ATTACHMENT C - FFE.pdf

PDF 24 MB Posted

Attached to
B115 Life Extension Center- Lean-to Construction
Solicitation number
6046458
Issued by

About this file

This document is an attachment titled "ATTACHMENT C - FFE.pdf" related to the federal contract opportunity "B115 Life Extension Center- Lean-to Construction" with Solicitation Number 6046458.

The solicitation is reserved exclusively for vendors of the Blue Small Business MACC (Multiple Award Construction Contract) managed by NAVFAC Washington. The scope of work includes providing labor, materials, equipment, and supervision to repair and renovate the interior of a lean-to facility, including replacing the fire protection systems and under-slab sanitary sewer lines. The facility requires an explosive safety room on the first floor and secure spaces with intrusion detection systems on the second floor. The roof hatch also needs to be relocated and replaced. This is a design-build requirement.

View the file

Other files

File Type Posted
Solicitation N40080-18-R-0002 X025..pdf PDF
ATTACHMENT D - CATEX.pdf PDF
ATTACHMENT F - Base Access Form B-2805.doc DOC document
ATTACHMENT E - PreBid Inquiry Form.xls XLS spreadsheet
ATTACHMENT B - Drawings.pdf PDF
ATTACHMENT A - Specifications.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COMPREHENSIVE INTERIOR DESIGN (CID) PACKAGE –

ISSUED FOR CONSTRUCTION SUBMISSION

DP1-C CENTER LEAN-TO

H115 AE HANGAR LIFE EXTENSION

NAS, PAX RIVER, MD

CONTRACT NO. N4008022D001

TASK ORDER: N4008022F5048

MAY 03, 2024

NAVFAC WASHINGTON

SUBMITTED BY:

POND - MICHAEL BAKER INTERNATIONAL JV

3500 PARKWAY LANE

SUITE 600

NORCROSS, GA 30092-2861

SUBMITTED TO:

DP1-C CENTER LEAN-TO, H115 AE HANGAR LIFE EXTENSION

COMPREHENSIVE INTERIOR DESIGN

ISSUED FOR CONSTRUCTION SUBMISSION

MAY 03, 2024

TABLE OF CONTENTS

*Items included in this binder are for color/pattern review only. Drawings and samples included are for reference only. Please refer to construction drawings for more information.

Table of Contents

1. Design Analysis – Chapter 6 – Interior Design

2. Drawings: IN-Series IN001 Interior Finish – Interior Material and Color Basis of Design and Notes IN110 Overall – Interior Finish – First Floor Plan IN111 Interior Finish – First Floor Plan – Areas A and B IN120 Overall – Interior Finish – Second Floor Plan IN121 Interior Finish – Second Floor Plan – Areas A and B IN501 Interior Finish – Details IN901 Interior Finish – Renderings

3. Drawings: IG-Series IG110 Overall – Signage – First Floor Plan IG111 Signage – First Floor Plan – Areas A and B IG210 Overall – Signage – Second Floor Plan IG211 Signage – Second Floor Plan – Areas A and B IG501 Signage – Details IG502 Signage – Details (Continued) IG503 Signage – Details (Continued) IG601 Signage – Schedules

4. Interior SID Color Boards

5. Drawings: IF-Series IF110 Overall – Interior Furniture – First Floor Plan IF111 Interior Furniture – First Floor Plan – Areas A and B IF210 Overall – Interior Furniture – Second Floor Plan IF211 Interior Furniture – Second Floor Plan – Areas A and B IF401 Interior Furniture – Enlarged Furniture Details

6. FF&E Cost Estimate

7. FF&E Basis of Design

DP1-C CENTER LEAN-TO, H115 AE HANGAR LIFE EXTENSION

COMPREHENSIVE INTERIOR DESIGN

PRE-FINAL 100% DESIGN SUBMISSION

AUGUST 31, 2023

TABLE OF CONTENTS

*Items included in this binder are for color/pattern review only. Drawings and samples included are for reference only. Please refer to construction drawings for more information.

Table of Contents (Design Build)

8. Drawings: GS002 Maintenance Control Furniture Plan and Details

9. FF&E Cost Estimate: GS-Series

H115 AE Hangar Life Extension Basis of Design NAS Pax River, MD DP1-C Center Lean To Issued for Construction Submission

T.O. N4008022F5048 CHAPTER 6 – INTERIOR DESIGN

6 -1

CHAPTER 6 – INTERIOR DESIGN

1) SCOPE SUMMARY

a) Design Package

i) Refer to Chapter 1 – GENERAL OVERVIEW

ii) The Comprehensive Interior Design (CID) package consists of an integrated palette of finishes spanning Structural Interior Design (SID) building elements and Furniture, Fixtures and Equipment (FF&E). This package includes materials selected for durability and longevity as well as aesthetics appropriate to the building’s primary functions. The Furniture, Fixtures and Equipment provides a flexible and adaptable space for the Hangar H115 Life Extension.

b) Project Objectives

i) The Design Analysis is a roadmap which outlines the required design directive and the approach used to create the Contract Drawings and Specifications.

ii) The Scope of Work provides the interior design for the Hangar H115 Life Extension located at Naval Air Station Pax River, Maryland. Interior Design includes flooring finishes, wall finishes, ceiling finishes, a comprehensive signage package, and furniture/equipment layouts.

2) REFERENCES

a) Scope of Architect-Engineer Services (SAES) dated 22 May 2022

b) Building Codes and United Facilities Criteria

i) See Chapter 5 – Architectural Design Analysis

3) CRITERIA

a) Interior Environment

i) The building interior finishes are mindfully selected to include products that are durable, low maintenance and environmentally friendly.

ii) The facility is a three-story aircraft hangar design with areas that require acoustically rated designs. This is accomplished through STC rated partitions and high NRC acoustical ceiling tiles. These spaces include the Center Lean-To, Waterside Lean-To, and Roadside Lean-To spaces. Interior materials at first floor shop areas must be durable. The upper floors are

NAS Pax River, MD DP1-C Center Lean To Issued for Construction Submission

6 -2 considered office spaces with durable materials but different use. Acoustics on the upper floor office spaces is pertinent.

iii) The building is inherently accessible and includes barrier free environments. Furniture is arranged to create clear paths in main travel areas, high traffic areas and office spaces.

Barrier free transitions are used where flooring materials change. Signage is designed in accordance with the codes, standards and references in the General Overview and Applicable Criteria Chapter. Text height and visual contrast of signage content is included in the design.

iv) Finishes are selected based on the guidance of UFC 4-211-01: Aircraft Maintenance Hangars, with Change 3.

b) Sustainable Design

i) Through the use of durable products which contain low VOC emissions and high recycled content, when possible, the interior of the Hangar H115 is designed as a healthy and comfortable space for the building occupants and guests.

ii) We consider indoor air quality as well as recycled material content when selecting materials.

Emphasis is placed on selecting furniture that meets and exceeds LEED requirements for this project.

4) DESIGN APPROACH - Interior Finishes

a) Aesthetics

i) Material finishes are selected to provide a neutral base palette with timeless accents that will enrich the spaces. The DOR, along with NAVFAC and the Activity develops an integrated interior/exterior appearance and implement this finish selections throughout the design process.

b) Restrooms

i) Restrooms include floor mounted, overhead-braced, solid plastic HDPE toilet and urinal partitions in a complimentary color to the wall and floor tile in addition to the solid surface counter with integral sinks.

c) Floors

i) Floor finishes are selected for durability and ease of maintenance.

ii) Surface walk-off mat with 100% solution dyed carpet insert are provided at building entrances.

iii) First floor spaces, not listed below, are considered heavy maintenance and floors are a reflective, light-colored, 3-coat fuel resistive resinous flooring system. Floor coating color is

NAS Pax River, MD DP1-C Center Lean To Issued for Construction Submission

6 -3 light gray to reflect and contrast sharply with foreign objects, small parts and will enhance visibility of such items.

iv) Comm Rooms have vinyl tile (SDT).

v) Janitor and Restroom floors are rectified, through-body porcelain tile with epoxy grout.

Stainless-steel transitions are between floor and wall. Marble threshold at room entry.

vi) On upper levels, carpet tile is used in office and admin areas as well as conference rooms.

vii) On upper levels, resilient flooring is used in break areas and corridors with break areas.

d) Window Treatments

i) Windows receive manually operated, single roller sunscreen and room darkening shades at exterior windows. Shades are mounted within the window recesses.

ii) Window stools are a solid surface material.

e) Doors

i) See Chapter 5 – Architectural Design Analysis.

ii) Door finishes include, but are not limited to, wood veneer and hollow metal.

f) Interior Walls

i) Restroom walls have porcelain tile to the finished ceiling with stainless steel edge protection at inside and outside corners. Porcelain cove base is applied as wall base in restrooms.

ii) Walls are painted with a high performance, low VOC paint as indicated in drawings.

iii) Conference Room walls receive markerboards two sides of the rooms.

iv) Exposed corners receive protective corner guards where indicated on drawings.

v) Stainless-steel wall panel at mop sinks in janitor closets on wet walls.

vi) Continuous roll rubber cove base is provided in rooms as indicated in drawings.

g) Interior Ceilings

i) Ceiling finishes primarily consist of high NRC acoustical ceiling panels and GWB ceiling painted with low VOC paint.

ii) Restrooms receive epoxy, moisture resistant, low VOC paint.

iii) Painted exposed structure as indicated on drawings.

