Attachment B - Specification_FINAL_1-12-22.pdf
PDF 969 KB Posted
- Attached to
- Olinda Substation Service Upgrades Project Federal contract opportunity
- Solicitation number
- 89503322BWA000003
- Issued by
- Department of Energy
About this file
This is a solicitation for the Olinda Substation Service Upgrades Project. The project involves upgrades at Olinda Substation near Cottonwood, California including installation of 230-kV bay equipment, replacement of station service transformers and switchgear, installation of concrete foundations and metal structures. A site visit will be held on February 10, 2022 and bids are due by an unspecified date. The North American Industry Classification System code is 237130 and this is a 100% small business set-aside contract with an estimated value between $1,000,000 and $5,000,000 awarded by the Department of Energy. Safety protocols related to COVID-19 will be enforced at the mandatory site visit, including social distancing, masks and limits on the number of attendees per company.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Pre-Proposal Site Visit.pdf | ||
| 89503322BWA000003 Amend 0002.pdf | ||
| oda_1190.pdf | ||
| Amendment 0001 - 89503322BWA000003.pdf | ||
| Attachment D - WD CA20210007.pdf | ||
| Attachment E - Responsibility.pdf | ||
| Solicitation 89503322BWA000003.pdf | ||
| Attachment C -Drawings_09_30_21.pdf | ||
| Attachment A - BiddingSchedule.xls | XLS spreadsheet |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OLINDA SUBSTATION
STATION SERVICE UPGRADES
Spec No. 960
SECTION C
DESCRIPTION/SPECIFICATIONS
CALIFORNIA
SECTION C
DESCRIPTIONS/SPECIFICATIONS
OLINDA SUBSTATION STATION SREVICE UPGRADES
DIVISION 1 – GENERAL REQUIREMENTS
A. CONTRACT REQUIREMENT
B. DESCRIPTION OF WORK
1. The Principal Components of Work
C. DESCRIPTION OF BIDDING SCHEDULE ITEM
1. Bidding Schedule item “Mobilization and preparatory work”
D. COMMENCEMENT, PROSECUTION AND COMPLETION OF WORK
1. Submittal Approval Time
2. Commencement of Control Work
3. Outage Restrictions
4. Construction Schedule Restrictions
5. Protective Ground Leads
6. Maximum Available Fault Current
7. Typical Foundations for Government-Furnished Electrical Equipment
8. Typical Foundations for Contractor-Furnished Electrical Equipment
E. CONSTRUCTION SCHEDULE
1. Submittal Time
2. Format and Detail
F. MATERIAL
1. Points-of-Delivery
G. GEOLOGIC INVESTIGATIONS
H. ELECTRIC POWER FOR CONSTRUCTION PURPOSES
I. WATER FOR CONSTRUCTION PURPOSES
J. EXPLOSIVES AND BLASTING
K. BURIED UTILITIES
L. EMPLOYEE REQUIREMENTS
M. ELECTRICAL MINIMUM APPROACH DISTANCES
N. SUBMITTALS AND CORRESPONDENCE
1. General
2. Transmittal
3. Submittal Response
4. Physical Sample Submittals
5. Project Protocol
DIVISION 2 – SITEWORK
A. DESCRIPTION OF BIDDING SCHEDULE ITEMS
1. Bidding Schedule item “Miscellaneous sitework”
2. Bidding Schedule item “Demolition”
3. Bidding Schedule does not contain separate items
DIVISION 3 – CONCRETE
A. GENERAL
1. Material
2. Test for Potential Reactivity of Sand and Coarse Aggregate
3. Rebar Development (LD) and Lap Length
B. DESCRIPTION OF BIDDING SCHEDULE ITEMS
1. Bidding Schedule item “Concrete foundations”
2. Bidding Schedule item “Cable trench (Government-furnished)”
3. Bidding Schedule item “Concrete pull boxes (Government-furnished)”
4. Bidding Schedule item “Concrete encasement”
DIVISION 4 – SUBSTATION METALWORK
A. GENERAL
1. Measurement
2. Measurement
B. DESCRIPTION OF BIDDING SCHEDULE ITEMS
1. Bidding Schedule item “Steel structures, welded (galvanized) (Government-furnished)”
2. Bidding Schedule item “Steel structures, welded (galvanized)”
DIVISION 9 – SUBSTATION - ELECTRICAL
A. GENERAL
1. Bidding Schedule for Government-furnished items
2. Bidding Schedule for items (not furnished by the Government)
3. Associated Support Structures Provided for each Electrical Equipment Rated Above 7-kV
4. Installation and Painting of Electrical Equipment and Material
B. DESCRIPTION OF BIDDING SCHEDULE ITEMS
1. Bidding Schedule item “Station service voltage transformer, 230-kV, 333-kVA (Government-furnished)”
2. Bidding Schedule item “Motor-operated disconnecting switch 230-kV, 2,000-amps with whips
(Government-furnished)”
3. Bidding Schedule item “Surge arrester, 192-kV Duty Cycle, 152-kV MCOV (Government-furnished)”
4. Bidding Schedule item “Free-standing automatic transfer switch, 480 V, 1200 amps, three-phase (Government-furnished)”
5. Bidding Schedule item “Station service transformer (Government-furnished)”
6. Bidding Schedule item “Temporary 1/0 AWG, 35-kV, insulated copper cable”
7. Bidding Schedule item “1/0 AWG, 35-kV, insulated copper cable (Government-furnished)”
8. Bidding Schedule item “Safety Switches (Government-furnished)”
9. Bidding Schedule item “Shielded 500 MCM 600 V Insulated conductors
(Government-furnished)”
10. Bidding Schedule item “Shielded Insulated conductors”
11. Bidding Schedule item “Outdoor AC main distribution switchboard”
12. Bidding Schedule items “Installing Government-furnished 12/c No. 10 AWG control cable”
13. Bidding Schedule items “Installing Government furnished 2/c No. 6 AWG control cable”
14. Bidding Schedule items “Installing Government-furnished RS-485 communication cable”
15. Bidding Schedule item “Associated electrical equipment and material”
16. Bidding Schedule item “Existing outdoor electrical equipment and material”
DIVISION 13 – ENVIRONMENTAL QUALITY PROTECTION
A. GENERAL
1. Submittals
2. Prevention of Air Pollution
3. Western Area Power Administration, Sierra Nevada Idling Policy
4. Materials with Lead-Based Paint and / or Asbestos
5. Disposal of Waste Materials
6. Pollutant Spill Prevention, Notification and Cleanup
7. Contractor’s Liability for Regulated Material Incidents
8. Landscape Preservation
9. Preservation of Cultural and Paleontological Resources
10. Conservation of Biological Resources
DIVISION 15 – DRAWINGS
A. GENERAL
1. Construction Drawings
B. AS-BUILT DRAWINGS
1. General
2. Recording Information
3. Marking of Drawings
4. Drawing Review
5. As-Built Information to be Recorded
6. Submittals
DIVISION 1 – GENERAL REQUIREMENTS
A. CONTRACT REQUIREMENT:
Construct and complete Olinda Substation Station Service Upgrade, in accordance with the Construction Contract (Standard Form 1442); the Contract Clauses; WAPA’s Construction Standards, including Standard 1 – General Requirements (September 2016), Standard 2 – Sitework (September 2016), Standard 3 – Concrete (September 2016), Standard 4 – Substation Metalwork and Transmission Line Lattice Structures (September 2016), Standard 5 – Transmission Line Steel Pole Structures (September 2016), Standard 6 – Light Duty Steel Pole Structures (September 2016), Standard 7 – Wood Poles (September 2016), Standard 8 – Glued Laminated Structures (September 2016), Standard 9 – Substation – Electrical (September 2016), Standard 10 – Transmission Line – Electrical (September 2016), Standard 11 – Service Building (September 2016), Standard 12 – Painting (September 2016), Standard 13 – Environmental Quality Protection (September 2016), Standard 14 – Communication Facilities (September 2016), Standard 15 – Drawings (September 2016); Standard Drawings; and these Project Specifications and Drawings.
