTERIOR WALLS, PROVIDE SHALLOW CONCAVE CONCRETE BLOCK

JOINTS IN KITCHENS AND ALL TOILET ROOMS.

CONTRACTOR SHALL PROVIDE MASONRY WALLS TO MEET ALL REQUIREMENTS OF FINISH INSTALLER.

MANUFACTURER SHALL ENSURE THAT ALL MATERIAL AND INSTALLATION WARRANTIES REMAIN EFFECTIVE.

JOINT REINFORCING MAY BE OMITTED IN DETAILING FOR CLARITY; INSTALL IN MASONRY JOINTS AT DESIGNATED

INTERVALS WHETHER SHOWN OR NOT.

IN ROOMS WITH EXPOSED STRUCTURAL CEILING, EXTEND WALLS TO ROOF OR FLOOR DECK ABOVE.

FLASHING:

OVERLAP ALL FLASHING JOINTS 4" MINIMUM AND SEAL WATERTIGHT.

ARCHITECT IS TO OBSERVE ALL FLASHING INSTALLATION PRIOR TO FLASHING BEING COVERED UP BY NEW

CONSTRUCTION.

NORTH

KEY PLAN

STANDARD ABBREVIATIONS

AT@

ANCHOR BOLTA.B.

ABOVE FINISH FLOORA.F.F.

ALTERNATEALT.

ALUMINUMALUM.

ANODIZEDANOD.

ACOUSTICAL TILEA.T.

ASH URNAU

BABY CHANGING

STATION

BCS

BOARDBD.

BETWEENBET.

BLOCKBLK.

BULLNOSEB.N.

BEAMBM.

BOTTOMBOT.

CHANNEL[

CENTERLINEC/L

CABINETCAB.

CEILINGCLG.

CONCRETE

MASONRY UNIT

C.M.U.

COLUMNCOL.

CONCRETECONC.

CONTINUOUSCONT.

CLASSROOMC.R.

CERAMIC TILEC.T.

CENTERCTR.

DIAMETERDIA.

DOUBLE BULLNOSED.B.N.

DETAILDET.

DRINKING FOUNTAIND.F.

DIMENSIONDIM.

DISPENSERDISP.

EACHEA.

ELECTRIC HAIR DRYEREAD

ELECTRIC HAND DRYEREHD

EXPANSION JOINTE.J.

ELEVATIONELEV.

EQUALEQ.

EXPANSIONEXP.

EXTERIOREXT.

FINISH ALL SIDESF.A.S.

FLOOR DRAINF.D.

PURSE SHELFP.S.

PRESSURE-TREATEDP.T.

PAPER TOWEL

DISPENSER

PTD

PAPER TOWER

DISPENSER/RECEPTACLE

PTDR

QUARRY TILEQ.T.

RADIUSRAD.

ROOF DRAINR.D.

RECEPTACLERECEP.

REINFORCEDREINF.

REQUIREDREQ'D.

ROBE HOOKRH

ROOMRM.

RIGHT-OF-WAYR/W

STORAGE CABINETS.C.

SEAT COVER DISPENSERSCD

SHOWER CURTAIN RODSCR

SOAP DISPENSERSD

SQUARE FOOTS.F.

SIMILARSIM.

SANITARY NAPKIN

DISPENSER

SND

SANITARY NAPKIN

RECEPTACLE

SNR

SQUARE FOOTSQ. FT.

STAINLESS STEELS.S.

SOAP TRAYST

STEELSTL.

STORAGESTOR.

SUSPENDEDSUSP.

TACK BOARDT.B.

TUMBLER/TOOTHBRUS

H HOLDER

TBH

TEACHER'S CABINETT.C.

TEMPEREDTEMP.

TOWEL HOLDERTH

THICKTK.

TOWEL PINTP

TOWEL RODTR

TOILET TISSUE

DISPENSER

TTD

TYPICALTYP.

UNLESS NOTEDU.N.

UTILITY SHELF UNITUSU

WITHW/

WINDOWWIND.

FIRE EXTINGUISHERF.E.

FINISH FLOORF.F.

FINISHFIN.

FLOORFL.

FIRE RATEDF.R.

FOLDING SHOWER SEATFSS

GAUGEGA.

GALVANIZEDGALV.

GRAB BARGB

GLAZE-COATED CMUG.C.C.B.

GYPSUMGYP.

HANDICAPPED-

ACCESSIBLE

H.C.

HOLLOW METALH.M.

HEIGHTHT.

INSULATIONINSUL.

JOINTJT.

LAMINATEDLAM.

LINEAL FEETL.F.

MANUFACTURERMFR.

MAXIMUMMAX.

MOP AND BROOM

HOLDER

MBH

MEDICINE CABINETMC

METALMET.

MINIMUMMIN.

MIRRORMIR.

MISCELLANEOUSMISC.

MASONRY OPENINGM.O.

NOT IN CONTRACTN.I.C.

NOMINALNOM.

NOT TO SCALEN.T.S.

OPPOSITE HANDO.H.

OPPOSITEOPP.

ON CENTERO.C.

OUTSIDE DIAMETERO.D.

PLATEPL.

PAINTED CONCRETE

BLOCK

P.C.B.

PRE-FORMED

EXPANSION JOINT

P.E.J.

PROPERTY LINEP.L.

PLYWOODPLY.

PROJECTIONPROJ.

FOOTFT.

