Attachment_A_-_Melbourne_Courthouse_MCH_Drawings_and_Specifications.pdf

PDF 2 MB Posted

Attached to
Melbourne Courthouse & Historic Titusville Courthouse Lightning Protection System
Solicitation number
B-2-26-09
Issued by
Brevard County, Florida

About this file

This file consists of construction drawings and specifications prepared by CMTA Associates, Inc. for the Melbourne Courthouse Lightning Protection System project located at 51 Nieman Avenue #100, Melbourne, Florida 32901, developed for Brevard County. The project documents include a cover sheet, general notes and electrical legend, electrical specifications, lightning protection roof plan, and electrical details, all digitally signed and sealed by Professional Engineer Kyriakos Liatsos on September 30, 2025. The drawings are designated as Project Number 2024-0202.00 and comprise five sheets (C001, E001, E002, E101, and E401) at various scales. These construction documents serve as the technical basis for the sealed bid procurement (Bid #B-2-26-09) for lightning protection system installation, with mandatory pre-bid walkthroughs scheduled for January 8, 2026, at 10:00 AM at the Melbourne Courthouse and sealed bids due January 27, 2026, at 10:00 AM at the Brevard County Central Services/Purchasing office.

The project requires contractors certified by Underwriters Laboratories (UL) or the Lightning Protection Institute (LPI) to furnish all labor, materials, and equipment for comprehensive lightning protection system installation. Bidders must possess multiple licenses including Certified Building Contractor (BC), Certified General Contractor (GC), and Certified Electrical Contractor (EC), with electrical work performed by a licensed electrical contractor. The specifications permit two installation options: a standard NFPA 780 Class I lightning protection system or an Early Streamer Emission (ESE) system, with compliance required to Florida Building Code 2023, NEC 2020, NFPA 780, and UL96A standards. Upon completion, contractors must provide UL Master Label certification. The contract timeline includes a 30-calendar-day period for Substantial Completion and an additional 30 days for Final Completion from the Notice to Proceed. Contractors must maintain $1,000,000 in General Liability and Auto Liability Insurance and provide a 5% bid bond. Lump sum pricing must be submitted separately for each courthouse location, with the Melbourne Courthouse and Historic Titusville Courthouse both requiring installations.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Drawing Number:

File Name:

Checked By:

Project Number:

Date:

Drawn By:

Sheet Title:

Project Title:

Client:

Seal:

Scale:

Description

M

EL

BO

U

R N

E C

O U

R

TH

O U

SE

LI

G H

TN

IN

G P

R O

TE

C

TI

O

N

N

IE

M

AN

A

VE

0, M

EL

BO

U

R N

E, F

L

DateNo.

24202C001.DWG

09/30/2025

AS NOTED

2024-0202.00

© 2024 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF CMTA ASSOCIATES, INC AND ANY REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN PERMISSION.

CONSTRUCTION DOCUMENTS

600 South Orlando Ave | Maitland, FL 32751

407.332.5110 | cmta.com

MELBOURNE COURTHOUSE

LIGHTNING PROTECTION

PROJECT LOCATION:

51 NIEMAN AVE #100,

MELBOURNE, FL 32901

CONSTRUCTION DOCUMENTS

09/30/2025

PROJECT LOCATION:

AREA MAP VICINITY MAP

SHEET INDEX:

C001 COVER SHEET

E001 GENERAL NOTES AND LEGEND - ELECTRICAL

E002 SPECIFICATIONS - ELECTRICAL

E101 LIGHTNING PROTECTION - ROOF PLAN

E401 DETAILS ELECTRICAL

COVER SHEET

MLB

KGL

C001

This item has been digitally signed and sealed by Kyriakos Liatsos, PE on the date adjacent to the seal.

Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.

SCALE: NTS

File Name:

Checked By:

Project Number:

Date:

Drawn By:

Sheet Title:

Project Title:

Client:

Seal:

Scale:

Description

M

EL

BO

U

R N

E C

O U

R

TH

O U

SE

LI

G H

TN

IN

G P

R O

TE

C

TI

O

N

N

IE

M

AN

A

VE

0, M

EL

BO

U

R N

E, F

L

DateNo.

