Attachment_D_C1990_Plans.PDF
PDF 2 MB Posted
- Attached to
- GEE CREEK EROSION CONTROL PROJECT – PHASE I (SHEET PILING) State and local contract opportunity
- Solicitation number
- ITB-2017-0177-0-2017/MO
- Issued by
- Seminole County, Florida
About this file
The document is a comprehensive set of engineering plans and technical specifications for the Gee Creek Erosion Control Project - Phase I (Sheet Piling) prepared by CPH, Inc. for the City of Casselberry, located in Seminole County, Florida. The project involves installing approximately 170 linear feet of PZ35 steel sheet piling along North Winter Park Drive, with sheet piles ranging from 37 feet long and installed from elevation 13.00 to 50.75. The project includes sheet pile installation, concrete cap construction, erosion control measures, maintenance of traffic, and site restoration, with construction to be performed in compliance with Florida Department of Transportation (FDOT) standard specifications.
The contract requires the selected contractor to perform at least 55% of the work with their own forces and includes specific requirements for site preparation, utility protection, noise control, and environmental preservation. Road closures are permitted for two five-day periods, with traffic maintenance provisions requiring one lane to remain open during working hours and full weekend road access. The project involves careful environmental considerations, including installing floating turbidity barriers, silt fencing, and preparing a Stormwater Pollution Prevention Plan (SWPPP) in accordance with EPA NPDES regulations. The estimated project scope involves sheet pile installation, concrete work, grading, sodding disturbed areas, and comprehensive erosion control measures.
View the file
Other files for this state and local contract opportunity
| File | Type | Posted |
|---|---|---|
| Addendum_No._1.PDF | ||
| Attachment_W_-_FDOT_Section_108.PDF | ||
| Attachment_V_Standard_Construction_Agreement.PDF | ||
| Attachment_U_Geotechnical_Engineering_Report.PDF | ||
| Bid_Solicitation_Document.PDF |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C
I T
Y
O
F
C
A S
S E
L B
E R
R Y
G
E
E
K
O
S I O
N
C
O N
T R
O L
P
O
J E
T
H A
S
H E
T
I L I N
G
Gee Creek Erosion Control Project
CITY OF CASSELBERRY
SHEET INDEX
VICINITY MAP
C I T
Y
O
F
C
A S
S
E
L
B
E
R
R Y
I
N
C
1 9
Phase 1 - Sheet Piling
CITY OFFICIALS:
April 2017
LAKE KATHRYN
S
E
M
I N
O
A
B
U
L E
V
A
R
D
D r a w i n g n a m e
J C
C i v i l D
W G
D e s i g n C
C o v e r d w g p r m d h o l l a n d
PROJECT NO. C1990
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Surveyors
Traffic/Transportation
A Full Service A & E Firm
1117 East Robinson Street, Orlando, FL 32801
Phone: 407.425.0452
Arch. Lic. No. AA2600926
Landscape Lic. No. LC0000298
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
L
A
T
H
R
Y
N
I
R
U
PROJECT
LOCATION
Sheet No.
C-1
W I N
T E
R
P
A R
K
D
R
C-1
C-2
C-3
C-4
C-5
COVER
GENERAL NOTES
SITE PLAN
CROSS SECTIONS
DETAILS
MAYOR/COMMISSIONER:
CITY COMMISSIONER SEAT 1:
CITY COMMISSIONER SEAT 2:
CITY COMMISSIONER SEAT 3:
CITY COMMISSIONER SEAT 4:
CITY MANAGER:
PUBLIC WORKS DIRECTOR:
CITY ENGINEER:
CHARLENE GLANCY
ANTHONY ARAMENDIA
ANDREW MEADOWS
SANDRA SOLOMON
BILL HUFFORD
JAMES NEWLON
MARK GISCLAR
KELLY BROCK
G
E
N
100% DRAWINGS
GENERAL NOTES
1. FOR IDENTIFICATION OF CONTRACTUAL AGREEMENTS, THIS SET OF DRAWINGS IS DATED MAY 2017. ANY REVISIONS THEREAFTER WILL
BE DATED AND NOTED ON THE AFFECTED DRAWING(S).
2. THE LOCATIONS OF EXISTING PIPING AND UTILITIES, SUCH AS GAS WATER LINES, RAW SEWAGE LINES, SLUDGE LINES, DRAIN LINES, TELEPHONE, CABLE TV, UNDERGROUND ELECTRIC CABLES, ETC., AS SHOWN ON THE DRAWINGS, HAVE BEEN DETERMINED FROM THE
BEST AVAILABLE INFORMATION, AND ARE GIVEN FOR THE CONVENIENCE OF THE CONTRACTOR. THE ENGINEER ASSUMES NO
RESPONSIBILITY FOR ACCURACY. PRIOR TO CONSTRUCTION AND THE ORDERING OF MATERIALS, THE CONTRACTOR SHALL FIELD
VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES. THE CONTRACTOR SHALL NOTIFY THE VARIOUS UTILITIES AND MAKE THE
NECESSARY ARRANGEMENTS FOR RELOCATION OF THESE UTILITIES. ANY DELAY, INCONVENIENCE, OR EXPENSE CAUSED BY THE
RELOCATION OF THE VARIOUS UTILITIES SHALL BE INCIDENTAL TO THE CONTRACT AND NO EXTRA COMPENSATION WILL BE ALLOWED.
3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN IN SERVICE, ALL EXISTING PIPING ENCOUNTERED DURING
CONSTRUCTION UNLESS OTHERWISE INDICATED IN THE DRAWINGS. ANY PIPING WHICH CAN BE REMOVED DURING CONSTRUCTION
WITHOUT UNDUE INTERRUPTION OF SERVICE MAY BE REMOVED AND REPLACED BY THE CONTRACTOR WITH THE PERMISSION OF THE
ENGINEER AND OWNER.
4. THE CONTRACTOR SHALL STORE CONSTRUCTION EQUIPMENT AND MATERIALS ONLY IN THOSE AREAS DESIGNATED BY THE ENGINEER
AND OWNER. SECURITY OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
5. WHERE PROPERTY MARKERS, SECTION CORNERS, SURVEY MARKS, SUCH AS STONES, PIPES OR OTHER MONUMENTS ARE
ENCOUNTERED, THE ENGINEER AND OWNER ARE TO BE NOTIFIED BEFORE THEY ARE MOVED. THE MARKER SHALL BE PROTECTED AND
PRESERVED UNTIL THE ENGINEER AND OWNER, AUTHORIZED SURVEYOR OR AGENT HAS WITNESSED OR REFERENCED THEIR
LOCATIONS. THE MARKERS SHALL BE REPLACED BY AN APPROVED SURVEYOR AT THE CONTRACTORS EXPENSE.