NAS Pax River, MD DP1-C Center Lean To Issued for Construction Submission

6 -4

h) Casework Finishes

i) Restroom vanities receive solid surface counter with integral solid surface sink and removable, accessible laminate panel to conceal plumbing.

ii) Mother’s room (Roadside phase) has laminate base cabinets with an undercounter refrigerator, stainless bar-sized undermount sink and solid surface countertop.

iii) Break room has laminate base cabinets with a stainless undermount sink and quartz countertop. Appliances include a counter microwave, coffeemaker and a full-sized refrigerator.

i) Signage and Wayfinding

i) Comprehensive signage and wayfinding system is incorporated into the project; signage including directional, room identification and notification messages are in accordance with the UFC 3-120-01 Sign Standards and NAVFAC guidelines.

j) Accessibility

i) The building is designed to incorporate accessible interiors throughout including the use of wheeled traffic flooring transitions for a barrier free environment.

5) DESIGN APPROACH – Furniture and Equipment

a) Aesthetics

i) The DOR develops furniture selections and space layouts efficiently using floor space, providing flexible environments for different group functions, and maximizing the number of seats. Furniture selections are aesthetically driven by the Structural Interior Design and user feedback for a pleasant and well-coordinated interior environment.

ii) DOR contact information: Sarah Koontz, NCIDQ, LEED AP ID+C | Senior Interior Designer Sarah.Koontz@mbakerintl.com

b) Furniture

i) Rooms are furnished per the in-depth interviews with the Activity / Users. Ongoing coordination will continue as the project progresses.

ii) The FF&E selection, design and procurement is not included in the project scope.

iii) Markerboards are provided as part of the FF&E Contract.

NAS Pax River, MD DP1-C Center Lean To Issued for Construction Submission

6 -5

c) Equipment

i) Equipment is coordinated throughout the space and includes break room equipment.

ii) Equipment Peg Boards are provided as part of the Construction Contract.

d) Artwork

i) Artwork is not included in the project scope.

6) DESIGN CHANGES FROM THE PREVIOUS SUBMISSION

N/A

7) APPENDICES

a) H115 DP1-C – CID E-Binder

End of Section

F E

C

AF E D C B

AREA C

NOT IN

SCOPE

AREA D

NOT IN

SCOPE

AREA E

NOT IN

SCOPE

AREA F

NOT IN

SCOPE

ROADSIDE

HANGAR NOT

IN SCOPE

WATERSIDE

HANGAR NOT

IN SCOPE

AREA C

NOT IN

SCOPE

AREA D

NOT IN

SCOPE

AREA E

NOT IN

SCOPE

AREA F

NOT IN

SCOPE

ROADSIDE

HANGAR NOT

IN SCOPE

WATERSIDE

HANGAR NOT

IN SCOPE

C116

SUPPORT

EQUIPMENT

/HAZMAT

C115

CENTRAL

TECHNICAL

PUBLICATIONS

LIBRARYC114A

EXIT

C114

STAIR

C113

QUALITY

ASSURANCE

C111

ELECTRICAL

ROOM

C112

ELECTRICAL

ROOM

C111A

ELECTRICAL

ROOM

C110

BOEING

OFFICE

C109

SECURITY

OFFICE

C108

PASSAGE

C107A

STORAGE

C106A

OFFICE

C107

LOGS

AND

RECORDS

C106

MAINTENANCE

CONTROL

C105

CHANGE

MANAGEMENT

OFFICE

C104

PR SHOP

PILOT

EQUIPMENT

C104A

STORAGE

C104B

LAUNDRY

C102

MECHANICAL

ROOM

C103

FIRE

RISER

ROOM

C101

STAIR

AREA A

AREA B

AREA A

AREA B

A R

E A

A A

R E

A B

A R

E A

A A

R E

A B

A 1/

IN

A1/

IN

A3/ IN111

A1/ IN111

A3/

IN

A 1/

IN

A 3/

IN

A 3/

IN

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

GRAPHIC SCALE / NORTH ARROW

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IN110

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

O V

E R

A

LL

IN

TE

R

IO

R

F

IN

IS

H

F

IR

S

T F

LO

O

R P

LA

N

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149068

SCALE: 1" = 20'-0"

A1

OVERALL - INTERIOR FINISH - FIRST FLOOR PLAN

SCALE:

10' - 0" 20' - 0" 40' - 0"

1" = 20' - 0"

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P R

D C

C116

SUPPORT

EQUIPMENT

/HAZMAT

C115

CENTRAL

TECHNICAL

PUBLICATIONS

LIBRARYC114A

EXIT

C114

STAIR

C113

QUALITY

ASSURANCE

C111

ELECTRICAL

ROOM

C112

ELECTRICAL

ROOM

C111A

ELECTRICAL

ROOM

C110

BOEING

OFFICE

C109

SECURITY

OFFICE

C108

PASSAGE

C107A

STORAGE

C106A

OFFICE

C107

LOGS

AND

RECORDS

MATCHLINEMATCHLINE

A3/ IN111A3/ IN111

P2 P2

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

D C

C106

MAINTENANCE

CONTROL

C105

CHANGE

MANAGEMENT

OFFICE

C104

PR SHOP

PILOT

EQUIPMENT

C104A

STORAGE

C104B

LAUNDRY

C102

MECHANICAL

ROOM

C103

FIRE

RISER

ROOM

C101

STAIR

A1/ IN111

MATCHLINEMATCHLINE

A1/ IN111A1/ IN111

C104

PR SHOP

PILOT

EQUIPMENT

P2 P2

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

LEGEND - INTERIOR FINISH (TAG)

WALL FINISH TAGP#

OPEN AREA FLOOR TRANSITION LOCATION.

REFER TO INTERIOR FINISH SCHEDULE FOR

DOORWAY TRANSITIONS BETWEEN ROOMS.

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

KEYPLAN

GRAPHIC SCALE / NORTH ARROW

W A

S H

IN

G

T O

N D

C

B

A

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IN111

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

IN

T

E R

IO

R

F

IN

IS

H

F

IR

S

T F

LO

O

R P

LA

N

A

R E

A S

A A

N D

B

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149069

SCALE: 1/8" = 1'-0"

A1

INTERIOR FINISH - FIRST FLOOR PLAN - AREA A 0

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/8" = 1' - 0"

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/8" = 1' - 0"

SCALE: 1/8" = 1'-0"

A3

INTERIOR FINISH - FIRST FLOOR PLAN - AREA B

LEGEND - FINISH

ABBRV DESCRIPTION

ACP ACOUSTICAL - CEILING PANEL (GRID LAY)

C CONCRETE

CG CORNER GUARD

CPT CARPET

EM ENTRANCE MAT

GR GROUT

LVT LUXURY VINYL TILE

P PAINT

PC PRIVACY CURTAIN

PL PLASTIC LAMINATE

PT PORCELAIN TILE

PTB PORCELAIN TILE - BASE

QZ QUARTZ

RB RUBBER - BASE

RF RUBBER FLOOR

SH1 SHOWER CURTAIN

SS SOLID SURFACE

STL STAINLESS STEEL

TP TOILET PARTITION

VT VINYL TILE - ESD

WP WALL PROTECTION

WT WINDOW TREATMENT

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

AF E D C B

AREA C

NOT IN

SCOPE

AREA D

NOT IN

SCOPE

AREA E

NOT IN

SCOPE

AREA F

NOT IN

SCOPE

ROADSIDE

HANGAR NOT

IN SCOPE

WATERSIDE

HANGAR NOT

IN SCOPE

C210

STAIR

C213

WOMEN

C212

JANITOR

C211

MEN

C208

URINALYSIS

OFFICE C214

MECHANICAL

ROOM

(ROOF

ACCESS)

C207

COMM

ROOM

C206A

OFFICE

C206

VERTEX

C206B

OFFICE

C205

CONFERENCE

ROOM

C204A

OFFICE

C204B

OFFICE

C204

MO SUITE

C204D

OFFICE

C204C

OFFICE

C203A

OFFICE

C203B

OFFICE

C203

MIL/XO

SUITE

C203C

OFFICE

C203D

OFFICE

C202B

OFFICE

C202A

OFFICE

C202

UNDETERMINED

TEAM

C201

STAIR

C202.1

PASSAGE

C209

ELECTRICAL

CLOSET

A 1/

IN

A1/

IN

A3/ IN121

A1/ IN121

A3/

IN

A 1/

IN

A 3/

IN

A 3/

IN

AREA A

AREA B

AREA A

AREA B

A R

E A

A A

R E

A B

A R

E A

A A

R E

A B

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

GRAPHIC SCALE / NORTH ARROW

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IN120

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

O V

E R

A

LL

IN

TE

R

IO

R

F

IN

IS

H

S

E C

O N

D F

LO

O

R P

LA

N

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149070

SCALE: 1" = 20'-0"

A1

OVERALL - INTERIOR FINISH - SECOND FLOOR PLAN

SCALE:

10' - 0" 20' - 0" 40' - 0"

1" = 20' - 0"

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

C210

STAIR

C212

JANITOR

C208

URINALYSIS

OFFICE

C206A

OFFICE

C207

COMM

ROOM

C206

VERTEX

C205

CONFERENCE

ROOM

C206B

OFFICE

C202.1

PASSAGE

C214

MECHANICAL

ROOM

(ROOF

ACCESS)

C209

ELECTRICAL

CLOSET

C211

MEN

C213

WOMEN

MATCHLINEMATCHLINE

A3/ IN121A3/ IN121

P

P5

P5

EQ. EQ.

