ATTACHMENT C - OPTION YEAR 2.pdf
PDF 258 KB Posted
- Attached to
- H259--ELECTRICAL DISTRIBUTION SYSTEM TESTING BASE + 2 OYS Federal contract opportunity
- Solicitation number
- 36C25224Q0416
About this file
This document appears to be an attachment titled "ATTACHMENT C - OPTION YEAR 2.pdf" related to a federal contract opportunity for electrical distribution system testing at the Edward Hines Jr VA Hospital in Hines, IL.
The attachment provides a detailed equipment list for the Option Year 2 period, including information on panelboards, transformers, medium voltage cables, and medium voltage switches that are part of the facility's electrical distribution system. The document contains technical specifications such as manufacturer, model, voltage ratings, amperage ratings, and other details for the various electrical components. This information is likely necessary for the contractor to understand the scope of work required for maintaining and testing the facility's electrical distribution system under the contract.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25224Q0416 0002_1.docx | DOCX document | |
| ATTACHMENT G - Construction Safety Guidebook.pdf | ||
| 36C25224Q0416 0001.docx | DOCX document | |
| ATTACHMENT E - VHA Directive 1028_2020-02-24.pdf | ||
| ATTACHMENT B - OPTION YEAR 1.pdf | ||
| ATTACHMENT D - Contractor VA System Outage Request Form Milwaukee.docx | DOCX document | |
| ATTACHMENT A - BASE YEAR.pdf | ||
| 36C25224Q0416_2.docx | DOCX document | |
| ATTACHMENT F - CONTRACTOR Non-Disclosure Agreement.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
15 | P a g e
Option Year Two:
TYPE PLANT SUBSTATION
EQUIPMENT
POSITION
DEVICE/
FEEDER ID
MANUFACTURER
SYSTEM
VOLTAGE
RATED
VOLTAGE
BUS
AMPS
GROUND
SIZE
NEUTRAL
SIZE
Panelboard North Loop Feeds Panels PNL K Square D 120/240 240 200 4/0 4/0
EQUIPMENT
POSITION
DEVICE/
FEEDER ID
MANUFACTURER
MODEL/
STYLE #
SERIAL /
I.B. NUMBER
UL/
CSA #
PHASE KVA
NUMBER
OF
FEEDERS
/ TAPS
PRIMARY
VOLTS
SECONDARY
VOLTS
TANK /
FUEL
TYPE
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 5 Cooper Power systems 926001211 OA 3 300 5 13200 208 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 1 RTE CP 886003126 OA 3 75 5 13200 208 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 2 RTE CP 836005318 OA 3 500 5 13200 208 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 3 Cutler-Hammer CP 05J253373 OA 3 225 5 13200 208 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers 6 RTE 886003330 OA 3 1000 5 13200 250 / 120
Gas Blanket /
Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 7 Cooper Power systems CP 939002948 OA 3 500 5 13200 208 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers 7? RTE CP 886003187 OA 3 5 13200 208 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 11 Vantran CP 88V2552 OA 1 50 5 13200 120 / 120 Gas Blanket
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 12 RTE CP 886003127 OA 3 75 5 13200 208 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 14 Vantran CP 88V2551 OA 1 38 5 13200 120 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 16 Vantran CP 88V25553 OA 1 50 5 13200 120 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 17 Vantran CP 15V10928 OA 1 75 5 13200 120 / 120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 19 Vantran CP 88V2555 OA 1 75 5 13200 120/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 20 RTE CP 88600316 OA 3 113 5 13200 208/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 27 Vantran CP 98V3728-2 OA 3 75 5 13200 208/120
