Attachment_A_Bridge_Abutment_Plans.pdf

PDF 2 MB Posted

Attached to
WTRBA Central Creek Pedestrian Bridge - UPDATED
Solicitation number
Event 32701-14044 V2
Issued by
Marion County, Tennessee

About this file

Bridge Abutment Plans Summary

This document is a structural plans attachment for a bridge abutment project located within the jurisdiction of the City of Jackson, Tennessee. The project is designed in accordance with the International Building Code (IBC 2018) and applicable standards including ASCE 7-16, AISC 360-16, AWS D1.1-15, and various ACI specifications for concrete and reinforcement. The design criteria establish a Risk Category II classification with specific load requirements including pedestrian traffic loads of 100 PSF, maintenance vehicle loads of 5 KIP with 2 axles, ground snow load of 10 PSF, and ultimate wind speeds of 105 miles per hour at Exposure C. Seismic design parameters for Site Class D include an SS value of 0.741 and S1 value of 0.271, resulting in a Seismic Design Category D classification with a total base shear of 7.8 KIPS using the Equivalent Lateral Force Procedure with a steel ordinary concentrically braced frame system.

The contractor is responsible for obtaining all required building permits, scheduling inspections, and determining the erection procedure and sequence including all temporary shoring and bracing to ensure structural stability during construction. All shop drawings, project data, and samples must be submitted as specified in the construction documents. The contractor bears full responsibility for safety precautions complying with OSHA standards, coordination of all trade openings and penetrations with appropriate disciplines prior to construction, and verifying that construction material placement does not exceed design live loads per square foot.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GENERAL

1. THESE GENERAL NOTES REPRESENT AND/OR SUMMARIZE KEY PROJECT INFORMATION FOR THE DRAWING USER'S

CONVENIENCE. HOWEVER, ALL CONSTRUCTION DOCUMENTS SHOULD BE REVIEWED FOR FURTHER DETAILS AND

REQUIREMENTS.

2. WHERE REFERENCE IS MADE TO VARIOUS CODES, STANDARDS, AND TEST STANDARDS FOR MATERIALS, SUCH

STANDARDS SHALL BE AS SPECIFIED IN SECTION CODES AND STANDARDS.

3. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER GENERAL STRUCTURAL NOTES AND TYPICAL DETAILS. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ON THE

PROJECT.

4. TYPICAL DETAILS ARE NOT CUT ON DRAWINGS, BUT APPLY UNLESS NOTED OTHERWISE.

5. WHERE ANY DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL STRUCTURAL NOTES AND

SPECIFICATIONS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN.

6. ELEVATIONS SHOWN ARE RELATIVE TO THE TOP OF BRIDGE DECK ELEVATION (T/BRIDGE = 0' - 0"). FOR PROJECT

DIMENSIONAL CONTROL, SEE CIVIL DRAWINGS.

7. WORK THESE DRAWINGS WITH THOSE PREPARED BY OTHER DISCIPLINES: CIVIL, RETAINING WALL DESIGN

ENGINEER, ETC. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR ARCHITECTURAL, MECHANICAL, ELECTRICAL AND PLUMBING WITH APPROPRIATE TRADES, DRAWINGS AND SUBCONTRACTORS PRIOR TO CONSTRUCTION. DO NOT PENETRATE ANY STRUCTURAL ELEMENTS (BEAMS, COLUMNS, WALLS, SLABS, STEEL DECKS, ETC.) WITHOUT PRIOR WRITTEN APPROVAL OF STRUCTURAL ENGINEER UNLESS SPECIFIC PENETRATION

DETAILS ARE SHOWN ON DRAWINGS.

8. THIS PROJECT IS WITHIN THE JURISDICTION OF THE CITY OF JACKSON, TENNESSEE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL BUILDING PERMITS AND SCHEDULING/ACCOMMODATING ALL REQUIRED

INSPECTIONS PERTAINING TO THE BUILDING PERMITS.

9. SUBMIT SHOP DRAWINGS, PROJECT DATA AND SAMPLES AS SPECIFIED ON CONSTRUCTION DOCUMENTS.

10. THE CONTRACT STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE, WHICH IS

DESIGNED TO BE SELF-SUPPORTING AND STABLE AFTER THE CONSTRUCTION IS FULLY COMPLETED. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE AND ENSURE THE STABILITY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES THE ADDITION OF WHATEVER SHORING, TEMPORARY BRACING, ETC. THAT MAY BE NECESSARY. SUCH MATERIAL SHALL REMAIN THE

CONTRACTOR'S PROPERTY AFTER COMPLETION OF THE PROJECT.

11. THIS ENGINEER DOES NOT HAVE CONTROL OR CHARGE OF, AND SHALL NOT BE RESPONSIBLE FOR, CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES, OR PROCEDURES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY ACTS OR OMISSIONS OF THE CONTRACTOR, THEIR SUBCONTRACTORS, AND ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF THESE PERSONS TO CARRY OUT THE WORK IN

ACCORDANCE WITH THE CONTRACT DOCUMENTS.

12. THE CONTRACTOR IS RESPONSIBLE FOR SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK THAT CONFORMS WITH THE REGULATIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA)

SAFETY AND HEALTH STANDARDS FOR THE CONSTRUCTION INDUSTRY.

13. CONSTRUCTION MATERIAL SHALL BE SPREAD OUT IN SUCH A MANNER TO NOT EXCEED THE DESIGN LIVE LOAD

PER SQUARE FOOT OF THE AREA.

14. OPTIONS AND ALTERNATES ARE FOR THE CONTRACTOR'S CONVENIENCE. IF AN OPTION OR ALTERNATE IS CHOSEN, CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHANGES NECESSARY AND SHALL COORDINATE ALL

DETAILS.

CODES & STANDARDS

1. IBC 2018: INTERNATIONAL BUILDING CODE

2. ASCE 7-16: MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES

3. AISC 360-16: SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS

4. AWS D1.1-15: AMERICAN WELDING SOCIETY STRUCTURAL WELDING CODE

5. MNL-66-20: ACI DETAILING MANUAL

6. ACI 117-10: SPECIFICATION FOR TOLERANCES FOR CONCRETE

7. ACI 301-10: STANDARD SPECIFICATION FOR STRUCTURAL CONCRETE

8. ACI 318-14: BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE

9. ACI 347-04: STANDARD SPECIFICATION FOR FORMWORK FOR CONCRETE

10. CRSI-18: MANUAL OF STANDARD PRACTICE

11. ASTM A615-15ae1: STANDARD SPECIFICATION FOR DEFORMED AND PLAIN

CARBON STEEL BARS FOR CONCRETE REINFORCEMENT

12. ASTM C150-15: STANDARD SPECIFICATION FOR PORTLAND CEMENT

DESIGN CRITERIA

RISK CATEGORY II

A. DEAD LOAD SELF-WEIGHT

B. LIVE LOADS

A. PEDESTRIAN TRAFFIC 100 PSF

B. MAINTENANCE VEHICLE 5 KIP, 2 AXLES

C. SNOW LOAD

A. GROUND SNOW LOAD 10 PSF

B. FLAT ROOF SNOW LOAD 8.4 PSF

D. WIND LOADS

A. ULTIMATE WIND SPEED (3-SECOND GUST) 105 MILES PER HOUR

B. EXPOSURE C

E. SEISMIC LOADS

A. SITE CLASS D

B. SEISMIC DESIGN CATEGORY D

a. SS 0.741

b. S1 0.271

c. SDS 0.596

d. SD1 N/A *

C. SEISMIC FORCE RESISTING SYSTEM STEEL ORDINARY CONCENTRICALLY BRACED FRAMES

a. REDUNDANCY COEFFICIENT, ρ 1.3

b. RESPONSE MODIFICATION FACTOR, R 3.25

c. SEISMIC IMPORTANCE FACTOR, Ie 1.0

d. OVERSTRENGTH FACTOR, Ωo 2.0

e. SEISMIC RESPONSE COEFFICIENT, Cs 0.183

f. TOTAL BASE SHEAR, V=CsW 7.8 KIPS

D. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PROCEDURE

* SITE SPECIFIC GROUND MOTION ANALYSIS CONDITION ASSESSED - IN ACCORDANCE WITH ASCE 7-16, SECTION 11.4.8, THE STRUCTURAL SYSTEM MEETS THE EXCEPTION CRITERIA #2 WHERE THE Cs VALUE WAS DETERMINED ACCORDING TO EQ. 12.8.2 WHERE T<1.5Ts.