1'

1'

2' - 0"

1'

2' - 0"

P2 P2

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

D C

C204A

OFFICE

C204B

OFFICE

C204C

OFFICE

C204D

OFFICE

C204

MO SUITE

C203A

OFFICE

C203B

OFFICE

C203

MIL/XO

SUITE

C203C

OFFICE

C203D

OFFICE

C202A

OFFICE

C202B

OFFICE

C202

UNDETERMINED

TEAM

C201

STAIR

MATCHLINEMATCHLINE

A1/ IN121A1/ IN121

P5

P5

P5

P2 P2

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

TYP, EXISTING AND NEW

SURFACES, FLOOR TO

CEILING, AFTER ALL

PATCHING IS COMPLETE

R 7' - 2 5/8"

LEGEND - INTERIOR FINISH (FLOOR PATTERN)

PT1

LEGEND - INTERIOR FINISH (TAG)

WALL FINISH TAGP#

OPEN AREA FLOOR TRANSITION LOCATION.

REFER TO INTERIOR FINISH SCHEDULE FOR

DOORWAY TRANSITIONS BETWEEN ROOMS.

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

KEYPLAN

GRAPHIC SCALE / NORTH ARROW

W A

S H

IN

G

T O

N D

C

B

A

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IN121

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

IN

T

E R

IO

R

F

IN

IS

H

S

E C

O N

D F

LO

O

R P

LA

N

A

R E

A S

A A

N D

B

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149071

SCALE: 1/8" = 1'-0"

A1

INTERIOR FINISH - SECOND FLOOR PLAN - AREA A

LEGEND - FINISH

ABBRV DESCRIPTION

ACP ACOUSTICAL - CEILING PANEL (GRID LAY)

C CONCRETE

CG CORNER GUARD

CPT CARPET

EM ENTRANCE MAT

GR GROUT

LVT LUXURY VINYL TILE

P PAINT

PC PRIVACY CURTAIN

PL PLASTIC LAMINATE

PT PORCELAIN TILE

PTB PORCELAIN TILE - BASE

QZ QUARTZ

RB RUBBER - BASE

RF RUBBER FLOOR

SH1 SHOWER CURTAIN

SS SOLID SURFACE

STL STAINLESS STEEL

TP TOILET PARTITION

VT VINYL TILE - ESD

WP WALL PROTECTION

WT WINDOW TREATMENT

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/8" = 1' - 0"

SCALE: 1/8" = 1'-0"

A3

INTERIOR FINISH - SECOND FLOOR PLAN - AREA B

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

FINISHED CEILING

PT3 ACCENT

TILE, STAGGER

GROUT JOINTS

WITH PT2

PT2 WALL TILE

(7 FULL TILE

COURSES)

PTB1 AS

SCHEDULED,

STAGGER

GROUT JOINTS

WITH PT2

P4 WALL

PAINT

FINISHED FLOOR

8'

/2

1/

2" 7'

8"

1'

1/ 2"

FINISHED CEILING

FINISHED FLOOR

SPECIFIED WALL BASE

PAINT AS

SCHEDULED

SCHEDULED

CORNER GUARD

8'

0"

1/ 2"

OUTSIDE CORNER TRANSITION - TILE WALLS

PORCELAIN

WALL TILE

PORCELAIN

WALL TILE

SCHLUTER JOLLY

(W/ MATCHING

CAPS/CONNECTORS

AS REQUIRED)

[OR EQUAL]

RESINOUS FLOOR TO WALL TRANSITION

MATCHING TOP CAP

WALL FINISH

RESINOUS FLOOR WITH

INTEGRAL BASE

FLOOR

W A

LL

TILE FLOOR TO TILE WALL TRANSITION

WALL

SUBSTRATE

NOTES:

1. SEE BASIS OF DESIGN AND SPECIFICATIONS FOR FURTHER FINISH INFORMATION.

SOLID SURFACE

OR QUARTZ

COUNTERTOP

SOLID SURFACE OR

QUARTZ BACKSPLASH

COUNTER TO SPLASH TRANSITION

FLEX CAULK / SILICONE AS

REQUIRED (MATCH COUNTER)

PORCELAIN

FLOOR TILE

FLOOR

W A

LL

S

U B

S T

R A

T E

PORCELAIN WALL TILE

PORCELAIN TILE BASE (FIELD CUT

UNIFORM 1/2" OFF TOP FOR FLAT

TILE-TO-TILE INSTALLATION)

ALIGN FACE OF FLOOR TILE

WITH FACE OF COVE BASE

FLEXIBLE SEALANT TO MATCH GROUT

FLEXIBLE SEALANT TO MATCH GROUT

PORCELAIN

FLOOR TILE

FLOOR

W A

LL

S

U B

S T

R A

T E

PORCELAIN TILE BASE

ALIGN FACE OF FLOOR TILE

WITH FACE OF COVE BASE

FLEXIBLE SEALANT TO MATCH GROUT

WALL PROTECTION TO TILE BASE TRANSITION

MUD IN WALL PROTECTION

BOTTOM TRIM

WALL PROTECTION AS SCHEDULED

W A

LL

S

U B

S T

R A

T E

REFER TO SPECIFIED

WALL TYPES

OR EQUAL PRODUCT

*MODIFY INSTALLATION PER MANUFACTURER INSTRUCTIONS WHERE

SCREWS CANNOT BE USED IN CMU OR RATED WALLS.

LUXURY VINYL TILE

SUBSTRATE

METAL

REDUCER

CARPET

CONCRETE

RESILIENT REDUCER

SUBSTRATE

SUBSTRATE

PORCELAIN TILE

MARBLE THRESHOLD

LUXURY VINYL TILE

LUXURY VINYL TILE

STATIC DISSIPATIVE TILE

SUBSTRATE

RESILIENT TRANSITION

LUXURY VINYL TILE

(FEATHER FLOORING

UP IF REQUIRED)

RESINOUS FLOORING

SUBSTRATE

RUBBER FLOORING /

STATIC DISSIPATIVE TILE

RESILIENT TRANSITION

LUXURY VINYL TILE

SUBSTRATE

RESILIENT TRANSITION

RUBBER FLOORING

NOTES:

1. INSTALL TRANSITION FIRST IF REQUIRED PER MANUFACTURER'S INSTRUCTIONS TO PROPOERLY WORK WITH FLOOR SYSTEMS.

2. BUTT JOINT FLOORING MATERIALS OF THE SAME THICKNESS; VERIFY MATERIAL SIZE AND THICKNESS TO DETERMINE FINAL

TRANSITION STRIP TYPE BEFORE INSTALLING FLOORING.

3. ENSURE ALL TRANSITIONS THROUGHOUT PROJECT ARE SMOOTH AND ACCESSIBLE.

NEW FLOORING

(HEIGHT VARIES)

SUBSTRATE

METAL REDUCER

EXISTING FLOORING

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IN501

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

IN

T

E R

IO

R

F

IN

IS

H

D

E

TA

IL

S

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

131490720

SCALE:

1' - 0" 2' - 0" 4' - 0"

1/2" = 1' - 0"

SCALE: 1/2" = 1'-0"

B1

TYPICAL FINISH ELEVATION -

RESTROOM WALL TILE

SCALE: 1/2" = 1'-0"

B2

TYPICAL FINISH ELEVATION -

CORNER GUARD

SCALE: NTS

FINISH DETAIL - INTERIOR CORNER TRANSITIONS

A1

SCALE: NTS

FINISH DETAIL - CORNER GUARD

B3

SCALE: NTS

FINISH DETAIL - INTERIOR TRANSITIONS

B4

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G S

Y S

T E

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IN901

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

IN

T

E R

IO

R

F

IN

IS

H

R

E N

D E

R

IN

G S

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149073

OPEN OFFICE AREA FROM CORRIDOR MIL / XO DEPARTMENT FROM CORRIDOR

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

P

NOTE: 3D VIEWS ARE TO CONVEY DESIGN INTENT ONLY.