Gas Blanket /
Mineral Oil
VHAMIWSchwaL Text Box Attachment C
VHAMIWSchwaL
1 Page
16 | P a g e
POSITION
DEVICE/
FEEDER ID
MANUFACTURER
MODEL/
STYLE #
SERIAL /
I.B. NUMBER
UL/
CSA #
PHASE KVA
NUMBER
OF
FEEDERS
/ TAPS
PRIMARY
VOLTS
SECONDARY
VOLTS
TANK /
FUEL
TYPE
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 36 Vantran CP 97V3728-1 OA 3 75 5 13200 208/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 39 Vantran CP 88V2548 OA 1 37.5 5 13200 120/120 Gas Blanket
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 41 RTE 886003186 OA 3 225 5 13200 208/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 41 from HVS-41 Vantran CP 97V3728-3 OA 3 75 5 13200 208/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers 43 GE P492478TXC OA 3 750 5 13200 480/277
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers 49 Vantran CP 88V2556 OA 1 75 5 13200 120/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 62 Vantran CP 88V2557 OA 1 75 5 13200 120/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 97 RTE CP 886003124 OA 3 75 5 13200 208/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 102 Cooper Power 1450005699 KNAN 3 500 5 13200 208/120
Gas Blanket /
FR3
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 108 RTE CP 886003183 OA 3 112.5 5 13200 208/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 112 Eaton Unit Substation 13JC660140001 KNAN 3 500 5 13200 480/277
Gas Blanket /
FR3
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 119 ABB 114JC703090001 KNAN 3 225 5 13200 208/120
Gas Blanket /
Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 146 Square D Distribution
30141278-002-
01 3 225 5 13200 208/120
Gas Blanket /
FR3
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XF 1301
Cooper Power
Systems 936001226 OA 3 113 5 13200 208/120
Gas Blanket /
Mineral Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers Crash Lab 2 Pioneer Transformers G10161-1 OA 3 750 5 13200 480/277
Gas Blanket /
Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers XFK Vantran CP 88V2549 OA 1 37.5 5 13200 120/120
Gas Blanket /
Oil
NLTC 2 Winding Liquid
Transformer
NORTH LOOP
FEEDS Transformers SL-1 Solomon 76497 OA? 1 37.5 5 13200 120/120 Mineral Oil
2 Page
VHAMIWSchwaL
Attachment C
17 | P a g e
TYPE
SUBSTATI
ON
EQUIPMENT
POSITION
DEVICE/
FEEDER ID
MANUF
ACTUR
ER
SYS
VOLTAGE
VOLTAGE
RATING
INSUL-
ATION
TYPE
CABLE
DATE
CIRCUIT
LENGTH
(FT)
CONDUCT
SIZE
(KCMIL)
# OF
CONDUCT
ORS
CONDUCTOR
MATERIAL
TERMINATION
LOC - LINE
TERMINATION
LOC - LOAD
Medium
Voltage Cable
North Loop
Feed Cables
(1 ) BLDG 115 to
HVS -A Uniblend 1 Copper Medium
Voltage Cable
North Loop
Feed Cables
(2) HVS-A to
HVP-K Source A
Cable
CM 13,200 15,000 1998 725 250 1 Copper HVS-A Source A HVP-K Source A
Medium
Voltage Cable
North Loop
Feed Cables
(3) HVS-A to
HVP-K Source B
Cable
CM 13,200 15,000 1998 725 250 1 Copper HVS-A Source B HVP-K Source B
Medium
Voltage Cable
North Loop
Feed Cables
(4) HVP-K to
HVP-2 Source A
Cable
CM 13,200 15,000 1998 528 250 1 Copper HVP-K Source A HVP-2 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(5) HVP-K to
HVP-2 Source B
Cable
CM 13,200 15,000 1998 528 250 1 Copper HVP-K Source B HVP-2 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(6) HVP-2 to HVP-
