ATTACHMENT_B_Reevesville_Water_Line_Improvements_Drawings.Stamped_For_Bids.pdf
PDF 18 MB Posted
- Attached to
- Reevesville Water Line Improvements
- Solicitation number
- 2026-46
- Issued by
- Dorchester County, South Carolina
About this file
This is a technical drawings document prepared for the Reevesville Water Line Improvements project in Dorchester County, South Carolina. The document serves as Attachment B to the Invitation for Bids and contains general notes, construction details, erosion control specifications, and plan sheets for the 8-inch water main installation project across multiple streets including Blossom Street, Main Street, Reeves Street, Johnston Avenue, and Heaton Street. The drawings include a comprehensive drawing index referencing plan sheets (C01-C06), standard details (D01-D02), traffic control details (D03-D04), and erosion control notes and details (G01-G03). Key construction specifications outlined in the general notes address contractor obligations including utility locating requirements through Palmetto Utility Protection Service, pipe deflection limitations for restrained joint piping, flowable fill requirements for roadway crossings and pavement restoration, and field cutting procedures prohibiting torch-cutting and requiring AWWA and ASTM compliance. The drawings detail fire hydrant placement requirements of minimum 10 feet from pavement edges, horizontal directional drilling specifications with restrained joint piping and air release valve installations, and standard water main bedding and pavement cut details.
The document establishes a comprehensive sequence of construction operations requiring NPDES stormwater discharge permit coverage from South Carolina Department of Health and Environmental Control prior to work commencement, pre-construction meetings, installation of erosion and sedimentation control measures including silt fence with specific fabric and post specifications, sediment tubes, construction entrances with stone pads, and temporary stockpile area management. Sediment and erosion control requirements mandate weekly inspections, maintenance of control devices during all construction phases, sediment removal when accumulation reaches one-third fence height, stabilization measures within fourteen days of work cessation except where precluded by weather, and permanent seeding schedules specifying application rates and planting dates for temporary measures such as grain rye or millet and permanent measures including bahia grass, bermuda grass, and lespedeza with associated limestone and fertilizer amendments. Standard construction details include water service line installations with meter box specifications, fire hydrant assemblies with protective collars and tie rods, valve and valve box installations with marker plates, pavement cut details specifying minimum depths and flowable fill requirements, water main bedding specifications requiring structural backfill compaction to 95 percent of modified Proctor maximum dry density, and air release valve pedestal assemblies. The drawings were dated June 2023 with revisions issued July 21, 2025, and were prepared by engineering personnel designated as CR (Project Engineer), SL/MCM (Design), and JC/OW (Checked By).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R E
E V
E S
V
IL
LE
W
A T
E R
L
IN
E
IM
P R
O V
E M
E N
T S
G E
N E
R A
L N
O T
E S
A N
D D
R A
W
IN
G S
I N
D E
X D
O R
C H
E S
T E
R C
O U
N T
Y W
A T
E R
A N
D S
E W
E R
D E
P A
R T
M E
N T
G01
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text No. 29604
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
TOWN OF REEVESVILLE DORCHESTER COUNTY, SOUTH CAROLINA
AutoCAD SHX Text
235 DEMING WAY SUMMERVILLE, SC 29483 PHONE: (843) 832-0075 FAX: (843) 832-0073
AutoCAD SHX Text
DATE: PROJECT ENGINEER: DESIGN BY: DRAWN BY: CHECKED BY:
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
JUNE 2023 CR CR SL/MCM JC/OW
AutoCAD SHX Text DRAWING INDEX DRAWING NUMBER DRAWING TITLE DRAWING TITLE GENERAL - COVER SHEET COVER SHEET G01.............................................GENERAL NOTES AND DRAWING INDEX G02............................................ EROSION AND CONTROL NOTES AND DETAILS EROSION AND CONTROL NOTES AND DETAILS G03............................................ EROSION AND CONTROL NOTES AND DETAILS EROSION AND CONTROL NOTES AND DETAILS 8-INCH WATER MAIN C01............................................ BLOSSOM ST PLAN - STA 0+00 T0 STA 11+09 BLOSSOM ST PLAN - STA 0+00 T0 STA 11+09 C02............................................ MAIN ST PLAN - STA 0+00 T0 STA 17+42 MAIN ST PLAN - STA 0+00 T0 STA 17+42 REEVES ST PLAN - STA 0+00 TO STA 5+00 C03............................................ REEVES ST PLAN - STA 5+00 T0 STA 18+00 REEVES ST PLAN - STA 5+00 T0 STA 18+00 C04............................................ REEVES ST PLAN - STA 18+00 T0 STA 21+50 REEVES ST PLAN - STA 18+00 T0 STA 21+50 HEATON ST PLAN - STA 21+50 TO 32+30 C05............................................ PLAN AND PROFILE - STA 16+75 T0 STA 19+75 PLAN AND PROFILE - STA 16+75 T0 STA 19+75 C06............................................JOHNSTON AVENUE - STA 0+00 TO STA 4+94 D01............................................ STANDARD DETAILS STANDARD DETAILS D02............................................ STANDARD DETAILS STANDARD DETAILS D03............................................TRAFFIC CONTROL DETAILS D04............................................TRAFFIC CONTROL DETAILS