C

AF E D C B

AREA C

NOT IN

SCOPE

AREA D

NOT IN

SCOPE

AREA E

NOT IN

SCOPE

AREA F

NOT IN

SCOPE

ROADSIDE

HANGAR NOT

IN SCOPE

WATERSIDE

HANGAR NOT

IN SCOPE

C116

SUPPORT

EQUIPMENT

/HAZMAT

C115

CENTRAL

TECHNICAL

PUBLICATIONS

LIBRARYC114A

EXIT

C114

STAIR

C113

QUALITY

ASSURANCE

C111

ELECTRICAL

ROOM

C112

ELECTRICAL

ROOM

C111A

ELECTRICAL

ROOM

C110

BOEING

OFFICE

C109

SECURITY

OFFICE

C108

PASSAGE

C107A

STORAGE

C106A

OFFICE

C107

LOGS

AND

RECORDS

C106

MAINTENANCE

CONTROL

C105

CHANGE

MANAGEMENT

OFFICE

C104

PR SHOP

PILOT

EQUIPMENT

C104A

STORAGE

C104B

LAUNDRY

C102

MECHANICAL

ROOM

C103

FIRE

RISER

ROOM

C101

STAIR

AREA A

AREA B

AREA A

AREA B

A R

E A

A A

R E

A B

A R

E A

A A

R E

A B

A 1/

IG

A1/

IG

A3/ IN111

A1/ IG111

A3/

IN

A 1/

IG

A 3/

IG

A 3/

IN

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

GRAPHIC SCALE / NORTH ARROW

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG110

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

O V

E R

A

LL

S

IG

N

A G

E

FI

R

S T

FL

O

O R

P

LA

N

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149074

SCALE: 1" = 20'-0"

A1

OVERALL - SIGNAGE - FIRST FLOOR PLAN

SCALE:

10' - 0" 20' - 0" 40' - 0"

1" = 20' - 0"

SCALE:

10' - 0" 20' - 0" 40' - 0"

1" = 20' - 0"

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

C116

SUPPORT

EQUIPMENT

/HAZMAT

C115

CENTRAL

TECHNICAL

PUBLICATIONS

LIBRARYC114A

EXIT

C114

STAIR

C113

QUALITY

ASSURANCE

C111

ELECTRICAL

ROOM

C112

ELECTRICAL

ROOM

C111A

ELECTRICAL

ROOM

C110

BOEING

OFFICE

C109

SECURITY

OFFICE

C108

PASSAGE

C107A

STORAGE

C106A

OFFICE

C107

LOGS

AND

RECORDS

MATCHLINEMATCHLINE

A3/ IG111A3/ IG111

1 - K

6 - A

14 - A 15 - A

18 - A

16 - B

17 - B

13 - J

12 - J

11 - J

10 - A9 - A

7 - M 8 - M

4 - F

2 - K

3 - G

81 - N 82 - N

83 - N 84 - N

85 - N

86 - N

87 - N

88 - N89 - N

D C

C106

MAINTENANCE

CONTROL

C105

CHANGE

MANAGEMENT

OFFICE

C104A

STORAGE

C104B

LAUNDRY

C102

MECHANICAL

ROOM

C103

FIRE

RISER

ROOM

C101

STAIR

MATCHLINEMATCHLINE

A1/ IG111A1/ IG111

C104

PR SHOP

PILOT

EQUIPMENT

19 - A

23 - B 24 - B

28 - M 29 - M

30 - M 31 - M

26 - J

25 - A22 - A

27 - J

21 - C20 - C

32 - G

90 - N91 - N

92 - N93 - N

94 - N95 - N

96 - N97 - N

98 - P

99 - O 100 - R103 - R

102 - O

101 - P

LEGEND - SIGNAGE (TAG)

SIGNAGE TAG## - XX

SIGNAGE TYPE

SIGNAGE NUMBER

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

KEYPLAN

W A

S H

IN

G

T O

N D

C

B

A

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG111

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

S

IG

N A

G E

FI

R S

T

FL

O O

R P

LA

N

A

R E

A S

A A

N D

B

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149075

SCALE: 1/8" = 1'-0"

A1

SIGNAGE - FIRST FLOOR PLAN - AREA A

LEGEND - SIGNAGE (TYPE)

TYPE DESCRIPTION QTY

A ROOM ID W/ DEPARTMENT (PRINTABLE) 25

B ROOM ID (PRINTABLE) 5

C ROOM ID (MULTIPLE LOCATIONS) 2

D TOILET - MENS 1

E TOILET - WOMENS 1

F NO SMOKING 1

G EXIT 2

H DIRECTIONAL - TYPE H 2

J ROOM ID (PERMANENT) 10

K ROOM ID (EXTERIOR) 2

L ROOM ID (W/ SLIDER) 2

M ROOM ID (STAIRS) 8

N ROOM ID (DOOR HEADER) 17

O RESTRICTIVE SIGN - TYPE O 2

P FIRE DIVISION SIGN - TYPE P 2

R FIRE SYMBOL SIGN - TYPE R 2

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/8" = 1' - 0"

SCALE: 1/8" = 1'-0"

A3

SIGNAGE - FIRST FLOOR PLAN - AREA B

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

AREA C

NOT IN

SCOPE

AREA D

NOT IN

SCOPE

AREA E

NOT IN

SCOPE

AREA F

NOT IN

SCOPE

ROADSIDE

HANGAR NOT

IN SCOPE

WATERSIDE

HANGAR NOT

IN SCOPE

C210

STAIR

C213

WOMEN

C212

JANITOR

C211

MEN

C208

URINALYSIS

OFFICE C214

MECHANICAL

ROOM

(ROOF

ACCESS)

C207

COMM

ROOM

C206A

OFFICE

C206

VERTEX

C206B

OFFICE

C205

CONFERENCE

ROOM

C204

MO SUITE

C204D

OFFICE

C204C

OFFICE

C203A

OFFICE

C203B

OFFICE

C203

MIL/XO

SUITE

C203C

OFFICE

C203D

OFFICE

C202B

OFFICE

C202A

OFFICE

C202

UNDETERMINED

TEAM

C201

STAIR

C202.1

PASSAGE

C209

ELECTRICAL

CLOSET

AREA A

AREA B

AREA A

AREA B

A R

E A

A A

R E

A B

A R

E A

A A

R E

A B

A 1/

IG

A1/

IG

A3/ IG121

A1/ IG121

A3/

IG

A 1/

IG

A 3/

IG

A 3/

IG

C204A

OFFICE

C204B

OFFICE

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

GRAPHIC SCALE / NORTH ARROW

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG120

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

O V

E R

A

LL

S

IG

N

A G

E

S E

C O

N D

F

LO

O R

P

LA

N

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149076

SCALE: 1" = 20'-0"

A1

OVERALL - SIGNAGE - SECOND FLOOR PLAN

SCALE:

10' - 0" 20' - 0" 40' - 0"

1" = 20' - 0"

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

C210

STAIR

C212

JANITOR

C208

URINALYSIS

OFFICE

C206A

OFFICE

C207

COMM

ROOM

C206

VERTEX

C205

CONFERENCE

ROOM

C206B

OFFICE

C202.1

PASSAGE

C214

MECHANICAL

ROOM

(ROOF

ACCESS)

C209

ELECTRICAL

CLOSET

C211

MEN

C213

WOMEN

MATCHLINEMATCHLINE

A3/ IG121A3/ IG121

51 - M

53 - D

54 - J

56 - J

59 - A 60 - A 61 - A

52 - J

57 - B

55 - E

58 - J

62 - J

63 - L

64 - L

79 - H

D C

C204A

OFFICE

C204B

OFFICE

C204C

OFFICE

C204D

OFFICE

C204

MO SUITE

C203A

OFFICE

C203B

OFFICE

C203

MIL/XO

SUITE

C203C

OFFICE

C203D

OFFICE

C202A

OFFICE

C202B

OFFICE

C202

UNDETERMINED

TEAM

C201

STAIR

MATCHLINEMATCHLINE

A1/ IG121A1/ IG121

66 - A 67 - A

68 - A 69 - A

71 - A 72 - A

73 - A 74 - A

76 - A 77 - A

78 - M

65 - A

70 - A

75 - A

80 - H

LEGEND - SIGNAGE (TAG)

SIGNAGE TAG## - XX

SIGNAGE TYPE

SIGNAGE NUMBER

PLAN

NORTH

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

KEYPLAN

W A

S H

IN

G

T O

N D

C

B

A

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG121

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

S

IG

N A

G E

S

E C

O N

D F

LO

O

R P

LA

N

A

R E

A S

A A

N D

B

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149077

SCALE: 1/8" = 1'-0"

A1

SIGNAGE - SECOND FLOOR PLAN - AREA A

LEGEND - SIGNAGE (TYPE)

TYPE DESCRIPTION QTY

A ROOM ID W/ DEPARTMENT (PRINTABLE) 25

B ROOM ID (PRINTABLE) 5

C ROOM ID (MULTIPLE LOCATIONS) 2

D TOILET - MENS 1

E TOILET - WOMENS 1

F NO SMOKING 1

G EXIT 2

H DIRECTIONAL - TYPE H 2

J ROOM ID (PERMANENT) 10

K ROOM ID (EXTERIOR) 2

L ROOM ID (W/ SLIDER) 2

M ROOM ID (STAIRS) 8

N ROOM ID (DOOR HEADER) 17

O RESTRICTIVE SIGN - TYPE O 2

P FIRE DIVISION SIGN - TYPE P 2

R FIRE SYMBOL SIGN - TYPE R 2

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/8" = 1' - 0"

