ATTACHMENT C - PLANS AND DRAWINGS Thompsons Mills Electrical and Fire Risk Reduction Project.pdf

PDF 4 MB Posted

Attached to
#12488 Thompson's Mills Electrical and Fire Risk Reduction Project
Solicitation number
S-63400-00012388
Issued by
Lake County, Siletz City, Oregon

About this file

This is a set of electrical plans and drawings for Thompson's Mills Electrical and Fire Risk Reduction Project administered by the Oregon Parks & Recreation Department. The plans detail electrical upgrades at the Thompson's Mills State Heritage Site in Linn County, Oregon, including demolition of existing electrical equipment, installation of new panelboards, relocation of motor controls, and lighting improvements. The project involves upgrading the mill building's electrical systems, including new lighting controls that will operate at 100% brightness from dusk until 10pm and dim to 50% from 10pm until dawn. The plans show detailed electrical layouts for the basement, first, second, third and fourth floors of the facility.

The drawings include comprehensive electrical symbols lists, general electrical notes, demolition plans, new installation details, and one-line power distribution diagrams. Key components include new lighting control systems, panel schedules showing circuit assignments and load calculations, and enlarged plans of electrical rooms showing equipment placement and modifications. The plans indicate multiple electrical rooms (Green, Black, Blue and Main) that require equipment removal and new installations. Technical specifications show power requirements, circuit details and wiring schedules for the various systems being upgraded or replaced.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

Ap pr ov er

Ch ec ke r

Au th or

PE

RM

IT

/B

ID

S

ET

/0

8/ brian.mcbeth Snapshot brian.mcbeth Text Box

COVER

brian.mcbeth Text Box

MILL BUILDING ELECTRICAL UPGRADES

brian.mcbeth Text Box

BRIAN MCBETH, HISTORIC ARCHITECTURE PROJECT MANAGER

EMAIL: BRIAN.MCBETH@OPRD.OREGON.GOV

PHONE: 971.374.3073

brian.mcbeth Text Box

SCOTT YOUNGBLOOD, PARK MANAGER

EMAIL: SCOTT.YOUNGBLOOD@OPRD.OREGON.GOV

PHONE: 541.517.8580

brian.mcbeth Text Box

33170 - THOMPSONS MILLS ELECTRICAL

brian.mcbeth Rectangle

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

/0

8/

SY

M

BO

L

LI

ST

A

ND

G

EN

ER

AL

N

OT

ES

E

LE

CT

RI

CA

L

E0.1

PE

RM

IT

/B

ID

S

ET

E0.1 SYMBOL LIST AND GENERAL NOTES - ELECTRICAL

E0.2 LIGHTING CONTROL MATRIX

ED2.0 DEMOLITION FLOOR PLAN - BASEMENT LEVEL - ELECTRICAL

ED2.1 DEMOLITION FLOOR PLAN - FIRST FLOOR - ELECTRICAL

E2.0 FLOOR PLAN - BASEMENT LEVEL - ELECTRICAL

E2.1 FLOOR PLAN - FIRST FLOOR - ELECTRICAL

E2.2 FLOOR PLAN - SECOND FLOOR - ELECTRICAL

E2.3 FLOOR PLAN - THIRD FLOOR - ELECTRICAL

E2.4 FLOOR PLAN - FOURTH FLOOR - ELECTRICAL

E4.1 ENLARGED PLANS - ELECTRICAL

E4.2 ENLARGED PLANS - ELECTRICAL

E4.3 ENLARGED PLANS - ELECTRICAL

E4.4 ENLARGED PLANS - ELECTRICAL

E4.5 ENLARGED PLANS - ELECTRICAL

E5.0 ONE-LINE DIAGRAM - ELECTRICAL

E6.0 SCHEDULES - ELECTRICAL

E6.1 SCHEDULES - ELECTRICAL

GENERAL ELECTRICAL NOTES

SHEET INDEX

Abbreviations

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

AWG AMERICAN WIRE GAUGE

A AMPERES, AMBER

AHJ AUTHORITY HAVING JURISDICTION

AIC AVAILABLE INTERRUPTING CAPACITY

BAS BUILDING AUTOMATION SYSTEM

CA CABLE

CAT CATEGORY

CLG CEILING

C CONDUIT, CLOSE, CONTROL

COORD COORDINATE

CU COPPER

dB DECIBEL

(X) DEMOLISH

DTL DETAIL

DIA DIAMETER

DIM DIMENSION

DIV DIVISION

DN DOWN

DWG DRAWING

EA EACH

EMT ELECTRICAL METALLIC TUBING

EL ELEVATION

E EMERGENCY

EF EXHAUST FAN

(E) EXISTING TO REMAIN

FF FINISH FLOOR

FA FIRE ALARM

FACP FIRE ALARM CONTROL PANEL

FMC FLEXIBLE METAL CONDUIT

FT FOOT, FEET

FBO FURNISHED BY OTHERS

G, GND GROUND

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GFI GROUND FAULT INTERRUPTER

GFP GROUND FAULT PROTECTION

HH HANDHOLE

HT HEIGHT

ID IDENTIFICATION

IN INCH, INCHES

IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS

IMC INTERMEDIATE METAL CONDUIT

IG ISOLATED GROUND

KV KILOVOLT

KVA KILOVOLT AMPERES

KW KILOWATT

LED LIGHT EMITTING DIODE

LFMC LIQUIDTIGHT FLEXIBLE METAL CONDUIT

LV LOW VOLTAGE

MOCP MAXIMUM OVERCURRENT PROTECTION

mA MILLIAMPERES

MIN MINIMUM

MCA MINIMUM CIRCUIT AMPS

MISC MISCELLANEOUS

MCC MOTOR CONTROL CENTER

MT, MTD MOUNT, MOUNTED

NEC NATIONAL ELECTRIC CODE

NESC NATIONAL ELECTRIC SAFETY CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

N NEUTRAL

(N) NEW

N/A NOT APPLICABLE

N.I.C. NOT IN CONTRACT

NTS NOT TO SCALE

OC ON CENTER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

PNL PANEL

PH PHASE

PVC POLY-VINYL-CHLORIDE

PWR POWER

QTY QUANTITY

REF REFERENCE

(R) RELOCATE

RFI REQUEST FOR INFORMATION

REQD REQUIRED

RMC RIGID METAL CONDUIT

RM ROOM

SHT SHEET

SIM SIMILAR

STD STANDARD

SPD SURGE PROTECTION DEVICE

SWBD SWITCHBOARD

TBD TO BE DETERMINED

XFMR TRANSFORMER

TVSS TRANSIENT VOLTAGE SURGE SUPPRESSOR

TYP TYPICAL

UG UNDERGROUND

UL UNDERWRITERS LABORATORIES

UPS UNINTERRUPTIBLE POWER SUPPLY

UON UNLESS OTHERWISE NOTED

VFD VARIABLE FREQUENCY DRIVE

V VOLTS, VOLTAGE

WP WEATHERPROOF

WG WIRE GUARD

W/ WITH

W/O WITHOUT

Connections / Equipment

COMBINATION ADJUSTABLE FREQUENCY DRIVE WITH SAFETY

DISCONNECT SWITCH. FURNISHED BY DIVISION 23 AND INSTALLED

BY DIVISION 26.

