Attachment D.pdf
PDF 3 MB Posted
- Attached to
- ITB 2313
- Solicitation number
- 54512
- Issued by
- Arlington County, Union Hall CDP, Virginia
About this file
This document contains the plans and specifications for the Augusta County Service Authority (ACSA) Middle River Revised Office Complex project in Augusta County, Virginia. The project involves the construction of a 20,300 square foot multi-use office, garage, and material storage facility, as well as associated paved storage parking for equipment and large ACSA construction vehicles. The project includes site preparation, utilities, grading, and landscaping. The plans provide details on the building layout, utility plans, grading, and structural and general construction details. Estimated quantities are provided for the various utility lines, manholes, and other infrastructure components.
The document outlines the pavement sections for the various areas of the site, including light-duty concrete and asphalt for the service areas, employee parking, and main driveways/drive aisles. Additional details are provided for features such as pipe bollards, pull boxes, and generator foundations. No specific bid due date or award information is included in the plans.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Site Location
To Harrisonburg
To Staunton
Verona
WASHINGTON, D.C.
ROANOKE
RICHMOND
STAUNTON
WINCHESTER
HARRISONBURG
PROJECT
AREA
ACSA MIDDLE RIVER
REVISED OFFICE COMPLEX
AUGUSTA COUNTY, VIRGINIA
PREPARED FOR:
Augusta County Service Authority
P.O. BOX 859
Verona, Virginia 24482
SHEET INDEX
G01 TITLE SHEET
G02 NOTES & LEGEND
C01 EXISTING CONDITIONS DEMOLITION PLAN PHASE I E&S
C02 BUILDING LAYOUT & DIMENSION PLAN
C03 UTILITY PLAN
C04 OVERALL GRADING PLAN & PHASE II E&S
C05 NW GRADING
C06 SE GRADING
C07 STORM POND GRADING
C08 WATERLINE & SANITARY SEWER PROFILE
C09 STORM SEWERS & OUTFALL PROFILES
D01 STANDARD WATER UTILITY DETAILS
D01A STANDARD WATER UTILITY DETAILS
D02 STANDARD SEWER UTILITY DETAILS
D03 STANDARD SEWER UTILITY DETAILS
D04 STRUCTURAL & GENERAL DETAILS
D05 E&S DETAILS
D06 STORM DETAILS
CS COVER SHEET
TITLE SHEET
JN:
SEAL DRAWN BY:
REVIEW BY:
REVISION:
DATE:
SHEET DESCRIPTION:
20 MIDWAY PLAZA DRIVE - SUITE 100
ortz , L.L.C.
&eed BP
PHONE: (540) 394 - 3214
CHRISTIANSBURG, VIRGINIA 24073
FAX : (540) 394 - 3215
CIVIL & ENVIRONMENTAL ENGINEERS
20-10
JJM
S. BORTZ
22 OCT 2021
AUG 31 2022AUGUSTA COUNTY VIRGINIA
ACSA MIDDLE RIVER
REVISED OFFICE COMPLEX G01
PROJECT IDENTIFICATION:
MIDDLE RIVER OFFICE COMPLEX
NO ASSIGNED ADDRESS, OPPOSITE 848 LAUREL HILL RD
VERONA, VA 24482
TAX PARCEL: TMP 47A-(1)-5C
DEED BOOK REFERENCE INFORMATION: DB674 P374 & DB674 P377
OWNER OF RECORD : AUGUSTA COUNTY SERVICE AUTHORITY, A BODY CORPORATE AND POLITIC
ZONE GENERAL INDUSTRIAL
PROJECT NARRATIVE:
THIS PROJECT CONSISTS OF CONSTRUCTION OF A 20,300 SQFT MULTI USE OFFICE, GARAGE, AND MATERIAL STORAGE FACILITY AND
ASSOCIATED PAVED STORAGE PARKING FOR EQUIPMENT AND LARGE ACSA CONSTRUCTION VEHICLES. THIS BUILDING WILL BE LOCATED ON
THE SAME PARCEL AS THE MIDDLE RIVER WASTE WATER TREATMENT PLANT, ON THE OPPOSITE SIDE OF THE ACCESS DRIVE.