6. TYPICAL DETAILS AS SHOWN ARE TO ILLUSTRATE THE ENGINEER'S INTENT AND ARE NOT PRESENTED AS A SOLUTION TO ALL
CONSTRUCTION PROBLEMS ENCOUNTERED IN THE FIELD. THE CONTRACTOR MAY ALTER THE METHOD OF CONSTRUCTION TO SUIT
FIELD CONDITIONS, PROVIDING HE SUBMITS A PROPOSAL FOR AN ALTERNATE METHOD TO ENGINEER FOR APPROVAL AND USES
MATERIALS AS DESIGNATED IN THE SPECIFICATIONS.
7. ALL TREES, SHRUBS, MAILBOXES, LANDSCAPING, SOD, ETC., ALONG THE LINES OF CONSTRUCTION SHALL BE PROTECTED WHERE
POSSIBLE. THESE ITEMS SHALL BE TEMPORARILY RELOCATED, IF NECESSARY, AND REPLACED TO THEIR ORIGINAL LOCATION UPON
COMPLETION OF CONSTRUCTION.
8. ALL EXCESS CLEAN FILL SHALL BE DISPOSED OF AS DIRECTED BY THE OWNER.
9. THE OWNER SHALL PROVIDE THE SERVICES OF A TESTING LABORATORY TO DETERMINE WHETHER THE REQUIREMENTS FOR
MATERIALS SPECIFICATIONS ARE MET.
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY TEMPORARY CONTROLS AND/OR STRUCTURES REQUIRED TO MAINTAIN SUITABLE
AND SAFE WORKING CONDITIONS AT ALL TIMES. SUCH ITEMS SHALL BE REMOVED ONCE THAT PORTION OF WORK HAS BEEN
COMPLETED.
11. CHAPTER 553-851 OF THE FLORIDA STATUTE'S REQUIRES THAT AN EXCAVATOR NOTIFY ALL GAS UTILITIES A MINIMUM OF TWO (2)
WORKING DAYS PRIOR TO EXCAVATING.
12. UPON COMPLETION OF THE PROJECT, THE PROJECT AREA SHALL BE RESTORED TO ITS ORIGINAL CONDITION AND TO THE
SATISFACTION OF THE OWNER. ALL DAMAGED PRIVATE PROPERTY SHALL BE RESTORED TO ORIGINAL OR BETTER CONDITION.
13. THE CONTRACTOR SHALL PROVIDE VERTICAL AND HORIZONTAL "AS-BUILT" DRAWINGS FOR ALL CONSTRUCTED STRUCTURES/PILING
SIGNED AND SEALED BY A STATE OF FLORIDA LICENSED SURVEYOR.
CONCRETE:
ALL CONCRETE FILL SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2,500 P.S.I. SEE OTHER NOTES FOR STRUCTURAL CONCRETE.
PERMITS AND PERMIT REQUIREMENTS:
THE CONTRACTOR SHALL OBTAIN, FROM THE CITY, COPIES OF ALL REGULATORY AGENCY PERMITS AND LOCAL AGENCY PERMITS. THE
CONTRACTOR SHALL BE EXPECTED TO REVIEW AND ABIDE BY ALL THE REQUIREMENTS AND LIMITATIONS SET FORTH IN THE PERMITS.
LAYOUT AND CONTROL:
THE CONTRACTOR SHALL USE THE GEOMETRY PROVIDED ON THE CONSTRUCTION PLANS. BENCHMARK INFORMATION IS SHOWN ON THE
PLANS. ANY DISCREPANCIES BETWEEN FIELD MEASUREMENTS AND CONSTRUCTION PLAN INFORMATION SHALL BE BROUGHT TO THE
ATTENTION OF THE ENGINEER IMMEDIATELY.
OWNER/ OPERATOR:
THE ENTITY THAT WILL OWN, OPERATE AND MAINTAIN THE FACULTIES SHOWN ON THE PLANS IS THE CITY OF CASSELBERRY. THE
CONTRACTOR SHALL MEET ALL THE REQUIREMENTS OF THIS ENTITY.
COORDINATION WITH SCHOOL BUS ROUTE:
CONTRACTOR SHALL COORDINATE TRAFFIC CLOSURES CLOSELY WITH THE SEMINOLE COUNTY SCHOOL BOARD TRANSPORTATION
DIVISION.
SOILS REPORT:
A COPY OF THE SOILS REPORT IS INCLUDED IN THE CONTRACT DOCUMENTS AS APPENDIX A. THE CONTRACTOR SHALL ABIDE BY ALL
RECOMMENDATIONS CONTAINED THEREIN. THE REPORT WAS PREPARED BY TERRACON.
TRENCHING:
THE CONTRACTOR SHALL RECOGNIZE AND ABIDE BY ALL OSHA EXCAVATION SAFETY STANDARDS, INCLUDING THE FLORIDA TRENCH ACT
(90-96, LAWS OF FLORIDA). ANY MATERIAL, CONSTRUCTION METHODS, OR MATERIAL COST TO COMPLY WITH THESE LAWS SHALL BE
INCIDENTAL TO THE CONTRACT.
PUBLIC SAFETY:
THE CONTRACTOR SHALL TAKE ALL NECESSARY SAFETY MEASURES AND PRECAUTIONS TO PROTECT THE LOCAL RESIDENTS AND GENERAL
PUBLIC THROUGHOUT THE DURATION OF HIS WORK.
MATERIAL SPECIFICATIONS - REINFORCED CONCRETE PIPE:
REINFORCED CONCRETE PIPE (RCP) SHALL BE CLASS III WITH RUBBER GASKET JOINTS. RCP SHALL CONFORM TO FDOT STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, SECTION 449. RUBBER GASKETS SHALL CONFORM TO SECTION 942.
ALL MATERIALS AND CONSTRUCTION METHODS ARE TO BE IN ACCORDANCE WITH FDOT STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION, SECTION 400 (CONCRETE STRUCTURES) AND THE APPLICABLE FDOT INDEX NUMBER DETAIL AS SHOWN IN FDOT ROADWAY
AND TRAFFIC DESIGN STANDARDS (LATEST EDITION).
ALL OTHER RELATED ITEMS REQUIRED FOR THE CONSTRUCTION OF THE STORM SYSTEM (OUTFALL PROTECTION, POLLUTION CONTROL, ETC.) ARE TO BE IN ACCORDANCE WITH DETAILS SHOWN ON THE CONSTRUCTION PLANS, FDOT ROADWAY AND BRIDGE CONSTRUCTION.
WETLAND/ OUTFALL PROTECTION:
ALL OUTFALLS SHALL BE CONSTRUCTED SO AS TO NOT CREATE EROSION PROBLEMS OR DESTRUCTION OF WETLANDS. ALL OUTFALLS
SHALL BE STABILIZED OR EROSION CONTROL MEASURES INSTALLED PRIOR TO USE OF THE STORM SYSTEM. THE CONTRACTOR SHALL
CONTINUOUSLY MAINTAIN EROSION CONTROL MEASURES THROUGHOUT CONSTRUCTION.
