ATTACHMENT B- DRAWINGS.pdf
PDF 4 MB Posted
- Attached to
- Bldg. 3870 Interior Renovations Federal contract opportunity
- Solicitation number
- N4008523R2548
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF30 Amend1 23F2548 5-24.pdf | ||
| ATTACHMENT I- ACKNOWLEDGE OF AMENDMENTS.pdf | ||
| 23R2548 General Requirements.pdf | ||
| ATTACHMENT H-SOLICITATION PROVISIONS.pdf | ||
| ATTACHMENT G - Price Proposal Form.pdf | ||
| ATTACHMENT A- SPECIFICATIONS.pdf | ||
| ATTACHMENT D- SECNAV 5512.pdf | ||
| ATTACHMENT E- ONE DAY PASS FORM.pdf | ||
| ATTACHMENT C- WAGE DETERMINATION.pdf | ||
| ATTACHMENT F- PPI TEMPLATE.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
G-100
INTERIOR RENOVATIONS
SURFACE WARFARE SCHOOLS COMMAND
BUILDING 3870 ° JEB LITTLE CREEK, VIRGINIA
NAVAL FACILITIES ENGINEERING COMMAND ~ MID-ATLANTIC
PUBLIC WORKS DEPARTMENT LITTLE CREEK-FORT STORY
FACILITIES ENGINEERING AND ACQUISITION DIVISION
VICINITY MAP SYMBOLS LEGEND
ABBREVSLOCATION MAP
VICINITY MAP SYMBOLS LEGEND
ABBREVSLOCATION MAP
LIST OF SHEETSBUILDING CODES GENERAL NOTESVICINITY MAP SYMBOLS LEGEND
ABBREVSLOCATION MAP
B2 DETAIL OR SECTION TITLE
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
AutoCAD SHX Text
TITLE SHEET
AutoCAD SHX Text
KAF
AutoCAD SHX Text
KAF
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12863200
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text DETAIL, SECTION, OR ELEVATION NUMBER. NUMBER REFERENCES GRID PLACEMENT ON SHEET WHICH DETAIL IS DRAWN.
AutoCAD SHX Text
SHEET ON WHICH DETAIL, SECTION, OR ELEVATION IS DRAWN
AutoCAD SHX Text
CARET SYMBOLIZES A PHOTOGRAPH OR INTERIOR ELEVATION.
AutoCAD SHX Text
SHADED ARROW SIGNIFIES A SECTION CUT OR EXTERIOR ELEVATION.
AutoCAD SHX Text MFR MANUFACTURER MANUFACTURER MPH MILES PER HOUR MILES PER HOUR OC ON CENTER ON CENTER PSF POUNDS PER SQ FT POUNDS PER SQ FT PSI POUNDS PER SQ IN POUNDS PER SQ IN REINF REINFORCING,-MENT REINFORCING,-MENT REQ'D REQUIRED REQUIRED SCHED SCHEDULE SCHEDULE SHT SHEET SHEET SPEC SPECIFICATION SPECIFICATION SQ SQUARE SQUARE T&B TOP & BOTTOM TOP & BOTTOM TYP TYPICAL TYPICAL VERT VERTICAL VERTICAL UON UNLESS OTHERWISE UNLESS OTHERWISE NOTED VDOT VIRGINIA DEPT OF VIRGINIA DEPT OF TRANSPORTATION W/ WITH WITH W/O WITHOUTWITHOUT
AutoCAD SHX Text ABBREVS ABBREVIATIONS ABBREVIATIONS ALUM ALUMINUM ALUMINUM CL CENTERLINE CENTERLINE CMU CONC MASONRY UNIT CONC MASONRY UNIT CONC CONCRETE CONCRETE DEPT DEPARTMENT DEPARTMENT or DIA DIAMETER DIM DIMENSION DIMENSION DWGS DRAWINGS DRAWINGS ELEV ELEVATION ELEVATION EXIST EXISTING EXISTING FED FEDERAL FEDERAL GALV GALVANIZED GALVANIZED KIP 1000 POUNDS 1000 POUNDS KSI KIPS PER SQ INCH KIPS PER SQ INCH KTR CONTRACTOR CONTRACTOR LB POUNDS POUNDS LONG LONGITUDINAL LONGITUDINAL MAX MAXIMUM MAXIMUM MIN MINIMUM MINIMUM
AutoCAD SHX Text SHEET(S) ON WHICH DETAIL, SECTION, ELEVATION, OR PHOTOGRAPH IS CALLED OUT [INCLUDE FIRST & ATYPICAL LOCATIONS]
AutoCAD SHX Text G-001, A-00#
AutoCAD SHX Text
BUILDING 3870
AutoCAD SHX Text DETAIL, SECTION, OR ELEVATION NUMBER. NUMBER REFERENCES GRID PLACEMENT ON SHEET WHICH DETAIL IS DRAWN.
AutoCAD SHX Text
SHEET ON WHICH DETAIL, SECTION, OR ELEVATION IS DRAWN
AutoCAD SHX Text
CARET SYMBOLIZES A PHOTOGRAPH OR INTERIOR ELEVATION.
AutoCAD SHX Text
SHADED ARROW SIGNIFIES A SECTION CUT OR EXTERIOR ELEVATION.
AutoCAD SHX Text MFR MANUFACTURER MANUFACTURER MPH MILES PER HOUR MILES PER HOUR OC ON CENTER ON CENTER PSF POUNDS PER SQ FT POUNDS PER SQ FT PSI POUNDS PER SQ IN POUNDS PER SQ IN REINF REINFORCING,-MENT REINFORCING,-MENT REQ'D REQUIRED REQUIRED SCHED SCHEDULE SCHEDULE SHT SHEET SHEET SPEC SPECIFICATION SPECIFICATION SQ SQUARE SQUARE T&B TOP & BOTTOM TOP & BOTTOM TYP TYPICAL TYPICAL VERT VERTICAL VERTICAL UON UNLESS OTHERWISE UNLESS OTHERWISE NOTED VDOT VIRGINIA DEPT OF VIRGINIA DEPT OF TRANSPORTATION W/ WITH WITH W/O WITHOUTWITHOUT
AutoCAD SHX Text ABBREVS ABBREVIATIONS ABBREVIATIONS ALUM ALUMINUM ALUMINUM CL CENTERLINE CENTERLINE CMU CONC MASONRY UNIT CONC MASONRY UNIT CONC CONCRETE CONCRETE DEPT DEPARTMENT DEPARTMENT or DIA DIAMETER DIM DIMENSION DIMENSION DWGS DRAWINGS DRAWINGS ELEV ELEVATION ELEVATION EXIST EXISTING EXISTING FED FEDERAL FEDERAL GALV GALVANIZED GALVANIZED KIP 1000 POUNDS 1000 POUNDS KSI KIPS PER SQ INCH KIPS PER SQ INCH KTR CONTRACTOR CONTRACTOR LB POUNDS POUNDS LONG LONGITUDINAL LONGITUDINAL MAX MAXIMUM MAXIMUM MIN MINIMUM MINIMUM
AutoCAD SHX Text SHEET(S) ON WHICH DETAIL, SECTION, ELEVATION, OR PHOTOGRAPH IS CALLED OUT [INCLUDE FIRST & ATYPICAL LOCATIONS]
AutoCAD SHX Text G-001, A-00#
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
JEB LITTLE CREEK
AutoCAD SHX Text
NO.
AutoCAD SHX Text
DWG. NO.
