Attachment 6 Price Schedule 15 Dec 2020.xlsx

XLSX spreadsheet 73 KB Posted

Attached to
CANCELLED Maintenance & Repair (M&R) IDIQ, Luke AFB, AZ
Solicitation number
FA488721R0009
Issued by

View the file

Other files

File Type Posted
Solicitation Amendment FA488721R00090003.pdf PDF
Solicitation Amendment FA488721R00090002.pdf PDF
FA488721R0009 MR Consolidated RFI Responses Final 10 Feb 2021.xlsx XLSX spreadsheet
Solicitation Amendment FA488721R00090001 SF 30.pdf PDF
Attachment 2 Wage Determination AZ20210031 - Maricopa County - 1Jan2021.pdf PDF
Attachment 17 NAF Construction Clauses Definitions.pdf PDF
Attachment 14 Renovation Project Sustainment and Restoration 23Oct20.pdf PDF
Attachment 5 Ordering Procedures 15 Dec 2020.pdf PDF
Attachment 12 Fire System Criteria - 10Dec18.pdf PDF
Attachment 8 AFI 33-118 Electromagnetic Spectrum Management.pdf PDF
Attachment 4 PPQ and Cover Letter 17 Dec 2020.pdf PDF
Attachment 18 - Joint Venture Teaming Partner Consent Letter - 17 Dec 20.pdf PDF
Solicitation - FA488721R0009.pdf PDF
Attachment 7 Luke Master Specifications - 9Sep2020.pdf PDF
Attachment 11 AETC First 400 Feet Standard Guidance with Luke Supplemental 5May15 v4.pdf PDF
Attachment 20- Price Evaluation Worksheet - 28Dec20.xlsx XLSX spreadsheet
Attachment 3 Wage Determination AZ20210030 - Coconio County - 1Jan2021.pdf PDF
Attachment 9 Luke AFB Disc Submittal Guidelines.pdf PDF
Attachment 1 M and R SOW 5 Feb 2020.pdf PDF
Attachment 10 LUKE Design and Construction Standards.pdf PDF
Attachment 19 Sections L and M Instructions to Offerors and Evaluation Factors 31 Dec 2020.pdf PDF
Attachment 16 NAF Standard Clauses.pdf PDF
Attachment 15 Basic Project Design Requirements - 23Oct20.pdf PDF
Attachment 13 Luke Specification for Fire Protection and Life Safety - 6Jun15.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