AutoCAD SHX Text
- RIGHT-OF-WAY
AutoCAD SHX Text
- SEWER MANHOLE
AutoCAD SHX Text
- CONTOUR LINE
AutoCAD SHX Text
AutoCAD SHX Text
- FENCE
AutoCAD SHX Text
- OVERHEAD POWER
AutoCAD SHX Text
- SEWER LINE
AutoCAD SHX Text
- WATER LINE
AutoCAD SHX Text S
AutoCAD SHX Text
LEGEND:
AutoCAD SHX Text
- SEWER VALVE
AutoCAD SHX Text
- GAS LINE
AutoCAD SHX Text
- FIBER OPTIC
AutoCAD SHX Text
- TELEPHONE LINE
AutoCAD SHX Text
- EDGE OF WOODS
AutoCAD SHX Text
- POWER POLE
AutoCAD SHX Text
- GUY WIRE
AutoCAD SHX Text
- TELEPHONE PEDESTAL
AutoCAD SHX Text
- MAILBOX
AutoCAD SHX Text T
AutoCAD SHX Text
MB
AutoCAD SHX Text
- STORM DRAIN MANHOLE
AutoCAD SHX Text D
AutoCAD SHX Text GENERAL NOTES: 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS AND ALL APPLICABLE PERMITS. 2. HORIZONTAL DATUM IS NAD 83, STATE PLANE COORDINATES. HORIZONTAL DATUM IS NAD 83, STATE PLANE COORDINATES. ALL VERTICAL DATUM (ELEVATIONS) ARE NAVD88. 3. LOCATION SHOWN FOR UNDERGROUND UTILITIES AND LOCATION SHOWN FOR UNDERGROUND UTILITIES AND STRUCTURES ARE BASED ON FIELD SURVEYS, DORCHESTER COUNTY GIS, AND RECORD DRAWINGS. THESE LOCATIONS SHALL BE FIELD VERIFIED BY THE CONTRACTOR BOTH HORIZONTALLY AND VERTICALLY. CALL “PALMETTO UTILITY PALMETTO UTILITY PROTECTION SERVICE” (PUPS) (811 OR 888-721-7877) AT (PUPS) (811 OR 888-721-7877) AT LEAST 3 WORKING DAYS PRIOR TO DIGGING FOR LOCATION ASSISTANCE. CONTRACTOR IS RESPONSIBLE FOR CONTACTING ALL UTILITIES, WHETHER THEY ARE A MEMBER OF PUPS OR NOT, PRIOR TO DIGGING. 4. CONTRACTOR TO LOCATE UTILITIES IN ADVANCE OF WORK CONTRACTOR TO LOCATE UTILITIES IN ADVANCE OF WORK TO DETERMINE THE MATERIAL, EXACT SIZE, DEPTH, AND LOCATION. 5. WHERE RESTRAINED JOINT PIPE IS CALLED FOR, PIPE WHERE RESTRAINED JOINT PIPE IS CALLED FOR, PIPE DEFLECTION CANNOT EXCEED A MAXIMUM OF ONE (1) DEGREE PER JOINT OR PER PIPE MANUFACTURER'S RECOMMENDATIONS. 6. ALL AREAS DISTURBED BEYOND INDICATED LIMITS OF ALL AREAS DISTURBED BEYOND INDICATED LIMITS OF DISTURBANCE SHALL BE RESTORED TO PRE-EXISTING CONDITIONS REGARDLESS OF AREA AFFECTED AT NO ADDITIONAL COST TO DCWS. 7. WHEN FIELD CUTTING OF PIPE IS NECESSARY, THE WHEN FIELD CUTTING OF PIPE IS NECESSARY, THE CONTRACTOR SHALL CUT PIPE WITH A PIPE SAW IN ACCORDANCE WITH APPLICABLE AWWA AND ASTM REQUIREMENTS. FIELD WELDING OR TORCH-CUTTING ARE PROHIBITED. 8. FLOWABLE FILL SHALL BE USED AS BACK FILL MATERIAL FLOWABLE FILL SHALL BE USED AS BACK FILL MATERIAL FOR ALL ROADWAY CROSSINGS AND FOR EXCAVATION WITHIN 5 FEET FROM EDGE OF PAVEMENT FOR HIGH VOLUME ROADWAYS AND/OR WITHIN 3 FEET OF EDGE OF PAVEMENT FOR LOW VOLUME ROADWAYS 9. ALL ABANDONED LINES SHOULD BE FILLED WITH FLOWABLE ALL ABANDONED LINES SHOULD BE FILLED WITH FLOWABLE FILL PER SCDOT REQUIREMENTS. 10. ALL UTILITY LINES CROSSINGS UNDER STATE ROADWAYS ALL UTILITY LINES CROSSINGS UNDER STATE ROADWAYS MUST BE AT A MINIMUM DEPTH OF 48". 11. ALL WATER METERS AND AIR RELEASE VALVES SHALL BE ALL WATER METERS AND AIR RELEASE VALVES SHALL BE PLACED AT TEH RIGHT-OF-WAY LINE. 12. THE DEPTH OF UTILITY LINE MUST MEET THE MINIMUM THE DEPTH OF UTILITY LINE MUST MEET THE MINIMUM REQUIREMENTS PER THE UAM: 42" BELOW THE LOWEST POINT OF THE ROADWAY CROSS SECTION. THE ROADWAY CROSS SECTION INCLUDES ANY DRAINAGE AND/OR DITCHES OR SWALES. 13. IF THERE IS ANY DIGGING, EXCAVATING, TRENCHING, BORING, IF THERE IS ANY DIGGING, EXCAVATING, TRENCHING, BORING, ETC. WITHIN 500 FEET OF A SIGNALIZED INTERSECTION, THE PERMITTEE IS RESPONSIBLE FOR CONTACTING THE SCDOT TRAFFIC SIGNAL SHOP AT (843) 740-1668 BEFORE WORK BEGINS. 14. DRIVEWAYS THAT ARE IMPACTED BY OPEN-CUT DRIVEWAYS THAT ARE IMPACTED BY OPEN-CUT INSTALLATION METHOD, SHALL BE OVERLAID FOR THE FULL WIDTH WITHIN THE RIGHT OF WAY LIMITS WITH LIKE MATERIAL. 15. FINAL MILL AND OVERLAY SHALL BE 5' ON EACH SIDE OF FINAL MILL AND OVERLAY SHALL BE 5' ON EACH SIDE OF THE ROAD CUT AND EXTEND THE FULL LANE WIDTH. IF CUT ENCROACHES ON MORE THAN ONE LANE, THEN FINAL MILL AND OVERALL WILL EXTEND THE FULL WIDTH OF SECOND LANE. IF ROAD CUT IS IN THE INTERSECTION, THE ENTIRE INTERSECTION SHALL BE MILLED AND OVERLAID RADIUS TO RADIUS. 16. FIRE HYDRANTS SHALL BE PLACED A MINIMUM OF 10 FEET FIRE HYDRANTS SHALL BE PLACED A MINIMUM OF 10 FEET FROM THE EDGE OF THE PAVEMENT AND/OR BEHIND DITCH LINES. 17. BORE PITS SHOULD HAVE A MINIMUM OF 5 FEET FROM THE BORE PITS SHOULD HAVE A MINIMUM OF 5 FEET FROM THE ROADWAY AND ANY ENCASEMENTS SHALL EXTEND 6 FEET BEYOND THE EDGE OF PAVEMENT. 18. ANY AND ALL VENTS INSTALLED FOR CASING PIPE MUST BE ANY AND ALL VENTS INSTALLED FOR CASING PIPE MUST BE LOCATED AT THE RIGHT-OF-WAY LINE.
AutoCAD SHX Text SEQUENCE OF CONSTRUCTION OPERATIONS: 1. NO WORK TO BE PERFORMED PRIOR TO RECEIPT OF NO WORK TO BE PERFORMED PRIOR TO RECEIPT OF NPDES COVERAGE FROM SOUTH CAROLINA DEPARTMENT OF HEALTH AND ENVIRONMENTAL CONTROL (SCDHEC). 2. CONTRACTOR TO SCHEDULE A PRE-CONSTRUCTION CONTRACTOR TO SCHEDULE A PRE-CONSTRUCTION MEETING PRIOR TO ANY COMMENCEMENT OF WORK. 3. CONTRACTOR SHALL CONTACT THE SCDHEC REGIONAL CONTRACTOR SHALL CONTACT THE SCDHEC REGIONAL EA OFFICE LISTED BELOW PRIOR TO STARTING ANY LAND-DISTURBING ACTIVITIES. THE CONTRACTOR SHALL ABIDE BY ALL REQUIREMENTS OF THE SOUTH CAROLINA NPDES GENERAL PERMIT FOR STORMWATER DISCHARGES FROM CONSTRUCTION ACTIVITIES SCR100000. LOWCOUNTRY EA CHARLESTON 1362 McMILLAN AVENUE, SUITE 300 CHARLESTON, SC 29405 (843) 953-0150 4. INSTALL EROSION AND SEDIMENTATION CONTROL INSTALL EROSION AND SEDIMENTATION CONTROL MEASURES AS SHOWN ON THE CONTRACT DRAWINGS. NO CONSTRUCTION OR LAND DISTURBANCE ACTIVITIES MAY BEGIN UNTIL ALL EROSION AND SEDIMENTATION CONTROL MEASURES HAVE BEEN INSTALLED AROUND CONSTRUCTION AREAS. IF CLEARING IS REQUIRED FOR INSTALLATION OF A GIVEN MEASURE, ALL OTHER MEASURES SHOWN SHALL BE INSTALLED FIRST. