ATTACHMENT B - S-629-0014548 Plans set 2025.08.04 - ODF Forest Grove District.pdf
PDF 5 MB Posted
- Solicitation number
- S-62900-00014548
- Issued by
- Washington County, Oregon
About this file
This document is a comprehensive design contract and construction document package for the Oregon Department of Forestry's Forest Grove District, specifically for the Warehouse and Fire Cache Cladding and Window Rehabilitation project located at 801 Gales Creek Road in Forest Grove, Oregon. The project involves a complete exterior rehabilitation of two buildings within a six-building compound, focusing on replacing 100% of existing siding, trim, windows, doors, gutters, and downspouts. The rehabilitation will be performed while the buildings remain occupied, with the intent to complete work in a single phase across each building elevation. The project will utilize the 2022 Oregon Structural Specialty Code and related specialty codes, with work concentrated on the Warehouse and Fire Cache buildings.
The project involves comprehensive replacement of exterior building components, including cedar plank lap siding, T1-11 wood panel cladding, and existing wood-framed windows and doors. Replacement materials will include fiber cement plank lap cladding, board and batten cladding, flanged vinyl windows, fiberglass swing doors, and new aluminum gutters and downspouts. The contract includes detailed specifications for installation techniques, waterproofing, flashing, sealant application, and moisture management. Specific modifications include reinstalling some existing doors, infilling a window opening with a new mechanical unit, and maintaining the existing roof while performing necessary flashing and edge repairs. The project is funded by the Oregon Department of Forestry and will be executed with careful coordination to minimize disruption to ongoing operations.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VICINITY MAP
N
PROJECT INFORMATION:
ADDRESS:
Oregon Department of Forestry Forest Grove District 801 Gales Creek Rd., Forest Grove, OR 97116
LEGAL DESCRIPTION:
4TL1 Tractland-Area 1, Acres 5.05
PERMIT No.:
TBD
PROJECT SUMMARY:
This Design Contract Document package is for Permit Issue purposes and are for project construction. Refer to sheets A0.00, A1.00 Architectural Site Plan, and to the Project Manual Summary of Work section for full project scope, basis of design, and description.
PROJECT DESIGN / ASSEMBLY GROUPS:
A0.00 COVER SHEET, GENERAL NOTES, ABBREVIATIONS &
SYMBOLS, CODE REVIEW, AND PROJECT DESCRIPTION
A0.10 SHEET SEQUENCE AND DETAIL INDEX
A1.00 SITE PLAN
A2.00 BUILDING ELEVATIONS
A3.00 WALL DETAILS
A4.00 WALL OPENING DETAILS
Aerial View - Looking Northwest
08.04.2025 - PLANS SET
Oregon Department of Forestry - Forest Grove Warehouse and Fire Cache
Cladding and Window Rehabilitation (PO-62900-00046367)
PROJECT
LOCATION
EXISTING USE AND OCCUPANCY:
1. Zoning: R-10
2. Zoning Overlay: n/a
3. Occupancy Groups: B, S, U
4. Construction Type: Type VB
5. County Seat: Washington
6. Property ID: R779802 (Included for Coordination)
7. Tax Lot ID: 1N436B004400 (Included for Coordination)
SITE AREAS AND BUILDING HEIGHTS:
1. Project Site Area: 5.05 AC. (291,987 SF) (Unchanged)
2. Number of Buildings: (6) Permanent, (1) Temp (Unchanged)
3. Total Site Building Area: (Existing) (Unchanged)
4. Number of Stories: Varies (Existing) (Unchanged)
5. Existing Building Heights: (Existing) (Unchanged)
APPLICABLE PROJECT CODES:
1. BUILDING CODES IN EFFECT AT TIME OF REHABILITATION PROJECT:
· 2022 Oregon Structural Specialty Code (O.S.S.C.) Amendments (B.O. 2021 International Building Code)
· 2021 Oregon Energy Efficiency Specialty Code (OEESC)
· 2022 Oregon Mechanical Specialty Code (B.O. 2021 IMC & International Fuel Gas Code)
· 2021 Portland Fire Code and the 2019 Oregon Fire Code
· 2021 Oregon Electrical Specialty Code (B.O. 2020 NFPA 70 - National Electrical Code)
· 2021 Oregon Plumbing Specialty Code (B.O. 2021 Uniform Plumbing Code)
REHABILITATION:
1. IT IS THE OWNER'S INTENT TO PERFORM THE REHABILITATION WITHIN THE
LIMITS OF THE WORK AREA WHILE THE BUILDINGS ARE OCCUPIED.
2. IT IS THE OWNER'S INTENT TO PERFORM A FULL REHABILITATION OF ALL
EXTERIOR WALL AREAS ALONG EACH IN SCOPE BUILDING ELEVATION AS
ONE SINGLE PHASE OF WORK. CONTRACTOR SHALL COORDINATE WITH
THE OWNER FOR SCHEDULE, PHASING, AND WORK WITHIN OCCUPIED
BUILDINGS.
3. BUILDING REHABILITATION MAY NOT OCCUR IN NUMERICAL ORDER AS
RELATED TO SITE, BUILDING IDENTIFIER OR BUILDING ADDRESSES.
4. REFER TO THE SITE PLAN AND PROJECT MANUAL FOR IN SCOPE
BUILDINGS, PROJECT NOTES, ASSUMED LIMITS OF WORK, AND FULL
SUMMARY OF WORK.
PROJECT CODE ANALYSIS: PROJECT DESCRIPTION:
1. THE OREGON DEPARTMENT OF FORESTRY: FOREST GROVE DISTRICT
CAMPUS IN FOREST GROVE OREGON IS A COMPOUND OF SIX (6) FACILITY
OPERATIONS BUILDINGS. BUILDINGS WITHIN THE COMPOUND HAVE VARIED
YEARS OF DEVELOPMENT WITH LIMITED DOCUMENTATION RELATING TO
ORIGINAL DESIGN AND CONSTRUCTION. BUILDING ENCLOSURE WORK FOR
THIS PROJECT ARE SPECIFICALLY DESIGNATED FOR THE WAREHOUSE AND
THE FIRE CACHE BUILDINGS.
2. WAREHOUSE BUILDING: ELEVATIONS ARE SIMILAR IN BUILDING COMPONENTS
AND ARE PREDOMINANTLY VARIED BY FENESTRATIONS, SIDING MATERIALS,
AND ROOF CONFIGURATION. EXISTING BUILDING ENCLOSURE COMPONENTS
ARE A COMBINATION OF CEDAR PLANK LAP SIDING, WOOD SIDING PANELS
WITH CEDAR BATTENS, AND CEDAR TRIMS. THE EXISTING BUILDING ROOF IS
A PITCHED ROOF CONFIGURATION WITH GABLES AND EXPOSED RAFTER TALE
OVERHANGS AND ARE CLAD WITH COMPOSITION ASPHALT SHINGLE ROOFING
WITH 2x WOOD GABLE END BARGE BOARDS. DOORS ARE A COMBINATION OF
SWING ENTRY, ROLL-UP STORAGE, AND TRACK HUNG "BARN" STYLE DOORS.
WINDOWS ARE ORIGINAL WOOD FRAMED PLATE GLASS ASSEMBLIES WITH
WOOD MUNTIN GRIDS AND WATER TABLES.
2.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL CONSIST
OF REMOVAL, DISPOSAL, AND REPLACEMENT 100% OF EXISTING SIDING
AND TRIM ALONG EACH BUILDING ELEVATION AND INCLUDE CONCEALED
BUILDING PAPER (AS OCCURS), AND UTILITY PENETRATIONS. REMOVAL,
DISPOSAL, AND REPLACEMENT OF ALL EXISTING WINDOW UNITS.
REMOVAL, SAFE STORAGE, AND REINSTALL OF THE EXISTING SLIDING
BARN-STYLE DOOR ON THE EAST ELEVATION. REMOVAL, DISPOSAL, AND
REPLACEMENT OF SWING DOOR UNIT ON THE NORTH ELEVATION.
REMOVAL, SAFE STORAGE, AND REINSTALLATION OF REMAINING
EXISTING SWING DOOR UNITS. FLASH IN PLACE EXISTING ROLL-UP
GARAGE-STYLE DOOR UNIT. REMOVAL, DISPOSAL, AND REPLACEMENT
OF 100% OF EXISTING GUTTERS AND DOWNSPOUTS. REMOVAL AND
REPLACEMENT OF 100% OF EXISTING GABLE ROOF OVERHANG BARGE
BOARDS. INSTALLATION OF NEW EAVE OVERHANG ROOF FASCIA
BOARDS. NOTE: EXISTING ROOFING IS NOT WITHIN THE PROJECT SCOPE
AND SHALL REQUIRE REMOVAL AND REPLACEMENT OF EXISTING
SHINGLES AS NECESSARY TO INCORPORATE ROOF TO DORMER WALL,
ROOF EDGE FASCIA BOARD, AND FLASHING COMPONENTS.
3. FIRE CACHE BUILDING: ELEVATIONS ARE SIMILAR IN ASSEMBLY
CONFIGURATIONS, AND ARE PREDOMINANTLY VARIED BY POINTS OF
ACCESS, SIDING MATERIALS, AND ROOF CONFIGURATION. BUILDING
COMPONENTS ARE A COMBINATION OF T1-11 WOOD PANEL CLADDING,
CEDAR PANEL CLADDING, CEDAR PLANK LAP SIDING WITH CEDAR TRIM AND
NARROW CEDAR PANELS WITH ANGLED CEDAR BATTENS. THE BUILDING
ROOF IS A PITCHED ROOF WITH GABLES AND OVERHANGS AND ARE CLAD IN
COMPOSITION ASPHALT SHINGLE ROOFING WITH CEDAR BARGE BOARDS.