If a conflict occurs between the Project Specifications and the Construction Standards, the Project Specifications shall govern. The Project Specifications and the Drawings are used to take exceptions or provide additions to the Construction Standards. Some paragraphs in the Construction Standards will not apply to this job.
WAPA’s Construction Standards, Standard Drawings, and Electrical Equipment Standards are available at https://www.wapa.gov/DoingBusiness/SellingToWestern/Pages/what-western-buys.aspx.
WAPA Project Specifications and Construction Standards are explained in Standard 1 – General Requirements, Section 1.1.1, “Standards and Project Specifications”.
B. DESCRIPTION OF WORK:
1. THE PRINCIPAL COMPONENTS OF WORK include the following:
a. Installation of temporary 35-kV power cables.
b. Removal of existing Unit Substation DZA.
c. Removal of one (1) pad mount transformer designated KZ31A.
d. Removal of 375W standby generator and propane storage tank.
e. Installation of 230-kV bay including Government furnished motor operated disconnect switch, SSVT’s and associated material and equipment.
f. Installation of the following Government furnished items:
(1) One (1) pad mount transformer, one (1) automatic transfer switch, three (3) safety switches and 35-kV power cable.
g. Installation of one (1) main distribution switchboard designated DZA and associated station service equipment to include insulated conductors, conduit and concrete encased conduit.
Installation of concrete foundation and support structures for station service equipment.
Installation of precast cable trench.
h. Providing foundations for substation structures and electrical equipment. Installation
Government furnished galvanized steel structures.
i. Installing Government furnished pull boxes.
j. Removal of cable/equipment after station service cutover.
Paragraphs “Description of Bidding Schedule Items” in Divisions – 1, 2, 3, 4, 9 and 15 describe the work to be performed.
The work is located near Cottonwood, California as shown on Drawing ODA 0015. The jobsite address is: Olinda Substation, 18275 Gas Point Rd, Cottonwood, California, 96032.
C. DESCRIPTION OF BIDDING SCHEDULE ITEM:
1. Bidding Schedule item “Mobilization and preparatory work” includes the following:
a. Performing mobilization and preparatory work in accordance with Section H of the contract clauses.
b. Prepare and submit a Construction Schedule and furnish a Safety and Health Program.
D. COMMENCEMENT, PROSECUTION AND COMPLETION OF WORK: See FAR 52.211-10 in
Section F of the solicitation/contract.
1. SUBMITTAL APPROVAL TIME: Except as otherwise provided for specific submittals, WAPA will require 30-calendar days for review of drawings or data submitted for approval.
2. COMMENCEMENT OF CONTROL WORK: Do not perform any control board or outdoor equipment wiring until receipt of Government-furnished wiring diagrams. WAPA will furnish outdoor wiring diagrams and schematic diagrams as required. Include these restrictions in the Construction Schedule.
3. OUTAGE RESTRICTIONS: In addition to the restrictions listed in Construction Standard 1, the following outage restrictions shall apply:
a. Neither Cottonwood 1 nor Cottonwood 2 lines can be de-energized between the months of June-September.
b. Rigid bus shall be cut as shown on Drawings ODA 1020 and ODA 1154-2 EI to help isolate construction area bus. Provisions must be in place to reconnect removed bus sections using compression type couplers (DMC Power’s Bus & Cable Connectors and Swage System, AFL Swage system, or equal, within 24-hours due to an emergency situation.
c. Make all outage requests in writing to the onsite WAPA representative a minimum of
14-days in advance. Meeting the minimum advance notice requirement does not guarantee an outage will be approved. Weather conditions and other system conditions must be evaluated against an outage request before approval can be granted. At any time, WAPA may deny an outage request or direct the Contractor to return facilities to operating conditions and release the applicable Special Work Permit.
4. CONSTRUCTION SCHEDULE RESTRICTIONS: The following Construction Schedule restrictions shall apply:
a. The Contractor shall not work more than 12-hours per day and no more than 60-hours in one (1) continuous period without approval from the Contracting Officer’s Representative
(COR).
b. The Contractor shall submit a construction sequence plan detailing order of work and demolition. This plan shall be reviewed and approved by the COR. Work cannot commence until the plan has been approved.
c. Temporary 35-kV cables will be required to keep the existing station service equipment energized and in service while new station service equipment is constructed in parallel.
d. Distribution panels shall be cutover to the new station service one (1) at a time and left energized when Contractor is offsite.
5. PROTECTIVE GROUND LEADS: See WAPA Construction Standards, Standard 1 “General
Requirements”, Section 1.4.14.3(1).