O
SCOTT BORTZ
DE
PR
C
IFI
TR
E
NE
OISSEF LAN
Lic. No. 032379 REENIG
NOTES & LEGEND
EXISTING BUILDING
SITE LEGEND
PROPOSED FENCE
DEMO TREE LINE PROPOSED TREE LINE
EXISTING PAVED DRIVE
EXISTING TREE LINE
EXISTING GRAVEL DRIVE
EXISTING TELEPHONE
EXISTING OVERHEAD
ELECTRICITY
EXISTING SANITARY SEWER
PROPOSED CONTOUR LINE
PROPOSED WATER LINE
PROPOSED SANITARY SEWER
PROPOSED STORM SEWER
PROPOSED BUILDING
PROPOSED SPOT SHOT
PROPOSED GRAVEL
PROPOSED PAVEMENT
PROPOSED LIGHT-DUTY PAVEMENT
GENERAL ABBREVIATIONS:
DESIGN NOTES:
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
APPROX APPROXIMATELY
ASSY ASSEMBLY
BF BUTTERFLY (VALVE)
BLDG BUILDING
BOT BOTTOM
CHEM CHEMICAL
CL CENTERLINE
CO CLEANOUT
DI DUCTILE IRON
DIA DIAMETER
DIG DIGESTER
DIP DUCTILE IRON PIPE
E EAST
EF EFFLUENT
EG EXISTING GRADE
ELEV ELEVATION
EP EDGE OF PAVEMENT
EQ EQUALIZATION
EQUIP EQUIPMENT
EX EXISTING
F&C FRAME AND COVER
FD FLOOR DRAIN
FF FINISHED FLOOR (ELEVATION)
FG FINISHED GRADE
FM FORCE MAIN
FRP FIBERGLASS REINFORCED PLASTIC
GAL GALLON
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
GRAV GRAVITY
HDLPE HIGH DENSITY LINEAR POLYETHYLENE
HP HORSEPOWER
HVAC HEATING, VENTILATION, & AIR CONDITIONING
ID INSIDE DIAMETER
INF INFLUENT
INV INVERT
LED LIGHT-EMITTING DIODE
LF LINEAR FEET
LWL LOW (MINIMUM) WATER LEVEL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MGD MILLION GALLONS PER DAY
MH MANHOLE
MIN MINIMUM
MJ MECHANICAL JOINT
N NORTH
NC NORMALLY CLOSED
NPW NON-POTABLE WATER
NPT NATIONAL PIPE THREAD (TAPER)
NTS NOT TO SCALE
NWL NORMAL (AVERAGE) WATER LEVEL
OC ON CENTER
PE POLYETHYLENE
PG PROPOSED GRADE
PROP PROPOSED
PS PUMP STATION
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
RED REDUCER
S SOUTH
SAN SANITARY
SBR SEQUENCING BATCH REACTOR
SEW SEWER
SF SILT FENCE
SQF SQUARE FOOT (FEET)
SS STAINLESS STEEL
SSE SANITARY SEWER EASEMENT
STA STATION
STR STRUCTURE
SUP SUPERNATANT
TOS TOP OF SLAB
TOW TOP OF WALL
TYP TYPICAL
UV ULTRAVIOLET (DISINFECTION)
WAS WASTE ACTIVATED SLUDGE
W WEST
W/ WITH
WSE WATER SURFACE ELEVATION
YR YEAR
PARKING SIGNS FOR THE DISABLED
EROSION CONTROL LEGEND
CIVIL GENERAL NOTES:
STANDARD NOTES
EXISTING CONTOUR LINE
EXISTING WATER LINE
EXISTING PROPERTY LINE
EXISTING UNDERGROUND
ELECTRICITY
PROPOSED CONCRETE SIDEWALK
BUILDING SETBACKS
PROPOSED DITCH
EROSION CONTROL TABLE OF ESTIMATED QUNATITIES
DESCRIPTION QUANTITY UNIT
SILT FENCE 2600 LF
DIVERSION DIKE 180 LF
STORMWATER CONVEYANCE CHANNEL 0 LF
INLET PROTECTION 7 EA
CULVERT OUTLET PROTECTION 2 EA
CONSTRUCTION ENTRANCE 1 EA
SEDIMENT BASIN 1 EA
BM MATTING 300 LF
TABLE OF ESTIMATED QUANTITIES
DESCRIPTION QUANTITY UNIT
CLASS 52 DIP WATER LINE 830 LF
SDR 35 SANITARY SEWER 1300 LF
STORM SEWER 1250 LF
SANITARY MANHOLE 1 EA
SANITARY MANHOLE DEPTH 6.7
VERTICAL
FEET
STORM MANHOLE 7 EA
STORM MANHOLE DEPTH 32.2
VERTICAL
FEET
FIRE HYDRANT ASSEMBLY 1 EA
8" GATE VALVE 1 EA
METER BOXES 1 EA
CLEANOUTS 32 EA
ELECTRICAL PULL BOX 13 EA
PROPOSED CONDUIT BANK
UNDERGROUND
ELECTRICITY/ COM. CABLES
PROPOSED GAS
JN:
SEAL DRAWN BY:
REVIEW BY:
REVISION:
DATE:
SHEET DESCRIPTION:
20 MIDWAY PLAZA DRIVE - SUITE 100
ortz , L.L.C.