DOORS ARE A COMBINATION OF SWING ENTRY AND ROLL-UP VEHICLE
ACCESS DOORS. WINDOWS ARE ORIGINAL WOOD FRAMED ASSEMBLIES (WITH
WOOD MULLIONS AS OCCURS).
3.1. THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL CONSIST
OF REMOVAL, DISPOSAL, AND REPLACEMENT 100% OF EXISTING SIDING
AND TRIM ALONG EACH BUILDING ELEVATION AND INCLUDE CONCEALED
BUILDING PAPER (AS OCCURS), AND UTILITY PENETRATIONS. WHERE
SINGLE-WALL CONSTRUCTION OCCURS AT EXISTING T1-11 AND CEDAR
PANELS, IF DEEMED APPROPRIATE, PANELS MAY BE USED AS WALL
SHEATHING. REMOVAL, DISPOSAL, AND REPLACEMENT OF ALL EXISTING
WINDOW UNITS AND ASSOCIATED TRIMS. AT IDENTIFIED REAR WINDOW
LOCATION (REFER TO ELEVATIONS) THE B.O.D. SHALL BE TO INFILL
WINDOW R.O. WITH NEW 2x WOOD STUD FRAMING, EXTERIOR AND
INTERIOR SHEATHING, AND INSTALLATION OF A 'NEW' THROUGH-WALL
PTAK COOLING AND HEATING UNIT. REMOVAL, SAFE STORAGE, AND
REINSTALLATION OF ALL EXISTING SWING DOOR UNITS. FLASH IN PLACE
EXISTING ROLL-UP GARAGE-STYLE DOOR UNITS. REMOVAL, DISPOSAL,
AND REPLACEMENT OF 100% OF EXISTING GUTTERS AND DOWNSPOUTS.
INSTALLATION OF NEW EAVE OVERHANG ROOF FASCIA BOARDS. NOTE:
EXISTING ROOFING IS NOT WITHIN THE PROJECT SCOPE AND SHALL
REQUIRE REMOVAL AND REPLACEMENT OF EXISTING SHINGLES AS
NECESSARY TO INCORPORATE ROOF EDGE FASCIA BOARDS AND
FLASHING COMPONENTS.
GENERAL NOTES: GENERAL NOTES, CONT.:
1. READ DESIGN DOCUMENTS (DRAWINGS) IN CONJUNCTION WITH THE
PROJECT MANUAL (PRODUCT SPECIFICATIONS).
2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON SITE.
3. DRAWINGS OF ELEVATIONS AND SITE PLANS OF THE PROJECT ARE
REPRODUCED FROM BASE DRAWINGS PREPARED BY ORIGINAL
ARCHITECT. BRING DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND
ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE
BUILDING ENVELOPE CONSULTANT AND REQUEST A REVIEW.
4. EXECUTION OF THE CONTRACT BY THE CONTRACTOR IS A
REPRESENTATION THAT THE CONTRACTOR HAS VISITED THE SITE,
BECOME GENERALLY FAMILIAR WITH THE LOCAL CONDITIONS UNDER
WHICH THE WORK IS TO BE PERFORMED AND CORRELATED PERSONAL
OBSERVATIONS WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS.
5. ALL WORK TO BE PERFORMED UNDER THIS SCOPE OF REPAIRS (WORK)
SHALL BE CONDUCTED IN FULL COMPLIANCE WITH ALL APPLICABLE
LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. IT IS THE
CONTRACTOR'S DUTY TO BE FAMILIAR WITH ALL SUCH APPLICABLE
LOCAL, STATE, AND FEDERAL LAWS AND REGULATIONS. FURTHERMORE,
THE CONTRACTOR SHALL ENSURE THAT ALL ACTIVITIES PERFORMED BY
THE CONTRACTOR'S PERSONAL EMPLOYEES, SUBCONTRACTORS, AND
SUPPLIERS COMPLY WITH THESE LAWS AND REGULATIONS DURING THE
CONSTRUCTION PROCESS.
6. CONTRACT DRAWINGS ARE COMPLIMENTARY, AND WHAT IS REQUIRED
BY ANY ONE SHALL BE BINDING AS IF REQUIRED BY ALL. BEFORE
STARTING EACH PORTION OF THE WORK, CAREFULLY STUDY AND
COMPARE THE VARIOUS DRAWINGS AND OTHER CONTRACT DOCUMENTS
RELATIVE T0 THAT PORTION OF THE WORK, AS WELL AS INFORMATION
FURNISHED BY OWNER. TAKE FIELD MEASUREMENTS OF ANY EXISTING
CONDITIONS RELATED TO THAT PORTION OF THE WORK AND OBSERVE
CONDITIONS AT THE SITE AFFECTING IT. THESE OBLIGATIONS ARE FOR
THE PURPOSE OF FACILITATING CONSTRUCTION BY THE CONTRACTOR
AND NOT FOR THE PURPOSE OF DISCOVERING ERRORS, OMISSIONS, OR
INCONSISTENCIES IN THE CONTRACT DOCUMENTS; HOWEVER, REPORT
ERRORS, OMISSIONS, OR INCONSISTENCIES DISCOVERED BY THE
CONTRACTOR PROMPTLY TO THE CONSULTANT AS A REQUEST FOR
INTERPRETATION IN THE FORM PROVIDED IN THE PROJECT MANUAL.
7. REPORT DISCREPANCIES IN CONTRACT DOCUMENTS TO FORENSIC FOR
CLARIFICATION PRIOR TO COMMENCING WORK.
8. IMMEDIATELY NOTIFY BUILDING ENVELOPE CONSULTANT UPON
DISCOVERY OF ADDITIONAL UNFORESEEN DAMAGE TO EXISTING
CONSTRUCTION SCHEDULED TO REMAIN AND THAT IS OUTSIDE THE
CONTRACT. REQUEST A REVIEW. DO NOT COMMENCE RELATED WORK
TO NEARBY WORK WITHOUT CONSULTANT APPROVAL.
9. TRADE CONTRACTORS ARE RESPONSIBLE FOR THE LAYOUT OF THEIR
OWN WORK, AND TO SEE THAT ITS WORK COMES TOGETHER WITH THAT
OF OTHERS. REPORT DISCREPANCIES ON DRAWINGS TO BUILDING
ENVELOPE CONSULTANT FOR DECISIONS.
10. TRADE CONTRACTORS MUST ASSURE THEMSELVES THAT THEY HAVE
THE LATEST DRAWINGS ISSUED FOR CONSTRUCTION, SPECIFICATIONS,
MANUFACTURERS' INSTALLATION INSTRUCTIONS AND REFERENCE
STANDARDS IN THE CONTRACTOR'S OFFICE.
11. DURING REMEDIATION WORK, THE CONTRACTOR IS TO VERIFY AND
MAINTAIN RATED WALL ASSEMBLIES AT ALL EXISTING WALL LOCATIONS.
OVERSIGHT IS REQUIRED BY A LICENSED STRUCTURAL ENGINEER TO
PROVIDE FRAMING AND SHEATHING CONDITIONS ASSESSMENT
INCLUDING RATED WALLS WHERE REPAIR WORK IS IDENTIFIED DURING
ACTUAL WORK ON THE PROJECT. THE CONTRACTOR IS TO PROVIDE
AREA SPECIFIC ENGINEERED DRAWINGS SHOWING EXTENT, DETAILS,
AND CALCULATIONS TO THE AUTHORITY HAVING JURISDICTION FOR
REVIEW AND APPROVAL PRIOR TO REMEDIATION WORK.
CONCEALED BARRIER INSTALLATION:
1. CLEAN AND PREPARE SURFACES PRIOR TO INSTALLATION OF ALL
MEMBRANES IN ACCORDANCE TO PRODUCT MANUFACTURERS'
RECOMMENDATIONS AND AS DIRECTED BY BUILDING ENCLOSURE
CONSULTANT.
2. CONTRACTOR TO PROVIDE ISOMETRIC FLEXIBLE SADDLE
FLASHINGS AT MULTI-PLANE WALL, WALL OPENING, ROOF
TRANSITION, AND DECK TRANSITION AREAS AS OCCURS AND AS
DETAILED PER DESIGN DOCUMENTS.
MEMBRANE INSTALLATION:
1. SEAL WEATHER-RESISTIVE BARRIER AT ALL LAPS AND
TERMINATIONS TO CREATE AIR BARRIER. NOT ALL SEALANT
LOCATIONS ARE ILLUSTRATED.
2. PROVIDE FURRING STRIPS/RAIN SCREEN BEHIND ALL EXTERIOR
CLADDING AND TRIM IN ACCORDANCE WITH THE DRAWINGS,
SPECIFICATIONS, AND MANUFACTURER'S WRITTEN
INSTRUCTIONS.
METAL FLASHING:
1. PROVIDE AND INSTALL METAL HEAD FLASHING WITH FOLDED,
UPTURNED END DAMS OVER WINDOW, DOOR, AND SLIDING
GLASS DOORS TRIM. CONTRACTOR TO FIELD VERIFY THAT METAL
HEAD FLASHING DOES NOT INTERFERE WITH OPERATION OF THE
FENESTRATION.
2. FORM 100% OF THROUGH-WALL AND HEAD FLASHINGS WITH A
SLOPED HORIZONTAL SURFACE CONFORMING TO THE
FOLLOWING CRITERIA:
· ENSURE A 5% SLOPE AT GREATER THAN OR EQUAL TO A
1-1/2" WIDE HORIZONTAL SURFACE
· ENSURE A 10% SLOPE AT LESS THAN A 1-1/2" WIDE
HORIZONTAL SURFACE
3. CONTRACTOR TO PROVIDE 3-DIMENSIONAL METAL SADDLE
FLASHINGS AT MULTI-PLANE SUBSTRATE INTERSECTIONS, ROOF
TRANSITIONS, WALLS TRANSITIONS, DECK TRANSITIONS, AND AT
OTHER SIMILAR LOCATIONS AS OCCURS AND AS DETAILED PER
DESIGN DOCUMENTS.