6. MAXIMUM AVAILABLE FAULT CURRENT: When protective ground leads are required, the protective ground leads shall be sized as defined below and shall meet the requirements of Standard 1 – General Requirements, Section 1.4 “Safety and Health” and the following:
a. The maximum available fault current in the 230-kV area is 29,895 amps and the X/R ratio is 12.9 prior to completing construction and 29,895-amps and the X/R ratio is 12.9 after completing construction.
b. A minimum of one (1) (4/0) grounds shall be used in the 230-kV area.
c. The maximum available fault current in the KT1A 34.5-kV area is 8,307-amps and the X/R ratio is 109.9 prior to completing construction and 8,307-amps and the X/R ratio is
109.9 after completing construction.
d. A minimum of one (1) (4/0) grounds shall be used in the KT1A 34.5-kV area.
7. TYPICAL FOUNDATIONS FOR GOVERNMENT-FURNISHED ELECTRICAL EQUIPMENT:
Typical foundations are shown on Drawings ODA 2303 through ODA 2306.
8. TYPICAL FOUNDATIONS FOR CONTRACTOR-FURNISHED ELECTRICAL EQUIPMENT:
Typical foundations are shown on Drawings ODA 2303 through ODA 2306. Regarding foundations noted as “design not firm”: WAPA will design these foundations after receipt and final approval of seismic qualification documents and informational drawings and data from the Contractor.
E. CONSTRUCTION SCHEDULE:
1. SUBMITTAL TIME: Prepare and Submit a Construction Schedule to the Contracting Officer (CO) within 45-calendar days after date of Notice to Proceed.
2. FORMAT AND DETAIL: Dates for each item of Government-furnished material shall be provided.
Do not program dates earlier than the estimated delivery dates shown in the “Material” paragraph.
F. MATERIAL: Furnish all material for completing the work, except material furnished by WAPA as listed below:
ITEM
ESTIMATED
WEIGHT
(LBS)
ESTIMATED
DELIVERY
DATE
ESTIMATED
COST
1. Cable Trench 400 Onsite $1,000
2. Two (2) Precast Concrete Pull Boxes 8,000 Onsite $20,000
3. Steel Structures 10,000 Onsite
4. Three (3) single-phase, station service voltage transformers, 230-kV, 333-KVA designated
KY21A
11,500 ea Onsite $500,000
5. One (1) three-phase motor operated disconnecting switch, 230-kV, 2,000 amps with whips designated WY21A
11,200 Onsite $50,000
6. Three (3) single-phase, surge arresters, designate AY21A 450 ea Onsite $15,000
7. One (1) three-phase, free-standing automatic transfer switch, 480 V, 1200 amps
800 Onsite $30,000
8. One (1) station service transformer, 34.5-kV-480 V, three-phase, designated KZ31A
9,700 Onsite $30,000
9. 1/0 AWG, 35-kV, insulated copper cable N/A Onsite $15,000
10. Three (3) three-phase, 480 V, 1200A, Safety Switches 500 ea Onsite $30,000
11. One-thousand-feet (1,000 LF) 12/C No. 10 control cable N/A Onsite $5,000
1. POINTS-OF-DELIVERY: GFE Material furnished by WAPA is onsite at Olinda Substation. The
Contractor shall inspect the equipment and report any damages to the COR.
G. GEOLOGIC INVESTIGATIONS:
The 8000-series geologic logs of subsurface explorations included in the “Drawings” Division constitute the information and records of geologic investigations for the work. Locations of subsurface investigations are shown on the Drawings.
Samples and cores of recovered material were not retained. Bidders shall obtain their own samples and perform tests on the material to evaluate properties, which they believe to be significant. WAPA does not guarantee that the geologic information and records show the conditions that will be encountered in performing the work, but only that the geologic information and records show conditions encountered at the particular point and time the information and records were obtained.
The geologic information may not indicate variations, such as those caused by seasonal fluctuations in rainfall and other factors, which may affect the water level. The Contractor shall determine the nature of material to be excavated, the difficulties of making and maintaining required excavations, and doing other work affected by geology and ground water elevations at the worksite.
H. ELECTRIC POWER FOR CONSTRUCTION PURPOSES:
Electric power for construction purposes will be available without cost. Source of supply is located in the receptacles throughout the substation. The Contractor may furnish power for his operations by other means at no additional cost to WAPA. Power made available by WAPA will be delivered as single-phase, 60 Hz, AC, at approximately 120-240 V. Coordinate with the COR for establishing electric power service.
I. WATER FOR CONSTRUCTION PURPOSES:
Furnish water for construction purposes. Make arrangements for obtaining the water and provide for conveying the water to the points of use.
J. EXPLOSIVES AND BLASTING:
Explosives shall not be used.
K. BURIED UTILITIES:
Prior to excavation, examine the area and determine the location of buried utilities. Utilities shall be identified with a marker denoting the type of service.
L. EMPLOYEE REQUIREMENTS:
In addition to the requirements listed in WAPA Construction Standard 1.4.3 all employees are restricted from wearing a headset, headphone, or other listening device, other than a hearing aid or instrument for the improvement of defective human hearing, hearing protection worn as the hazard exists, or for communication purposes while on a WAPA jobsite.
M. ELECTRICAL MINIMUM APPROACH DISTANCES:
In addition to the requirements listed in WAPA Construction Standard 1.4.9 equipment other than cranes and derricks, conductive objects, or personnel, shall not be brought closer to energized facilities than the electrical minimum approach distances established by OSHA 1926.958(b), “Materials, Handling and Storage”. The less stringent equipment clearance distances established by OSHA 1926.960, “Working On or Near Exposed Energized Parts”, Table V-5 and Table V-6, may only be used after the Contractor has completed and submitted WAPA’s Electrical Clearance Variance form and has received the signed form in return from the COR.
N. SUBMITTALS AND CORRESPONDENCE:
1. GENERAL: Submittals must be provided in accordance with the Construction Standards and Project Specifications. The Contractor shall furnish submittals electronically (i.e. e-mail), unless otherwise specified by the COR. Submittals shall be sent to Sierra Nevada Region (SNR) in standard PDF or electronic CAD “*.dwg” (AutoCAD 2016) formats. All submittals shall include WAPA’s Contract No., Project Title, Transmittal/Submittal No. and corresponding Item No. Refer to the Submittal Log for the list of required submittals. This list may not be all-inclusive and it remains the Contractor’s responsibility to ensure conformance to the individual Specifications for possible additional submittal requirements. All submittals must be submitted with the attached SNR transmittal cover sheet.