THE FOLLOWING ABBREVIATIONS MAY BE USED ON THE DRAWINGS:

A ROD ANCHOR ROD

A/E ARCHITECT & ENGINEER

AB ANCHOR BOLT

ACI AMERICAN CONCRETE INSTITUTE

ADDL ADDITIONAL

AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE

APVD APPROVED

ARCH ARCHITECTURAL/ARCHITECT

ASCE AMERICAN SOCIETY OF CIVIL ENGINEERS

ASTM AMERICAN SOCIETY FOR TESTING MATERIALS

AWS AMERICAN WELDING SOCIETY

B/ BOTTOM OF

BLDG BUILDING

BM BEAM

BOT BOTTOM

BRG BEARING

BTWN BETWEEN

CALC CALCULATION(S)

CHKD CHECKED

CHKRD CHECKERED

CIP CAST-IN-PLACE CONCRETE

CJ CONSTRUCTION/CONTROL JOINT

CJP COMPLETE JOINT PENETRATION

CL CENTERLINE

CLR CLEAR/CLEARANCE

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONN CONNECTION

CONT CONTINUOUS

COORD COORDINATE

CP CONCRETE PIER

CRSI CONCRETE REINFORCING STEEL INSTITUTE

CTR CENTER

CTRD CENTERED

CU CUBIC

DBA DEFORMED BAR ANCHOR

DBL DOUBLE

DEG DEGREES

DET DETAIL

DIA DIAMETER

DIAG DIAGONAL

DIR DIRECTION

DL DEAD LOAD

DP DRILLED PIER

DWG DRAWING

(E) EXISTING

EA EACH

EF EACH FACE

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ENGR ENGINEER

EOD EDGE OF DECK

EOG EDGE OF GRATING

EOR ENGINEER OF RECORD

EOS EDGE OF SLAB

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EXP EXPANSION

EXT EXTERIOR

FB FLAT BAR

FD FLOOR DRAIN

FDN FOUNDATION

FF FINISHED FLOOR

FFE FINISHED FLOOR ELEVATION

FG FINISHED GRADE

FIN FINISH

FLG FLANGE

FLR FLOOR

FND FOUNDATION

FRMG FRAMING

FRP FIBER REINFORCED PLASTIC

FS FAR SIDE

FT FOOT

FTG FOOTING

GA GAGE, GAUGE

GALV GALVANIZED (HOT DIP)

GL GIRT LINE

GR GUARDRAIL

GRTG GRATING

(H) HORIZONTAL BEAM ORIENTATION

HCA HEADED CONCRETE ANCHOR

HDR HEADER

HGR HANGER

HORIZ HORIZONTAL

HP HIGH POINT

HR HANDRAIL

HSB HIGH STRENGTH BOLT

IF INSIDE FACE

IBC INTERNATIONAL BUILDING CODE

ICC INTERNATIONAL CODE COUNCIL

ICF INSULATED CONCRETE FORM

ID INSIDE DIAMETER

IN INCH

INT INTERIOR

JST JOIST

JT JOINT

K KIP(S)

KB KNEE BRACE

KSF KIPS PER SQUARE FOOT

KSI KIPS PER SQUARE INCH

LLH LONG LEG HORIZONTAL (ANGLE)

LLV LONG LEG VERTICAL (ANGLE)

LSH LONG SIDE HORIZONTAL (HSS)

LSV LONG SIDE VERTICAL (HSS)

LB POUND

LF LINEAR FEET

LL LIVE LOAD

LOC LOCATION

LONG LONGITUDINAL

LP LOW POINT

LSH LONG SLOTTED HOLE

M MOMENT

MATL MATERIAL

MAX MAXIMUM

MC MOMENT CONNECTION

MCJ MASONRY CONTROL JOINT

MECH MECHANICAL

MFD MANUFACTURED

MFR MANUFACTURER

MIN MINIMUM

MISC MISCELLANEOUS

MSNRY MASONRY

MTD MOUNTED

MTL METAL

N&F NEAR AND FAR

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NS NEAR SIDE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OF OUTSIDE FACE

OPNG OPENING

OPP OPPOSITE

OSH OVERSIZED HOLE

OWJ OPEN WEB JOIST

P/T POST TENSIONED(ING)

PART PARTITION

PCF POUNDS PER CUBIC FOOT

PCI POUNDS PER CUBIC INCH

PE PROFESSIONAL ENGINEER

PENE PENETRATION

PERIM PERIMETER

PL PLATE

PLCS PLACES

PLF POUNDS PER LINEAR FOOT

PREFAB PREFABRICATED

PROJ PROJECTION

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT POINT

PVC POLYVINYL CHLORIDE

QTY QUANTITY

R RADIUS

RCP REINFORCED CONCRETE PIPE

RD ROOF DRAIN

REF REFERENCE

REINF REINFORCING

REQD REQUIRED

RET RETURN

REV REVISION

RO ROUGH OPENING

SC SLIP CRITICAL

SCHED SCHEDULE

SECT SECTION

SHT SHEET

SIB STRUCTURAL ISOLATION BREAK

SIM SIMILAR

SIP STRUCTURAL INSULATED PANEL

SJI STEEL JOIST INSTITUTE

SL SLOPE

SPCS SPACES

SPEC(S) SPECIFICATION(S)

SQ SQUARE

SR SAG ROD

SS STAINLESS STEEL

SSH SHORT SLOTTED HOLE

STD STANDARD

STIF STIFFENER

STL STEEL

STRUCT STRUCTURAL

SYM SYMMETRICAL

T/ TOP OF

T&B TOP AND BOTTOM

T&G TONGUE AND GROOVE

THK THICK

THRU THROUGH

TJ TRUSS JOIST

TP TOE PLATE

TRANS TRANSVERSE

TYP TYPICAL

UL UNDERWRITERS LABORATORIES

UNO UNLESS NOTED OTHERWISE

VERT VERTICAL

VIF VERIFY IN FIELD

W/ WITH

W/O WITHOUT

WCJ WALL CONTROL JOINT

WP WORKING POINT

WS WATERSTOP

WWR WELDED WIRE REINFORCEMENT

YD YARD

ABBREVIATIONS

SHOP DRAWINGS & SUBMITTALS

1. THE GENERAL CONTRACTOR WILL REVIEW AND STAMP ALL SHOP DRAWINGS AND PRODUCT DATA SUBMITTALS FOR

CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS PRIOR TO SUBMISSION. ANY SHOP DRAWINGS OF PRODUCT DATA NOT REVIEWED AND STAMPED BY THE GENERAL CONTRACTOR WILL BE RETURNED WITHOUT REVIEW.