3 Source A Uniblend 13,200 15,000 MV-90 1988 332 250 1 Copper HVP-2 Source A HVP-3 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(7) HVP-2 to HVP-
3 Source B Uniblend 13,200 15,000 MV-90 1988 332 250 1 Copper HVP-2 Source B HVP-3 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(8) HVP-3 to HVP-
4 Source A Uniblend 13,200 15,000 MV-90 1988 350 250 1 Copper HVP-3 Source A HVP-4 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(9) HVP-3 to HVP-
4 Source B Uniblend 13,200 15,000 MV-90 1988 350 250 1 Copper HVP-3 Source B HVP-4 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(10) HVP-4 to
HVS-4 Source A Uniblend 13,200 15,000 EPR 1988 25 250 1 Copper HVP-4 Source A HVS-4 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(11) HVP-4 to
HVS-4 Source B Uniblend 13,200 15,000 EPR 1988 25 250 1 Copper HVP-4 Source B HVS-4 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(12) HVP-4 to
HVP-8 Source A Uniblend 13,200 15,000 EPR 1988 480 250 1 Copper HVP-4 Source A HVP-4 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(13) HVP-4 to
HVP-8 Source B Prysiam 13,200 15,000 XEPR 2013 480 250 1 Copper HVP-4 Source B HVP-8 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(14) HVP-8 to XF-
41 Source A Uniblend 13,200 15,000 EPR 1988 30 250 1 Copper HVP-8 Source A XF-41 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(15) HVP-8 to XF-
41 Source B Uniblend 13,200 15,000 EPR 1988 30 250 1 Copper HVP-8 Source B XF-41 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(16) HVP-8 to
HVP-11 Source A Uniblend 13,200 15,000 EPR 1988 822 250 1 Copper HVP-8 Source A HVP-11 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(17) HVP-8 to
HVP-11 Source B Uniblend 13,200 15,000 EPR 1988 822 250 1 Copper HVP-8 Source B HVP-11 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(18) HVP-11 to
HVS-11 Source A Uniblend 13,200 15,000 EPR 1988 25 250 1 Copper HVP-11 Source A HVA-11 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(19) HVP-11 to
HVS-11 Source B Uniblend 13,200 15,000 EPR 1988 25 250 1 Copper HVP-11 Source B HVA-11 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(20) HVP-11 to
XF-37 Uniblend Copper Medium
Voltage Cable
North Loop
Feed Cables
(21) HVP-3 to
HVP-15 Source A Uniblend 13,800 15,000 EPR 1988 352 250 1 Copper HVP-3 Source A HVP-15 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(22) HVP-3 to
HVP-15 Source B Uniblend 13,800 15,000 EPR 1988 352 250 1 Copper HVP-3 Source B HVP-15 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(23) HVP-15 to
HVP-16 Source B Uniblend 13,200 15,000 EPR 1988 226 250 1 Copper HVP-15 Source B HVP-16 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(24) HVP-15 to
HVP-16 Source A Uniblend 13,200 15,000 EPR 1988 226 250 1 Copper HVP-15 Source A HVP-16 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(25) HVP-16 to
HVS-16 Source B Uniblend 13,200 1 EPR 1988 25 250 1 Copper HVP-16 Source B HVS-16 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(26) HVP-16 to
HVS-16 Source A Uniblend 13,200 1 EPR 1988 25 250 1 Copper HVP-16 Source A HVS-16 Source A
VHAMIWSchwaL Text Box 3 Page
VHAMIWSchwaL
18 | P a g e
ON
EQUIPMENT
POSITION
DEVICE/
FEEDER ID
MANUF
ACTUR
ER
SYS
VOLTAGE
VOLTAGE
RATING
INSUL-
ATION
TYPE
CABLE
DATE
CIRCUIT
LENGTH
(FT)
CONDUCT
SIZE
(KCMIL)
# OF
CONDUCT
ORS
CONDUCTOR
MATERIAL
TERMINATION
LOC - LINE
TERMINATION