In addition to the submittals required in the attached Submittal Log, the Contractor shall submit the following to SNR:
a. Payrolls.
b. Subcontractor List/Forms.
c. Citizenship Forms.
d. Erosion Control Plan.
e. Environmental Submittals.
f. Request For Information (RFI.)
g. Request for Equitable Adjustment (REA).
h. Any questions comments, correspondence relevant to this project.
A submittal is required if the item is used in the performance of this contract.
2. TRANSMITTAL: The Contractor shall submit all correspondence (Request for Information, Submittals, etc.) to the following email addresses care of the COR.
Sierra Nevada Region ATTN: N5700 Sergio Vivar Email: XXXX@wapa.gov
3. SUBMITTAL RESPONSE: WAPA will provide a response to all submittals in accordance with
Division 1.D.2 of these specifications with an “Acceptable” or “Not Acceptable” status, with comments as appropriate to the email address where the submittals originated.
4. PHYSICAL SAMPLE SUBMITTALS: When physical specimens or digital media are required to be submitted for approval, (i.e. brick samples, roofing material samples, carpeting, CDs, DVDs, etc.) the Contractor shall provide a digital cover letter outlining the physical sample submittal prior to sending the sample (including tracking data when applicable) and shall deliver physical specimens to:
5. PROJECT PROTOCOL:
a. Electronic Correspondence:
SUBMITTAL FORMAT:
Subject Line
Transmittal number, Submittal number, Subject, Applicable Standard Number, and Project Name/Number Example: Transmittal 001, Submittal 017, Steel Compression Dead Heads-Std 10, Substation
Stage 06-DE-WA000xxxx
b. Payment Requests:
PAYMENT REQUEST FORMAT:
Invoice number and Project Name/Number Example: Invoice 01, Substation Stage 06 DE-WA000xxxx
c. Certified Payrolls-Prime and Sub-Contractors:
CERTIFIED PAYROLL FORMAT:
Certified Payroll (CP), Contractor’s names, Week ending (WE), and Project Name/Number Example: CP-(Smith Inc., Bob’s Electrical), WE 09/12/15 & 09/19/15, Substation Stage 06-DE-
WA000xxx
d. Request for Information:
(REQUEST FOR INFORMATION) FORMAT:
Request for Information (RFI), Project Name/Number Example: RFI-003, Labeling Info, Substation Stage 06-DE-WA000xxxx
TABLE 1 – SUBMITTAL INFORMATION GUIDELINE
Specifications
SECTION ITEM PR
O D
U C
T D
A
TA
SH
O
P D
R A
W
IN
G S
(p re lim in ar y fin al
C
A
LC
U
LA
TI
O
N S
IN
ST
A
LL
A
TI
O N
D
C O
LO
R
S A
M
PL
ES
M
IN
TE
N A
N C
E M
A
TE
R
IA
L
O
PE
R A
TI
O
N A
N D
M A
IN
T.
D
M
FR
W
IR
IN
G
D
IA
G R
A M
S
TE
ST
IN
G
R
EP
O R
TS
W
R R
A N
TY
C
ER
TI
FI
C A
TI
O
N S
O
M M
A N
U
LS
Division 1 Construction sequence plan ● ● Division 3 Concrete ●
Division 9 Temporary 1/0 AWG, 35-kV, insulated copper cable ●
Division 9 Shielded 500 MCM 600 V insulated conductors ●
Division 9 Shielded insulated conductors ●
Division 9 Outdoor AC main distribution panelboard ● ● ●
Division 9 2/c No. 6 AWG control cable ● Division 9 RS-485 communication cable ● Division 9 Cable terminators ● ● Division 9 Riser cable supports ● ● Division 9 Signs ●
This table does not reflect all submittals but references specific information required in the following submittals.
Refer to Division 13 Environmental Quality Protection section of the specifications for environmental submittal requirements.
DIVISION 2 – SITEWORK
A. DESCRIPTION OF BIDDING SCHEDULE ITEMS:
1. Bidding Schedule item “Miscellaneous sitework” includes the following:
a. Replacing and protecting existing gravel surfacing.
2. Bidding Schedule item “Demolition” includes the following:
a. Completely removing disposing of concrete foundations designated on Existing Installation Drawings ODA 2007 and ODA 2015.
3. Bidding Schedule does not contain separate items for the following. Include these items in applicable Bidding Schedule items.
a. Excavations for foundations, structures and trenches.
b. Placing and compacting earth material and backfill.
c. Providing gravel fill under concrete foundations as shown on the Drawings.
d. Disposing of excavated material. Material from excavations not suitable or required for earthwork shall be removed from the substation and access road right-of-way. The Contractor shall make arrangements required for disposal of waste material in an approved landfill.
e. Expansion anchors and adhesive anchors.
DIVISION 3 – CONCRETE
A. GENERAL:
1. MATERIAL:
a. Cement: Type IIA cement Types are according to ASTM C 150.
b. Compressive Strength: 4000-psi minimum at 28-days.
c. Water-Cement Ratio: Net water-cement ratio, exclusive of water absorbed by the aggregates, shall not exceed 0.45 by weight.
d. Type A and D water-reducing and retarding admixtures may be used if approved by the COR.
e. Class F fly ash is required to neutralize severe alkali or ASR reaction in accordance with ASTM C 311 (regarding test data), ASTM C 618 (regarding material) and Standard 3 – Concrete (regarding WAPA-specific requirements). Proposed concrete mix designs shall incorporate fly ash up to a maximum of 20 percent; minimum 28-day compressive strength shall be maintained in mix design.
2. TEST FOR POTENTIAL REACTIVITY OF SAND AND COARSE AGGREGATE: Perform test for each source used. Perform tests for potential reactivity for the sand and coarse aggregate to be used by the Contractor. If the tests determine the aggregate(s) to be unsuitable as a concrete aggregate, a suitable source will be obtained by the Contractor.
3. REBAR DEVELOPMENT (LD) AND LAP LENGTH:
a. Class B lap splices apply unless noted otherwise; refer to Table 3 on Standard
Drawing 01 2004-1 General Outline and Reinforcement Notes.
b. Typical closed circular tie lap splice lengths for drilled piers and columns, 4,000 – 4,500-psi normal weight concrete, unless noted otherwise, are 18-inches for No. 3 ties, 24-inches for No. 4 ties, and 30-inches for No. 5 ties.