EXTERIOR OPENINGS AND PENETRATIONS:
1. ALL SCHEDULES AND QUANTITIES OF WINDOWS, DOORS, VENT
PENETRATIONS, AND EXTERIOR FIXTURES, SUCH AS LIGHT
FIXTURES, CONVENIENCE RECEPTACLES, EXHAUST VENTS, PIPE
PENETRATIONS, HOSE BIBBS, ELECTRICAL OR METERS, ETC.,
THAT HAVE BEEN PROVIDED IN THE DOCUMENTS ARE
APPROXIMATE AND MUST BE VERIFIED BY THE CONTRACTOR ON
SITE. CONTRACTOR SHALL PERFORM OWN QUANTITY SURVEY
AND VERIFIED QUANTITIES OF ALL ITEMS INDICATED IN THE
DRAWINGS.
2. SEAL EXTERIOR WALL PENETRATIONS FOR AIR BARRIER
CONTINUITY WITH SCHEDULED MINIMALLY EXPANDING FOAM
INSULATION.
3. FORM EXTERIOR PERIMETER DYNAMIC SEALANT JOINTS, 1/2"
WIDE TYPICAL, WITH CONTINUOUS CLOSED CELL BACKER ROD
U.O.N., ENSURE BACKER ROD DIAMETER EXCEEDS JOINT WIDTH
BY 25% AND MAINTAIN A JOINT WIDTH-TO-DEPTH RATIO OF 2:1.
GENERAL NOTES, CONT.:
DRAWING TERMS:
1. DEMOLISH: (DEMO) TO COMPLETELY REMOVE AND LEGALLY
DISPOSE OF OFF-SITE IN A MANNER COMPLIANT WITH FEDERAL,
STATE, AND LOCAL PROTOCOLS.
2. SCHEDULED (ITEM): COMPONENTS CALLED OUT AS SCHEDULED
SHALL REMAIN IN PLACE, BE REMOVED AND REINSTALLED, BE
REMOVED AND REPLACED, BE INSTALLED AS A NEW
COMPONENT, OR REPLACED IF DAMAGED IS DISCOVERED.
REFER TO PROJECT MANUAL FOR CONDITION, ASSEMBLIES, AND
RELATED MATERIALS.
3. PROTECT (ITEM): A TERM USED ON DRAWINGS TO INDICATE AN
ITEM REQUIRES PROTECTION FROM THE WORK.
4. REMOVE (ITEM): A TERM USED ON DRAWINGS TO INDICATE A
SPECIFIC ITEM TO BE DETACHED FROM EXISTING CONSTRUCTION
AND LEGALLY DISPOSED OF OFF-SITE, UNLESS INDICATED
OTHERWISE TO BE REMOVED, SALVAGED, AND REINSTALLED.
5. REMOVE AND REINSTALL (ITEM): A TERM USED ON DRAWINGS TO
INDICATE A SPECIFIC ITEM TO BE DETACHED FROM EXISTING
CONSTRUCTION, PREPARED FOR REUSE, AND REINSTALLED
BACK IN ITS EXISTING LOCATION.
6. RELOCATE (ITEM): A TERM USED IN DRAWINGS TO INDICATE AN
EXISTING ITEM THAT HAS BEEN REMOVED, AND TO BE
REINSTALLED IN A NEW LOCATION
7. SALVAGE (ITEM): CAREFULLY DETACH FROM EXISTING
CONSTRUCTION, IN A MANNER TO PREVENT DAMAGE READY FOR
REUSE. INCLUDE FASTENERS OR BRACKETS NEEDED FOR
REATTACHMENT IN ORIGINAL LOCATION OR ELSEWHERE.
8. EXISTING TO REMAIN (ITEM): A TERM USED ON DRAWINGS TO
INDICATE EXISTING ITEMS OF CONSTRUCTION THAT ARE NOT BE
REMOVED AND THAT ARE NOT OTHERWISE INDICATED TO BE
REMOVED, SALVAGED, OR REMOVED AND REINSTALLED.
EXISTING TO REMAIN IS INDICATED BY GRAPHIC LINETYPE
SYMBOL.
9. PHASE: A PORTION OF THE WORK TO BE COMPLETED DURING A
SET PERIOD OF TIME, AS DEFINED IN THE PROJECT
SPECIFICATIONS.
10. REFER TO SPECIFICATIONS SUMMARY OF WORK, GENERAL
DESCRIPTION OF WORK, FOR SCOPE OF REPAIR ASSEMBLIES.
ALUM. ALUMINUM
APPROX. APPROXIMATE
ARCH. ARCHITECTURAL
BLDG. BUILDING
BOT BOTTOM
COL. COLUMN
CONC. CONCRETE
CONT. CONTINUOUS
CONST. CONSTRUCTION
C/W COMPLETE WITH
DIA. DIAMETER
DEFS DIRECT-APPLIED
FINISH SYSTEM
DIM. DIMENSION
DWG DRAWING
DS DOWNSPOUT
E. EAST
EA. EACH
ELEV. ELEVATION
ELEC. ELECTRICAL
EIFS EXTERIOR INSULATION &
FINISH SYSTEM
EQ. EQUAL
EQUIP. EQUIPMENT
EXIST. EXISTING
EXT. EXTERIOR
FC FIBER CEMENT
FIN. FINISH
ABBREVIATIONS:
F.O.S. FACE OF STUD
FLR. FLOOR
FRTW FIRE-RETARDANT
TREATED WOOD
FURR FURRING OR FURRED
GA GAUGE
GALV. GALVANIZED
GWB GYPSUM WALL BOARD
GYP. GYPSUM
HORIZ. HORIZONTAL
INT. INTERIOR
INSUL. INSULATION
MAX MAXIMUM
MEMB. MEMBRANE
MTL METAL
MIN. MINIMUM
MISC. MISCELLANEOUS
N. NORTH
N.I.C. NOT IN CONTRACT
(NOT IN SCOPE)
NTS NOT TO SCALE
O.C. ON CENTER
PLY PLYWOOD
P.T. PRESSURE TREATED (POST-TENSIONED
WHEN USED WITH CONCRETE)
R RADIUS
REF. REFERENCE
REINF REINFORCED
REQ'D REQUIRED
RD ROOF DRAIN
S. SOUTH
SAM SELF ADHESIVE
MEMBRANE (FLASHING)
SECT. SECTION
SIM. SIMILAR
SPEC SPECIFICATION
S.S. STAINLESS STEEL
STRUCT. STRUCTURAL
T&G TONGUE AND GROOVE
TBD TO BE DETERMINED
TEMP TEMPERATURE
T.O.W. TOP OF WALL
TYP. TYPICAL
U.O.N. UNLESS OTHERWISE NOTED
VERT. VERTICAL
V.I.F. VERIFY IN FIELD
W. WEST
W/ WITH
W/O WITHOUT
WRB WEATHER-RESISTIVE
BARRIER
GYPSUM SHEATHING / GYPSUM WALLBOARD
BATT INSULATION
DETAIL HATCH PATTERN LEGEND:
TYPICAL LINE WEIGHT OF 'NEW' BUILDING ENVELOPE
COMPONENTS - WALLS, WINDOWS, DOORS, ETC.
SAM - SELF APPLIED MEMBRANE FLEXIBLE FLASHING,
OR MANUFACTURED FLASHING PANELS AS NOTED
WRB - WEATHER RESISTIVE BARRIER
MISC. COMPONENTS - DRAINAGE MAT, REINFORCING
MESH, BUG SCREEN, FASTENERS, SCREWS, NAILS
EXISTING ROOF UNDERLAYMENT, OTHER EXISTING
COMPONENTS
METAL FLASHING
SEALANT / ADHESIVE LAYER
LINETYPE LEGEND:
FIBER CEMENT CLADDING / CEMENT
BOARD / TILE ADHESIVE
CONCRETE
DECK COATING REINFORCEMENT MESH
DRAINAGE MAT
ACRYLIC REINFORCED CEMENTITIOUS DECK
COATING SYSTEM
POLYURETHANE DECK COATING / CONCRETE
DAMP-PROOFING
RIGID INSULATION / FOAM
STEEL / METAL
SCHEDULED WRB
SCHEDULED SAM
METAL FLASHING, COPING, AND SADDLES
APPLIED DECK COATING SYSTEM
SCHEDULED SEALANT
ISOMETRIC DETAIL HATCH PATTERN LEGEND:
TYPICAL LINE WEIGHT OF EXISTING BUILDING
ENVELOPE COMPONENTS
DYNAMIC SEALANT JOINT: SEALANT APPLIED OVER
CLOSED CELL BACKER ROD (2:1 RATIO)
CONTINUOUS SEALANT BEAD
PLYWOOD SHEATHING
PROJECT TEAM:
Warehouse Building Side/Front Elevation - Looking Northwest
PROJECT PARAMETERS:
1. UNLESS ACCOMPANIED BY DOCUMENTATION STAMPED BY A LICENSED
PROFESSIONAL, THE WORK DESCRIBED WITHIN THESE CONTRACT
DOCUMENTS SHALL NOT INCLUDE THE FOLLOWING CRITERIA (REFER TO
ORS 671.030d):
· THE STRUCTURAL PART OF THE BUILDING, INCLUDING BUT NOT
LIMITED TO THE FOUNDATION WALLS, FLOORS, ROOF, FOOTINGS,
BEARING PARTITIONS, BEAMS, COLUMNS AND JOISTS, IS NOT
INVOLVED;
· THE BUILDING CODE CLASSIFICATION BY USE OR OCCUPANCY OF
THE BUILDING IS NOT CHANGED; AND
· THE BUILDING CODE CLASSIFICATION BY TYPE OF CONSTRUCTION
OF THE BUILDING IS NOT CHANGED.