LOC - LOAD
Medium
Voltage Cable
North Loop
Feed Cables
(27) HVS-16 to
XF-119 Uniblend 13,200 15,000 EPR 1988 32 250 1 Copper HVS-16 XF-119
Medium
Voltage Cable
North Loop
Feed Cables
(28) hvs-16 TO xf-
40 Uniblend Copper Medium
Voltage Cable
North Loop
Feed Cables
(29) HVP-15 to
HVP-18 Source A Uniblend 13,800 15,000 MV-90 1988 242 250 1 Copper HVP-18 Source A HVP-15 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(30) HVP-15 to
HVP-18 Source B Uniblend 13,800 15,000 MV-90 1988 242 250 1 Copper HVP-18 Source B HVP-15 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(31) HVP-18 to
HVS-18 Source A Uniblend 13,800 15,000 MV-90 1987 25 250 1 Copper HVP-18 Source A HVS-18 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(32) HVP-18 to
HVS-18 Source B Uniblend 13,800 15,000 MV-90 1987 25 250 1 Copper HVP-18 Source B HVS-18 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(33) HVP-18 to
XF-49 Source A Uniblend 13,800 15,000 MV-90 1988 140 250 1 Copper HVP-18 Source A XF-49 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(34) HVP-15 to
HVP-20 Source A Uniblend 13,200 15,000 EPR 1988 350 250 1 Copper HVP-15 Source A HVP-20 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(35) HVP-15 to
HVP-20 Source B Uniblend 13,200 15,000 EPR 1988 350 250 1 Copper HVP-15 Source B HVP-20 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(36) HVP-20 to
HVS-20 Source B Uniblend 13,200 15,000 MV-90 1988 0 250 1 Copper HVP-20 Source B HVS-20 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(37) HVP-20 to
HVS-20 Source A Uniblend 13,200 15,000 MV-90 1988 25 250 1 Copper HVP-20 Source A HVS-20 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(38) HVS-20 to
XF-102 Uniblend 13,200 15,000 EPR 1988 185 250 1 Copper HVS-20 XF-102
Medium
Voltage Cable
North Loop
Feed Cables
(39) HVP-22 to
HVP-20 Source B Uniblend 13,200 15,000 MV-90 1988 141 250 1 Copper HVP-22 Source B HVP-20 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(40) HVP-22 to
HVP-20 Source A Uniblend 13,200 15,000 MV-90 1988 141 250 1 Copper HVP-22 Source A HVP-20 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(41) HVP-22 to
HVP-23 Source B Uniblend 13,200 15,000 MV-90 1988 215 250 1 Copper HVP-22 Source B HVP-23 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(42) HVP-22 to
HVP-23 Source A Uniblend 13,200 15,000 MV-90 1988 215 250 1 Copper HVP-22 Source A HVP-23 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(43) HVP-23 to
HVP-24 Source A Uniblend 13,200 15,000 MV-90 1988 250 1 Copper HVP-23 Source A HVP-24 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(44) HVP-23 to
HVP-24 Source B Uniblend 13,200 15,000 MV-90 1988 255 250 1 Copper HVP-23 Source B HVP-24 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(45) HVP-40 to
HVP-24 Source B Uniblend 13,200 15,000 EPR 1988 735 250 1 Copper HVP-24 Source A HVP-40 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(46) HVS-18 to
XF-112 Uniblend 13,800 15,000 MV-90 1988 188 250 1 Copper HVP-18 XF-112
Medium
Voltage Cable
North Loop
Feed Cables
(47) HVP-40 to
HVP-41 Source A Uniblend 13,200 15,000 EPR 1988 265 250 1 Copper HVP-40 Source A HVP-41 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(48) HVS-41 to
XF-12 Source A Uniblend 13,200 15,000 EPR 1988 107 250 1 Copper HVS-41 Source A XF-12 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(49) HVP-41 to