FACIAL TISSUE

DISPENSER

FTD

SHOWER CURTAIN AND

HOOKS

SCH

INDEX OF DRAWINGS

CR

W

IN

G

A

CR

W

IN

G A

CR WING B

CR W

ING C

GYMNASIUM/

SPED

CAFETERIA

MEDIA

ADMIN

CIVIL DRAWINGS

L1.0 OVERALL LANDSCAPE PLAN

L1.1 ENLARGED LANDSCAPE PLAN

L1.2 ENLARGED LANDSCAPE PLAN

L1.3 LANDSCAPE NOTES AND DETAILS

L2.0 OVERALL IRRIGATION PLAN

L2.1 ENLARGED IRRIGATION PLAN

L2.2 ENLARGED IRRIGATION PLAN

L2.3 IRRIGATION NOTES AND DETAILS

ARCHITECTURAL DRAWINGS

A1.0 SITE PLAN

A1.1 COMPOSITE PLAN - FIRST FLOOR

A1.2 COMPOSITE PLAN - SECOND FLOOR

A1.3 LIFE SAFETY PLAN - FIRST FLOOR

A1.4 LIFE SAFETY PLAN - SECOND FLOOR

A1.5 ROOF PLAN

A2.0 1/8" FLOOR PLAN - ADMINISTRATION

A2.1 1/8" FLOOR PLAN - CAFETERIA

A2.2 1/8" FLOOR PLAN - MEDIA CENTER

A2.3 1/8" FLOOR PLAN - GYMNASIUM

A2.4 1/8" FLOOR PLAN - CR WING A - FIRST FLOOR

A2.5 1/8" FLOOR PLAN - CR WING B - FIRST FLOOR

A2.6 1/8" FLOOR PLAN - CR WING C - FIRST FLOOR

A2.7 1/8" FLOOR PLAN - CR WING A - SECOND FLOOR

A2.8 1/8" FLOOR PLAN - CR WING B - SECOND FLOOR

A2.9 1/8" FLOOR PLAN - CR WING C - SECOND FLOOR

A2.10 1/8" REFLECTED CEILING PLAN - ADMINISTRATION

A2.11 1/8" REFLECTED CEILING PLAN - CAFETERIA

A2.12 1/8" REFLECTED CEILING PLAN - MEDIA CENTER

A2.13 1/8" REFLECTED CEILING PLAN - GYMNASIUM

A2.14 1/8" REFLECTED CEILING PLAN - CR WING A - FIRST

FLOOR

A2.15 1/8" REFLECTED CEILING PLAN - CR WING B - FIRST

FLOOR

A2.16 1/8" REFLECTED CEILING PLAN - CR WING C - FIRST

FLOOR

A2.17 1/8" REFLECTED CEILING PLAN - CR WING A - SECOND

FLOOR

A2.18 1/8" REFLECTED CEILING PLAN - CR WING B - SECOND

FLOOR

A2.19 1/8" REFLECTED CEILING PLAN - CR WING C - SECOND

FLOOR

A2.20 1/8" FLOOR PATTERN PLAN -

ADMINISTRATION/CAFETERIA

A2.21 1/8" FLOOR PATTERN PLAN - MEDIA

CENTER/GYMNASIUM

A2.22 1/8" FLOOR PATTERN PLAN - CR WING A - FIRST FLOOR

A2.23 1/8" FLOOR PATTERN PLAN - CR WING B - FIRST FLOOR

A2.24 1/8" FLOOR PATTERN PLAN - CR WING C - FIRST FLOOR

A2.25 1/8" FLOOR PATTERN PLAN - CR WING A - SECOND

FLOOR

A2.26 1/8" FLOOR PATTERN PLAN - CR WING B - SECOND

FLOOR

A2.27 1/8" FLOOR PATTERN PLAN - CR WING C - SECOND

FLOOR

A3.0 ROOM FINISH SCHEDULE

A3.1 DOOR SCHEDULE/DOOR ELEVATIONS

A3.2 DOOR SILL DETAILS

A3.4 HOLLOW METAL & METAL COILING FRAMES AND

DETAILS

A3.5 HOLLOW METAL & METAL COILING FRAMES AND

DETAILS

A3.6 CURTAINWALL FRAMES AND DETAILS

A3.7 CURTAINWALL FRAME DETAILS

A3.8 ALUMINUM STOREFRONT FRAMES AND DETAILS

ARCHITECTURAL DRAWINGS

A4.0 COMPOSITE EXTERIOR ELEVATIONS

A4.1 EXTERIOR ELEVATIONS

A4.2 EXTERIOR ELEVATIONS

A4.3 EXTERIOR ELEVATIONS

A4.4 EXTERIOR ELEVATIONS

A4.5 EXTERIOR ELEVATIONS

A5.0 BUILDING SECTIONS- ADMIN

A5.1 BUILDING SECTIONS - MEDIA CENTER

A5.2 BUILDING SECTIONS - CAFETERIA

A5.3 BUILDING SECTIONS- KITCHEN

A5.4 BUILDING SECTIONS - GYMNASIUM

A5.5 BUILDING SECTIONS - TYPICAL CR WING

A6.0 WALL SECTIONS - TYPICAL CLASSROOM WING

A6.1 WALL SECTIONS - TYPICAL CLASSROOM WING

A6.2 WALL SECTIONS - TYPICAL CLASSROOM WING

A6.3 WALL SECTIONS - TYPICAL CLASSROOM WING

A6.4 WALL SECTIONS - TYPICAL CLASSROOM WING

A6.5 WALL SECTIONS - ENTRY

A6.6 WALL SECTIONS - ENTRY

A6.7 WALL SECTIONS - ENTRY

A6.8 WALL SECTIONS - ADMIN

A6.9 WALL SECTIONS - MEDIA CENTER

A6.10 WALL SECTIONS - CAFETERIA

A6.11 WALL SECTIONS - CAFETERIA

A6.12 WALL SECTIONS - GYM

A6.13 WALL SECTIONS - GYM

A6.14 WALL SECTIONS - GYM

A6.15 WALL SECTIONS - GYM

A6.16 WALL SECTIONS - CORRIDOR

A6.17 WALL SECTIONS - CORRIDOR

A6.18 WALL SECTIONS - RAMPS AND STEPS

A6.19 WALL SECTIONS - MONUMENTAL STAIR

A6.20 WALL SECTIONS - MONUMENTAL STAIR

A6.21 WALL SECTIONS - MONUMENTAL STAIR

A8.0 WALL TYPES

A8.1 ENLARGED FLOOR PLAN - ADMINISTRATION

A8.2 ENLARGED FLOOR PLAN - MEDIA CENTER

A8.3 ENLARGED FLOOR PLAN - FRONT ENTRY

A8.4 ENLARGED FLOOR PLAN - CAFETERIA/MUSIC

A8.5 ENLARGED FLOOR PLAN - KITCHEN

A8.6 ENLARGED FLOOR PLANS - COURTYARD & SERVICE

YARD

A8.7 ENLARGED FLOOR PLAN - GYMNASIUM

A8.8 ENLARGED PLAN - GYMNASIUM CLERESTORY AND

MEZZANINE

A8.9 ENLARGED FLOOR PLANS

A8.10 ENLARGED FLOOR PLANS

A8.11 ENLARGED FLOOR PLANS

A8.12 ENLARGED FLOOR PLANS - STAIRS

A8.13 ENLARGED FLOOR PLAN - BUS CANOPY

A9.0 MILLWORK PLANS & ELEVATIONS

A9.1 MILLWORK PLANS & ELEVATIONS

A9.2 MILLWORK PLANS & ELEVATIONS

A9.3 MILLWORK SECTIONS - PLASTIC LAMINATE

A9.4 MILLWORK SECTIONS - SOLID SURFACE

A9.5 MILLWORK DETAILS

A9.6 WOODWORKING ELEVATIONS

A9.7 WOODWORKING ELEVATIONS

A9.8 WOODWORKING ELEVATIONS & DETAILS

A10.0 INTERIOR ELEVATIONS

A10.1 INTERIOR ELEVATIONS

A10.2 INTERIOR ELEVATIONS

A10.3 INTERIOR ELEVATIONS

A10.4 INTERIOR ELEVATIONS

STRUCTURAL DRAWINGS

S0.1 STRUCTURAL NOTES

S0.2 WIND PRESSURE SCHEDULES

S1.0 COMPOSITE FOUNDATION PLAN

S1.1 FOUNDATION PLAN - ADMINISTRATION

S1.2 FOUNDATION - PLAN - CAFETERIA

S1.3 FOUNDATION PLAN - MEDIA CENTER

S1.4 FOUNDATION PLAN - GYMNASIUM

S1.5 FOUNDATION PLAN - CLASSROOM WING A

S1.6 FOUNDATION PLAN - CLASSROOM WING B

S1.7 FOUNDATION PLAN - CLASSROOM WING C

S1.8 SECTIONS

S1.9 SECTIONS

S2.0 COMPOSITE SECOND FLOOR FRAMING PLAN

S2.1 SECOND FLOOR FRAMING PLAN - CLASSROOM WING

A

S2.2 SECOND FLOOR FRAMING PLAN - CLASSROOM WING

B

S2.3 SECOND FLOOR FRAMING PLAN- CLASSROOM WING C

S2.4 FLOOR FRAMING SECTIONS

S2.5 FLOOR FRAMING SECTIONS

S3.0 COMPOSITE ROOF FRAMING PLAN

S3.1 ROOF FRAMING PLAN - ADMINISTRATION

S3.2 ROOF FRAMING PLAN - CAFETERIA

S3.3 ROOF FRAMING PLAN - MEDIA CENTER

S3.4 ROOF FRAMING PLAN - GYMNASIUM

S3.5 ROOF FRAMING PLAN - CLASSROOM WING A

S3.6 ROOF FRAMING PLAN - CLASSROOM WING B

S3.7 ROOF FRAMING PLAN - CLASSROOM WING C

S3.8 FLOOR FRAMING SECTIONS

S3.9 FLOOR FRAMING SECTIONS

S4.0 COLUMN AND FOUNDATION SCHEDULE

S4.1 MISCELLANEOUS SCHEDULES

S5.1 TYPICAL DETAILS

S5.2 TYPICAL DETAILS

S5.3 TYPICAL DETAILS

MECHANICAL DRAWINGS

M0.0 HVAC TITLE SHEET

M0.1 HVAC SCHEDULE

M1.0 HVAC COMPOSITE PLAN - FIRST FLOOR

M1.1 HVAC COMPOSITE PLAN - SECOND FLOOR

M1.3 HVAC PLAN - ROOF

M2.0 HVAC PLAN - ADMINISTRATION

M2.1 HVAC PLAN - CAFETERIA

M2.2 HVAC PLAN - MEDIA CENTER

M2.3 HVAC PLAN - GYMNASIUM

M2.4 HVAC PLAN - CR WING A - FIRST FLOOR

M2.5 HVAC PLAN - CR WING B - FIRST FLOOR

M2.6 HVAC PLAN - CR WING C - FIRST FLOOR

M2.7 HVAC PLAN - CR WING A - SECOND FLOOR

M2.8 HVAC PLAN - CR WING B - SECOND FLOOR

M2.9 HVAC PLAN - CR WING C - SECOND FLOOR

M3.0 HVAC PIPING PLAN - ADMINISTRATION

M3.1 HVAC PIPING PLAN - CAFETERIA

M3.2 HVAC PIPING PLAN - MEDIA CENTER

M3.3 HVAC PIPING PLAN -GYMNASIUM

M3.4 HVAC PIPING PLAN - CR WING A - FIRST FLOOR

M3.5 HVAC PIPING PLAN - CR WING B - FIRST FLOOR

M3.6 HVAC PIPING PLAN - CR WING C - FIRST FLOOR

M3.7 HVAC PIPING PLAN - CR WING A - SECOND FLOOR

M3.8 HVAC PIPING PLAN - CR WING B - SECOND FLOOR

M3.9 HVAC PIPING PLAN - CR WING C - SECOND FLOOR

M4.0 HVAC PLAN - ENLARGED KITCHEN PLAN

M4.1 HVAC SECTION VIEWS

M5.0 HVAC DETAILS

M5.1 HVAC DETAILS

M5.2 HVAC DETAILS

M5.3 VRF SCHEMATICS

M5.4 VRF SCHEMATICS

ELECTRICAL DRAWINGS

E1.0 LEGEND, NOTES, DETAILS AND FIXTURE SCHEDULE

E1.1 ELECTRICAL SITE PLAN

E2.0 LIGHTING PLAN - ADMINISTRATION/CAFETERIA

E2.1 LIGHTING PLAN - MEDIA CENTER/GYMNASIUM

E2.2 LIGHTING PLAN - FIRST FLOOR - CR WING A

E2.3 LIGHTING PLAN - FIRST FLOOR - CR WING B

E2.4 LIGHTING PLAN - FIRST FLOOR - CR WING C

E2.5 LIGHTING PLAN - SECOND FLOOR - CR WING A

E2.6 LIGHTING PLAN - SECOND FLOOR - CR WING B

E2.7 LIGHTING PLAN - SECOND FLOOR - CR WING C

E3.0 POWER PLAN - ADMINISTRATION/CAFETERIA

E3.1 POWER PLAN - MEDIA CENTER/GYMNASIUM

E3.2 POWER PLAN - FIRST FLOOR - CR WING A

E3.3 POWER PLAN - FIRST FLOOR - CR WING B

E3.4 POWER PLAN - FIRST FLOOR - CR WING C

E3.5 POWER PLAN - SECOND FLOOR - CR WING A

E3.6 POWER PLAN - SECOND FLOOR - CR WING B

E3.7 POWER PLAN - SECOND FLOOR - CR WING C

E3.8 POWER PLAN - ENLARGED KITCHEN

E4.0 MECHANICAL POWER PLAN - FIRST FLOOR

E4.1 MECHANICAL POWER PLAN - SECOND FLOOR

E4.2 MECHANICAL POWER PLAN - ROOF

E4.3 MECHANICAL CONNECTION SCHEDULES

E5.0 FIRE ALARM SYSTEM PLAN - FIRST FLOOR

E5.1 FIRE ALARM SYSTEM PLAN - SECOND FLOOR

E5.2 SYSTEMS PLAN - FIRST FLOOR

E5.3 SYSTEMS PLAN - SECOND FLOOR

E5.4 ACCESS CONTROLS/CCTV SYSTEMS PLAN - FIRST

FLOOR

E5.5 ACCESS CONTROLS/CCTV SYSTEMS PLAN - SECOND

FLOOR

E5.6 CABLE MANAGEMENT PLAN - FIRST FLOOR

E5.7 CABLE MANAGEMENT PLAN - SECOND FLOOR

E6.0 ELECTRICAL PLAN - ENLARGED TYPICAL CLASSROOM

E7.0 POWER RISER DIAGRAM

E7.1 PANEL SCHEDULES

E7.2 PANEL SCHEDULES

E7.3 PANEL SCHEDULES

E7.4 PANEL SCHEDULES

E8.0 ELECTRICAL DETAILS

E8.1 ELECTRICAL DETAILS

E8.2 ELECTRICAL DETAILS

E8.3 ELECTRICAL DETAILS

E8.4 ELECTRICAL DETAILS

E8.5 ELECTRICAL DETAILS

SQUARE FOOTAGE TABULATION

SQUARE FOOTAGES SHOWN ARE APPROXIMATE.