WATER BODY PROTECTION:
THE CONTRACTOR SHALL INSTALL TYPE II FLOATING TURBIDITY BARRIERS PARALLEL TO AND ON EACH SIDE OF THE WORK TO PREVENT THE
INTRODUCTION OF SILT AND OTHER CONTAMINANTS INTO THE CHANNEL WHILE MAINTAINING FLOW THROUGH THE CHANNEL. INSTALL IN
ACCORDANCE WITH FDOT INDEX No. 103.
INSTALL TYPE III SILT FENCE IN LOCATIONS AS SHOWN ON THE PLANS. SEE "EROSION CONTROL PLAN" THIS SHEET.
EARTHWORK:
THE CONTRACTOR SHALL PERFORM HIS OWN INVESTIGATIONS AND CALCULATIONS AS NECESSARY TO ASSURE HIMSELF OF EARTHWORK
QUANTITIES. THERE IS NO IMPLICATION THAT EARTHWORK BALANCES AND THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY IMPORT
FILL NEEDED, OR FOR REMOVAL AND DISPOSAL OF EXCESS MATERIALS.
R/W AND CONSTRUCTION AREA RESTORATION:
ALL AREAS WITHIN THE RIGHT-OF-WAY AND THE CONSTRUCTION AREA SHALL BE FINISH GRADED WITH A SMOOTH TRANSITION INTO
EXISTING GROUND. ALL SWALES SHALL BE STABILIZED IMMEDIATELY AFTER FINAL GRADING. ALL DISTURBED AREAS SHALL BE STABILIZED
(SODDED) AFTER FINAL GRADING IN ACCORDANCE WITH THE CONSTRUCTION PLANS PRIOR TO FINAL INSPECTION. ALL GRASSING (SOD)
SHALL BE MAINTAINED BY THE CONTRACTOR UNTIL FINAL ACCEPTANCE BY THE OWNER/OPERATOR.
MATERIAL STORAGE / DEBRIS REMOVAL:
MATERIALS SHALL BE STOCKPILED SEPARATELY AS TO USABLE (NON-ORGANIC) FILL STOCKPILES AND NON-USABLE ORGANIC (MUCK)
STOCKPILES IF MUCK IS ENCOUNTERED. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL AND LEGAL DISPOSAL OF ALL
UNSUITABLE MATERIALS FROM THE SITE.
FILL MATERIAL:
ALL FILL MATERIALS SHALL CONTAIN NO MUCK, STUMPS, ROOTS, BRUSH, VEGETATIVE MATTER, RUBBISH OR OTHER MATERIAL THAT WILL
NOT COMPACT INTO A SUITABLE AND ENDURING BACKFILL.
COMPACTION:
FILL MATERIALS PLACED UNDER ROADWAYS SHALL BE COMPACTED TO AT LEAST 98% MAXIMUM DENSITY AS SPECIFIED IN AASHTO T-180.
ALL OTHER FILL AREAS ARE TO BE COMPACTED TO AT LEAST 95% MAXIMUM DENSITY AS SPECIFIED IN AASHTO T-180. FILL MATERIALS SHALL
BE PLACED AND COMPACTED IN A MAXIMUM OF 12" LIFTS. REFER TO SOILS REPORT FOR ADDITIONAL INFORMATION. THE CONTRACTOR
SHALL PROVIDE THE ENGINEER AND OWNER WITH ALL (PASSING AND FAILING) TESTING RESULTS. RESULTS SHALL BE PROVIDED ON A
TIMELY AND REGULAR BASIS PRIOR TO CONTRACTOR'S PAY REQUEST SUBMITTAL.
SURFACE DRAINAGE:
THE CONTRACTOR SHALL BE EXPECTED, AT THE END OF THE DAY, TO HAVE THE SITE GRADED IN SUCH A WAY AS TO NOT CAUSE ANY
ADVERSE IMPACT FROM RUNOFF OR SILTATION TO ANY ADJACENT PROPERTIES. SILTATION BARRIERS SHALL BE MAINTAINED AND
REPAIRED IF REQUIRED AT THE END OF EACH WORKING DAY. GRADING SHOWN ON THESE PLANS ARE PROVIDED TO THE CONTRACTOR TO
EXPRESS THE GENERAL GRADING INTENT OF THE PROJECT. THE CONTRACTOR SHALL BE EXPECTED TO GRADE THE ENTIRE RIGHT-OF-WAY
TO PROVIDE POSITIVE DRAINAGE IN ALL AREAS THROUGHOUT THE SITE. SMOOTH TRANSITIONS SHALL BE PROVIDED BETWEEN CONTOURS
OR SPOT ELEVATIONS AS SHOWN ON THE PLANS TO ACCOMPLISH THE GRADING INTENT. ALL SLOPES SHALL BE STABILIZED IMMEDIATELY
AFTER FINAL GRADING HAS BEEN COMPLETED. CONTRACTOR SHALL NOTIFY OWNER AND ENGINEER PRIOR TO DEMOBILIZATION OF
GRADING EQUIPMENT TO DETERMINE THAT THE GRADING INTENT HAS BEEN ACHIEVED.
TREES:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF TREE LIMBS AND TREES AS REQUIRED FOR SHEET PILE INSTALLATION.
REMOVAL OF TREES SHALL REQUIRE THE PRIOR APPROVAL OF THE OWNER.
NOISE CONTROL:
THE CONTRACTOR SHALL MAINTAIN A NOISE LEVEL LESS THAN 95 dB (A-WEIGHTED, SLOW RESPONSE) AT THE PROPERTY LINE BETWEEN
THE HOURS OF 8:00 a.m. AND 5:00 p.m. THE CONTRACTOR SHALL MAINTAIN A NOISE LEVEL LESS THAN 5 dB OVER AMBIENT NOISE LEVEL
(A-WEIGHTED, SLOW RESPONSE) AT THE PROPERTY LINE BETWEEN THE HOURS OF 7:00 a.m. TO 8:00 a.m. AND 5:00 p.m. TO 6:00 p.m.
METHODS TO MAINTAIN NOISE WITHIN ACCEPTABLE LIMITS SHALL INCLUDE BUT NOT BE LIMITED TO TEMPORARY NOISE BARRIERS, ENCLOSURES FOR EQUIPMENT, MUFFLERS, ETC. ANY WORKER NOISE DURING HOURS OUTSIDE THESE TIME FRAMES SHALL REQUIRE
PRIOR APPROVAL.
CONTRACTOR LAY-DOWN AREA:
THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR A SUITABLE LAY-DOWN AREA AT THE CONSTRUCTION SITE. THE
CONTRACTOR SHALL BE REQUIRED TO KEEP THE AREA SAFE AND FREE FROM HAZARDS TO THE PUBLIC.