B. DESCRIPTION OF BIDDING SCHEDULE ITEMS:
1. Bidding Schedule item “Concrete foundations” includes the following:
a. Earthwork, formwork, reinforcement, material used in concrete, galvanized anchor bolts, curing, finishing, joints and other related work and material needed to complete the concrete construction.
b. Concrete foundations for steel structures.
c. Concrete foundations for electrical equipment.
d. Concrete foundation for station service equipment including aluminum trench covers.
e. Casing auger excavations, if required.
f. Trial augering, if required.
g. Measurement for quantities for concrete foundations will be made on the basis of concrete quantities shown on Drawing ODA 2018.
2. Bidding Schedule item “Cable trench (Government-furnished)” includes installing
Government-furnished precast concrete cable trench, complete with contoured gravel surface to support cables, aluminum covers and patching existing trench wall as shown on ODA 2500.
3. Bidding Schedule item “Concrete pull boxes (Government-furnished)” includes installing
Government-furnished precast concrete pull boxes, complete with gravel-fill, protection bollards and other accessories as shown on Drawings ODA 1730 and ODA 1731.
4. Bidding Schedule item “Concrete encasement” includes installing a 3-inch envelope of concrete around medium voltage conduits as indicated on ODA 1720. The encasement shall include a minimum of 3000-psi concrete with a maximum 3/4-inch aggregate, a 3-inch envelope of concrete surrounding all conduits and vibrated or carefully spaded to eliminate voids. Do not use power-driven agitating equipment unless specifically designed for duct-bank application.
Conduit supports shall be placed close enough to prevent sagging and deforming of ducts, with not less than five (5) spacers per 20-feet of duct. Secure supports to earth and to ducts to prevent floating during concreting. Do not use tie wires or reinforcing steel that may form conductive or magnetic loops around ducts or duct groups and do not allow a heavy mass of concrete to fall directly onto ducts. This bidding item is for concrete encasement only, conduits shall be included with associated electrical equipment and material bidding item.
Install concrete encased conduit at least 24-inches below finished grade in areas not subject to deliberate traffic and at least 30-inches below finished grade in deliberate traffic paths for vehicles, unless otherwise indicated.
DIVISION 4 – SUBSTATION METALWORK
1. MEASUREMENT: Measurement for quantities for Bidding Schedule items “Install steel” will be lump sum.
a. Lump sum shall include temporary cribbing, storage and erection of all steel structures listed in Section “B.1” below.
2. MEASUREMENT: Measurement for quantities for Bidding Schedule item “Steel structures, welded (galvanized)” will be made on the basis of weights calculated in accordance with LRFD, “AISC Code of Standard Practice for Steel Buildings and Bridges”, except those weights for nonrectangular shapes and plates are to be based on actual detailed dimensions.
a. Steel structure weights, calculated as noted above, shall be shown on the Contractor-furnished final shop drawings and payment will be based thereon. Steel estimated weights are shown on the specifications drawings for the structures requiring approval drawings as noted in the Bidding Schedule items “Steel structures, welded (galvanized)”.
1. Bidding Schedule item “Steel structures, welded (galvanized) (Government-furnished)” includes installing the following:
a. Two (2) – Bus Frames - Type III.
b. One (1) – Bus Frame - Type IV.
c. Two (2) – Bus Pole - Type II.
d. One (1) – Single Switch Platform – Type I including grating.
e. Three (3) – Equipment Cabinet Platform – Type V including grating.
f. One (1) – Station Service Equipment Support Frame.
g. One (1) – Safety Switch Support Frame.
h. Three (3) – Surge Arrester Equipment Supports.
2. Bidding Schedule item “Steel structures, welded (galvanized)” includes providing and installing the following:
a. One (1) ATS Support Frame.
b. One (1) DZA Support Frame.
Structures listed above require approval drawings.
The above material including connection bolts, nuts, washers and lock nuts shall be galvanize.
DIVISION 9 – SUBSTATION - ELECTRICAL
A. GENERAL: Electrical equipment and material shall be as specified in Western’s “WAPA ES” Standard Equipment Specifications, as shown on project drawings and in accordance with NEMA, ANSI, IEEE, ICEA, ASTM, NEC, NESC, UL and Federal specifications and standards as applicable.
Applicable requirements shall be met under the following service conditions:
Ambient Temperatures:
Maximum ......................................................................................... +40°C Maximum 24-Hour Average ............................................................ +30°C Minimum ........................................................................................... -30°C
Elevation:
Above Mean Sea Level ............................................................... 490-Feet
*ASCE-7 Wind Load:
Minimum Basic Wind Speed ........................................................ 90 MPH Importance Factor .............................................................................. 1.15
*IEEE 693 Seismic Qualification .................................................................... High
*May include support structure in accordance with STANDARD 9.1.1.2. Wind and seismic loads are nonsimultaneous.
1. Bidding Schedule for Government-furnished items (including associated supporting structures when furnished) require the Contractor to provide:
a. Unless otherwise indicated, unloading and inspecting Government-furnished items.
b. Installing Government-furnished items as shown on drawings.
c. Furnishing equipment and material not furnished by WAPA
2. Bidding Schedule for items (not furnished by the Government) shall be furnished by the
Contractor and shall include the following:
a. Providing (furnishing and installing) bidding schedule items.
b. Furnishing equipment and material not furnished by WAPA.
c. Installing bidding schedule items as shown on drawings.
3. Unless otherwise specified, associated support structures provided for each electrical equipment rated above 7-kV shall be 102-inches in height and hot-dip galvanized, if made of steel.
Instrument transformers that are seismically qualified shall be 96-inches in height. If tubular steel supports are furnished, they shall be galvanized internally and externally.
4. Installation and painting of electrical equipment and material shall be provided in accordance with
Standards 9 and 12 respectively.