DO NOT USE SQUARE FOOTAGES FOR BIDDING.

TOTAL GROSS SQUARE FOOTAGE

OTHER CANOPIES

BUS CANOPY

FRONT ENTRANCE

GROSS BUILDING SQUARE FOOTAGE

SQ. FT. GROSS x 1/2 =

SQ. FT.

SQ. FT.

SQ. FT.

SQ. FT.

SQ. FT.

OTHER COVERED ENTRANCES SQ. FT.SQ. FT. GROSS x 1/2 =

SQ. FT. GROSS x 1/2 =

SQ. FT. GROSS x 1/2 =

157036

150879

10509

GRADES:

MEMBERSHIP:

FUNDING:

SQ. FEET RENOVATION:

SQ. FEET NEW:

SQ. FEET TOTAL: 150879

K-5

STATE/LOCAL

150879

VOLUME 1 VOLUME 2

PLUMBING DRAWINGS

P0.0 PLUMBING TITLE SHEET & SCHEDULES

P1.1 PLUMBING COMPOSITE PLAN - FIRST FLOOR

P1.2 PLUMBING COMPOSITE PLAN - SECOND FLOOR

P1.3 PLUMBING ROOF PLAN

P2.0 WASTE AND VENT PLAN - ADMINISTRATION

P2.1 WASTE & VENT PLAN - CAFETERIA

P2.2 WASTE & VENT PLAN - MEDIA CENTER

P2.3 WASTE & VENT PLAN - GYMNASIUM

P2.4 WASTE & VENT PLAN - CR WING A - FIRST FLOOR

P2.5 WASTE & VENT PLAN - CR WING B - FIRST FLOOR

P2.6 WASTE & VENT PLAN - CR WING C - FIRST FLOOR

P2.7 WASTE & VENT PLAN - CR WING A - SECOND FLOOR

P2.8 WASTE & VENT PLAN - CR WING B - SECOND FLOOR

P2.9 WASTE & VENT PLAN - CR WING C - SECOND FLOOR

P3.0 HOT & COLD WATER PLAN - ADMINISTRATION

P3.1 HOT & COLD WATER PLAN - CAFETERIA

P3.2 HOT & COLD WATER PLAN - MEDIA CENTER

P3.3 HOT & COLD WATER PLAN - GYMNASIUM

P3.4 HOT & COLD WATER PLAN - CR WING A - FIRST FLOOR

P3.5 HOT & COLD WATER PLAN - CR WING B - FIRST FLOOR

P3.6 HOT & COLD WATER PLAN - CR WING C - FIRST FLOOR

P3.7 HOT & COLD WATER PLAN - CR WING A - SECOND

FLOOR

P3.8 HOT & COLD WATER PLAN - CR WING B - SECOND

FLOOR

P3.9 HOT & COLD WATER PLAN - CR WING C - SECOND

FLOOR

P4.0 ENLARGED PLUMBING PLANS

PLUMBING DRAWINGS

P4.1 ENLARGED PLUMBING PLANS

P4.2 ENLARGED WASTE & VENT PLAN - KITCHEN

P4.3 ENLARGED HOT & COLD WATER PLAN - KITCHEN

P5.1 PLUMBING DETAILS

P5.2 PLUMBING DETAILS

ARCHITECTURAL DRAWINGS

A10.5 INTERIOR ELEVATIONS

A10.6 INTERIOR ELEVATIONS

A10.7 INTERIOR ELEVATIONS

A10.8 INTERIOR ELEVATIONS

A13.0 DETAILS - FIRE RATED/LIFE SAFETY

A13.1 DETAILS- FIRE RATED/ LIFE SAFETY

A14.0 ROOFING DETAILS

A14.1 ROOFING DETAILS

A14.2 ROOFING DETAILS

A15.0 DETAILS - KITCHEN

A16.0 TYPICAL PLASTIC PARTITION DETAILS

A16.1 TYPICAL SHOWER STALL DETAILS

A17.0 CMU DETAILS

A17.1 DRY WALL DETAILS

A17.2 MISCELLANEOUS DETAILS

A17.3 CAST STONE PROFILES AND DETAILS

A17.4 CAST STONE PROFILES AND DETAILS

1 ADDENDUM #1: 09/26/2023

2 ADDENDUM #2: 10/04/2023

W D

R E

F

I.

C

R E

F

I.

C

D W

WD

REF

I.C.

REF

I.C.

Ƨ

WING A CONT.

WING C

WING B

WING A

GYMNASIUM

MEDIA CENTER

ADMINISTRATION

CAFETERIA

GYMNASIUM

CAFETERIA

MEDIA CENTER

COMPUTER LAB

PACE

PACE

FAMILY LIVING

PSI

KINDERGARTEN

KINDERGARTEN

1ST GRADE

1ST GRADE

INCLUSION/SPED OFFICES

KINDERGARTEN

KINDERGARTEN

KINDERGARTEN

KINDERGARTEN

1308 STOR

1300.2SPEECH

PRE-K

PRE-K

SPEECH

STAIR

1400.1

KINDERGARTEN

KINDERGARTEN

KINDERGARTEN

KINDERGARTEN

STOR

SEC VEST

COMMONS

TEACHER RESOURCE

1ST GRADE

1ST GRADE

1ST GRADE

1ST GRADE

CUST STOR

1700.2

CORRIDOR

1ST GRADE

1ST GRADE

1ST GRADE

1ST GRADE

CUST. STOR

ELEC

IDF

CUST. OFFICE

CORRIDOR

MUSIC

VEST.

P.E. STORAGE

1206.2

CORR.

ACTIVITY LAB/CONF

BROADCAST STUDIO

SECURED VEST

STUDENT RECEPTION

GENERAL OFFICE

VISITOR RECEPTION

CONF.

PRINCIPAL

CORRIDOR

1901.1

OFFICE

OFFICE

OFFICE

COUNSELOR

1915 COUNSELOR

COUNSELOR

SW

AP

TESTING/CONF

CLINIC

EXAM

1908.2

BOOK KEEPER

INFO SPEC

VAULT

1912.2

ELEC

1916 DATA

STAGE

CHAIR STOR

1801.1

DRY FOOD STORAGE

1810 COOLER

FREEZER

SPKLR / RISER

MECH/ELEC

KITCHEN

SERVING

SECURED VEST

RESOURCE RM

STOR

1600.2

STAIR

1600.1

2ND GRADE

2ND GRADE

2ND GRADE

2ND GRADE

2ND GRADE

GIRLS

BOYS

1601T

ELEV.-1

1501.1-1

CONFERENCE

2ND GRADE

2ND GRADE

2ND GRADE

2ND GRADE

INST. WKRM

ELEC

1108IDF

CORRIDOR

1000.2

SRO

1000.1

WORKROOM

SUPPLY

1912.1

TESTING STOR

JAN

DISH RETURN

CORRIDOR

CORRIDOR

CORRIDOR

VAH-9-1

VAH-9-2

VAH-10-1

VAH-10-2

VAH-10-3

HRC-10

VAH-10-5

EH-9

EF-11

VAH-10-4

EH-7

VAH-9-3

VAH-9-4

VAH-9-5

VAH-7-1

VAH-7-2

VAH-7-3

VAH-7-4

EH-5

VAH-7-7

VAH-7-6

VAH-7-5

VAH-6-8

VAH-6-7

VAH-6-6

VAH-6-3

VAH-4-6

VAH-4-5

VAH-6-2

VAH-5-6

VAH-4-4

VAH-4-3

VAH-5-5

HRC-5

VAH-5-4

EH-4

VAH-5-1

VAH-5-2

VAH-5-3

VAH-6-1

DAH-4

VAH-6-4

HRC-6

VAH-6-5

DAH-5

HRC-10

HRC-9

HRC-7

EH-10

VAH-4-2

VAH-4-1

EF-10

EH-8

VAH-8-1

VAH-8-2

VAH-8-3

VAH-8-4

EH-6

STOR

1400.2

VAH-8-5

VAH-8-6

VAH-8-7

VAH-8-8

HRC-8

HRC-4

VHP-4

DOAS-2 RAC-3

DAH-3

RAC-4

VAH-4-8

VAH-3-11

HRC-3

VAH-3-7

VAH-3-9VAH-3-8

VAH-3-6

RAC-2

VAH-3-5

VAH-3-4

VAH-3-3

DAH-2 VAH-3-1

EF-1

VAH-3-10

RAC-1

DOAS-1

VAH-2-5

VAH-2-7

HRC-1

VAH-1-8 VAH-1-7 VAH-1-6

VAH-1-5

VAH-1-4

VAH-1-2

VAH-1-3

VAH-1-1

VAH-2-8

VAH-2-1

HRC-2

VAH-2-4

VAH-2-3

VAH-2-2

DAH-1

VAH-2-6

VAH-1-9

VAH-1-10

DAH-9

EH-2

EF-5

EF-6

RAC-6

DHP-9

EF-2

RAC-5

FF-1

EH-1

EF-3

EF-4

MAU-1

KEF-1

VAH-4-9

HVAC SHEET NOTES

A CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE A COMPLETE AND

WORKING SYSTEM.