MAINTENANCE AND REPAIR OF BUILDINGS
FACILITIES AND STUCTURES AT LUKE AFB, AZRSMeans Coefficient
PERFORMANCE PERIOD FIVE YEARS
0The Contractor shall furnish all plant, labor, equipment, tools, supplies and materials and perform all work necessary to perform maintenance and repair of buildings, facilities and structures at Luke AFB, Arizona, and it's GSU's in accordance with Statement of Work for period of performance: xx Apr 20 through xx Apr 25.ORDERING YEAR 1ORDERING YEAR 2ORDERING YEAR 3ORDERING YEAR 4ORDERING YEAR 5
ITEM #DESCRIPTIONQTYUNITUNIT COSTTOTALUNIT COSTTOTALUNIT COSTTOTALUNIT COSTTOTALUNIT COSTTOTAL
WOOD DOORS - INTERIOR
Flush solid door 2'-8" x 6'-8" thru 7'-0"
1Replace and paint wood interior, flush solid door 2'-8" x 6'-8" thru 7'-0"1EA
2Complete as above, with vision lights. Max 12SF of glass area1EA
3Complete as above with louvers to match existing or measure 10" or less than width of door and have a max height of 48"1EA
4Complete as above B Label fire (90 min) rated door1EA
Flush solid door 3'-0" X 6'-8" thru 7'-3"
5Replace and paint wood interior, flush solid door 3'-0" X 6'-8" thru 7'-3"8EA
6Complete as above, with vision lights Max 12 SF of glass area4EA
7Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"1EA
8Complete as above B Label fire (90 min) rated door1EA
9Replace and paint wood interior, flush solid Dutch doors 3'-0" x 6'-8" thru 7'-3"1EA
METAL DOORS - INTERIOR
Metal interior flush door 2'-6" x 6'-8" thru 7'-3"
10Replace and paint metal interior flush door 2'-6" x 6'-8" thru 7'-3"1EA
11Complete as above, with vision lights Max 12 SF of glass area1EA
12Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"1EA
13Complete as above B Label fire (90 min) rated door1EA
Metal interior flush door 2'- 8" X 6'- 8" thru 8'-0"
14Replace and paint metal interior flush door 2'- 8" X 6'- 8" thru 8'-0"1EA
15Complete as above, with vision lights Max 12 SF of glass area1EA
16Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"1EA
17Complete as above B Label fire (90 min) rated door1EA
Metal interior door 3' - 0" x 6' - 8" thru 8' - 0"
18Replace and paint metal interior door 3' - 0" x 6' - 8" thru 8' - 0"2EA
19Complete as above, metal clad door with vision lights, max 12 SF glass area2EA
20Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"2EA
21Complete as above B Label fire (90 min) rated door2EA
METAL DOORS - EXTERIOR
Metal exterior door 2'-6" x 6'-8" thru 8'-0"
22Replace and paint metal exterior door 2'-6" x 6'-8" thru 8'-0"2EA
23Complete as above, metal clad door with vision lights, max 12 SF glass area1EA
24Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"1EA
25Complete as above B Label fire (90 min) rated door1EA
Metal exterior door 2'-8" X 6'-8" thru 8'-0"
26Replace and paint metal exterior door 2'-8" X 6'-8" thru 8'-0"1EA
27Complete as above, metal clad door with vision lights, max 12 SF glass area1EA
28Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"1EA
29Complete as above B Label fire (90 min) rated door1EA
Metal exterior door 3'-0" x 6'-8" thru 8'-0"
30Replace and paint metal exterior door 3'-0" x 6'-8" thru 8'-0"4EA
31Complete as above, metal clad door with vision lights, max 12 SF glass area2EA
32Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"2EA
33Complete as above B Label fire (90 min) rated door2EA
Metal exterior door 3'-4" x 6'-8" thru 8'-0"
34Replace and paint metal exterior door 3'-4" x 6'-8" thru 8'-0"2EA
35Complete as above, metal clad door with vision lights, max 12 SF glass area1EA
36Complete as above, with louvers to match existing or to measure 10" or less than with width of door and have a max louver height of 48"1EA
37Complete as above B Label fire (90 min) rated door1EA
3'0" x 9'0" metal exterior flush door
38Replace & paint 3'0" x 9'0" metal exterior flush door1EA
39Complete as above with louvers to match (top & bottom) if applicable1EA
40Complete as above B Label fire (90 min) rated door1EA
METAL DOOR FRAMES
41Replace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 4'-0" x 8'-0"2EA