2. NON-STRUCTURAL WORK DESCRIBED WITHIN THESE CONTRACT
DOCUMENTS SHALL FALL UNDER EXCEPTIONS: 2 OF OSSC 107.1IN THAT
PLANS, SPECIFICATIONS, CALCULATIONS, DIAGRAMS AND OTHER DATA
PREPARED AND DESIGNED BY AN ENGINEER OR ARCHITECT LICENSED
BY THE STATE TO PRACTICE AS SUCH ARE NOT REQUIRED FOR THE
FOLLOWING WORK:
· 2.3 ALTERATIONS OR REPAIRS THAT DO NOT INVOLVE THE
STRUCTURAL PARTS OF THE BUILDING.
3. IT IS RECOGNIZED THAT THERE MAY BE SEPARATE TRADE PERMITS
RELATED TO PLUMBING OR UTILITY EXTENSIONS AND/OR MINOR
RECONFIGURATIONS OF EXTERIOR VENTILATION AND ELECTRICAL
PENETRATIONS RELATED TO THIS REHABILITATION PROJECT. IT IS
UNLIKELY THAT MECHANICAL AND/OR FIRE LIFE SAFETY SYSTEMS
INCLUDING ALARMS OR FIRE SPRINKLER SYSTEMS WILL BE AFFECTED.
CLIENT:
Oregon Department of Forestry 2600 State Street Salem, OR 97310 Contact: Joseph Pfau Phone: 503.507.1527 email: joseph.j.pfau@odf.oregon.gov
BUILDING ENVELOPE CONSULTANT:
Forensic Building Consultants 12901 SE 97th Ave., Suite 310 Clackamas, OR 97015 Phone: 503.772.1114 Contact: Jordon Wyatt, Project Manager email: jordon@forensicbuilding.com
Michael Green, Technical Design Manager email: michaelg@forensicbuilding.com
AUTHORITY HAVING JURISDICTION:
Washington County Building Services 155 N First Avenue, Hillsboro, OR 97124 Development Review/Planning: 503.846.8761 Inspections: 503.846.3699 email: lutbldg@washingtoncountyor.gov www.washingtoncountyor.gov/
Fire Cache Building Side/Rear Elevation - Looking West Warehouse Building Front Elevation - Looking West
CONTRACTOR:
801 Gales Creek Rd., Forest Grove, OR 97116
PROJECT BASIS OF DESIGN
1. PROJECT BASE BID SCOPE OF REPAIR WORK COMPONENTS TO INCLUDE
THE FOLLOWING AREAS OF WORK:
· REMOVE AND DISPOSE OF CEDAR PLANK, T1-11, PLYWOOD
WALL PANEL CLADDING, WOOD BATTENS, AND TRIM
COMPONENTS
· REMOVE AND DISPOSE OF WOOD WINDOW ASSEMBLIES
· REMOVE AND STORAGE OF SELECT SWING DOOR ASSEMBLIES
· REMOVE AND DISPOSE IDENTIFIED SWING DOOR ASSEMBLY
· REMOVE AND STORAGE OF BARN-STYLE SLIDING DOOR
· ISOLATION AND PROTECTION OF ROLL UP DOOR ASSEMBLIES
· REMOVE AND DISPOSE OF GUTTERS AND DOWNSPOUTS
· REMOVE AND DISPOSE OF GABLE ROOF BARGE BOARDS
2. SCHEDULED PROJECT COMPONENTS INCLUDE, BUT ARE NOT LIMITED TO:
· WOOD FRAMING AND FURRING MEMBERS
· BATT, FOAM, AND CELLULOSE INSULATION (TO MATCH
EXISTING)
· PLYWOOD SHEATHING
· CODE COMPLIANT WEATHER-RESISTIVE BARRIER (WRB)
AND FLEXIBLE SAM FLASHING
· FIBER CEMENT PLANK LAP CLADDING, BOARD AND BATTEN
CLADDING, TRIM MEMBERS, AND MOUNTING BLOCKS
· FLANGED VINYL WINDOW UNIT(S)
· FIBERGLASS SWING DOOR UNIT(S)
· ROOF OVERHANG BARGE BOARDS AND FASCIA BOARDS
· ALUMINUM K-6 STYLE GUTTERS AND DOWNSPOUTS
· METAL THROUGH-WALL, TRANSITION, DIVERTER, AND
THREE-DIMENSIONAL METAL SADDLE FLASHINGS
· PACKAGE TERMINAL MECHANICAL UNIT (HVAC)
· SCHEDULED SEALANTS
· EXTERIOR PAINTING
Fire Cache Building Front Elevation - Looking North
A0.00
COVER SHEET
CODE ANALYSIS
PROJECT DESCRIPTION
08.04.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-095
Permit Issue Set
O re go n
D ep ar tm en t o f F or es try
Fo re st G ro ve
W ar eh ou se a nd F ire C ac he
C la dd in g an d W in do w R ep la ce m en t (
P O
-6
-0
7)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
G al es C re ek
R d.
, F or es t G ro ve
, O R
NEW ISSUE REVISED ISSUE ISSUED W/NO CHANGES NOT ISSUED AS PART OF S.O.W.*
DE
TA
IL
N O.
SH
EE
T N
O.
SHEET SEQUENCE AND DETAIL INDEX Pe rm it I ss ue S et:
.04 .20
GENERAL
A0.00 COVER SHEET, GENERAL NOTES, PROJECT AND CODE ANALYSIS
A0.10 SHEET SEQUENCE AND DETAIL INDEX
A1.00 PLAN SHEETS
1 A1.00 SITE PLAN
A2.00 REFERENCE ELEVATIONS
1 A2.01 WAREHOUSE BUILDING 'B' FRONT ELEVATION - ORIENTED FACING EAST
2 A2.01 WAREHOUSE BUILDING 'B' SIDE ELEVATION - ORIENTED FACING SOUTH
1 A2.02 WAREHOUSE BUILDING 'B' REAR ELEVATION - ORIENTED FACING WEST
2 A2.02 WAREHOUSE BUILDING 'B' SIDE ELEVATION - ORIENTED FACING NORTH
1 A2.03 FIRE CACHE BUILDING 'E' FRONT ELEVATION - ORIENTED FACING SOUTH
2 A2.03 FIRE CACHE BUILDING 'E' SIDE ELEVATION - ORIENTED FACING WEST
1 A2.04 FIRE CACHE BUILDING 'E' REAR ELEVATION - ORIENTED FACING NORTH
2 A2.04 FIRE CACHE BUILDING 'E' SIDE ELEVATION - ORIENTED FACING EAST
3.00 WALL DETAILS
1 A3.01 TYPICAL THRU-WALL FLASHING PROFILE AND LAP ISOMETRIC DETAIL
2 A3.01 TYPICAL FIBER CEMENT PLANK CLADDING BLIND / FACE NAIL LAP
AND FASTENING DETAIL
3 A3.01 TYPICAL CLADDING FASTENER INSTALLATION
4 A3.01 TYPICAL SEALANT JOINT CONFIGURATION AND APPLICATION
5 A3.01 TYPICAL BASE OF WALL ASSEMBLY AT FIBER CEMENT PLANK LAP
CLADDING - ISOMETRIC DETAIL
6 A3.01 TYPICAL SEALANT INSTALLATION AT EXTERIOR PANEL CLADDING,
TRIM, AND MOUNTING BLOCK COMPONENTS
7 A3.01 TYPICAL SEALANT INSTALLATION AT EXTERIOR PLANK LAP
CLADDING, TRIM, AND MOUNTING BLOCK COMPONENTS
8 A3.01 OUTSIDE CORNER JOINT CONDITION WITH FIBER CEMENT CLADDING
OVER RAINSCREEN CAVITY
9 A3.01 GRADE BASE OF WALL FLASHING WITH CLEARANCE AT FIBER
CEMENT PLANK LAP CLADDING
10 A3.01 DOWNSPOUT CLEANOUT COMPONENT ASSEMBLY AT GRADE WITH
FIBER CEMENT PLANK LAP CLADDING
1 A3.02 BASE OF WALL FLASHING INTEGRATION AT KERF CUT CONCRETE
SLAB WITH FIBER CEMENT PLANK LAP CLADDING
2 A3.02 FRAMED FLOOR BASE OF WALL FLASHING WITH CLEARANCE AT
FIBER CEMENT PLANK CLADDING OVER RAINSCREEN CAVITY
3 A3.02 FRAMED FLOOR BASE OF WALL FLASHING WITH KERF CUT
CONCRETE ENTRY SLAB AND FIBER CEMENT PLANK LAP CLADDING
4 A3.02 VERTICAL TRANSITION JOINT AT FIBER CEMENT CLADDING TO
EXPOSED CONCRETE - PLAN VIEW
5 A3.02 HORIZONTAL PANEL JOINT TRANSITION WITH FIBER CEMENT PANEL
CLADDING AT GABLE WALL LOCATIONS
6 A3.02 UPPER GABLE WALL TRIM BAND CLADDING TRANSITION AT FIBER
CEMENT PLANK LAP TO PANEL CLADDING
7 A3.02 TYPICAL BELLY-BAND TRIM FLASHING AT FIBER CEMENT PANEL
CLADDING - ISOMETRIC DETAIL
8 A3.02 EXHAUST VENT PENETRATION WITH MOUNTING BLOCK AT FIBER
CEMENT PLANK LAP CLADDING
1 A3.03 TYPICAL MOUNTING BLOCK INSTALLATION AT FIBER CEMENT PLANK
LAP CLADDING - ISOMETRIC SEQUENCE
3 A3.03 GABLE WALL LIGHT FIXTURE MOUNTING BLOCK INSTALL WITH FIBER
CEMENT PANEL CLADDING
4 A3.03 THROUGH-WALL PIPE PENETRATION WITH MOUNTING BLOCK AT
FIBER CEMENT PLANK LAP CLADDING
5 A3.03 SURFACE MOUNTED ELECTRICAL BOX AT FIBER CEMENT PLANK LAP
CLADDING
6 A3.03 RECESSED FIXTURE / J-BOX WITH MOUNTING BLOCK AT FIBER
CEMENT PLANK LAP CLADDING
7 A3.03 UTILITY MOUNTING BLOCK WITH PROPER DATA CABLE PENETRATION
AT FIBER CEMENT PLANK LAP CLADDING
8 A3.03 NON-PENETRATING MOUNTING BLOCK AT FIBER CEMENT PLANK LAP
CLADDING
1 A3.04 WIDE MOUNTING BLOCK INSTALL WITH FIBER CEMENT PLANK LAP CLADDING
2 A3.04 MOUNTED METER BASE HEAD AND JAMB AT FIBER CEMENT
MOUNTING BLOCK AND PLANK LAP CLADDING
4 A3.04 METER BASE GANGED CONDUIT FLASHING AT FIBER CEMENT PLANK
LAP CLADDING - PLAN VIEW
5 A3.04 METER BASE CONDUIT FLASHING AT FIBER CEMENT PLANK LAP
CLADDING - PLAN VIEW
6 A3.04 PACKAGED TERMINAL MECHANICAL UNIT WALL SECTION WITH FIBER
CEMENT TRIM AND PLANK LAP CLADDING
7 A3.04 PACKAGED TERMINAL MECHANICAL UNIT JAMB ASSEMBLY WITH
FIBER CEMENT PLANK LAP CLADDING AND TRIM
8 A3.04 GABLE WALL ANTENNA / METEOROLOGICAL EQUIPMENT MOUNT AT
FIBER CEMENT PLANK LAP CLADDING
SHEET SEQUENCE AND DETAIL INDEX
DE
TA
IL
N
O.