2. ANY SHOP DRAWINGS NOT CHECKED AND INITIALED BY THE SUPPLIER/DETAILER PRIOR TO SUBMITTING FOR

ARCHITECTURAL AND ENGINEERING REVIEW, WILL BE RETURNED WITHOUT REVIEW.

3. THE CEC CONSTRUCTION DOCUMENTS MAY NOT BE REPRODUCED FOR USE AS SHOP DRAWINGS, UNLESS

APPROVED BY THE ENGINEER OF RECORD.

4. ELECTRONIC FILES OF CONSTRUCTION DOCUMENTS WILL NOT BE MADE AVAILABLE FOR USE AS SHOP DRAWINGS.

5. REFER TO INDIVIDUAL NOTES SECTIONS FOR ADDITIONAL SUBMITTAL REQUIREMENTS.

EXCAVATIONS

1. EXCAVATIONS SHALL BE IN ACCORDANCE WITH THE RECOMMENDATIONS OF THE PROJECT GEOTECHNICAL REPORT.

2. THE CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE SHORING OR SLOPING OF EXCAVATIONS TO MEET OSHA

REQUIREMENTS. DESIGN OF SHORING IS THE CONTRACTORS RESPONSIBILITY. EXCAVATIONS SHALL BE IN

ACCORDANCE WITH ALL LOCAL, STATE AND FEDERAL REGULATIONS.

3. BLASTING IS NOT PERMITTED.

4. ANY SURFACES DISTURBED DURING CONSTRUCTION SHALL BE GRADED TO MATCH SITE GRADING DRAWINGS.

5. POSITIVE SITE DRAINAGE SHALL BE PROVIDED AT ALL TIMES SO THAT WATER IS NOT ALLOWED TO POND IN

EXCAVATIONS OR NEAR FOUNDATIONS

6. ANY SOFT SPOTS ENCOUNTERED ON SITE SHALL BE REMOVED AND REPLACED WITH ENGINEERED FILL. REFER TO

GEOTECHNICAL REPORT FOR ADDITIONAL REQUIREMENTS.

7. EXCAVATIONS SHALL BE FREE OF STANDING WATER, ICE, DEBRIS, OR OTHER DELETERIOUS MATERIALS PRIOR TO

PLACING CONCRETE.

FOUNDATION NOTES

1. FOUNDATIONS ARE DESIGNED IN ACCORDANCE WITH THE FOLLOWING GEOTECHNICAL REPORT

A. PREPARER GOODWYN MILLS CAWOOD, LLC, OF NASHVILLE TN

B. PROJECT NUMBER GNAS250061

C. REPORT DATE MARCH 10, 2026

2. THE DESIGN PARAMETERS WERE PROVIDED FOR SOIL PROPERTIES AS NOTED BELOW:

A. FROST DEPTH 1.5 FT

B. BEARING CAPACITY 1,000 PSF (NET ALLOWABLE)

C. DENSITY OF SOIL 120 PCF (ABOVE WATER TABLE)

57.6 PCF (BELOW WATER TABLE)

D. MODULUS OF SUBGRADE REACTION N/A (0-5 FT, SOFT CLAY)

20 PCI (5-9 FT, LOOSE SAND)

30 PCI (9-17 FT, SOFT CLAY)

20 PCI (17-35 FT, LOOSE SAND)

E. EFF ANGLE OF INTERNAL FRICTION, Φ 29 DEGREES

F. AT-REST LATERAL SOIL PRESSURE COEFF, Ko 0.48 G. ACTIVE LATERAL SOIL PRESSURE COEFF, Ka 0.32 H. PASSIVE LATERAL SOIL PRESSURE COEFF, Kp 2.0

I. PASSIVE RESISTANCE 240 PCF (NEGLECT TOP 1 FOOT OF SOIL)

J. COEFFICIENT OF FRICTION 0.40 (BETWEEN BASE AND STIFF/MEDIUM DENSE SOIL)

0.50 (BETWEEN BASE AND COMPACTED SHOT ROCK)

3. GEOTECHNICAL ENGINEER TO BE RETAINED BY OWNER TO PROVIDE OBSERVATION AND TESTING SERVICES DURING

THE GRADING AND FOUNDATION PHASE OF CONSTRUCTION. INSPECTION AND TESTING REPORT SHALL BE

SUBMITTED TO THE ENGINEER OF RECORD.

4. PREPARE FOUNDATION SUBGRADE IN ACCORDANCE WITH THE REQUIREMENTS SPECIFIED IN THE PROJECT

GEOTECHNICAL REPORT.

5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE WHETHER OR NOT ADDITIONAL GEOTECHNICAL INFORMATION IS REQUIRED AND TO PROVIDE SUCH INFORMATION AS HE/SHE DEEMS NECESSARY.

6. PRIOR TO PLACEMENT OF CONCRETE, CONTRACTOR SHALL CONFIRM ALL FOUNDATION EMBED ITEMS - PIPES

SLEEVES, STEEL PLATES, INSERTS, ETC., ARE IN PLACE.

STRUCTURAL CONCRETE

1. CONCRETE WORK SHALL FOLLOW THE PRACTICES AND STANDARDS SPECIFIED IN SECTION CODES AND

STANDARDS.

2. CONCRETE PROPERTIES:

A. ALL CONCRETE SHALL CONFORM TO ASTM C94

B. ALL AGGREGATES SHALL CONFORM TO ASTM C33 (NORMAL-WEIGHT) & ACI 302.1

C. ALL CONCRETE SHALL BE CURED IN CONFORMANCE WITH ACI 301

D. ALL CONCRETE FORMWORK SHALL CONFORM WITH ACI 347

3. ADDITION OF WATER TO THE BATCH FOR MATERIAL WITH INSUFFICIENT SLUMP WILL NOT BE PERMITTED, UNLESS THE SUPPLIER HAS SPECIFICALLY WITHHELD WATER FROM THE BATCH AT THE PLANT. IN SUCH CASE, THE MIX DESIGN AND TRUCK TICKET MUST CLEARLY STATE THE MAXIMUM AMOUNT OF WATER THAT CAN BE ADDED TO THE BATCH ON SITE. IN NO CASE SHALL THE DESIGN WATER TO CEMENTITIOUS

MATERIAL RATIO BE EXCEEDED.

4. AGGREGATES DETERMINED TO BE ALKALI-CARBONATE REACTIVE (ACR), IN ACCORDANCE WITH ASTM

C1778, ARE NOT PERMITTED.

5. CONTRACTOR TO SUBMIT ALL PROPOSED CONCRETE ADMIXTURES TO EOR FOR APPROVAL.

6. CONTRACTOR AND REDI-MIX SUPPLIER TO SELECT A TARGET SLUMP BASED ON ASTM C143/C143M AS

PERMITTED UNDER ACI 301 FOR THE POINT OF DELIVERY FOR CONCRETE MIXTURES USED FOR THIS PROJECT. SELECTED TARGET SLUMP SHALL NOT EXCEED 9 INCHES. CONCRETE SHALL NOT SHOW VISIBLE SIGNS OF SEGREGATION. THE TARGET SLUMP INDICATED ON THE SUBMITTAL SHALL BE USED AS THE BASIS FOR ACCEPTANCE DURING THE PROJECT. SLUMP TOLERANCES SHALL BE IN ACCORDANCE WITH ACI 117.

