Attachment E - API Internal Inspection Telecon Briefing Template.docx

DOCX document 14 KB Posted

Attached to
POL Tank Inspection EIE - Eielson AFB, Alaska
Solicitation number
PANNWD-24-P-0000-002757
Issued by

About this file

The provided document is a teleconference briefing template summarizing the findings from an API 653 inspection of a fuel storage tank. The inspection was performed by a company on behalf of the government under Contract No. XXXXX, Task Order XX. The findings are categorized as mandatory, short-term, or long-term, and include recommended future inspection dates for the API 653 out-of-service and in-service tank inspections, as well as additional testing. The document states that the final inspection report will be included in the close-out documentation as required by the task order.

View the file

Other files

File Type Posted
Revised EIE PWS.docx DOCX document
Revised CLIN Bid Schedule.docx DOCX document
Revised Attachment B - Fuel Storage Tank List.xlsx XLSX spreadsheet
Eielson AFB-6257 OOS Final Report.pdf PDF
Questions and Answers.docx DOCX document
Eielson AFB-6239 OOS Final Report.pdf PDF
Attachment 1 - Revised CLIN Bid Schedule.docx DOCX document
Eielson AFB-4482 OOS Final Report.pdf PDF
Eielson AFB-6259 OOS Final Report.pdf PDF
Attachment B - Revised Fuel Storage Tank List.xlsx XLSX spreadsheet
Attachment B - Fuel Storage Tank List.xlsx XLSX spreadsheet
Attachment I - API External Inspection Template.docx DOCX document
Attachment D - Monthly Contractors Progress Management and Status Report.xlsx XLSX spreadsheet
Attachment F - API Internal Inspection Template.docx DOCX document
Attachment 2 - PWS - SP-POL-CMP-INSPECT-FY24-EIE.docx DOCX document
Attachment G - Return To Service Letter.docx DOCX document
WD2015-5683-Rev 19.pdf PDF
Attachment A - General Installation Security Requirements.docx DOCX document
Attachment 3 - 52.212-1 Addendum - EIE Tank Inspection.rtf RTF text file
Combined Synopsis-Solicitation PANNWD-24-P-0000 002757.docx DOCX document
Attachment 1 - CLIN Bid Schedule - EIE Tank Inspection.docx DOCX document
Attachment C - Tank Data Sheet.xlsx XLSX spreadsheet
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

[COMPANY Name or Letter Head]

DATE

Subject: Teleconference Briefing of the Summary of Findings From the Inspection

STORAGE TANK NO. [ XXXXX]

Fuel System Inspection, [Location] Contract No. [XXXXX], Task Order [XX] Out-of-Service [API 653] Inspection

Tank [XXX] was inspected for serviceability evaluation in accordance with the requirements of [API STD 653, XX Edition, Date.]. The Inspection was performed by [Company Name] on [ddmmmyy].

The findings have been listed and categorized as follows:

A. Mandatory B. Short Term C. Long Term

RECOMMENDED FUTURE INSPECTION DATES no later than (NLT):

API 653 Out-Of-Service tank inspection[date]
API 653 In-Service tank inspection[date]
…UT Roundness…Corrosion…etc[date]

SATE REGULATIONS (N/A if Not Applicable):

[State] Regulations follow [……] State Regulations for API 653 Out-Of-Service tank inspections is NLT [date]

Final documents will be included in the close out documentation as required by the task order.

Prepared by:

[Inspectors Name] [Title] [Company] API 653 Certified Inspector No. [XXXX]