COMBINATION MOTOR STARTER/FUSED DISCONNECT SWITCH

HEAVY DUTY FUSED DISCONNECT SWITCH

MOTOR CONNECTION

NON-FUSED DISCONNECT SWITCH

TRANSFORMER

FIRE SMOKE DAMPER

SMOKE DAMPER

CEILING MOUNTED JUNCTION BOX

FLOOR MOUNTED JUNCTION BOX

WALL-MOUNTED JUNCTION BOX

Fire Alarm

FIRE ALARM CONTROL PANEL

General

DETAIL NUMBER AND SHEET LOCATION

EQUIPMENT IDENTIFICATION

KEYED NOTE

DEMOLISH

EXISTING WORK

NEW WORK

Lighting

COMBINATION EXIT SIGN CEILING MOUNTED AND DUAL HEAD

EMERGENCY EGRESS LIGHTING WITH BATTERY PACK. ARROW(S)

INDICATES DIRECTION IF SHOWN

COMBINATION EXIT SIGN WALL MOUNTED AND DUAL HEAD

EMERGENCY EGRESS LIGHTING WITH BATTERY PACK. ARROW(S)

INDICATES DIRECTION IF SHOWN

EXIT SIGN CEILING MOUNTED, ARROW(S) INDICATES DIRECTION IF

SHOWN

EXIT SIGN WALL MOUNTED, ARROW(S) INDICATES DIRECTION IF

SHOWN

RECESSED 1' X 4' LUMINAIRE

RECESSED 1' X 4' LUMINAIRE CONNECTED TO EMERGENCY/LIFE

SAFETY CIRCUIT OR WITH INTEGRAL EMERGENCY BATTERY

CONNECTED TO UNSWITCHED CIRCUIT

RECESSED 2' X 2' LUMINAIRE

RECESSED 2' X 2' LUMINAIRE CONNECTED TO EMERGENCY/LIFE

SAFETY CIRCUIT OR WITH INTEGRAL EMERGENCY BATTERY

CONNECTED TO UNSWITCHED CIRCUIT

RECESSED 2' X 4' LUMINAIRE

RECESSED 2' X 4' LUMINAIRE CONNECTED TO EMERGENCY/LIFE

SAFETY CIRCUIT OR WITH INTEGRAL EMERGENCY BATTERY

CONNECTED TO UNSWITCHED CIRCUIT

RECESSED LUMINAIRE

RECESSED LUMINAIRE CONNECTED TO EMERGENCY/LIFE SAFETY

CIRCUIT

SURFACE MOUNTED 2' X 2' LUMINAIRE CONNECTED TO

EMERGENCY/LIFE SAFETY CIRCUIT OR WITH INTEGRAL

EMERGENCY BATTERY CONNECTED TO UNSWITCHED CIRCUIT

SURFACE MOUNTED 2' X 4' LUMINAIRE

SURFACE MOUNTED 2' X 4' LUMINAIRE CONNECTED TO

EMERGENCY/LIFE SAFETY CIRCUIT OR WITH INTEGRAL

EMERGENCY BATTERY CONNECTED TO UNSWITCHED CIRCUIT

ELECTRICAL SYMBOL LIST

NOTE: This is a standard symbol list and not all items listed may be used.

A. DIVISION 26 CONTRACTORS ARE REQUIRED TO VERIFY EXISTING CONDITIONS

PRIOR TO BID WITH ENGINEER AND OWNER.

SURFACE OR PENDANT MOUNTED 1' X 4' LUMINAIRE

SURFACE OR PENDANT MOUNTED 1' X 4' LUMINAIRE CONNECTED

TO EMERGENCY/LIFE SAFETY CIRCUIT OR WITH INTEGRAL

EMERGENCY BATTERY CONNECTED TO UNSWITCHED CIRCUIT

SURFACE OR PENDANT MOUNTED LUMINAIRE CONNECTED TO

EMERGENCY/LIFE SAFETY CIRCUIT OR WITH INTEGRAL

EMERGENCY BATTERY CONNECTED TO UNSWITCHED CIRCUIT

SURFACE OR PENDANT MOUNTED STRIPLIGHT

WALL MOUNTED 6" WIDE LUMINAIRE

WALL MOUNTED 6" WIDE LUMINAIRE CONNECTED TO

EMERGENCY/LIFE SAFETY CIRCUIT OR WITH INTEGRAL

EMERGENCY BATTERY CONNECTED TO UNSWITCHED CIRCUIT

WALL MOUNTED 12" WIDE LUMINAIRE

WALL MOUNTED 12" WIDE LUMINAIRE CONNECTED TO

EMERGENCY/LIFE SAFETY CIRCUIT OR WITH INTEGRAL

EMERGENCY BATTERY CONNECTED TO UNSWITCHED CIRCUIT

WALL MOUNTED LUMINAIRE

WALL MOUNTED LUMINAIRE CONNECTED TO EMERGENCY/LIFE

SAFETY CIRCUIT OR WITH INTEGRAL EMERGENCY BATTERY

CONNECTED TO UNSWITCHED CIRCUIT

Miscellaneous

BRANCH CIRCUIT WIRING. ARROW INDICATES HOME RUN TO

PANEL WITH CIRCUITS AS NOTED. WIRE SIZE IS #12 AWG MINIMUM

UNLESS NOTED OTHERWISE. SHORT TICK MARKS INDICATE PHASE

CONDUCTORS. LONG TICK MARKS INDICATE NEUTRAL

CONDUCTORS. A SINGLE CURVED TICK MARK INDICATES

INSULATED GREEN GROUND CONDUCTOR. SECOND CURVED TICK

MARK INDICATES "ISOLATED GROUND" (GREEN INSULATION WITH

YELLOW STRIPE) CONDUCTOR.

BRANCH PANEL

CIRCUIT BREAKER

DRY TYPE TRANSFORMER

FLUSH WALL MOUNTED BRANCH PANEL

GROUND BAR

MAIN DISTRIBUTION PANEL / SUB DISTRIBUTION PANEL

Raceways

CONDUIT CONCEALED IN WALL OR CEILING SPACE

CONDUIT ROUTED BELOW FLOOR / GRADE

CONDUIT ELLED DOWN

CONDUIT ELLED UP

CONDUIT/WIRING CONTINUATION

CONDUIT/WIRING STUBBED OUT WITH END CAP OR INSULATED

PLASTIC BUSHING

FLEXIBLE CONDUIT

Switches and Receptacles

DUPLEX RECEPTACLE (MULTIPLE LETTERS INDICATE MULTIPLE

OPTIONS)

A = ABOVE COUNTER

B = CLOCK HANGER

C = FLUSH CEILING MOUNTED

E = EMERGENCY

F = ARC FAULT PROTECTED BY BREAKER IN PANEL

G = GROUND FAULT CIRCUIT INTERRUPTER

H = HOSPITAL GRADE

K = CHILD RESISTANT COVER

L = ISOLATED GROUND

P = PENDANT MOUNTED WITH CORD GRIPS. VERIFY PENDANT

LENGTH

R1 = HALF SWITCHED BY OCCUPANCY SENSOR RELAY

R2 = FULLY SWITCHED BY OCCUPANCY SENSOR RELAY

S = SPLIT WIRED

T = TAMPER RESISTANT SHUTTERED RECEPTACLE

U = USB PORT(S)

W = WEATHERPROOF CONTINUOUS USE COVER, GFCI PROTECTED,

WITH WEATHER-RESISTANT RECEPTACLE

DUPLEX RECEPTACLE, FLUSH FLOOR

DOUBLE DUPLEX RECEPTACLE, FLUSH FLOOR

DOUBLE DUPLEX RECEPTACLE. SEE LETTER CODE LIST AT DUPLEX

RECEPTACLE FOR OPTIONS

EQUIPMENT ELECTRICAL CONNECTION

SPECIAL PURPOSE RECEPTACLE. LETTER CODE DENOTES

RECEPTACLE CONFIGURATION

LX-XXR = NEMA CONFIGURATION TWIST-LOCK RECEPTACLE

X-XXR = NEMA CONFIGURATION STRAIGHT BLADE RECEPTACLE

P = PENDANT MOUNT WITH CORD GRIPS. VERIFY PENDANT LENGTH

X = COORDINATE RECEPTACLE CONFIGURATION WITH EQUIPMENT

BEING SUPPLIED

CEILING MOUNTED OCCUPANCY SENSOR

P = PASSIVE INFRARED

D = DUAL TECHNOLOGY

U = ULTRASONIC, 360 DEG RANGE

H = ULTRASONIC, HALLWAY PATTERN

v (LOWERCASE) = VACANCY CONTROL DESIGNATION

WALL MOUNTED OCCUPANCY SENSOR

P = PASSIVE INFRARED

D = DUAL TECHNOLOGY

v (LOWERCASE) = VACANCY CONTROL DESIGNATION

WALL MOUNTED OCCUPANCY SENSOR/SWITCH

S = PASSIVE INFRARED WITH INTEGRAL "OFF" SWITCH

T = DUAL RELAY PASSIVE INFRARED WITH TWO INTEGRAL "OFF"