XF-16 Source A Uniblend 13,200 15,000 EPR 1988 157 250 1 Copper HVP-41 Source A XF-16 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(50) HVP-41 to
HVP-42 Source A Uniblend 13,200 15,000 EPR 1988 215 250 1 Copper HVP-41 Source A HVP-42 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(51) HVP-42 to
XF-17 Source A Uniblend 13,200 15,000 EPR 1988 189 250 1 Copper HVP-42 Source A XF-17
Medium
Voltage Cable
North Loop
Feed Cables
(52) HVP-42 to
HVP-44 Source A Uniblend 13,200 15,000 EPR 1988 426 250 1 Copper HVP-42 Source A HVP-44 Source A
VHAMIWSchwaL Text Box 4 Page
VHAMIWSchwaL
19 | P a g e
ON
EQUIPMENT
POSITION
DEVICE/
FEEDER ID
MANUF
ACTUR
ER
SYS
VOLTAGE
VOLTAGE
RATING
INSUL-
ATION
TYPE
CABLE
DATE
CIRCUIT
LENGTH
(FT)
CONDUCT
SIZE
(KCMIL)
# OF
CONDUCT
ORS
CONDUCTOR
MATERIAL
TERMINATION
LOC - LINE
TERMINATION
LOC - LOAD
Medium
Voltage Cable
North Loop
Feed Cables
(53) HVP-44 to
XF-19 Uniblend 13,200 15,000 EPR 1988 31 250 1 Copper HVP-44 Source A XF-19
Medium
Voltage Cable
North Loop
Feed Cables
(54) HVP-44 to
XF-62 Source A Uniblend 13,200 15,000 EPR 1988 202 250 1 Copper HVP-44 Source A XF-62
Medium
Voltage Cable
North Loop
Feed Cables
(55) HVP-27 to
HVP-24 Source A Uniblend 13,200 15,000 EPR 1988 650 250 1 Copper HVP-27 Source A HVP-24 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(56) HVP-27 to
HVP-24 Source B Uniblend 13,200 15,000 EPR 1988 650 250 1 Copper HVP-27 Source B HVP-24 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(57) HVP-27 to
XF-6 Source A Uniblend 13,200 15,000 EPR 1988 198 250 1 Copper HVP-27 Source A XF-6 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(58) HVP-27 to
XF-6 Source B Uniblend 13,200 15,000 EPR 1988 198 250 1 Copper HVP-27 Source B XF-6 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(59) HVP-27 to
HVP-29 Source A Uniblend 13,200 15,000 EPR 1988 204 250 1 Copper HVP-27 Source A HVP-29 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(60) HVP-27 to
HVP-29 Source B Uniblend 13,200 15,000 EPR 1988 204 250 1 Copper HVP-27 Source B HVP-29 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(61) HVP-29 to
HVP-30 Source B Uniblend 13,200 15,000 EPR 1988 363 250 1 Copper HVP-29 Source B HVP-30 Source B
Medium
Voltahe Cable
North Loop
Feed Cables
(62) HVP-29 to
HVP-30 Source A Uniblend 13,200 15,000 EPR 1988 363 250 1 Copper HVP-29 Source A HVP-30 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(63) HVP-30 to
XF-11 Source A Uniblend 13,200 15,000 EPR 1988 30 250 1 Copper HVP-30 Source A XF-11
Medium
Voltage Cable
North Loop
Feed Cables
(64) HVP-30 to
XF-7 Source A Uniblend 13,200 15,000 EPR 1988 87 250 1 Copper HVP-30 Source A XF-7 Source A
Medium
Voltahe Cable
North Loop
Feed Cables
(65) HVP-30 to
XF-7 Source B Uniblend 13,200 15,000 EPR 1988 87 250 1 Copper HVP-30 Source B XF-7 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(66) HVP-29 to
XF-5 Source A Uniblend 13,200 15,000 EPR 1988 30 250 1 Copper HVP-29 Source A XF-5 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(67) HVP-29 to
XF-5 Source B Uniblend 13,200 15,000 EPR 1988 30 250 1 Copper HVP-29 Source B XF-5 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(68) HVP-29 to
HVP-31 Source A Uniblend 13,200 15,000 EPR 1988 387 250 1 Copper HVP-29 Source A HVP-31 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(69) HVP-29 to