AutoCAD SHX Text
SHEET TITLE
AutoCAD SHX Text G-100
AutoCAD SHX Text
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
NAVFAC
AutoCAD SHX Text 12869569
AutoCAD SHX Text
TITLE SHEET
AutoCAD SHX Text
AD101
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLITION PLANS
AutoCAD SHX Text
1. CONTRACTOR WILL COORDINATE WITH THE FEAD CONTRACTING CONTRACTOR WILL COORDINATE WITH THE FEAD CONTRACTING OFFICER TO ESTABLISH ACCEPTABLE ACCESS TO THE SITE. 2. CONSTRUCTION WORK AREAS AND PATHWAYS SHALL BE CLEANED CONSTRUCTION WORK AREAS AND PATHWAYS SHALL BE CLEANED DAILY. 3. ALL INDICATED DIMENSIONS AND EXISTING CONDITIONS ARE ALL INDICATED DIMENSIONS AND EXISTING CONDITIONS ARE CONSIDERED APPROXIMATE AND SHALL BE FIELD VERIFIED PRIOR TO ORDERING MATERIALS, FABRICATIONS OR BEGINNING CONSTRUCTION. 4. CONTRACTOR SHALL INVESTIGATE ALL EXISTING STRUCTURAL, CONTRACTOR SHALL INVESTIGATE ALL EXISTING STRUCTURAL, MECHANICAL AND ELECTRICAL FIELD CONDITIONS PRIOR TO COMMENCING ANY DEMOLITION AND/OR NEW CONSTRUCTION. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER PRIOR TO INTERRUPTING UTILITIES. 5. CONTRACTORS STORAGE AND PARKING AREA SHALL BE AS CONTRACTORS STORAGE AND PARKING AREA SHALL BE AS DIRECTED BY THE CONTRACTING OFFICER. 6. ALL ITEMS AND WORK NOT INDICATED TO BE EXISTING OR NOT IN ALL ITEMS AND WORK NOT INDICATED TO BE EXISTING OR NOT IN CONTRACT SHALL BE FURNISHED AND INSTALLED AS PART OF THE REQUIREMENTS OF THIS CONTRACT. 7. IT IS THE CONTRACTORS RESPONSIBILITY TO RECORD EXISTING IT IS THE CONTRACTORS RESPONSIBILITY TO RECORD EXISTING CONDITIONS PRIOR TO STARTING WORK. 8. THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS TO THE CONTRACTOR SHALL TAKE THE NECESSARY PRECAUTIONS TO PROTECT THE EXISTING UTILITIES AND ANY DAMAGE TO THE UTILITIES SHALL BE IMMEDIATELY REPAIRED AT THE CONTRACTORS EXPENSE. THE CONTRACTOR SHALL BE REQUIRED AND AGREES TO COMPLY WITH ALL THE PROVISIONS OF THE GOVERNMENT, STATE AND UTILITY FOR UNDERGROUND DAMAGE PREVENTION AND HEREBY AGREES TO HOLD THE GOVERNMENT HARMLESS AGAINST ANY LOSS, DAMAGES AND CLAIMS OF ANY NATURE WHATSOEVER ARISING OUT OF FAILURE TO COMPLY WITH SAID PROVISIONS
AutoCAD SHX Text MFR MANUFACTURER MANUFACTURER MPH MILES PER HOUR MILES PER HOUR OC ON CENTER ON CENTER PSF POUNDS PER SQ FT POUNDS PER SQ FT PSI POUNDS PER SQ IN POUNDS PER SQ IN REINF REINFORCING,-MENT REINFORCING,-MENT REQ'D REQUIRED REQUIRED SCHED SCHEDULE SCHEDULE SHT SHEET SHEET SPEC SPECIFICATION SPECIFICATION SQ SQUARE SQUARE T&B TOP & BOTTOM TOP & BOTTOM TYP TYPICAL TYPICAL VERT VERTICAL VERTICAL UON UNLESS OTHERWISE UNLESS OTHERWISE NOTED VDOT VIRGINIA DEPT OF VIRGINIA DEPT OF TRANSPORTATION W/ WITH WITH W/O WITHOUTWITHOUT
AutoCAD SHX Text ABBREVS ABBREVIATIONS ABBREVIATIONS ALUM ALUMINUM ALUMINUM CL CENTERLINE CENTERLINE CMU CONC MASONRY UNIT CONC MASONRY UNIT CONC CONCRETE CONCRETE DEPT DEPARTMENT DEPARTMENT or DIA DIAMETER DIM DIMENSION DIMENSION DWGS DRAWINGS DRAWINGS ELEV ELEVATION ELEVATION EXIST EXISTING EXISTING FED FEDERAL FEDERAL GALV GALVANIZED GALVANIZED KIP 1000 POUNDS 1000 POUNDS KSI KIPS PER SQ INCH KIPS PER SQ INCH KTR CONTRACTOR CONTRACTOR LB POUNDS POUNDS LONG LONGITUDINAL LONGITUDINAL MAX MAXIMUM MAXIMUM MIN MINIMUM MINIMUM
AutoCAD SHX Text DETAIL, SECTION, OR ELEVATION NUMBER. NUMBER REFERENCES GRID PLACEMENT ON SHEET WHICH DETAIL IS DRAWN.
AutoCAD SHX Text
SHEET ON WHICH DETAIL, SECTION, OR ELEVATION IS DRAWN
AutoCAD SHX Text
CARET SYMBOLIZES A PHOTOGRAPH OR INTERIOR ELEVATION.
AutoCAD SHX Text
SHADED ARROW SIGNIFIES A SECTION CUT OR EXTERIOR ELEVATION.
AutoCAD SHX Text SHEET(S) ON WHICH DETAIL, SECTION, ELEVATION, OR PHOTOGRAPH IS CALLED OUT [INCLUDE FIRST & ATYPICAL LOCATIONS]
AutoCAD SHX Text B2
AutoCAD SHX Text G-001
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text X/X" = 1'-0"
AutoCAD SHX Text G-001, A-00#
AutoCAD SHX Text
1. APPLICABLE BUILDING CODES AND REGULATIONS: APPLICABLE BUILDING CODES AND REGULATIONS: INTERNATIONAL EXISTING BUILDING CODE IBC 2018 VIRGINIA UNIFORM STATEWIDE BUILDING CODE SUPPLEMENTS 2. OCCUPANCY CLASSIFICATION: GROUP B PER IBC 308.5.1 OCCUPANCY CLASSIFICATION: GROUP B PER IBC 308.5.1 3. CONSTRUCTION TYPE: TYPE IICONSTRUCTION TYPE: TYPE IITYPE II
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text A-101
AutoCAD SHX Text
AutoCAD SHX Text
NEW WORK PLANS
AutoCAD SHX Text A-201
AutoCAD SHX Text
AutoCAD SHX Text
INTERIOR ELEVATIONS - MALE HEAD
AutoCAD SHX Text A-601
AutoCAD SHX Text
AutoCAD SHX Text
FINISH SCHEDULE
AutoCAD SHX Text
ARCHITECTURAL DRAWINGS
AutoCAD SHX Text A-202
AutoCAD SHX Text
AutoCAD SHX Text
INTERIOR ELEVATIONS - FEMALE HEAD
AutoCAD SHX Text M-001
AutoCAD SHX Text
AutoCAD SHX Text
LEGEND, ABBREVIATIONS, & GENERAL NOTES
AutoCAD SHX Text
MD101
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL DEMOLITION PLANS
AutoCAD SHX Text M-101
AutoCAD SHX Text
AutoCAD SHX Text
NEW WORK PLANS
AutoCAD SHX Text
MECHANICAL DRAWINGS
AutoCAD SHX Text
AutoCAD SHX Text E-001
AutoCAD SHX Text
AutoCAD SHX Text
LEGEND, ABBREVIATIONS, NOTES, & DETAIL
AutoCAD SHX Text
ED101
AutoCAD SHX Text
AutoCAD SHX Text
LIGHTING AND POWER PLANS - DEMOLITION
AutoCAD SHX Text E-101
AutoCAD SHX Text
AutoCAD SHX Text
LIGHTING AND POWER PLANS - NEW WORK
AutoCAD SHX Text
ELECTRICAL DRAWINGS
AutoCAD SHX Text E-501
AutoCAD SHX Text
DETAILS
AutoCAD SHX Text 12869570
AutoCAD SHX Text 12869571
AutoCAD SHX Text 12869572
AutoCAD SHX Text 12869573
AutoCAD SHX Text 12869574
AutoCAD SHX Text 12869575
AutoCAD SHX Text 12869576
AutoCAD SHX Text 12869577
AutoCAD SHX Text 12869578
AutoCAD SHX Text 12869579
AutoCAD SHX Text 12869580
AutoCAD SHX Text 12869581
OVERALL DEMOLITION CEILING PLAN
GRAPHIC SCALES
WORK NOTES - GENERAL
AD101
DEMOLITION WORK NOTES
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
DEMOLITION FLOOR PLAN - MALE & FEMALE HEADS DEMOLITION CEILING PLAN - MALE & FEMALE HEADS
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
1. COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE DISRUPTIONS TO ONGOING USE OF ADJACENT SPACES INSIDE BUILDING 3870 2. ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION DEVICES TO BE SALVAGED AND REINSTALLED IN OPERATING CONDITION 3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK REQUIREMENTS 4. REMOVE AND SALVAGE ALL CEILING MOUNTED PROJECTION UNITS REMOVE AND SALVAGE ALL CEILING MOUNTED PROJECTION UNITS PRIOR TO DEMOLITION
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
DEMOLITION PLANS
AutoCAD SHX Text
KAF
AutoCAD SHX Text
KAF
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869570
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
1. NO WORK IN THIS ROOM NO WORK IN THIS ROOM 2. SEE ENLARGED PLAN ON THIS SHEET SEE ENLARGED PLAN ON THIS SHEET 3. COMPLETELY REMOVE EXISTING ACOUSTIC PANEL CEILING INCLUDING COMPLETELY REMOVE EXISTING ACOUSTIC PANEL CEILING INCLUDING SUSPENSION GRID AND HANGERS ABOVE CEILING 4. COMPLETELY REMOVE EXISTING CARPET FLOORING AND RESILITENT COMPLETELY REMOVE EXISTING CARPET FLOORING AND RESILITENT BASE - DO NOT DISTURB EXISTING FINISHES BELOW CARPET, PREPARE FOR INSTALLATION OF NEW FLOORING AS SCHEDULED 5. COMPLETELY REMOVE EXISTING VINYL COMPOSITION TILE FLOORING COMPLETELY REMOVE EXISTING VINYL COMPOSITION TILE FLOORING AND RESILIENT BASE - PREPARE FLOOR SLAB AS REQUIRED TO RECEIVE NEW FLOORING AS SCHEDULED 6. EXISTING VINYL TILE FLOORING TO REMAIN UNDISTURBED (MASTIC EXISTING VINYL TILE FLOORING TO REMAIN UNDISTURBED (MASTIC BELOW IS SUSPECTED ACM) - PREPARE AS REQUIRED TO RECEIVE NEW FLOORING AS SCHEDULED 7. SCRAPE, PATCH, AND PREPARE EXISTING WALLS, DOORS, AND SCRAPE, PATCH, AND PREPARE EXISTING WALLS, DOORS, AND FRAMES FOR NEW PAINT FINISHES 8. REMOVE EXISTING PLUMBING FIXTURE, INCLUDING ASSOCIATED REMOVE EXISTING PLUMBING FIXTURE, INCLUDING ASSOCIATED EXPOSED SUPPLY AND DRAIN PIPING - SEE PLUMBING DRAWINGS 9. REMOVE EXISTING PARTITION / PRIVACY SCREEN REMOVE EXISTING PARTITION / PRIVACY SCREEN 10. REMOVE TILE FLOORING - PREPARE EXPOSED SLAB TO RECEIVE REMOVE TILE FLOORING - PREPARE EXPOSED SLAB TO RECEIVE NEW CERAMIC TILE FLOORING AS SCHEDULED 11. PREPARE EXISTING WALLS TO RECEIVE NEW CERAMIC TILE FINISH PREPARE EXISTING WALLS TO RECEIVE NEW CERAMIC TILE FINISH AS SCHEDULED, TYPICAL TO 8'-0" AFF 12. REMOVE EXISTING WINDOW SILL REMOVE EXISTING WINDOW SILL 13. REMOVE EXISTING LIGHT FIXTURE - SEE ELECTRICAL DRAWINGSREMOVE EXISTING LIGHT FIXTURE - SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
ROOM C2
AutoCAD SHX Text
ROOM C1
AutoCAD SHX Text
ROOM C15
AutoCAD SHX Text
ROOM C16
AutoCAD SHX Text
ROOM C9
AutoCAD SHX Text
CORRIDOR 2
AutoCAD SHX Text
VESTIBULE 1
AutoCAD SHX Text
VESTIBULE 2
AutoCAD SHX Text
CORRIDOR 1
AutoCAD SHX Text
PLAN
NORTH
OVERALL NEW WORK CEILING PLAN
WORK NOTES - GENERAL
A-101
NEW WORK NOTES
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
ENLARGED NEW WORK FLOOR PLAN ENLARGED NEW WORK CEILING PLAN
AutoCAD SHX Text K-4972-T
AutoCAD SHX Text
STANWELL
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-2030
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-2030
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4352
AutoCAD SHX Text
ANGLESEY
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4352
AutoCAD SHX Text
ANGLESEY
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
1. COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE DISRUPTIONS TO ONGOING USE OF ADJACENT SPACES INSIDE BUILDING 3870 2. ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION DEVICES TO BE SALVAGED AND REINSTALLED IN OPERATING CONDITION 3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW WORK REQUIREMENTS 4. REINSTALL AND RECONNECT EXISTING CEILING MOUNTED PROJECTION REINSTALL AND RECONNECT EXISTING CEILING MOUNTED PROJECTION UNITS IN IDENTICAL LOCATIONS IN NEW CEILING
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
NEW WORK PLANS
AutoCAD SHX Text
KAF
AutoCAD SHX Text
KAF
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869571
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
1. NO WORK IN THIS ROOM NO WORK IN THIS ROOM 2. SEE ENLARGED PLAN ON THIS SHEET SEE ENLARGED PLAN ON THIS SHEET 3. PROVIDE NEW ACOUSTIC PANEL CEILING INCLUDING SUSPENSION PROVIDE NEW ACOUSTIC PANEL CEILING INCLUDING SUSPENSION GRID AND HANGERS ABOVE CEILING 4. PROVIDE NEW CARPET TILE FLOORING AND RESILIENT BASE PROVIDE NEW CARPET TILE FLOORING AND RESILIENT BASE 5. PROVIDE NEW VINYL COMPOSITION TILE FLOORING AND RESILIENT PROVIDE NEW VINYL COMPOSITION TILE FLOORING AND RESILIENT BASE 6. PAINT WALLS, DOORS, AND FRAMES TO MATCH EXISTING COLOR PAINT WALLS, DOORS, AND FRAMES TO MATCH EXISTING COLOR AND GLOSS LEVEL 7. PAINT EXISTING EXPOSED CEILING INCLUDING PIPES AND OTHER PAINT EXISTING EXPOSED CEILING INCLUDING PIPES AND OTHER EQUIPMENT TO REMAIN 8. FUR EXISTING WALL WITH 3 " STEEL STUDS AT 24" ON CENTER FUR EXISTING WALL WITH 3 " STEEL STUDS AT 24" ON CENTER 12" STEEL STUDS AT 24" ON CENTER AND " CEMENT BOARD TO 8'-0" ABOVE FLOOR 12" CEMENT BOARD TO 8'-0" ABOVE FLOOR 9. PROVIDE HDPE TOILET PARTITION PROVIDE HDPE TOILET PARTITION 10. PROVIDE CERAMIC WALL TILE TO 8'-0" ABOVE FLOOR PROVIDE CERAMIC WALL TILE TO 8'-0" ABOVE FLOOR 11. PROVIDE HDPE SHOWER ENCLOSURE WITH SEAT PROVIDE HDPE SHOWER ENCLOSURE WITH SEAT 12. PROVIDE CERAMIC TILE FLOORING - SLOPE TO EXISTING DRAINS PROVIDE CERAMIC TILE FLOORING - SLOPE TO EXISTING DRAINS 13. FUR EXISTING WALL WITH 2 " STEEL STUDS AT 24" ON CENTER FUR EXISTING WALL WITH 2 " STEEL STUDS AT 24" ON CENTER 12" STEEL STUDS AT 24" ON CENTER AND " CEMENT BOARD TO 8'-0" ABOVE FLOOR 12" CEMENT BOARD TO 8'-0" ABOVE FLOOR 14. PROVIDE NEW LIGHT FIXTURES - SEE ELECTRICAL DRAWINGSPROVIDE NEW LIGHT FIXTURES - SEE ELECTRICAL DRAWINGS
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
ROOM C2
AutoCAD SHX Text
ROOM C1
AutoCAD SHX Text
ROOM C15
AutoCAD SHX Text
