Attachment A3 - Standard Plans (1).pdf

PDF 540 KB Posted

Attached to
As-Needed Shoulder Gravel Maintenance-Baraga & Houghton Co. s
Solicitation number
RFP 591 210000001610 2
Issued by
Arenac County, Michigan

About this file

Summary of Attachment A3 - Standard Plans

This document is a technical standard plan prepared by the Michigan Department of Transportation (MDOT) Bureau of Development for temporary traffic control devices and sign installations. The standard plans establish specifications for temporary warning signs, barricades, and related support structures used in road work and traffic management applications. The plans detail three types of sign construction (Type I aluminum extrusion, Type II plywood, and Type III aluminum sheet) with varying size categories ranging from signs 36 inches by 36 inches to those 144 inches wide. Installation requirements specify support post configurations using wood posts (4" x 6" or 6" x 8" nominal), square tubular steel, U-channel steel, or aluminum extrusions, with detailed specifications for post spacing, embedment depth (minimum 42 inches), and breakaway hole details. The document includes comprehensive design drawings and installation guidance for temporary sign support systems and Type III barricades with reflectorized sheeting options in orange and white configurations.

The technical specifications address material requirements including galvanized hardware, bolt specifications (5/16" and 3/8" diameter galvanized bolts per SAE J429 Grade 5), and structural details for sign panel connections and reinforcement. General notes emphasize compliance with NCHRP 350 crash worthiness standards, maximum post spacing within a 7-foot path of two posts, and requirements that all labor, materials, equipment, and temporary supports for installation, maintenance, relocation, and removal are included in the cost of the temporary sign. The standard plan accommodates multiple installation configurations for rural and urban environments with specified minimum clearances (4 feet to 7 feet minimum depending on location type) and provides detailed specifications for temporary sign stands, warning light attachments, and ballasting requirements using sandbags.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

(ft )

SIGN AREA

9_<

9 _ 20<

N/A1 - 3 lb/ft

2 - 3 lb/ft 1 - 4" X 6"

2 - 4" X 6"

2 - 6" X 8"N/A

N/A

SIGNS 4 FEET AND GREATER IN WIDTH REQUIRE 2 POSTS.

36" X 36"

> X

X

X X

1 - 2" 12 or 14 GA

2 - 2" 12 or 14 GA

X

X> 144" WIDE

ROUNDING OF CORNERS IS NOT REQUIRED FOR TYPE I OR II SIGNS.

VERTICAL JOINTS ARE NOT PERMITTED.

HORIZONTIAL JOINTS THROUGH SIGN LEGEND OR SYMBOLS ARE NOT PERMITTED.

A MAXIMUM OF 2 POSTS WITHIN A 7' PATH IS PERMITTED.

<> N/A 3 - 6" X 8"

SIGNS GREATER THAN 8 FEET IN WIDTH REQUIRE 2 OR 3 WOOD

POSTS DEPENDING ON AREA OF SIGN.

36" X 36" _ 96" TO WIDE

POST TYPE

2 WOODSQUARE TUBULAR STEELU-CHANNEL STEEL

20 _ 30

N/A

N/A

POST SIZE REQUIREMENTS TABLE

SIGN MATERIAL SELECTION TABLE

SIGN SIZE TYPE I TYPE II TYPE III

SIGN MATERIAL TYPE

TYPE I ALUMINUM EXTRUSION

30 _ 60

60 _ 84 N/A

96" WIDE TO 144" WIDE

SUPPORTS FOR TEMP SIGNS

GROUND DRIVEN SIGN

WZD-100-AAUG

CON/ECH

1 11 11/2/2017

DEPARTMENT DIRECTOR MICHIGAN DEPARTMENT OF TRANSPORTATION

OF

SHEET

PLAN DATEF.H.W.A. APPROVALCHECKED BY:

DRAWN BY:

Michigan Department of Transportation

APPROVED BY:

APPROVED BY:

Kirk T. Steudle

BY

PREPARED

DESIGN DIVISION

DIRECTOR, BUREAU OF FIELD SERVICES

BUREAU OF DEVELOPMENT STANDARD PLAN FOR

DIRECTOR, BUREAU OF DEVELOPMENT

DISTANCE BETWEEN OUTSIDE POSTS.

SPREAD POSTS SO AS TO HAVE A 8' MIN. TO 9' MAX.