THE CITY OWNS PROPERTY APPROXIMATELY 1500 FEET NORTH OF THE INTERSECTION OF NORTH WINTER PARK DRIVE AND GEE CREEK
LANE. THE PROPERTY IS LOCATED AT THE SOUTHEAST CORNER OF BELLE AVENUE AND N. WINTER PARK DRIVE. THIS IS THE PREFERRED
SITE. THIS AREA IS AVAILABLE FOR A CONSTRUCTION LAY-DOWN SITE. CONTRACTOR SHALL PROVIDE TEMPORARY FENCING AND
SECURITY AS THE CONTRACTOR DEEMS NECESSARY TO PROTECT HIS EQUIPMENT AND MATERIALS. CONTRACTOR SHALL RESTORE THE
AREA USED AS A LAY-DOWN AREA TO "PRE-USE" CONDITION OR BETTER. ADDITIONAL SITES ARE AVAILABLE AND CAN BE DISCUSSED WITH
THE OWNER AFTER AWARD OF THE CONTRACT. BIDS SHALL BE BASED ON THE PREFERRED SITE. THE CITY HAS LIMITED ENCLOSED
STORAGE AREA AT THEIR PUBLIC WORKS COMPOUND ON 7TH STREET. THIS SITE IS FENCED AND LOCKED OUTSIDE NORMAL WORKING
HOURS (7 AM TO 5 PM, MONDAY THRU THURSDAY).
SOD:
ALL DISTURBED AREAS SHALL BE SODDED WITH BAHIA SOD.
EROSION CONTROL PLAN:
AN EROSION CONTROL PLAN SHALL BE PREPARED BY THE CONTRACTOR AND SUBMITTED TO THE CITY'S ENGINEER FOR APPROVAL PRIOR
TO THE PRE-CONSTRUCTION MEETING. THE CONTRACTOR SHALL EXECUTE ALL MEASURES NECESSARY TO LIMIT THE TRANSPORT OF
SEDIMENTS OUTSIDE THE LIMITS OF THE PROJECT TO THE VOLUME AND AMOUNT AS THAT ARE EXISTING PRIOR TO THE COMMENCEMENT
OF CONSTRUCTION. THIS CONDITION WILL BE SATISFIED FOR THE TOTAL ANTICIPATED CONSTRUCTION PERIOD. PROVISION MUST BE MADE
TO PRESERVE THE INTEGRITY AND CAPACITY OF CHECK WEIRS, SEDIMENT BASINS, SLOPE DRAINS, GRADING PATTERNS, ETC. REQUIRED TO
MEET THIS PROVISION THROUGHOUT THE LIFE OF THE CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE HAY BALES, SILT BARRIERS, TEMPORARY GRASSING, ETC. AS REQUIRED TO FULLY COMPLY WITH THE INTENT OF THIS SPECIFICATION.
1. STOCKPILING MATERIAL
NO EXCAVATED MATERIAL SHALL BE STOCKPILED IN SUCH A MANNER AS TO DIRECT RUNOFF DIRECTLY OFF THE PROJECT SITE OR INTO
ANY ADJACENT WATER BODY OR STORMWATER COLLECTION FACILITY.
2. EXPOSED AREA LIMITATION
THE SURFACE AREA OF OPEN, RAW ERODABLE SOIL EXPOSED BY CLEARING AND GRUBBING OPERATIONS OR EXCAVATION AND FILLING
OPERATIONS SHALL BE CONTROLLED, SO THAT THIS OPERATION WILL NOT SIGNIFICANTLY AFFECT OFFSITE DEPOSIT SEDIMENTS.
3. INLET PROTECTION
INLETS AND CATCH BASINS SHALL BE PROTECTED FROM SEDIMENT LADEN STORMWATER RUNOFF UNTIL THE COMPLETION OF THE ALL
CONSTRUCTION OPERATIONS THAT MAY CONTRIBUTE SEDIMENT TO THE INLET.
4. TEMPORARY SEEDING
AREAS OPENED BY CONSTRUCTION OPERATIONS THAT ARE NOT ANTICIPATED TO BE DRESSED OR RECEIVE FINAL GRASSING
TREATMENT WITHIN THIRTY (30) DAYS SHALL BE SEEDED WITH A QUICK GROWING GRASS SPECIES WHICH WILL PROVIDE AN EARLY
COVER, DURING THE SEASON IN WHICH IT IS PLANTED. TEMPORARY SEEDING SHALL BE CONTROLLED SO AS TO NOT ALTER OR
COMPETE WITH PERMANENT GRASSING. THE RATE OF SEEDING SHALL BE 30 POUNDS PER ACRE.
5. TEMPORARY SEEDING AND MULCHING
SLOPES STEEPER THAN 6:1 THAT FALL WITHIN THE CATEGORY ESTABLISHED IN 4 ABOVE, SHALL ADDITIONALLY RECEIVE MULCHING OF
APPROXIMATELY TWO (2) INCHES, LOOSE MEASURE, OF MULCH MATERIAL CUT INTO THE SOIL OF THE SEEDED AREA TO A DEPTH OF
FOUR (4) INCHES.
6. TEMPORARY GRASSING
THE SEEDED OR SEEDED AND MULCHED AREA(S) SHALL BE ROLLED AND WATERED AS REQUIRED TO ASSURE OPTIMUM GROWING
CONDITIONS FOR THE ESTABLISHMENT OF A GOOD GRASS COVER.
7. TEMPORARY RE-GRASSING
IF, AFTER 14 DAYS, THE TEMPORARY GRASSED AREAS HAVE NOT ATTAINED A MINIMUM OF 75% GOOD GRASS COVER, THE AREA WILL BE
REWORKED AND ADDITIONAL SEEDS APPLIED TO ESTABLISH THE DESIRED VEGETATION COVER.
8. MAINTENANCE
ALL FEATURES OF THE PROJECT SHALL BE CONSTRUCTED TO PREVENT EROSION AND SEDIMENT AND SHALL BE MAINTAINED DURING
THE LIFE OF THE CONSTRUCTION SO AS TO FUNCTION PROPERLY WITHOUT THE TRANSPORT OF SEDIMENTS OUTSIDE THE LIMITS OF
THE PROJECT.
TEMPORARY SILT FENCES AND STAKED SILT BARRIERS, SHALL BE IN ACCORDANCE WITH FDOT STANDARD SPECIFICATION, SECTION 104
AND SECTION 985.
THE CONTRACTOR SHALL PREPARE A STORM WATER POLLUTION PREVENTION PLAN (SWPPP) IN ACCORDANCE WITH THE EPA NPDES
(NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM) REGULATIONS PRIOR TO CONSTRUCTION. THE CONTRACTOR MUST ALSO
PREPARE AND SUBMIT A NOTICE OF INTENT (NOI) FORM TO FDEP, 48 HOURS PRIOR TO COMMENCING CONSTRUCTION.
UNDER PROVISIONS OF THE CLEAN WATER ACT.
OPERATOR(S) OF CONSTRUCTION SITES, PURSUANT TO CONDITIONS OF THE NPDES PERMIT, MUST SUBMIT A NOI TO OBTAIN COVERAGE
UNDER THE NPDES STORM WATER CONSTRUCTION GENERAL PERMIT.
NOI'S MUST BE SENT TO THE FOLLOWING ADDRESS. NPDES STORMWATER PROGRAM
2600 BLAIR STONE ROAD
MAIL STATION 2500
TALLAHASSEE, FL 32399
PHONE: (850) 245-7522
EROSION CONTROL MEASURES SHALL CONFORM WITH SECTION 104 OF FLORIDA DEPARTMENT OF TRANSPORTATION, STANDARD
SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (2017).