B INSTALL, SUPPORT, & BRACE NEW DUCTWORK AND ACCESSORIES PER

SMACNA GUIDELINES.

C DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. CONTRACTOR

SHALL MAKE ALLOWANCE FOR ANY INTERIOR LINING, INSULATION, ETC.

D ALL NEW DUCT ELBOWS SHALL BE RADIUS TYPE. WHERE NECESSARY,

CONTRACTOR MAY SUBSTITUTE MITERED ELBOWS WITH TURNING

VANES.

E PROVIDE FLAT BLADE MANUAL VOLUME DAMPERS AT ALL TERMINAL

DUCT BRANCHES AND AS INDICATED.

F INSTALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS.

ROOFTOP EQUIPMENT SHALL BE LOCATED NO CLOSER THAN 10'-0" FROM

THE ROOF EDGE.

G ALL PRIMARY CONDENSATE DRAIN PIPING SHALL BE INSULATED TO A

MINIMUM THICKNESS OF 1/2" AND SHALL INCLUDE A VAPOR RETARDANT

OUTSIDE THE INSULATION. SEAL ALL JOINTS AND PENETRATIONS.

H COORDINATE ALL EXTERIOR PENETRATIONS INCLUDING ROOF

PENETRATIONS WITH OTHER TRADES TO PROVIDE A COMPLETE AND

FULLY WEATHER-PROOF INSTALLATION.

I ALL TRANSFER DUCTWORK SHALL BE INTERNALLY LINED WITH MINIMUM

1/2" ACOUSTIC LINING.

J CONTRACTOR SHALL ENGAGE A TESTING AND BALANCE FIRM CERTIFIED

BY AABC TO PERFORM TESTING AND BALANCING PROCEDURES ON EACH

SYSTEM ACCORDING TO THE PROCEDURES CONTAINED IN AABC'S

"NATIONAL STANDARDS. FOR TESTING AND BALANCING HEATING,

VENTILATING, AND AIR CONDITIONING SYSTEMS" AND PROVIDE TWO

COPIES OF THE CERTIFIED TAB REPORTS.

MethodEG.com 912-963-1611

W A

R N

IN

G

C on tr ac to rs su bc on tr ac to rs ve nd or s an d su pp lie rs a re a dv is ed t ha t t he c on tr ac t do cu m en ts c on si st o f

A rc hi te ct -r ep ro du ce d pr in te d, b ou nd a nd n um be re d sp ec ifi ca tio ns

A rc hi te ct -r ep ro du ce d pr in te d, b ou nd a nd nu m be re d bl ue or b la ck -li ne p rin ts

, a dd en da

, p os t-bi d ad de nd a, a nd c ha ng e or de rs o nl y.

D oc um en ts r ep ro du ce d rt ie s ot he r th an th e A rc hi te ct

, w he th er in h ar d co py o r in e le ct ro ni c fo rm at

, s ha ll no t b e co ns id er ed p ar t o f th e co nt ra ct d oc um en ts a nd d o no t su pe rs ed e th e pr ov is io ns o f t he c on tr ac t d oc um en ts

T he c on tr ac to r, s ub co nt ra ct or s, ve or s an d su pp lie rs a re s ol el y re sp on si bl e fo r ve rif ic at io n th at in fo rm at io n ut ili ze d in b id di ng de ve lo pm en t of s ho p dr aw in gs an d co ns tr uc tio n of t he fa ci lit y ar e id en tic al to t he c on tr ac t do cu m en ts

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

Copyright (c) 2019 All Rights Reserved.

ISSUED FOR:

NOT VALID UNLESS SIGNED

JA

M

E S

W

B U

C K

L E

Y

A S

S O

C

IA

T E

S I

N C

A R

C H

IT

E

C T

S S

W A

IN

S

B O

R O

A

L B

A N

Y R

O M

E A

N D

S A

V A

N N

A H

G E

O R

G

IA

SHEET

NUMBER:

9/

/2

6:

:5

A

M A ut od es k

D oc s:

//2

B lo om in gd al e

E le m en ta ry

S ch oo l/2

1- B lo om in gd al e

E S

-M E

P -R

V

.r vt

H V

A C

C O

M P

O S

IT

E

P L

A N

F

IR

S

T F

L O

O R

B L

O O

M

IN

G D

A L E

E L

E M

E N

T A

R Y

S C

H O

O L

09/13/2023

22-072

AMM

AMM

BMW

FINAL/BID

S A

V A

N N

A H

-C H

A T

H A

M C

O U

N T

Y P

U B

L

IC

S C

H O

O L

S Y

S T

E M

B L

O O

M

IN

G D

A L

E G

E O

R G

IA

S

C H

O O

L C

O D

E

-4

M1.0SCALE: 1/16" = 1'-0"M1.0

1 LEVEL 1 HVAC PLAN

No. PE044663

PROFESSIONAL

G

E O R G

I

A

RE

G ISTERED

ENG INE ER

B R A N

D O N M. W

EB

S T E R

09/13/2023

E

FI.C

WING A CONT.

WING C

WING B

WING A

VAH-11-2

VAH-11-3

VAH-11-4

VAH-11-6

VAH-11-7

VAH-12-1

VAH-12-2

VAH-11-5

VAH-11-12

VAH-11-1

VAH-14-1

VAH-14-2

VAH-14-3

VAH-14-4

VAH-14-9

VAH-14-6

VAH-14-8

VAH-16-6

DAH-7

DAH-8

VAH-16-3

VAH-16-2

VAH-16-1

VAH-15-2

VAH-15-6

VAH-15-1

VAH-15-3

VAH-15-4

VAH-15-5

VAH-16-4

VAH-16-5

VAH-13-1

VAH-13-2

VAH-13-3

VAH-13-4

VAH-13-8

VAH-13-7

VAH-13-6

VAH-13-5

VAH-12-10

DAH-6

VAH-12-9

VAH-12-7

VAH-12-6

VAH-12-5VAH-12-3

DHP-5

DHP-6

VHP-6

VHP-12

DOAS-4

DOAS-3

HRC-11

VHP-5VHP-11

VHP-14

VHP-8

EF-9

HRC-14

EF-7

VAH-14-5

HRC-12 VAH-12-4

VAH-12-8

DHP-8

DHP-7

HRC-15

VHP-10

VHP-16

3RD GRADE

CORRIDOR

2600 3RD GRADE

3RD GRADE

3RD GRADE

CONFERENCE

STORAGE

2602.1

BOYS

COMMONS

VEST

CONF./OFFICE

AP

COUNSELOR

IDF

ELEC

4TH GRADE

4TH GRADE

4TH GRADE

4TH GRADE

4TH GRADE

STAIR

2700.1

CORRIDOR

4TH GRADE

4TH GRADE

4TH GRADE

4TH GRADE

BOOK STORAGE

VHP-7VHP-13

HRC-13

HRC-16

VHP-9

VHP-15

STAIR

2600.1

3RD GRADE

3RD GRADE

3RD GRADE

3RD GRADE

3RD GRADE

CUST STOR

MDF/IDF

2501.1

CONFERENCE

ELEV EQUIP

ELEV.-2

1501.1-2

GIRLS

STAIR

2500.1

WMN

2402.1

MEN

2402.2

VEST

TEACHER RESOURCE

STEM

ART

ENERGY LAB

SPARE CR

SPARE CR

CORRIDOR

STAIR

2400.1

STOR

2401.1

EF-8

ELEC

JAN

VAH-14-7

GIRLS

BOYS

CORRIDOR

5TH GRADE

5TH GRADE

5TH GRADE

5TH GRADE

STAIR

2300.1

5TH GRADE

5TH GRADE

5TH GRADE

5TH GRADE

5TH GRADE

JAN

CORRIDOR

HVAC SHEET NOTES

A CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE A COMPLETE AND

WORKING SYSTEM.

B INSTALL, SUPPORT, & BRACE NEW DUCTWORK AND ACCESSORIES PER

SMACNA GUIDELINES.

C DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. CONTRACTOR

SHALL MAKE ALLOWANCE FOR ANY INTERIOR LINING, INSULATION, ETC.

D ALL NEW DUCT ELBOWS SHALL BE RADIUS TYPE. WHERE NECESSARY,

CONTRACTOR MAY SUBSTITUTE MITERED ELBOWS WITH TURNING

VANES.

E PROVIDE FLAT BLADE MANUAL VOLUME DAMPERS AT ALL TERMINAL

DUCT BRANCHES AND AS INDICATED.

F INSTALL EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS.

ROOFTOP EQUIPMENT SHALL BE LOCATED NO CLOSER THAN 10'-0" FROM

THE ROOF EDGE.

G ALL PRIMARY CONDENSATE DRAIN PIPING SHALL BE INSULATED TO A

MINIMUM THICKNESS OF 1/2" AND SHALL INCLUDE A VAPOR RETARDANT

OUTSIDE THE INSULATION. SEAL ALL JOINTS AND PENETRATIONS.

H COORDINATE ALL EXTERIOR PENETRATIONS INCLUDING ROOF

PENETRATIONS WITH OTHER TRADES TO PROVIDE A COMPLETE AND

FULLY WEATHER-PROOF INSTALLATION.

I ALL TRANSFER DUCTWORK SHALL BE INTERNALLY LINED WITH MINIMUM

1/2" ACOUSTIC LINING.

J CONTRACTOR SHALL ENGAGE A TESTING AND BALANCE FIRM CERTIFIED

BY AABC TO PERFORM TESTING AND BALANCING PROCEDURES ON EACH

SYSTEM ACCORDING TO THE PROCEDURES CONTAINED IN AABC'S

"NATIONAL STANDARDS. FOR TESTING AND BALANCING HEATING,

VENTILATING, AND AIR CONDITIONING SYSTEMS" AND PROVIDE TWO

COPIES OF THE CERTIFIED TAB REPORTS.

