Attachment C - Specifications - Page 1.docx
DOCX document 20 KB Posted
- Attached to
- Roof Repairs - DMA - Addendum No. 1 - Specification Revisions and Extending Bid Opening Dat
- Solicitation number
- 3000025500
- Issued by
- Red River Parish, Louisiana
About this file
This is a Scope of Work specification document for the Department of Military Affairs (DMA) in Louisiana. The project involves roof leak repair services at Building 425 of the Naval Air Station located at 400 Russell Avenue in Belle Chasse, Louisiana. The contractor shall supply all labor, materials, and equipment necessary to complete the specified repairs, including installing one new metal vent cap, removing and replacing existing vent boots with new boots and sealant, cutting out and replacing sealant around all vent curb penetrations, removing and replacing existing screws and washers on ridge cap flashing with new versions, and cutting out and replacing sealant on ridge flashing overlaps with new screws. The DMA contact for the project is Gary Lipkos, reachable at (985) 634-5703 or Gary.lipkos.1@us.af.mil.
The contractor shall be responsible for securing the building and sensitive items at the end of each workday, taking all necessary precautions to prevent damage during repairs, and managing disposal and storage of all removed and installed materials. The contractor must also exercise caution regarding equipment movement and parking on grass or unimproved areas surrounding the site. Upon successful completion of inspection, work will be accepted. The contractor is required to provide a one-year warranty on workmanship and the completed project, with the warranty period beginning from the date the certificate of completion is filed. No specific pricing information, set-asides, response deadlines, or award dates are provided in this specification document.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Addendum No. 1.docx | DOCX document | |
| Revised Attachment C - Specifications - Pages 1-2.docx | DOCX document | |
| 3000025500-1.pdf | ||
| Attachment A - Special Terms and Conditions Pages 1-11.docx | DOCX document | |
| Attachment B - Job Site Verification Form - Page 1.docx | DOCX document | |
| 3000025500.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment C – Specifications RFx 3000025500
Scope of Work:
The Contractor shall provide all labor, materials, and equipment necessary to repair roof leaks on Building 425 of the Louisiana Naval Air Station for the Department of Military Affairs (DMA).
Location Naval Air Station 400 Russell Ave.
Belle Chasse, LA 70037
DMA Contact:
Gary Lipkos
(985) 634-5703 Gary.lipkos.1@us.af.mil
Specification:
The Contractor shall be responsible for the following:
· Supply and install one new metal vent cap to replace the missing cap.
· Remove and replace existing vent boots with new boots and sealant.
· Cut out and replace sealant around all vent curb penetrations.
· Remove and replace existing screws and washers on ridge cap flashing with new screws and washers.
· Cut out and replace sealant on ridge flashing overlaps, and install new screws.
Terms and Conditions:
· Upon successful completion of the inspection, the work will be accepted.
· The Contractor shall secure the building, and any sensitive items at the end of each workday in accordance with the jobsite visit contact.
· The Contractor shall take all precautions necessary to prevent damages when making repairs. This includes movement and parking of equipment on grass or unimproved areas surrounding site.
· The Contractor shall be responsible for disposal and storage of all materials being removed or installed throughout the project.
· The Contractor shall warranty their workmanship and the completed project for a 1 year period. The 1-year period starts with the date of the filing of the certificate of completion.