SWITCHES

D = PASSIVE INFRARED WITH INTEGRAL DIMMER TO OFF.

v (LOWERCASE) = VACANCY CONTROL DESIGNATION

MULTIPLE CHANNEL SURFACE METAL RECEPTACLE RACEWAY

WITH LOW VOLTAGE DIVIDERS, LENGTH AND RECEPTACLES AS

INDICATED

PHOTO ELECTRIC SWITCH

D = CONTINUOUS DIMMING PHOTOCELL

S = SWITCHED PHOTOCELL

SINGLE POLE SWITCH

2 = DOUBLE POLE SWITCH

3 = THREE-WAY SWITCH

4 = FOUR-WAY SWITCH

a THRU z (LOWERCASE) = LUMINAIRE CONTROL DESIGNATION

D = DIMMER

F = FAN SPEED CONTROL

K = KEY OPERATED SWITCH

L = LIGHTED HANDLE

M = MANUAL MOTOR STARTER WITH THERMAL OVERLOAD

P = SWITCH WITH PILOT LIGHT

S = SENTRY SWITCH

T = INTERVAL TIMER

W = WEATHERPROOF SWITCH

V = LOW VOLTAGE SWITCH

Telecommunications

RACEWAY ONLY DATA/TELEPHONE OUTLET. PROVIDE DOUBLE

GANG BACK BOX AND SINGLE GANG ADAPTER PLATE WITH 1" C.

AND PULLSTRING TO ACCESSIBLE CEILING SPACE.

(MULTIPLE LETTERS INDICATE MULTIPLE OPTIONS)

A = ABOVE COUNTER

C = CEILING MOUNTED ABOVE ACCESSIBLE CEILING

F = FLUSH CEILING MOUNTED

R = SURFACE MOUNTED ON RACEWAY

RACEWAY ONLY TELEPHONE OUTLET. PROVIDE DOUBLE GANG

BACK BOX AND SINGLE GANG ADAPTER PLATE WITH 3/4" C. AND

PULLSTRING TO ACCESSIBLE CEILING SPACE. SEE LETTER CODE

LIST AT DATA/TELEPHONE OUTLET FOR OPTIONS.

Room Name Type of Controls Control Functions

Exterior Structure Daylight sensor, wall switch override. Manual on/auto-off. Dimming. Lighting at 100% brightness from dusk until 10pm, then dim to 50% brightness from 10pm until dawn.

GENERAL NOTES:

LIGHTING CONTROL MATRIX

1. Basis of design system is WaveLinx.

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

LI

GH

TI

NG

C

ON

TR

OL

M

AT

RI

X

E0.2

PE

RM

IT

/B

ID

S

ET

/0

8/

116'-8 7/8"

145'-2 3/8"

J

F

J(E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E)

(E)

(E)

(E) (E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E) (E)

(E)(E)

ED2.0

HEADGATE MOTOR

(X)

GENERATOR

(E)

(E)

(X)

(X)

OPEN/CLOSE

BUTTON

(E)

(E) (E) (E) (E)

FLUME GATE CONTROLS

KEYPAD

START/STOP

(E)

(E)

PUMP

(E)

(E)

(X)

(E)

(E)

(E)

(E)

(E)

(E)

(X)

(X) 60 HP MOTOR

(E) 20 HP MOTOR

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

DE

M

OL

IT

IO

N

FL

OO

R

PL

AN

B

AS

EM

EN

T

LE

VE

L E

LE

CT

RI

CA

L

ED2.0

PE

RM

IT

/B

ID

S

ET

0' 4' 8' 16'

1/8" = 1'-0"

1 DEMOLITION FLOOR PLAN - BASEMENT LEVEL - ELECTRICAL NORTH

NOT TO SCALE

2 Meter & Disconnect

SHEET KEYNOTES

1.

2.

3.

4.

5.

6.

7.

8.

DEMO EXISTING DEVICES LOCATED IN HATCHED REGION

INCLUDING CONDUIT AND CONDUCTORS BACK TO SOURCE.

PATCH AND PAINT AS REQUIRED TO MATCH EXISTING EXTERIOR.

EXISTING MOTOR, START/STOP CONTROLS, AND CONTROL

WIRING TO REMAIN. REMOVE CONDUCTORS BACK TO SOURCE.

REFER TO DRAWING E2.0 FOR NEW CIRCUTING INFORMATION

AND MODIFY CONDUITS AS REQUIRED TO NEW PANELBOARD..

EXISTING GENERATOR HAS BEEN DECOMMISSIONED AND NO

LONGER IN OPERATION. REMOVE ANY CONDUIT AND

CONDUCTORS ASSOCIATED WITH THE GENERATOR BACK TO

THE SOURCE. GENERATOR TO BE REMOVED FROM THE

BUILDING. CONFIRM WITH OWNER IF GENERATOR SHOULD BE

TURNED OVER TO THEM OR REMOVED FROM SITE.

REMOVE (E) 60HP CONDUIT, CONDUCTORS, DISCONNECTS, AND

CONTROLS BACK TO SOURCE. CONFIRM WITH OWNER IF MOTOR

SHOULD BE TURNED OVER TO THEM OR REMOVED FROM SITE.

MAINTAIN FUNCTIONALITY OF FLUME GATE CONTROLS, KEYPAD

OVERRIDE, AND START/STOP CONTROL WIRING.

POWER AND CONTROL CONDUITS AND WIRING TO PUMP

CONTROL PANEL IN MAIN ELECTRICAL ROOM ARE EXISTING TO

REMAIN. REFER ENLARGED PLAN 1/E4.4 FOR LOCATION OF PUMP

CONTROL PANEL.

EXISTING 20 HP MOTOR TO REMAIN. EXISTING SOFT STARTER

FOR THIS MOTOR WILL BE RELOCATED TO THE MAIN

ELECTRICAL ROOM. REMOVE CONDUCTORS FROM MOTOR TO

SOFT STARTER AND BACK TO SOURCE. REFER TO DRAWING

1/E4.4 FOR NEW LOCATION OF SOF STARTER. EXTEND CONTROL

WIRING AND CONDUIT AS REQUIRED TO NEW LOCATION. MODIFY

POWER CONDUITS AS REQUIRED TO RE-ROUTE TO NEW

LOCATION.

REMOVE MOTOR CONDUIT, CONDUCTORS, DISCONNECTS, AND

CONTROLS BACK TO SOURCE. CONFIRM WITH OWNER IF MOTOR

SHOULD BE TURNED OVER TO THEM OR REMOVED FROM SITE.

GENERAL SHEET NOTES

A.

B.

DEVICES NOTED WITH AN (E) ARE EXISTING TO REMAIN AND NO

MODIFCATIONS ARE REQUIRED, UNLESS NOTED OTHERWISE.

DEVICES NOTED WITH AN (X) ARE TO BE REMOVED ALONG WITH

CONDUIT AND CONDUCTORS BACK TO THE SOURCE, UNLESS

NOTED OTHERWISE.

/0

J

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)(E)

(E)

(E)

(E)

(E) (E)

(E) (E)

(E)

(E)

(E)

(E)

(E)(E)

(E)

(E)

(E)

(E)

(E) (E)(E)(E)(E)(E)

(E) (E)

(E)

(E)

(E) (E) (E)

(E)(E)(E)

(E) (E)

(E)(E)

(E)

(E)(E)

(E) (E)

(E)

(E)

(E)(E)

(E) (E)

(E) (E)

(E)

(E)

(E)

(E) (E) (E)

(E)

(E)

(E) UTILITY POLE

(X) GENERATOR

CONTROLLER

(E)

(E)

(E)

(E)

E4.3

E4.5

E4.1

E4.2

E4.4

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E) (E)

(E)

HMI

(E)

(E)

(E)

(E)

FACP

(E) (E)

ED2.1

(E)

(E) (E) (E)

OUTDOOR STRUCTURE

(NOT TO SCALE)

(X)

(X)

(X)

(X)

(E)

(E)

(E)

(E) (E)(E)

(E)

(E)

(E)

(E)

(E)

(X)

(E) (E)

(E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

M

(X) UTILITY METER

(X)

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

DE

M

OL

IT

IO

N

FL

OO

R

PL

AN

F

IR

ST

F

LO

OR

E

LE

CT

RI

CA

L

ED2.1

PE

RM

IT

/B

ID

S

ET

0' 4' 8' 16'

1/8" = 1'-0"

1 DEMOLITION FLOOR PLAN - FIRST FLOOR - ELECTRICAL

NORTH

SHEET KEYNOTES

1.