SCALE: 1/8" = 1'-0"

A3

SIGNAGE - SECOND FLOOR PLAN - AREA B

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

SIGN SPECIFICATIONS:

SIGN SYSTEM BASIS (INTERIOR): 2/90 SIGN SYSTEMS - SLIDE, STANDARD RAIL

LARGE SIGNS AND/OR DIRECTORIES: BOX RAIL

SIGN SYSTEM BASIS (EXTERIOR): EXTERIOR CUSTOM TO MATCH KLIK DESIGN

INSERT / PANEL FINISH (INTERIOR): 708 SOFT WHITE

COPY FINISH (INTERIOR): 734 DARK GREY

PANEL FINISH (EXTERIOR): BROWN, PANTONE #7532C

COPY FINISH (EXTERIOR): 708 SOFT WHITE

COPY FINISH (REFLECTIVE): 3M SCOTCHLITE 2290 OR EQUAL APPROVED BY OWNER

COPY STYLE (STANDARD): UPPERCASE, HELVETICA REGULAR

COPY STYLE (ADA / RAISED CHARACTERS): UPPERCASE; HELVETICA LT STD REGULAR

END CAPS: SQUARE CORNER, COLOR: 734 DARK GREY

EYE WASH - PANEL FINISH AND COPY FINISH: 776 FOREST GREEN

FIRE EXTINGUISHER - PANEL FINISH AND COPY FINISH: 736 CARDINAL RED

SIGN INSERT WITH

INSERT SLOT

SIGN INSERT

REMOVAL TOOL TOP / BOTTOM

CLOSER EXTRUSION

ALUMINUM SIDE TRACK,

PROFILE AS SPECIFIED

CLIP FASTENERS

SIDE TRACK

MOUNTING CLIP

TOP / BOTTOM

CLOSER PROFILE

IMAGE BELOW SHOWS FRONT-LOADING.

SIDE-LOADING IS ALSO ACCEPTABLE

OPERATIONS

MANAGER

ATTACHMENT

FINISHED FLOOR

EXIT

4'

M

IN

. T O

B R

A

IL

LE

H

IG

H E

S T

R A

IS

E

D C

H A

R A

C T

E R

5'

M

IN

. T O

B O

T T

O M

O F

BUILDING ENTRANCE

Naval Surface

FINISHED FLOOR

Force United States Pacific Fleet

Headquarters

1' - 0"

4'

ROOM ID & EXIT

4 1/2"

DELTA

XXXX

FINISHED FLOOR

MULTI-ROOM

4 1/2"

SHOPS

OFFICES

BREAK ROOM

TRAINING

RESTROOM

LOCKERS

TIRE STORAGE↑

M

IN

IM

U

M

FINISHED FLOOR

DIRECTIONAL

XXXX####

XXXX####

XXXX####

CLEAR FLOOR SPACE

TACTILE CHARACTER

BASELINE ZONE

FINISHED CEILING FINISHED CEILING

FINISHED FLOOR

ROOM ID (DOUBLE DOOR)

FINISHED CEILING

INACTIVE

DOOR LEAF

ACTIVE

DOOR LEAF

OPERATIONS

MANAGER

ATTACHMENT

DELTA

4 1/2"

4'

M

IN

. T O

B R

A

IL

LE

H

IG

H E

S T

R A

IS

E

D C

H A

R A

C T

E R

5'

M

IN

. T O

B O

T T

O M

O F

4'

M

IN

. T O

B R

A

IL

LE

H

IG

H E

S T

R A

IS

E

D C

H A

R A

C T

E R

5'

M

IN

. T O

B O

T T

O M

O F

FINISHED CEILING

1' - 6"

1'

1' - 6"

1'

TACTILE CHARACTER

BASELINE ZONE

TACTILE CHARACTER

BASELINE ZONE

MOUNTING NOTES:

1. MOUNTING OPTIONS VARY PER SIGN TYPE. MOUNT INTERIOR AND EXTERIOR SIGNS USING CONCEALED MECHANICAL FASTENERS, FOLLOW MANUFACTURER'S RECOMMENDATIONS.

2. WHERE THERE IS LESS THAN 18" CLEAR SPACE ON THE LATCH SIDE OF A SINGLE DOOR, OR ON THE RIGHT SIDE OF DOUBLE DOORS, SIGNS WILL BE LOCATED ON THE NEAREST ADJACENT WALL. UNLESS OTHERWISE NOTED.

3. TEXT SHOWN ON SIGN DETAILS ARE EXAMPLES AND ARE NOT INTENDED FOR DESIGN PURPOSES.

EQUAL 8 1/2" EQUAL

EQUAL 8 1/2" EQUAL

REFER TO SIGNAGE PLAN FOR

DOOR HEADER SIGN LOCATIONS

MOUNTING PAN

NON-CORROSIVE COUNTERSUNK

SCREW (MINIMUM 2 AT TOP AND

BOTTOM)

ANCHOR HARDWARE

(MINIMUM 4)

EXTERIOR

WALL

EXTERIOR

WALL

EXTERIOR

SIGN

INSERT B + C: PRINTABLE

PAPER INSERT WITH

CLEAR ACRYLIC LENSE

INSERT A: 1-1/2" TACTILE

ROOM NUMBER WITH BRAILLE

To Be Determined2" 2"

4"

8"

8 1/2"

REMOVEABLE END CAPS

To Be Determined

9"

MEN

9"

3" 8"

INSERT B: TEXT: 1" TACTILE

ROOM DESCRIPTION WITH

BRAILLE

INSERT A: 6" TACTILE

SYMBOL

REMOVABLE END CAPS

8 1/2"

WOMEN

9"

3" 8"

INSERT B: TEXT: 1" TACTILE

ROOM DESCRIPTION WITH

BRAILLE

INSERT A: 6" TACTILE

SYMBOL

REMOVABLE END CAPS

8 1/2"

NO SMOKING OR

VAPING WITHIN 50

FEET OF BUILDING

NO SMOKING SYMBOL

1/2" MESSAGE

8 1/2"

1/

2"

NO VAPING / ELECTRONIC

CIGARETTE SYMBOL

TO MATCH PANTONE RED 185c

WHITE BACKGROUND WITH

BLACK ART AND BORDER

EXIT

REMOVEABLE END CAPS

3"

9"

INSERT A: 3/4" TACTILE

TEXT WITH BRAILLE

8 1/2"

INSERT B: PRINTABLE

PAPER INSERT WITH

CLEAR ACRYLIC LENSE

INSERT A: 1-1/2" TACTILE

ROOM NUMBER WITH BRAILLE

2" 4"

9"

REMOVEABLE END CAPS

To Be Determined

6"

8 1/2"

1' - 2" +/- (VARIES PER TEXT REQUIREMENTS)

2" T

Y P

2" MESSAGE INSERTS WITH 5/8"

TACTILE ROOM NUMBER WITH

BRAILLE AND 1" ROOM NAME

REMOVABLE END CAPS

#### CONTINUE PANELS AS

NEEDED, MAXIMUM 4, PER

ADA MOUNTING LIMITATIONS

XXXX

XXXX

XXXX

XXXX

8"

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG501

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

S

IG

N A

G E

D

E

TA

IL

S

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149078

SCALE: 3" = 1'-0"

SIGNAGE DETAIL - BASIS OF DESIGN

C4

SCALE: 1/2" = 1'-0"

SIGNAGE DETAIL - TYPICAL INSTALLATIONS

C1

SCALE: 3" = 1'-0"

B1

SIGNAGE DETAIL - TYPICAL MOUNTING

(INTERIOR AND EXTERIOR)

SCALE: 3" = 1'-0"

B2

ROOM ID WITH DEPARTMENT

(PRINTABLE) - TYPE A

SCALE: 3" = 1'-0"

TOILET (MENS) - TYPE D

A1

SCALE: 3" = 1'-0"

TOILET (WOMENS) - TYPE E

A2

SCALE: 3" = 1'-0"

MANDATORY (NO SMOKING) - TYPE F

A3

SCALE: 3" = 1'-0"

MANDATORY (EXIT) - TYPE G

A4

SCALE:

3" 6" 1' - 0"

3" = 1' - 0"

SCALE:

1' - 0" 2' - 0" 4' - 0"

1/2" = 1' - 0"

SCALE: 3" = 1'-0"

B3

ROOM ID (PRINTABLE) - TYPE B

SCALE: 3" = 1'-0"

ROOM ID (MULTIPLE LOCATIONS) - TYPE C

B4

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

NOTES:

1. SUPPLY ELECTRICAL EQUIPMENT CALL OUT PER IFC 605.3.1.

SEE SIGNAGE SCHEDULE FOR LOCATIONS.

2. COORDINATE FINAL ELECTRICAL EQUIPMENT LOCATIONS IN

FIELD PRIOR TO ORDERING AND INSTALLATION.