SH
EE
T N
O.
SHEET SEQUENCE AND DETAIL INDEX IS
SU
E
DA
TE
IS
SU
E
DA
TE
DE
TA
IL
N
O.
SH
EE
T N
O.
SHEET SEQUENCE AND DETAIL INDEX Pe rm it I ss ue S et:
.04 .20
IS
SU
E
DA
TE
A3.00 WALL DETAILS CONTINUED
1 A3.05 TOP OF WALL AT EAVE OVERHANG WITH FIBER CEMENT PLANK LAP
CLADDING
2 A3.05 TOP OF WALL TO GABLE/RAKE FASCIA WITH FIBER CEMENT PANEL
CLADDING
3 A3.05 ROOF TO DORMER WALL STEP FLASHING TRANSITION AT FIBER
CEMENT PLANK LAP CLADDING
4 A3.05 ROOF TO WALL APRON FLASHING TRANSITION AT FIBER CEMENT
PLANK LAP CLADDING
5 A3.05 APRON TO STEP FLASHING TRANSITION - ISOMETRIC DETAIL
6 A3.05 TYPICAL DIVERTER AT EXTERIOR WALL OUTSIDE ROOF CORNER
CONDITION - ISOMETRIC SEQUENCE
1 A3.06 PACKAGED TERMINAL MECHANICAL UNIT COMPONENT ASSEMBLY -
INSTALLATION ISOMETRIC SEQUENCE
A4.00 WALL OPENING DETAILS
1 A4.01 WINDOW HEAD AND SILL PAN FLASHING - INSTALL LOCATIONS
3 A4.01 TYPICAL WINDOW HEAD - CONCEALED COMPONENTS - INSTALLATION
LOCATION
4 A4.01 TYPICAL WINDOW HEAD - TRIM AND PLANK LAP CLADDING
COMPONENTS - INSTALL CONDITION
5 A4.01 TYPICAL WINDOW HEAD - TRIM AND PANEL CLADDING - INSTALLATION
CONDITION
6 A4.01 WINDOW HEAD CLADDING JOINT AT FIBER CEMENT PLANK LAP
CLADDING - INSTALL CONDITION - ISOMETRIC DETAIL
7 A4.01 WINDOW HEAD CLADDING JOINT AT FIBER CEMENT PANEL CLADDING -
INSTALL CONDITION - ISOMETRIC DETAIL
1 A4.02 TYPICAL WINDOW JAMB - CONCEALED COMPONENTS - INSTALL
CONDITION
2 A4.02 TYPICAL WINDOW JAMB TRIM AND CLADDING COMPONENTS -
INSTALL CONDITION
3 A4.02 TYPICAL WINDOW SILL - CONCEALED COMPONENTS - INSTALL
CONDITION
4 A4.02 TYPICAL WINDOW SILL - TRIM AND PLANK LAP CLADDING
COMPONENTS - INSTALL CONDITION
5 A4.02 TYPICAL WINDOW SILL - TRIM AND PANEL CLADDING COMPONENTS -
INSTALL CONDITION
6 A4.02 SWING DOOR HEAD DETAIL - TRIM AND CLADDING
7 A4.02 SWING DOOR JAMB DETAIL - TRIM AND CLADDING
8 A4.02 ENTRY SWING DOOR SILL AT STEPPED STOOP WITH ADJACENT
WALKWAY SLAB
1 A4.03 FRAMED FLOOR ENTRY SWING DOOR WITH KERF CUT CONCRETE
ENTRY SLAB
2 A4.03 ROLL UP GARAGE DOOR HEAD FLASHING WITH WOOD AND FIBER
CEMENT TRIM AND CLADDING
3 A4.03 ROLL UP GARAGE DOOR JAMB WITH WOOD AND FIBER CEMENT TRIM
AND CLADDING
1 A4.04 TYPICAL VINYL WINDOW INSTALL - ISOMETRIC SEQUENCE
1 A4.05 SWING DOOR INSTALL AT CONCRETE SLAB - ISOMETRIC SEQUENCE
DE
TA
IL
N
O.
SH
EE
T N
O.
SHEET SEQUENCE AND DETAIL INDEX IS
SU
E
DA
TE
IS
SU
E
DA
TE
A0.01
SHEET SEQUENCE
AND DETAIL INDEX
08.04.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-095
Permit Issue Set
O re go n
D ep ar tm en t o f F or es try
Fo re st G ro ve
W ar eh ou se a nd F ire C ac he
C la dd in g an d W in do w R ep la ce m en t (
P O
-6
-0
7)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
G al es C re ek
R d.
, F or es t G ro ve
, O R
1 SITE PLAN
1" = 60'-0" Oregon Department of Forestry - Forest Grove mhg
SITE AREAS AND INFORMATION:
1. Total Site Area: 5.05 AC. (291,987 SF)
2. County Seat: Washington
3. Zoning: R-10
6. Property ID: R779802 (Included for Coordination)
7. Tax Lot: 1N436B004400 (Included for Coordination)
SITE KEY NOTES:
EXISTING GRAVEL DRIVE/APRON/PARKING AREA: NOT IN PROJECT SCOPE
EXISTING CONCRETE PROPERTY ACCESS/DRIVES, ASPHALT PAVING, APRONS, WALKWAYS, AND FLATWORK AREAS: NOT IN
PROJECT SCOPE.
ALTERATION OF EXISTING UNIMPROVED/LANDSCAPED AREAS, VEGETATION, AND SITE TREES ARE NOT WITHIN THE SCOPE
OF THE PROPOSED REHABILITATION PROJECT.
THE PROPOSED BUILDING ENCLOSURE REHABILITATION SHALL BE CONSIDERED 'LIKE FOR LIKE' IN GENERAL APPEARANCE AND INCLUDE WORK TO CLADDING, ROOFING, AND FENESTRATIONS AS DESIGNATED ON SHEET A0.00.
SITE LEGEND:
APPROXIMATE LOCATIONS OF EXISTING 'MAJOR' SITE TREES.
LIMITS OF PROPOSED WORK, REFER TO SHEET A0.00 PROJECT DESCRIPTION AND SCOPE.
BUILDING LEGEND:
EXISTING DISTRICT OFFICE BUILDING - NOT IN SCOPE
EXISTING WAREHOUSE BUILDING - PROJECT BASE SCOPE
EXISTING AUTO SHOP BUILDING - NOT IN SCOPE
EXISTING HEAVY EQUIPMENT SHOP/TIRE SHOP BUILDING - NOT IN SCOPE
EXISTING FIRE CACHE AND CREW QUARTERS BUILDING - PROJECT BASE SCOPE
EXISTING LOWER BAYS BUILDING - NOT IN SCOPE
EXISTING AREA OFFICE BUILDING - NOT IN SCOPE
EXISTING "MORGUE" (TEMPORARY CHEMICAL STORAGE) - NOT IN SCOPE
EXISTING HOUSE 4 - NOT IN SCOPE
EXISTING TREE COOLER - NOT IN SCOPE
A
B
C
D
E
F
G
N
GALES CREEK ROAD
WATERCREST ROAD
BU
TT
E
D R
IV
E
VISTA D
R
IVE
MEADOW VIEW DRIVE
K N
O X
ID
G
T
R R
A C
E
ROXE DRIVE
S
TR
A S
S B
U
G
D
IV
E
INDIGO WAY
SKY LANE
ADJACENT
LOT
(N.I.C.)
ADJACENT
LOT
(N.I.C.)
ADJACENT
LOT
(N.I.C.)
ADJACENT
LOT
(N.I.C.)
ADJACENT
LOT
(N.I.C.)
ADJACENT
LOT
(N.I.C.)
ADJACENT
LOT 4100
(N.I.C.)
ADJACENT
LOTS
(N.I.C.)
ADJACENT
LOTS
(N.I.C.)
ADJACENT
LOTS
(N.I.C.)
ADJACENT
LOTS
(N.I.C.)
CORRESPONDING
LOT 4300 4.30 AC.