CONSTRUCTION SPECIFICATION - SHEET PILING
1. SCOPE
THE WORK CONSISTS OF FURNISHING AND INSTALLING THE SHEET PILING.
2. MATERIAL
PILES SHALL BE STEEL PILING - PZ35 OR EQUAL.
3. SITE PREPARATION
ALL SITE PRELIMINARY PREPARATION SHALL BE COMPLETED BEFORE THE PILES ARE DRIVEN.
4. PROTECTION OF PILE HEADS
THE HEADS OF ALL PILES SHALL BE PROTECTED DURING DRIVING BY SUITABLE CAPS, RINGS, HEADS, BLOCKS, MANDRELS, AND OTHER
DEVICES.
5. PILES, GENERAL
THE CONTRACTOR SHALL NOTIFY THE ENGINEER BEFORE PILE DRIVING OPERATION COMMENCES. SUCH NOTICE SHALL BE FAR
ENOUGH IN ADVANCE, A MINIMUM OF 48 HOURS, TO PROVIDE THE ENGINEER ADEQUATE TIME TO BE PRESENT FOR THE DRIVING
OPERATIONS. PILES SHALL BE DRIVEN ONLY IN THE PRESENCE OF THE ENGINEER AUTHORIZED REPRESENTATIVE.
UNLESS OTHERWISE APPROVED, PILES SHALL BE DRIVEN BY VIBRATION OR BY THE GIKEN METHOD.
THE CONTRACTOR SHALL NOT ATTEMPT TO DRIVE PILES BEYOND THE POINT OF REFUSAL, AS INDICATED BY EXCESSIVE BOUNCING OF
THE HAMMER OR KICKING OF THE PILE.
6. SHEET PILES
THE PILING SHALL BE DRIVEN IN A MANNER THAT ENSURES PERFECT INTERLOCKING THROUGHOUT THE ENTIRE LENGTH OF EACH PILE.
THE PILES SHALL BE HELD IN PROPER ALIGNMENT DURING DRIVING BY ASSEMBLING FRAMES OR OTHER SUITABLE TEMPORARY GUIDE
STRUCTURES. TEMPORARY GUIDE STRUCTURES SHALL BE REMOVED WHEN THEY HAVE SERVED THEIR PURPOSE.
ANYTIME THE FORWARD EDGE OF THE SHEET PILE WALL IS FOUND TO BE OUT OF CORRECT ALIGNMENT, A. THE PILING ALREADY ASSEMBLED AND PARTLY DRIVEN SHALL BE DRIVEN TO THE REQUIRED DEPTH.
B. TAPER PILES SHALL BE DRIVEN TO BRING THE FORWARD EDGE INTO CORRECT ALIGNMENT BEFORE ADDITIONAL REGULAR
PILING IS ASSEMBLED AND DRIVEN. THE MAXIMUM PERMISSIBLE TAPER IN A SINGLE PILE SHALL BE 0.25 INCH PER FOOT OF
LENGTH.
7. CUTTING OFF PILES
THE CONTRACTOR SHALL CUT THE PILES AT THE SPECIFIED ELEVATIONS. THE LENGTH OF PILE CUT OFF SHALL BE SUFFICIENT TO
PERMIT THE REMOVAL OF ALL DAMAGED MATERIAL.
STEEL PILES SHALL BE CUT OFF IN CLEAN, STRAIGHT LINES. ANY IRREGULARITIES SHALL BE LEVELED OFF WITH DEPOSITS OF WELD
METAL OR BY GRINDING BEFORE PLACEMENT OF THE CAP.
8. DEFECTIVE PILES
ANY PILE DAMAGED IN DRIVING, DRIVEN OUT OF PROPER LOCATION, DRIVEN BELOW THE SPECIFIED CUTOFF ELEVATION, OR
INACCURATELY CUT OFF SHALL BE CORRECTED BY ONE OF THE FOLLOWING METHODS, AS APPROVED BY THE ENGINEER.
A. THE DEFECTIVE PILE SHALL BE PULLED AND REPLACED OR RE-DRIVEN.
B. A NEW PILE SHALL BE DRIVEN ADJACENT TO THE DEFECTIVE PILE.
C. THE DEFECTIVE PILE SHALL BE SPLICED OR BUILT UP OR A SUFFICIENT PART OF THE FOOTING SHALL BE EXTENDED TO
PROPERLY EMBED THE PILE.
ALL PILES PUSHED UP BY THE DRIVING OF ADJACENT PILES OR BY ANY OTHER CAUSE SHALL BE RE-DRIVEN TO FINAL GRADE.
ANY SHEET PILE RUPTURED IN THE INTERLOCK OR OTHERWISE DAMAGED DURING DRIVING SHALL BE PULLED AND REPLACED.
9. CORRECTING SURFACE HEAVE
ANY EXCESS MATERIAL RESULTING FROM DISPLACEMENT OF EARTH BY PILE DRIVING SHALL BE REMOVED. MATERIALS DISTURBED BY
PILE DRIVING SHALL BE CONDITIONED AND COMPACTED TO A MINIMUM DENSITY EQUAL TO ADJACENT UNDISTURBED MATERIAL.
INSTALLATION OF SHEET PILING:
DURING THE SHEET PILE INSTALLATION, THE STRUCTURES IN THE AREA SHALL BE MONITORED IN ACCORDANCE WITH SECTION 108 OF
FLORIDA DEPARTMENT OF TRANSPORTATION, STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION (2017). IF THE
CONTRACTOR USES THE GIKEN METHOD OF INSTALLATION, THE CONTRACTOR SHALL BE EXEMPT FOR THE PROVISIONS OF SECTION 108.
THE CONTRACTOR SHALL ANTICIPATE ISOLATED OBSTRUCTIONS DUE TO TREE ROOTS AND OTHER DEBRIS. OBSTRUCTIONS SHALL BE
PENETRATED OR REMOVED. COSTS RELATED TO ISOLATED OBSTRUCTIONS SHALL BE INCLUDED IN THE COST FOR PERMANENT STEEL
SHEET PILING.
JETTING SHALL NOT BE ALLOWED FOR SHEET PILE INSTALLATION.
STEEL SHEET PILES SHALL CONFORM TO THE REQUIREMENTS OF ASTM A328, A572, OR A690.
FABRICATION OF PILES FROM SHORTER LENGTHS OF PILE STOCK IS NOT PERMITTED.
MAINTENANCE OF TRAFFIC:
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION AND MAINTENANCE OF TRAFFIC BY THE PROPER USE OF BARRICADES, WARNING LIGHTS, FLARES AND NECESSARY TRAFFIC CONTROL AND SAFETY DEVICES. ALL FORMS OF TRAFFIC CONTROL SHALL BE IN
ACCORDANCE WITH THE MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS, TRAFFIC CONTROL FOR
HIGHWAY CONSTRUCTION AND MAINTENANCE OPERATIONS. THE CONTRACTOR SHALL PROVIDE SIGNAGE FOR 'ROAD CLOSED TO THRU
TRAFFIC' AND 'DETOUR'. ACCESS SHALL BE CONTINUOUSLY MAINTAINED FOR ALL PROPERTY OWNERS SURROUNDING THE WORK SITE.