7. MECHANICALLY VIBRATE ALL CONCRETE WHEN PLACED, EXCEPT THAT SLABS ON GRADE NEED TO BE VIBRATED ONLY AROUND UNDER-FLOOR DUCTS, SLAB EDGES, REINFORCING, KEYS, ETC. MECHANICALLY VIBRATE ONLY THE TOP 5 FEET OF DRILLED PIER CONCRETE. REVIBRATE TOP OF DRILLED PIER 15 MINUTES

AFTER PLACING CONCRETE.

8. VERTICAL CONCRETE SURFACES ARE TO BE FORMED.

9. ALL EXPOSED CONCRETE CORNERS (BOTH VERTICAL & HORIZONTAL) SHALL HAVE A 3/4" CHAMFER OR

ROUNDED TOOLED EDGE.

10. ALL CONCRETE SHALL CURE A MINIMUM OF 7 DAYS AFTER POURING, AND SHALL REMAIN UNLOADED UNTIL

CONCRETE HAS REACHED 80% OF THE 28 DAY DESIGN STRENGTH, UNLESS APPROVED BY THE ENGINEER

OF RECORD.

11. UNLESS OTHERWISE SPECIFIED, CONCRETE TEMPERATURE AS DELIVERED SHALL NOT EXCEED 95 DEGREES FAHRENHEIT NOR BE LESS THAN 55 DEGREES FAHRENHEIT FOR SECTION SIZE <12", 50 DEGREES FAHRENHEIT FOR 12" - 36". TEMPERATURE OF CONCRETE AS PLACED SHALL NOT EXCEED THESE VALUES

BY MORE THAN 20 DEGREES FAHRENHEIT.

12. ALKALI-SILICA REACTION - COMPLY WITH ONE OF THE FOLLOWING:

A. EXPANSION RESULT OF AGGREGATE: NOT MORE THAN 0.04 PERCENT AT ONE-YEAR WHEN TESTED IN

ACCORDANCE WITH ASTM 1293.

B. EXPANSION RESULTS OF AGGREGATE AND CEMENTITIOUS MATERIALS IN COMBINATION: NOT MORE

THAN 0.10 PERCENT AT AN AGE OF 16 DAYS WHEN TESTED IN ACCORDANCE WITH ASTM C1567.

C. ALKALI CONTENT IN CONCRETE: NOT MORE THAN 4 LB/YD3 FOR MODERATELY REACTIVE AGGREGATE

OR 3 LB/YD3 FOR HIGHLY REACTIVE AGGREGATE, WHEN TESTED IN ACCORDANCE WITH ASTM C1293

AND CATEGORIZED IN ACCORDANCE WITH ASTM C1778, BASED ON ALKALI CONTENT BEING

CALCULATED IN ACCORDANCE WITH ACI 301 (ACI 301M).

CONCRETE MIX REQUIREMENTS

CONCRETE

TYPE

28 DAY

COMPRESSIVE

STRENGTH

(f'c, PSI)

AIR CONTENT

(+/- 1.5%)

MAX W/C

RATIO

MAX NOM

AGG SIZE

(IN)

ALL CONCRETE

(UNO)

4,500 6.0% 0.45 3/4

CEMENT

TYPE

I/II

FLYASH %

(OF TOTAL

CEMENT)

10-20

EXPOSURE

CLASSES

F2, S0, W1, C1

REINFORCING STEEL

1. REINFORCING STEEL SHALL FOLLOW THE PRACTICES AND STANDARDS SPECIFIED IN SECTION CODES

AND STANDARDS.

2. TYPICAL REINFORCING BAR STRENGTHS

A. REINFORCING (NON-WELDABLE) ASTM A615, DEFORMED

Fy= 60 KSI (420 MPa)

B. REINFORCING (WELDABLE) ASTM A706, DEFORMED

Fy= 60 KSI (420 MPa)

3. CONCRETE COVER FOR REINFORCEMENT SHALL CONFORM TO THE REQUIREMENTS OF ACI 318 OR ACI

350, UNLESS OTHERWISE NOTED.

4. DETAILING, FABRICATION, SUPPORT, AND PLACING OF ALL BARS SHALL BE PER CRSI

SPECIFICATIONS/HANDBOOKS AND THE LATEST ACI CODES AND DETAILING MANUALS.

5. ALL REINFORCING SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES IN CONCRETE.

SECURELY TIE ALL BARS IN LOCATION BEFORE PLACING CONCRETE.

6. REINFORCING BAR SPACINGS GIVEN ARE MAXIMUM ON CENTERS.

7. REINFORCING BAR HOOKS AND BENDS SHALL BE ACI STANDARD DIMENSIONS, UNLESS NOTED

OTHERWISE.

8. REINFORCING BARS SHALL NOT BE BENT OR STRAIGHTENED IN A MANNER THAT WILL DAMAGE THE

MATERIAL. BARS WITH KINKS OR IMPROPER BENDS SHALL NOT BE USED. NO BARS PARTIALLY EMBEDDED IN CONCRETE SHALL BE FIELD BENT, EXCEPT AS SHOWN ON THE DRAWINGS OR AS PERMITTED BY THE

ENGINEER.

9. NO REINFORCING STEEL SHALL BE FIELD BENT WITHOUT THE APPROVAL OF THE ENGINEER OF RECORD.

FIELD BENDING OF PLAIN REINFORCEMENT, IF PERMITTED, SHALL BE PERFORMED USING AN APPROVED AND APPROPRIATE SIZED PORTABLE HYDRAULIC DEVICE THAT MAKES ACI STANDARD RADIUS BENDS.

NO OTHER FIELD BENDING METHOD SHALL BE PERMITTED.

10. REINFORCING LAP SPLICES IN CONCRETE SHALL BE PER TYPICAL DETAILS UNLESS NOTED OTHERWISE.

ALL SPLICE LOCATIONS ARE SUBJECT TO APPROVAL. PROVIDE BENT CORNER BARS TO MATCH AND LAP

WITH HORIZONTAL BARS AT CORNERS AND INTERSECTIONS OF FOOTINGS AND WALLS.

11. ALL SPLICING OF REINFORCING BARS SHALL BE DONE BY LAPPING UNLESS OTHERWISE APPROVED. BARS SPLICED BY NON CONTACT LAP SPLICES IN FLEXURAL MEMBERS SHALL NOT BE SPACED TRANSVERSELY

FARTHER APART THAN ONE-FIFTH THE REQUIRED SPLICE LENGTH NOR 6 INCHES.

12. LAP SPLICE LENGTHS FOR DEFORMED BARS SHALL BE ACI 318 CLASS B TENSION LAP SPLICES UNLESS

OTHERWISE NOTED ON DESIGN DRAWINGS.

13. LAP SPLICES FOR ADJACENT BARS SHALL BE STAGGERED. STAGGERED SPLICE REQUIREMENTS DO NOT

APPLY TO BEAMS AND COLUMNS.