MethodEG.com 912-963-1611

W A

R N

IN

G

C on tr ac to rs su bc on tr ac to rs ve nd or s an d su pp lie rs a re a dv is ed t ha t t he c on tr ac t do cu m en ts c on si st o f

A rc hi te ct -r ep ro du ce d pr in te d, b ou nd a nd n um be re d sp ec ifi ca tio ns

A rc hi te ct -r ep ro du ce d pr in te d, b ou nd be re d bl ue or b la ck -li ne p rin ts

, a dd en da

, p os t-bi d ad de nd a, a nd c ha ng e or de rs o nl y.

D oc um en ts r ep ro du ce ie s ot he r th an th e A rc hi te ct

, w he th er in h ar d co py o r in e le ct ro ni c fo rm at

, s ha ll no t b e co ns id er ed p ar t o f th e co nt ra ct d oc um en ts a nd d o no t su pe rs ed e th e pr ov is io ns o f t he c on tr ac t d oc um en ts

T he c on tr ac to r, s ub co nt ra ct or s an d su pp lie rs a re s ol el y re sp on si bl e fo r ve rif ic at io n th at in fo rm at io n ut ili ze d in b id di ng de ve lo pm en t of s ho p dr aw in gs an d co ns tr uc tio n of t he fa ci lit y ar e id en tic al to t he c on tr ac t do cu m en ts

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

Copyright (c) 2019 All Rights Reserved.

ISSUED FOR:

NOT VALID UNLESS SIGNED

JA

M

E S

W

B U

C K

L E

Y

A S

S O

C

IA

T E

S I

N C

A R

C H

IT

E

C T

S S

W A

IN

S

B O

R O

A

L B

A N

Y R

O M

E A

N D

S A

V A

N N

A H

G E

O R

G

IA

SHEET

NUMBER:

9/

/2

6:

:1

A

M A ut od es k

D oc s:

//2

B lo om in gd al e

E le m en ta ry

S ch oo l/2

1- B lo om in gd al e

E S

-M E

P -R

V

.r vt

H V

A C

C O

M P

O S

IT

E

P L

A N

S

E C

O N

D F

L O

O R

B L

O O

M

IN

G D

A L E

E L

E M

E N

T A

R Y

S C

H O

O L

09/13/2023

22-072

AMM

AMM

BMW

FINAL/BID

S A

V A

N N

A H

-C H

A T

H A

M C

O U

N T

Y P

U B

L

IC

S C

H O

O L

S Y

S T

E M

B L

O O

M

IN

G D

A L

E G

E O

R G

IA

S

C H

O O

L C

O D

E

-4

M1.1

SCALE: 1/16" = 1'-0"M1.1

1 LEVEL 2 HVAC PLAN

No. PE044663

PROFESSIONAL

G

E O R G

I

A

RE

G ISTERED

ENG INE ER

B R A N

D O N M. W

EB

S T E

09/13/2023

LEGEND

LIGHTING AND POWER

A-2,4,6

CONDUIT RUN CONCEALED ABOVE CEILING OR IN WALL CONTAINING 3 NUMBER 12

CONDUCTORS UNLESS SHOWN OTHERWISE. HASH MARKS, IF SHOWN, INDICATE QUANTITY

OF NUMBER 12 CONDUCTORS. WHERE DRAWING SPACE PROHIBITS HASH MARKS BEING

SHOWN REFER TO CIRCUIT NUMBERS AND PROVIDE REQUIRED NUMBER OF CONDUCTORS

PER CIRCUIT TYPE.

CONDUIT RUN CONCEALED IN OR BELOW FLOOR SLAB, OR UNDERGROUND.

HOMERUN TO PANELBOARD, LETTER OR LETTERS INDICATE PANELBOARDS, NUMBERS

INDICATE CIRCUIT NUMBERS.

EXPOSED CONDUIT RUN.

2-E L.E.D. LIGHTING FIXTURE, "2" INDICATES THE CIRCUIT NUMBER AND "E" THE FIXTURE TYPE.

SEE FIXTURE SCHEDULE FOR DIMENSIONS AND MOUNTING TYPE.

EMERGENCY L.E.D. LIGHTING FIXTURE. SEE FIXTURE SCHEDULE FOR DIMENSIONS,

MOUNTING TYPE AND BATTERY PACK INFORMATION (IF APPLICABLE).

L.E.D. FIXTURE, SURFACE OR STEM MOUNTED.

L.E.D. TROFFER FIXTURE. SEE FIXTURE SCHEDULE FOR DIMENSIONS

AND MOUNTING TYPE.

EMERGENCY L.E.D. TROFFER. SEE FIXTURE SCHEDULE FOR DIMENSIONS, MOUNTING TYPE

AND BATTERY PACK INFORMATION (IF APPLICABLE).

L.E.D. LIGHTING FIXTURE, SURFACE WALL BRACKET MOUNTED. MOUNTING HEIGHT AS

NOTED.

L.E.D. LIGHTING FIXTURE, SURFACE WALL BRACKET MOUNTED. MOUNTING HEIGHT AS

NOTED. SEE FIXTURE SCHEDULE FOR BATTERY PACK INFORMATION (IF APPLICABLE).

L.E.D. CHANDELIER OR PENDANT FIXTURE. CEILING PENDANT MOUNTED.

EXIT LIGHT.

JUNCTION BOX, FLUSH WALL MOUNTED.

JUNCTION BOX LOCATED ABOVE CEILING OR BELOW GRADE.

JUNCTION BOX, FLUSH WALL MOUNTED.

TAMPER RESISTANT (TR) DUPLEX CONVENIENCE OUTLET, +18" TO CENTER LINE OF

OUTLET UNLESS OTHERWISE NOTED. 5" INDICATES THE CIRCUIT NUMBER.

TAMPER RESISTANT (TR) DUPLEX CONVENIENCE OUTLET MOUNTED ABOVE COUNTER, AT

+46" TO CENTERLINE OF OUTLET.

TAMPER RESISTANT (TR) DUPLEX CONVENIENCE OUTLET, GFI TYPE. +18" TO CENTER LINE

UNLESS OTHERWISE NOTED. "WP" WHERE SHOWN INDICATES WEATHER-RESISTANT

DEVICE WITH METAL IN-USE WEATHERPROOF COVER.

TAMPER RESISTANT (TR) DUPLEX CONVENIENCE OUTLET, GFI TYPE. MOUNTED ABOVE

COUNTER AT +46" TO CENTERLINE OF RECEPTACLE UNLESS NOTED OTHERWISE.

SPECIAL RECEPTACLE TO SUIT EQUIPMENT FURNISHED.

TAMPER RESISTANT (TR) QUADRUPLEX RECEPTACLE, +18" TO CENTER LINE OF OUTLET

UNLESS OTHERWISE NOTED.

TAMPER RESISTANT (TR) QUADRUPLEX RECEPTACLE, +46" TO CENTER LINE OF OUTLET

UNLESS OTHERWISE NOTED.

FLUSH FLOOR RECEPTACLE, IN FLOOR BOX WITH HINGED COVER.

TAMPER RESISTANT (TR) DUPLEX CONVENIENCE OUTLET CONNECTED TO EMERGENCY

POWER, +18" TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED.

TAMPER RESISTANT (TR) DUPLEX CONVENIENCE OUTLET CONNECTED TO EMERGENCY

POWER, +46" TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED.

TAMPER RESISTANT (TR) QUADRUPLEX CONVENIENCE OUTLET CONNECTED TO

EMERGENCY POWER, +18" TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED.

TAMPER RESISTANT (TR) QUADRUPLEX CONVENIENCE OUTLET CONNECTED TO

EMERGENCY POWER, +46" TO CENTER LINE OF OUTLET UNLESS OTHERWISE NOTED.

TAMPER RESISTANT (TR) GFCI DUPLEX CONVENIENCE OUTLET CONNECTED TO

EMERGENCY POWER, +18" TO CENTERLINE OF RECEPTACLE UNLESS NOTED OTHERWISE.

TAMPER RESISTANT (TR) GFCI DUPLEX CONVENIENCE OUTLET CONNECTED TO

EMERGENCY POWER, +46" TO CENTERLINE OF RECEPTACLE UNLESS NOTED OTHERWISE.

TAMPER RESISTANT (TR) FLUSH FLOOR BOX WITH QUADRUPLEX RECEPTACLE AND

DATA/VOICE OUTLET. SEE SPECIFICATIONS FOR TYPE OF BOX.

SINGLE POLE TOGGLE SWITCH, +46" TO CENTER LINE MOUNTING HEIGHT.

THREE OR FOUR WAY SWITCH AS INDICATED. +46" TO CENTER LINE MOUNTING HEIGHT.

KEY OPERATED SINGLE POLE TOGGLE SWITCH, +46" TO CENTER LINE MOUNTING HEIGHT.

LED DECORA STYLE DIMMER WITH ROCKER ON/OFF SWITCH AND SLIDE DIMMER ON SIDE

OF ROCKER. 0-10VDC CAPABLE DIMMER +3'-6" MOUNTING HEIGHT. LUTRON "DIVA 0-10V" OR

EQUAL BY LEVITON, WATTSTOPPER, HUBBELL, OR COOPER. (NO ADDITIONAL POWER PACK

REQUIRED). DIVISION 26 SHALL PROVIDE ALL ADDITIONAL CONDUCTORS TO ALL FIXTURES

CONNECTED FOR A PROPER 0-10VDC OPERATION. GRAY FINISH.

