ATTACHMENT A - Construction Drawings for New Anchors.pdf
PDF 3 MB Posted
- Attached to
- Roof Tie Back Testing & Inspection Federal contract opportunity
- Solicitation number
- 36C25220Q0551
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| S02 36C25220Q0551.pdf | ||
| ATTACHMENT B - Existing Anchor Details.pdf | ||
| ATTACHMENT C MAD DOL WD 15-4897 REV-11 12.23.19.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PARKING RAMP
BLDG #15
'D' WING
C
H
I
L
L
E
R
P
L
A
N
T
BLDG #19
C
W
I
G
A
N
G
B
SWITCHGEAR
LAUNDRY
EMER. GENERATOR
WELL
PUMPHOUSE
MENTAL
HEALTH
CLINIC
ENTRANCE
MAIN
/LOBBY
BLDG #7
BLDG #12
BLDG #1
BLDG #2
BLDG #13
BLDG #3
CENTER
BLDG #5
B
L
D
BLDG #4
ELEC.
VA KIDS
FENCE
ENTRANCE
OLD MAIN
BLDG #22
M
R
I
COMMUNITY LIVING CENTER
HOSPICE
MENTAL HEALTH
EMERGENCY
C
O
N
N
E
C
T
I
O
R
R
I
D
R
BLDG #27
BLDG #17
B
L
BLDG #14
L
SERVICE ENCLOSURE
C
O
N
T
R
A
C
T
R
P
R
K
I N
G
CONNECTING CORRIDOR
BLDG 21
ROOFTOP UNIT
SITE PLAN
Area 1
POC: Aslam Husain
9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321
12.3.19100% Construction Documents 12.3.19
Scope of Work- Area 3
Scope of Work-
Scope of Work- Area 2B
Area 2A Scope of Work-
'D' WING
CH
IL
LE
R
PL
AN
T
' W
IN
G
'A' WING
ENTRANCE
MAIN
/LOBBY
BLDG #5
BL
DG
BLDG #22
MRI
MENTAL HEALTH
EMERGENCY
CO
NNEC
TI
NG C
ORR
ID
OR
BL
DG
CONNECTING CORRIDOR
SCOPE OF WORK AREA 1
GI002
26 EXISTING TIE BACKS TO BE TESTED
BUILDING 22
TO BE INSTALLED ON EITHER ON ROOF
CONNECTING CORRIDOR-A
26 NEW TIE BACKS @ 10'-0 SPACING,
CONNECTING CORRIDOR-B
5 40 NEW TIE BACKS @ 10'-0 SPACING TO
CONNECTING CORRIDOR-C
34 EXISTING TIE BACKS TO BE TESTED
37 EXISTING TIE BACKS TO BE TESTED
BUILDING 1-DWING
BY OTHERS
SITE PLAN AREA 1
APPENDIX A-1,2 & B- FIG 2
APPENDIX A-1,2 & B- FIG 3
STARTING 3' FROM B22 W AND 4' E SIDE
BE INSTALLED ON EITHER SIDE OF ROOF
TYP.
TYP.
POC: Aslam Husain
9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321
12.3.19100% Construction Documents 12.3.19
BUILDING 1-A WING
SEE A101
BY OTHERS
BY OTHERS
TYP.
REMOVED FROM SCOPE
Revised - Tie Back Anchor Corridor B Count 1.21.2020
ACCOMPANYING AMENDMENT 36C252-20-R-0038 - 0002
N
G
BLDG #1
BLDG #13
BLDG #3
ENTRANCE
OLD MAIN
COMMUNITY LIVING CENTER
HOSPICE
B
L
BLDG 21
BLDG #15
ENTRANCE
MAIN
/LOBBY
CONNECTING CORRIDOR 6 NEW TIE BACKS TO BE INSTALLED
BUILDING 15- PARKING GARAGE TOWER
CONNECTING CORRIDOR-C
34 EXISTING TIE BACKS TO BE TESTED
4 NEW TIE BACKS TO BE INSTALLED
BUILDING 15- PARKING GARAGE TOWER
BUILDING 1-B WING
BUILDING 1-B WING CORE
BUILDING 1-C WING 4C ROOF
SEE A101
SITE PLAN AREA 2B
SITE PLAN AREA 2A
SEE A101
SEE A101
BUILDING 1-A WING
SEE A101
APPENDIX A-1,2 & B- FIG 9 APPENDIX A-1,2 & B- FIG 9
TYP.
TYP.
POC: Aslam Husain
9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321
12.3.19100% Construction Documents 12.3.19
OR
VERIFY WITH STRUCTURAL DETAILS
OR
VERIFY WITH STRUCTURAL DETAILS
TYP.
TYP.
BY OTHERS
SE
RV
IC
E
EN
CL
OS
UR
E
RO
OF
TO
P
UN
IT
SWITCHGEAR
LAUNDRY
EMER. GENERATOR
WELL
PUMPHOUSE
MENTAL
HEALTH
CLINIC
BLDG #7
BLDG #2
BLDG #13
BLDG #3
ELEC.