FOR ALL 11' AND 12' LONG SIGNS ON 3 WOOD SUPPORTS,

SIGN

L

2 POST SIGN SUPPORT SPACING

1/6L 1/6L2/3L

SIGN

L

1/6L 1/6L

3 POST SIGN SUPPORT SPACING

1/3L 1/3L

2 11

11/2/2017 WZD-100-A

NOT TO SCALE

MICHIGAN DEPARTMENT OF TRANSPORTATION

PLAN DATEF.H.W.A. APPROVAL

SHEET

OF

NOTE: THE ORIGINAL SIGNED COPY IS KEPT ON FILE AT THE MICHIGAN DEPARTMENT OF TRANSPORTATION.

BUREAU OF DEVELOPMENT STANDARD PLAN

AHEAD

CLOSED

ROAD

ROAD

WORK

AHEAD

DETOUR

AHEAD

AHEAD

CLOSED

RIGHT LANE

M.P.H.

BOTTOM HEIGHT AND OFFSET

6'-12' 6'-12'

6'

RURAL

URBAN

5' MIN.

2'

7' MIN.

2'

7'MIN.

4'MIN.

URBAN

4" MAX.4" MAX.

WZD-100-A

3 11

PAVED SHOULDER

SPEED PLATE

RURAL WITH ADVISORY

WALKWAY WALKWAY

WALKWAYS ARE PRESENT)

(CURBED AREAS OR WHERE

WALKWAYS ARE PRESENT)

(CURBED AREAS OR WHERE

11/2/2017

SHEET

OF

C

X X

P O

S T

L E

N G

H

V A

R I

E S

3 3/4" MAX.

D I

O

L

M

N

N

X

3" MIN.

X X

TRAFFIC FLOW

WEIGHT = 3 lbs/ft

1" MIN.

1†" MAX.

L

SECT. MOD. X.-X. = 0.31 CUBIC INCHES MIN.

WZD-100-A 4 11

U - CHANNEL STEEL POST

MOUNT SIGN ON OPEN FACE OF

(NO SPLICE)

3 lb. U - CHANNEL STEEL POST

SHEET

OF

A A

N

N

U P

P

R

P

S T

N

P

UPPER SPLICE LOWER SPLICE

A A

N

P

TRAFFIC FLOW

U P

P

S T

D R I

V

U B

D R I

V

U B

5 11

UPPER U - CHANNEL STEEL POST

MOUNT SIGN ON OPEN FACE OF

2 REQUIRED

5/16" BOLTS

2 REQUIRED

5/16" BOLTS

2 REQUIRED

5/16" BOLTS

2 REQUIRED

5/16" BOLTS

(WITH SPLICE)

3 lb. U - CHANNEL STEEL POST

SHEET

OF

7/16"

NOTES:

UPPER POSTDRIVEN POST

TRAFFIC FLOW

5/16" BOLT

SPACER DETAIL

3/4" O.D.

3/8" I.D.

SPACER THICKNESS

SECTION A-A

1. THE SPACER THICKNESS SHALL BE 1/16" LESS THAN THE GAP BETWEEN THE POST

WHEN POSITIONED IN THE UNBOLTED CONFIGURATION.

2. THE EXTERIOR BOLT (CLOSEST TO LAP), SPACER, WASHER, AND NUT SHALL BE

INSTALLED IN A PREPUNCHED HOLE 1" to 2" FROM THE END OF THE LAP.

3. THE INTERIOR BOLT (FARTHEST FROM LAP), SPACER, WASHER, AND NUT SHALL BE

INSTALLED IN THE NEXT PREPUNCHED HOLE.

4. THE DRIVEN POST SHALL ALWAYS BE MOUNTED IN FRONT OF THE UPPER POST

WITH RESPECT TO THE ADJACENT ONCOMING TRAFFIC, REGARDLESS OF THE

DIRECTION THE SIGN IS FACING.

5. THE SPLICE LAP SHALL BE FASTENED BY FOUR-5/16" DIA. GALVANIZED A449 BOLTS

(SAE J429 GRADE 5) OR GALVANIZED A325 BOLTS.

6 11

(WITH SPLICE)

3 lb. U - CHANNEL STEEL POST

O.D. 3/4" MIN., I.D. 3/8" MAX.