42Replace/paint single metal door frame, interior and exterior, B label fire (90min) rated maximum size 8'-0" x 8'-0"4EA
43Replace/paint single metal door frame, head and transom casings and stops as applicable maximum size 4'-0" X 8'-0"2EA
44Replace / paint double metal door frame, head and transom casings and stops as applicable maximum size 8' - 0" X 8' - 0"2EA
WOOD DOOR FRAMES
45Replace/paint single wood door frame, including casing and stops as applicable (maximum size 4'-0" X 8'-0")1EA
46Replace / paint double wood door frame, including casings and stops as applicable (maximum size 8' - 0" X 8' - 0")1EA
WOOD DOOR CASINGS/STOPS
Wood door casing
47Replace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 4'-0" x 8'-0"2EA
48Replace and paint wood single door casing clam shell type, maximum 11/16" x 2 1/4" single door openings (one side) size up to 8'-0" x 8'-0"2EA
Wood door stops
49Replace and paint wood door stops complete set for single wood door maximum size 4'-0"x 8'-0"2EA
50Replace and paint wood door stops complete set for double wood door maximum size 8'-0"x 8'-0"2EA
Door louvers
51Replace and paint wood door louvers Maximum 6 SF2EA
52Replace and paint metal door louvers Maximum 6 SF2EA
Refit Doors
53Refit interior wood single door and adjust hardware for proper operation1EA
54Refit interior wood double doors and adjust hardware for proper operation1EA
55Refit interior stairwell single wood or metal fire door and adjust hardware1EA
56Refit interior stairwell double wood or metal fire door and adjust hardware for proper1EA
57Refit exterior single wood or metal door and adjust hardware for proper operation1EA
58Refit exterior wood or metal double door and adjust hardware for proper operation1EA
59Refit exterior mechanical room metal double door and adjust for proper operation1EA
Replace entrance and store front door, includes trim and hardware, tempered glass
60Entrance front doors 3'-0" x 7'-0" Entrance Door Full1EA
61Entrance front doors 6'-0" x 7'-0" 1/2 Entrance Door Full1EA
62Entrance front doors 5'-0" x 7'-0" 1/2 Entrance Door Full1EA
Install automatic door openers for store front doors
63Complete as above, slider single1EA
64Complete as above, slider double1EA
65Complete as above, swinging single1EA
66Complete as above, swinging double2EA
HARDWARE - HEAVY DOORS
Replace mortise type lock set and keeper regular keying
67Medium Duty type2EA
68Heavy Duty type2EA
Replace cylinder latchsets
69Replace cylindrical type latch set (passage)6EA
70Replace cylindrical type latch set Knob SFIC6EA
71Replace cylindrical type latch set Lever SFIC6EA
Replace aluminum threshold for door
72Wood or metal door {Maximum size 3'}4EA
73Wood or metal door {Maximum size 6'}4EA
74Replace exit or panic device stainless steel or bronze as specified single door complete rim exit bolt includes pull with thumb piece and cylinder lock4EA
75Replace surface mounted door closer as required with regular arm Interior and exterior wood or metal doors4EA
76Replace full mortise hinges, ball bearing, extra heavy weight, non rising pin, size up and including 5" x 5" with steel pins, complete including screws steel pins8EA
77Remove existing hinges and install extruded hinge, anodized aluminum geared continuous hinge, thrust bearing, heavy weight, unhandled with finish as required (half surface)6EA
78Remove existing hinges and install extruded anodized aluminum geared continuous hinge, thrust bearing, heavy weight, unhandled with finish as required (half surface)2EA
79Replace surface mounted foot bolt zinc plated steel bolt, maximum length 6"2EA
80Replace surface mounted chain bolt zinc plated steel bolt, maximum length 6"2EA
81Replace floor mounted door stop, Aluminum2EA
Replace door holder, Aluminum
82Floor Mounted2EA
83Door Mounted2EA
84Replace astragal strip on double doors metal or wood (as applicable)2EA
85Replace threshold weather stripping door sweep, extruded aluminum slotted holes, with screws7EA
Replace kick plate, size 10" x 30" thru 38"
86Replace kick plate, size 10" x 30" thru 38" Aluminum8EA
87Replace kick plate, size 10" x 30" thru 38" Plastic8EA

