Attachment B Combi Tank Spec 2009 (3).doc

DOC document 49 KB Posted

Attached to
Manufactured Combi Fish Tanks
Solicitation number
RFQ - 18P - 09062900000000000971
Issued by
Kennebec County, Maine

About this file

This is a specification document for Fiber-Reinforced Plastic Combi Fish Culture Tanks issued by the State of Maine. The specification outlines requirements for the supply and delivery of complete Combi Fish Culture Tank systems, which include a main tank, first feeder tray, egg tray, plumbing kit, and legs. The document establishes comprehensive submittal requirements, including detailed product data, shop drawings, assembly and installation instructions, and specifications for all components such as water inlet and outlet locations, tank dimensions and capacity, material compositions, pipe connection sizes and types, floor and wall slopes, interior and exterior colors, finishes with UV absorbers, screen samples, and accessory items. The State of Maine is fully responsible for shipping all fibreglass items to the project location, with the manufacturer required to adequately crate and protect materials from damage during transit. Damaged units may be rejected and returned to the manufacturer at the vendor's expense. All equipment and accessories are to carry warranties for materials and workmanship valid for a minimum of one year from final acceptance by the State of Maine.

The specification establishes strict material requirements prohibiting any materials containing cadmium, brass, bronze, copper, zinc, or their alloys that could contact fish rearing water due to toxicity concerns. The minimum fibreglass thickness is specified at 3/16 inches, with all factory perforations sealed with resin and gel coat. The document includes detailed laminate defect standards and permissible limits across multiple categories including blisters, chips, cracks, crazing, dry spots, and other manufacturing defects. Fish exclusion screens for the main tank must be manufactured from semi-rigid PVC with opening slots measuring 1/16 by 1/2 or 3/4 inches. Tank bottom center drain fittings are to be constructed of PVC as an integral part of the main tank, and stainless steel or aluminum fasteners are required for assembling component pieces to prevent corrosion.

View the file

Other files

File Type Posted
Conditions and Instructions to Bidders.doc DOC document
Revised Spec Summary Combi Tank.doc DOC document
Three_Inch_Center_Stand_Pipe__Tank_Bottom_Fittings.BMP.crdownload CRDOWNLOAD file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION 00 00 00

FIBER-REINFORCED PLASTIC COMBI TANKS

PART 1 - GENERAL

1.01 SUMMARY

A. Supply Combi Fish Culture Tanks in accordance with the requirements of SECTION 00 70 00 – CONDITIONS OF THE CONTRACT. The Combi Fish Culture Tank(s) includes the main tank, first feeder tray, egg tray, plumbing kit and legs.

1.02 REFERENCES

A. Commercial Standards

1. ASTM

American Society for Testing and Materials

2. ANSI/ASME

Performance Test Code

3. AWWA

American Water Works Association

1.03 SUBMITTALS

A. Product Data and Shop Drawings: Submit complete drawings in accordance with bid instructions for the Fish Culture Tank and equipment as a complete system.

B. SUBMITTAL PROCEDURES. The following are to be included in the submittal:

1. Product data and shop drawings. Drawings are to show locations and connections of water inlet and outlet.

2. Equipment name and applicable specification number

3. Product data to include:

a. Main Tank Construction materials

b. First (1st) feed tank

c. Egg tray construction

d. Dimensions and capacity

e. Components including resin and reinforcement

f. Exact pipe connection sizes, types and locations

g. Floor and wall slopes

h. Tank interior and exterior color

i. Finishes including UV absorbers, pigments and gelcoats

j. Weights and thicknesses of materials and coatings such as gel coat

k. Specifications for accessory items l.

Screen samples for each component (egg tray and all fish exclusion screens)

4. Assembly and Installation Drawings: Complete assembly and installation drawings and instructions including piping, equipment assemblies, required clearances, method of field assembly, location and size of each field assembly, mounting and anchoring.

1.04 DELIVERY, STORAGE, AND HANDLING

A. Packing, Shipping, Handling and Unloading: Manufacturer shall provide shipping of all items specified to the project location. The State of Maine shall make the Manufacturer fully responsible to adequately crate and protect all fibreglass items from damage during shipping. Damaged units may be rejected and returned to the manufacturer for replacement or repair at vendor’s expense.

B. Storage and Protection: Stored units shall be kept fully crated and protected from damage at all times prior to installation.

1.05 WARRANTY

Warranties for materials and workmanship for all equipment and accessories as specified in this section are to be valid for a period of not less than one (1) year, starting from final acceptance by the State of Maine.

PART 2 - PRODUCTS

2.01 ACCEPTABLE MANUFACTURERS

As per specifications listed below or approved equal.

2.02 MATERIALS

A. The contractor shall not install any material containing cadmium, brass, bronze, copper, zinc, or their alloys, which could come in contact with fish rearing water. These heavy metal materials have been shown to be toxic to fish.

1. The minimum fibreglass thickness shall be 3/16 inches.

2. All factory perforations must be sealed with resin and gel coat.

3. A visual inspection of the laminate shall be made by the manufacturer. Laminate defects and the permissible limits shall be in accordance with the following table:

Defect
Process Surface
None Process Surface
Blisters
None
Max ¼ inch diameter, 0.0625 inch high
Burned Areas
None
None
Chips
None
Max ¼ inch with max thickness 20% of wall
Cracks
None
None
Crazing
None
Slight
Dry Spots
None
Max 2 sq. in./sq. ft.
Entrapped Air
None at surface
0.125 inch diameter max; no more than 3% laminate, 0.0625 inch diameter of area, max 10/sq. in.
Exposed Glass
None
None
Exposed Cut Edges
None
None
Foreign Mater
None
None if it effects the properties of the laminate
Pits
Max 0.125 inch by 0.03125 inch deep, max 10/sq. ft.
Max 0.125 inch diameter by 0.0625 inch deep
Scratches
None (Coated)
None (Coated)
Surface Porosity
None
None
Wrinkles
Max deviation 20% of wall thickness
Max deviation 20% of wall thickness
Sharp Discontinuity
None
None

B. Fish Exclusion Screens for bottom of 3 Inch Outer Standpipe of Main Tank must be manufactured using semi-rigid PVC or equivalent. Opening slots shall have openings of _1/16_ by __1/2_or 3/4__ inches.

C. Tank bottom center drain fitting will be constructed of PVC & made an integral part of the Main Tank bottom.

D. A removable 2” PVC Inner water level control standpipe and its associated fitting(s) will be provided by the State of Maine. Refer to “Three Inch Outer Stand Pipe & Tank Bottom Fittings” drawing for Center Stand Pipe requirements.

E. Use stainless steel or aluminium fasteners where required to assemble component pieces unless noted otherwise.