REQUIRED FOR ALL BOLTS

7/16" SPACER

SHEET

OF

3# POST

VARIES VARIES VARIES

A

A

SECTION A-A

FRONT

1. MATERIAL: 12 GAUGE CARBON STEEL.

3. FINISH-AFTER STAMPING AND PUNCHING,

GALVANIZE ACCORDING TO CURRENT

3 1/2"

1 3/4" 1 3/4"

7/16" DRILL

EQUAL TO POST THROAT

OPENING DIMENSION

2. TOLERANCE ON ALL DIMENSIONS 0.0625"

SPECIFICATIONS FOR ZINC (HOT

GALVANIZE) COATINGS ON PRODUCTS

FABRICATED FROM PLATES OR STRIPS

NOTES: (FOR STEEL SIGN REINF' PLATE)

0.19" R

PLYWOOD (TYPE II) OR ALUMINUM SHEET (III) SIGN

STEEL SIGN REINFORCING PLATE

SIGN TO 3 lb. POST CONNECTION

3 lb. U - CHANNEL STEEL POST SIGN CONNECTION

REQUIRED FOR TYPE III SIGNS ONLY

5/16" DIAMETER GALVANIZED BOLT

AND NUT

FLAT WASHER

WZD-100-A 7 11

(TYP. ALUMINUM SHEET [TYPE III] SIGN ONLY)

REINFORCING PLATE

SELF-ALIGNING STEEL

SHEET

OF

(4" X 6" (NOMINAL) POST) 1 1/2" DIA. 2 HOLES

(6" X 8" (NOMINAL) POST) 3 1/2" DIA. 2 HOLES

N

8" DIA. AUGERED HOLE FOR 4" X 6" POST

10" DIA. AUGERED HOLE FOR 6" X 8" POST

5•" OR 7•" (ACTUAL)

SAW CUT DETAIL

5 1/2 " OR 7 1/2" ACTUAL

TRAFFIC FLOW

WOOD POST DETAILS

(MULTIPLE POST INSTALLATIONS)

TRAFFIC FLOW

SIGN PANEL

CONSTRUCTION.

THE STANDARD SPECIFICATIONS FOR

SECTION 912 OF THE CURRENT EDITION OF

WOOD POST SHALL BE IN CONFORMANCE TO

WZD-100-A 8 11

LAYERS, TAMPING EACH LAYER.

EXISTING MATERIAL IN FIVE EQUAL

AUGERED HOLE. IF AUGERED, BACKFILL WITH

THE POST MAY BE DRIVEN OR PLACED IN AN

S I

N G

S E

M B

L I

E S

W

U

T

E X

C E

P T

I

N

(FOR 6" X 8" NOMINAL POST) 1 1/2"

(FOR 4" X 6" NOMINAL POST) 1"

CENTERED ON POSTS.

HOLES ARE TO BE

DRILLED BREAKAWAY

DIRECT EMBEDMENT DETAILS

WOOD POST BREAKAWAY HOLES/

SHEET

OF

POST ASSEMBLIES

EXCLUDE SAW CUT ON SINGLE

SAME AS BOLT ABOVE

TYPE II AND TYPE III SIGNS

END VIEW REAR VIEW

C OF POST

1 1/2"

(TYP.)

P A

N E

L

W I

D T

H

TOP VIEW

LENGTH ALL EXTRUSIONS.

L

1/2"

O

T Y

P

12"

T Y

P

4" X 6" (NOMINAL) OR 6" X 8" (NOMINAL) WOOD POST

ON APPROX. 24" CENTERS FULL

TYPE I SIGN

WOOD POST CONNECTIONS

TYPE I SIGN - ERECTION DETAILS

L

1/6 SIGN LENGTH

(TYP.)

3/8" DIA. GALVANIZED BOLTS

WZD-100-A

(TYP.)

1 1/2"

(TYP.)

STIFFENER ANGLE

SPACING

HOLE

TYPICAL

ALIGNMENT OF PANELS.

USED TO FACILITATE

E

X

N

X

N

TYP.

2"

BOLT HOLES MAY BE

1/2" X 3/4" ELONGATED

M A

X

M A

X

CORNER RADIUS (TYP.)

0.040" EXTERIOR

(ALUM.) x SIGN HEIGHT

L 2" X 2" X 1/4"

STIFFENER ANGLE-

FOR CONSTRUCTION

SPECIFICATIONS

PER MDOT STANDARD

ALUMINUM EXTRUSION

SIGNS

ALUMINUM SHEET (TYPE III)

PLYWOOD (TYPE II) OR

(TYPE I) SIGN

ALUMINUM EXTRUSION

SAW CUT

FLAT WASHER

GALVANIZED

HEX. HD. BOLT

3/8" DIA. GALVANIZED

NYLON INSERT LOCKNUT

GALVANIZED

FLAT WASHER

GALVANIZED

NYLON INSERT LOCKNUT (TYP.).