LIGHTED WARNING DEVICES ARE TO BE OPERATIONAL PRIOR TO DUSK EACH NIGHT DURING CONSTRUCTION.
MAINTENANCE OF TRAFFIC SHALL COMPLY WITH FDOT SECTION 102.
NORTH WINTER PARK DRIVE MAY BE CLOSED DURING THE INSTALLATION OF THE SHEET PILING. THE ROAD MAY BE CLOSED TWICE DURING
CONSTRUCTION FOR TWO - FIVE (5) DAY DURATIONS. THESE CLOSURES SHALL BE PRE-ARRANGED AND APPROVED WITH THE CITY OF
CASSELBERRY; THE FIRE DEPARTMENT; AND, THE POLICE DEPARTMENT A MINIMUM OF SEVEN (7) CALENDAR DAYS IN ADVANCE OF THE
CLOSURE. ROADWAY SHALL BE RE-OPENED ON THE WEEKENDS. ROAD CLOSURE BARRICADES SHALL BE PROVIDED ON THE NORTHERN
STRETCH OF NORTH WINTER PARK DRIVE AT GEE CREEK LANE. ANOTHER BARRICADE SHALL BE PLACED JUST SOUTH OF BELLE AVENUE
AND NORTH WINTER PARK DRIVE.
ROAD CLOSURE, LOCAL TRAFFIC ONLY AND DETOUR SIGNS SHALL BE PLACED AT NORTH WINTER PARK DRIVE AND S.R. 434 (THE NORTH
END) AND NORTH WINTER PARK DRIVE AND SEMINOLA BOULEVARD (THE SOUTH END). THE DETOUR ROUTE SHALL BE ESTABLISHED AS
WEST TO U.S. 17-92 VIA SEMINOLA BOULEVARD; NORTH ALONG U.S. 17-92 TO S.R. 434.
AT ALL OTHER TIMES DURING CONSTRUCTION ACTIVITIES, ONE LANE (THE SOUTHBOUND LANE) MAY BE CLOSED DURING THE WORKING
HOURS OF 8 A.M. UNTIL 4 P.M., MONDAY THROUGH FRIDAY, WITH THE USE OF FLAG ATTENDANTS TO ALLOW TRAFFIC IN BOTH DIRECTIONS.
THE ROAD SHALL BE OPEN AT THE END OF THE WORK DAY.
MAINTENANCE OF PEDESTRIAN TRAFFIC:
CONTRACTOR SHALL CLOSE THE SIDEWALK ON THE WEST SIDE OF WINTER PARK DRIVE. CONTRACTOR SHALL PROVIDE CLOSURE SIGNAGE
AND SHALL PROVIDE AN ACCESSIBLE TEMPORARY CROSSING NORTH OF THE PROJECT AREA TO THE EAST SIDE OF NORTH WINTER PARK
DRIVE AND ON TO THE INTERSECTION OF GEE CREEK LANE AND NORTH WINTER PARK DRIVE. TEMPORARY CROSSINGS MUST BE
PROMINENTLY SIGNED, INCLUDING ADVANCE WARNING SIGNAGE FOR MOTORISTS AS NEEDED. THE GEE CREEK LANE AND NORTH WINTER
PARK DRIVE INTERSECTION SHALL BE MAINTAINED AT ALL TIMES.
MAINTENANCE OF GEE CREEK FLOW:
FLOW SHALL BE MAINTAINED AT ALL TIMES IN GEE CREEK. NO CONSTRUCTION ACTIVITIES EXCEPT TURBIDITY CONTROL DEVICES IS
ALLOWED IN THE STREAM BED OR ADJACENT AREAS.
Scale:
Job No.
Date:
TMZ
DEM
DGH
TMZ
Checked by:
Approved by:
Designed by:
Drawn by:
Sheet No.
D r a w i n g n a m e
J C
C i v i l D
W G
D e s i g n C
G e n e r a l
N o t e s d r p m d g h o l l a n d
ByNo. Date
2017C
C1990
4/04/2017
TERRY M. ZAUDTKE, P.E.
REG-# 32928
NONE C-2
ByNo. Date Revision Revision
1117 E. Robinson St. Orlando, FL 32801
Ph: 407.425.0452
CPH, Inc.
Arch. Lic. No. AA2600926
Landscp. Lic. No. LC0000298
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Plans Prepared By:
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Structural
Surveyors
Offices In:
· Florida
· Puerto Rico
· Connecticut
· Maryland
· Texas
A Full Service A & E Firm
GENERAL NOTES
Traffic/Transportation
CITY OF CASSELBERRY
GEE CREEK EROSION CONTROL PROJECT
PHASE 1 - SHEET PILING
Seminole County, Florida
SITE BENCHMARK #1SITE BENCHMARK #2
SITE BENCHMARK #3
LOT 1
LOT 2
LOT 3
LOT 4
11+00
12+00
12+82.58
TB-3
TB-4
TB-1
TB-2
Scale:
Job No.
Date:
TMZ
DEM
DGH
TMZ
Checked by:
Approved by:
Designed by:
Drawn by:
Sheet No.
D r a w i n g n a m e
J C
C i v i l D
W G
D e s i g n C i t l a n d
M a r a m d g h o l l a n d
ByNo. Date
2017C
C1990
3/27/2017
TERRY M. ZAUDTKE, P.E.
REG-# 32928
1" = 10' C-3
ByNo. Date Revision Revision
1117 E. Robinson St. Orlando, FL 32801
Ph: 407.425.0452
CPH, Inc.
Arch. Lic. No. AA2600926
Landscp. Lic. No. LC0000298
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Plans Prepared By:
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Structural
Surveyors
Offices In:
· Florida
· Puerto Rico
· Connecticut
· Maryland
· Texas
A Full Service A & E Firm
SITE PLAN
Traffic/Transportation
CITY OF CASSELBERRY
GEE CREEK EROSION CONTROL PROJECT
PHASE 1 - SHEET PILING
Seminole County, Florida
N
Graphic Scale in Feet
10 10 20
WINTER PARK DRIVE
G E
E C
R E
E K
L A
N E
GEE CREEK COURT
GEE CREEK
N: 1582287.36
E: 555189.90
N: 1582020.90
E: 555189.90
PROVIDE TWO SHEETS OF
PILING AT THE END BURIED
INTO GRADE PERPENDICULAR
TO THE MAIN SHEETING.
3' OFFSET
APPROXIMATELY 170 L.F.
OF SHEET PILING
SHEET PILE SECTION PZ35 - 37 FEET LONG
TOP OF SHEET PILE - 50' ±
BOTTOM OF SHEET PILE - 13' ±
APPROXIMATELY 15 L.F.