(N.I.C.)
302.42' M/L
300.00'
8.
M /L
0.
5.
ADJACENT
LOT 4201
(N.I.C.)
GENERAL SITE NOTES:
1. CONTRACTOR SHALL VISIT THE SITE TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS TO BETTER UNDERSTAND THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. VERIFY ALL DIMENSIONS, ELEVATIONS AND CONDITIONS PRIOR TO BEGINNING ANY
WORK AND NOTIFY FORENSIC OF ANY DISCREPANCIES. DO NOT SCALE DRAWINGS.
2. SITE PLAN ARE CREATED USING INFORMATION REPRODUCED FROM BASE DRAWINGS ACQUIRED FROM PUBLIC RECORD, AND/OR PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND
REQUEST A REVIEW.
3. BUILDINGS OR AREAS DESIGNATED AS NOT IN CONTRACT (N.I.C.) ARE OUTSIDE OF THE LIMITS AND SCOPE OF THE PROPOSED WORK.
N.I.C. BUILDINGS MAY BE ANCILLARY OR NOT BE DIRECTLY ASSOCIATED WITH THE PROJECT PROPERTY AT ALL. N.I.C. DESIGNATED BUILDINGS AND AREAS ARE INCLUDED FOR SITUATIONAL REFERENCE TO THE BOUNDARIES OF THE PROJECT ONLY.
4. UNLESS OTHERWISE INDICATED ON THESE DRAWINGS OR IN THE PROJECT MANUAL AS BEING N.I.C. OR EXISTING, ALL ITEMS, MATERIALS, ETC. AND INSTALLATION OF THE SAME ARE PART OF THE CONTRACT DEFINED BY THESE DRAWINGS AND
SPECIFICATIONS.
5. AT EXISTING EXTERIOR BUILDING WALL ASSEMBLIES, THE CONTRACTOR IS TO VERIFY AND MAINTAIN, OR REPLACE EXISTING ASSEMBLIES AS NECESSARY TO MEET RATED WALL REQUIREMENTS. OVERSIGHT REQUIRED BY A LICENSED STRUCTURAL ENGINEER TO BE PROVIDED FOR FRAMING AND SHEATHING INCLUDING RATED WALL ASSEMBLIES WHERE REPAIR WORK IS IDENTIFIED DURING CONSTRUCTION. PROVIDE ENGINEERED DRAWINGS SHOWING EXTENT, DETAILS, AND CALCULATIONS TO THE AUTHORITY HAVING
JURISDICTION FOR REVIEW AND APPROVAL PRIOR TO REMEDIATION.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING AND PAYING FOR ALL PERMITS, LICENSES, INSPECTIONS AND TESTING AS
REQUIRED BY THE CONTRACT DOCUMENTS OR ANY GOVERNMENT AGENCY.
7. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOBSITE CONDITIONS. COMPLY WITH SAFETY REGULATIONS AND RESTRICTIONS AS REQUIRED FOR WORKER AND PEDESTRIAN PROTECTION DURING THE COURSE OF CONSTRUCTION OF THIS PROJECT. PROVIDE PROTECTION AS REQUIRED TO PREVENT ANY DAMAGE TO EXISTING CONSTRUCTION WITHIN AND ADJACENT TO THE JOBSITE. WHERE DAMAGE OCCURS, REPAIR OR REPLACE DAMAGED AREA AND/OR MATERIAL AS REQUIRED TO THE OWNER'S APPROVAL AT NO ADDITIONAL COST. THESE REQUIREMENTS SHALL APPLY CONTINUOUSLY AND NOT BE
LIMITED TO NORMAL HOURS.
8. SHOULD ANY CONCRETE REQUIRE PATCHING ADJACENT TO IN SCOPE BUILDINGS, IT SHALL BE OF THE SAME SECTION AND DRAINAGE
PROFILE AS THE ADJACENT PAVED AREAS.
9. REFER TO UTILITY PENETRATION DETAILS AND TO SERVICE PROVIDER FOR COORDINATION OF MOUNTING BLOCK INSTALL, JUNCTION BOX LOCATIONS, AND CONDUIT ROUTING. THE CONTRACTOR SHALL COORDINATE THE CONNECTION OF THE EXISTING SERVICE
PROVIDER TO SCHEDULED INSTALLED COMPONENTS.
10. OWNER SHALL COORDINATE TRIMMING BACK OF LANDSCAPING AND TREES AS REQUIRED TO ALLOW ACCESS OF EXTERIOR
CLADDINGS AT THE EXISTING BUILDINGS WITHIN THE PROJECT SCOPE.
11. WHERE EXISTING GRADE ENCROACHES ON THE CLADDING, THE FINISH GRADE SHALL BE MODIFIED AND CORRECTED PER THE DESIGN DOCUMENT DETAILS AND ASSOCIATED CIVIL SCOPE FOR ALL BUILDINGS ON THE PROPERTY. IF A 6" MINIMUM DISTANCE IS NOT REASONABLY ATTAINABLE, FINISH GRADE AT THE BASE OF WALL SHALL BE MODIFIED AND RE-SLOPED AWAY FROM THE BUILDING (AT A 10-15 DEGREE SLOPE) SO AS THE BEST POSSIBLE CLEARANCE IS ACHIEVED. ADDITIONALLY, THE INCLUSION OF A CONTINUOUS 12" WIDE BY 12" DEEP GRAVEL FILLED FURROW SHALL BE INSTALLED 18" - 24" FROM THE BASE OF WALL RUNNING THE LENGTH OF THE NON-CONFORMING AREA. NOTE: GRAVEL SHALL EITHER BE 3/4" ROUND OR 3/4" MINUS CLEAN OPEN FACE CRUSHED ROCK.
A
B
E
C
D
F
G
± 28'-6"±
'-0
± 35'-4"
'-0
H
I
J
J
I
H
801 Gales Creek Rd., Forest Grove, OR 97116
(LOT 4400 5.05 AC.)
A1.00
SITE PLAN
08.04.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-095
Permit Issue Set
O re go n
D ep ar tm en t o f F or es try
Fo re st G ro ve
W ar eh ou se a nd F ire C ac he
C la dd in g an d W in do w R ep la ce m en t (
P O
-6
-0
7)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
G al es C re ek
R d.
, F or es t G ro ve
, O R
EXISTING CONCRETE FOUNDATION WALLS, ENTRY PORCHES, AND WALKWAYS TO REMAIN, REFER TO BASE OF WALL DETAILS FOR
INTEGRATION OF WRB AND FLASHING PROVISIONS.
ELEVATION KEYNOTES:
EXISTING CEDAR LAP SIDING AND TRIM TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FIBER CEMENT PLANK LAP CLADDING AND TRIM INSTALLED OVER PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT
HORIZONTAL TERMINATIONS, REFER TO WALL DETAILS AND PROJECT MANUAL.
REMOVE, LEGALLY DISPOSE OF, AND REPLACE 100% OF EXISTING GUTTER AND DOWNSPOUT ASSEMBLIES AT EXISTING LOCATIONS, REFER TO PROJECT DESIGN DOCUMENTS AND PROJECT MANUAL.
IDENTIFIED LOCATION OF EXISTING UTILITY SERVICE CONNECTIONS. REFER TO WALL DETAILS.
1 WAREHOUSE BUILDING 'B' FRONT ELEVATION
1/4" = 1'-0" ORIENTED FACING EAST
mhg
2 WAREHOUSE BUILDING 'B' SIDE ELEVATION
1/4" = 1'-0" ORIENTED FACING SOUTH
mhg
ELEVATION NOTES:
1. ELEVATIONS ARE PRODUCED USING INFORMATION ACQUIRED FROM PUBLIC RECORD, LIMITED SITE OBSERVATIONS, OWNER FURBISHED DATA, AND/OR DOCUMENTS PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND REQUEST A REVIEW. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO NOTICE TO PROCEED FROM OWNER, PRODUCT OR MATERIALS TAKE-OFFS, PRODUCT OR MATERIALS PROCUREMENT, OR FABRICATOR SHOP-DRAWING PRODUCTIONS.
2. COORDINATE DEMOLITION WITH EXTERIOR CLADDING AND WINDOW REPLACEMENT PER THE DESIGN DOCUMENTS.
PERFORM SELECTIVE AND LIMITED DEMOLITION OF EXISTING EXTERIOR SHEATHING AND ROOFING AS REQUIRED.
3. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF
SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.
4. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH
PLANE OF EXISTING ADJACENT SURFACES.
NOT USED
EXISTING ROLL-UP DOOR UNITS, INCLUDING ADJACENT TRIM AND CONCEALED COMPONENTS TO REMAIN IN PLACE WITH R.O. TRIM AND WEATHER BARRIER COMPONENTS TO BE REMOVED A ND REPLACED. INSTALL RELATED SAM WRAP FLASHING, METAL HEAD FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED SEALANT JOINTS AT FIBER CEMENT TRIM ALONG DOOR JAMBS.
REFER TO WALL OPENING DETAILS, AND PROJECT MANUAL.
11 EXISTING "BARN-STYLE" DOOR UNIT TO REMAIN. DEPENDING ON ATTACHMENT, EITHER PROTECT IN PLACE OR REMOVE, SAFELY STORE, AND REINSTALL. EXISTING ADJACENT TRIM AND CONCEALED R.O. COMPONENTS TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL R.O. SAM WRAP FLASHING, METAL HEAD FLASHING, AND RELATED CONCEALED COMPONENTS. INSTALL SCHEDULED SEALANT JOINTS AND FIBER CEMENT TRIM ALONG DOOR PERIMETERS. SILL PAN, SILL FLASHING, AND THRESHOLD TO BE OMITTED AT THIS DOOR LOCATION. INSTALL APPROPRIATE WEATHER STRIPPING DOOR SILL SEAL. EXISTING LATCH AND LOCK SET TO BE REMOVED AND REPLACED WITH NEW HEAVY DUTY HARDWARE, COORDINATE WITH OWNER. REFER TO WALL OPENING DETAILS AND PROJECT MANUAL.