1. Bidding Schedule item “Station service voltage transformer, 230-kV, 333-kVA (Government-furnished)” includes furnishing all equipment and material not furnished by WAPA and installing the Government-furnished station service voltage transformers with support structures:
DESIGNATION KY21A
Type Station Service Voltage Transformer
Nominal Voltage Rating (kV) 230/132.8 Gnd Y
Maximum Voltage Rating (kV) 245
Basic Impulse Level (kV) 900 Primary Power Winding Voltage (kV) 132.8
High-Voltage Taps (percent) ±2.5, ±5.0
Secondary Power Winding Voltage (single-phase, 3-wire) 480 V
Capacity (kVA) 333
One (1) minute Emergency Over Voltage Operation 125 percent
Mounting Base
The station service voltage transformers KY21A are on-site. Contractor personnel shall inspect the transformers for possible damage and report any damage to WAPA’s COR.
2. Bidding Schedule item “Motor-operated disconnecting switch 230-kV, 2,000-amps with whips (Government-furnished)” includes furnishing all equipment and material not furnished by WAPA and installing the Government-furnished motor-operated disconnecting switch with associated support structure:
DESIGNATION WY21A
Type 3 pole, single throw, outdoor, motor group operated, vertical break, rotating insulator
System Nominal Voltage Rating (kV) 230
Model Mindcore AVX23020
Rated Maximum Voltage (kV) 245
Basic Impulse Insulation Level (kV) 900
Continuous Current Rating (Amps) 2,000
DESIGNATION WY21A
Short-Time (3 seconds) Symmetrical Current Rating (kA)
Peak Withstand Current (kA @ 60Hz) 164
Grounding Blades No
Arcing Horns Whip type
Switch Operator Type Motor Operator
Phase Spacing (FT) 12-0
Height of Support Structure (FT) 8-6
Mounting Position Horizontal
Insulator Technical Reference No. 304
Control Circuit Voltage 125VDC
Auxiliary Switch Connected to the operating mechanism
Key Interlock None
Minimum whip interrupting capability 2 amps
The 230-kV motor-operated disconnect switch WY21A is onsite. Contractor personnel shall inspect the disconnect switch for possible damage and report any damage to WAPA’s COR.
3. Bidding Schedule item “Surge arrester, 192-kV Duty Cycle, 152-kV MCOV (Government-furnished)” includes furnishing all equipment and material not furnished by WAPA and installing the Government-furnished Surge Arresters:
DESIGNATION AY21A1, AY21A2, AY21A3
Class Station
System kV (L-L) 230
Duty Cycle Voltage (kV) 192
MCOV 152
4. Bidding Schedule item “Free-standing automatic transfer switch, 480 V, 1200 amps, three-phase (Government-furnished)” includes furnishing all equipment and material not furnished by WAPA and installing the Government-furnished Automatic Transfer Switch:
DESIGNATION ATS
Type Free-standing, self-contained, metal enclosed, three-phase, 60 Hz
Required Voltage Rating 480 V
Enclosure Type 3RX Outdoor
Transition type Contactor based
Source continuous current rating (amps) 1200
Momentary current 10 cycle Asym, (kA) 65
Operation type Open (break before make)
Poles 4
Switched neutral Yes
The automatic transfer switch is onsite. Contractor personnel shall inspect the ATS for possible damage and report any damage to WAPA’s COR.
5. Bidding Schedule item “Station service transformer (Government-furnished)” includes furnishing all equipment and material not furnished by WAPA and installing the Government-furnished station service transformer:
DESIGNATION KZ31A
Type Pad mounted, three-phase, 60 Hz, outdoor, self-cooled, FR3 oil filled, Loop Feed, dead front Voltage Rating 34.5-kV delta to
480/277-V grounded wye
High-Voltage Taps (percent) ±2.5, ±5.0
Capacity (kVA) 1000
Impedance (minimum) 5.75% Z Number of High-Voltage Bushing Wells 6
Number of Low-Voltage Bushings with NEMA Pads 4
High-Voltage BIL (kV) 150
Low-Voltage BIL (kV) 30
DESIGNATION KZ31A
Primary side fuse No
Station service transformer KZ31A is onsite. Contractor personnel shall inspect the station service transformer for possible damage and report any damage to WAPA’s COR.
a. Transformer KZ31A may include the following accessories:
(1) High voltage parking stands mounted adjacent to high-voltage bushing wells.
(2) Four (4) 35-kV Class, 200 amp loadbreak terminating elbows (includes one (1) spare).
(3) Six (6) 35-kV Class Bushing well inserts.
(4) Six (6) 35-kV Class Bushing wells.
(5) Three (3) 36-kV Class metal oxide varistor (MOV) surge arresters with mating
200-amp loadbreak elbow interface.
6. Bidding Schedule item “Temporary 1/0 AWG, 35-kV, insulated copper cable” includes providing 1/0 AWG, 35-kV, insulated copper power cable type MV-105, 133 percent insulation level, Southwire Simpull NL-EPR, or equal, as shown on the Drawings. Temporary cables shall run from FZ31A to KZ31A and shall be adequately protected from damage during construction.
Cable runs are three-phase.
7. Bidding Schedule item “1/0 AWG, 35-kV, insulated copper cable (Government-furnished)” includes installing Government-furnished 1/0 AWG, 35-kV, insulated copper power cable type MV-105, 133-percent insulation level, as shown on the Drawings. Cables shall run from FZ31A to KZ31A as shown on drawings. Cable runs are three-phase.
8. Bidding Schedule item “Safety Switches (Government-furnished)” includes installing three
(3) Government-furnished safety switches as shown on the Drawings. Safety Switches are designated SSA, SSB and SSC.
9. Bidding Schedule item “Shielded 500 MCM 600 V insulated conductors” 7,000 feet of
500MCM shielded insulated conductor is onsite at Olinda Substation as Government-furnished equipment. The conductor is Basic Wire and Cable catalog number 5-120-SJ. The Contractor shall furnish additional cable (approximately 3,000 feet) needed to complete installation. The Contractor shall install all 500MCM conductor including GFE conductor as shown on the drawings.
All 500MCM insulated conductors shall be shielded as described in Section 9.2.3.2(5) of the construction standards. No splicing of cables shall be allowed except for approval from the COR.
10. Bidding Schedule item “Shielded insulated conductors” includes providing insulated conductors and cables except 500 MCM 600 V insulated conductors, 12/c No. 10 AWG and 2/c No. 6 AWG control cable, communication cable and power cable with insulation greater than 15,000 V. All insulated conductors shall be shielded as described in Section 9.2.3.2(5) of the construction standards. No splicing of existing cables shall be allowed except for approval from the COR.