14. ALL SPLICES NOT DETAILED ON DESIGN DRAWINGS SHALL BE TAKEN AS TENSION LAP SPLICES.

15. DIMENSIONS GIVEN FOR BENT OR HOOKED BARS ARE OUT TO OUT.

REINFORCING CLEAR COVER TABLE

TYPE CONCRETE CLEAR COVER (IN)

PERMANENTLY EXPOSED TO OR CAST AGAINST EARTH 3

EXPOSED TO EARTH OR WEATHER (#5 OR SMALLER) 1 1/2

1 1/2

EXPOSED TO EARTH OR WEATHER (#6 OR LARGER)

NOT EXPOSED TO EARTH OR WEATHER (#11 OR SMALLER)

NOT EXPOSED TO EARTH OR WEATHER (#12 OR LARGER)

CONCRETE DEVELOPMENT/LAP SPLICE SCHEDULE (f'c = 4.5 KSI)

BAR SIZE

DEVELOPMENT LENGTH (IN)

4 18 24

BAR TYPE 1*

LAP SPLICE LENGTH, CLASS B (IN)

BAR TYPE 1*

5 23 30

6 27 36

7 40 52

8 45 59

9 51 67

CLEAR SPACING OF BARS BEING DEVELOPED OR LAP SPLICED NOT LESS THAN Db, CONCRETE COVER NOT LESS THAN Db, AND STIRRUPS OR TIES THROUGHOUT Ld NOT LESS THAN THE CODE MINIMUM.

STRUCTURAL STEEL

1. ALL STRUCTURAL STEEL SHALL FOLLOW THE PRACTICES AND STANDARDS SPECIFIED IN SECTION CODES AND

STANDARDS.

2. ALL STRUCTURAL STEEL SHALL BE FABRICATED BY A FABRICATOR WITH ANY ONE OF THE FOLLOWING MINIMUM

QUALIFICATIONS. QUALIFICATIONS SHALL BE IN EFFECT AT TIME OF BID.

A. INTERNATIONAL ACCREDITATION SERVICE, INC. (IAS) APPROVED FABRICATOR.

B. AISC CERTIFIED FABRICATOR (STD).

C. FABRICATOR SHALL SUBMIT DOCUMENTATION OF THEIR CERTIFICATION WITH THE FIRST SHOP DRAWING

SUBMITTAL.

3. UNLESS OTHERWISE NOTED, THE SHOP DRAWING REVIEW TIME WILL BE IN ACCORDANCE WITH SECTION 4.4 OF THE

AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES.

THE WORD "APPROVED" IN SECTION 4.4 IS REDEFINED AS "REVIEWED".

4. STEEL PROPERTIES (UNLESS NOTED OTHERWISE):

A. WIDE FLANGE COLUMNS, BEAMS, CHANNELS AND TEES: ASTM A992 (FY = 50 KSI)

5. PROVIDE POSITIVE CAMBER AS NOTED ON DRAWINGS. WHERE NO CAMBER IS NOTED, RESIDUAL MILL CAMBER IS TO BE

UPWARDS.

6. STANDARD AISC "USUAL GAGE" DIMENSIONS SHALL BE USED FOR LOCATING HOLES FOR BOLTS, EXPANSION

ANCHORS, ETC. IN ALL ANGLES, BEAM FLANGES, ETC., UNLESS NOTED OTHERWISE.

7. WELDS SHALL BE MADE WITH E-70XX ELECTRODES. MINIMUM FILLET WELD SIZE SHALL BE 3/16" OR IN ACCORDANCE WITH AISC MANUAL TABLE J2.8, WHICHEVER IS GREATER. USE PREQUALIFIED WELDED JOINTS PER AISC AND THE AMERICAN WELDING SOCIETY (AWS). NON-PREQUALIFIED JOINTS SHALL BE SUBMITTED FOR

APPROVAL PRIOR TO FABRICATION.

8. EVERY STRUCTURAL PIECE IS TO INCLUDE IDENTIFICATION AS FOLLOWS:

A. UNIQUE PERMANENT PIECE IDENTIFICATION MARKING SUCH AS PUNCH OR WELD - ON TWO FACES.

B. UNIQUE PIECE IDENTIFICATION 2D BARCODED LABEL - ON TWO FACES.

C. IDENTIFIER OF PIECE ORIENTATION TO ASSIST STEEL ERECTOR.

9. ALL STEEL EXPOSED TO WEATHER SHALL BE HOT-DIPPED GALVANIZED AND PAINTED. WELDS FOR EXTERIOR STEEL EXPOSED TO WEATHER SHALL BE CONTINUOUS TO SEAL CONTACT SURFACES AND SHALL BE SEAL WELDED WHERE

STRUCTURAL WELDS ARE NOT SPECIFIED.

10. WHERE STEEL IS GALVANIZED, ALL WELDED JOINTS ARE TO BE SEAL WELDED CONTINUOUSLY. SEAL WELD BETWEEN

INTERMEDIATE WELDS SHOWN AND BETWEEN WELDED CONNECTION ANGLES AT BEAM ENDS.

11. SUBSTITUTION OF MATERIAL SIZE OR SHAPE IS PROHIBITED WITHOUT THE APPROVAL OF THE ENGINEER OF RECORD.

12. THE STEEL ERECTOR SHALL CORRECT MINOR MISALIGNMENTS BY APPLYING MODERATE AMOUNTS OF REAMING, CHIPPING, OR CUTTING AND BY DRAWING MEMBERS INTO LINE WITH THE USE OF DRIFT PINS. MISALIGNMENTS WHICH CANNOT BE CORRECTED BY THE FORGOING MEANS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER OF

RECORD.

13. TEMPORARY SUPPORTS SUCH AS BRACES, GUYS, FALSE WORK, AND CRIBBING SHALL BE DESIGNED, SUPPLIED, AND

INSTALLED BY THE STEEL ERECTOR TO ENSURE A SAFE ERECTION OPERATION.

14. ANY DISCREPANCIES OR INTERFERENCES FOUND BY THE STRUCTURAL STEEL DETAILER SHALL BE BROUGHT TO THE

ATTENTION OF THE ENGINEER OF RECORD PRIOR TO DETAILING STEEL.

A

B

34567 12

C

D

E

F

G

H

8 34567 12

A

B

C

D

E

F

G

H

R E

V

IS

IO

N

R

E C

O R

D

SHEET OF

D A

T E

D W

G S

C A

L E

D R

A W

N B

Y

C H

E C

K E

D B

Y

A P

P R

O V

E D

B Y

P R

O J E

C T

N O

DRAWING NO.:

C he ro ke e Fa rm W ay

Su ite

K no xv ill e, T

N

Ph : 8

.9

.9 w w w .c ec in c.

co m

C iv il

E nv ir o nm en ta l C o ns ul ta nt s, In c.

E N

G

IN

E E

R

IN

G S

U R

V E

Y

IN

G A

N D

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

I N

T H

E S

T A

T E

O F

N O

R T

H C

A R

O L

IN

A W

IL

L B

P

O V

ID

E

D B

Y C

E C

S U

R V

E Y

IN

G

A N

D L

A N

D S

C A

P E

A R

C H

IT

E

C T S

O F

N C

P

L L C

S

E R

V

IC

E S

I N

P U

E R

T O

R

IC

O W

IL

L

O V

ID

E

D B

Y C

E C

E N

G

IN

E E

R S

C

O N

S U

L T A

N T S

L L C

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

S E

R V

IC

E

S I N

T H

E S

T A

T E

O F

H

IO

W

IL

L B

E P

R O

V

ID

E D

B Y

C E

C L

A N

D S

C A

P E

A R

C H

IT

E

C T

S L L C

C U s e rs b c ri s c o k e s tn e r\ D o c u m e n ts S tr u c tu ra l_ C E N T R A L R b c ri s c o k e s tn e r.