TEXT: 3/4" ROOM NAME; MATCH

BASE STANDARD

TACTILE TEXT: 1-1/2" ROOM NUMBER;

MATCH BASE STANDARD COLOR####

ROOM ID

1/

2"

8 1/2"

ELECTRICAL EQUIPMENT

PROVIDE ELECTRICAL EQUIPMENT

INDICATOR IF ROOM CONTAINS

ELECTRICAL EQUIPMENT.

NAME

INSERT A-D:

3" MESSAGE INSERT WITH TACTILE

1-1/2" ARROWS AND TACTILE 1"

MESSAGE TEXT

CL

NOTES:

1. DIRECTIONAL SIGNS SHOWN ARE DESIGN SUGGESTIONS ONLY AND WILL VARY PER

TEXT REQUIREMENTS. ALL INFORMATION INCLUDING ROOM NAMES AND NUMBERS,

DIRECTIONS, ETC. MUST BE COORDINATED IN FIELD WITH OWNER PRIOR TO

ORDERING AND INSTALLATION.

2. ADD AND REMOVE PANELS AS NEEDED TO FIT EACH DIRECTIONAL.

3. INTERIOR GRADE FINISH.

4. NOTIFY ARCHITECT / INTERIOR DESIGNER OF RECORD OF IN FIELD IDENTIFICATION

AND NUMERICAL CHANGES.

5. LOCATIONS AND VERBIAGE MUST BE VERIFIED BY AE2 WITH MCB CAMP LEJEUNE.

PROVIDE SUBMITTAL TO DESIGNER OF RECORD PRIOR TO PROCUREMENT AND

FABRICATION.

6. HELVETICA NEUE 55 ROMAN TEXT, WHITE LETTERS AND NUMBERS ON

BACKGROUND. ROOM LETTERS AND NUMBERS RAISED 1/32" MIN. GRADE 2 BRAILLE

ON BACKGROUND COLOR.

2' - 0" (VARIES PER TEXT REQUIREMENTS)

T Y

P

2"

3" (TEXT START)

EQ EQ

NOTES:

1. SUPPLY ELECTRICAL EQUIPMENT CALL OUT PER IFC 605.3.1.

SEE SIGNAGE SCHEDULE FOR LOCATIONS.

2. COORDINATE FINAL ELECTRICAL EQUIPMENT LOCATIONS IN

FIELD PRIOR TO ORDERING AND INSTALLATION.

INSERT B: 3/4" TACTILE TEXT

INSERT A: 1-1/2" TACTILE ROOM

NUMBER WITH BRAILLE####

ROOM ID

6" 3"

9"

9"

REMOVEABLE END CAPS

ELECTRICAL EQUIPMENT

PROVIDE ELECTRICAL EQUIPMENT

INDICATOR IF ROOM CONTAINS

ELECTRICAL EQUIPMENT.

8 1/2"

INSERT B: 3/4" TACTILE

ROOM NAME

INSERT A: 1-1/2" ROOM

NUMBER WITH BRAILLE####

ROOM ID

5"

3"

INSERT C: 1/2" TACTILE

TEXT WITH SLIDER

AVAILABLE

1"

9"

9"

REMOVEABLE END CAPS

IN USE

8 1/2"

INSERT C: 1" TACTILE TEXT

WITH BRAILLE

INSERT B: 6" TACTILE

STAIR SYMBOL

INSERT A: 1-1/2" TACTILE STAIR

OR FLOOR IDENTIFICATION

WITH BRAILLE

1'

3" 8"

2" STAIR

XXX

9"

REMOVABLE END CAPS

8 1/2"

NOTES:

1. SIGN IS A METAL; 1/8" THICK PANEL.

2. SIGN IS MOUNTED PER LOCAL AUTHORITIES DIRECTION TO ALLOW FOR EASE OF

VIEWING AT A DISTANCE FOR EMERGENCY RESPONDERS.

3. SIGN IS LOCATED ON SITE FOR VISIBILITY BY SECURITY AND FIRE PERSONNEL.

4. CONTRACTOR TO CONFIRM FINAL QUANTITIES, LOCATIONS AND NUMBERS WITH

OWNER AND LOCAL AUTHORITY PRIOR TO ORDERING AND INSTALLATION.

##1'

2' - 4"

BUILDING NUMBER,

WHITE LETTERING

6" OR 8" TEXT

FIELD COLOR BROWN,

PANTONE #7532C

NOTES:

1. SIGN IS A METAL; 1/8" THICK PANEL.

2. SIGN IS TO INCLUDE THE BUILDING ADDRESS. THIS SIGN IS MOUNTED IN THE

VICINITY OF THE FRONT DOOR.

3. FINAL LOCATION AND QUANTITIES WILL BE COORDINATED IN FIELD WITH OWNER

PRIOR TO ORDERING AND INSTALLATION.

STREET NO.

TOWN, STATE

BUILDING ADDRESS,

WHITE LETTERING

2" TEXT1'

2' - 4"

FIELD COLOR BROWN,

PANTONE #7532C # #2"

8 1/2"

TACTILE TEXT: 1-1/2"

ROOM NUMBER

C202 - C214

RESTROOMS / JANITOR

BREAK AREAS

VERTEX SUITE

MO SUITE

MIL / XO SUITE

CONFERENCE

ELECTRICAL / COMM ROOMS

MECHANICAL ROOM (ROOF ACCESS)

URINALYSIS

C202 - C214

RESTROOMS / JANITOR

BREAK AREAS

VERTEX SUITE

MO SUITE

MIL / XO SUITE

CONFERENCE

ELECTRICAL / COMM ROOMS

MECHANICAL ROOM (ROOF ACCESS)

URINALYSIS

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG502

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

S

IG

N A

G E

D

E

TA

IL

S

C

O N

TI

N

U E

D

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

131490790

SCALE:

6" 1' - 0" 2' - 0"

1 1/2" = 1' - 0"

SCALE: 3" = 1'-0"

ROOM ID (EXTERIOR) - TYPE K

B2

SCALE: 3" = 1'-0"

DIRECTIONAL - GENERAL

C1

SCALE: 3" = 1'-0"

ROOM ID (PERMANENT) - TYPE J

B1

SCALE: 3" = 1'-0"

ROOM ID (W/ SLIDER) - TYPE L

B3

SCALE: 3" = 1'-0"

ROOM ID (STAIRS) - TYPE M

B4

SCALE: 1 1/2" = 1'-0"

FOR REFERENCE ONLY - EMERGENCY NUMBER

A1

SCALE: 1 1/2" = 1'-0"

FOR REFERENCE ONLY - BUILDING ADDRESS

A2

SCALE:

3" 6" 1' - 0"

3" = 1' - 0"

SCALE: 3" = 1'-0"

ROOM ID (DOOR HEADER) - TYPE N

A3

SCALE: 3" = 1'-0"

DIRECTIONAL - TYPE H - #80

C3

SCALE: 3" = 1'-0"

DIRECTIONAL - TYPE H - #79

C2

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

W A S H

NOTES:

1. INTERIOR GRADE FINISH.

2. REFER TO A-SERIES ELEVATIONS FOR HEIGHT ABOVE

FINISHED FLOOR.

2' - 6"

4'

F I R E

NOTES:

1. INTERIOR GRADE FINISH.

2. REFER TO A-SERIES ELEVATIONS FOR HEIGHT ABOVE

FINISHED FLOOR.

4'

2' - 6"

NOTICE

NOTES:

1. INTERIOR GRADE FINISH.

2. SIGN IS A FLEXIBLE MAGNETIC SHEET.

ORDNANCE RESTRICTIONS

BUILDING _______________

ROOM ___________________

PERSONNEL LIMIT ____ ___ PEOPLE

NET EXPLOSIVE WEIGHT LIMIT _____

POUNDS OF CLASS/DIVISION _______

2' - 6"

2'

1.4

E101 & E102

NOTES:

1. INTERIOR GRADE FINISH.

2. SIGN IS A FLEXIBLE MAGNETIC SHEET.

31'

1' - 0"

NOTES:

1. INTERIOR GRADE FINISH.

2. SIGN IS A FLEXIBLE MAGNETIC SHEET.

1' - 0"

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG503

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

S

IG

N A

G E

D

E

TA

IL

S

C

O N

TI

N

U E

D

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

131490800

SCALE:

6" 1' - 0" 2' - 0"

1 1/2" = 1' - 0"

SCALE: 1 1/2" = 1'-0"

C1

FOR REFERENCE ONLY -

DIRECTIONAL - EYE WASH

SCALE: 1 1/2" = 1'-0"

C2

FOR REFERENCE ONLY -

DIRECTIONAL - FIRE EXTINGUISHER

SCALE: 1 1/2" = 1'-0"

C3

RESTRICTIVE SIGN - TYPE O

SCALE: 1 1/2" = 1'-0"

C4

FIRE DIVISION SIGN - TYPE P

SCALE: 1 1/2" = 1'-0"

C5

FIRE SYMBOL SIGN - TYPE R

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

SATISFACTORY TO DATE

APPROVED

ACTIVITY

FOR COMMANDER NAVFAC

SEAL

A/E INFO

A

B

C

D

1 2 3 4 5

1 2 3 4 5

A

B

C

D

SCALE:

CONSTR. CONTR. NO.