WASHERS & GALVANIZED

2 GALVANIZED FLAT

3/8" DIA. GALVANIZED BOLT,

BE INSTALLED ON EITHER SIDE OF EACH POST.

ALUMINUM L 4" X 3" X 3/8" ANGLES MAY

GALVANIZED BOLTS.

C OF HOLES FOR 3/8" DIA.

ALIGNMENT OF ALUMINUM ANGLES.

HOLES MAY BE USED TO FACILITATE

1/2" X 3/4" ELONGATED BOLT

EACH PANEL.

BOLT STIFFENER ANGLE TO

NYLON INSERT LOCKNUTS.

& GALVANIZED

GALVANIZED FLAT WASHERS

RECTANGULAR FLAT BOLTS,

GALVANIZED 3/8" DIA.

9 11

SHEET

OF

N G

V

R I

E S

ANCHOR SLEEVE

GRADE

SQUARE TUBULAR STEEL POST

M I

N

N

D

L

TUBE SIZE = 2•" X 2•"

WALL THICKNESS = 12 GA

W

P O

S I

F

U

D E

S

SIGN POST

TUBE SIZE = 2" x 2"

WALL THICKNESS =12 OR 14 GA

X

INSERT CONNECTION HARDWARE

(PER MANUFACTURER'S

SPECIFICATIONS)

WZD-100-A

SIGN CONNECTION LOCATIONS.

ANCHOR/POST CONNECTION AND

HOLES OPTIONAL EXCEPT FOR

10 11

SHEET

OF

1. A MAXIMUM OF TWO POSTS WITHIN A 7 FOOT PATH IS PERMITTED.

GENERAL NOTES:

3. ALL POSTS SHALL BE EMBEDDED A MINIMUM OF 42".

2. ALL SIGN POSTS SHALL COMPLY WITH NCHRP 350.

13. POSTS SHALL NOT EXTEND MORE THAN 4" ABOVE TOP OF SIGN.

10. REMOVE SIGN POSTS AND/OR POST STUBS IN THEIR ENTIRETY WHEN NO LONGER

REQUIRED.

11. ALL LABOR, MATERIALS, AND EQUIPMENT, INCLUDING TEMPORARY SUPPORTS

12. SAW CUTS IN WOOD POSTS ARE TO BE PARALLEL TO THE BOTTOM OF THE SIGN.

4. BRACING OF POST IS NOT PERMITTED.

5. SIGN SHALL BE LEVEL, AND UPRIGHT FOR THE DURATION OF INSTALLATION.

6. ERECT POSTS SO THE SIGN FACE AND SUPPORTS DO NOT VARY FROM PLUMB

BY MORE THAN 3/16" IN 3'. PROVIDE A CENTER-TO-CENTER DISTANCE

BETWEEN POSTS WITHIN 2 PERCENT OF PLAN DISTANCE.

7. NO MORE THAN ONE SPLICE PER POST, AS SHOWN, WILL BE PERMITTED.

8. POST TYPES SHALL NOT BE MIXED WITHIN A SIGN SUPPORT INSTALLATION.

WZD-100-A

THROUGH SIGN LEGEND OR SYMBOLS ARE PERMITTED IN SIGN

9. NO VERTICAL JOINTS ARE PERMITTED IN SIGN. NO HORIZONTIAL JOINTS

11 11 11/2/2017

REQUIRED TO INSTALL, MAINTAIN, RELOCATE, AND/OR REMOVE THE TEMPORARY

SIGN, INCLUDING SUPPORTS, ARE CONSIDERED TO BE INCLUDED IN THE COST

OF THE TEMPORARY SIGN.

14. TEMPORARY WOOD SUPPORTS DO NOT REQUIRE PRESERVATIVE TREATMENT.

SHEET

OF

ECH

MWB

ENGINEER OF DEVELOPMENT

Traffic Control Devices

Temporary

WZD-125-E 1 3

6" MIN.

12" MAX.1

8'-0" o

(12 REQUIRED)

1" MIN. O.D. STEEL FLAT LOCK WASHER

…" - 16 STEEL HEX NUT

…" - 16 STEEL HEX BOLT

6" MIN.