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS BETWEEN THE DISTURBED AREA AND ALL WATERS OF THE STATE (WoS). A 10-FOOT BUFFER SHALL BE MAINTAINED WHERE POSSIBLE BETWEEN THE SILT FENCE AND THE WoS. 5. ONCE ALL MEASURES HAVE BEEN INSTALLED, THE SITE ONCE ALL MEASURES HAVE BEEN INSTALLED, THE SITE SHALL BE CLEARED AND GRUBBED AS SHOWN ON THE CONTRACT DRAWINGS. CONTRACTOR LAYDOWN/STOCKPILE/CONCRETE WASHOUT AREAS SHALL BE LOCATED AS SHOWN ON THE CONTRACT DRAWINGS. 6. ALL PIPE WORK SHALL BE INSTALLED IN ACCORDANCE ALL PIPE WORK SHALL BE INSTALLED IN ACCORDANCE WITH STANDARD CONSTRUCTION TECHNIQUES.ONLY THE LENGTH OF TRENCH IN WHICH PIPE CAN BE INSTALLED IN ONE DAY'S TIME SHALL BE OPEN AT ANY TIME, WITH SPOIL MATERIAL PLACED ON THE UPHILL SIDE OF THE TRENCH. PIPING SHALL BE CAPPED AT END OF EACH WORK DAY TO PREVENT SEDIMENT FROM ENTERING. TRENCHES SHALL BE BACKFILLED AT END OF EACH WORK DAY AND DISTURBED AREA SEEDED WITH TEMPORARY SEEDING MEASURES AS NECESSARY. 7. EARTHWORK EXCAVATION AND FILL OPERATIONS SHALL EARTHWORK EXCAVATION AND FILL OPERATIONS SHALL BE PERFORMED IN ACCORDANCE WITH STANDARD CONSTRUCTION TECHNIQUES. ALL EXCAVATION DEWATERING FLOWS SHALL PASS THROUGH A SEDIMENT FILTERING DEVICE PRIOR TO DISCHARGE. TOPSOIL SHALL BE STRIPPED AND STOCKPILED ON SITE. TOPSOIL STOCKPILE SHALL HAVE PERIMETER EROSION CONTROL MEASURES INSTALLED AND SEEDED WITH TEMPORARY SEEDING MEASURES DURING CONSTRUCTION ACTIVITIES. 8. STORM DRAINAGE DITCHES SHALL BE PROTECTED WITH STORM DRAINAGE DITCHES SHALL BE PROTECTED WITH APPROPRIATE EROSION CONTROL MEASURES AT ALL TIMES. POSITIVE STORMWATER DRAINAGE AWAY FROM CONSTRUCTION ACTIVITIES SHALL BE MAINTAINED AT ALL TIMES DURING CONSTRUCTION. 9. TEMPORARY SEEDING MEASURES SHALL BE EMPLOYED TEMPORARY SEEDING MEASURES SHALL BE EMPLOYED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED, EXCEPT WHERE STABILIZATION MEASURES WOULD BE PRECLUDED BY SNOW OR FROZEN GROUND CONDITIONS, OR WHERE CONSTRUCTION ACTIVITY WILL BE RESUMED WITHIN 14 DAYS. 10. ONCE ALL EARTHWORK AND CONSTRUCTION ACTIVITIES ONCE ALL EARTHWORK AND CONSTRUCTION ACTIVITIES ARE COMPLETE, FINAL GRADING MAY BEGIN. 11. UPON COMPLETION OF FINAL GRADING, PERMANENT UPON COMPLETION OF FINAL GRADING, PERMANENT SEEDING, MULCHING, AND FERTILIZING MEASURES SHALL BE EMPLOYED ON ALL DISTURBED AREAS AS SPECIFIED IN THE CONTRACT DOCUMENTS. ALL EROSION CONTROL MEASURES SHALL REMAIN IN PLACE UNTIL ENTIRE SITE HAS BEEN STABILIZED. 12. ONCE PERMANENT STABILIZATION HAS OCCURRED AND ONCE PERMANENT STABILIZATION HAS OCCURRED AND APPROVED BY LOCAL AUTHORITIES, CONTRACTOR SHALL FILE A NOTICE OF TERMINATION (NOT) AS PER THE REQUIREMENTS OF THE SOUTH CAROLINA NPDES GENERAL PERMIT FOR STORMWATER DISCHARGES FROM CONSTRUCTION ACTIVITIES SCR100000. ANY AREAS DISTURBED BY THE REMOVAL OF THESE MEASURES SHALL BE RETURNED AS CLOSELY AS POSSIBLE TO ORIGINAL CONDITION AND SEEDED, MULCHED, AND FERTILIZED AS SPECIFIED IN THE CONTRACT DOCUMENTS.
AutoCAD SHX Text SEDIMENT AND EROSION CONTROL: 1. IF NECESSARY, SLOPES, WHICH EXCEED WIGHT (8) IF NECESSARY, SLOPES, WHICH EXCEED WIGHT (8) VERTICAL FEET SHOULD BE STABILIZED WITH SYNTHETIC OR VEGETATIVE MATS, IN ADDITION TO HYDROSEEDING IT MAY BE NECESSARY TO INSTALL TEMPORARY SLOPE DRAINS DURING CONSTRUCTION. TEMPORARY BERMS MAY BE NEEDED UNTIL THE SLOPE IS BROUGHT TO GRADE. 2. STABILIZATION MEASURES SHALL BE INITIATED AS STABILIZATION MEASURES SHALL BE INITIATED AS SOON AS PRACTICABLE IN PORTIONS OF THE SITE WHERE CONSTRUCTION ACTIVITIES HAVE TEMPORARILY OR PERMANENTLY CEASED, BUT IN NO CASE MORE THAN FOURTEEN (14) DAYS AFTER WORK HAS CEASED, EXCEPT AS STATED BELOW: WHERE STABILZIATION BY THE 14TH DAY IS PRECLUDED BY SNOW COVER OR FORZEN GROUND CONDITIONS STABILIZATION MEASURES MUST BE INITIATED AS SOON AS PRACTICABLE. WHERE CONSTRUCTION ACTIVITY ON A PORTION OF THE SITE IS TEMPORARILY CEASED, AND EARTH-DISTURBING ACTIVITIES WILL BE RESUMED WITHIN 14 DAYS, TEMPORARILY STABILIZATION MEASURES DO NOT HAVE TO BE INITIATED ON THAT PORTION OF THE SITE. 3. ALL SEDIMENT AND EROSION CONTROL DEVICES ALL SEDIMENT AND EROSION CONTROL DEVICES SHALL BE INSPECTED ONCE EVERY CALENDAR WEEK. IF PERIODIC INSPECTION OR OTHER INFORMATION INDICATES THAT A BMP HAS BEEN INAPPROPRIATELY OR INCORRECTLY INSTALLED, THE PERMITTEE MUST ADDRESS THE NECESSARY REPLACEMENT OR MODIFICATION REQUIRED TO CORRECT THE BMP WITHIN 48 HOURS OF IDENTIFICATION. 4. PROVIDE SILT FENCE AND/OR OTHER CONTROL PROVIDE SILT FENCE AND/OR OTHER CONTROL DEVICES, AS MAY BE REQUIRED, TO CONTROL SOIL EROSION DURING UTILITY CONSTRUCTION. ALL DISTURBED AREAS SHALL BE CLEANED, GRADED, AND STABILIZED WITH GRASSING IMMEDIATELY AFTER THE UTILITY INSTALLATION. FILL, COVER, AND TEMPORARY SEEDING AT THE END OF EACH DAY ARE RECOMMENDED. IF WATER IS ENCOUNTERED WHILE TRENCHING, THE WATER SHOULD BE FILTERED TO REMOVE SEDIMENT BEFORE BEING PUMPED BACK INTO ANY WATERS OF THE STATE (WoS). 5. ALL EROSION CONTROL DEVICES SHALL BE ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING ALL PHASES OF CONSTRUCTION UNTIL THE COMPLETION OF ALL CONSTRUCTION ACTIVITIES AND ALL DISTURBED AREAS HAVE BEEN STABILIZED. ADDITIONAL CONTROL DEVICES MAY BE REQUIRED DURING CONSTRUCTION IN ORDER TO CONTROL EROSION AND/OR OFFSITE SEDIMENTATION. ALL TEMPORARY CONTROL DEVICES SHALL BE REMOVED ONCE CONSTRUCTION IS COMPLETE AND THE SITE IS STABILIZED. 