EXISTING WINDOW UNITS, INCLUDING ADJACENT TRIM (AS OCCURS) AND CONCEALED COMPONENTS TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FLANGED VINYL WINDOW UNIT, INCLUDING RELATED SAM PRE AND POST WRAP FLASHING, METAL HEAD FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM ALONG 100% OF WINDOW PERIMETERS. REFER TO WALL OPENING DETAILS AND PROJECT MANUAL.
EXISTING ENTRY SWING DOOR UNITS, INCLUDING ADJACENT TRIM AND CONCEALED COMPONENTS TO BE REMOVED, SAFELY STORED, AND REINSTALLED. REINSTALL DOOR UNITS WITH RELATED SAM PRE AND POST WRAP FLASHING, METAL HEAD AND SILL PAN FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM ALONG DOOR HEAD AND JAMB PERIMETERS. REFER TO WALL OPENING DETAILS, AND PROJECT MANUAL.
EXISTING VERTICAL CEDAR PANEL SIDING, BATTENS, AND TRIM TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FIBER CEMENT PANEL CLADDING, BATTENS, AND TRIM INSTALLED OVER PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT HORIZONTAL TERMINATIONS, MATCH EXISTING BATTEN LOCATIONS. REFER TO WALL DETAILS AND PROJECT
MANUAL.
ANTENNA/METEORLOGICAL EQUIPMENT ATTACHMENT, REFER TO DETAIL 6/A3.05.15
NOT USED.
EXISTING COMPOSITION ASPHALT SHINGLE ROOFING TO REMAIN, REMOVE AND REPLACE AS NECESSARY TO PERFORM
REQUIRED ROOF TO DORMER AND DIVERTER FLASHING INTEGRATION
EXISTING CORRUGATED METAL WINDOW AWNING TO BE REMOVED AND DISPOSED OF.16
EXISTING STRUCTURAL WOOD POSTS AT ENTRY ROOF OVERHANGS TO REMAIN IN PLACE.17
EXISTING BUILDING LIGHTING FIXTURES TO BE REMOVED, SAFELY STORED, AND REINSTALLED ON DETAILED MOUNTING
BLOCKS PER DEIGN PACKAGE.
EXISTING BUILDING SIGNAGE PACKARD TO BE REMOVED, SAFELY STORED, AND REINSTALLED ON OVERSIZED MOUNTING
BLOCKS PER DEIGN PACKAGE.
NOT USED.12
NOT USED.8
TYP.1
TYP.1
TYP.2
TYP.2
TYP.3
TYP.3
TYP.3
TYP.4
TYP.4
TYP.5TYP.5
TYP. 5
TYP. 4
TYP.7
TYP.7
TYP.7
TYP.9
TYP.17
TYP.17
TYP.17
18TYP.
A3.01
A3.01
A3.01
A3.01
A3.01
A3.02
A3.02
A3.02
A3.02
A3.02
A3.02
TYP.
TYP.
TYP.
TYP.
TYP.
A3.03
A3.03
LOCATION OF EXISTING
CONCRETE RAMP
INSTALL 'NEW' 1 1/2" O.D. GALV. TUBE STEEL HANDRAIL
MOUNT @ +3'-0" ABOVE RAMP SURFACE AND EXTEND
12" BEYOND TOP AND BOTTOM TRANSITION
A3.04
A3.05
A3.05
A3.05
A3.05
A3.05
A3.05
A4.02
A4.02
A4.01 TYP.
TYP.
TYP.
A4.02
A4.02
A4.01 TYP.
TYP.
TYP.
A4.03
A4.03
TYP.
A4.03
LOCATION OF EXISTING
CONCRETE LOADING PLATFORM
LOCATION OF
EXISTING
CONCRETE
STAIRS
LOCATION OF EXISTING
CONCRETE LOADING PLATFORM
LOCATION OF EXISTING
CONCRETE STAIRS
OPERABLE WINDOW LOCATIONS NOTE:
ALL REPLACEMENT FIRST FLOOR AND SECOND FLOOR WINDOW UNITS SHALL HAVE OPERABLE MECHANISMS MATCHING INTENDED ORIGINAL WINDOW FUNCTIONS AND INCLUDE BLACK ALUMINUM MESH REMOVABLE SCREENS. THE EXCEPTION SHALL BE THE SECOND FLOOR WEST AND EAST (FRONT AND REAR) ELEVATION AT BUILDING 'A' WINDOWS LOCATED IN THE DORMERS, WHICH SHALL BE NON-SCREENED INOPERABLE UNITS.
A2.01
BUILDING
ELEVATIONS
08.04.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-095
Permit Issue Set
O re go n
D ep ar tm en t o f F or es try
Fo re st G ro ve
W ar eh ou se a nd F ire C ac he
C la dd in g an d W in do w R ep la ce m en t (
P O
-6
-0
7)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
G al es C re ek
R d.
, F or es t G ro ve
, O R
2 WAREHOUSE BUILDING 'B' SIDE ELEVATION
1/4" = 1'-0" ORIENTED FACING NORTH
mhg
1 WAREHOUSE BUILDING 'B' REAR ELEVATION
1/4" = 1'-0" ORIENTED FACING WEST
mhg
EXISTING CONCRETE FOUNDATION WALLS, ENTRY PORCHES, AND WALKWAYS TO REMAIN, REFER TO BASE OF WALL DETAILS FOR
INTEGRATION OF WRB AND FLASHING PROVISIONS.
ELEVATION KEYNOTES:
EXISTING CEDAR LAP SIDING AND TRIM TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FIBER CEMENT PLANK LAP CLADDING AND TRIM INSTALLED OVER PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT
HORIZONTAL TERMINATIONS, REFER TO WALL DETAILS AND PROJECT MANUAL.
REMOVE, LEGALLY DISPOSE OF, AND REPLACE 100% OF EXISTING GUTTER AND DOWNSPOUT ASSEMBLIES AT EXISTING LOCATIONS, REFER TO PROJECT DESIGN DOCUMENTS AND PROJECT MANUAL.
IDENTIFIED LOCATION OF EXISTING UTILITY SERVICE CONNECTIONS. REFER TO WALL DETAILS.
ELEVATION NOTES:
1. ELEVATIONS ARE PRODUCED USING INFORMATION ACQUIRED FROM PUBLIC RECORD, LIMITED SITE OBSERVATIONS, OWNER FURBISHED DATA, AND/OR DOCUMENTS PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND REQUEST A REVIEW. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO NOTICE TO PROCEED FROM OWNER, PRODUCT OR MATERIALS TAKE-OFFS, PRODUCT OR MATERIALS PROCUREMENT, OR FABRICATOR SHOP-DRAWING PRODUCTIONS.
2. COORDINATE DEMOLITION WITH EXTERIOR CLADDING AND WINDOW REPLACEMENT PER THE DESIGN DOCUMENTS.
PERFORM SELECTIVE AND LIMITED DEMOLITION OF EXISTING EXTERIOR SHEATHING AND ROOFING AS REQUIRED.
3. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF
SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.
4. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH
PLANE OF EXISTING ADJACENT SURFACES.
ELECTRICAL SERVICE MAST ROOF PENETRATION TO REMAIN. DISCONNECT FROM METER BASE AS REQUIRED FOR
REQUIRED CLADDING AND TRIM WORK
EXISTING ROLL-UP DOOR UNITS, INCLUDING ADJACENT TRIM AND CONCEALED COMPONENTS TO REMAIN IN PLACE WITH R.O. TRIM AND WEATHER BARRIER COMPONENTS TO BE REMOVED A ND REPLACED. INSTALL RELATED SAM WRAP FLASHING, METAL HEAD FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED SEALANT JOINTS AT FIBER CEMENT TRIM ALONG DOOR JAMBS.
REFER TO WALL OPENING DETAILS, AND PROJECT MANUAL.
11 NOT USED.
EXISTING WINDOW UNITS, INCLUDING ADJACENT TRIM (AS OCCURS) AND CONCEALED COMPONENTS TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FLANGED VINYL WINDOW UNIT, INCLUDING RELATED SAM PRE AND POST WRAP FLASHING, METAL HEAD FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM ALONG 100% OF WINDOW PERIMETERS. REFER TO WALL OPENING DETAILS AND PROJECT MANUAL.
EXISTING NORTH ELEVATION ENTRY SWING DOOR UNITS, INCLUDING ADJACENT TRIM AND CONCEALED COMPONENTS TO BE REMOVED, DISPOSED OF, AND REPLACED. INSTALL SCHEDULED SOLID CORE DOOR UNIT WITH RELATED SAM PRE AND POST WRAP FLASHING, METAL HEAD AND SILL PAN FLASHING, AND RELATED CONCEALED COMPONENTS. INSTALL SCHEDULED DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM ALONG DOOR HEAD AND JAMB PERIMETERS. REFER TO WALL OPENING DETAILS, AND PROJECT MANUAL.
EXISTING VERTICAL CEDAR PANEL SIDING, BATTENS, AND TRIM TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FIBER CEMENT PANEL CLADDING, BATTENS, AND TRIM INSTALLED OVER PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT HORIZONTAL TERMINATIONS, MATCH EXISTING BATTEN LOCATIONS. REFER TO WALL DETAILS AND PROJECT
MANUAL.
NOT USED.15
NOT USED.
EXISTING COMPOSITION ASPHALT SHINGLE ROOFING TO REMAIN, REMOVE AND REPLACE AS NECESSARY TO PERFORM
REQUIRED ROOF TO DORMER AND DIVERTER FLASHING INTEGRATION
NOT USED.16
EXISTING STRUCTURAL WOOD POSTS AT ENTRY ROOF OVERHANGS TO REMAIN IN PLACE.17
EXISTING BUILDING LIGHTING FIXTURES TO BE REMOVED, SAFELY STORED, AND REINSTALLED ON DETAILED MOUNTING
BLOCKS PER DEIGN PACKAGE.