SHEET

NAVFAC DRAWING NO.

DES DRW CHK

OF

EPROJECT NO.:

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y N

A V

A L

F A

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S T

E M

S C

O M

M A

N D

DRAWFORM REVISION: 25 AUGUST 2020

N A

V A

L

FA

C

IL

IT

IE

S E

N G

IN

E

E R

IN

G

S Y

S

TE

M S

C O

M M

A N

D W

A S

H

IN

G

TO

N

100 AIRSIDE DRIVE

MOON TOWNSHIP, PA 15108

W A

S H

IN

G

T O

N D

C

AS NOTED

1665143

N40080-22-D-0001

PROJECT / DESIGN MGR

BRANCH MANAGER

CHIEF ENG / ARCH

FIRE PROTECTION

N A

S P

A X

R

IV

E R

M

D

T.WETTENGEL

C.GUTH

S.SO

DP1-C - IFC SUBMISSION - 03 MAY 2024

E.WEECH

IG601

F Y

H

A

E H

A N

G A

R L

IF

E

E X

T E

N S

IO

N

S

IG

N A

G E

S

C H

E D

U

LE

S

RLZ

SJK SJK

M A

R Y

L A

N D

N A

S P

A T

U X

E N

T R

IV

E

R

13149081

SCHEDULE - SIGNAGE (LEVEL 1)

MARK

ROOM SIGN

NUMBER NAME TYPE MESSAGE COMMENTS

1 -- EXTERIOR K C116 I SUPPORT EQUIPMENT /HAZMAT

2 -- EXTERIOR K C116 I SUPPORT EQUIPMENT /HAZMAT

3 -- EXTERIOR G SEE SIGN DETAIL

4 -- EXTERIOR F SEE SIGN DETAIL

6 C114 STAIR A C115 I CENTRAL TECHNICAL PUBLICATIONS LIBRARY

7 -- ROADSIDE HANGAR M C114 I STAIR

8 -- WATERSIDE HANGAR M C114 I STAIR

9 -- ROADSIDE HANGAR A C113 I QUALITY ASSURANCE

10 -- WATERSIDE HANGAR A C113 I QUALITY ASSURANCE

11 -- WATERSIDE HANGAR J C112 I ELECTRICAL ROOM

12 C111A ELECTRICAL ROOM J C111 I ELECTRICAL ROOM

13 -- ROADSIDE HANGAR J C111 I ELECTRICAL ROOM

14 C108 PASSAGE A C109 I SECURITY OFFICE

15 C108 PASSAGE A C110 I BOEING OFFICE

16 -- ROADSIDE HANGAR B WATERSIDE HANGAR ACCESS

17 -- WATERSIDE HANGAR B ROADSIDE HANGAR ACCESS

18 C107 LOGS AND RECORDS A C107A I LOGS AND RECORDS I STORAGE

19 C106 MAINTENANCE CONTROL A C106A I OFFICE

20 -- ROADSIDE HANGAR C C105 I CHANGE MANAGEMENT OFFICE

C106 I MAINTENANCE CONTROL

C107 I LOGS AND RECORDS

21 -- WATERSIDE HANGAR C C105 I CHANGE MANAGEMENT OFFICE

C106 I MAINTENANCE CONTROL

C107 I LOGS AND RECORDS

22 -- ROADSIDE HANGAR A C104 I PR SHOP PILOT EQUIPMENT

23 C104 PR SHOP PILOT EQUIPMENT B C104B I LAUNDRY

24 C104 PR SHOP PILOT EQUIPMENT B C104A I STORAGE

25 -- WATERSIDE HANGAR A C104 I PR SHOP PILOT EQUIPMENT

26 -- WATERSIDE HANGAR J C103 I FIRE RISER ROOM

27 -- ROADSIDE HANGAR J C102 I MECHANICAL ROOM

28 C102 MECHANICAL ROOM M C101 I STAIR

29 C103 FIRE RISER ROOM M C101 I STAIR

30 -- ROADSIDE HANGAR M C101 I STAIR

31 -- WATERSIDE HANGAR M C101 I STAIR

32 -- EXTERIOR G SEE SIGN DETAIL

81 -- ROADSIDE HANGAR N C114

82 -- WATERSIDE HANGAR N C114

83 -- ROADSIDE HANGAR N C113

84 -- WATERSIDE HANGAR N C113

85 -- ROADSIDE HANGAR N C111

86 -- WATERSIDE HANGAR N C112

87 C111A ELECTRICAL ROOM N C111

88 -- WATERSIDE HANGAR N C108

89 -- ROADSIDE HANGAR N C108

90 -- WATERSIDE HANGAR N C105 - C107

91 -- ROADSIDE HANGAR N C105 - C107

92 -- WATERSIDE HANGAR N C104

93 -- ROADSIDE HANGAR N C104

94 -- WATERSIDE HANGAR N C103

95 -- ROADSIDE HANGAR N C102

96 -- WATERSIDE HANGAR N C101

97 -- ROADSIDE HANGAR N C101

98 -- WATERSIDE HANGAR P SEE SIGN DETAIL

99 -- WATERSIDE HANGAR O SEE SIGN DETAIL

100 -- WATERSIDE HANGAR R SEE SIGN DETAIL

101 -- ROADSIDE HANGAR P SEE SIGN DETAIL

102 -- ROADSIDE HANGAR O SEE SIGN DETAIL

103 -- ROADSIDE HANGAR R SEE SIGN DETAIL

SCHEDULE - SIGNAGE (LEVEL 2)

MARK

ROOM SIGN

NUMBER NAME TYPE MESSAGE COMMENTS

51 C202.1 PASSAGE M C210 I STAIR

52 C202.1 PASSAGE J ROADSIDE HANGAR ACCESS

53 C211 MEN D SEE SIGN DETAIL

54 C202.1 PASSAGE J C212 I JANITOR

55 C213 WOMEN E SEE SIGN DETAIL

56 C202.1 PASSAGE J C214 I MECHAHNICAL ROOM (ROOF ACCESS)

57 C202.1 PASSAGE B C208 I URINALYSIS OFFICE

58 C202.1 PASSAGE J C207 I POP ROOM

59 C206 VERTEX A C206 A - B I VERTEX SUITE

60 C206 VERTEX A C206A I OFFICE

61 C206 VERTEX A C206B I OFFICE

62 C202.1 PASSAGE J C209 I ELECTRICAL

63 C202.1 PASSAGE L C205 I CONFERENCE ROOM

64 C202.1 PASSAGE L C205 I CONFERENCE ROOM

65 C202.1 PASSAGE A C204 A - C I MO SUITE

66 C204 MO SUITE A C204A I OFFICE

67 C204 MO SUITE A C204B I OFFICE

68 C204 MO SUITE A C204C I OFFICE

69 C204 MO SUITE A C204D I OFFICE

70 C202.1 PASSAGE A C203 A - D I MIL / XO SUITE

71 C203 MIL/XO SUITE A C203A I OFFICE

72 C203 MIL/XO SUITE A C203B I OFFICE

73 C203 MIL/XO SUITE A C203C I OFFICE

74 C203 MIL/XO SUITE A C203D I OFFICE

75 C202.1 PASSAGE A C202 A - B I UNASSIGNED SUITE

76 C202 UNDETERMINED TEAM A C202A I OFFICE

77 C202 UNDETERMINED TEAM A C202B I OFFICE

78 C202 UNDETERMINED TEAM M C201 I STAIR

79 C202.1 PASSAGE H SEE SIGN DETAIL

80 C202.1 PASSAGE H SEE SIGN DETAIL

NOTES - SIGNAGE

1 REFER TO ABAAS REQUIREMENTS REGARDING SIGN MOUNTING HEIGHT,

USE OF PICTOGRAMS, FINISH AND CONTRAST.

2 SIGN FINISHES, STYLES AND COLORS ARE LISTED ON THE SIGNAGE

DETAILS IG SERIES DRAWINGS.

3 SIGNS MOUNTED ON THE EXTERIOR ARE CONSTRUCTED OF DURABLE

FACTORY-FINISHED BAKED ENAMEL WITH REFLECTIVE SHEETING AND

MUST CONFORM TO MANUFACTURERS RECOMMEDATIONS FOR

APPLICATION. ALL EXTERIOR SIGNS MUST BE APPROVED BY OWNER

PRIOR TO ORDERING AND INSTALLATION.

4 SURFACE APPLIED VINYL LETTERS OR GRAPHICS THAT CAN BE RUBBED

OFF OR DAMAGED AND EXPOSED PAPER INSERTS ARE PROHIBITED.

5 CONTRACTOR PROVIDES SOFTWARE, ADDITIONAL MESSAGE SLOTS FOR

FUTURE INSERTS AND ATTIC STOCK FOR SIGNS; COORDINATE WITH

OWNER.