6. THE CONTRACTOR MUST TAKE NECESSARY ACTION THE CONTRACTOR MUST TAKE NECESSARY ACTION TO MINIMIZE THE TRACKING OF MUD ONTO PAVED ROADWAY(S) FROM CONSTRUCTION AREAS AND THE GENERATION OF DUST. THE CONTRACTOR SHALL DAILY REMOVE MUD/SOIL FROM PAVEMENT, AS MAY BE REQUIRED. 7. RESIDENTIAL SUBDIVISION REQUIRE EROSION RESIDENTIAL SUBDIVISION REQUIRE EROSION CONTROL FEATURES FOR INFRASTRUCTURE AS WELL AS FOR INDIVIDUAL LOT CONSTRUCTION. INDIVIDUAL PROPERTY OWNERS SHALL FOLLOW THESE PLANS DURING CONSTRUCTION OR OBTAIN APPROVAL OF AN INDIVIDUAL PLAN IN ACCORDANCE WITH S.C. REG. 72-300 ET SEQ. AND SCR100000. 8. TEMPORARY DIVERSION BERMS AND/OR DITCHES TEMPORARY DIVERSION BERMS AND/OR DITCHES WILL BE PROVIDED AS NEEDED DURING CONSTRUCTION TO PROTECT WORK AREAS FROM UPSLOPE RUNOFF AND/OR TO DIVERT SEDIMENT-LADEN WATER TO APPROPRIATE TRAPS OR STABLE OUTLETS. 9. ALL WATERS OF THE STATE (WoS), INCLUDING ALL WATERS OF THE STATE (WoS), INCLUDING WETLANDS, ARE TO BE FLAGGED OR OTHERWISE CLEARLY MARKED IN THE FIELD. A DOUBLE ROW OF SILT FENCE IS TO BE INSTALLED IN ALL AREAS WHERE A 50-FOOT BUFFER CAN'T BE MAINTAINED BETWEEN THE DISTURBED AREA AND ALL WoS. A 10-FOOT BUFFER SHOULD BE MAINTAINED BETWEEN THE LAST ROW OF SILT FENCE AND ALL WoS. 10. LITTER, CONSTRUCTION DEBRIS, OILS, FUELS, AND LITTER, CONSTRUCTION DEBRIS, OILS, FUELS, AND BUILDING PRODUCTS WITH SIGNIFICANT POTENTIAL FOR IMPACT (SUCH AS STOCKPILES OF FRESHLY TREATED LUMBER) AND CONSTRUCTION CHEMICALS THAT COULD BE EXPOSED TO STORMWATER MUST BE PREVENTED FROM BECOMING A POLLUTANT SOURCE IN STORMWATER DISCHARGES. 11. A COPY OF THE SWPPP, INSPECTION RECORDS, AND A COPY OF THE SWPPP, INSPECTION RECORDS, AND RAINFALL DATA MUST BE RETAINED AT THE CONSTRUCTION SITE OR A NEARBY LOCATION EASILY ACCESSIBLE DURING NORMAL BUSINESS HOURS, FROM THE DATE OF COMMENCEMENT OF CONSTRUCTION ACTIVITIES TO THE DATE THAT FINAL STABILIZATION IS REACHED. 12. INITIATE STABILIZATION MEASURES ON ANY EXPOSED INITIATE STABILIZATION MEASURES ON ANY EXPOSED STEEP SLOPE (3H:1V OR GREATER) WHERE LAND-DISTURBING ACTIVITIES HAVE PERMANENTLY OR TEMPORARILY CEASED, AND WILL NOT RESUME FOR A PERIOD OF 7 CALENDAR DAYS. 13. MINIMIZE THE DISCHARGE OF POLLUTANTS FROM MINIMIZE THE DISCHARGE OF POLLUTANTS FROM EQUIPMENT AND VEHICLE WASHING, WHEEL WASH WATER, AND OTHER WASH WATERS. WASH WATERS MUST BE TREATED IN A SEDIMENT BASIN OR ALTERNATIVE CONTROL THAT PROVIDES EQUIVALENT OR BETTER TREATMENT PRIOR TO DISCHARGE. 14. MINIMIZE THE DISCHARGE OF POLLUTANTS FROM MINIMIZE THE DISCHARGE OF POLLUTANTS FROM DEWATERING OF TRENCHES AND EXCAVATED AREAS. THESE DISCHARGES ARE TO BE ROUTED THROUGH APPROPRIATE BMPs (SEDIMENT BASIN, FILTER BAG, ETC.). 15. THE FOLLOWING DISCHARGES FROM SITES ARE THE FOLLOWING DISCHARGES FROM SITES ARE PROHIBITED: WASTEWATER FROM WASHOUT OF CONCRETE, UNLESS MANAGED BY AN APPROPRIATE CONTROL; WASTEWATER FROM WASHOUT AND CLEANOUT OF STUCCO, PAINT, FORM RELEASE OILS, CURING COMPOUNDS AND OTHER CONSTRUCTION MATERIALS; FUELS OILS, OR OTHER POLLUTANTS USED IN VEHICLE AND EQUIPMENT OPERATION AND MAINTENANCE; AND SOAPS OR SOLVENTS USED IN VEHICLE AND EQUIPMENT WASHING. 16. AFTER CONSTRUCTION ACTIVITIES HAVE BEGUN, AFTER CONSTRUCTION ACTIVITIES HAVE BEGUN, INSPECTIONS MUST BE CONDUCTED AT A MINIMUM OF AT LEAST ONCE EVERY CALENDAR WEEK AND MUST BE CONDUCTED UNTIL FINAL STABILIZATION IS REACHED ON ALL AREAS OF THE CONSTRUCTION SITE. 17. IF EXISTING BMPs NEED TO BE MODIFIED OR IF IF EXISTING BMPs NEED TO BE MODIFIED OR IF ADDITIONAL BMPs ARE NECESSARY TO COMPLY WITH THE REQUIREMENTS OF THIS PERMIT AND/OR SC'S WATER QUALITY STANDARDS, IMPLEMENTATION MUST BE COMPLETED BEFORE THE NEXT STORM EVENT WHENEVER PRACTICABLE. IF IMPLEMENTATION BEFORE THE NEXT STORM EVENT IS IMPRACTICABLE, THE SITUATION MUST BE DOCUMENTED IN THE SWPPP AND ALTERNATIVE BMPs MUST BE IMPLEMENTED AS SOON AS REASONABLY POSSIBLE. 18. A PRE-CONSTRUCTION CONFERENCE MUST BE HELD A PRE-CONSTRUCTION CONFERENCE MUST BE HELD FOR EACH CONSTRUCTION SITE WITH AN APPROVED ON-SITE SWPPP INSPECTION PRIOR TO THE IMPLEMENTATION OF CONSTRUCTION ACTIVITIES. FOR NON-LINEAR PROJECTS THAT DISTURB 10 ACRES OR MORE, THIS CONFERENCE MUST BE HELD ON-SITE UNLESS THE DEPARTMENT HAS APPROVED OTHERWISE.
AutoCAD SHX Text
- NEW 12" WATER LINE
AutoCAD SHX Text
- NEW FIRE HYDRANT
AutoCAD SHX Text
- NEW GATE VALVE
AutoCAD SHX Text
- VALVE MARKER
AutoCAD SHX Text
VM
AutoCAD SHX Text
JULY 21, 2025
AutoCAD SHX Text
- CENTER LINE DRAINAGE DITCH
FLAT-BOTTOM TRENCH DETAIL
V-SHAPED TRENCH DETAIL
SILT FENCE INSTALLATION
STANDARD DRAWING NO.
South Carolina Department of Health and Environmental Control
PLAN SYMBOL
DATE
South Carolina Department of Health and Environmental Control
South Carolina Department of Health and Environmental Control
PLAN SYMBOL
DATE
South Carolina Department of Health and Environmental Control
South Carolina Department of Health and Environmental Control
SEDIMENT TUBE SPACING
SEDIMENT TUBE INSTALLATION
PLAN SYMBOL
South Carolina Department of Health and Environmental Control
R E
E V
E S
V
IL
LE
W
A T
E R
L
IN
E
IM
P R
O V
E M
E N
T S
D O
R C
H E
S T
E R
C O
U N
T Y
W A
T E
R A
N D
S E
W E
R D
E P
A R
T M
E N
T
G02
E R
O S
IO
N
C O
N T
R O
L A
N D
N O
T E
S
AutoCAD SHX Text
MAXIMUM SPACING = 6 FT.