ROOM C16
AutoCAD SHX Text
ROOM C9
AutoCAD SHX Text
CORRIDOR 2
AutoCAD SHX Text
VESTIBULE 1
AutoCAD SHX Text
VESTIBULE 2
AutoCAD SHX Text
CORRIDOR 1
AutoCAD SHX Text A-201
AutoCAD SHX Text A3
AutoCAD SHX Text B1
AutoCAD SHX Text A1
AutoCAD SHX Text A-202
AutoCAD SHX Text D3
AutoCAD SHX Text A-201
AutoCAD SHX Text B3
AutoCAD SHX Text A-201
AutoCAD SHX Text C1
AutoCAD SHX Text B1
AutoCAD SHX Text A-202
AutoCAD SHX Text B2
AutoCAD SHX Text A2
AutoCAD SHX Text B1
AutoCAD SHX Text A1
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
FROM FLOOR TO 8'-0" AFF
B1
WORK NOTES - GENERAL
A-201
NEW WORK NOTES
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
A1 INTERIOR ELEVATION A3 INTERIOR ELEVATION
B1 INTERIOR ELEVATION B3 INTERIOR ELEVATION
C1 INTERIOR ELEVATION
AutoCAD SHX Text K-4972-T
AutoCAD SHX Text
STANWELL
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-12643
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-12643
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
ESTCODE
AutoCAD SHX Text
1. COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE DISRUPTIONS TO ONGOING USE OF ADJACENT SPACES INSIDE BUILDING 3870 2. ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION DEVICES TO BE SALVAGED AND REINSTALLED IN OPERATING CONDITION 3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW WORK REQUIREMENTS
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text
INTERIOR ELEVATIONS - MALE HEAD
AutoCAD SHX Text
KAF
AutoCAD SHX Text
KAF
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869572
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
1. CERAMIC TILE BASE CERAMIC TILE BASE 2. SLOPE TO EXISTING DRAIN - PROVIDE CERAMIC TILE FINISH SLOPE TO EXISTING DRAIN - PROVIDE CERAMIC TILE FINISH 3. EXISTING CURB TO REMAIN - PROVIDE CERAMIC TILE FINISH EXISTING CURB TO REMAIN - PROVIDE CERAMIC TILE FINISH 4. HDPE SHOWER ENCLOSURE HDPE SHOWER ENCLOSURE 5. FUR EXISTING WALL WITH 2 " STEEL STUDS AND " CEMENT BOARD FUR EXISTING WALL WITH 2 " STEEL STUDS AND " CEMENT BOARD 12" STEEL STUDS AND " CEMENT BOARD 12" CEMENT BOARD 6. FUR EXISTING WALL WITH 3 " STEEL STUDS AND " CEMENT BOARD FUR EXISTING WALL WITH 3 " STEEL STUDS AND " CEMENT BOARD 12" STEEL STUDS AND " CEMENT BOARD 12" CEMENT BOARD 7. PROVIDE CERAMIC TILE WALL FINISH TO 8'-0" ABOVE FLOOR PROVIDE CERAMIC TILE WALL FINISH TO 8'-0" ABOVE FLOOR 8. PAINT EXISTING PARTITION ABOVE CERAMIC TILE PAINT EXISTING PARTITION ABOVE CERAMIC TILE 9. PLUMBING FIXTURE - SEE PLUMBING DRAWINGS PLUMBING FIXTURE - SEE PLUMBING DRAWINGS 10. 36" GRAB BAR AT 36" AFF 36" GRAB BAR AT 36" AFF 11. 42" GRAB BAR AT 36" AFF 42" GRAB BAR AT 36" AFF 12. 30" X 42" TEMPERED GLASS MIRROR IN STAINLESS STEEL FRAME 30" X 42" TEMPERED GLASS MIRROR IN STAINLESS STEEL FRAME 13. HDPE TOILET STALL HDPE TOILET STALL 14. NOT USED NOT USED 15. HDPE SEAT HDPE SEAT 16. EACH SHOWER STALL TO INCLUDE THE FOLLOWING STAINLESS EACH SHOWER STALL TO INCLUDE THE FOLLOWING STAINLESS STEEL ACCESSORIES, LOCATIONS TO BE DETERMINED: (1) 24" TOWEL BAR (2) ROBE HOOKS (1) 24" SHELF 17. EXISTING DOOR AND FRAME BEYOND - PAINT TO MATCHEXISTING DOOR AND FRAME BEYOND - PAINT TO MATCH
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SHOWN DASHED
AutoCAD SHX Text
SHOWN DASHED
SHOWN DASHED
A-202
NEW WORK NOTES
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
A1 INTERIOR ELEVATION A3 INTERIOR ELEVATION
B1 INTERIOR ELEVATION B3 INTERIOR ELEVATION
D1 DETAIL
AutoCAD SHX Text K-12643
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-12643
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
C_LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
MODELNUMBER
AutoCAD SHX Text
TRADENAME
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
MATERIAL
AutoCAD SHX Text
1. COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE DISRUPTIONS TO ONGOING USE OF ADJACENT SPACES INSIDE BUILDING 3870 2. ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION DEVICES TO BE SALVAGED AND REINSTALLED IN OPERATING CONDITION 3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW WORK REQUIREMENTS
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/2"=1'-0"
AutoCAD SHX Text 1'
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text
INTERIOR ELEVATIONS - FEMALE HEAD
AutoCAD SHX Text
KAF
AutoCAD SHX Text
KAF
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869573
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text
1. CERAMIC TILE BASE CERAMIC TILE BASE 2. HDPE TOILET STALL HDPE TOILET STALL 3. FUR EXISTING WALL WITH 3 " STEEL STUDS AT 24" ON CENTER FUR EXISTING WALL WITH 3 " STEEL STUDS AT 24" ON CENTER 12" STEEL STUDS AT 24" ON CENTER AND " CEMENT BOARD 12" CEMENT BOARD 4. PROVIDE CERAMIC TILE WALL FINISH TO 8'-0" ABOVE FLOOR PROVIDE CERAMIC TILE WALL FINISH TO 8'-0" ABOVE FLOOR 5. NOT USED NOT USED 6. PLUMBING FIXTURE - SEE PLUMBING DRAWINGS PLUMBING FIXTURE - SEE PLUMBING DRAWINGS 7. 36" GRAB BAR AT 36" AFF 36" GRAB BAR AT 36" AFF 8. 42" GRAB BAR AT 36" AFF 42" GRAB BAR AT 36" AFF 9. 30" X 42" TEMPERED GLASS MIRROR IN STAINLESS STEEL FRAME 30" X 42" TEMPERED GLASS MIRROR IN STAINLESS STEEL FRAME 10. EXISTING DOOR AND FRAME BEYOND - PAINT TO MATCH EXISTING DOOR AND FRAME BEYOND - PAINT TO MATCH 11. TURN NEW CEILING UP AT WINDOW TO FORM POCKET TURN NEW CEILING UP AT WINDOW TO FORM POCKET 12. EXISTING CMU WALL EXISTING CMU WALL 13. 3 " STEEL STUD FRAMING AT 24" ON CENTER FROM FLOOR TO 3 " STEEL STUD FRAMING AT 24" ON CENTER FROM FLOOR TO 12" STEEL STUD FRAMING AT 24" ON CENTER FROM FLOOR TO NEW SUSPENDED GYPSUM BOARD CEILING 14. " CEMENT BOARD 12" CEMENT BOARD 15. CERAMIC TILE WALL FINISH AS SCHEDULED CERAMIC TILE WALL FINISH AS SCHEDULED 16. TERMINATE TILE WITH BULLNOSE EDGE OR METAL STRIP EDGE TERMINATE TILE WITH BULLNOSE EDGE OR METAL STRIP EDGE 17. CONTINUOUS SILICONE SEALANT CONTINUOUS SILICONE SEALANT 18. CONTINUE STEEL STUD FRAMING, CEMENT BOARD, AND CERAMIC CONTINUE STEEL STUD FRAMING, CEMENT BOARD, AND CERAMIC TILE WALL FINISH BENEATH WINDOW OPENING 19. PROVIDE NEW SLATE WINDOW SILL PROVIDE NEW SLATE WINDOW SILL 20. EXISTING WINDOW TO REMAINEXISTING WINDOW TO REMAIN