LED DECORA STYLE DIMMER WITH ROCKER ON/OFF SWITCH AND SLIDE DIMMER ON SIDE

OF ROCKER. 0-10VDC CAPABLE DIMMER WITH PASSIVE INFRARED OCCUPANCY SENSOR. +

3’-6” MOUNTING HEIGHT, GRAY FINISH. LUTRON "DIVA 0-10V" OR EQUAL BY LEVITRON,

WATTSTOPPER, HUBBELL OR COOPER. DIMMER MUST BE COMPATIBLE WITH ALL LIGHTING

COMPONENTS (NO ADDITIONAL POWER PACK REQUIRED). DIVISION 26 SHALL PROVIDE ALL

ADDITIONAL CONDUCTORS TO ALL FIXTURES CONNECTED FOR PROPER 0-10V OPERATION.

LED DECORA STYLE DIMMER WITH ROCKER ON/OFF SWITCH AND SLIDE DIMMER ON SIDE

OF ROCKER. 0-10VDC CAPABLE THREE WAY DIMMER, +3'-6" MOUNTING HEIGHT. LUTRON

"DIVA 0-10V" OR EQUAL BY LEVITON, WATTSTOPPER, HUBBELL, OR COOPER. (NO

ADDITIONAL POWER PACK REQUIRED). DIVISION 26 SHALL PROVIDE ALL ADDITIONAL

CONDUCTORS TO ALL FIXTURES CONNECTED FOR A PROPER 0-10VDC OPERATION. GRAY

FINISH.

LOW VOLTAGE SWITCH WALL MOUNTED. +46" TO CENTER LINE MOUNTING HEIGHT.. SEE

LOW VOLTAGE SWITCHING NOTES FOR SWITCH BUTTON QUANTITY, CONFIGURATION, AND

OPERATION.

PANELBOARD, SEE SCHEDULE.

FIRE ALARM SYSTEM

VOICE EVACUATION SIGNAL, SPEAKER, AND STROBE LIGHT, +6'-10" MOUNTING HEIGHT TO

CENTER OF DEVICE, UNLESS NOTED BY "C" MOUNT TO CEILING.

HEAT DETECTOR, CEILING MOUNTED.

SMOKE DETECTOR, CEILING MOUNTED.

CARBON MONOXIDE DETECTOR, CEILING MOUNTED.

TAMPER SWITCH, FURNISHED AND INSTALLED WITH SPRINKLER SYSTEM. INTERLOCK WITH

FIRE ALARM SYSTEM BY ELECTRICAL.

FLOW SWITCH, FURNISHED AND INSTALLED WITH SPRINKLER SYSTEM. INTERLOCK WITH

FIRE ALARM SYSTEM BY ELECTRICAL.

SIGNAL, CHIME, AND STROBE LIGHT, 6'-10" MOUNTING HEIGHT.

STROBE LIGHT, 6'-10" MOUNTING HEIGHT TO CENTER OF DEVICE.

STROBE LIGHT, CEILING MOUNTED.

PULL STATION. WALL MOUNTED +46" TO CENTER LINE MOUNTING HEIGHT.

FIRE ALARM DOCUMENTATION BOX.

FIRE ALARM CONTROL PANEL. SURFACE WALL MOUNTED.

FIRE ALARM LCD REMOTE ALPHANUMERIC ANNUNCIATOR. FLUSH WALL MOUNTED.

DUCT SMOKE DETECTOR, LOCATED AT HVAC UNIT OR UP STREAM OF SMOKE DAMPER.

COORDINATE EXACT LOCATION WITH MECHANICAL DRAWINGS PRIOR TO ROUGHING IN.

J

J

VE

SL

SL

FACP

DOC

FAA

DD

VS

WF

C H

FIRE ALARM CONNECTION TO HOOD EXTINGUISHING SYSTEM. SEE MECHANICAL

DRAWINGS FOR LOCATION.

FIRE ALARM CONNECTION TO DOOR HOLDER, FLOOR OR WALL MOUNTED. CONSULT

ARCHITECTURAL DRAWINGS TO DETERMINE TYPE REQUIRED.

FIRE ALARM REMOTE ELEVATOR INTERFACE MODULE.

VOICE EVACUATION REMOTE MICROPHONE.

CONTROL/MONITOR MODULE.

TELEPHONE / DATA SYSTEMS

PLYWOOD BACKBOARD "T.B." INDICATES TELECOMMUNICATIONS BOARD.

DATA RACK, 2 POST, WITH VERTICAL CABLE WIRE MANAGEMENT. SEE SPECIFICATIONS.

DATA RACK, 4 POST, WITH VERTICAL CABLE WIRE MANAGEMENT. SEE SPECIFICATIONS.

VOICE OUTLET., +46" TO CENTER LINE OF OUTLET UNLESS NOTED OTHERWISE. STUB UP

1"C. TO CEILING SPACE ABOVE.

DATA OUTLET., +18" TO CENTER LINE OF OUTLET UNLESS NOTED OTHERWISE. STUB UP

1"C. TO CEILING SPACE ABOVE.

DATA OUTLET., +46" TO CENTER LINE OF OUTLET UNLESS NOTED OTHERWISE. STUB UP

1"C. TO CEILING SPACE ABOVE.

DATA OUTLET. (WIRELESS ACCESS POINT), +6" ABOVE ACCESSIBLE CEILING UNLESS NOTED

OTHERWISE. WHERE THERE IS NO CEILING OR HIGH CEILING, WALL MOUNT AT +11' A.F.F.

FCSU

DH

MIC

C M

ESR

TB

W

F

ULTRASONIC OCCUPANCY SENSOR. CEILING MOUNTED (WATTSTOPPER "UT" SERIES OR

EQUAL). PROVIDE ALL NECESSARY COMPONENTS TO INSURE PROPER OPERATION

(POWER PACKS, SLAVE PACKS, ETC.)

ULTRASONIC HALLWAY OCCUPANCY SENSOR. CEILING MOUNTED. (WATTSTOPPER

"WT-2255" OR EQUAL). PROVIDE ALL NECESSARY COMPONENTS TO INSURE PROPER

OPERATION (POWER PACKS, SLAVE PACKS, ETC.)

UO

HO

DISCONNECT SWITCH, SIZE AS NOTED ON DRAWINGS. FUSED PER MANUFACTURER'S

NAME PLATE DATA OF EQUIPMENT SERVED.

MANUAL MOTOR STARTER / DISCONNECT. SIZE AS NOTED ON DRAWINGS.

SINGLE OR DOUBLE POLE, MINIMUM 20 AMP MOTOR RATED ENCLOSED SWITCH WITH

"LOCK-OUT" OPTION. MOUNTED NEAR EQUIPMENT BEING SERVED.

MOTOR.M

PROVIDE 4 11/16" SQUARE BY 3-1/2" DEEP JUNCTION BOX WITH 1 1/2" CONDUIT

STUBBED UP TO ABOVE CEILING. AUDIO/VISUAL OUTLET. SEE DETAIL 3/8.4.

AV

2" EMT TROUGH WALL WITH PLASTIC BUSHINGS ON EACH END. UNLESS OTHERWISE

NOTED.

EMERGENCY OVERRIDE LIGHTING RELAY "BYPASS". SEE DETAIL 8/E8.2.

EMERGENCY OVERRIDE LIGHTING RELAY "NORMAL". SEE DETAIL 1/E8.3.

WALL MOUNTED 120V HAND DRYER. COORDINATE EXACT HEIGHT WITH ARCHITECTURAL

ELEVATIONS PRIOR TO ROUGH-IN.

ELECTRICAL WATER COOLER. PROVIDE A DUPLEX RECEPTACLE AT WATER COOLER.

CIRCUIT SHALL BE GFCI PROTECTED. REFER TO DETAIL 3/E8.1 FOR ROUGH-IN.

POWER SUPPLY. PROVIDE JUNCTION BOX AND 120V CONNECTION.

E O

E N

HD

WC

PS

CABLE TRAY SIZE: 18"W x 4"H TYP.

GENERATOR REMOTE ANNUNCIATOR. FLUSH RECESSED MOUNTED.G

A

OCCUPANCY SENSORS

SWITCH, WALL MOUNTED OCCUPANCY SENSOR (WATTSTOPPER PW-100 OR EQUAL). +46"

TO CENTER LINE MOUNTING HEIGHT.

DUAL TECHNOLOGY 360° OCCUPANCY SENSOR. CEILING MOUNTED. INFRARED/ULTRASONIC

(WATTSTOPPER "DT" SERIES OR EQUAL). PROVIDE ALL NECESSARY COMPONENTS TO

INSURE PROPER OPERATION (POWER PACKS, SLAVE PACKS, ETC.)

os

ACCESS CONTROLS SYSTEM (BACKBOXES AND CONDUIT ONLY, SYSTEMS BY OTHERS)

DOOR CONTACT POSITION SENSOR LOCATION. PROVIDE SINGLE GANG BOX BY DIVISION

16 AT DOOR FRAME ON SECURE SIDE OF DOOR. COORDINATE EXACT LOCATION WITH

ACCESS CONTROL SYSTEM VENDOR. PROVIDE 3/4"C., WITH PULLSTRING FROM BOX TO

STUB-OUT 6" ACCESSIBLE CEILING AT DOOR. SEE DETAIL 3/E8.2.

ACCESS CONTROL HEAD END.

C.C.T.V. SYSTEM

CCTV SYSTEM CAMERA, WALL OR CEILING MOUNTED. NUMBER DESIGNATES CAMERA

NUMBER, "WP" INDICATES WEATHERPROOF.

CCTV SYSTEM HEAD END EQUIPMENT.

CCTV SYSTEM MONITOR. VERIFY LOCATIONS WITH ARCHITECT/OWNER.

TELEVISION OUTLET, +98" TO CENTER LINE, UNLESS OTHERWISE NOTED. LOCATE DUPLEX

OUTLET SHOWN DIRECTLY ADJACENT TO T.V. OUTLET AT SAME HEIGHT.

INTRUSION ALARM SYSTEM

INTRUSION ALARM DETECTOR, INFRARED. CEILING MOUNTED UNIT. 50'-0" COVERAGE

UNLESS OTHERWISE NOTED.

INTRUSION ALARM, KEY PAD. +46" TO CENTER LINE MOUNTING HEIGHT.