AutoCAD SHX Text
FILTER FABRIC
AutoCAD SHX Text
BACKFILL TRENCH WITH COMPACTED EARTH
AutoCAD SHX Text
COMPACTED EARTH
AutoCAD SHX Text
COMPACTED EARTH
AutoCAD SHX Text
FILTER FABRIC
AutoCAD SHX Text
6-IN.
AutoCAD SHX Text
6-IN.
AutoCAD SHX Text
24-IN. (MINIMUM)
AutoCAD SHX Text
24-IN. (MINIMUM)
AutoCAD SHX Text
6-IN.
AutoCAD SHX Text
RUNOFF
AutoCAD SHX Text
RUNOFF
AutoCAD SHX Text
RUNOFF
AutoCAD SHX Text
18-IN. TO 24-IN.
AutoCAD SHX Text
BURY FABRIC
AutoCAD SHX Text
USE EITHER FLAT-BOTTOM OR V-BOTTOM TRENCH SEE DETAILS
AutoCAD SHX Text
FILTER FABRIC
AutoCAD SHX Text
BURY FILTER FABRIC AT LEAST 12-INCHES
AutoCAD SHX Text
SILT FENCE
AutoCAD SHX Text SC-03 Page 1 of 2
AutoCAD SHX Text
1.25 LB./LINEAR FT. STEEL POSTS
AutoCAD SHX Text
HEAVY DUTY PLASTIC TIE FOR STEEL POSTS (RESTRICT TO TOP 8-INCHES OF FABRIC)
AutoCAD SHX Text
18-IN. TO 24-IN.
AutoCAD SHX Text
FEBRUARY 2014
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
SILT FENCE - GENERAL NOTES
AutoCAD SHX Text
1. Do not place silt fence across channels or in other areas subject to concentrated flows. Silt fence should not Do not place silt fence across channels or in other areas subject to concentrated flows. Silt fence should not be used as a velocity control BMP. Concentrated flows are any flows greater than 0.5 cfs. 2. Maximum sheet or overland flow path length to the silt fence shall be 100-feet. Maximum sheet or overland flow path length to the silt fence shall be 100-feet. 3. Maximum slope steepness (normal [perpendicular] to the fence line) shall be 2:1. Maximum slope steepness (normal [perpendicular] to the fence line) shall be 2:1. 4. Silt fence joints, when necessary, shall be completed by one of the following options: Silt fence joints, when necessary, shall be completed by one of the following options: - Wrap each fabric together at a support post with both ends fastened to the post, with a 1-foot Wrap each fabric together at a support post with both ends fastened to the post, with a 1-foot minimum overlap; - Overlap silt fence by installing 3-feet passed the support post to which the new silt fence roll is Overlap silt fence by installing 3-feet passed the support post to which the new silt fence roll is attached. Attach old roll to new roll with heavy-duty plastic ties; or, - Overlap entire width of each silt fence roll from one support post to the next support post. Overlap entire width of each silt fence roll from one support post to the next support post. 5. Attach filter fabric to the steel posts using heavy-duty plastic ties that are evenly spaced within the top Attach filter fabric to the steel posts using heavy-duty plastic ties that are evenly spaced within the top 8-inches of the fabric. 6. Install the silt fence perpendicular to the direction of the stormwater flow and place the silt fence the proper Install the silt fence perpendicular to the direction of the stormwater flow and place the silt fence the proper distance from the toe of steep slopes to provide sediment storage and access for maintenance and cleanout. 7. Install Silt Fence Checks (Tie-Backs) every 50-100 feet, dependent on slope, along silt fence that is installed Install Silt Fence Checks (Tie-Backs) every 50-100 feet, dependent on slope, along silt fence that is installed with slope and where concentrated flows are expected or are documented along the proposed/installed silt fence.
AutoCAD SHX Text
HEAVY DUTY PLASTIC TIES
AutoCAD SHX Text
FILTER FABRIC
AutoCAD SHX Text
HEAVY DUTY PLASTIC TIES
AutoCAD SHX Text
SF
AutoCAD SHX Text
SF
AutoCAD SHX Text SC-03 PAGE 2 of 2
AutoCAD SHX Text
STANDARD DRAWING NO.
AutoCAD SHX Text
FEBRUARY 2014
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
SILT FENCE - POST REQUIREMENTS
AutoCAD SHX Text
1. Silt Fence posts must be 48-inch long steel posts that meet, at a minimum, Silt Fence posts must be 48-inch long steel posts that meet, at a minimum, the following physical characteristics. - Composed of a high strength steel with a minimum yield strength of Composed of a high strength steel with a minimum yield strength of 50,000 psi. - Include a standard "T" section with a nominal face width of 1.38-inches Include a standard "T" section with a nominal face width of 1.38-inches and a nominal "T" length of 1.48-inches. - Weigh 1.25 pounds per foot ( 8%) Weigh 1.25 pounds per foot (± 8%)2. Posts shall be equipped with projections to aid in fastening of filter fabric. Posts shall be equipped with projections to aid in fastening of filter fabric. 3. Steel posts may need to have a metal soil stabilization plate welded near the Steel posts may need to have a metal soil stabilization plate welded near the bottom when installed along steep slopes or installed in loose soils. The plate should have a minimum cross section of 17-square inches and be composed of 15 gauge steel, at a minimum. The metal soil stabilization plate should be completely buried. 4. Install posts to a minimum of 24-inches. A minimum height of 1- to 2- Install posts to a minimum of 24-inches. A minimum height of 1- to 2- inches above the fabric shall be maintained, and a maximum height of 3 feet shall be maintained above the ground. 5. Post spacing shall be at a maximum of 6-feet on center.Post spacing shall be at a maximum of 6-feet on center.
AutoCAD SHX Text
SILT FENCE - FABRIC REQUIREMENTS
AutoCAD SHX Text
1. Silt fence must be composed of woven geotextile filter fabric that consists of Silt fence must be composed of woven geotextile filter fabric that consists of the following requirements: - Composed of fibers consisting of long chain synthetic polymers of at Composed of fibers consisting of long chain synthetic polymers of at least 85% by weight of polyolefins, polyesters, or polyamides that are formed formed into a network such that the filaments or yarns retain dimensional stability stability relative to each other; - Free of any treatment or coating which might adversely alter its physical Free of any treatment or coating which might adversely alter its physical properties after installation; - Free of any defects or flaws that significantly affect its physical and/or Free of any defects or flaws that significantly affect its physical and/or filtering properties; and, - Have a minimum width of 36-inches. Have a minimum width of 36-inches. 2. Use only fabric appearing on SC DOT's Qualified Products Listing (QPL), Use only fabric appearing on SC DOT's Qualified Products Listing (QPL), Approval Sheet #34, meeting the requirements of the most current edition of the SC DOT Standard Specifications for Highway Construction. 3. 12-inches of the fabric should be placed within excavated trench and toed in 12-inches of the fabric should be placed within excavated trench and toed in when the trench is backfilled. 4. Filter Fabric shall be purchased in continuous rolls and cut to the length of Filter Fabric shall be purchased in continuous rolls and cut to the length of the barrier to avoid joints. 5. Filter Fabric shall be installed at a minimum of 24-inches above the ground.Filter Fabric shall be installed at a minimum of 24-inches above the ground.