HVP-31 Source B Uniblend 13,200 15,000 EPR 1988 387 250 1 Copper HVP-29 Source B HVP-31 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(70) HVP-31 to
XF-3 Source A Uniblend 13,200 15,000 EPR 1988 184 250 1 Copper HVP-31 Source A XF-3 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(71) HVP-31 to
XF-3 Source B Uniblend 13,200 15,000 EPR 1988 184 250 1 Copper HVP-31 Source B XF-3 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(72) HVP-31 to
TX-2 Source A Uniblend 13,200 15,000 EPR 1988 225 250 1 Copper HVP-31 Source A TX-2 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(73) HVP-31 to
TX-2 Source B Uniblend 13,200 15,000 EPR 1988 225 250 1 Copper HVP-31 Source B XF-2 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(74) HVP-31 to
HVP-34 Source A Uniblend 13,200 15,000 EPR 1988 363 250 1 Copper HVP-31 Source A HVP-34 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(75) HVS-SL1 to
XF-K
Not
Visible 13,200 15 N/A
Not
Visible 0 Not Visible 1 Copper HVS-SL1 XF-K
Medium
Voltage Cable
North Loop
Feed Cables
(76) HVS-4 to XF-
43 Uniblend 13,200 15,000 EPR 1988 52 250 1 Copper HVS-41 Source A XF-43
Medium
Voltage Cable
North Loop
Feed Cables
(77) HVP-34 to
XF-1 Source A Uniblend 13,200 15,000 EPR 1988 31 250 1 Copper HVP-34 Source A XF-1
Medium
Voltage Cable
North Loop
Feed Cables
(78) HVP-34 to
HVP-36 Source A Uniblend 13,200 15,000 EPR 1988 504 250 1 Copper HVP-34 Source A HVP-36 Source A
VHAMIWSchwaL Text Box 5 Page
VHAMIWSchwaL
20 | P a g e
ON
EQUIPMENT
POSITION
DEVICE/
FEEDER ID
MANUF
ACTUR
ER
SYS
VOLTAGE
VOLTAGE
RATING
INSUL-
ATION
TYPE
CABLE
DATE
CIRCUIT
LENGTH
(FT)
CONDUCT
SIZE
(KCMIL)
# OF
CONDUCT
ORS
CONDUCTOR
MATERIAL
TERMINATION
LOC - LINE
TERMINATION
LOC - LOAD
Medium
Voltage Cable
North Loop
Feed Cables
(79) HVP-36 to
XF-20 Source A Uniblend 13,200 15,000 EPR 1988 32 250 1 Copper HVP-36 Source A XF-20
Medium
Voltage Cable
North Loop
Feed Cables
(80) HVS-36 to
XF-97 Source A Uniblend 13,200 15,000 EPR 1988 225 250 1 Copper HVS-36 Source A XF-97 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(81) HVP-36 to
XF-108 Source A Uniblend 13,200 15,000 EPR 1988 244 250 1 Copper HVP-36 Source A XF-108
Medium
Voltage Cable
North Loop
Feed Cables
(82) HVP-40 to
XF-14 Source A Uniblend 13,200 15,000 EPR 1988 20 250 1 Copper HVP-40 Source A XF-14 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(83) HVS-11 to
XF-39 Uniblend 13,200 15,000 EPR 1988 25 250 1 Copper HVS-11 XF-39
Medium
Voltage Cable
North Loop
Feed Cables
(84) HVP-36 to
HVS-36 Source A Uniblend 13,200 15,000 EPR 1988 35 250 1 Copper HVP-36 Source A HVS-36 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(85) HVS-36 to
XF-36 Source A Uniblend 13,200 15,000 EPR 1988 0 250 1 Copper HVS-36 Source A XF-36
Medium
Voltage Cable
North Loop
Feed Cables
(86) HVP-41 to
HVS-41 Source A Uniblend 13,200 15,000 EPR 1988 30 250 1 Copper HVP-41 Source A HVS-41 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(87) HVS-41 to
XF-41 Source A Uniblend 13,200 15,000 EPR 1988 30 250 1 Copper HVS-41 Source A XF-41 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(88) HVP-2 to
HVS-2 Source A Uniblend 13,200 15 MV-90 1990 0 250 1 Copper HVP-2 Source A HVS-2 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(89) HVP-2 to
HVS-2 Source B Uniblend 13,200 15 MV-90 1990 0 250 1 Copper HVP-2 Source B HVS-2 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(90) HVP-K to
HVS-SL1 Source A
Rome