2.

3.

DEMO EXISTING DEVICES LOCATED IN HATCHED REGION.

BANK OF (6) SINGLE-POLE LIGHT SWITCHES. (3) SWITCHES

APPEAR TO BE IN OPERATION AND (3) NOT IN OPERATION.

EXTEND CONDUIT AND CONTROL WIRING AS REQUIRED TO NEW

SWITCH LOCATIONS. SEE E2.1 FOR MORE INFORMATION.

REMOVE DISCONNECT, CONDUCTORS AND CONDUCTORS FOR

WATER HEATER BACK TO SOURCE.

NOT TO SCALE

2 Weatherhead and Utility Meter

GENERAL SHEET NOTES

A.

B.

DEVICES NOTED WITH AN (E) ARE EXISTING TO REMAIN AND NO

MODIFCATIONS ARE REQUIRED, UNLESS NOTED OTHERWISE.

DEVICES NOTED WITH AN (X) ARE TO BE REMOVED ALONG WITH

CONDUIT AND CONDUCTORS BACK TO THE SOURCE, UNLESS

NOTED OTHERWISE.

/0

116'-8 7/8"

145'-2 3/8"

J

F

F

F

J(E) (E)

(E)

(E) (E)

(E)

(E)

(E)

(E) (E)

(E) (E)

(E) (E) (E)

(E)

(E)

(E)

(E)

(E) (E) (E)

(E)

(E)

(E)

(E)

(E)

(E)(E)

(E)

(E)

(E)

G

G

GEN-17.

GEN-17.

OPEN/CLOSE

BUTTON

(E)

FLUME GATE CONTROLS

KEYPAD

START/STOP

(E)

(E) (E) (E)

GEN-6.

(E)

(E)

START/STOP

START/STOP

PUMP

(E) (E)

G

LP-WS-17.

GEN-17.

(E)

GEN-7,9,11.

GEN-1,3,5.

C (E)

C (E)

(E)

GEN-17.

(E)

C,W

GEN-17.

GEN-17.

a a

LP-WS-24.

(E) PORTABLE GENERATOR

CORD AND PLUG.

UP TO (E) MANUAL

TRANSFER SWITCH LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

FL

OO

R

PL

AN

B

AS

EM

EN

T

LE

VE

L E

LE

CT

RI

CA

L

E2.0

PE

RM

IT

/B

ID

S

ET

0' 4' 8' 16'

1/8" = 1'-0"

1 FLOOR PLAN - BASEMENT LEVEL - ELECTRICAL

NORTH

GENERAL SHEET NOTES

A.

B.

DEVICES NOTED WITH AN (E) ARE EXISTING TO REMAIN AND NO

MODIFCATIONS ARE REQUIRED, UNLESS NOTED OTHERWISE.

DEVICES NOTED WITH AN (E) ALONG WITH A PANEL AND CIRCUIT

NUMBER NEXT TO THEM ARE EXISTING DEVICES CIRCUITED TO

A NEW PANELBOARD.

/0

E4.4

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E) (E)

(E)

(E)

(E)(E)

(E) (E)

(E)(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E) (E)

(E) (E) (E) (E) (E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)(E)

(E)

(E) (E)

(E)

(E)(E)(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)(E)

(E)

(E)

(E)

E4.3

(E)

(X)

(E)

(E)

COMPUTER

(E)

(E)

(E)

(E)

(E)(E)

(E)

(E) (E)

(E) (E) (E)

HMI

(E)

(E) (E)

MAIN SERVICE DISCONNECT

TO THOMPSON'S GARAGE PANEL

LP-WS-5.

LP-WS-5.

LP-WS-5.

LP-WS-5.

LP-WS-7.

LP-WS-7.

LP-WS-7.

LP-WS-7.

LP-WS-9.

GEN-24.

GEN-24.

LP-WS-11.

GEN-18.LP-WS-13. LP-WS-11.

GEN-18.

LP-WS-13.

LP-WS-11.

GEN-12.

LP-WS-15.

FACP

(E)

GEN-23.

(E)

(E)

(E) TRACK

(E)

(E)

(E)

(E)

(E)(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E) (E) (E)

W

SWITCHED RECEPTACLE FOR PORTABLE FLOOD LIGHT

OUTDOOR STRUCTURE

(NOT TO SCALE)

WD

A1 A1 A1 A1 A1 A1 A1 A1 A1

A1 A1 A1 A1 A1 A1 A1 A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1 A1 A1 A1

A1

A1

A1

A1

A1

A1

A1 A1

A1

A1

A1 A1 A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1 A1A1

A1

A1

A1

A1

A1

A1

4TYP.

5TYP.

B1

B1

B1

B1 B1

B1

LP-WS-15.

LP-WS-5.

LP-WS-19.

LP-WS-19.

L2-3.L2-3.

L2-3. L2-3. L2-3.

L2-3.

D a bc

(E)

(E)

(E)

(E)

(E)

(E) (E)

(E)(E)

E4.4

E4.3

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK

(E) TRACK (E) TRACK

M

CT CABINET

UTILITY METER

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

FL

OO

R

PL

AN

F

IR

ST

F

LO

OR

E

LE

CT

RI

CA

L

E2.1

PE

RM

IT

/B

ID

S

ET

0' 4' 8' 16'

1/8" = 1'-0"

1 FLOOR PLAN - FIRST FLOOR - ELECTRICAL

NORTH

SHEET KEYNOTES

1.

2.

3.

4.

5.

6.

NEW CONDUCTORS IN NEW CONDUIT TO BLACK ELECTRICAL

CLOSET. PROVIDE 4 #2 CU, 1 #8 CU GND., IN 1-1/4" C.

NEW CONDUCTORS IN EXISTING CONDUIT TO THOMSON'S

GARAGE. INTERCEPT INCOMING CONDUIT AS REQUIRED FROM

MAIN ELECTRICAL ROOM. PROVIDE 4 #2 CU, 1 #8 CU GND.

EXISTING WALL MOUNTED ON DEMAND WATER HEATER.

LUMINAIRE TYPE A1: COOPER LIGHTING, HALO 815MED30FL927SL

TRACK HEADS, OWNER FURNISHED CONTRACTOR INSTALLED.

LUMINAIRE TYPE B1: PROVIDE COOPER LIGHTING, VAPORTITE

4VT3-SL3C3-G-UNV-MED-3000K OR APPROVED EQUAL.

PROVIDE WEATHERPROOF COVER.

GENERAL SHEET NOTES

A.

B.

DEVICES NOTED WITH AN (E) ARE EXISTING TO REMAIN AND NO

MODIFCATIONS ARE REQUIRED, UNLESS NOTED OTHERWISE.

DEVICES NOTED WITH AN (E) ALONG WITH A PANEL AND CIRCUIT

NUMBER NEXT TO THEM ARE EXISTING DEVICES CIRCUITED TO

A NEW PANELBOARD.

/0

60'-3"

(E) (E)

(E)

(E)

(E) (E)

(E)

(E)

G

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

FL

OO

R

PL

AN

S

EC

ON

D

FL

OO

R E

LE

CT

RI

CA

L

E2.2

PE

RM

IT

/B

ID

S

ET

0' 4' 8' 16'

1/8" = 1'-0"

1 FLOOR PLAN - SECOND FLOOR - ELECTRICAL

NORTH

SHEET KEYNOTES

1. CONNECT TO NEAREST 120V CONVENIENCE RECEPTACLE

CIRCUIT W/ (2)#12, #12G IN 3/4" C.