AutoCAD SHX Text
SILT FENCE
AutoCAD SHX Text
1. The key to functional silt fence is weekly inspections, routine maintenance, and The key to functional silt fence is weekly inspections, routine maintenance, and regular sediment removal. 2. Regular inspections of silt fence shall be conducted once every calendar week Regular inspections of silt fence shall be conducted once every calendar week and, as recommended, within 24-hours after each rainfall even that produces 1/2-inch or more of precipitation. 3. Attention to sediment accumulations along the silt fence is extremely important. Attention to sediment accumulations along the silt fence is extremely important. Accumulated sediment should be continually monitored and removed when necessary. 4. Remove accumulated sediment when it reaches 1/3 the height of the silt Remove accumulated sediment when it reaches 1/3 the height of the silt fence. 5. Removed sediment shall be placed in stockpile storage areas or spread thinly Removed sediment shall be placed in stockpile storage areas or spread thinly across disturbed area. Stabilize the removed sediment after it is relocated. 6. Check for areas where stormwater runoff has eroded a channel beneath the Check for areas where stormwater runoff has eroded a channel beneath the silt fence, or where the fence has sagged or collapsed due to runoff overtopping the silt fence. Install checks/tie-backs and/or reinstall silt fence, as necessary. 7. Check for tears within the silt fence, areas where silt fence has begun to Check for tears within the silt fence, areas where silt fence has begun to decompose, and for any other circumstance that may render the silt fence ineffective. Removed damaged silt fence and reinstall new silt fence immediately. 8. Silt fence should be removed within 30 days after final stabilization is achieved Silt fence should be removed within 30 days after final stabilization is achieved and once it is removed, the resulting disturbed area shall be permanently stabilized.
AutoCAD SHX Text
SILT FENCE - INSPECTION & MAINTENANCE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CONSTRUCTION ENTRANCE
AutoCAD SHX Text SC-06 PAGE 1 of 2
AutoCAD SHX Text
STANDARD DRAWING NO.
AutoCAD SHX Text
FEBRUARY 2014
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
MIN.
AutoCAD SHX Text
6-INCH
AutoCAD SHX Text
100-FT. MIN.
AutoCAD SHX Text
24-FT. MIN.
AutoCAD SHX Text
AVERAGE STONE DIAMETER
AutoCAD SHX Text
PUBLIC ROAD
AutoCAD SHX Text
OF 2 TO 3-INCHES
AutoCAD SHX Text
WITH A 6-INCH MINIMUM DEPTH
AutoCAD SHX Text
UNDERLYING NON-WOVEN GEOTEXTILE FABRIC
AutoCAD SHX Text
EDGES SHALL BE TAPERED OUT
AutoCAD SHX Text
TOWARDS ROAD TO PREVENT
AutoCAD SHX Text
TRACKING OF MUD ON THE EDGES
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
SPECIFICATION
AutoCAD SHX Text
ROCK PAD THICKNESS
AutoCAD SHX Text
ROCK PAD WIDTH
AutoCAD SHX Text
ROCK PAD LENGTH
AutoCAD SHX Text
ROCK PAD STONE SIZE
AutoCAD SHX Text
6 INCHES
AutoCAD SHX Text
24 FEET
AutoCAD SHX Text
D = 2-3 INCHES
AutoCAD SHX Text
100 FEET
AutoCAD SHX Text SC-06 PAGE 2 of 2
AutoCAD SHX Text
STANDARD DRAWING NO.
AutoCAD SHX Text
FEBRUARY 2014
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
CONSTRUCTION ENTRANCE - GENERAL NOTES
AutoCAD SHX Text
1. Stabilized construction entrances should be used at all points Stabilized construction entrances should be used at all points where traffic will egress/ingress a construction site onto a public road or any impervious surfaces, such as parking lots. 2. Install a non-woven geotextile fabric prior to placing any Install a non-woven geotextile fabric prior to placing any stone. 3. Install a culvert pipe across the entrance when needed to Install a culvert pipe across the entrance when needed to provide positive drainage. 4. The entrance shall consist of 2-inch to 3-inch D50 stone The entrance shall consist of 2-inch to 3-inch D50 stone placed at a minimum depth of 6-inches. 5. Minimum dimensions of the entrance shall be 24-feet wide by Minimum dimensions of the entrance shall be 24-feet wide by 100-feet long, and may be modified as necessary to accommodate site constraints. 6. The edges of the entrance shall be tapered out towards the The edges of the entrance shall be tapered out towards the road to prevent tracking at the edge of the entrance. 7. Divert all surface runoff and drainage from the stone pad to Divert all surface runoff and drainage from the stone pad to a sediment trap or basin or other sediment trapping structure. 8. Limestone may not be used for the stone pad.Limestone may not be used for the stone pad.
AutoCAD SHX Text
1. The key to functional construction entrances is weekly The key to functional construction entrances is weekly inspections, routine maintenance, and regular sediment removal. 2. Regular inspections of construction entrances shall be Regular inspections of construction entrances shall be conducted once every calendar week and, as recommended, within 24-hours after each rainfall even that produces 1/2-inch or more of precipitation. 3. During regular inspections, check for mud and sediment During regular inspections, check for mud and sediment buildup and pad integrity. Inspection frequencies may need to be more frequent during long periods of wet weather. 4. Reshape the stone pad as necessary for drainage and runoff Reshape the stone pad as necessary for drainage and runoff control. 5. Wash or replace stones as needed and as directed by site inspector. The stone in the entrance should be washed or replaced whenever the entrance fails to reduce the amount of mud being carried off-site by vehicles. Frequent washing will extend the useful life of stone pad. 6. Immediately remove mud and sediment tracked or washed Immediately remove mud and sediment tracked or washed onto adjacent impervious surfaces by brushing or sweeping. Flushing should only be used when the water can be discharged to a sediment trap or basin. 7. During maintenance activities, any broken pavement should be During maintenance activities, any broken pavement should be repaired immediately. 8. Construction entrances should be removed after the site has Construction entrances should be removed after the site has reached final stabilization. Permanent vegetation should replace areas from which construction entrances have been removed, unless area will be converted to an impervious surface to serve post-construction.
AutoCAD SHX Text
CONSTR. ENTRANCE - INSPECTION & MAINTENANCE
AutoCAD SHX Text
CONSTRUCTION ENTRANCE
AutoCAD SHX Text
DATE
AutoCAD SHX Text SC-05 PAGE 1 of 2
AutoCAD SHX Text
STANDARD DRAWING NO.
AutoCAD SHX Text
FEBRUARY 2014
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text 2" x 2" wood stakes or 1.25 #/ft Steel Post
AutoCAD SHX Text 2.0' Minimum
AutoCAD SHX Text 2.0' Spacing (Typical) Continuous Along Tube
AutoCAD SHX Text 48" Minimum Length
AutoCAD SHX Text
FLOW
AutoCAD SHX Text Stakes Placed at 2' Minimum Spacing
AutoCAD SHX Text
MAX. SEDIMENT TUBE SPACING
AutoCAD SHX Text
SLOPE
AutoCAD SHX Text 4%
AutoCAD SHX Text 3%
AutoCAD SHX Text 2%
AutoCAD SHX Text
LESS THAN 2%
AutoCAD SHX Text
50-FEET
AutoCAD SHX Text
40-FEET
AutoCAD SHX Text
30-FEET
AutoCAD SHX Text
25-FEET
AutoCAD SHX Text 5%
AutoCAD SHX Text 6%
AutoCAD SHX Text
GREATER THAN 6%
AutoCAD SHX Text
150-FEET
AutoCAD SHX Text
100-FEET
AutoCAD SHX Text
75-FEET
AutoCAD SHX Text
SEDIMENT TUBES
AutoCAD SHX Text
DATE
AutoCAD SHX Text SC-05 PAGE 2 of 2
AutoCAD SHX Text
STANDARD DRAWING NO.