INTRUSION ALARM CONTROL PANEL.

SOUND SYSTEM

SPEAKER, CEILING RECESSED.

SPEAKER FLUSH WALL MOUNTED. SEE DRAWING FOR MOUNTING HEIGHT. "WP" WHERE

SHOWN INDICATES EXTERIOR WEATHERPROOF SPEAKER.

EMERGENCY CALL STAFF STATION. +46" TO CENTER LINE MOUNTING HEIGHT. HANDSET

TYPE. SEE SPECIFICATIONS.

CALL-IN STATION WITH MONITOR SPEAKER ATLAS-SOUNDOLIER #VPVT +48" MOUNTING

HEIGHT TO COMPLY WITH ADA. FLUSH WALL MOUNTED. "WP" WHERE SHOWN INDICATES

EXTERIOR WEATHERPROOF OUTLET BOX AND COVER.

VOLUME CONTROL, +46" TO CENTER LINE MOUNTING HEIGHT.

SOUND CABINET. SEE SPECIFICATIONS.

ADMINISTRATION INTERCOM TELEPHONE OUTLET AND PHONE (BOGEN MODEL MCDS4).

MOUNT +18" ABOVE FINISHED FLOOR TO CENTER OF OUTLET.

STAFF INTERCOM TELEPHONE OUTLET AND PHONE (BOGEN MODEL MCDS4). MOUNT +18"

ABOVE FINISHED FLOOR TO CENTER OF OUTLET.

I

I K

C P

S

S WP

E

ES

V

SC

A

S

TV

C

CC

M

AC

DC

A C

PRIORITY EMERGENCY CALL PUSHBUTTON. INTERFACE TO PHONE LINE FOR DIRECT 911

CALL. ADEMCO #268.

"AREA OF REFUGE" INDICATOR SIGN, DIE CAST ALUMINUM HOUSING, GREEN LETTERING

WITH "AREA OF REFUGE" LETTERING AND PICTOGRAM. FIXTURE SHALL BE OF SAME

MANUFACTURER AS TYPE "X" EXIT SIGN. TIE INTO EXIT SIGN CIRCUIT.

AREA OF REFUGE MASTER STATION. +48" AFF RECEIVES ALL CALLS FROM "AREA OF

REFUGE PHONES" SHOWN.

"AREA OF REFUGE PHONE" FLUSH MOUNTED AT 42" AFF. DEDICATED TWO-WAY

COMMUNICATION DEVICE TO BE CONNECTED TO CENTRAL PHONE LOCATION IN GENERAL

OFFICE 1901 AS WELL AS PROGRAMMED TO DIAL OFF SITE LOCATION. DEVICE SHALL HAVE

STAINLESS STEEL COVER WITH SINGLE PUSHBUTTON OPERATION AND LABELED AS

"EMERGENCY PHONE" (BRAILLE LABELING INCLUDED), PROVIDE SIGNAGE (TALK-A-PHONE #

ETP-SIGN-PFH) AND EMERGENCY PHONE (TALK-A-PHONE #ETP-400V)

AREA OF REFUGE COMMUNICATION SYSTEM SEE SHEETS E5.3 AND E5.4

AR

AR M

L

AR

E

ACCESS CONTROL CARD ACCESS VIDEO DOOR STATION WITH SURFACE MOUNTED

BACKBOX. SURFACE MOUNT AT +54" A.F.F. SEE DETAIL 3/E8.2.

ACCESS CONTROL CREDENTIAL READER. PROVIDE UNIT WITH CARD SWIPE/ PROXIMITY

READER AND CONNECT TO ACCESS CONTROL SYSTEM. MOUNT AT +48" A.F.F. SEE DETAIL

3/E8.2.

CR

TRACK LIGHT FIXTURE(S). CEILING OR PENDANT MOUNTED.

AMPLIFIER, FLUSH WALL MOUNTED ENCLOSURE.

MICROPHONE OUTLET, FLUSH WALL MOUNTED +3'-6" ABOVE FINISHED FLOOR UNLESS

OTHERWISE NOTED.

A

TAMPER RESISTANT (TR) FLUSH POKE THRU WITH QUADRUPLEX RECEPTACLE AND

DATA/VOICE OUTLET. SEE SPECIFICATIONS FOR TYPE OF POKE THRU.

(BACKBOXES AND CONDUIT ONLY. SYSTEMS BY OTHERS.)

(BACKBOXES AND CONDUIT ONLY, SYSTEMS BY OTHERS.)

(BACKBOXES AND CONDUIT ONLY, SYSTEMS BY OTHERS.)

DUAL TECHNOLOGY 360° OCCUPANCY SENSOR. CEILING MOUNTED. HIGHBAY TYPE.os

HB

PANEL

DESIGNATION:

FIXTURE TYPE:

TYPE "A" IF NO

CAPITAL LETTER

SHOWN

B/ HA1 -1, b

SWITCH LEG

DESIGNATION

WHEN MULTIPLE

SWITCHES ARE IN

SAME SPARE/AREA

CIRCUIT

NUMBER:

EXAMPLE: B/HA1-1,b

LIGHT FIXTURE

DESIGNATION DESCRIPTION

EQUIPMENT ID:

MECHANICAL/

PLUMBING

EQUIPMENT

PANEL - CIRCUIT

NUMBER:

EXAMPLE:

MECHANICAL EQUIPMENT

TAG DESCRIPTION

NOTE: REFER TO MECHANICAL CONNECTION SCHEDULES FOR

CIRCUITING INFORMATION

RAC-1

HR-7,9,11

RAC-1

HR-7,9,11

A M

E S

E.

J

FLE M I

NO. PE326

PROFESSIONAL

I I I

G

EORGIA

REG

ISTERED

ENGINEER

N

G

ELECTRICAL ENGINEERS

1201 BROAD ST., SUITE 1-A

AUGUSTA, GA 30901

PH: (706) 724-3551

FAX: (706) 724-8507

EDC PROJECT #:

W A

R N

IN

G

C on tr ac to rs su bc on tr ac to rs ve nd or s an d su pp lie rs a re a dv is ed t ha t t he c on tr ac t do cu m en ts c on si st o f

A rc hi te ct -r ep ro du ce d pr in te d, b ou nd a nd n um be re d sp ec ifi ca tio ns

A rc hi te ct -r ep ro du ce d pr in te d, b ou nd be re d bl ue or b la ck -li ne p rin ts

, a dd en da

, p os t-bi d ad de nd a, a nd c ha ng e or de rs o nl y.

D oc um en ts r ep ro du ce ie s ot he r th an th e A rc hi te ct

, w he th er in h ar d co py o r in e le ct ro ni c fo rm at

, s ha ll no t b e co ns id er ed p ar t o f th e co nt ra ct d oc um en ts a nd d o no t su pe rs ed e th e pr ov is io ns o f t he c on tr ac t d oc um en ts

T he c on tr ac to r, s ub co nt ra ct or s an d su pp lie rs a re s ol el y re sp on si bl e fo r ve rif ic at io n th at in fo rm at io n ut ili ze d in b id di ng de ve lo pm en t of s ho p dr aw in gs an d co ns tr uc tio n of t he fa ci lit y ar e id en tic al to t he c on tr ac t do cu m en ts

PROJECT NUMBER

PROJECT DATE

APPROVED BY

CHECKED BY

DRAWN BY

Copyright (c) 2023 All Rights Reserved.

ISSUED FOR:

JA

M

E S

W

B U

C K

L E

Y

A S

S O

C

IA

T E

S I

N C

A R

C H

IT

E

C T

S S

W A

IN

S

B O

R O

A

L B

A N

Y R

O M

E A

N D

S A

V A

N N

A H

G E

O R

G

IA

SHEET

NUMBER:

23060

9 13 23

9/

/2

:1 4:

P

M A ut od es k

D oc s:

//2

B lo om in gd al e E

S /2

E D

C E le ct ric al

R

B lo om in gd al e E

S .r vt

L E

G E

N D

N

O T

E S

D

E T

A

IL

S A

N D

F

IX

T U

R E

S C

H E

D U

L E

B L

O O

M

IN

G D

A L E

E L

E M

E N

T A

R Y

S C

H O

O L

09/13/2023

22-072

JEF

JEF

AN/CT

FINAL/BID

S A

V A

N N

A H

-C H

A T

H A

M C

O U

N T

Y P

U B

L

IC

S C

H O

O L

S Y

S T

E M

B L

O O

M

IN

G D

A L

E G

E O

R G

IA

S

C H

O O

L C

O D

E

-4

E1.0

LIGHTING FIXTURE SCHEDULE

TYPE DESCRIPTION WATTS LUMENS

COLOR

TEMP MANUFACTURERS NOTES

A1 LED FIXTURE, 2' x 4' RECESSED CEILING GRID TYPE EDGE-LIT FLAT

PANEL FIXTURE WITH SINGLE PIECE INJECTION FRAME AND SMOOTH

WHITE LENS.

37 W 4000 3500 K METALUX "24FP" SERIES

LITHONIA, COLUMBIA,

ORACLE, JADEMAR

B1 LED FIXTURE, 2' x 4' RECESSED CEILING GRID TYPE BACK-LIT FLAT

PANEL FIXTURE WITH SINGLE PIECE INJECTION FRAME AND SMOOTH

WHITE LENS.

32 W 4000 3500 K LITHONIA "CPX" SERIES

METALUX, COLUMBIA,

ORACLE, JADEMAR

B2 LED FIXTURE, 2' x 4' RECESSED CEILING GRID TYPE BACK-LIT FLAT

PANEL FIXTURE WITH SINGLE PIECE INJECTION FRAME AND SMOOTH

WHITE LENS.

45 W 5000 3500 K LITHONIA "CPX" SERIES

METALUX, COLUMBIA,

ORACLE, JADEMAR

C LED FIXTURE, 2' x 2' RECESSED CEILING GRID TYPE BACK-LIT FLAT

PANEL FIXTURE WITH SINGLE PIECE INJECTION FRAME AND SMOOTH

WHITE LENS.