HOSPICE
BLDG #27
BLDG #17
BLDG #14
B
L
SERVICE ENCLOSURE
ROOFTOP UNIT
10 NEW TIE BACKS TO BE INSTALLED
BUILDING 2 (OLD)- LAUNDRY
SITE PLAN AREA 3
APPENDIX A-1,4 AND B- FIG 11
TYP. TYP.
TYP.
POC: Aslam Husain
9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321
12.3.19100% Construction Documents 12.3.19
BUILDING 2
3 NEW TIE BACKS TO BE INSTALLED
8 EXISTING TIE BACKS TO BE TESTED
BY OTHER (NOT SHOWN FOR CLARIFTY)
APPENDIX A-1,4 AND B- FIG 10
VHAMADAndriP Highlight Corrected to 3.
POC: Aslam Husain
9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321
12.3.19100% Construction Documents 12.3.19
BUILDING 1- ROOF PLANS
2 NEW TIE BACKS TO BE INSTALLED
APPENDIX B- FIG 6
16 NEW TIE BACKS TO BE INSTALLED
APPENDIX B- FIG 5
9 NEW TIE BACKS TO BE INSTALLED
APPENDIX B- FIG 8
35 NEW TIE BACKS SPACED 3'-0"
APPENDIX B- FIG 7
9 EXISTING TIE BACKS TO BE TESTED
13 NEW TIE BACKS TO BE INSTALLED
APPENDIX B- FIG 12
37 EXISTING TIE BACKS TO BE TESTED
10 NEW TIE BACKS TO BE FIELD
APPENDIX B- FIG 5
ATTACHED TO SLAB- TO BE INSTALLED
TYP.
TYP.
TYP.
TYP.
6'-0" SPACING @ APPROX 22' FROM
EAST EDGE
3'-0" SPACING
INSTALLED AND LOCATED AS REQUIRED
APPROX 5'-0" SPACING AND
INSTALLED APPROX CENTER OF ROOF
TYP.
LOCATED FURTHEST FROM PARAPET
3'-6" SPACING
5 NEW TIE BACKS TO BE INSTALLED
APPROX 3'-1/2" SPACING ON
7 1/2"JOISTS
B
A
C
G
D
TYP.
BY OTHERS
10 EXISTING TIE BACKS TO BE TESTED
BY OTHERS
B-WING ROOF
17 EXISTING TIE BACKS TO BE TESTED
B-WING ROOF
BY OTHERS
BY OTHERS
2 EXISTING TIE BACKS
TO BE TESTED BY OTHERS
APPENDIX A-1 & 3
APPENDIX A-1 & 3
APPENDIX A-1 & 3
APPENDIX A-1 & 3
APPENDIX A-1 & 3
APPENDIX A-1 & 3
ROOF ANCHOR DETAILS
A500
NO SCALE2
ROOF TIE BACK
ADHESIVE ANCHOR CONCRETE SLAB - TYPE
NO SCALE5
ROOF TIE BACK
ANCHOR STEEL CONSTRUCTION BRIDGING STEEL - TYPE
NO SCALE1
ROOF TIE BACK
BACKER PLATE CONCRETE JOIST - TYPE
NO SCALE3
ROOF TIE BACK
BACKER PLATE MINIMUM CONCRETE SLAB THICKNESS - TYPE
NO SCALE4
ROOF TIE BACK
WELDED TO STEEL CONSTRUCTION - TYPE
ROOF TIE BACK
LOCATION/SCHEDULE/ - TYPE
POC: Aslam Husain
9245 Calumet Ave. Suite 205, Phone: (219) 836-2120 Fax: (219) 836-1129 Munster, IN 46321
12.3.19100% Construction Documents 12.3.19 Rev #1 - Tie Back Schedule- Task 3 & 4, Corridor B Count 1.21.2020 as well as any design information specifically mentioned 1.24.2020 Revision 2 - Removed Guardian Anchors as Basis of Design
ALL REFERENCES TO GUARDIAN AS A BASIS OF
DESIGN ARE TO BE VOIDED AND BE REPLACED
BY REQUIREMENTS DEFINED ELSEWHERE IN
THE DRAWINGS AND SPECIFICATIONS.
ALL REFERENCES TO GUARDIAN AS A BASIS OF
DESIGN ARE TO BE VOIDED AND BE REPLACED
BY REQUIREMENTS DEFINED ELSEWHERE IN
THE DRAWINGS AND SPECIFICATIONS.
ALL REFERENCES TO GUARDIAN AS A BASIS OF
DESIGN ARE TO BE VOIDED AND BE REPLACED
BY REQUIREMENTS DEFINED ELSEWHERE IN
THE DRAWINGS AND SPECIFICATIONS.
ALL REFERENCES TO GUARDIAN AS A BASIS OF
DESIGN ARE TO BE VOIDED AND BE REPLACED
BY REQUIREMENTS DEFINED ELSEWHERE IN
THE DRAWINGS AND SPECIFICATIONS.
ALL REFERENCES TO GUARDIAN AS A BASIS OF
DESIGN ARE TO BE VOIDED AND BE REPLACED
BY REQUIREMENTS DEFINED ELSEWHERE IN
THE DRAWINGS AND SPECIFICATIONS.
ACCOMPANYING AMENDMENT 36C252-20-R-0038 - 0002
File details come from the government source that posted it. Updated .