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1 1/2" = 1'-0"
AutoCAD SHX Text A-101
AutoCAD SHX Text 1-1/2"=1'-0"
AutoCAD SHX Text
AutoCAD SHX Text 6"
AutoCAD SHX Text 1'
1'-6"
A-601
NOTES
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
FINISH SCHEDULE
FINISH LEGEND
AutoCAD SHX Text
1. COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE DISRUPTIONS TO ONGOING USE OF ADJACENT SPACES INSIDE BUILDING 3870 2. ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION DEVICES TO BE SALVAGED AND REINSTALLED IN OPERATING CONDITION 3. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW WORK REQUIREMENTS 4. SCHEDULED FINISHES ARE INTENDED TO ILLUSTRATE DESIGN INTENT; SCHEDULED FINISHES ARE INTENDED TO ILLUSTRATE DESIGN INTENT; PRODUCTS BY ALTERNATE MANUFACTURERS MEETING PERFORMANCE SPECIFICATIONS AND SIMILAR IN SIZE AND APPEARANCE WILL BE ACCEPTED
AutoCAD SHX Text
FINISH SCHEDULE
AutoCAD SHX Text
KAF
AutoCAD SHX Text
KAF
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869574
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
1. PREPARE EXISTING FLOOR SURFACE AS REQUIRED FOR NEW PREPARE EXISTING FLOOR SURFACE AS REQUIRED FOR NEW CARPET 2. PREPARE EXISTING FLOOR SURFACE AS REQUIRED FOR NEW PREPARE EXISTING FLOOR SURFACE AS REQUIRED FOR NEW LUXURY VINYL TILE 3. DO NOT DISTURB EXISTING VINYL FLOOR TILE - FILL CRACKS DO NOT DISTURB EXISTING VINYL FLOOR TILE - FILL CRACKS AND VOIDS WITH LEVELING COMPOUND TO CREATE SMOOTH LEVEL SURFACE FOR NEW LUXURY VINYL TILE 4. PREPARE EXISTING WALL SURFACES AS REQUIRED FOR NEW PAINT PREPARE EXISTING WALL SURFACES AS REQUIRED FOR NEW PAINT 5. PAINT EXISTING DOORS AND FRAMES PT2 PAINT EXISTING DOORS AND FRAMES PT2 6. PREPARE EXISTING FLOOR SURFACE AS REQUIRED FOR NEW PREPARE EXISTING FLOOR SURFACE AS REQUIRED FOR NEW CERAMIC TILE 7. PREPARE EXISTING WALL SURFACES AS REQUIRED FOR NEW PREPARE EXISTING WALL SURFACES AS REQUIRED FOR NEW CERAMIC TILE 8. PROVIDE RESILIENT TRANSITION STRIP AT FLOOR FINISH PROVIDE RESILIENT TRANSITION STRIP AT FLOOR FINISH TRANSITIONS 9. PROVIDE MARBLE THRESHOLD AT DOOR TO CORRIDOR PROVIDE MARBLE THRESHOLD AT DOOR TO CORRIDOR 10. INSTALL NEW CEILING TO MATCH HIGHER LEVEL OF EXISTING TWO INSTALL NEW CEILING TO MATCH HIGHER LEVEL OF EXISTING TWO LEVEL CEILING
AutoCAD SHX Text
ROOM
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
BASE
AutoCAD SHX Text
WALLS
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
NOTES
AutoCAD SHX Text C1
AutoCAD SHX Text
CARPET
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
PT1
AutoCAD SHX Text
APC
AutoCAD SHX Text 1, 4, 5, 8
AutoCAD SHX Text C2
AutoCAD SHX Text
CARPET
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text C9
AutoCAD SHX Text
CARPET
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text C15
AutoCAD SHX Text
LVT1
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text 2, 4, 5, 8
AutoCAD SHX Text C16
AutoCAD SHX Text
LVT1
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text
CORRIDOR 1
AutoCAD SHX Text
LVT2
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text 3, 4, 5, 8
AutoCAD SHX Text
CORRIDOR 2
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text
VESTIBULE 1
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text 3, 4, 5, 8
AutoCAD SHX Text
VESTIBULE 2
AutoCAD SHX Text
RESILIENT
AutoCAD SHX Text
APC
AutoCAD SHX Text
MALE HEAD
AutoCAD SHX Text
CT 1
AutoCAD SHX Text
CT 2
AutoCAD SHX Text
CT 3
AutoCAD SHX Text
PT3
AutoCAD SHX Text 5, 6, 7, 9
AutoCAD SHX Text
FEMALE HEAD
AutoCAD SHX Text
CT 1
AutoCAD SHX Text
CT 2
AutoCAD SHX Text
CT 3
AutoCAD SHX Text
PT3
AutoCAD SHX Text CARPET: CARPET TILE SHAW ENCOUNTER COLLECTION STYLE 5T457 KEEN 57486 24" X 24" QUARTER TURN INSTALLATION LVT1: LUXURY VINYL TILE SHAW EON & AMALGAM COLLECTION STYLE 4113V UNCOVER 13114 20" X 20" QUARTER TURN INSTALLATION LVT2: LUXURY VINYL TILE SHAW UNVEIL COLLECTION STYLE 0601V FADED 01103 9" X 36" STAGGER INSTALLATION RESILIENT: RUBBER COVED ROLL BASE ARMSTRONG WALL BASE 4" FLAGSTONE R48FS APC: ACOUSTICAL PANEL CEILING ARMSTRONG CORTEGA WHITE ANGLED TEGULAR 24" X 24" X 15/16" PT1: EXISTING WALLS TO REMAIN EXISTING WALLS TO REMAIN GLIDDEN HIGH ENDURANCE PLUS EGGSHELL OYSTER WHITE PPG10-05 PT2: EXISTING DOORS AND FRAMES TO REMAIN EXISTING DOORS AND FRAMES TO REMAIN GLIDDEN HIGH ENDURANCE PLUS SEMI-GLOSS MATCH EXISTING DOOR AND FRAME COLOR PT3: EXISTING EXPOSED SURFACES EXISTING EXPOSED SURFACES GLIDDEN PROFESSIONAL ULTRA-HIDE 440 WB READY MIX WHITE FLAT CT1: CERAMIC TILE FLOORING DALTILE REMINISCENT SERIES MEMENTO WHITE RM20 MOSAIC 2" X 2" X 1/4" CT2: CERAMIC TILE COVE BASE DALTILE REMINISCENT SERIES MEMENTO WHITE P36C9 6" X 12" CT3: CERAMIC WALL TILE DALTILE VITRUVIAN SERIES WHITE MATTE V V11 6" X 6" X 5/16"
AutoCAD SHX Text
LVT2
AutoCAD SHX Text
LVT2
AutoCAD SHX Text
LVT2
AutoCAD SHX Text
PT1
AutoCAD SHX Text
PT1
AutoCAD SHX Text
PT1
AutoCAD SHX Text
PT1
AutoCAD SHX Text
PT1
AutoCAD SHX Text
PT1
AutoCAD SHX Text
PT1
AutoCAD SHX Text
PT1
AutoCAD SHX Text 2, 4, 5, 8
AutoCAD SHX Text 2, 4, 5, 8
AutoCAD SHX Text 2, 4, 5, 8
AutoCAD SHX Text 5, 6, 7, 9
AutoCAD SHX Text 1, 4, 5, 8
1, 4, 5, 8, 10
M-001
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
MECHANICAL LEGEND MECHANICAL ABBREVIATIONS GENERAL MECHANICAL NOTESMECHANICAL PIPING LEGEND
MECHANICAL SYMBOLS
PLUMBING FIXTURE SCHEDULE
AutoCAD SHX Text
LEGEND, ABBREVIATIONS & GENERAL NOTES
AutoCAD SHX Text
CML
AutoCAD SHX Text
CML
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869575
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text AD AFF AP APD AHU BD BR BTUH C Cv CU CW CFM CLG CND COP CRAHU DB DDC DEG DX EAT ECM EER EF EFF ESP EWT EXST F FCU FD FT FTWG GPM HGT HP HR HW HX IAW IWG kW LAT LBS LV LWT MAU MAX MIN NC NO OA OAU OU PH PRS PSI RA RH RL RS RTU SA SEER SIM SP SQ TYP UH UOI V VFD W WB WPD °
