Attachment A3 Equipment and System List.docx

DOCX document 23 KB Posted

Attached to
Facility Maintenance Services for Warrenton VA - Amendment 5 Federal contract opportunity
Solicitation number
693KA9-21-R-00016
Issued by
Department of Transportation Federal Aviation Administration Headquarters

View the file

Other files for this federal contract opportunity

Other files attached to Facility Maintenance Services for Warrenton VA - Amendment 5, newest first.
File Type Posted
Attachment S-5 Planned Building Configuration and Exterior Photos.docx DOCX document
SIR 693KA9-21-R-00016-Rev 1.docx DOCX document
Government Respnses to QA Submissions.pdf PDF
693KA9-21-R-00016 SF-33 Cover Pg.pdf PDF
Attachment S-3 Past Performance Questionnaire Rev1.doc DOC document
Attachment A-5 SCA Wage Determination Register 15-4281 Rev No 19.pdf PDF
Attachment S-4 BusinessDeclarationForm.pdf PDF
Attachment S-3 Past Performance Questionnaire 042820.doc DOC document
SIR - 693KA9-21-R-00016.docx DOCX document
Attachment A4 Janitorial Services.doc DOC document
Attachment A2 As-Built Drawings.pdf PDF
Attachment A1 Building Description and Structures.docx DOCX document
Attachment S-2 CLIENT AUTHORIZATION LETTER Warrenton.docx DOCX document
Attachment S-1_Question and Comments Form_.doc DOC document
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT A3

EQUIPMENT AND SYSTEM LIST

Note: Existing equipment maybe upgraded during renovations. An updated equipment and systems list will be provided upon completion.

Mechanical

· Four 30- ton (each) McQuay Package roof-top AC Units with Gas Heat. Existing 30 ton rooftop units have 15 HP supply and 7-1/2 HP return air fans. The 30 ton units have 2 small compressors.

· 69 VAV Boxes (exterior zone boxes have electric heat); Distech Tridum direct digital control system; web-based controls. System does not monitor mini-split system.

· 7 mini-split systems and electric wall heaters; Mitsubishi Mr. Slims.

· Tridium web-based control system with Distech sensors, controls the roof-top units and VAV boxes.

Electrical

· Two 800 amp, 480 volt services from a 750 kVA utility transformer

· Electrical distribution is dual voltage 120/208 and 277/480

· Gas-fired Katolight Emergency Generator

Plumbing

· Toilets are tank type

· Electric domestic water heater

· A 6” combined water/sprinkler system serves the building

· Grinder pump (exterior of bldg)

· Building sprinklered throughout. Standpipes do not exist and are not required due to building height.

Other

· One passenger hydraulic elevator

· Compressed air system for tools

· Mircom fire alarm system

· Six skylights located off main entrance lobby. Acrylic lenses.

Fire

· Fire Suppression fully sprinkled with a wet system

· Fire extinguishers located through-out the building

Gas

· Hot water heater; gas fired

· Natural gas pipping

File details come from the government source that posted it. Updated .