OF SHEET PILING
END OF SHEET PILING
BEGINNING OF SHEET PILING
INSTALL FLOATING TURBIDITY
BARRIER PER FDOT SECTION 104
(2017). SEE SHEET C-5 FOR DETAILS.
INSTALL EROSION CONTROL
MEASURES PER FDOT SECTION 104
(2017). SEE SHEET C-5 FOR DETAILS.
LEGEND
EXISTING CONTOURS
EXISTING SPOT ELEVATIONS
APPROXIMATE SOIL BORING LOCATION
PROPOSED SHEET PILING
TB-1
PROPOSED FLOATING TURBIDITY BARRIER
PROPOSED TYPE III SILT FENCE
NOTES:
1. ALL SOIL BORING LOCATIONS ARE APPROXIMATE AND HAVE NOT BEEN
SURVEYED. FOR MORE INFORMATION SEE SOILS REPORT.
2. CROSS SECTIONS FOR EVERY 50' HAVE BEEN PROVIDED ON SHEET C-4.
3. SHEET PILE SECTION IS PZ35.
4. TOP OF SHEET PILE CONCRETE CAP IS ELEV. = 51.50
5. REGRADE AREA FROM THE EDGE OF THE ROADWAY TO THE TOP OF THE
CONCRETE CAP. PROVIDE GRADUAL SLOPE AS REQUIRED. SEE TYPICAL
REGRADE DETAIL, SHEET C-5.
TURNING POINT
CONTRACTOR TO PROTECT HYDRANT DURING
CONSTRUCTION. FIELD LOCATE ALL WATER
LINES IN AREA PRIOR TO THE START OF
CONSTRUCTION. ISOLATE HYDRANT WITH
VALVE SHUT-OFF. BAG HYDRANT DURING
CONSTRUCTION TO PREVENT USE. NOTIFY THE
FIRE DEPARTMENT TWO WEEKS AHEAD OF
WORK AND IDENTIFY DURATION OF OUTAGE.
PROVIDE CONCRETE CAP.
SEE SHEET C-5 FOR DETAIL.
PROVIDE TWO SHEETS OF
PILING AT THE END BURIED
INTO GRADE PERPENDICULAR
TO THE MAIN SHEETING.
4" CONCRETE SLAB BETWEEN
EXISTING WALL AND SHEET PILING
4" CONCRETE FILL
SOD
10 Scale
10 Scale
10 Scale
10 Scale
Scale:
Job No.
Date:
TMZ
DEM
DGH
TMZ
Checked by:
Approved by:
Designed by:
Drawn by:
Sheet No.
D r a w i n g n a m e
J C
C i v i l D
W G
D e s i g n C r o s s
S e c t i o n s d r a m d g h o l l a n d
ByNo. Date
2017C
C1990
3/27/2017
TERRY M. ZAUDTKE, P.E.
REG-# 32928
NONE C-4
ByNo. Date Revision Revision
1117 E. Robinson St. Orlando, FL 32801
Ph: 407.425.0452
CPH, Inc.
Arch. Lic. No. AA2600926
Landscp. Lic. No. LC0000298
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Plans Prepared By:
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Structural
Surveyors
Offices In:
· Florida
· Puerto Rico
· Connecticut
· Maryland
· Texas
A Full Service A & E Firm
CROSS SECTIONS
Traffic/Transportation
CITY OF CASSELBERRY
GEE CREEK EROSION CONTROL PROJECT
PHASE 1 - SHEET PILING
Seminole County, Florida
EXISTING GRADE
SHEET PILE CONCRETE CAP
PROPOSED SHEET PILING
ELEV. = 13.00 ELEV. = 13.00 ELEV. = 13.00 ELEV. = 13.00
ELEV. = 50.75 ELEV. = 50.75 ELEV. = 50.75 ELEV. = 50.75
SHEET PILE CONCRETE CAP
SHEET PILE
CONCRETE CAP
SHEET PILE
CONCRETE CAP
PROPOSED
SHEET PILING
PROPOSED
SHEET PILING
PROPOSED
SHEET PILING
EXISTING GRADE
EXISTING GRADE
EXISTING GRADE
EXISTING
CONCRETE WALL
EXISTING
CONCRETE WALL
EXISTING
CONCRETE WALL
STATION 12+20 D
SCALE: 1" = 20' H
C-3 C-4
1" = 2' V
STATION 11+70 C
SCALE: 1" = 20' H
C-3 C-4
1" = 2' V
STATION 11+20 B
SCALE: 1" = 20' H
C-3 C-4
1" = 2' V
STATION 10+70 A
SCALE: 1" = 20' H
C-3 C-4
1" = 2' V
4" CONCRETE SLAB
4" CONCRETE SLAB
4" CONCRETE SLAB
NOT TO SCALE
TYPE III SILT FENCE
SEC. 985 FDOT SPEC.)
CONFORMANCE WITH
FILTER FABRIC (IN
POSITIONS
OPTIONAL POST
(CANTED 20° TOWARD FLOW)
V E
R T
I C
A L
SECTION
WOOD; STEEL 1.33
POST (OPTIONS: 2"x4"
OR 2-1/2" MIN. DIA.
LBS/FT. MIN.)
SILT FLOW
FABRIC
FILTER
ELEVATION
T
O
O
R
M
O R
E
M
I N
6' MAX
PRINCIPAL POST POSITION
unit price for Staked Turbidity Barrier, LF.
contract unit price for Floating Turbidity Barrier, LF.
APPROVED BY THE ENGINEER.
THE USER. SUBSTITUTIONS FOR TYPES ~ AND ~~ SHALL BE AS
RIGHTS OF THE DESIGNER SHALL BE THE SOLE RESPONSIBILITY OF
TO PROPRIETARY DESIGNS. ANY INFRINGEMENT ON THE PROPRIETARY
NOTICE: COMPONENTS OF TYPES ~ AND ~~ MAY BE SIMILAR OR IDENTICAL
D =5' Std. (Single Panel For Depths 5' or Less).
Test) With Lacing Grommets
PVC Fabric (300 psi
18 Oz. Nylon Reinforced
TYPE ~
TYPE ~~
Per Ft. Buoyancy)
Flotation (6" Dia. Equiv.) (12 Lbs.
Closed Cell Solid Plastic Foam
Flotation (8" Dia. Equiv.) (17 lbs.
Per Ft. Buoyancy)
Closed Cell Solid Plastic Foam
(9800 Lbs. Breaking Strength) With
Vinyl Sheathed EAW Steel Cable
1.33 Lbs/Ft. Min.)
PVC Fabric (300 psi Test)
18 Oz. Nylon Reinforced
Post (Options: 2" x 4" Or
STAKED TURBIDITY BARRIER
Min. Dia. Wood; Steel
O r
M o r e
M i n
6' Max.
2. Staked turbidity barriers are to be paid for under the contract
T i d l e e k
S t r e m
Limits Of Const.
Shore Line
Barriers
Turbidity
Limits Of Const.
Shore Line be under the pay item(s) established in the quality requirements. The barrier type(s) will
4. Navigation may require segmenting barrier during construction operations.
3. Deployment of barrier around pile locations may vary to accommodate construction operations.
2. Number and spacing of anchors dependent on current velocities.
1. Turbidity barriers are to be used in all permanent bodies of water regardless of water depth.
5. For additional information see Section 104 of the Standard Specifications.
Strength)
(600 lb. Breaking
Polypro Rope
D =5' Std. (Additional Panel For Depths 5').
PVC Fabric (300 psi Test)
18 Oz. Nylon Reinforced
Galvanized Connectors (Tool Free Disconnect)
(Metal Collar Reinforced)
Slotted PVC Connector Pipe
GENERAL NOTES
1. Floating turbidity barriers are to be paid for under the
For In The Plans Or As Determined By The Engineer.
10 Feet Unless Special Depth Curtains Specifically Called
Two(2) Panels To Be Used For Depths Greater Than
Curtain To Reach Bottom Up To Depths Of 10 Feet.
D
D
D
FLOATING TURBIDITY BARRIERS
Turbidity barriers for flowing streams and tidal
Mooring Buoy w/Anchor
To Current Action
Barrier Movement Due
Anchor
Dredge Or Fill Area
Pile Locations
LEGEND
TURBIDITY BARRIER APPLICATIONS
NOTES:
Stress Plate
Galvanized Chain
Galvanized Chain
T y p i c a l
T y p i c a l
Shore Line
T y p i c a l
Proposed Toe Of Slope
Causeway
Existing
T y p i c a l
Structure Alignment
Current
Engineer.
position unless otherwise directed by the turbidity barriers to be installed in vertical
Staked Turbidity Barrier. Posts in staked plans for Floating Turbidity Barrier and/or specified in the plans, however payment will be at the Contractors option unless otherwise conditions and meet erosion control and water or any combinations of types that will suit site creeks may be either floating, or staked types
Note:
TUBIDITY BARRIER DETAILS (FDOT INDEX 103)
NOT TO SCALE
#4 BAR (TYP.)
SHEET PILE
SECTION A-A
NOT TO SCALE
SHEET PILE CONCRETE CAP
2'-1"
4C06 BAR @ 2'-0" O.C.
#4 BAR (TYP.)
±15"
SHEET PILE
3" CL
1'-7"
6" 6"
1'-7"
1'-1"
SECTION B-B
4CO5
4CO6
COPING REINFORCING PARTIAL PLAN
2 - #4 BARS (CONTINUOUS
TOP AND BOTTOM)
#4 BAR
PZ35 SHEET PILE
4C05 BARS @ 22.6" O.C.
(TYPICAL AT EACH SHEET PILE JOINT, ALTERNATING ORIENTATIONS)
4C06 BARS @ 22.6" O.C.
(TYPICAL AT EACH SHEET PILE CENTERLINE)
3" CL
CENTER OF SHEET
PILE WALL
2 - #4 BARS (CONTINUOUS
TOP AND BOTTOM)
BEGIN SHEET PILE WALL
STA. 10+00 OR
END SHEET PILE WALL
STA. 15+00
B A
B A
6" MIN. TO 9" MAX.
SHEET PILE EMBEDMENT
2'-1"
3" CL
±15"
6" MIN. TO 9" MAX.
SHEET PILE EMBEDMENT
4C05 BAR @ 2'-0" O.C.
WITH ALTERNATION
ORIENTATIONS
TOP ELEV. = ±51.50
TOP ELEV. = ±51.50
NOTES:
1. CAP DETAILS ARE BASED SPECIFICALLY ON THE USE OF A PZ35 STEEL SHEET PILING SECTION. IF A DIFFERENT SECTION IS USED, CONTRACTOR MUST
OBTAIN APPROVAL AND THE CAP SHALL BE MODIFIED AT CONTRACTORS EXPENSE.
2. THE ENTIRE TOP AND SIDES OF CONCRETE CAP SHALL RECEIVE A SURFACE FINISH AND CLASS V COATING CONFORMING TO SECTION 400-15.2.6 OF
THE FDOT SPECIFICATIONS. COLOR OF CLASS V COATING SHALL BE SUBMITTED FOR OWNER APPROVAL PRIOR TO PROCUREMENT.
3. CONCRETE SHALL BE FDOT CLASS II (MINIMUM 28-DAY COMPRESSIVE STRENGTH = 3,400 psi). CONCRETE SHALL CONFORM TO SECTION 346 OF THE
FDOT SPECIFICATIONS.
4. REINFORCING STEEL SHALL BE ASTM A615, GRADE 60.
Scale:
Job No.
Date:
Checked by:
Approved by:
Designed by:
Drawn by:
Sheet No.
D r a w i n g n a m e
J C
C i v i l D
W G
D e s i g n C
D t a i l s d r a m d g h o l l a n d
ByNo. Date
2017C
3/27/2017
AS SHOWN
ByNo. Date Revision Revision
1117 E. Robinson St. Orlando, FL 32801
Ph: 407.425.0452
CPH, Inc.
Arch. Lic. No. AA2600926
Landscp. Lic. No. LC0000298
Licenses:
Eng. C.O.A. No. 3215
Survey L.B. No. 7143
Plans Prepared By:
www.cphcorp.com
Architects
Engineers
Environmental
Landscape Architects
M / E / P
Planners
Structural
Surveyors
Offices In:
· Florida
· Puerto Rico
· Connecticut
· Maryland
· Texas
A Full Service A & E Firm
Traffic/Transportation
TMZ
DEM
DGH
TMZ
C1990
TERRY M. ZAUDTKE, P.E.
REG-# 32928
C-5DETAILS
FDOT INDEX #103
CITY OF CASSELBERRY
GEE CREEK EROSION CONTROL PROJECT
PHASE 1 - SHEET PILING
Seminole County, Florida
EXISTING
GRADE
STEEL SHEET
PILING SECTION
CONCRETE SHEET
PILING CAP
ELEV. = 50.75
PROVIDE MISCELLANEOUS
FILL AND COMPACT TO 98%
MODIFIED T-180, IN 12" LIFTS
TYPICAL REGRADE DETAIL
N.T.S.
EXISTING
ROADWAY
REGRADE SLOPE TO CAP. PROVIDE
4" CONCRETE SLAB ON TOP.
SLOPE IS APPROXIMATELY 10:1
EXISTING
CONCRETE WALL
ELEV. = 13.00
| Sheets and Views |
| C-1 Cover |
| C-2 General Notes |
| C-3 Site Plan |
| C-4 Cross Sections |
| C-5 Details |
| 2017-04-25T13:30:20-0400 | |
| Terry M Zaudtke |
| 2017-04-25T13:31:06-0400 | |
| Terry M Zaudtke |
| 2017-04-25T13:31:38-0400 | |
| Terry M Zaudtke |
| 2017-04-25T13:32:08-0400 | |
| Terry M Zaudtke |
| 2017-04-25T13:32:39-0400 | |
| Terry M Zaudtke |
File details come from the government source that posted it. Updated .