GENERAL SHEET NOTES

A. DEVICES NOTED WITH AN (E) ARE EXISTING TO REMAIN AND NO

MODIFCATIONS ARE REQUIRED, UNLESS NOTED OTHERWISE.

/0

(E)

(E)

(E)

(E)

(E)

(E)

(E)

(E)

G

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

FL

OO

R

PL

AN

T

HI

RD

F

LO

OR

E

LE

CT

RI

CA

L

E2.3

PE

RM

IT

/B

ID

S

ET

0' 4' 8' 16'

1/8" = 1'-0"

1 FLOOR PLAN - THIRD FLOOR - ELECTRICAL

NORTH

GENERAL SHEET NOTES

A. DEVICES NOTED WITH AN (E) ARE EXISTING TO REMAIN AND NO

MODIFCATIONS ARE REQUIRED, UNLESS NOTED OTHERWISE.

SHEET KEYNOTES

1. CONNECT TO NEAREST 120V CONVENIENCE RECEPTACLE

CIRCUIT W/ (2)#12, #12G IN 3/4" C. 11

/0

(E)WOOD

COLUMN

G

TO FLOOR

BELOW

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

FL

OO

R

PL

AN

F

OU

RT

H

FL

OO

R E

LE

CT

RI

CA

L

E2.4

PE

RM

IT

/B

ID

S

ET

0' 4' 8' 16'

1/8" = 1'-0"

1 FLOOR PLAN - FOURTH FLOOR - ELECTRICAL

NORTH

GENERAL SHEET NOTES

A. DEVICES NOTED WITH AN (E) ARE EXISTING TO REMAIN AND NO

MODIFCATIONS ARE REQUIRED, UNLESS NOTED OTHERWISE.

SHEET KEYNOTES

1. CONNECT TO NEAREST 120V CONVENIENCE RECEPTACLE

CIRCUIT W/ (2)#12, #12G IN 3/4" C. 11

/0

E4.1

E4.1

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

EN

LA

RG

ED

P

LA

NS

E

LE

CT

RI

CA

L

E4.1

PE

RM

IT

/B

ID

S

ET

0' 1' 2' 4'

1/2" = 1'-0"

1 Level 1 - Enlarged - Green Electrical Room

NOT TO SCALE

2 Green Electrical Room North & East Walls

NOT TO SCALE

3 Green Electrical Room South Wall

SHEET KEYNOTES

1.

2.

3.

DEVICES LOCATED WITHIN THE HATCHED REGION ARE TO BE

REMOVED ALONG WITH ASSOCIATED CONDUIT AND

CONDUCTORS BACK TO THE SOURCE, UNLESS NOTED

OTHERWISE.

RELOCATE MOTOR STARTER CONTROL PANEL TO MAIN

ELECTRICAL ROOM. PROVIDE 3#8 CU, 1#10 CU GND., IN 3/4"C

FROM CONTROL PANEL TO MOTOR.

CONNECT AND EXTEND CONDUCTORS FOR CIRCUITS ON LOAD

CENTER TO PANEL 'LP-WS'.

/0

E4.2

E4.2

E4.2

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

EN

LA

RG

ED

P

LA

NS

E

LE

CT

RI

CA

L

E4.2

PE

RM

IT

/B

ID

S

ET

0' 1' 2' 4'

1/2" = 1'-0"

1 Level 1 - Enlarged - Black Electrical Room

NOT TO SCALE

2 Black Electrical Room West Wall

NOT TO SCALE

3 Black Electrical Room South Wall

NOT TO SCALE

4 Black Electrical Room East Wall

SHEET KEYNOTES

1. DEVICES LOCATED WITHIN THE HATCHED REGION ARE TO BE

REMOVED ALONG WITH ASSOCIATED CONDUIT AND CONDUCTORS

BACK TO THE SOURCE, UNLESS NOTED OTHERWISE.

/0

E4.3

'INV' 2

(E) PANEL 'L2'

(E) PANEL 'L1'

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

EN

LA

RG

ED

P

LA

NS

E

LE

CT

RI

CA

L

E4.3

PE

RM

IT

/B

ID

S

ET

0' 1' 2' 4'

1/2" = 1'-0"

1 Level 1 - Enlarged - Demo Blue Electrical Room

NOT TO SCALE

2 Blue Electrical Room West Wall

SHEET KEYNOTES

1.

2.

DEVICES LOCATED WITHIN THE HATCHED REGION ARE TO BE

REMOVED ALONG WITH ASSOCIATED CONDUIT AND CONDUCTORS

BACK TO THE SOURCE, UNLESS NOTED OTHERWISE.

DEMOLISH EXISTING 1.5KVA INVERTER AND REPLACE WITH NEW 1.5

KVA INVERTER. RECONNECT EXISTING CONDUIT AND CONDUCTORS

TO NEW INVERTER. REFER TO SINGLE LINE DIAGRAM FOR INVERTER

SPECIFICATION INFORMATION.

0' 4' 8' 16'

1/2" = 1'-0"

3 Level 1 - Enlarged - New Blue Electrical Room

GENERAL SHEET NOTES

A. DEVICES NOT SHOWN WITHIN THE HATCHED REGION ARE

EXISTING TO REMAIN.

/0

E4.4

E4.4

(E) PANEL 'LP-WS'

(E) CONTROL PANEL 'PCP'

(R) MOTOR STARTER CONTROL PANEL

(E) MTS

MAIN-2,4,6.

PANEL 'MAIN'

PANEL 'GEN'

MAIN-21,23,25. LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

EN

LA

RG

ED

P

LA

NS

E

LE

CT

RI

CA

L

E4.4

PE

RM

IT

/B

ID

S

ET

0' 1' 2' 4'

1/2" = 1'-0"

1 Level 1 - Enlarged - Demo Main Electrical Room

NOT TO SCALE

2 Main Electrical Room East Wall

NOT TO SCALE

3 Main Electrical Room West Wall

SHEET KEYNOTES

1.

2.

DEVICES LOCATED WITHIN THE HATCHED REGION ARE TO BE

REMOVED ALONG WITH ASSOCIATED CONDUIT AND

CONDUCTORS BACK TO THE SOURCE, UNLESS NOTED

OTHERWISE.

MOTOR STARTER CONTROL PANEL RELOCATED FROM GREEN

ELECTRICAL ROOM AS NOTED ON DRAWING 2/E4.1. EXTEND

POWER AND CONTROL WIRING TO 20HP MOTOR IN BASEMENT.

0' 4' 8' 16'

1/2" = 1'-0"

4 Level 1 - Enlarged - New Main Electrical Room

GENERAL SHEET NOTES

A. DEVICES NOT SHOWN WITHIN THE HATCHED REGION ARE

EXISTING TO REMAIN.

/0

E4.5

1 2

1 2 1 2

1 2

1 2

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

EN

LA

RG

ED

P

LA

NS

E

LE

CT

RI

CA

L

E4.5

PE

RM

IT

/B

ID

S

ET

0' 1' 2' 4'

1/2" = 1'-0"

1 Level 1 - Enlarged - Electrical Closet

NOT TO SCALE

2 Electrical Closet Overview

NOT TO SCALE

3 Electrical Closet 1

NOT TO SCALE

4 Electrical Closet 2

NOT TO SCALE

6 Electrical Closet 4

NOT TO SCALE

5 Electrical Closet 3

E4.5

E4.5

E4.5

E4.5

SHEET KEYNOTES

1.

2.

DEVICES LOCATED WITHIN THE HATCHED REGION ARE TO BE

REMOVED ALONG WITH ASSOCIATED CONDUIT AND

CONDUCTORS BACK TO THE SOURCE, UNLESS NOTED

OTHERWISE.

CONTRACTOR TO TRACE OUT AND IDENTIFY EACH PIECE OF

EQUIPMENT CONNECTED TO THE DISCONNECTS AND

STARTERS BEING DEMOLISHED. ONCE ALL EQUIPMENT

AFFECTED BY THE DEMOLITION HAS BEEN IDENTIFIED,

CONTRACTOR TO CONFIRM WITH ONWER EACH PIECE OF

EQUIPMENT THEY WOULD LIKE TO HAVE REMOVED AND

REMOVE THE EQUIPMENT AS WELL AS THE ASSOCIATED

CONDUIT AND CONDUCTORS BACK TO SOURCE.