5 PROVIDE REQUIRED MOUNTINGS / HANGING MECHANISMS FOR SPECIFIED

SIGNS PER MANUFACTURERS RECOMMENDATIONS FOR LOAD. EXTERIOR

FASTENERS ARE CONCEALED AND RUST PROOF.

6 FINAL ROOM NAMES, NUMBERS AND NUMERIC REPRESENTATIONS ARE

COORDINATED WITH OWNER.

7 CONTRACTOR PROVIDES 3D FLAG SIGNS INDICATING DEFIBRILLATOR, FIRE

EXTINGUISHER AND EYE WASH LOCATIONS AT A MINIMUM. LOCATE SIGNS

ABOVE EACH DEVICE. COORDINATE REQUIRED 3D FLAGS WITH LOCAL

AUTHORITY HAVING JURISDICTION.

8 CONTRACTOR TO COORDINATE FINAL DEVICE RELATED SIGNAGE WITH

DISCIPLINE DRAWINGS AND LOCAL AUTHORITY HAVING JURISDICTION.

9 DIRECTIONAL SIGNS ARE DESIGN SUGGESTIONS ONLY. INFORMATION,

INCLUDING ROOM NAMES AND NUMBERS, DIRECTIONS, ETC.; ARE

COORDINATED IN FIELD WITH OWNER PRIOR TO ORDERING AND

INSTALLATION. NOTIFY ARCHITECT OF RECORD OF IN FIELD

IDENTIFICATION AND NUMERICAL CHANGES.

S Y

M D

E S

C R

IP

T

IO

N

D A

T E

A P

MAY 03, 2024

STRUCTURAL INTERIOR DESIGN

ISSUED FOR CONSTRUCTION SUBMISSION

DP1-C CENTER LEAN-TO, H115 AE HANGAR LIFE EXTENSION

ACOUSTICAL CEILING PANEL (ACP1)

MANU: ARMSTRONG

STYLE: ULTIMA HIGH NRC BEVELED

TEGULAR

COLOR: 1942 WHITE

SIZE: 24” x 24”, 9/16” GRID

PAINT (P1, P2)

MANU: SHERWIN WILLIAMS

COLOR: SW7757 HIGH

REFLECTIVE WHITE

FINISH: (P1) FLAT,

(P2) EPOXY SEMI-GLOSS

WINDOW TREATMENT (WT1)

MANU: SWF CONTRACT

STYLE: MANUAL ROLLER 3%

OPEN, E300 ETERNITY

COLOR: C1501 WHITE

STAINLESS STEEL (STL1)

MANU: WALLGUARD OR EQUAL

STYLE: STANDARD COUNTER GAUGE

COLOR: BRUSHED STAINLESS

(BINDER SAMPLE N/A)

SIGNAGE FINISHES (N/A)

MANU: 2/90 SIGN SYSTEMS

STYLE: SLIDE

COLORS: 734 DARK GRAY,

708 SOFT WHITE

CORNER GUARD (CG1)

MANU: CS-GROUP

STYLE: VINYL W/ ALUMINUM RETAINER

COLOR: 934 PEARL

SIZE: 8”H, 3”LEGS

PAINT (P7)

DOOR & TRIM PAINT (STAIRS), FE’S

MANU: SHERWIN WILLIAMS

COLOR: SW6871 POSITIVE RED

FINISH: SEMI-GLOSS

PAINT (P8)

EYE WASH

MANU: SHERWIN WILLIAMS

COLOR: SW6927 GREENBELT

FINISH: SEMI-GLOSS

SIGNAGE FINISHES (N/A) SAFETY

MANU: 2/90 SIGN SYSTEMS

STYLE: SLIDE

COLORS: 776 FOREST GREEN,

736 CARDINAL RED

STRUCTURAL INTERIOR DESIGN

ISSUED FOR CONSTRUCTION SUBMISSION

DP1-C CENTER LEAN-TO, H115 AE HANGAR LIFE EXTENSION

PAINT (P6)

TRIM & HANDRAIL PAINT

MANU: SHERWIN WILLIAMS

COLOR: SW7069 IRON ORE

FINISH: SEMI-GLOSS

WALL ACCENT PAINT (P5)

MANU: SHERWIN WILLIAMS

COLOR: SW7075 WEB GRAY

FINISH: EGGSHELL

QUARTZ COUNTER/SPLASH

(QZ1)

MANU: LG HAUSYS

STYLE: VIATERA, EASED EDGE

COLOR: EVEREST

WALL FIELD PAINT (P3), (P4)

MANU: SHERWIN WILLIAMS

COLOR: SW6385 DOVER WHITE

FINISH: (P3) EGGSHELL,

(P4) EPOXY SEMI-GLOSS

WOOD DOOR FINISH (N/A)

MANU: MASONITE

STYLE: ASPIRO SERIES, WALNUT

(PLAIN SLICED)

COLOR: COCOA BEAN

PLASTIC LAMINATE CASEWORK

(PL1)

MANU: FORMICA

COLOR: 00464-90 GRAYSTONE

FINISH: MATTE

SOLID SURFACE WINDOW STOOL

(SS1)

MANU: CORIAN

STYLE: EASED EDGE

COLOR: BISQUE

SOLID SURFACE COUNTERS &

SPLASHES (SS2)

MANU: CORIAN

STYLE: EASED EDGE

COLOR: ARTISTA CANVAS

SOLID SURFACE SHOWER PAN

(SS3)

MANU: CORIAN

STYLE: N/A

COLOR: DOVE

STRUCTURAL INTERIOR DESIGN

ISSUED FOR CONSTRUCTION SUBMISSION

DP1-C CENTER LEAN-TO, H115 AE HANGAR LIFE EXTENSION

CARPET TILE (CPT1)

MANU: SHAW CONTRACT GROUP

STYLE: 5T219 EXPANSE TILE,

ECOWORX BACKING

COLOR: 15580 RIDGE

SIZE: 12” X 48”

TILE INSTALL – ASHLAR

CARPET TILE (CPT2)

MANU: INTERFACE

STYLE: 127610AK0H, HN810

HUMAN NATURE

COLOR: 106487 TITANIUM

SIZE: 25 CM X 1 M

TILE INSTALL – HERRINGBONE,

TRAINING ROOMS ONLY

RUBBER FLOOR TILE & STAIR

TREAD (RF1), (RF2)

MANU: TARKETT

STYLE: GRHRTSP DEFIANT OIL AND

GREASE RESISTANT, HAMMERED

TEXTURE (RFI), (RF2)

SAFE T – GRIP SQUARE NOSE (RF2)

COLOR: 277 COLD FRONT,

40 BLACK INSERT STRIP

FLOOR COATING (C1)

MANU: TENNANT

STYLE: MIN. 3-PART FUEL RESISTIVE

RESINOUS FLOOR SYSTEM

COLOR: 56 SILVER GRAY

VINYL TILE SDT (VT1)

MANU: ARMSTRONG

STYLE: EXCELON SDT

COLOR: 51953 PEARL WHITE

SIZE: 12” X 12”

LUXURY VINYL TILE (LVT1)

MANU: MANNINGTON

STYLE: ACTIVE LINES

COLOR: ALG401 GRID POP

SIZE: 6" X 36“, STAGGERED INSTALL

FLOOR COATING (C2)

MANU: TENNANT

STYLE: MIN. 3-PART FUEL RESISTIVE

RESINOUS FLOOR SYSTEM

COLOR: 65 ROTUNDA RED

FLOOR COATING (C3)

MANU: TENNANT

STYLE: MIN. 3-PART FUEL RESISTIVE

RESINOUS FLOOR SYSTEM

COLOR: 30 RICH GREEN

FLOOR COATING (C4)

MANU: TENNANT

STYLE: MIN. 3-PART FUEL RESISTIVE

RESINOUS FLOOR SYSTEM

COLOR: 68 BRIGHT YELLOW

STRUCTURAL INTERIOR DESIGN

ISSUED FOR CONSTRUCTION SUBMISSION

DP1-C CENTER LEAN-TO, H115 AE HANGAR LIFE EXTENSION

PORCELAIN TILE - FLOOR (PT1),

(PTB1)

MANU: DALTILE

STYLE: IRONCRAFT

COLOR: IC13 CHARCOAL GREY

SIZE: (PT1) 12” X 24,

(PTB1) 6”H X 12” COVE

PORCELAIN TILE – WALL AND

ACCENT (PT2), (PT3)

MANU: DALTILE

STYLE: SOCIETY, LIGHT POLISHED

COLOR: SO45 MONUMENT WHITE

SIZE: (PT2) 12” X 24,

(PT3) 8”H X 48” STRIP

GROUT (GR1), (GR2)

MANU: LATICRETE

STYLE: SPECTRALOCK EPOXY

COLOR: (GR1) 60 DUST GREY,

(GR2) 90 LIGHT PEWTER

TOILET PARTITIONS (TP1), LOCKERS

MANU: SCRANTON

STYLE: SOLID HDPE, ORANGE PEEL

COLOR: CONCRETE

ENTRANCE MAT (EM1)

MANU:…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .