About this file
This document is a Specifications Attachment for a Louisiana Department of Corrections (DOC) fire hydrant replacement and repair project at the Allen Correctional Center in Kinder, Louisiana. The scope of work requires a contractor to supply labor, materials, and equipment to replace and repair fire hydrants, specifically involving two primary tasks: replacing a fire hydrant behind the maintenance shop and repairing a leaking fire hydrant in front of travel trailers. The preferred fire hydrant brand is Mueller Super Centurion Fire Hydrant Series with 6-inch nominal pipe size and pressure ratings of 250 PSI or 350 PSI. A site contact, Taylor Maricle, is provided for potential bidders, with contact information for site visit coordination.
The specifications outline detailed requirements for the contractor, including shutting off water, excavation, hydrant removal and replacement, backfilling, leak verification, and work area cleaning. The contractor is responsible for material delivery and pickup, debris disposal, and must schedule water outages with facility maintenance while providing estimated downtime. No specific pricing, funding sources, or contract term details are provided in this document. The project appears to be a targeted maintenance and infrastructure improvement initiative for the DOC's correctional facility, focusing on critical water infrastructure reliability and safety.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3000025345-1.pdf | ||
| Attachment A - Special Terms and Conditions Pages 1-12.docx | DOCX document | |
| Attachment B - Job Site Verification Form - Page 1.docx | DOCX document | |
| 3000025345.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment C – Specifications RFx 3000025345
**If bidding other than specified, please provide manufacturer’s specs for “or equal” items. ** Scope of Work The Contractor shall supply all labor, rentals, permits and materials to replace and repair fire hydrants for the Department of Corrections (DOC).
Location:
DOC Allen Correctional Center 3751 Lauderdale Woodyard Rd.
Kinder, La. 70648
Site Visit Contact:
Taylor Maricle 337-375-6611 Taylor.Maricle@la.gov
The Contractor shall be responsible for the following:
Fire hydrant replacement:
Brand/Model: Mueller Super Centurion Fire Hydrant Series or Equal Nominal Pipe Size: 6” Pressure Rating: A423 (250 PSI), A423HP (350 PSI) A-2361-23 Mechanical Joint Ends
Specify Brand/Model Bidding: _____________
· Replace fire hydrant behind maintenance shop
· Shut water off to fire hydrant
· Dig down to fire main
· Remove piping and fire hydrant from valve in the ground
· Turn water back on
· Verify no leaks are present
· Backfill and pack dirt with proper kickers in place
· Verify proper operation
· Cleaning of general work area
Fire hydrant repair:
· Investigate and repair leaking fire hydrant in front of travel trailers
· Shut water off to fire hydrant
· Dig down and investigate what is causing fire hydrant to leak from the ground
· Attempt to close drain check and fire hydrant will need to be replaced if drain check is unable to be closed.
· Install repair kit if needed.
· Verify no leaks are present and proper operation of fire hydrant
· Cleaning of general work area
General Terms:
· The Contractor shall schedule any water outages with facility maintenance and provide an estimation for the period of time the water will be off.
· The Contractor shall be responsible for delivery and pickup of materials/supplies needed to complete project.
· Disposal of all materials, and debris shall be the responsibility of the contractor.