AutoCAD SHX Text
FEBRUARY 2014
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
SEDIMENT TUBES
AutoCAD SHX Text
SEDIMENT TUBES - GENERAL NOTES
AutoCAD SHX Text
1. Sediment tubes may be installed along contours, in drainage Sediment tubes may be installed along contours, in drainage conveyance channels, and around inlets to help prevent off-site discharge of sediment-laden stormwater runoff. 2. Sediment tubes are elongated tubes of compacted geotextiles, Sediment tubes are elongated tubes of compacted geotextiles, curled excelsior wood, natural coconut fiber, or hardwood mulch. Straw, pine needle, and leaf mulch-filled sediment tubes are not permitted. 3. The outer netting of the sediment tube should consist of The outer netting of the sediment tube should consist of seamless, high-density polyethylene photodegradable materials treated with ultraviolet stabilizers or a seamless, high-density polyethylene non-degradable material. 4. Sediment tubes, when used as checks within channels, should Sediment tubes, when used as checks within channels, should range between 18-inches and 24-inches depending on channel dimensions. Diameters outside this range may be allowed where necessary when approved. 5. Curled excelsior wood, or natural coconut products that are Curled excelsior wood, or natural coconut products that are rolled up to create a sediment tube are not allowed. 6. Sediment tubes should be staked using wooden stakes (2-inch Sediment tubes should be staked using wooden stakes (2-inch X 2-inch) or steel posts (standard "U" or "T" sections with a minimum weight of 1.25 pounds per foot) at a minimum of 48-inches in length placed on 2-foot centers. 7. Install all sediment tubes to ensure that no gaps exist Install all sediment tubes to ensure that no gaps exist between the soil and the bottom of the tube. Manufacturer's recommendations should always be consulted before installation. 8. The ends of adjacent sediment tubes should be overlapped The ends of adjacent sediment tubes should be overlapped 6-inches to prevent flow and sediment from passing through the field joint. 9. Sediment tubes should not be stacked on top of one another, Sediment tubes should not be stacked on top of one another, unless recommended by manufacturer. 10. Each sediment tube should be installed in a trench with a Each sediment tube should be installed in a trench with a depth equal to 1/5 the diameter of the sediment tube. 11. Sediment tubes should continue up the side slopes a minimum Sediment tubes should continue up the side slopes a minimum of 1-foot above the design flow depth of the channel. 12. Install stakes at a diagonal facing incoming runoff.
AutoCAD SHX Text
1. The key to functional sediment tubes is weekly inspections, The key to functional sediment tubes is weekly inspections, routine maintenance, and regular sediment removal. 2. Regular inspections of sediment tubes shall be conducted once Regular inspections of sediment tubes shall be conducted once every calendar week and, as recommended, within 24-hours after each rainfall even that produces 1/2-inch or more of precipitation. 3. Attention to sediment accumulations in front of the sediment Attention to sediment accumulations in front of the sediment tube is extremely important. Accumulated sediment should be continually monitored and removed when necessary. 4. Remove accumulated sediment when it reaches 1/3 the height Remove accumulated sediment when it reaches 1/3 the height of the sediment tube. 5. Removed sediment shall be placed in stockpile storage areas or spread thinly across disturbed area. Stabilize the removed sediment after it is relocated. 6. Large debris, trash, and leaves should be removed from in Large debris, trash, and leaves should be removed from in front of tubes when found. 7. If erosion causes the edges to fall to a height equal to or If erosion causes the edges to fall to a height equal to or below the height of the sediment tube, repairs should be made immediately to prevent runoff from bypassing tube. 8. Sediment tubes should be removed after the contributing Sediment tubes should be removed after the contributing drainage area has been completely stabilized. Permanent vegetation should replace areas from which sediment tubes have been removed.
AutoCAD SHX Text
SEDIMENT TUBES - INSPECTION & MAINTENANCE
AutoCAD SHX Text
DATE
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text No. 29604
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
TOWN OF REEVESVILLE DORCHESTER COUNTY, SOUTH CAROLINA
AutoCAD SHX Text
235 DEMING WAY SUMMERVILLE, SC 29483 PHONE: (843) 832-0075 FAX: (843) 832-0073
AutoCAD SHX Text
DATE: PROJECT ENGINEER: DESIGN BY: DRAWN BY: CHECKED BY:
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
JUNE 2023 CR CR SL JC/OW
JULY 21, 2025
TEMPORARY STOCKPILE
South Carolina Department of Health and Environmental Control
DATE
TEMPORARY STOCKPILE AREA
R E
E V
E S
V
IL
LE
W
A T
E R
L
IN
E
IM
P R
O V
E M
E N
T S
D O
R C
H E
S T
E R
C O
U N
T Y
W A
T E
R A
N D
S E
W E
R D
E P
A R
T M
E N
T
G03
E R
O S
IO
N
C O
N T
R O
L A
N D
N O
T E
S
AutoCAD SHX Text SC-15 PAGE 1 of 1
AutoCAD SHX Text
STANDARD DRAWING NO.
AutoCAD SHX Text
FEBRUARY 2014
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text NOTES: 1. SILT FENCE TO EXTEND AROUND ENTIRE PERIMETER OF STOCKPILE, OR IF SILT FENCE TO EXTEND AROUND ENTIRE PERIMETER OF STOCKPILE, OR IF STOCKPILE AREA IS LOCATED ON/NEAR A SLOP THE SILT FENCE IS TO EXTEND ALONG CONTOURS OF THE DOWN-GRADIENT AREA. 2. IF STOCKPILE IS TO REMAIN FOR MORE THAN 14 DAYS, TEMPORARY IF STOCKPILE IS TO REMAIN FOR MORE THAN 14 DAYS, TEMPORARY STABILIZATION MEASURES MUST BE IMPLEMENTED. 3. SILT FENCE SHALL BE MAINTAINED UNTIL STOCKPILE AREA HAS EITHER BEEN SILT FENCE SHALL BE MAINTAINED UNTIL STOCKPILE AREA HAS EITHER BEEN REMOVED OR PERMANENTLY STABILIZED. 4. THE KEY TO FUNCTIONAL TEMPORARY STOCKPILE AREAS IS WEEKLY THE KEY TO FUNCTIONAL TEMPORARY STOCKPILE AREAS IS WEEKLY INSPECTIONS, ROUTINE MAINTENANCE, AND REGULAR SEDIMENT REMOVAL.
AutoCAD SHX Text 3:1
AutoCAD SHX Text 3:1
AutoCAD SHX Text
SILT FENCE (SEE DETAIL)
AutoCAD SHX Text
SOIL/SEDIMENT STOCKPILE AREA
AutoCAD SHX Text
ORIGINAL GROUND SURFACE
AutoCAD SHX Text
10" (TYP.)