11. Bidding Schedule item “Outdoor AC main distribution switchboard” includes providing and installing outdoor, floor mounted, AC switchboard system DZA as shown on Drawing ODA 1600.
The switchboard shall be flat roof, front access nonwalk-in style, Eaton Pow-R-Line C or equal.
Switchboard DZA shall consist of a 1200 amp, three-phase, 3-wire system rated 65kAIC withstand with core balance or similar ground fault detection scheme. The switchboard enclosure shall be stainless steel, NEMA 3R and a minimum 51-inches-wide by 43-inches-deep. The switchboard shall be in accordance with WAPA ES 2.3.3, 2.3.4 and 2.3.11 Equipment Standards.
12. Bidding Schedule items “Installing Government-furnished 12/c No. 10 AWG control cable” includes 12/c No. 10 AWG control cable. The Contractor shall install and terminate control cable in all outdoor equipment installed under this contract. WAPA will terminate control cable inside the control building. Provide sufficient cable to allow termination on the highest terminal block of switchboard CHB5 shown on Drawing ODA 4007 of the control building.
13. Bidding Schedule items “Furnishing 2/c No. 6 AWG control cable” includes furnishing 2/c
No. 6 AWG control cable.
14. Bidding Schedule items “Installing 2/c No. 6 AWG control cable” includes 2/c No. 6 AWG control cable. The Contractor shall install and terminate control cable in all outdoor equipment installed under this contract. WAPA will terminate control cable inside the control building.
Provide sufficient cable to allow termination plus 10-extra feet to the highest breaker of panelboard BHB1 shown on Drawing ODA 4007 of the control building.
15. Bidding Schedule items “Furnishing RS-485 communication cable” includes furnishing
RS-485 communication cable. RS-485 communication cable shall be outdoor rated CPE jacket, 2 pair, #22 AWG cable, Belden catalog #3107DB or equal.
16. Bidding Schedule items “Installing RS-485 communication cable” includes installing
RS-485 communication cable. The Contractor shall install communication cable and terminate at the ATS. WAPA will terminate the other end of the cable at the RTU inside the control building.
Provide sufficient cable to allow termination plus 10-extra feet to RTU No. 1 shown on Drawing ODA 4007 of the control building.
17. Bidding Schedule item “Associated electrical equipment and material” includes providing equipment, material and services required to complete the following substation installations as shown on the Drawings:
a. Electrical Testing: Includes providing electrical testing in accordance with Standard 9, paragraph 9.1.2 Acceptance Tests – Method A.
b. Substation Grounding System: Repair and complete the substation grounding system.
Unless otherwise specified on drawings, splices, connections and other fittings may be compression type (DMC Power’s Swage, AFL Swage system, or equal. It’s recommended to obtain the necessary tooling from the respective manufacturer). Due to ongoing copper theft problems, all new exposed ground wire shall be copper clad steel. NOTE: The included drawings and standards have not been revised to show this new requirement.
NOTE: Copper clad steel shown on drawings and standard drawings as 7 No. 5 shall be 7 No. 4, or 19 No.8, in lieu of 7 No. 5. New cable trench grounding shall be two (2) 7 No. 4, or two 19 No. 8, copper-clad steel conductors in lieu of two 2/0 AWG copper conductor as indicated in WAPA Standard 9.2.1.2 (7) as shown on Drawing 31 1061. (For clarification, 7 No. 4 is seven (7) individual number 4 conductors, stranded together to form a single conductor. Nineteen No. 8 is nineteen (19) individual No. 8 conductors, stranded together to form a single conductor.)
c. Electrical Conduit System: Electrical conduit system including embedded and exposed conduit. Conduit entering the cable trench with a 90-degree bend is allowed to be Schedule 40 PVC as shown on Drawing 31 1006. All other 90-degree bends shall be rigid metal. All underground rigid metal conduits shall have half lapped 10-mil corrosion protection tape extending 6-inches above finished grade. A red or yellow polyethylene warning tape shall be installed directly above each conduit run and located 12-inches below finished grade. All conduits shall have sealing compound installed at both ends. Informational drawings and data are not required for this item.
d. Outdoor Bus System: Outdoor strain and jumper buses, rigid buses and overhead ground wire unless otherwise specified on the Drawings, splices, elbows, pad type terminal connectors and other fittings used on rigid or cable buses shall be compression type (DMC Power’s Bus & Cable Connectors and Swage System, AFL Swage system, or equal.) If required, tools shall be obtained from respective manufacturers.
A minimum of three (3) twenty-foot lengths of 4-inch tubular aluminum bus, ten (10) swage type couplers and proper tooling shall be kept on site throughout construction for emergency bus restoration. The existing bus work shall be cut in a manner that allows adequate length for the installation of swage type couplers for emergency and final installation. Final coupler fittings shall not be installed in the middle third of the span.
e. Receptacles: Provide 120 V power receptacles within a weatherproof receptacle box as shown on the Drawings.
f. Cable Terminators: Cable terminators shall include molded rubber caps, crimp rings, non-tracking terminator housings, stress relief, ground straps, mounting brackets and lugs suitable for connecting to electrical equipment with a NEMA 2-hole pad.
g. Riser Cable Supports: Support/secure 35-kV cables at existing conduit risers with ETCO
Multiplex Duct-Loc Plugs sized according to the conduit risers and the outside diameter of the conductors referenced in item 5 above.
h. Emergency Generator Connection Box: Install Government furnished emergency generator connection box as shown on Drawing ODA 1600.
i. Equipment Identification Signs (31 1000): Lettering on the signs shall be as shown on Drawing ODA 1102.
18. Bidding Schedule item “Existing outdoor electrical equipment and material” includes constructing a temporary storage facility to hold existing equipment containing PCB oil with 2-ppm or greater. The temporary storage facility shall be in accordance with the standards. Bidding Schedule item “Existing outdoor electrical equipment and material” also includes removal and disposal of existing electrical equipment and material.
a. Material to be removed and disposed of is as follows:
(1) Pad mount transformer designated KZ31A.
(2) Unit substation designated DZA.
(3) 375KW Standby generator. Associated propane tank, curb stops and bollards.
(4) Substation control, power cables and conduit as designated on the Drawings.
Portions of cables in conduit, trench, and/or trays shall be removed and disposed of.