AutoCAD SHX Text ACCESS DOOR ABOVE FINISHED FLOOR ACCESS PANEL AIR PRESSURE DROP AIR HANDLING UNIT BALANCING DAMPER BASEBOARD RADIATOR BRITISH THERMAL UNIT PER HOUR COMMON LOSS COEFFICIENT CONDENSING UNIT CHILLED WATER CUBIC FEET PER MINUTE CEILING CONDENSER COEFFICENT OF PERFORMANCE COMPUTER ROOM AIR HANDLING UNIT DRY BULB DIRECT DIGITAL CONTROL DEGREE DIRECT EXPANSION ENTERING AIR TEMPRATURE ELECTRONIC CONTROL MODULE ENERGY EFFICIENCY RATIO EXHAUST FAN EFFICIENCY EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FAN COIL UNIT FIRE DAMPER FEET FEET OF WATER GAUGE GALLONS PER MINUTE HEIGHT HEAT PUMP, HORSEPOWER HOUR HOT WATER HEAT EXCHANGER INCHES OF WATER GAUGE IN ACCORDANCE WITH KILOWATT LEAVING AIR TEMPERATURE POUNDS LOUVER LEAVING WATER TEMPERATURE MAKEUP AIR UNIT MAXIMUM MINIMUM NOISE CRITERIA, NORMALLY CLOSED NUMBER, NORMALLY OPEN OUTSIDE AIR OUTSIDE AIR UNIT OUTDOOR UNIT PHASE PRESSURE REDUCING STATION POUNDS PER SQUARE INCH RETURN AIR RELATIVE HUMIDITY REFRIGERANT LIQUID REFRIGERANT SUCTION ROOFTOP UNIT SUPPLY AIR SEASONAL ENERGY EFFICIENCY RATIO SIMILAR STATIC PRESSURE SQUARE TYPICAL UNIT HEATER UNLESS OTHERWISE INDICATED VOLTS VARIABLE FREQUENCY DRIVE WIDTH WET BULB WATER PRESSURE DROP DEGREES DIAMETER
AutoCAD SHX Text 12x10 OR 12/10
AutoCAD SHX Text
POINT OF DISCONNECTION
AutoCAD SHX Text
POINT OF CONNECTION
AutoCAD SHX Text T
AutoCAD SHX Text
TEMPERATURE SENSOR
AutoCAD SHX Text
SUPPLY DUCT, SUPPLY DUCT
AutoCAD SHX Text
RETURN DUCT, RETURN DUCT
AutoCAD SHX Text
DOWN/UP
AutoCAD SHX Text
DOWN/UP
AutoCAD SHX Text
1. THESE GENERAL MECHANICAL NOTES APPLY TO ALL MECHANICAL THESE GENERAL MECHANICAL NOTES APPLY TO ALL MECHANICAL DRAWINGS IN THIS SET. SHEET SPECIFIC NOTES ARE INDICATED ON EACH SHEET UNDER GENERAL SHEET NOTES. 2. PATCH ALL HOLES FROM REMOVAL OF PIPING, DUCTWORK, OR PATCH ALL HOLES FROM REMOVAL OF PIPING, DUCTWORK, OR EQUIPMENT TO MATCH ADJACENT CONSTRUCTION. 3. PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL PROVIDE ALL MATERIALS AND EQUIPMENT AND PERFORM ALL LABOR REQUIRED TO INSTALL COMPLETE AND OPERABLE MECHANICAL SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED AND AS REQUIRED BY CODE. 4. INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN INSTALL ALL MECHANICAL EQUIPMENT AND APPURTENANCES IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS, THIS CONTRACT'S DOCUMENTS, AND APPLICABLE CODES AND REGULATIONS. 5. PROVIDE VIBRATION ISOLATORS FOR ALL MECHANICAL EQUIPMENT PROVIDE VIBRATION ISOLATORS FOR ALL MECHANICAL EQUIPMENT TO PREVENT TRANSMISSION OF VIBRATION TO BUILDING STRUCTURE. 6. PROVIDE ACCESS PANELS IN WALLS AND CEILINGS, WHERE PROVIDE ACCESS PANELS IN WALLS AND CEILINGS, WHERE REQUIRED, TO SERVE FIRE DAMPERS, VALVES, SMOKE DETECTORS, AND OTHER CONCEALED MECHANICAL EQUIPMENT THAT REQUIRES ROUTINE MAINTENANCE. ACCESS PANELS SHALL BE LARGE ENOUGH TO ALLOW PROPER CLEARANCE FOR ACCESS DOORS. 7. ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK, PIPING, ALL OPENINGS IN FIRE WALLS DUE TO DUCTWORK, PIPING, CONDUIT, ETC., SHALL BE FIRE STOPPED. 8. EXISTING DUCT AND PIPING SIZES INDICATED ARE APPROXIMATE. EXISTING DUCT AND PIPING SIZES INDICATED ARE APPROXIMATE. FIELD VERIFY ALL DIMENSIONS. 9. LOCATE ALL NEW HORIZONTAL DUCTWORK ABOVE THE SUSPENDED LOCATE ALL NEW HORIZONTAL DUCTWORK ABOVE THE SUSPENDED CEILINGS UNLESS OTHERWISE INDICATED. 10. ALL 90 DEGREE RECTANGULAR MITERED DUCT ELBOWS IN THE ALL 90 DEGREE RECTANGULAR MITERED DUCT ELBOWS IN THE SUPPLY DUCTS SHALL HAVE TURNING VANES. 11. PROVIDE PIPE SLEEVES FOR ALL PIPING PENETRATIONS THRU PROVIDE PIPE SLEEVES FOR ALL PIPING PENETRATIONS THRU WALLS AND FLOORS. EACH PIPE SHALL BE SEPARATELY SLEEVED. PROVIDE CONTINUOUS SEALANT JOINT AROUND PIPE SLEEVE, BOTH SIDES OF WALL, WATERTIGHT. 12. PROVIDE P-TRAPS IN CONDENSATE DRAIN PIPING AT EACH AHU PROVIDE P-TRAPS IN CONDENSATE DRAIN PIPING AT EACH AHU UNLESS THE AHU IS EQUIPPED WITH AN INTERNAL TRAP. 13. MOUNT THERMOSTATS 48 INCHES ABOVE THE FINISHED FLOOR MOUNT THERMOSTATS 48 INCHES ABOVE THE FINISHED FLOOR UNLESS OTHERWISE INDICATED. REFER TO ELECTRICAL DRAWINGS FOR LOCATION OF LIGHT SWITCHES AND COORDINATE. 14. AFTER THE PIPING IS INSULATED, PROVIDE SETON BRAND OR AFTER THE PIPING IS INSULATED, PROVIDE SETON BRAND OR EQUAL FACTORY-FABRICATED PIPE LABELS WITH DIRECTION OF FLOW. PROVIDE AT 10 FOOT INTERVALS ON PIPING MAINS AND 5 FOOT INTERVALS ON THE BRANCH RUNOUTS FROM MAINS. PROVIDE ON THE FOLLOWING PIPING SYSTEM: HEATING HOT WATER CHILLED WATER CONDENSATE DRAIN
AutoCAD SHX Text
PIPING TO BE REMOVED
AutoCAD SHX Text
HWR
AutoCAD SHX Text
HWS
AutoCAD SHX Text
RL
AutoCAD SHX Text
HOT WATER RETURN PIPING
AutoCAD SHX Text
HOT WATER SUPPLY PIPING
AutoCAD SHX Text
CHILLED WATER RETURN PIPING
AutoCAD SHX Text
CHR
AutoCAD SHX Text
CHILLED WATER SUPPLY PIPING
AutoCAD SHX Text
CHS
AutoCAD SHX Text
DOMESTIC COLD WATER PIPING
AutoCAD SHX Text
REFRIGERANT LIQUID PIPING
AutoCAD SHX Text
CONDENSATE DRAIN PIPING
AutoCAD SHX Text D
AutoCAD SHX Text
NAME
AutoCAD SHX Text
DCW
AutoCAD SHX Text H
AutoCAD SHX Text
HUMIDITY SENSOR
AutoCAD SHX Text
AIR TERMINAL TAG WITH AIR FLOW (CFM)
AutoCAD SHX Text
RECTANGULAR DUCT DIMENSIONS (INCHES)
AutoCAD SHX Text
DOWNWARD DIRECTION OF SLOPED PIPING
AutoCAD SHX Text
STEAM TRAP
AutoCAD SHX Text
VACUUM BREAKER
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
BACKFLOW PREVENTER
AutoCAD SHX Text
RELIEF VALVE
AutoCAD SHX Text
3-WAY CONTROL VALVE
AutoCAD SHX Text
2-WAY CONTROL VALVE
AutoCAD SHX Text
DRAIN VALVE WITH HOSE CONNECTION
AutoCAD SHX Text
SQUARE HEAD BALANCING COCK
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
AUTOMATIC FLOW BALANCING VALVE
AutoCAD SHX Text
MANUAL FLOW CONTROL BALANCING VALVE
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text T
AutoCAD SHX Text C.O.