&eed BP
PHONE: (540) 394 - 3214
CHRISTIANSBURG, VIRGINIA 24073
FAX : (540) 394 - 3215
CIVIL & ENVIRONMENTAL ENGINEERS
20-10
JJM
S. BORTZ
22 OCT 2021
AUG 31 2022AUGUSTA COUNTY VIRGINIA
ACSA MIDDLE RIVER
REVISED OFFICE COMPLEX G02
O
SCOTT BORTZ
DE
PR
C
IFI
TR
E
NE
OISSEF LAN
PROPOSED BOLLARD
S T
R A
W
S
H E
D
T O
P S
O I L
B
I N
GRAVEL
BIN
COLD
PATCH
EQUIPMENT SHED
32'X80'
S P
O I L
D
I R
T
T O
P
S
O I L
S
T O
C K
P
I L E
A
R E
A
PIPE RACK SYSTEM 80' L
EX. WWTP
625' TO ROUTE 612
ACCESS DRIVE
EX. WATER
BLDG
EX.PARKING
EX.
BLDG
MIDDLE RIVER OFFICE BUILDING
FF = 1246.0
2- 40 CU YD
DUMPSTERS
22'X8'
EX. CONTROL
BLDG
BUILDING LAYOUT &
DIMENSION PLAN
JN:
SEAL DRAWN BY:
REVIEW BY:
REVISION:
DATE:
SHEET DESCRIPTION:
20 MIDWAY PLAZA DRIVE - SUITE 100
ortz , L.L.C.
&eed BP
PHONE: (540) 394 - 3214
CHRISTIANSBURG, VIRGINIA 24073
FAX : (540) 394 - 3215
CIVIL & ENVIRONMENTAL ENGINEERS
20-10
JJM
S. BORTZ
22 OCT 2021
AUG 31 2022AUGUSTA COUNTY VIRGINIA
ACSA MIDDLE RIVER
REVISED OFFICE COMPLEX C02
O
SCOTT BORTZ
DE
PR
C
IFI
TR
E
NE
OISSEF LAN
R A
W
S
H E
D
T O
P S
O I L
B
I N
GRAVEL
BIN
COLD
PATCH
EQUIPMENT SHED
32'X80'
S P
O I L
D
I R
T
T O
P
S
O I L
S
T O
E
A
PIPE RACK SYSTEM 80' L
EX. WWTP
625' TO ROUTE 612
ACCESS DRIVE
EX. WATER
BLDG
EX.PARKING
EX.
BLDG
MIDDLE RIVER OFFICE BUILDING
FF = 1246.0
2- 40 CU YD
DUMPSTERS
22'X8'
EX. CONTROL
BLDG
EXISTING SEWER
O
SCOTT BORTZ
DE
PR
C
IF
IT
RE
NE
OISSEF LAN
Lic. No. 032379 REENIG
UTILITY PLAN
JN:
SEAL DRAWN BY:
REVIEW BY:
REVISION:
DATE:
SHEET DESCRIPTION:
20 MIDWAY PLAZA DRIVE - SUITE 100
ortz , L.L.C.