rv t

N T

S

W E

S T

T E

N N

E S

S E

E

R

IV

E R

B A

S

IN

A U

T H

O R

IT

Y

U R

B A

N

S T

R E

A M

R E

S T

O R

A T

IO

N

C E

N T

R A

L C

R E

E K

J A

C K

S O

N T

E N

N E

S S

E E

S T

R U

C T

U R

A L

G E

N E

R A

L N

O T

E S

S C

M

R T

J /G

R G

B C

K

-0

A P

R

IL

S100 1 4

N O

D A

T E

D E

S C

R

IP

T

IO

N

/2

/2

R

E V

F O

U N

D A

T

IO

N C

H A

N G

E T

O S

H A

L L O

W F

O O

T

IN

G

8/21/26

STATEMENT OF SPECIAL INSPECTIONS

THIS STATEMENT OF SPECIAL INSPECTIONS IS SUBMITTED AS A CONDITION FOR PERMIT ISSUANCE IN ACCORDANCE WITH THE SPECIAL INSPECTION AND STRUCTURAL TESTING REQUIREMENTS OF THE BUILDING CODE. IT INCLUDES A SCHEDULE OF SPECIAL INSPECTION SERVICES APPLICABLE TO THIS PROJECT, AS WELL AS THE NAME OF THE SPECIAL INSPECTOR TO BE BE RETAINED FOR CONDUCTING THESE INSPECTIONS AND TESTS. THIS STATEMENT OF SPECIAL INSPECTIONS ENCOMPASSES THE FOLLOWING DISCIPLINES:

□ ARCHITECTURAL □ STRUCTURAL

□ MECHANICAL/ELECTRICAL/PLUMBING □ OTHER:

THE SPECIAL INSPECTOR SHALL KEEP A RECORD OF ALL INSPECTIONS AND SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL AND THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. DISCOVERED DISCREPANCIES SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF SUCH DISCREPANCIES ARE NOT CORRECTED, THE DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL AND THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE. THE SPECIAL INSPECTION PROGRAM DOES NOT RELIEVE THE CONTRACTOR OF HIS OR HER RESPONSIBILITIES.

INTERIM REPORTS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL AND THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE.

A FINAL REPORT OF SPECIAL INSPECTIONS DOCUMENTING THE COMPLETION OF ALL REQUIRED SPECIAL INSPECTIONS, TESTING, AND CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS SHALL BE SUBMITTED PRIOR TO ISSUANCE OF A CERTIFICATE OF USE AND OCCUPANCY.

JOB SITE SAFETY AND MEANS AND METHODS OF CONSTRUCTION ARE SOLELY THE RESPONSIBILITY OF THE CONTRACTOR.

THIS STATEMENT OF SPECIAL INSPECTIONS INCLUDES THE FOLLOWING BUILDING SYSTEMS:

□ ARCHITECTURAL □ SOILS □ CAST-IN-PLACE FOUNDATION ELEMENTS

□ DRIVEN DEEP FOUNDATION ELEMENTS □ HELICAL PILE FOUNDATIONS □ CAST-IN-PLACE DEEP FOUNDATION ELEMENTS

□ CONCRETE CONSTRUCTION □ MASONRY CONSTRUCTION - LEVEL A □ MASONRY CONSTRUCTION - LEVEL B

□ STRUCTURAL STEEL CONSTRUCTION □ STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL

□ WOOD CONSTRUCTION □ SPRAY FIRE-RESISTANT MATERIALS □ MASTIC AND INTUMESCENT FIRE-RESISTANT COATINGS

□ EXTERIOR INSULATION AND FINISH SYSTEMS (EIFS) □ FIRE-RESISTANT PENETRATIONS AND JOINTS □ SMOKE CONTROL

□ WIND RESISTANCE □ SEISMIC RESISTANCE

THE FOLLOWING COMPONENTS ARE WIND-RESISTING COMPONENTS OR PART OF THE MAIN WIND-FORCE RESISTING SYSTEM AND ARE SUBJECT TO SPECIAL INSPECTIONS IN

ACCORDANCE WITH THE SPECIAL INSPECTION SCHEDULE:

THE FOLLOWING COMPONENTS ARE DESIGNATED SEISMIC SYSTEMS OR PART OF THE SEISMIC-FORCE RESISTING SYSTEM THAT ARE SUBJECT TO SPECIAL INSPECTIONS IN

ACCORDANCE WITH THE SPECIAL INSPECTION SCHEDULE:

SPECIAL INSPECTION AGENCY:

X

X

X

X

REQUIRED VERIFICATION AND INSPECTION OF SOILS (IBC 2018 TABLE 1705.6)

VERIFICATION AND INSPECTION REQUIRED

VERIFY MATERIALS BELOW SHALLOW

FOUNDATIONS ARE ADEQUATE TO ACHIEVE THE

DESIGN BEARING CAPACITY.

CONTINUOUS PERIODIC REFERENCED STANDARD IBC REFERENCE

1.

VERIFY EXCAVATIONS ARE EXTENDED TO

PROPER DEPTH AND HAVE REACHED PROPER

MATERIAL.

2.

YES X - -

-YES X

PERFORM CLASSIFICATION AND TESTING OF

COMPACTED FILL MATERIALS.

3. -YES X

VERIFY USE OF PROPER MATERIALS, DENSITIES AND

LIFT THICKNESSES DURING PLACEMENT AND

COMPACTION OF COMPACTED FILL.

4.

XYES -

PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE

SUBGRADE AND VERIFY THAT SITE HAS BEEN

PREPARED PROPERLY.

5.

-YES X

REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE FOUNDATION

ELEMENTS (IBC 2018 SECTION 1705.3)

VERIFICATION AND INSPECTION REQUIRED

SPECIAL INSPECTIONS AND VERIFICATIONS FOR

CONCRETE FOUNDATION CONSTRUCTION IN

ACCORDANCE WITH THE SPECIAL INSPECTION

SCHEDULE: CAST-IN-PLACE CONCRETE FOR THE

FOLLOWING FOUNDATION ELEMENTS:

CONTINUOUS PERIODIC REFERENCED STANDARD IBC REFERENCE

1.

A. ISOLATED SPREAD CONCRETE FOOTINGS -YES - - -

B. CONTINUOUS CONCRETE FOOTINGS SUPPORTING WALLS

C. CONCRETE FOUNDATION WALLS

-YES - - -

-YES - - -

REQUIRED VERIFICATION AND INSPECTION OF CONCRETE

CONSTRUCTION (IBC 2018 TABLE 1705.3)

VERIFICATION AND INSPECTION REQUIRED

INSPECT REINFORCEMENT, INCLUDING

PRESTRESSING TENDONS, AND VERIFY

PLACEMENT.

CONTINUOUS PERIODIC REFERENCED STANDARD IBC REFERENCE

1.

REINFORCING BAR WELDING:

a. VERIFY WELDABILITY OF REINFORCING BARS

OTHER THAN ASTM A706;

b. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16"; AND

c. INSPECT ALL OTHER WELDS

2.

YES X

ACI 318: CH 20, 25.2, 25.3,

26.6.1-26.6.3 1908.4

-YES X

AWS D1.4

ACI 318: 26.6.4

INSPECT ANCHORS CAST IN CONCRETE.3.

X

YES

X

ACI 318: 17.8.2 -

INSPECT ANCHORS POST-INSTALLED IN

HARDENED CONCRETE MEMBERS.a

a. ADHESIVE ANCHORS INSTALLED IN

HORIZONTALLY OR UPWARDLY INCLINED

ORIENTATIONS TO RESIST SUSTAINED

TENSION LOADS.

b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.a.

4.