NOT USED.12
NOT USED.8
EXISTING BUILDING SIGNAGE PACKARD TO BE REMOVED, SAFELY STORED, AND REINSTALLED ON OVERSIZED MOUNTING
BLOCKS PER DEIGN PACKAGE.
TYP.1
TYP.1
TYP.2
TYP.2
TYP.3
TYP.3
TYP.4
TYP.4
TYP. 4
TYP.4
TYP. 5
TYP.7
TYP.7
TYP.7
TYP.7
TYP.9
TYP. 17
TYP.17
A3.01
A3.01
A3.01
A3.01
A3.01
A3.01
A3.01
A3.02 TYP.
A3.02
TYP.
A3.02 TYP.
A3.04
A3.05
A3.05
A3.05
A3.05
A3.05
A4.02
A4.02
A4.01 TYP.
TYP.
TYP.
A4.02
A4.02
A4.01 TYP.
TYP.
TYP.
A4.02
LOCATION OF EXISTING
CONCRETE RAMP
OPERABLE WINDOW LOCATIONS NOTE:
ALL REPLACEMENT FIRST FLOOR AND SECOND FLOOR WINDOW UNITS SHALL HAVE OPERABLE MECHANISMS MATCHING INTENDED ORIGINAL WINDOW FUNCTIONS AND INCLUDE BLACK ALUMINUM MESH REMOVABLE SCREENS. THE EXCEPTION SHALL BE THE SECOND FLOOR WEST AND EAST (FRONT AND REAR) ELEVATION AT BUILDING 'A' WINDOWS LOCATED IN THE DORMERS, WHICH SHALL BE NON-SCREENED INOPERABLE UNITS.
TYP.3
A2.02
BUILDING
ELEVATIONS
08.04.2025
SHEET NAME
REVISIONS
ISSUE
REV. DATE
PROJECT NAME
CLIENT
PROJECT NUMBER
SHEET NUMBER
15 82nd Drive, Suite 10 Gladstone, OR 97027
TEL: 503.772.1114
FAX: 503.772.4039
www.forensicbuilding.com info@forensicbuilding.com
COPYRIGHT ©2025 FORENSIC
BUILDING CONSULTANTS
All Rights Reserved
PRINT ALL DETAILS IN
COLOR AT 24x36
OR CCB# 155496
WA FORENW C94308
UT #8334529-5501
(RE) 25-095
Permit Issue Set
O re go n
D ep ar tm en t o f F or es try
Fo re st G ro ve
W ar eh ou se a nd F ire C ac he
C la dd in g an d W in do w R ep la ce m en t (
P O
-6
-0
7)
O re go n
De pa rtm en t o f F or es try
S ta te
S tre et , B ui ld in g
F, S al em
, O R
G al es C re ek
R d.
, F or es t G ro ve
, O R
1 FIRE CACHE BUILDING 'E' FRONT ELEVATION
1/4" = 1'-0" ORIENTED FACING SOUTH
mhg
2 FIRE CACHE BUILDING 'E' SIDE ELEVATION
1/4" = 1'-0" ORIENTED FACING WEST
mhg
EXISTING CONCRETE FOUNDATION WALLS, ENTRY PORCHES, AND WALKWAYS TO REMAIN, REFER TO BASE OF WALL DETAILS FOR
INTEGRATION OF WRB AND FLASHING PROVISIONS.
ELEVATION KEYNOTES:
EXISTING CEDAR LAP SIDING AND TRIM TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FIBER CEMENT PLANK LAP CLADDING AND TRIM INSTALLED OVER PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT
HORIZONTAL TERMINATIONS, REFER TO WALL DETAILS AND PROJECT MANUAL.
REMOVE, LEGALLY DISPOSE OF, AND REPLACE 100% OF EXISTING GUTTER AND DOWNSPOUT ASSEMBLIES AT EXISTING LOCATIONS, REFER TO PROJECT DESIGN DOCUMENTS AND PROJECT MANUAL.
IDENTIFIED LOCATION OF EXISTING UTILITY SERVICE CONNECTIONS. REFER TO WALL DETAILS.
ELEVATION NOTES:
1. ELEVATIONS ARE PRODUCED USING INFORMATION ACQUIRED FROM PUBLIC RECORD, LIMITED SITE OBSERVATIONS, OWNER FURBISHED DATA, AND/OR DOCUMENTS PREPARED BY ORIGINAL/PREVIOUS ARCHITECT, DESIGNER, AND/OR CONSULTANT. BRING ANY DISCREPANCIES BETWEEN DESIGN DOCUMENTS AND ACTUAL PROJECT CONDITIONS TO THE IMMEDIATE ATTENTION OF THE BUILDING ENCLOSURE CONSULTANT AND REQUEST A REVIEW. CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS PRIOR TO NOTICE TO PROCEED FROM OWNER, PRODUCT OR MATERIALS TAKE-OFFS, PRODUCT OR MATERIALS PROCUREMENT, OR FABRICATOR SHOP-DRAWING PRODUCTIONS.
2. COORDINATE DEMOLITION WITH EXTERIOR CLADDING AND WINDOW REPLACEMENT PER THE DESIGN DOCUMENTS.
PERFORM SELECTIVE AND LIMITED DEMOLITION OF EXISTING EXTERIOR SHEATHING AND ROOFING AS REQUIRED.
3. VERIFY CLEARANCE REQUIREMENTS AND MATCH ASSEMBLY OF EXISTING FIRE RATED WALLS AND ROOF
SYSTEMS WHERE REPAIRED DURING THE COURSE OF REQUIRED WORK.
4. REPLACE EXTERIOR PLYWOOD AND GYPSUM WALLBOARD SHEATHING AS NECESSARY TO PERFORM REQUIRED WORK AND AS NECESSARY TO CHASE DAMAGE TO EXTINCTION. PATCH, REPAIR, AND MATCH
PLANE OF EXISTING ADJACENT SURFACES.
NOT USED.
EXISTING ROLL-UP DOOR UNITS, INCLUDING ADJACENT TRIM AND CONCEALED COMPONENTS TO REMAIN IN PLACE WITH R.O. TRIM AND WEATHER BARRIER COMPONENTS TO BE REMOVED A ND REPLACED. INSTALL RELATED SAM WRAP FLASHING, METAL HEAD FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED SEALANT JOINTS AT FIBER CEMENT TRIM ALONG DOOR JAMBS.
REFER TO WALL OPENING DETAILS, AND PROJECT MANUAL.
11 NOT USED.
EXISTING WINDOW UNITS, INCLUDING ADJACENT TRIM (AS OCCURS) AND CONCEALED COMPONENTS TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FLANGED VINYL WINDOW UNIT, INCLUDING RELATED SAM PRE AND POST WRAP FLASHING, METAL HEAD FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM ALONG 100% OF WINDOW PERIMETERS. REFER TO WALL OPENING DETAILS AND PROJECT MANUAL.
EXISTING ENTRY SWING DOOR UNITS, INCLUDING ADJACENT TRIM AND CONCEALED COMPONENTS TO BE REMOVED, SAFELY STORED, AND REINSTALLED. REINSTALL DOOR UNITS WITH RELATED SAM PRE AND POST WRAP FLASHING, METAL HEAD AND SILL PAN FLASHING, AND RELATED CONCEALED COMPONENTS, TYPICAL. INSTALL SCHEDULED DYNAMIC SEALANT JOINTS AND FIBER CEMENT TRIM ALONG DOOR HEAD AND JAMB PERIMETERS. REFER TO WALL OPENING DETAILS, AND PROJECT MANUAL.
EXISTING VERTICAL CEDAR PANEL SIDING, BATTENS, AND TRIM TO BE REMOVED AND LEGALLY DISPOSED OF. INSTALL SCHEDULED REPLACEMENT FIBER CEMENT PANEL CLADDING, BATTENS, AND TRIM INSTALLED OVER PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT HORIZONTAL TERMINATIONS, MATCH EXISTING BATTEN LOCATIONS. REFER TO WALL DETAILS AND PROJECT
MANUAL.
NOT USED.15
WHERE SINGLE-WALL CONSTRUCTION OCCURS AT EXISTING T1-11 AND CEDAR PANELS, IF DEEMED APPROPRIATE, PANELS MAY BE USED AS WALL SHEATHING. WHERE INSUFFICIENT OR DAMAGED, REMOVE AND LEGALLY DISPOSED OF FOR INFILL AND/OR INSTALL 'NEW' CDX PLYWOOD SHEATHING. INSTALLED EXTERIOR SIDING SHALL CONSIST OF SCHEDULED FIBER CEMENT PLANK LAP CLADDING AND TRIM INSTALLED OVER PRESSURE TREATED FURRING STRIPS WITH INSECT SCREENS AT HORIZONTAL TERMINATIONS. REFER TO WALL
DETAILS AND PROJECT MANUAL.
EXISTING COMPOSITION ASPHALT SHINGLE ROOFING TO REMAIN, REMOVE AND REPLACE AS NECESSARY TO PERFORM
REQUIRED ROOF TO DORMER AND DIVERTER FLASHING INTEGRATION
NOT USED.16
EXISTING STRUCTURAL WOOD POSTS AT ENTRY ROOF OVERHANGS TO REMAIN IN PLACE.17
EXISTING BUILDING LIGHTING FIXTURES TO BE REMOVED, SAFELY STORED, AND REINSTALLED ON DETAILED MOUNTING
BLOCKS PER DEIGN PACKAGE.
NOT USED.12
NOT USED.8
EXISTING BUILDING SIGNAGE…