GENERAL SHEET NOTES

A. DEVICES NOT SHOWN WITHIN THE HATCHED REGION ARE

EXISTING TO REMAIN.

/0

(E) UTILITY POLE

TO THOMPSON'S

GARAGE

FULL LENGTH

AVAILABLE FAULT CURRENT: 16,040 A

SHORT CIRCUIT CURRENT RATING: 22,000 A

ØA

ØC

NN

ØC

ØB(HIGH)

ØA

POLE MOUNTED

POWER COMPANY

TRANSFORMERS

240/120 VOLT, 3 PHASE, 4 WIRE CLOSED DELTA

(E) SOFT STARTER TO

BE RELOCATED TO

MAIN ELECTRICAL

ROOM.

400 AMP BUS

#1 BARE COPPER

GROUND BUS

MAIN DISTRIBUTION PANELBOARD (MAIN)

1253 2003

20FT., 3/4" DIAMETER

MINIMUM REBAR IN

CONCRETE

FOOTING/

FOUNDATION

#4 COPPER

#6 COPPER

#1

M

1.

2.

3.

4.

5.

CURRENT TRANSFORMER/TERMINAL CABINET PER POWER

COMPANY REQUIREMENTS.

PROVIDE CENTRAL LIGHTING INVERTER RATED FOR 1.5KVA,

120V INPUT, 120V OUTPUT, WITH (3) OUTPUT CIRCUITS. BOD

MYERS ILLUMINATOR IE 1-IE-1-S-BA2003.

REFER TO PANEL SCHEDULE FOR ADDITIONAL BRANCH

CIRCUITING INFORMATION.

PROVIDE 100% RATED BREAKER.

PROVIDE CURRENT LIMITING FUSES RATED FOR 22KAIC.

DETAIL KEYNOTES

GENERAL DETAIL NOTES

A. CALCULATED VALUES FOR AVAILABLE FAULT CURRENT ARE

SUITABLE FOR PLAN REVIEW PURPOSES BUT ARE NOT

CONSIDERED ACCURATE FOR ACTUAL INSTALLED FEEDER

ROUTING. UPDATE THE AS-BUILT DRAWING SET AT THE

CONSTRUCTION SITE WITH RESULTS OF CALCULATIONS FOR

FAULT CURRENT BASED ON ACTUAL FEEDER LENGTHS AND

ROUTING USING RESULTS OF LICENSED SOFTWARE PER

APPROVED ELECTRICAL DISTRIBUTION SYSTEM STUDY

(SECTION 26 05 73).

BUILDING

STEEL

COLD

WATER

PIPE

10'-0"

GROUND

RODS AT

20'-0"C/C

100A 2P

METER BASE PER

POWER COMPANY

REQUIREMENTS

1-1/2"C. WITH

PULL WIRE

CURRENT

TRANSF.

CABINET

400A 3P

125A 2P

150A 2P

N

(N) WEATHERHEADS PER

UTILITY COMPANY REQUIREMENTS

AVAILABLE FAULT CURRENT: 16,529 A

SHORT CIRCUIT CURRENT RATING: 22,000 A

240/120 VOLT, 3 PHASE, 4 WIRE CLOSED DELTA

MAIN SERVICE DISCONNECT

100A 3P

(E) 20 HP

(E)

100A 3P

INTEGRAL SURGE

PROTECTION DEVICE

(E) MANUAL TRANSFER

SWITCH

240V, 3POLE, 100 AMPEXISTING CONDUIT,

CONDUCTORS, AND

PLUG

OPTIONAL

STANDBY

BRANCH

F5

PANEL

'GEN'

100 A

13188 AFC

INVERTER

'INV'

2799 AFC

(E)PANEL

'LP-WS'

125 A

13894 AFC

(E)PANEL

'L1'

200 A

8482 AFC

(E)PANEL

'L2'

200 A

8129 AFC

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

ON

E-

LI

NE

D

IA

GR

AM

E

LE

CT

RI

CA

L

E5.0

PE

RM

IT

/B

ID

S

ET

A,C,S,X A=Aluminum C=Conduit only S=Service secondary X=Seperately derived system

FEEDER SCHEDULE

1003 3 #2 CU, 1 #8 CU GND., IN 1 1/4" C.

1004 4 #2 CU, 1 #8 CU GND., IN 1 1/4" C.

1253 3 #1 CU, 1 #6 CU GND., IN 1 1/4" C.

2003 3 #3/0 CU, 1 #6 CU GND., IN 2" C.

4004 2 SETS OF (4 #3/0 CU, 1 #2 CU GND., IN 2" C.)

0' 4' 8' 16'

NO SCALE

1 ONE-LINE POWER DISTRIBUTION DIAGRAM

Disclaimer: Interface Engineering, Inc. has contacted the utilities but has not received in writing the final requirements from the power utility. These drawings indicate our best estimation of their requirements. Prior to any construction contact the utility and obtain in writing their requirements.

3. Obtain fault current from utility. Estimated at 18,043 amps based on 225kVA transformer at 3% impedance.

2. All service installation work shall be in strict compliance with the requirements of the serving utilities.

1. Contact and coordinate all requirements and responsibilities with serving utility companies prior to submitting bid.

Notes:

Reported Fault Current at Transformer Note 3

Electric Room Door Lock Box (obtain from power company)

Meter X

Meter Base X

C/T's X

C/T Enclosure X

Secondary Conductors X

Secondary Conduit/Weaterheads X

Transformer Connections X

Bollards

Transformer Pad / Vault

Transformer X

Trenching and Backfill

Primary Conductors X

Primary Conduit Power Utility:

Cori Perez Pacific Power Phone:(503) - 967-6136

Contractor Utility Contacts:

Division of Responsibility Incoming Electrical Service

/0

(E) MAXIMUM DEMAND: 19.00 KW

POWER FACTOR (0.9): 21.11 KVA

+25% SAFETY FACTOR: 26.39 KVA

+ADDED (NEW) DEMAND LOAD: 4.10 KVA

TOTAL NEW DEMAND LOAD: 30.49 KVA

TOTAL AMPS (240V, 3PHASE): 73.34 AMPS

LOAD SUMMARY

AT EXISTING 00A, 240/120V, 3 PH, 4W SERVICE.

MAXIMUM 24-MONTH PEAK DEMAND WAS 19 KW, AS PER

SERVING UTILITY METER #74 364 259

LEAVE BLANK FOR CITY APPROVAL STAMPLEAVE BLANK FOR CITY APPROVAL STAMP

OR

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

SC

HE

DU

LE

S E

LE

CT

RI

CA

L

E6.0

PE

RM

IT

/B

ID

S

ET

Total NEC Demand Current: 37.1 A R 3440.0 100.00% 3440.0 Total Connected Current: 34.0 A G 580.0 100.00% 580.0 Total NEC Demand: 15430.5 VA Motor 9892.0 112.50% 11128.5 Total Connected Load: 14137.6 VA L 225.6 125.00% 282.0

Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC Table... W = Water Heater (125%) EV = Electric Vehicle Changer R = Receptacles (to 10kVA100%, over 10 kVA... G = General Load (Non-continuous) (100%) L = Lighting (125%) H = Heating (100%)

Motor (125% largest Motor + 100% remaining... K = Kitchen (Demand as per NEC Table 220.56) C = Continuous Load (125%) X = X-Rays (Demand per NEC...