24202E001.DWG

09/30/2025

AS NOTED

2024-0202.00

© 2024 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF CMTA ASSOCIATES, INC AND ANY REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN PERMISSION.

CONSTRUCTION DOCUMENTS

600 South Orlando Ave | Maitland, FL 32751

407.332.5110 | cmta.com

GENERAL NOTES AND

LEGEND - ELECTRICAL

MLB

KGL

E001

This item has been digitally signed and sealed by Kyriakos Liatsos, PE on the date adjacent to the seal.

SCALE: NTS Drawing Number:

File Name:

Checked By:

Project Number:

Date:

Drawn By:

Sheet Title:

Project Title:

Client:

Seal:

Scale:

Description

M

EL

BO

U

R N

E C

O U

R

TH

O U

SE

LI

G H

TN

IN

G P

R O

TE

C

TI

O

N

N

IE

M

AN

A

VE

0, M

EL

BO

U

R N

E, F

L

DateNo.

24202E002.DWG

09/30/2025

AS NOTED

2024-0202.00

© 2024 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF CMTA ASSOCIATES, INC AND ANY REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN PERMISSION.

CONSTRUCTION DOCUMENTS

600 South Orlando Ave | Maitland, FL 32751

407.332.5110 | cmta.com

SPECIFICATIONS - ELECTRICAL

MLB

KGL

E002

This item has been digitally signed and sealed by Kyriakos Liatsos, PE on the date adjacent to the seal.

SCALE: 1/8"=1'-0"

Drawing Number:

File Name:

Checked By:

Project Number:

Date:

Drawn By:

Sheet Title:

Project Title:

Client:

Seal:

Scale:

Description

M

EL

BO

U

R N

E C

O U

R

TH

O U

SE

LI

G H

TN

IN

G P

R O

TE

C

TI

O

N

N

IE

M

AN

A

VE

0, M

EL

BO

U

R N

E, F

L

DateNo.

24202E101.DWG

09/30/2025

AS NOTED

2024-0202.00

© 2024 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF CMTA ASSOCIATES, INC AND ANY REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN PERMISSION.

CONSTRUCTION DOCUMENTS

600 South Orlando Ave | Maitland, FL 32751

407.332.5110 | cmta.com

LIGHTNING PROTECTION -

ROOF PLAN

MLB

KGL

E101

This item has been digitally signed and sealed by Kyriakos Liatsos, PE on the date adjacent to the seal.

SCALE: NTS

File Name:

Checked By:

Project Number:

Date:

Drawn By:

Sheet Title:

Project Title:

Client:

Seal:

Scale:

Description

M

EL

BO

U

R N

E C

O U

R

TH

O U

SE

LI

G H

TN

IN

G P

R O

TE

C

TI

O

N

N

IE

M

AN

A

VE

0, M

EL

BO

U

R N

E, F

L

DateNo.

24202E401.DWG

09/30/2025

AS NOTED

2024-0202.00

© 2024 THESE PLANS AND THE INFORMATION SHOWN HEREIN ARE THE PROPERTY OF CMTA ASSOCIATES, INC AND ANY REPRODUCTIONS, DISCLOSURES OR USE THEREOF IN WHOLE OR IN PART IS EXPRESSLY PROHIBITED WITHOUT WRITTEN PERMISSION.

CONSTRUCTION DOCUMENTS

600 South Orlando Ave | Maitland, FL 32751

407.332.5110 | cmta.com

DETAILS - ELECTRICAL

MLB

KGL

E401

This item has been digitally signed and sealed by Kyriakos Liatsos, PE on the date adjacent to the seal.

C001
24202C001-OCI
E001
24202E001-OCI
E002
24202E002-OCI
E101
24202E101-OCI
E401
24202E401-OCI
2025-09-30T11:24:03-0400
Kyriakos Liatsos P.E.
2025-09-30T11:24:10-0400
Kyriakos Liatsos P.E.
2025-09-30T11:24:12-0400
Kyriakos Liatsos P.E.
2025-09-30T11:24:15-0400
Kyriakos Liatsos P.E.
2025-09-30T11:24:17-0400
Kyriakos Liatsos P.E.

File details come from the government source that posted it. Updated .