DIVISION 13 – ENVIRONMENTAL QUALITY PROTECTION
The Contractor shall comply with all Federal, State and local environmental laws and the requirements set forth in WAPA Construction Standard 13 – Environmental Quality Protection:
https://www.wapa.gov/DoingBusiness/SellingToWestern/Documents/ConstructionStandard2016.pdf.
Specifically, the Contractor will be required to provide the following. Final payment will be withheld until the referenced submittal, report or plan is received.
1. SUBMITTALS:
a. Spill Prevention Notification and Cleanup Plan (Plan): The Contractor will submit the Plan as described in Section 13.11.2, “Spill Prevention Notification and Cleanup Plan”, to the COR for review and comment 14-days prior to start of work. Review of the Plan is for the purpose of determining compliance with the specifications only and shall not relieve the Contractor of the responsibility for compliance with all Federal, State and local regulations.
A template plan is available by request.
b. Oil Sample Results for Oil and Oil Filled Equipment: Obtain and submit oil sampling laboratory results for PCBs 14-days prior to the start of work.
c. Waste Profiles and Manifests: The Contractor will submit a draft waste profile and a draft of manifests or other shipping papers to the COR at least two (2) business days prior to shipping of hazardous materials or hazardous wastes.
d. Permits: The Contractor will submit any required permits to the COR at least 14-days prior to the start of work. These permits include, but are not limited to:
(1) Air Permits and/or registrations for off-road or portable equipment to be utilized on the project.
(2) Air Permits, including the Authority to Construct and Permit to Operate for stationary equipment to be left on the jobsite.
The Contractor may consult with WAPA environment for assistance in preparing permit applications for equipment which will be owned by WAPA at project completion.
e. Recycled Materials Reporting: All materials generated from the project that can be recycled, will be recycled. Submit quantities of recycled materials listed in Section 13.7, “Recycled Materials Quantities” to the COR prior to submittal of final invoice. Record quantities of material by category that is salvaged, recycled, reused, or reprocessed, including:
(1) Transformers, Breakers, Other Electrical Equipment (weight without oil).
(2) Oil: Amount in Gallons.
(3) Aluminum conductor – Steel Reinforced (ACSR): Weight in pounds or tons.
(4) Steel: Weight in pounds or tons.
(5) Aluminum: Weight in pounds or tons.
(6) Copper: Weight in pounds or tons.
(7) Other Metals: Weight in pounds or tons.
(8) Gravel, Asphalt, or Concrete: Weight in pounds or tons.
(9) Batteries: Weight in pounds.
(10) Wood construction material: Weight in pounds.
(11) Cardboard: Weight in pounds.
(12) Fluorescent Bulbs: Weight in pounds.
(13) Ballasts: Weight in pounds.
(14) Refrigerants and Ozone Depleting Substances.
(15) Certificates of Recycling for any of these materials from the Recycling Facility.
f. Waste Material Reporting: Submit quantities (pounds or metric tons) of all waste materials by category to the COR within 30-days of disposal and prior to submittal of final invoice.
This information can come from weight tickets or from manifests. They should include the information requested below, including:
(1) Unregulated Wastes (i.e., trash): Volume in cubic yards or weight in pounds.
(2) Hazardous or Universal Wastes: Weight in pounds or gallons.
(3) Certificates of Disposal for any of these materials from the Disposal Facility.
2. PREVENTION OF AIR POLLUTION:
a. GENERAL: The Contractor will manage the project in accordance with the Clean Air Act and California air quality regulations. The Contractor will submit valid air permits when required as described in the submittals section. The Contractor will be familiar with the National Ambient Air Quality Standards (NAAQS) attainment status at the project location, and employees working on the site will be familiar with how attainment status affects the project. In addition, the Contractor shall fulfill the conditions of any applicable locally prepared Environmental Impact Statements (EISs) or Environmental Assessments (EAs) conducted for the project under the National Environmental Protection Act (NEPA).
b. Heavy Equipment and Emissions Provisions: If the Contractor will be bringing a temporary emissions source onto the jobsite, either as heavy equipment to support project demolition, construction, cleanup or project completion or to provide a temporary power source to support the project, the Contractor is responsible to determine whether any air quality permit or registration is required and to obtain and provide a copy of the permit or evidence of the required registration to the COR 14-days prior to the start of work. In addition, the Contractor is required to observe the operating conditions of the registrations or permits, and to observe the Sierra Nevada Region (SNR) Idling Policy, as well as the standard operating procedures for the zone they are working in.
3. WESTERN AREA POWER ADMINISTRATION, SIERRA NEVADA IDLING POLICY:
Idling of diesel equipment is limited by the idling policy below. This policy is in place to comply with the State Implementation Plan and to comply with Standard Operating Procedures agreed to in WAPA’s Environmental Assessments and Environmental Impact Statements.
a. The WAPA SNR Fleet must meet the following idling limits:
(1) Idling Limit: No vehicle or engines in the SNR fleet may idle for more than five (5) consecutive minutes. If SNR rents or leases an item of diesel equipment, compliance with this idling policy shall be the responsibility of SNR, and that will be indicated in the lease agreement.
(2) This idling limit does not apply to:
(a) Idling when queuing.
(b) Idling to verify that the vehicle is in safe operating condition.
(c) Idling for testing, servicing, repairing or diagnostic purposes.
(d) Idling necessary to accomplish work for which the vehicle was designed (such as operating a crane).
(e) Idling required to bring the machine system to operating temperature.
(f) Idling necessary to ensure safe operation of the vehicle.
(g) Idling of utility vehicles necessary in order to operate flashing lights for jobs that occur on roadways and other hazard areas.
(h) Idling of utility vehicles when necessary to avoid a safety emergency.
Operators working with high-voltage equipment must remain in constant contact with other operators of the electric grid via radio in order to avoid safety incidents. For jobs performed at night spotlights may be required. In order to ensure the safety of these operators, the engine may need to remain running beyond the regulation’s 5-minute limit.
If the project will result in the construction of a new permanent emissions source such as an emergency backup generator, the Contractor will be responsible to review the equipment specifications with local air district personnel and to determine whether any air quality permit or registration is required. In addition, the Contractor will prepare the permit application and obtain and provide a copy of the “Authority to Construct” to the COR at least 3-days prior to bringing the emissions source onto the jobsite.
This is the start of the file's text. The full file is on GovTribe.