Load Type Definitions:

1. EXISTING LOAD ON NEW BREAKER.

Notes:

Total Connected load Ph. C 55 A Total Connected load Ph. B 27 A Total Demand Load: 15.4 kVA 37.1 A Total Connected load Ph. A 35 A Panel Connected Load: 14.1 kVA 34.0 A

41 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 42

39 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 40

37 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 38

35 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 36

33 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 34

31 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 32

29 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 30

27 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 28

25 -- -- -- -- -- 0 -- 1 -- -- BUSSED SPACE 26

23 -- -- -- -- -- 0 -- 1 -- -- BUSSED SPACE 24

21 (E) SOFT STARTER CTRL PNL Motor 100 A 3 1 0 -- 1 -- -- BUSSED SPACE 22

19 -- -- -- -- -- 0 -- 1 -- -- BUSSED SPACE 20

17 -- -- -- -- -- 0 -- 1 -- -- BUSSED SPACE 18

15 (E) THOMPSON'S GARAGE -- 100 A 3 1 0 -- 1 -- -- BUSSED SPACE 16

13 -- -- -- -- -- 226 -- 1 -- -- BUSSED SPACE 14

11 (E) PANEL L1 Spar... 150 A 2 1 0 5,697 -- -- -- -- -- 12

9 BUSSED SPACE -- -- 1 -- 3,297 -- -- -- -- -- 10

7 -- -- -- -- -- 720 3,297 1 3 100 A Moto... PANEL GEN 8 5 (E) PANEL LP-WS Moto... 125 A 2 1 900 0 -- -- -- -- -- 6

3 BUSSED SPACE -- -- 1 -- 0 -- -- -- -- -- 4

1 BUSSED SPACE -- -- 1 -- 0 1 3 60 A Other (E) PCP CONTROL PANEL 2

CKT Description/Location Type C.B. Pole Note A B C A B C

Note Pole C.B. Type Description/Location CKT

Load (VA)

AIC RATING SUPPLIED FROM:

EQUIPMENT RATING: 120/240V, 3PH, 4 WIRE LOCATION:

BUS AMPACITY: 400 A ENCLOSURE: TYPE 1

MAIN CIRCUIT BREAKER MOUNTING: SURFACE Accessories:

PANELBOARD: MAIN

Total NEC Demand Current: 6.8 A Total Connected Current: 6.8 A

Total NEC Demand: 1620.0 VA R 1620.0 100.00% 1620.0 Total Connected Load: 1620.0 VA Motor 0.0 0.00% 0.0

Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC... W = Water Heater (125%) EV = Electric Vehicle Charger R = Receptacles (to 10kVA100%, over 10 kVA 50%) G = General Load (Non-continuous)... L = Lighting (125%) H = Heating (100%) Motor (125% largest Motor + 100% remaining motors) K = Kitchen (Demand as per NEC... C = Continuous Load (125%) X = X-Rays (Demand per NEC 660.6) Load Type Definitions:

1. EXISTING LOADS FROM GREEN ELECTRICAL CLOSET LOAD CENTER ON NEW BREAKER.

2. EXISTIGN LOAD ON NEW BREAKER.

3. EXISTING LOAD ON EXISTING BREAKER.

4. NEW LOAD ON NEW BREAKER.

Notes:

Total Connected load Ph. B 0 A Total Demand... 1.6 kVA 6.8 A Total Connected load Ph. A 8 A Panel... 1.6 kVA 6.8 A

41 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 42

39 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 40

37 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 38

35 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 36

33 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 34

31 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 32

29 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 30

27 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 28

25 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 26

23 SPARE BREAKER -- 20 A 1 0 0 1 1 30 A Motor MOTOR 24

21 SPARE BREAKER -- 20 A 1 0 0 1 1 20 A -- R BASEMENT 22

19 R FLOOD LIGHT/COVER R 20 A 1 4 360 0 1 1 20 A -- PELLETT 20

17 R BASEMENT R 20 A 1 2 0 0 1 1 20 A -- R UPSTAIRS 18

15 R LEVEL 1 R 20 A 1 4 360 0 1 1 20 A -- CHOPPER 16

13 R OFFICE R 20 A 1 4 720 0 1 1 20 A -- R NORTH BASEMENT 14

11 R OFFICE R 20 A 1 2 0 0 1 1 20 A -- R WAREHOUSE 12

9 R OFFICE R 20 A 1 2 0 0 1 1 20 A -- R OFFICE 10

7 R OFFICE R 20 A 1 2 0 0 1 1 20 A -- PUMP 8

5 R OFFICE R 20 A 1 4 180 0 1 1 20 A -- R MILL 6

3 EXISTING LOAD -- 20 A 1 3 0 0 3 1 20 A -- EXISTING LOAD 4

1 SPARE BREAKER -- 20 A 1 0 0 3 1 20 A -- EXISITNG LOAD 2

CKT Description/Location Type C.B. Pole Note A C A C

Note Pole C.B. Type Description/Location CKT

Load (VA)

AIC RATING: PROVIDE CURRENT LIMITING

FUSES

SUPPLIED FROM: MAIN

EQUIPMENT RATING: 120/240 V, 1PH, 3 WIRE LOCATION:

BUS AMPACITY: 125 A ENCLOSURE: TYPE 1

MAIN LUG ONLY MOUNTING: SURFACE Accessories:

(E)PANELBOARD:LP-WS

Total NEC Demand Current: 1.2 A Total Connected Current: 0.9 A

Total NEC Demand: 282.0 VA Total Connected Load: 225.6 VA

L 225.6 125.00% 282.0 Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals

E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC... W = Water Heater (125%) EV = Electric Vehicle Charger R = Receptacles (to 10kVA100%, over 10 kVA 50%) G = General Load (Non-continuous)... L = Lighting (125%) H = Heating (100%) Motor (125% largest Motor + 100% remaining motors) K = Kitchen (Demand as per NEC... C = Continuous Load (125%) X = X-Rays (Demand per NEC 660.6) Load Type Definitions:

1. NEW LOAD ON EXISTING BREAKER.

2. EXISTING LOAD ON EXISTING BREAKER.

Notes:

Total Connected load Ph. B 0 A Total Demand... 0.3 kVA 1.2 A Total Connected load Ph. A 0 A Panel... 0.2 kVA 0.9 A

41 SPARE BREAKER -- 20 A 1 0 0 1 1 20 A Spare INV 42

39 L TRACK BEHIND OFFICE -- 20 A 1 2 0 0 1 20 A -- SPARE BREAKER 40

37 L TRACK BEHIND FENCE -- 20 A 1 2 0 0 1 20 A -- SPARE BREAKER 38

35 L TRACK SOUTH END -- 20 A 1 2 0 0 2 1 20 A -- L TRACK TURN OUT ZONE C 36

33 L TRACK SOUTH END -- 20 A 1 2 0 0 2 1 20 A -- L TRACK TURN OUT ZONE C 34

31 L TRACK NORTH END -- 20 A 1 2 0 0 2 1 20 A -- L TRACK TURN OUT ZONE C 32

29 L TRACK NORTH END -- 20 A 1 2 0 0 2 1 20 A -- L TRACK TURN OUT ZONE C 30

27 SPARE BREAKER -- 20 A 1 0 0 2 1 20 A -- L TRACK WAREHOUSE 2 ZONE B 28

25 SPARE BREAKER -- 20 A 1 0 0 2 1 20 A -- L TRACK WAREHOUSE 2 ZONE B 26

23 R NORTH WAREHOUSE -- 20 A 1 2 0 0 2 1 20 A -- L TRACK WAREHOUSE 2 ZONE B 24

21 R NORTH WAREHOUSE -- 20 A 1 2 0 0 2 1 20 A -- L TRACK WAREHOUSE 2 ZONE B 22

19 R WAREHOUSE 2 -- 20 A 1 2 0 0 2 1 20 A -- L TRACK WAREHOUSE 2 ZONE B 20

17 SPARE BREAKER -- 20 A 1 0 0 2 1 20 A -- L TRACK WAREHOUSE 2 ZONE B 18

15 OFFICE LIGHTS,S MILL -- 20 A 1 2 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 16

13 R LUNCHROOM -- 20 A 1 2 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 14

11 FLOORBOX S TAILRACE -- 20 A 1 2 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 12

9 FLOORBOX MIDDLE TAILRACE -- 20 A 1 2 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 10

7 FLOORBOX N TAILRACE -- 20 A 1 2 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 8

5 SPARE BREAKER -- 20 A 1 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 6

3 R NORTH TAILRACE -- 20 A 1 2 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 4

1 SALT ROOM LIGHTS -- 20 A 1 2 0 0 2 1 20 A -- L TRACK N WAREHOUSE ZONE A 2

CKT Description/Location Type C.B. Pole Note A C A C

Note Pole C.B. Type Description/Location CKT

Load (VA)

