Attachment_7-Constitution_Museum_Specifications-Option_2.pdf
PDF 39 MB Posted
- Solicitation number
- 140P4326R0021
About this file
This is a construction specification document and drawing set for exterior window and door restoration work at the USS Constitution Museum (Buildings 22 and 28) located at Boston National Historical Park, Charlestown Navy Yard, Massachusetts. The project is being executed under National Park Service ownership with Schwartz/Silver Architects, Inc. serving as the prime architect and Building Conservation Associates, Inc. providing historic preservation expertise. Environmental Health & Engineering, Inc. is listed as the asbestos inspector for the project.
The specifications document contains comprehensive architectural drawings and repair schedules organized into multiple sheets covering sash removal and demolition plans for both buildings, elevation-specific restoration repair details for all four sides of each building, typical window and door conditions, window replacement details, masonry repair details, and itemized repair schedules for windows, doors, and masonry work by building and elevation. The drawing set includes 23 detailed sheets designed with CAD technology and dated February 10, 2025, providing contractors with complete technical documentation for restoration work involving removal, repair, and replacement of historic exterior windows and doors while addressing associated masonry repairs required to restore the buildings to appropriate historic standards.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT TEAM___________________________________________________________________________________________________
National Park Service -
Charlestown Navy Yard
OWNER
21 Second Ave Charlestown, MA 02129 tel: 617-242-5601
Building Conservation AssociatesHISTORIC PRESERVATION
10 Langley Road, Suite 202 Newton Centre, MA 02459 tel: 617-916-5661 x108 website: bcausa.com
Schwartz/Silver Architects, Inc.ARCHITECTS
75 Kneeland Street Boston, Massachusetts 02111 tel: 617-542-6650 fax: 617-951-0779 web site: www.schwartzsilver.com
Environmental Health & Engineering, Inc.ASBESTOS INSPECTOR
180 Wells Ave, Suite 200 Newton, MA 02459 tel: 781-247-4300 website: www.eheinc.com
194598
246267
TITLE OF SHEETSUB SHEET NO.DESIGNED:A/E FIRM
CADD:
TECH. REVIEW:
DATE:
PRIME:
SCHWARTZ/SILVER
ARCHITECTS, INC.
BOSTON, MA
SUBCONTRACTOR:
BUILDING
CONSERVATION
ASSOCIATES, INC.
NEWTON CENTRE,
MA
DRAWING NO.
PKG. NO.
SHEET
OF
COVER
A0.0 RESTORE EXTERIOR WINDOWS & DOORS,
USS CONSTITUTION MUSEUM (BUILDINGS
22 AND 28)02/10/2025
DRAWING LIST
A.0 COVER
AD1.1 BUILDING 22 SASH REMOVAL PLAN
AD1.2 BUILDING 22 SASH REMOVAL PLAN
AD1.3 BUILDING 22 SASH REMOVAL PLAN
AD1.4 BUILDING 22 SASH REMOVAL PLAN
AD1.5 BUILDING 28 SASH DEMOLITION PLAN
AD1.6 BUILDING 28 SASH DEMOLITION PLAN
A2.1 BUILDING 22 WEST ELEVATION RESTORATION REPAIRS
A2.2 BUILDING 22 NORTH ELEVATION RESTORATION REPAIRS
A2.3 BUILDING 22 EAST ELEVATION RESTORATION REPAIRS
A2.4 BUILDING 22 SOUTH ELEVATION RESTORATION REPAIRS
A2.5 BUILDING 28 WEST ELEVATION RESTORATION REPAIRS
A2.6 BUILDING 28 NORTH ELEVATION RESTORATION REPAIRS
A2.7 BUILDING 28 EAST ELEVATION RESTORATION REPAIRS
A2.8 BUILDING 28 SOUTH ELEVATION RESTORATION REPAIRS
A5.1 BUILDING 22 TYPICAL WINDOW CONDITIONS
A5.2 BUILDING 22 TYPICAL DOOR CONDITIONS - WEST
A5.3 BUILDING 22 TYPICAL DOOR CONDTIONS - SOUTH & EAST
A5.4 BUILDING 28 TYPICAL WINDOW CONDITIONS
A5.5 BUILDING 28 TYPICAL DOOR CONDITIONS
A5.6 BUILDING 28 WINDOW REPLACEMENT DETAILS
A5.7 MASONRY REPAIR DETAILS
A6.1 BUILDING 22 WINDOW REPAIR SCHEDULE
A6.2 BUILDING 22 DOOR REPAIR SCHEDULE
A6.3 BUILDING 22 MASONRY REPAIR SCHEDULE
A6.4 BUILDING 28 WINDOW REPAIR SCHEDULE
A6.5 BUILDING 28 DOOR REPAIR SCHEDULE
A6.6 BUILDING 28 MASONRY REPAIR SCHEDULE
RESTORE EXTERIOR WINDOWS & DOORS, USS CONSTITUTION MUSEUM
BUILDINGS 22 AND 28
kfrick Stamp
| A0.0 - COVER |
| AD1.1 22 Demo West |
| AD1.2 22 Demo North |
| AD1.3 22 Demo East |
| AD1.4 22 Demo South |
| AD1.5 28 Demo North South |
| AD1.6 28 Demo East West |
| A2.1 22 West |
| A2.2 22 North |
| A2.3 22 East |
| A2.4 22 South |
| A2.5 28 West |
| A2.6 28 North |
| A2.7 28 East |
| A2.8 South |
| A5.1 Window Conditions |
| A5.2 Door Conditions 1 |
| A5.3 Door Conditions 2 |
| A5.4 Window Conditions |
| A5.5 Door Conditions |
| A5.6 Window Replacement Details |
| A5.7 Masonry Repair Details |
| A6.1 Window Schedule |
| A6.2 Door Schedule |
| A6.3 Masonry Schedule |
| A6.4 Window Schedule |
| A6.5 Door Schedule |
| A6.6 Masonry Schedule |
File details come from the government source that posted it. Updated .