Cable 13,200 15 N/A ? 0 250 1 Copper HVP-K Source A HVS-LS1 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(91) HVP-K to
HVS-SL1 Source B
Rome
Cable 13,200 15 N/A ? 0 250 1 Copper HVP-K Source B HVS-SL1 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(92) HVS-SL1 to
XF-SL1
Not
Visible 13,200 15 N/A ? 0 ? 1 Copper HVS-SL1 XF-SL1
Medium
Voltage Cable
North Loop
Feed Cables
(93) HVS-2 to XF-
1301 Uniblend 13,200 15 MV-90 1988 0 250 1 Copper HVS-2 XF-1301
Medium
Voltage Cable
North Loop
Feed Cables
(94) HVP-22 to
HVS-22 Source A Pirella 13,200 15,000 MV-105 1998 0 250 1 Copper HVP-22 Source A HVS-22 Source A
Medium
Voltage Cable
North Loop
Feed Cables
(95) HVP-22 to
HVS-22 Source B Pirella 13,200 15,000 MV-105 1998 0 250 1 Copper HVP-22 Source B HVS-22 Source B
Medium
Voltage Cable
North Loop
Feed Cables
(96) HVS-22 to
CL1 Xfmer Pirella 13,200 15,000 MV-120 1998 0 250 1 Copper HVS-22 CL1 Xfmer
Medium
Voltage Cable
North Loop
Feed Cables
(97) HVP-27 to
XF-27 Uniblend 13,200 15,000 EPR 1987 20 250 1 Copper HVP-27 XF-27
Medium
Voltage Cable
North Loop
Feed Cables
(98) HVP-8 to
HVS-146 Uniblend 13,200 15,000 EPR 2013 1200 1/0 AWG 1 Copper HVP-8 HVS-146
Medium
Voltage Cable
North Loop
Feed Cables
(99) HVS-146 to
XF-146 Uniblend 13,200 15,000 EPR 2013 30 1/0 AWG 1 Copper HVS-146 XF-146
Medium
Voltage Cable
North Loop
Feed
HVP-15 to HVP-3
Source A
(22) HVP-3 to
HVP-15 Source B Uniblend 13,800 15,000 EPR 1988 352 250 1 Copper HVP-3 Source B HVP-15 Source B
6 Page
VHAMIWSchwaL
21 | P a g e
TYPE SUBSTATION
POSITION
DEVICE/
FEEDER
ID
MANUFACTURER TYPE
MODEL/STYLE
SYS
VOLTAGE
VOLTAGE
RATING
CURRENT
RATING
BIL
(KV)
Medium Voltage Switch North Loop Feeds Switches HVS-2 A Cooper - Kyle N/A R-Vac 10 13,800 15,000 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-2 B Cooper - Kyle N/A R-Vac 10 13,800 15,000 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-4 A RTE N/A Most 10 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-4 B RTE N/A Most 10 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-11 A RTE N/A Most 10 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-11 B RTE N/A Most 10 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-16 A RTE N/A Most 10 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-16 B RTE N/A Most 10 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-18 A RTE N/A Most 10 13,800 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-18 B RTE N/A Most 10 13,800 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-20 A RTE N/A Most 10 13,800 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-20 B RTE N/A Most 10 13,800 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-36 A S&C Electric N/A N/A 13,800 14,400 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-36 B S&C Electric N/A N/A 13,800 14,400 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-41 A S&C Electric N/A PMH-6 15,500 600
Medium Voltage Switch North Loop Feeds Switches HVS-41 B S&C Electric N/A PMH-6 15,500 600
Medium Voltage Switch North Loop Feeds Switches HVA-112 Eaton MVS 2 1D780050G32 13,800 15,000 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVA-146 Square D HVL N/A 13,800 15,000 1200 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-A (A) RTE N/A Most 10 13,800 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches HVS-A (B) RTE N/A Most 10 13,800 15,500 600 95,000
Medium Voltage Switch North Loop Feeds Switches