AIC RATING: 22kAIC SUPPLIED FROM: MAIN

EQUIPMENT RATING: 120/240 V, 1PH, 3 WIRE LOCATION:

BUS AMPACITY: 200 A ENCLOSURE: TYPE 1 Provide Feed -Thru Lugs MAIN LUG ONLY MOUNTING: SURFACE Accessories:

(E)PANELBOARD:L1

Total NEC Demand Current: 1.2 A Total Connected Current: 0.9 A

Total NEC Demand: 282.0 VA Total Connected Load: 225.6 VA

L 225.6 125.00% 282.0 Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals

E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC... W = Water Heater (125%) EV = Electric Vehicle Charger R = Receptacles (to 10kVA100%, over 10 kVA 50%) G = General Load (Non-continuous)... L = Lighting (125%) H = Heating (100%) Motor (125% largest Motor + 100% remaining motors) K = Kitchen (Demand as per NEC... C = Continuous Load (125%) X = X-Rays (Demand per NEC 660.6) Load Type Definitions:

1. NEW LOAD ON EXISTING BREAKER.

2. EXISTING LOAD ON EXISTING BREAKER.

Notes:

Total Connected load Ph. B 0 A Total Demand... 0.3 kVA 1.2 A Total Connected load Ph. A 0 A Panel... 0.2 kVA 0.9 A

41 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 42

39 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 40

37 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 38

35 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 36

33 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 34

31 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 32

29 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 30

27 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 28

25 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 26

23 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 24

21 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 22

19 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 20

17 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 18

15 SPARE BREAKER -- 20 A 1 0 -- 1 -- -- BUSSED SPACE 16

13 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 14

11 OFFICE RECEPTACLES -- 20 A 1 2 0 0 1 20 A -- SPARE BREAKER 12

9 OFFICE RECEPTACLES -- 20 A 1 2 0 0 1 20 A -- SPARE BREAKER 10

7 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 8

5 SPARE BREAKER -- 20 A 1 0 0 1 20 A -- SPARE BREAKER 6

3 L OUTDOOR COVER LIGHTS L 20 A 1 1 226 0 2 1 20 A -- DRUG ROOM RECEPTACLE 4

1 OUTSIDE LIGHTS PLUG -- 20 A 1 0 0 2 1 20 A -- DRUG ROOM LIGHT 2

CKT Description/Location Type C.B. Pole Note A C A C

Note Pole C.B. Type Description/Location CKT

Load (VA)

AIC RATING: 22kAIC SUPPLIED FROM: L1

EQUIPMENT RATING: 120/240 V, 1PH, 3 WIRE LOCATION:

BUS AMPACITY: 200 A ENCLOSURE: TYPE 1

MAIN LUG ONLY MOUNTING: SURFACE Accessories:

(E)PANELBOARD:L2

22kAIC

/0

EG

ON

P

AR

KS

A

ND

R

EC

RE

AT

IO

N

DE

PA

RT

M

EN

T

P A R K

SO

N

E G

O R S

TA

TE

A P P R O V E D

B Y

C H E C K E D

B Y

D R A W N

B Y

D A

TE

R E V

IS

IO

N

D A

TE

SHEET:

OPRIS#: CONTRACT#:

SH

ED

D, O

RE

GO

N

BO

ST

ON

F

LO

UR

M

IL

L

TH

OM

PS

ON

F

LO

UR

IN

G M

IL

L

EXPIRES: 12/31/25

Ap pr ov er

Ch ec ke r

Au th or

SC

HE

DU

LE

S E

LE

CT

RI

CA

L

E6.1

PE

RM

IT

/B

ID

S

ET

Total NEC Demand Current: 32.5 A Total Connected Current: 29.6 A

R 1820.0 100.00% 1820.0 Total NEC Demand: 13528.5 VA G 580.0 100.00% 580.0 Total Connected Load: 12292.0 VA Motor 9892.0 112.50% 11128.5

Load Type Connected Load NEC Demand Factor NEC Demand Load Panel Totals E = Existing Load 30-day metered (125%) EL = Elevator (Demand as per NEC Table... W = Water Heater (125%) EV = Electric Vehicle Changer R = Receptacles (to 10kVA100%, over 10 kVA... G = General Load (Non-continuous) (100%) L = Lighting (125%) H = Heating (100%)

Motor (125% largest Motor + 100% remaining... K = Kitchen (Demand as per NEC Table 220.56) C = Continuous Load (125%) X = X-Rays (Demand per NEC...

Load Type Definitions:

1. EXISTING LOAD ON NEW BREAKER.

2. NEW LOAD ON NEW BREAKER.

Notes:

Total Connected load Ph. C 47 A Total Connected load Ph. B 27 A Total Demand Load: 13.5 kVA 32.5 A Total Connected load Ph. A 27 A Panel Connected Load: 12.3 kVA 29.6 A

23 FACP G 20 A 1 1 180 540 1 1 20 A R R OFFICE 24

21 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 22

19 SPARE BREAKER -- 20 A 1 0 -- 1 -- -- BUSSED SPACE 20

17 R BASEMENT R 20 A 1 1,2 560 720 2 1 20 A R R OFFICE 18

15 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 16

13 BUSSED SPACE -- -- 1 -- -- 1 -- -- BUSSED SPACE 14

11 -- -- -- -- -- 1,649 200 1 1 20 A G HMI 12

9 -- -- -- -- -- 1,649 -- 1 -- -- BUSSED SPACE 10

7 (E) HEADGATE MOTOR Motor 20 A 3 1 1,649 -- 1 -- -- BUSSED SPACE 8

5 -- -- -- -- -- 1,649 200 1 1 20 A G FLUME GATE CONTROLS 6

3 -- -- -- -- -- 1,649 -- 1 -- -- BUSSED SPACE 4

1 (E) HEADGATE MOTOR Motor 20 A 3 1 1,649 -- 1 -- -- BUSSED SPACE 2

CKT Description/Location Type C.B. Pole Note A B C A B C

Note Pole C.B. Type Description/Location CKT

Load (VA)

AIC RATING: 22kAIC SUPPLIED FROM: MAIN

EQUIPMENT RATING: 120/240V, 3PH, 4 WIRE LOCATION:

BUS AMPACITY: 100 A ENCLOSURE: TYPE 1

MAIN CIRCUIT BREAKER MOUNTING: SURFACE Accessories:

PANELBOARD: GEN

/0

E0.1 - SYMBOL LIST AND GENERAL NOTES - ELECTRICAL
E0.2 - LIGHTING CONTROL MATRIX
ED2.0 - DEMOLITION FLOOR PLAN - BASEMENT LEVEL - ELECTRICAL
ED2.1 - DEMOLITION FLOOR PLAN - FIRST FLOOR - ELECTRICAL
E2.0 - FLOOR PLAN - BASEMENT LEVEL - ELECTRICAL
E2.1 - FLOOR PLAN - FIRST FLOOR - ELECTRICAL
E2.2 - FLOOR PLAN - SECOND FLOOR - ELECTRICAL
E2.3 - FLOOR PLAN - THIRD FLOOR - ELECTRICAL
E2.4 - FLOOR PLAN - FOURTH FLOOR - ELECTRICAL
E4.1 - ENLARGED PLANS - ELECTRICAL
E4.2 - ENLARGED PLANS - ELECTRICAL
E4.3 - ENLARGED PLANS - ELECTRICAL
E4.4 - ENLARGED PLANS - ELECTRICAL
E4.5 - ENLARGED PLANS - ELECTRICAL
E5.0 - ONE-LINE DIAGRAM - ELECTRICAL
E6.0 - SCHEDULES - ELECTRICAL
E6.1 - SCHEDULES - ELECTRICAL

File details come from the government source that posted it. Updated .