12" MAX.1

8'-0" o

(12 REQUIRED)

1" MIN. O.D. STEEL FLAT LOCK WASHER

…" - 16 STEEL HEX NUT

…" - 16 STEEL HEX BOLT

FRONT ELEVATION SIDE VIEW

FRONT ELEVATION SIDE VIEW

PERFORATED SQUARE STEEL TUBE OPTION

BI-DIRECTIONAL RIGHT DIRECTIONALLEFT DIRECTIONAL

T Y

P

T Y

P

ANGLE IRON OPTION

(12 GAGE)

SQUARE STEEL TUBE

1ƒ" PERFORATED

(10 GAGE)

1•" x 1•" ANGLE

C

C C

C C

C C

C ƒ" HOLLOW EXTRUDED RIGID POLYOLEFIN ƒ" HIGH DENSITY POLYETHYLENE OR ƒ" ACX PLYWOOD OR

BARRICADE RAIL MAY BE

ƒ" HOLLOW EXTRUDED RIGID POLYOLEFIN ƒ" HIGH DENSITY POLYETHYLENE OR ƒ" ACX PLYWOOD OR

BARRICADE RAIL MAY BE

CLOSURES

(TYPICAL)

ORANGE

REFLECTORIZED

(TYPICAL)

SILVER (WHITE)

REFLECTORIZED

(TYPICAL)

SILVER (WHITE)

REFLECTORIZED

(TYPICAL)

ORANGE

REFLECTORIZED

BARRICADE RAIL SHEETING OPTIONS

TYPE III BARRICADES

(12 GAGE)

2" SQUARE STEEL TUBE

4'-0" - 6'-0"

4'-0" - 6'-0"

(12 GAGE)

2" SQUARE STEEL TUBE8

O R

2" x 2" x ‰" ANGLE

2" x 2" x ‚" ANGLE OR OF BASE

WELD TO CENTER

OF BASE

WELD TO CENTER

" 1•" x 1•" ANGLE (10 GAGE)

2" x 2" x ‰" ANGLE OR

2" x 2" x ‚" ANGLE OR http://safety.fhwa.dot.gov/roadway_dept/road_hardware/wzd.htm

Other Type III Barricades meeting current NCHRP crash worthy criteria can be found on the FHWA Safety website at

(SPECIAL DETAIL) 1/18/11

THROUGH UPRIGHT AND RAIL

WITH VANDAL RESISTANT HARDWARE

LIGHTWEIGHT WARNING LIGHT ATTACHED

THROUGH UPRIGHT

WITH VANDAL RESISTANT HARDWARE

LIGHTWEIGHT WARNING LIGHT ATTACHED

DEPARTMENT DIRECTOR MICHIGAN DEPARTMENT OF TRANSPORTATION

OF

SHEET

PLAN DATEF.H.W.A. APPROVALCHECKED BY:

DRAWN BY:

Michigan Department of Transportation

APPROVED BY:

APPROVED BY:

Kirk T. Steudle

BY

PREPARED

DESIGN DIVISION

DIRECTOR, BUREAU OF FIELD SERVICES

BUREAU OF DEVELOPMENT STANDARD PLAN FOR

DIRECTOR, BUREAU OF DEVELOPMENT

6'-0"

(4 REQUIRED)

STEEL HEX BOLT WITH Œ" NUT

…" x 2•" - 16 ZINC COATED

1" ON CENTER, ALL FOUR SIDES

PSST STEEL TUBING WITH …" HOLES

12 OR 14 GAGE GALVANIZED UPRIGHT

1ƒ" x 1ƒ" x 9'-0"

REFLECTIVE SHEETING

3'-4"

PLACED 6" FROM BOTTOM OF UPRIGHT

1" ON CENTER, ALL FOUR SIDES

PSST STEEL TUBING WITH …" HOLES

12 GAGE GALVANIZED SLEEVE

2" x 2" x 3'-0"

ON THREE SIDES

IRON BY ‚" x 2" WELDS

ATTACH STUB TO ANGLE

FOR INSERTING UPRIGHT

6" HIGH (12 GAGE)

2" SQUARE STEEL TUBE

FRONT ELEVATIONSIDE VIEW

TEMPORARY SIGN SUPPORT

(WARNING LIGHT PLACED ON SIDE CLOSEST TO TRAFFIC)

T

Y P

Z-BRACKET DETAIL

1‚"

1ƒ"

14 GAGE STEEL

3"

1•"1•"