HVS-CLA
(A) Scott Engineering N/A 160125-0 13,800 13,800 200 95,000
Medium Voltage Switch North Loop Feeds Switches
HVS-CL1
(B) Scott Engineering N/A 160125-0 13,800 13,800 200 95,000
Medium Voltage Switch North Loop Feeds Switches
HVS-SL1
A Federal Pacific / FPE N/A N/A 14,400 17,000 200 95,000
Medium Voltage Switch North Loop Feeds Switches
HVS-SL1
B Federal Pacific / FPE N/A N/A 14,400 17,000 200 95
Bldg 113 (Below) reference Manuf. MODEL # TRIP voltage
M2B 3200A Eaton MDS362 3200A 480
F3B 1600A Eaton MDN616 800A 480
F4B 1600A , MDN616 Eaton MDN616 1600A 480
F5B 1600A Eaton MDN616 400A 480
F3C 1600A Eaton MDN616 800A 480
F4C 1600A Eaton MDN616 600A 480
Text Box 7 Page
VHAMIWSchwaL
22 | P a g e
F5C 1600A Eaton MDN616 400A 480
F3D 2000A Eaton MDN620 1600A 480
F4D 1600A Eaton MDN616 200A 480
East transformer Eaton Ser# 1359002223 13.2k/480
WEST SWITCHBOARD
BREAKERS
M4B 3200A Eaton MDN632 3200A 480
F1B 1600A Eaton MDN616 800A 480
F2B 1600A Eaton MDN616 400A 480
F1C 1600A Eaton MDN616 400A 480
F2C 1600A Eaton MDN616 400A 480
F3C 1600A Eaton MDN616 1600A 480
F1D 2000A Eaton MDN620 2000A 480
F2D 1600A Eaton MDN616 400A 480
West transformer
Cooper
Power Ser# 1359002211 13.2k/480
Blsg 147 – 148 bldg. type manuf. devise mod/style ser# voltage AMP
146 switch SQ-D HVP-146 15-E1
146 transfrmr SQ-D HVP-146 XF-147 225kva 13.2K-208/120 Y
146 cables HVS146-XFMR146 3-#2/1-#2 MV-105 600V grd
146 cables HVP146-HVP147 3-#1/1-#1 MV-105 15kv
146 cables XFMR146-CB-600-146 (2)4-#350/1#2 Sq-D, HC4259TSHR ser 1, 4 wire 600a panel 400A
146 breaker SQ-D CB-600-146/DL-146 LDA36400U31X
147 switch SQ-D HVP-147 15-E1
147 transfrmr SQ-D HVP-147 XF-147 225kva 13.2K-208/120 Y
147 cables HVS147-XFMR147 3-#2/1-#2 MV-105 600V grd
VHAMIWSchwaL Text Box 8 Page
VHAMIWSchwaL
23 | P a g e
147 cables HVP147-HVP148 3-#1/1-#1 MV-105 15kv
147 cables XFMR147-CB-600-147 (2)4-#350/1#2 Sq-D, HC4259TSHR ser 1, 4 wire 600a panel 400A
147 breaker SQ-D CB-600-147/ DL-147 LDA36400U31X
148 switch SQ-D HVP-148 15-E1
148 transfrmr SQ-D HVP-148 XF-147 225kva 13.2K-208/120 Y
148 cables HVS148-XFMR148 3-#2/1#2 MV-105 600V grd
148 cables XFMR148-CB-600-148 (2)4-#350/1#2 Sq-D, HC4259TSHR ser 1, 4 wire 600a panel 400A
148 breaker SQ-D CB-600-148/DL-148 LDA36400U31X
Bldg 112
DH-SB-BLDG112-1 (PANEL TYPE: PRL4B, CAT#6572C66G11, 3PHASE/4WIRE 600A 480/277)
I. MAIN BREAKER
L630H CAT#LGH363ONN
STYLE:69D4632G03 600 A
POLES:3
II. BREAKER (FEEDS TO EDH-SB-BLD112-2 VIA ATS) ALL SETTINGS=10
HKD65K CAT# HKD3400F
STYLE: 1492D82G03 400 AMP
POLES: 3
ATS:
III. ATS-SB-BLD112-1
Zenith ZTE
MDP:
I. EDH-SB-BLDG-1 (PANEL TYPE: PRL4B, CAT#6572C66G11 3PH4W 400A)
A. GENERATOR BREAKER (HKD 65K, CAT# HKD3400F, STYLE 1492D82G03, 400A, (SETTINGS @ 10)
B. LOAD BANK DISCO BREAKER (65K, CAT# HKD3400F, STYLE 1492D82G03, 400A, (SETTINGS @ 10)
II. EDH-SB-BLDG-2 (PANEL TYPE: PRL4B, CAT#6572C66G11 3PH4W 400A)
A. MAIN BREAKER (65K, CAT# HKD3400F, STYLE 1492D82G03, 400A, (SETTINGS @ 10)
B. ELH-SB-BLD112-1 (100A BREAKER)
Panels:
I. ELH-SB-BLD112-1 (fed from EDH-SB-BLD112-2)
Eaton Prl3A Panel Amps: 100
480/277 3Phase 4Wire
CAT#: 8804C08G02
Job # LMK0009720-010I
II. EPL-SB-BLD112-1 (fed from ELH-SB-BLD112-1)
Eaton Prl1A Panel Amps: 100
208/120V 3Phase 4Wire
CAT#: LMK0009720-010I
End of Option Year Two
VHAMIWSchwaL Text Box 9 Page
VHAMIWSchwaL
File details come from the government source that posted it. Updated .