AutoCAD SHX Text
CLEAN OUT
AutoCAD SHX Text
SPRINKLER HEAD
AutoCAD SHX Text
VALVE IN VERT. PIPING
AutoCAD SHX Text
WYE STRAINER
AutoCAD SHX Text
STRAINER W/ BLOWDOWN VALVE
AutoCAD SHX Text
ECCENTRIC REDUCER
AutoCAD SHX Text
PIPE REDUCER
AutoCAD SHX Text
UNION
AutoCAD SHX Text
THERMOMETER IN PIPE WELL
AutoCAD SHX Text
PRESSURE GAUGE W/ SHUTOFF COCK
AutoCAD SHX Text
PIPE CAP
AutoCAD SHX Text
FLANGE
AutoCAD SHX Text
FLEXIBLE PIPE CONNECTOR
AutoCAD SHX Text 12"%%C
AutoCAD SHX Text
ROUND DUCT DIMENSION
AutoCAD SHX Text
FLEXIBLE ROUND DUCT
AutoCAD SHX Text
RS
AutoCAD SHX Text
REFRIGERANT SUCTION PIPING
AutoCAD SHX Text
HG
AutoCAD SHX Text
HOT GAS BYPASS PIPING
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
AD
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
WORK TO BE PROVIDED
AutoCAD SHX Text
THIN LINE WEIGHT INDICATES EXISTING
AutoCAD SHX Text
HEAVY LINE WEIGHT INDICATES NEW
AutoCAD SHX Text
EXISTING ITEM TO REMOVE, REFER TO
AutoCAD SHX Text
HEAVY DASHED LINE WEIGHT INDICATES
AutoCAD SHX Text
DEMOLITION NOTES.
AutoCAD SHX Text
ITEM TO REMAIN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
DEMOLITION WORK NOTE
AutoCAD SHX Text
NEW WORK NOTE
AutoCAD SHX Text
LPS
AutoCAD SHX Text
LOW PRESSURE STEAM
AutoCAD SHX Text
LPC
AutoCAD SHX Text
LOW PRESSURE CONDENSATE
AutoCAD SHX Text
OT
AutoCAD SHX Text
OVERRIDE TIMER
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
EM
AutoCAD SHX Text
EMERGENCY SHUTDOWN SWITCH
AutoCAD SHX Text
MARK
AutoCAD SHX Text
FIXTURE
AutoCAD SHX Text
CW
AutoCAD SHX Text
HW
AutoCAD SHX Text
VENT
AutoCAD SHX Text
WASTE
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text P-1
AutoCAD SHX Text P-2
AutoCAD SHX Text P-3
AutoCAD SHX Text P-4
AutoCAD SHX Text
NOTES:
AutoCAD SHX Text
URINAL
AutoCAD SHX Text
LAVATORY (HC)
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text 1"
AutoCAD SHX Text
AutoCAD SHX Text 4"
AutoCAD SHX Text 2"
AutoCAD SHX Text
FLOOR MOUNTED, 1.6 GPF
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
AutoCAD SHX Text 2"
AutoCAD SHX Text 2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1 1/4"
AutoCAD SHX Text 1 1/4"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text 1/2"
AutoCAD SHX Text
WALL MOUNTED, 0.125 GPF.
AutoCAD SHX Text
WALL MOUNTED
AutoCAD SHX Text
1. ALL FIXTURES INDICATED AS HANDICAP ACCESSIBLE (HC) SHALL COMPLY AND BE INSTALLED IN ACCORDANCE WITH THE LATEST ALL FIXTURES INDICATED AS HANDICAP ACCESSIBLE (HC) SHALL COMPLY AND BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE UFAS AND CABO/ANSI A117.1 2. PROVIDE AN EPA WATERSENSE CERTIFIED AND LABELED FIXTURE.PROVIDE AN EPA WATERSENSE CERTIFIED AND LABELED FIXTURE.
AutoCAD SHX Text
FLUSH VALVE WATER CLOSET (HC)
AutoCAD SHX Text
OVERALL DEMOLITION PLAN
WORK NOTES - GENERAL
MD101
DEMOLITION WORK NOTES
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
DEMOLITION FLOOR PLAN - MALE & FEMALE HEADS
KEY PLAN
PARTIAL RISER DIAGRAM - DEMOLITION
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
1. COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE DISRUPTIONS TO ONGOING USE OF ADJACENT SPACES INSIDE BUILDING 3870. 2. ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION ALL CEILING MOUNTED DETECTION, ALARM, AND COMMUNICATION DEVICES TO BE SALVAGED AND REINSTALLED IN OPERATING CONDITION. 3. SEE ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL SEE ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL DEMOLITION WORK REQUIREMENTS. 4. SEE SHEET M-001 FOR LEGEND AND GENERAL NOTES.SEE SHEET M-001 FOR LEGEND AND GENERAL NOTES.
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
MECHANICAL DEMOLITION PLANS
AutoCAD SHX Text
CML
AutoCAD SHX Text
CML
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869576
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
1. REMOVE EXISTING SUPPLY OR RETURN DEVICE. CLEAN AND REMOVE EXISTING SUPPLY OR RETURN DEVICE. CLEAN AND REINSTALL AFTER INSTALLATION. 2. SEE ENLARGED PLAN THIS SHEET SEE ENLARGED PLAN THIS SHEET 3. REMOVE EXISTING EXHAUST GRILLE. CLEAN AND REINSTALL AFTER REMOVE EXISTING EXHAUST GRILLE. CLEAN AND REINSTALL AFTER INSTALLATION. 4. REMOVE EXISTING WATER CLOSET. PREPARE PIPING FOR NEW REMOVE EXISTING WATER CLOSET. PREPARE PIPING FOR NEW FIXTURE. 5. REMOVE EXISTING URINAL, PIPING, AND SUPPORTS. PREPARE PIPING REMOVE EXISTING URINAL, PIPING, AND SUPPORTS. PREPARE PIPING FOR NEW FIXTURE. 6. REMOVE EXISTING LAVATORY AND PIPING. PREPARE PIPING FOR REMOVE EXISTING LAVATORY AND PIPING. PREPARE PIPING FOR NEW FIXTURE. 7. REMOVE EXISTING SHOWER AND PIPING. PREPARE PIPING FOR NEW REMOVE EXISTING SHOWER AND PIPING. PREPARE PIPING FOR NEW FIXTURE. 8. REMOVE EXISTING 3/4" CHS AND CHR PIPING UP TO ISOLATION REMOVE EXISTING 3/4" CHS AND CHR PIPING UP TO ISOLATION VALVE AND CAP. 9. REMOVE EXISTING FCU, PIPING, CONTROLS, COMPLETE. REMOVE EXISTING FCU, PIPING, CONTROLS, COMPLETE. 10. EXISTING 3" VENT UP AND DOWN AND 1 1/2" V TO REMAIN. EXISTING 3" VENT UP AND DOWN AND 1 1/2" V TO REMAIN. 11. REMOVE EXISTING 1" CW BACK TO ISOLATION VALVE. REMOVE EXISTING 1" CW BACK TO ISOLATION VALVE. 12. REMOVE 1/2" CW & HW BACK TO MAIN AND CAP. REMOVE 1/2" CW & HW BACK TO MAIN AND CAP. 13. REMOVE WASTE AND VENT PIPING FOR FIXTURE ON RIGHT TO REMOVE WASTE AND VENT PIPING FOR FIXTURE ON RIGHT TO BELOW FLOOR. 14. CAP WASTE BELOW FLOOR.CAP WASTE BELOW FLOOR.