30 W 3400 3500 K LITHONIA "CPX" SERIES

METALUX, COLUMBIA,

ORACLE, JADEMAR

E1 4' STRIP LIGHT FIXTURE SURFACE MOUNTED WITH WHITE ACRYLIC

LENS AND WHITE FINISH. (SURFACE, STEM, OR CHAIN SUSPEND

WHERE REQUIRED)

43 W 5437 3500 K LITHONIA "CSS" SERIES

METALUX, COLUMBIA, H.E.

WILLIAMS, ILP

F1 RECESSED COMMERCIAL GRADE DOWNLIGHT WITH 6" APERTURE

WITH WHITE TRIM . FIXTURE SHALL BE CONSTRUCTED OUT OF 16

GAUGE GALVANIZED STEEL WITH OPEN DOWNLIGHT REFLECTOR AND

PASSIVE COOLING. WET LISTED.

31 W 2500 3500 K LITHONIA "LBR6" SERIES

PEACHTREE, PRESCOLITE,

HALO COMMERCIAL, ELITE

LIGHTING, LSI, SPECTRUM,

GREEN CREATIVE

F2 RECESSED COMMERCIAL GRADE DOWNLIGHT WITH 6" APERTURE

WITH WHITE TRIM . FIXTURE SHALL BE CONSTRUCTED OUT OF 16

GAUGE GALVANIZED STEEL WITH OPEN DOWNLIGHT REFLECTOR AND

PASSIVE COOLING. WET LISTED.

20 W 1500 3500 K LITHONIA "LBR6" SERIES

PEACHTREE, PRESCOLITE,

HALO COMMERCIAL, ELITE

LIGHTING, LSI, SPECTRUM,

GREEN CREATIVE

HB FULL BODY LED HIGH BAY FIXTURE WITH DIE FORMED ALUMINUM OR

STEEL HOUSING, ANODIZED ALUMINUM REFLECTOR, CLEAR ACRYLIC

LENS WITH WIREGUARD IN DOOR FRAME.WHITE POWDER COAT

FINISH. MOUNT TO BOTTOM OF TRUSS. PROVIDE SAFETY CHAINS ON

WIRE GUARD, TO FIXTURE, TO STRUCTURE ABOVE.

150 W 24000 3500 K LITHONIA IBG SERIES IBG 24L

MVOLT 5K

COOPER

COLUMBIA

LITHONIA

LSI

ILP

LS LED FLOODLIGHT, BLACK FINISH TENON MOUNTED ON TOP OF 12'

ABOVE GRADE RACK POST.

6800 4000 K LITHONIA, STONCO, LUMARK

OE L.E.D. GROUND MOUNTED FLOOD LIGHT WITH ONE PIECE.

LOWCOPPER ALUMINUM ALLOY CONSTRUCTION AND

IMPACTRESISTANT TEMPERED GLASS. FINISH AS SELECTED

BYARCHITECT. COORDINATE BEAM ANGLE TO PROPERLY ILLUMINATE

FLAG POLE.

10000 4000 K KIM LIGHTING "KFL3" SERIES

HYDREL,

COOPER

Q LED FLOOD FIXTURE, DIE-CAST ALUMINUM HOUSING WITH TEMPERED

GLASS LENS WITH ADJUSTABLE BASE MOUNT, 10° DISTRIBUTION, RGB

COLOR CHANGING LED (MAXIMUM LIGHT OUTPUT WHEN WHITE).

FIXTURE SHALL HAVE GLARE VISOR AND HAVE BLACK TEXTURED

FINISH. MOUNTED TO STRUCTURE WITH ALL REQUIRED MOUNTING

EQUIPMENT NECESSARY FOR PROPER INSTALLATION.

DRIVER: 120V WITH DMX CONTROLS. PROVIDE WITH WINONA "EASYL"

DMX CONTROLLER AND BELDEN 9829 CABLE FOR DMX SIGNAL DAISY

CHAINED BETWEEN FIXTURES TO THE CONTROLLER.

1894 4000 K WINONA "PFL707" SERIES

ACCLAIM LIGHTING

INSIGHT LIGHTING

BEACON LIGHTING

GVA LIGHTING

S 4' FIXTURE SURFACE MOUNT, LOW PROFILE, VANDAL RESISTANT.

FIXTURE SHALL BE EQUIPPED WITH MOTION SENSOR.

52 W 5900 3500 K LUMINAIRE "TSL" SERIES,

LITHONIA, METALUX,

COLUMBIA, LAMAR

T1 LED TRACK MOUNTED FIXTURE WITH ALUMINUM HOUSING,

ADJUSTABLE BASE MOUNT, 60 DEGREE DISTRIBUTION, TGB COLOR

CHANGING LED AND WHITE LIGHT OPTION. FIXTURE SHALL HAVE

FINISH. FIXTURE SHALL BE SURFACE MOUNTED IN LENGTH AS

SHOWN, BLAKC FINISH, AND HAVE DMX INOUT CAPABILITIES. PROVIDE

ACCESSORIES AS NEEDED FOR A PROPER MOUNTING AND

INSTALLATION.

2000 4000 K TIMES SQUARE "MOSAIC"

SERIES

ALTMAN, AMERLUX, LITELAB

HELIOS "6R"

T2 LED TRACK MOUNTED FIXTURE WITH FLOOD OPTICS. TGB COLOR

CHANGING LED AND WHITE LIGHT OPTION. FIXTURE SHALL BE

SURFACE MOUNTED IN LENGTH AS SHOWN, WHITE FINISH, AND HAVE

DMX INPUT CAPABILITIES. PROVIDE ACCESSORIES AS NEEDED FOR A

PROPER MOUNTING AND INSTALLATION.

1168 3500 K JUNO "R620L" SERIES OR

EQUAL

W L.E.D WALL MOUNTED FIXTURE, TRAPEZOID HOUSING. TYPE II

DISTRIBUTION WITH FINISH TO BE SELECTED BY ARCHITECT.

COORDINATE MOUNTING HEIGHT WITH ARCHITECT.

18 W 2000 4000 K LITHONIA "WDGE2 LED"

SERIES

GARDCO, HUBBELL, LUMARK,

ILP

A. CONTRACTOR SHALL REFER TO SPECIFICATIONS REGARDING PROVIDING ADDITIONAL SPARE LAMPS, LENSES, AND GLOBES.

B. WHERE "APPROVED EQUAL" IS LISTED IN THE MANUFACTURER COLUMN, FIXTURES MUST BE SUBMITTED AS A SUBSTITUTION FOR APPROVAL PRIOR TO BID SUBMISSION.

C. ALL FIXTURE VOLTAGES SHALL BE MULTI VOLT TYPE UNLESS OTHERWISE NOTED.

D. PROVIDE DIMMING DRIVER, 0-10VDC,1-100% ON ALL FIXTURES EXCEPT TYPES E1, OE, W, AND X.

GENERAL NOTES:

L.E.D. EXIT LIGHT, PROVIDE WITH DIE-CAST BRUSHED ALUMINUM

HOUSING AND GREEN FACED BACKGROUND. UNIVERSAL

MOUNTING.

LAMPS: L.E.D.

DRIVER: MULTI VOLT INPUT

LITHONIA "LQC" SERIES

SURE-LITE "CX" SERIES

CHLORIDE "46 LINE" SERIES

DUAL-LITE "SEMPRA" SERIES

1. DO NOT SCALE DRAWINGS TO LOCATE EQUIPMENT OR OUTLETS.

2. MOUNTING HEIGHTS AS INDICATED ON THE DRAWINGS SHALL BE FROM THE FINISHED FLOOR TO THE

CENTER LINE OF THE OUTLET BOX.

3. THE ELECTRICAL DRAWINGS ARE ONLY A PART OF THE CONTRACT DOCUMENTS. ALL OF THE DRAWINGS AND SPECIFICATIONS MUST BE REVIEWED FOR THEIR INTERRELATIONSHIP AND REQUIRED COORDINATION

BETWEEN DISCIPLINES.

4. SYMBOL INDICATING ROOM OR SPACE NUMBER.

5. IN AREAS WHERE COMPUTER OUTLETS AND TELEPHONE OUTLETS ARE LOCATED BENEATH A WINDOW, AND WINDOW PREVENTS THE ROUTING OF CONDUIT UP TO CEILING SPACE, CONDUIT SHALL BE ROUTED TO A

WALL WHICH ALLOWS CONDUIT TO RISE UP TO CEILING SPACE.

6. ALL CONDUIT ROUTED FROM DISCONNECT TO EXTERIOR HVAC UNITS SHALL BE ROUTED UNDERGROUND.

TURN UP ADJACENT TO UNIT AND MAKE TRANSITION TO SEALTITE TO SERVE UNIT. CONDUIT SHALL BE.

ROUTED CONCEALED IN WALL.

7. ALL FLUSH RECESSED OUTLET BOXES SHALL BE INSTALLED SUCH THAT FRONT EDGE OF BOX WILL NOT BE SET BACK OF THE FINISHED SURFACE MORE THAN 1/4" IN ORDER TO COMPLY WITH N.E.C. 314-20. SUPPORT

OF OUTLET BOX BY RECEPTACLE AND COVERPLATE IS NOT ACCEPTABLE.

8. ALL CONDUIT, OUTLET BOXES, AND LOW VOLTAGE CABLING SHALL BE APPROPRIATELY SUPPORTED THROUGHOUT THE PROJECT. SUPPORT OF THESE ITEMS BY CEILING GRID OR GRID SUPPORT WIRES IS NOT

ACCEPTABLE.

9. ALL EXTERIOR DISCONNECTS SHALL BE RATED NEMA 3R.

10. COORDINATE EXACT LOCATION OF ALL MECHANICAL AND PLUMBING EQUIPMENT WITH DIVISION 23…