-NO X

ACI 318: 17.8.2.4

ACI 318: 17.8.2

VERIFYING USE OF REQUIRED DESIGN MIX.5. -YES X ACI 318: Ch. 19, 26.4.3, 26.4.4

1904.1, 1904.2, 1908.2, 1908.3

PRIOR TO CONCRETE PLACEMENT, FABRICATE

SPECIMENS FOR STRENGTH TESTS, PERFORM

SLUMP AND AIR CONTENT TESTS, AND

DETERMINE THE TEMPERATURE OF THE

CONCRETE.

6.

XYES -

ASTM C172; ASTM C31; ACI

318: 26.4.5, 26.12 1908.10

INSPECT CONCRETE AND SHOTCRETE

PLACEMENT FOR PROPER APPLICATION

TECHNIQUES.

7.

XYES - ACI 318: 26.4.5 1908.6, 1908.7, 1908.8

VERIFY MAINTENANCE OF SPECIFIED CURING

TEMPERATURE AND TECHNIQUES.

8.

-YES X ACI 318: 26.4.7-26.4.9 1908.9

INSPECT PRESTRESSED CONCRETE:

a. APPLICATION OF PRESTRESSING FORCES.

b. GROUTING OF BONDED PRESTRESSING

TENDONS IN THE SEISMIC FORCE-

RESISTING SYSTEM.

9.

X

XNO - ACI 318: 26.10 -

INSPECT ERECTION OF PRECAST CONCRETE

MEMBERS

10. -NO X ACI 318: Ch. 26.9 -

VERIFY IN-SITU CONCRETE STRENGTH, PRIOR

TO STRESSING OF TENDONS IN POST-

TENSIONED CONCRETE AND PRIOR TO REMOVAL

OF SHORES AND FORMS FROM BEAMS AND

STRUCTURAL SLABS.

11. -NO X ACI 318: 26.11.2 -

INSPECT FORMWORK FOR SHAPE, LOCATION

AND DIMENSIONS OF THE CONCRETE MEMBER

BEING FORMED.

12.

-YES X ACI 318: 26.11.1.2(b) -a SPECIFIC REQUIREMENTS FOR SPECIAL INSPECTION SHALL BE INCLUDED IN THE RESEARCH REPORT FOR THE ANCHOR ISSUED BY AN APPROVED SOURCE IN ACCORDANCE WITH 17.8.2 IN ACI 318, OR OTHER QUALIFICATION PROCEDURES. WHERE SPECIFIC REQUIREMENTS ARE NOT PROVIDED, SPECIAL INSPECTION REQUIREMENTS SHALL BE SPECIFIED BY THE REGISTERED DESIGN PROFESSIONAL AND SHALL BE APPROVED BY THE BUILDING OFFICIAL PRIOR

TO THE COMMENCEMENT OF THE WORK.

X

X

A

B

34567 12

C

D

E

F

G

H

8 34567 12

A

B

C

D

E

F

G

H

R E

V

IS

C

O R

D

SHEET OF

D A

T E

D W

G S

C A

L E

D R

A W

N B

Y

C H

E C

K E

D B

Y

A P

P R

O V

E D

B Y

P R

O J E

C T

N O

DRAWING NO.:

C he ro ke e Fa rm W ay

Su ite

K no xv ill e, T

N

Ph : 8

.9

.9 w w w .c ec in c.

co m

C iv il

E nv ir o nm en ta l C o ns ul ta nt s, In c.

E N

G

IN

E E

R

IN

G S

U R

V E

Y

IN

G A

N D

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

I N

T H

E S

T A

T E

O F

N O

R T

H C

A R

O L

IN

A W

IL

L

O V

ID

E

D B

Y C

E C

S U

R V

E Y

IN

G

A N

D L

A N

D S

C A

P E

A R

C H

IT

E

C T S

O F

N C

P

L L C

S

E R

V

IC

E S

I N

P U

E R

T O

R

IC

O W

IL

L

O V

ID

E

D B

Y C

E C

E N

G

IN

E E

R S

C

O N

S U

L T A

N T S

L L C

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

S E

R V

IC

E

S I N

T H

E S

T A

T E

IO

W

IL

L B

E P

R O

V

ID

E D

B Y

C E

C L

A N

D S

C A

P E

A R

C H

IT

E

C T

S L L C

C U s e rs b c ri s c o k e s tn e r\ D o c u m e n ts S tr u c tu ra l_ C E N T R A L R b c ri s c o k e s tn e r.

rv t

N T

S

W E

S T

T E

N N

E S

S E

E

R

IV

E R

B A

S

IN

A U

T H

O R

IT

Y

U R

B A

N

S T

R E

A M

R E

S T

O R

A T

IO

N

C E

N T

R A

L C

R E

E K

J A

C K

S O

N T

E N

N E

S S

E E

S T

R U

C T

U R

A L

S P

E C

IA

L

I N

S P

E C

T

IO

N S

S C

M

R T

J /G

R G

B C

K

-0

A P

R

IL

S101 2 4

N O

D A

T E

D E

S C

R

IP

T

IO

N

/2

/2

R

E V

F O

U N

D A

T

IO

N C

H A

N G

E T

O S

H A

L L O

W F

O O

T

IN

G

1' - 0" 13' - 3" 13' - 3" 13' - 3" 13' - 3" 1' - 0"

B R

ID

G

E W

ID

T H

S200

BRIDGE ABUTMENT

(TYP)

TYP

TYP

(T

Y P

RETAINING WALL - BY OTHERS

*CONTRACTOR TO COORD

W/RETAINING WALL VENDOR TO

INCLUDE IN BID/CONSTRUCTION

FUTURE PEDESTRIAN BRIDGE (TBD)

55' - 0"

RETAINING WALL - BY OTHERS

*CONTRACTOR TO COORD

W/RETAINING WALL VENDOR TO

INCLUDE IN BID/CONSTRUCTION

RETAINING WALL - BY OTHERS

*CONTRACTOR TO COORD

W/RETAINING WALL VENDOR TO

INCLUDE IN BID/CONSTRUCTION

S300

13' - 0" (TYP)

ABUTMENT FOUNDATION

(TYP)

S300

6' - 0" 2' - 0" 5' - 0"

T/BRIDGE

0"

B/BEAM

-2' - 8 3/4"

26' - 6"26' - 6"

FUTURE PEDESTRIAN BRIDGE (TBD)

BRIDGE ABUTMENT

(TYP) - SEE PLAN

APPROX STREAM BED

PROFILE - SEE CIVIL

53' - 0"

T/ABUTMENT

-3' - 0"

8"53' - 8"8"

55' - 0"

ABUTMENT FOUNDATION

(TYP) - SEE PLAN

B/ABUTMENT

-11' - 3"

S300

A

B

34567 12

C

D

E

F

G

H

8 34567 12

A

B

C

D

E

F

G

H

R E

V

IS

C

O R

D

SHEET OF

D A

T E

D W

G S

C A

L E

D R

A W

N B

Y

C H

E C

K E

D B

Y

A P

P R

O V

E D

B Y

P R

O J E

C T

N O

DRAWING NO.:

C he ro ke e Fa rm W ay

Su ite

K no xv ill e, T

N

Ph : 8

.9

.9 w w w .c ec in c.

co m

C iv il

E nv ir o nm en ta l C o ns ul ta nt s, In c.