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text
ROOM C2
AutoCAD SHX Text
ROOM C1
AutoCAD SHX Text
ROOM C15
AutoCAD SHX Text
ROOM C16
AutoCAD SHX Text
ROOM C9
AutoCAD SHX Text
CORRIDOR 2
AutoCAD SHX Text
VESTIBULE 1
AutoCAD SHX Text
VESTIBULE 2
AutoCAD SHX Text
CORRIDOR 1
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NONE
AutoCAD SHX Text
EXST FD
AutoCAD SHX Text
UP TO EF
AutoCAD SHX Text
EXST FCU TO REMAIN
AutoCAD SHX Text 4" V
AutoCAD SHX Text 1 1/2" V
AutoCAD SHX Text 4" W
AutoCAD SHX Text 1 1/2" V
AutoCAD SHX Text 4" W
AutoCAD SHX Text 2" W
AutoCAD SHX Text
FCO
AutoCAD SHX Text
FCO
AutoCAD SHX Text
4" V UP & DN
AutoCAD SHX Text 4" W
AutoCAD SHX Text 2" W
AutoCAD SHX Text 1 1/2" V
AutoCAD SHX Text 1 1/2" V
AutoCAD SHX Text
1/2" CW
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
EXST FD
AutoCAD SHX Text
3/4" CW & HW
AutoCAD SHX Text
1/2" CW & HW
AutoCAD SHX Text
2" W DN & 1 1/2" V UP
AutoCAD SHX Text
4" V UP & DN
AutoCAD SHX Text
1" CW
AutoCAD SHX Text
EXST CHS & CHR PIPING TO REMAIN
1/2" CW & HW
OVERALL NEW WORK PLAN
WORK NOTES - GENERAL
M-101
NEW WORK NOTES
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G
S
YS
TE
M
S C
O M
M
AN
D
DES DRW
SY
M
D
ES
C R
IP
TI
O N
D
AT
E
AP
PR
DRAWFORM REVISION: 25 AUGUST 2020
CHK
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
- M
ID
LA
NT
PW
D
LIT
TL
E
CR
EE
K
JE
B
LC
FS
VI
RG
IN
IA
B
EA
CH
V A
JE
B
LI
TT
LE
C
RE
EK
FO
RT
S
TO
RY
VI
RG
IN
IA
B
EA
CH
, V
A
BU
IL
DI
NG
IN
TE
RI
O R
RE
NO
VA
TI
O
NS
SWSC
KAF
1706934
N/A
ENLARGED NEW WORK FLOOR PLAN
KEY PLAN
PARTIAL RISER DIAGRAM - NEW WORK
AutoCAD SHX Text K-4972-T
AutoCAD SHX Text
STANWELL
AutoCAD SHX Text
C_URINALS
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-2030
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-2030
AutoCAD SHX Text
GREENWICH
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4352
AutoCAD SHX Text
ANGLESEY
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text K-4352
AutoCAD SHX Text
ANGLESEY
AutoCAD SHX Text
TOILET
AutoCAD SHX Text
VITREOUS CHINA
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/8" = 1'-0"
AutoCAD SHX Text
1. COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE COORDINATE ALL CONTRACTOR ACTIVITIES WITH SWSC TO MINIMIZE DISRUPTIONS TO ONGOING USE OF ADJACENT SPACES INSIDE BUILDING 3870. 2. SEE ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW SEE ARCHITECTURAL AND ELECTRICAL DRAWINGS FOR ADDITIONAL NEW WORK REQUIREMENTS. 3. SEE SHEET M-001 FOR LEGEND, GENERAL NOTES, AND FIXTURE SEE SHEET M-001 FOR LEGEND, GENERAL NOTES, AND FIXTURE SCHEDULE.
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/4"=1'-0"
AutoCAD SHX Text 2'
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text
MECHANICAL NEW WORK PLANS
AutoCAD SHX Text
CML
AutoCAD SHX Text
CML
AutoCAD SHX Text
CML
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text 12869577
AutoCAD SHX Text
AutoCAD SHX Text
JCM
AutoCAD SHX Text
1. REINSTALL EXISTING SUPPLY OR RETURN DEVICE. REINSTALL EXISTING SUPPLY OR RETURN DEVICE. 2. SEE ENLARGED PLAN ON THIS SHEET SEE ENLARGED PLAN ON THIS SHEET 3. PROVIDE DUCT EXTENSION AND REINSTALL EXISTING EXHAUST PROVIDE DUCT EXTENSION AND REINSTALL EXISTING EXHAUST GRILLE. 4. EXTEND PIPING FOR NEW HANDICAPPED FIXTURE EXTEND PIPING FOR NEW HANDICAPPED FIXTURE 5. EXTEND PIPING TO NEW SHOWER LOCATIONEXTEND PIPING TO NEW SHOWER LOCATION
AutoCAD SHX Text
SATISFACTORY TO
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
ACTIVITY
AutoCAD SHX Text
DATE
AutoCAD SHX Text
FOR COMMANDER NAVFAC
AutoCAD SHX Text
SEAL
AutoCAD SHX Text
A/E INFO
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text 0'
AutoCAD SHX Text 1/8"=1'-0"
AutoCAD SHX Text 4'
AutoCAD SHX Text 8'
AutoCAD SHX Text 16'
AutoCAD SHX Text
ROOM C2
AutoCAD SHX Text
ROOM C1
AutoCAD SHX Text
ROOM C15
AutoCAD SHX Text
ROOM C16
AutoCAD SHX Text
ROOM C9
AutoCAD SHX Text
CORRIDOR 2
AutoCAD SHX Text
VESTIBULE 1
AutoCAD SHX Text
VESTIBULE 2
AutoCAD SHX Text
CORRIDOR 1
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NIC
AutoCAD SHX Text P-1
AutoCAD SHX Text P-3
AutoCAD SHX Text P-4
AutoCAD SHX Text P-3
AutoCAD SHX Text P-1
AutoCAD SHX Text P-4
AutoCAD SHX Text P-2
AutoCAD SHX Text
SCALE:
AutoCAD SHX Text
NONE
AutoCAD SHX Text 4" V
AutoCAD SHX Text 1 1/2" V
AutoCAD SHX Text 4" W
AutoCAD SHX Text 1 1/2" V
AutoCAD SHX Text 4" W
AutoCAD SHX Text 2" W
AutoCAD SHX Text
FCO
AutoCAD SHX Text 4" W
AutoCAD SHX Text 2" W
AutoCAD SHX Text P-4
AutoCAD SHX Text P-1
AutoCAD SHX Text P-3
AutoCAD SHX Text P-2
AutoCAD SHX Text
EXST FD
AutoCAD SHX Text
UP TO EF
AutoCAD SHX Text
EXST…
This is the start of the file's text. The full file is on GovTribe.