&eed BP
PHONE: (540) 394 - 3214
CHRISTIANSBURG, VIRGINIA 24073
FAX : (540) 394 - 3215
CIVIL & ENVIRONMENTAL ENGINEERS
20-10
JJM
S. BORTZ
22 OCT 2021
AUG 31 2022AUGUSTA COUNTY VIRGINIA
ACSA MIDDLE RIVER
REVISED OFFICE COMPLEX C03
ELECTRICAL NOTES
R A
W
S
H E
D
T O
P S
O I L
B
I N
GRAVEL
BIN
COLD
PATCH
EQUIPMENT SHED
32'X80'
S P
O I L
D
I R
T
T O
P
S
O I L
S
T O
E
A
PIPE RACK SYSTEM 80' L
EX. WWTP
625' TO ROUTE 612
ACCESS DRIVE
EX. WATER
BLDG
EX.PARKING
EX.
BLDG
MIDDLE RIVER OFFICE BUILDING
FF = 1246.0
2- 40 CU YD
DUMPSTERS
22'X8'
EX. CONTROL
BLDG
O
SCOTT BORTZ
DE
PR
C
IF
IT
RE
NE
OISSEF LAN
Lic. No. 032379 REENIG
OVERALL GRADING PLAN &
PHASE II E&S
JN:
SEAL DRAWN BY:
REVIEW BY:
REVISION:
DATE:
SHEET DESCRIPTION:
20 MIDWAY PLAZA DRIVE - SUITE 100
ortz , L.L.C.
&eed BP
PHONE: (540) 394 - 3214
CHRISTIANSBURG, VIRGINIA 24073
FAX : (540) 394 - 3215
CIVIL & ENVIRONMENTAL ENGINEERS
20-10
JJM
S. BORTZ
22 OCT 2021
AUG 31 2022AUGUSTA COUNTY VIRGINIA
ACSA MIDDLE RIVER
REVISED OFFICE COMPLEX C04
LIGHT DUTY CONCRETE SERVICE AREA SECTION
CONCRETE EXPANSION AND CONTROL JOINTS
PAVEMENT SECTIONS
PAVEMENT SECTIONS
PAVEMENT SECTIONS
(EMPLOYEE PARKING)
GRAVEL AREAS
(SIDEWALK & HVAC PADS)
DRAWING NUMBER: G-7 PAGE: 1 OF 1
TYPICAL PAVEMENT PATCH
FOR PRIVATE PAVED ROADS
AUGUSTA COUNTY SERVICE AUTHORITY
VERONA, VIRGINIA
REVISED: MAR. 2021
SCALE: NTS DRAWN BY: ACSA
DATE: NOV. 2014
AUGUSTA COUNTY SERVICE AUTHORITY
VERONA, VIRGINIA
SCALE: NTS DRAWN BY: ACSA
DATE: NOV. 2020 REVISED:
TYPICAL PIPE BOLLARD
DRAWING NUMBER: G-8 PAGE: 1 OF 1
PULL BOX
MEDIUM DUTY CONCRETE SERVICE AREA SECTION
(BUILDING APRON)
HEAVY DUTY CONCRETE SERVICE AREA SECTION
(LOADING DOCK)
GENERATOR FOUNDATION DETAIL
STRUCTURAL & GENERAL
DETAILS
JN:
SEAL DRAWN BY:
REVIEW BY:
REVISION:
DATE:
SHEET DESCRIPTION:
20 MIDWAY PLAZA DRIVE - SUITE 100
ortz , L.L.C.
&eed BP
PHONE: (540) 394 - 3214
CHRISTIANSBURG, VIRGINIA 24073
FAX : (540) 394 - 3215
CIVIL & ENVIRONMENTAL ENGINEERS
20-10
JJM
S. BORTZ
22 OCT 2021
AUG 31 2022AUGUSTA COUNTY VIRGINIA
ACSA MIDDLE RIVER
REVISED OFFICE COMPLEX D04
O
SCOTT BORTZ
DE
PR
C
IFI
TR
E
NE
OISSEF LAN
Lic. No. 032379 REENIG
(VISITOR PARKING)
LIGHT DUTY ASPHALT PAVEMENT SECTION
(MAIN DRIVEWAYS AND DRIVE AISLES)
HEAVY DUTY ASPHALT PAVEMENT SECTION
| MR Plans for Bid 08312022 1 |
| MR Plans for Bid 08312022 2 |
| MR Plans for Bid 08312022 4 |
| MR Plans for Bid 08312022 5 |
| MR Plans for Bid 08312022 6 |
| MR Plans for Bid 08312022 16 |
File details come from the government source that posted it. Updated .