Œ" DIA. HOLE

ƒ

PLACED IN OUTERMOST SLOT

AND BATTERY MUST BE

OF SIGN A MINIMUM OF 1"

MUST PROTRUDE FROM EDGE

WARNING LIGHT HOUSING

FROM THE EDGE LINE OF THE PANEL

WITH BOLT PROTECTION CUP. LOCATE BOLT 2" IN

Z-BRACKET ATTACHED WITH •" x 4" HALF MOON BOLT

WITH 6 VOLT SINGLE LANTERN TYPE BATTERY HELD BY

LIGHTWEIGHT (3.3 LBS. MAX.) WARNING LIGHT TYPE A

2" x 2" x ‰" ANGLE *

2" x 2" x ‚" ANGLE OR

* SIGN STAND IS BALLASTED WITH FOUR OR MORE 35 LB SANDBAGS. A MINIMUM OF ONE ON EACH END.

UPRIGHTS SHALL NOT EXTEND ABOVE THE SIGN PANEL.

(OPTIONAL)

INSERTED IN THE HOLE OF PANEL

NYLON WASHER (SEE DETAIL BELOW)

TIGHTENED TO CUP WASHER

AND 1•" FLAT WASHER ˆ" THICK

STEEL HEX BOLT WITH Œ" NUT

…" x 3" - 16 ZINC COATED

1‚" DIA. HOLE IN PANEL FOR

OPTIONAL NYLON WASHER

…" DIA. HOLE

„"1„"

(MEDIUM DENSITY OVERLAY PLYWOOD)

48" x 48" x •" PANEL http://safety.fhwa.dot.gov/roadway_dept/road_hardware/wzd.htm

Other temporary sign supports meeting current NCHRP crash worthy criteria can be found on the FHWA Safety website at

R U

R A

U R

B A

N

1/18/11SPECIAL DETAIL WZD-125-E 2 3

SHEET

OF

WZD-125-E

NOTES:

PLASTIC DRUM

A P

P R

O X

REMAINDER OF DRUM

2" MAX.

NON REFLECTORIZED ORANGE

REFLECTORIZED WHITE

REFLECTORIZED ORANGE

X

S

T E

18" MIN.

SYMBOLS TO BE USED ON PLANS

EXISTING TYPE III BARRICADE

PROPOSED TYPE III BARRICADE

PLASTIC DRUM

TRAFFIC CONTROL DEVICE.

SO THEY WILL NOT COVER OR OBSTRUCT ANY REFLECTIVE PORTION OF THE

ACHIEVE STABILITY OF THE BARRICADE. THE SANDBAGS SHALL BE PLACED

SANDBAGS SHALL BE USED WHEN SUPPLEMENTAL WEIGHTS ARE REQUIRED TO

SPECIFICATIONS FOR CONSTRUCTION.

SENSITIVE REFLECTIVE SHEETING ACCORDING TO THE CURRENT STANDARD

SIGNS, BARRICADES, AND PLASTIC DRUMS SHALL BE FACED WITH PRESSURE-

SHALL BE ORANGE IN COLOR AND EQUAL IN WIDTH.

THE HORIZONTAL REFLECTORIZED ORANGE AND WHITE STRIPES

STRIPE BEING ORANGE. NON REFLECTORIZED SPACES BETWEEN

ALTERNATING IN COLOR WITH THE TOPMOST REFLECTORIZED

STRIPES (2 ORANGE AND 2 WHITE) OF 6" UNIFORM WIDTH,

DRUMS SHALL HAVE AT LEAST 4 HORIZONTAL REFLECTORIZED

NOTE:

3 3 1/18/11

OF PLASTIC DRUMS FOR PLACEMENT OF TEMORARY CONCRETE BARRIER.

DIVIDED ROADWAY, AND R-126-SERIES FOR TYPICAL LOCATION AND SPACING

SEE ROAD STANDARD PLANS R-113-SERIES FOR TEMPORARY CROSSOVERS FOR

CONTRACT ON TYPE III BARRICADES.

SPECIFICATIONS FOR CONSTRUCTION AND ALL OTHER PROVISIONS IN THE

WARNING LIGHTS SHALL BE PLACED ACCORDING TO THE CURRENT STANDARD

HORIZONTAL BASE OF THE TYPE III BARICADE.

2" PERFORATED SQUARE STEEL TUBES MAY BE USED TO FABRICATE THE

(SPECIAL DETAIL)

SHEET

OF

wzd-125-e
wzd-125-e1
wzd-125-e2