E N

G

IN

E E

R

IN

G S

U R

V E

Y

IN

G A

N D

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

I N

T H

E S

T A

T E

O F

N O

R T

H C

A R

O L

IN

A W

IL

L

O V

ID

E

D B

Y C

E C

S U

R V

E Y

IN

G

A N

D L

A N

D S

C A

P E

A R

C H

IT

E

C T S

O F

N C

P

L L C

S

E R

V

IC

E S

I N

P U

E R

T O

R

IC

O W

IL

L

O V

ID

E

D B

Y C

E C

E N

G

IN

E E

R S

C

O N

S U

L T A

N T S

L L C

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

S E

R V

IC

E

S I N

T H

E S

T A

T E

IO

W

IL

L B

E P

R O

V

ID

E D

B Y

C E

C L

A N

D S

C A

P E

A R

C H

IT

E

C T

S L L C

C U s e rs b c ri s c o k e s tn e r\ D o c u m e n ts S tr u c tu ra l_ C E N T R A L R b c ri s c o k e s tn e r.

rv t

/8

W E

S T

T E

N N

E S

S E

E

R

IV

E R

B A

S

IN

A U

T H

O R

IT

Y

U R

B A

N

S T

R E

A M

R E

S T

O R

A T

IO

N

C E

N T

R A

L C

R E

E K

J A

C K

S O

N T

E N

N E

S S

E E

S T

R U

C T

U R

A L

P L

A N

E

L E

V A

T

IO

N

S C

M

R T

J /G

R G

B C

K

-0

A P

R

IL

S200 3 4

3/8" = 1'-0"S200

1 BRIDGE STRUCTURAL PLAN

3/8" = 1'-0"S200

2 BRIDGE ELEVATION

PLAN NOTES

1. PEDESTRIAN BRIDGE STRUCTURE SHOWN WILL BE DESIGNED AND

ISSUED IN A FUTURE PHASE.

2. ALL ELEVATIONS SHOWN ON PLAN ARE RELATIVE TO THE TOP OF BRIDGE

(T/BRIDGE ELEV = 0' - 0"). CONTRACTOR SHALL COORDINATE ACTUAL

ELEVATIONS AND SLOPES WITH CIVIL DRAWINGS. NOTIFY EOR OF

DISCREPANCIES IMMEDIATELY AND PRIOR TO CONSTRUCTION.

3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS

PRIOR TO FABRICATION/CONSTRUCTION. NOTIFY EOR OF DISCREPANCIES

IMMEDIATELY AND PRIOR TO FABRICATION/CONSTRUCTION.

NORTH

N O

D A

T E

D E

S C

R

IP

T

IO

N

/2

/2

R

E V

F O

U N

D A

T

IO

N C

H A

N G

E T

O S

H A

L L O

W F

O O

T

IN

G

T/BRIDGE

0"

B/BEAM

-2' - 8 3/4"

T/ABUTMENT

-3' - 0"

6' - 0" BRIDGE WIDTH

RETAINING WALL - BY

OTHERS (SEE PLAN)

RETAINING WALL - BY

OTHERS (SEE PLAN)

ABUTMENT (TYP)

ABUTMENT LEDGE

(TYP)

3' - 11"

1" 1"

3' - 11"

FUTURE STEEL BEAM

FUTURE

BRIDGE DECK

FUTURE BASEPLATE AND

POST-INSTALLED ANCHORAGE

FUTURE STEEL LAMINATED

ELASTOMERIC BEARING

UPPER WALL REINF BEYOND

(2) #4 TIES @

ANCHORS (TYP)

ISOLATE ABUTMENT FROM

ADJACENT RETAINING WALL (TYP)

14' - 0"

T/BRIDGE

0"

B/BEAM

-2' - 8 3/4"

T/ABUTMENT

-3' - 0"

FUTURE PAVEMENT -

SEE CIVIL

FUTURE STEEL BEAMFUTURE

BRIDGE DECK

7"

6' - 0" 2' - 0" 5' - 0"

#5 HORIZ

@ 12" OC

1" GAP

FUTURE BASEPLATE AND

POST-INSTALLED ANCHORAGE

FUTURE STEEL LAMINATED

ELASTOMERIC BEARING

#57 STONE

BACKFILL - SEE

FOUNDATION NOTES

STRUCTURAL FILL -

SEE FOUNDATION

NOTES

B/ABUTMENT

-11' - 3"

13' - 0"

M

IN

8' - 0"

PERFORATED DRAIN TO

DAYLIGHT- SEE CIVIL

3"#6 VERT

@ 12" OC

LA

P

S P

L

IC

E

#5 HORIZ @

12" OC EF

#7 VERT @

12" OC EF

LA

P

S P

L

IC

E

3"

#7 @ 12" OC

T&B

#5 HORIZ @

12" OC T&B

(2) #4 TIES @

ANCHORS (TYP)

A

B

34567 12

C

D

E

F

G

H

8 34567 12

A

B

C

D

E

F

G

H

R E

V

IS

C

O R

D

SHEET OF

D A

T E

D W

G S

C A

L E

D R

A W

N B

Y

C H

E C

K E

D B

Y

A P

P R

O V

E D

B Y

P R

O J E

C T

N O

DRAWING NO.:

A S

S H

O W

N

C he ro ke e Fa rm W ay

Su ite

K no xv ill e, T

N

Ph : 8

.9

.9 w w w .c ec in c.

co m

C iv il

E nv ir o nm en ta l C o ns ul ta nt s, In c.

E N

G

IN

E E

R

IN

G S

U R

V E

Y

IN

G A

N D

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

I N

T H

E S

T A

T E

O F

N O

R T

H C

A R

O L

IN

A W

IL

L

O V

ID

E

D B

Y C

E C

S U

R V

E Y

IN

G

A N

D L

A N

D S

C A

P E

A R

C H

IT

E

C T S

O F

N C

P

L L C

S

E R

V

IC

E S

I N

P U

E R

T O

R

IC

O W

IL

L

O V

ID

E

D B

Y C

E C

E N

G

IN

E E

R S

C

O N

S U

L T A

N T S

L L C

L A

N D

S C

A P

E A

R C

H

IT

E C

T U

R E

S E

R V

IC

E

S I N

T H

E S

T A

T E

IO

W

IL

L B

E P

R O

V

ID

E D

B Y

C E

C L

A N

D S

C A

P E

A R

C H

IT

E

C T

S L L C

C U s e rs b c ri s c o k e s tn e r\ D o c u m e n ts S tr u c tu ra l_ C E N T R A L R b c ri s c o k e s tn e r.

rv t

W E

S T

T E

N N

E S

S E

E

R

IV

E R

B A

S

IN

A U

T H

O R

IT

Y

U R

B A

N

S T

R E

A M

R E

S T

O R

A T

IO

N

C E

N T

R A

L C

R E

E K

J A

C K

S O

N T

E N

N E

S S

E E

S T

R U

C T

U R

A L

S E

C T

IO

N

S A

N D

D E

T A

IL

S S

C M

R T

J /G

R G

B C

K

-0

A P

R

IL

S300 4 4

N O

D A

T E

D E

S C

R

IP

T

IO

N

/2

/2

R

E V

F O

U N

D A

T

IO

N C

H A

N G

E T

O S

H A

L L O

W F

O O

T

IN

G

3/4" = 1'-0"S300

2 REVISED ABUTMENT ELEVATION

3/4" = 1'-0"S300

1 REVISED ABUTMENT SECTION

Sheets
S100 - STRUCTURAL GENERAL NOTES
S101 - STRUCTURAL SPECIAL INSPECTIONS
S200 - STRUCTURAL PLAN & ELEVATION
S300 - STRUCTURAL SECTIONS AND DETAILS

File details come from the government source that posted it. Updated .