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text No. 29604
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
TOWN OF REEVESVILLE DORCHESTER COUNTY, SOUTH CAROLINA
AutoCAD SHX Text
235 DEMING WAY SUMMERVILLE, SC 29483 PHONE: (843) 832-0075 FAX: (843) 832-0073
AutoCAD SHX Text
DATE: PROJECT ENGINEER: DESIGN BY: DRAWN BY: CHECKED BY:
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
JUNE 2023 CR CR SL JC/OW
AutoCAD SHX Text
JULY 21, 2025
SEEDING SCHEDULE (NON-WETLAND) SCHEDULE NO. COMMON SEED NAME APPLICATION RATE PLANTING DATES COMMON SEED NAME APPLICATION RATE PLANTING DATES APPLICATION RATE PLANTING DATES PLANTING DATES (lb/acre) TEMPORARY 1 Rye (grain) or 56 Sept 1 - March 15 Rye (grain) or 56 Sept 1 - March 15 56 Sept 1 - March 15 Sept 1 - March 15 Rye (oats) 75 75 2 Rye (grass) 50 Sept 1 - April 15Rye (grass) 50 Sept 1 - April 1550 Sept 1 - April 15Sept 1 - April 153 Browntop Millet or 40 Mar 1 - August 31Browntop Millet or 40 Mar 1 - August 3140 Mar 1 - August 31Mar 1 - August 31Japaneses Millet 40 40 NOTES 1. Add 3,000 LB/AC straw mulch. Add 3,000 LB/AC straw mulch. PERMANENT 1 Rye (grain) 10 Sept 1 - Nov 15 Rye (grain) 10 Sept 1 - Nov 15 10 Sept 1 - Nov 15 Sept 1 - Nov 15 Bahia Grass 40 40 Clover, Crimson (annual) 5 5 2 Browntop Millet 10 Mar 15 - Aug 31 Browntop Millet 10 Mar 15 - Aug 31 10 Mar 15 - Aug 31 Mar 15 - Aug 31 Bahia Grass 20 20 Common Bermuda (hulled) 6 6 Sericea Lespedeza 40 40 NOTES 1. Add 3,000 LB/AC ground course textured agricultural limestone. Add 3,000 LB/AC ground course textured agricultural limestone. 2. Add 1,000 LB/AC 10-10-10 fertilizer. Add 1,000 LB/AC 10-10-10 fertilizer. 3. Add 4,000 LB/AC straw mulch. Add 4,000 LB/AC straw mulch. Application Method Ground Slope Ground Slope Broadcast Seeding 0 - 2% 0 - 2% (Unmulched) Broadcast Seeding 2 - 10% 2 - 10% (Mulched) Hydroseeding Greater than 10% Greater than 10%Greater than 10%
E V
E S
V
IL
LE
W
A T
E R
L
IN
E
IM
P R
O V
E M
E N
T S
R E
E V
E S
S T
P
LA
N S
S T
A
+0
- 1 1+
D
O R
C H
E S
T E
R C
O U
N T
Y W
A T
E R
A N
D S
E W
E R
D E
P A
R T
M E
N T
C05REEVES ST
STA 5+00 - 11+00
AutoCAD SHX Text
REEVES STREET (S-18-18) 66' R/W
AutoCAD SHX Text 33' R/W
AutoCAD SHX Text 33' R/W
AutoCAD SHX Text
REEVES STREET (S-18-18) 66' R/W
AutoCAD SHX Text 33' R/W
AutoCAD SHX Text 33' R/W
AutoCAD SHX Text 33' R/W
AutoCAD SHX Text 33 R/W
AutoCAD SHX Text 33' R/W
AutoCAD SHX Text 33' R/W
AutoCAD SHX Text
SCDOT DOCKET 18.289
AutoCAD SHX Text
SCDOT DOCKET 18.289
AutoCAD SHX Text D
AutoCAD SHX Text Y
AutoCAD SHX Text H
AutoCAD SHX Text
WV
AutoCAD SHX Text
WV
AutoCAD SHX Text W
AutoCAD SHX Text
MB
AutoCAD SHX Text
MB
AutoCAD SHX Text
IPF 5/8" RBR
AutoCAD SHX Text
IPF 5/8" RBR
AutoCAD SHX Text
15" RCP TOP: 106.23'
AutoCAD SHX Text
15" RCP TOP: 105.13'
AutoCAD SHX Text
48" RCP TOP: 103.11'
AutoCAD SHX Text
48" RCP TOP: 102.58'
AutoCAD SHX Text
48" RCP TOP: 102.17'
AutoCAD SHX Text
48" RCP TOP: 102.42'
AutoCAD SHX Text T
AutoCAD SHX Text
36" OAK
AutoCAD SHX Text
30" PINE
AutoCAD SHX Text
48" DBL GUM
AutoCAD SHX Text
24" COTTONWOOD
AutoCAD SHX Text
36" DBL MAPLE
AutoCAD SHX Text
24" GUM
AutoCAD SHX Text
18" OAK
AutoCAD SHX Text
24" OAK
AutoCAD SHX Text
TMS# 031-00-00-042 STUART A & JENNIFER SUSAN BURT SKOTNICKI 109 REEVES STREET
AutoCAD SHX Text
TMS# 043-00-00-109 MATTHEW & JENNIFER D GRUBER REEVES STREET
AutoCAD SHX Text
TMS# 043-03-00-034 DICKIE & EDYE GRAVES REEVES 106 REEVES STREET
AutoCAD SHX Text
TMS# 043-00-00-110 MATTHEW & JENNIFER D GRUBER 211 REEVES STREET
AutoCAD SHX Text
TMS# 043-00-00-003 AUBREY MORELAND 224 REEVES STREET
AutoCAD SHX Text
STA 10+44 END HDD BEGIN RJ PIPING 1-8" RJ BEND
AutoCAD SHX Text
STA 5+44 1-8" RJ BEND END RJ PIPING BEGIN HDD
AutoCAD SHX Text
STA 4+27 END RJ PIPING
AutoCAD SHX Text
SILT FENCE (TYP)
AutoCAD SHX Text STA 10+50 1-8"x6" TEE 2 LF OF 6" RJ DIP 1-6" GATE VALVE W/ VALVE BOX 2 LF OF 6" RJ DIP 1-FIRE HYDRANT ASSEMBLY
AutoCAD SHX Text
STA 4+07 1-8" 45° BEND
AutoCAD SHX Text
NEW "SERVICE 34"SERVICE LINE (TYP)
AutoCAD SHX Text
EXST. 48" RCP
AutoCAD SHX Text
N8W C900 DR18 (TYP)
AutoCAD SHX Text
STA 4+04 1-8" 45° BEND
AutoCAD SHX Text
6W (TO BE ABANDONED) NOTE 2
AutoCAD SHX Text
STA 10+84 END RJ PIPE
AutoCAD SHX Text
STA 5+04 BEGIN RJ PIPE
AutoCAD SHX Text
BEAR BRANCH
AutoCAD SHX Text
BEAR BRANCH
AutoCAD SHX Text
STA 5+44 1-8" RJ BEND END RJ PIPING BEGIN HDD
AutoCAD SHX Text
STA 10+44 END HDD BEGIN RJ PIPING 1-8" RJ BEND
AutoCAD SHX Text
EXISTING GRADE
AutoCAD SHX Text
EXISTING 48" RCP
AutoCAD SHX Text
20.0' MIN.
AutoCAD SHX Text
42" MIN.
AutoCAD SHX Text
42" MIN.
AutoCAD SHX Text
TOWN OF REEVESVILLE DORCHESTER COUNTY, SOUTH CAROLINA
AutoCAD SHX Text
235 DEMING WAY SUMMERVILLE, SC 29483 PHONE: (843) 832-0075 FAX: (843) 832-0073
AutoCAD SHX Text
DATE: PROJECT ENGINEER: DESIGN BY: DRAWN BY: CHECKED BY:
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
JUNE 2023 CR CR SL/MCM JC/OW
AutoCAD SHX Text
JULY 21, 2025
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX Text S
AutoCAD SHX Text No. 29604
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text O
AutoCAD SHX Text O
AutoCAD SHX Text C
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text S
AutoCAD SHX Text
SC GRID
AutoCAD SHX Text 1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 inch = ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1 inch = 5 ft.
AutoCAD SHX Text
( IN FEET )
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 2.5
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
E V
E S
V
IL
LE
W
A T
E R
L
IN
E
IM
P R
O V
E M
E N
T S
S T
A N
D A
R D
D E
T A
IL
S
D O
R C
H E
S T
E R
C O
U N
T Y
W A
T E
R A
N D
S E
W E
R D
E P
A R
T M
E N
T
D01
AutoCAD SHX Text
TOWN OF REEVESVILLE DORCHESTER COUNTY, SOUTH CAROLINA
AutoCAD SHX Text
235 DEMING WAY SUMMERVILLE, SC 29483 PHONE: (843) 832-0075 FAX: (843) 832-0073
AutoCAD SHX Text
DATE: PROJECT ENGINEER: DESIGN BY: DRAWN BY: CHECKED BY:
AutoCAD SHX Text
DRAWING NUMBER
AutoCAD SHX Text
REV
AutoCAD SHX Text
DATE
AutoCAD SHX Text
ISSUED FOR
AutoCAD SHX Text
JUNE 2023 CR CR SL/MCM JC/OW
AutoCAD SHX Text
JULY 21, 2025
AutoCAD SHX Text S
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text L
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text P
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text C
AutoCAD SHX Text H
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text O
AutoCAD SHX…