88 Replace push plate on door, .050 thick 4" x 16" aluminum 2 EA

Replace combination push-pull plates on doors
89Replace combination push-pull plate on doors thick 4" x 16" Bronze2EA
90Replace combination push-pull plate on doors thick 4" x 16" Aluminum2EA
91Wire Glass Replace wire glass (1/4 thick polished clear in door maximum 10 SF2EA
CARPENTRY
Replace paint Gypsum and Paperless wall board
92Replace and paint Gypsum board wall board including taping, three coat of spackling, one coat of primer paint and two finish coat of paint 1" x 4' x 8' minimum 4' x 4'4,000SF
93As above, Fire rating of 5/8 " 1 hour160SF
94Replace & paint Paperless moisture and mold resistant wall board 1/2 x 4' x 8' DensAmor Plus or Equivalent (minimum 4' x 4')96SF
95Plaster Repair & paint Gypsum plaster (on metal, lath or masonry surface800SF
96Wood Base Replace & paint 1" x 6" wood base minimum 5 LF48LF
97Shoe Molding Replace & paint or finish shoe molding as required to match existing Minimum 5 LF48LF
EXTERIOR LUMBER
Replace & paint Exterior Lumber
98Replace & paint 1" x 4" exposed exterior lumber (minimum 5 LF)40LF
99Replace & paint 1" x 6" exposed exterior lumber (minimum 5 LF)48LF
100Replace & paint 2" x 4" exposed exterior lumber (minimum 5 LF)800LF
101Replace & paint 2" x 6" exposed exterior lumber (minimum 5 LF)40LF
102Replace & paint 2" x 8" exposed exterior lumber (minimum 5 LF)80LF
103Replace & paint 2" x 10" exposed exterior lumber (minimum 5 LF)80LF
104Replace & paint 2" x 12" exposed exterior lumber (minimum 5 LF)80LF
Wood Siding
105Replace & paint exterior vertical wood siding to match existing (minimum 8sf) nominal size 1" x 8"120SF
106Plywood - 5/8" T 111 Exterior Siding for use on shed doors in compliance with section 09550 of the specification32SF
Remove, dispose and install new plywood
107Replace Plywood 1/4"80SF
108Replace Plywood 1/2"320SF
109Replace plywood 3/4"1,600SF
KITCHEN CABINETS & COUNTER TOP UPH UNITS
110Cabinet / Kitchen Wall remove and replace upper kitchen cabinets with new wood cabinet to conform with existing configuration.16LF
111Cabinet / Kitchen Base remove and replace base kitchen cabinets with new wood cabinets to conform with existing configuration16LF
112Counter Top / Replace - replace complete counter top with Formica Laminate top, provide necessary end caps and cutout for kitchen sink in compliance with section 11450 of the specification24LF
113Edge Strip / Formic Laminate - replace edge strip to match existing in compliance with section 11450 of the specification16EA
MEDICINE CABINETS
Replace Medicine Cabinet
114Cabinet / Medicine - replace to match existing size in compliance with section 10800 of the specification1EA
115Cabinet / Medicine With Fluorescent Lights - replace to match existing size in compliance with section 10800 of the specification1EA
DOORS & MISC ITEMS (UPH) UNITS
116Threshold / Marble - replace marble threshold1EA
117Rod / Shower Curtain - replace to match existing shape and size1EA
ELECTRICAL MISC ITEMS (UPH) UNITS
118Smoke Detector / AC with built in battery backup4EA
119Exhaust Fan / Bathroom ceiling, 80 CFM with light - replace4EA
120Range Hood / Kitchen with Light - Replace existing range hood with color and size to match existing3EA
121Replace Thermostat / Programmable digital readout for heating and cooling4EA
PLUMBING - BATHROOM & KITCHEN ITEMS (UPH) UNITS
122Tub / Steel Recessed, White, 5' x 30" - replace2EA
123Shower Base / Fiberglass, White - replace with 30" x 30" minimum to 36" x 36" maximum includes strainer2EA
124Shower Valve - Replace with Chrome Finish Pressure balanced, single lever scald guard with adjustable temperature limit stop2EA
125Trip Waste / Toe Operated Brass, 1 1/2" - replace trip waste and overflow to include chrome face plate in compliance with section 15400 of the specification2EA
126Face Plate / Chrome - replace trip waste face plate2EA
127Vanity / Solid Wood, White - replace with size to match existing 20", 24"or 30" including sink top in compliance with section 10805 of the specification1EA
128Bathroom Faucet / Single Lever Chrome - replace complete to include pop up drain stop3EA
129Closet Flange / Cast Iron, 4" - replace flange using leading joint includes anchoring flange in place2EA
130Toilet / 1.6 Gal Flush, White - replace two piece close couple china toilet4EA
131Toilet / Tank Parts - replace all parts including valve Flush Valve W/Adjust-a- Flush Flapper Tank-to- hardware and chrome tank lever4EA
132Toilet / Seat, White Plastic - replace round toilet seat with cover to include new hardware4EA
133Sink / Kitchen, Stainless Steel, Self Rimming Double bowl size 33" x 22" x 6" depth replace including S.S brackets strains1EA
134Basket Strainer / Kitchen Sink, Stainless Steel - replace1EA
135Faucet / Kitchen, Single Lever, 8" Center Set With spray replace including new aerator1EA
136Utility Tub / Fiberglass, Size 25 1/4" x 22 3/4" including legs built in strainer and complete 4" laundry tub facet set1EA
137Faucet / Laundry, 4" Ledge Mount - replace complete set including all required hardware1EA
138Hose Spray / Kitchen Sink 48"- replace hose, nozzle and sprayer1EA
139Hose Bib / Frost Free, Wall Mounted, 1/2" x 8" Long1EA
Replace Hot Water Heater
140Water Heater / Gas, 40 Gallon - replace1EA
141Water Heater / Electric, 40 Gallon - replace in compliance with section 15400 of the specification1EA
FLOORING
142Patch concrete floor surfaces with Portland cement max size 6" thick x 2 SF20EA
143Replace rubber stair tread 13" wide x 48" 5/16 (Length typical)40EA
144Safety tread Replace aluminum safety tread8EA
Replace rubber or vinyl wall base
145As above 4" high (all colors)3,200LF
146As above 6" high (all colors)800LF
Remove/dispose of existing VCT & Install new vinyl composition tile
147Remove/dispose of existing VCT & Install new vinyl composition size 12" x 12" x 1/8 minimum 100 SF8,000SF
148Install vinyl composition tile, size 12" x 12" minimum 100 SF over existing flooring size 9: x 9" 1/8 or 12" x 12" x 1/88,000SF
149Replace aluminum edge strips5LF
150Replace vinyl plastic edge strips5LF
151Flooring / Replace Sheet Linoleum - installation shall be done in a fashion that will minimize floor seams all seams must conform to manufacturer's specification in compliance with section 09950 of the specification300SF
152Linoleum Heat Weld Seaming80LF
153Integral Cove Base80LF
FLOORING - CERAMIC / QUARRY
154Re-grout existing ceramic or quarry tile match existing minimum 2 SF240EA
Replace tile
155Replace ceramic tile cove base maximum 6" high16SF
156Replace ceramic tile bull nose trim maximum 6" x 12"16LF
157Replace quarry tile cove base 2" to 5" high 3/4 maximum thick400SF
158Replace quarry tile bull nose trim maximum 6" x 6" x 3/4 thick400LF
159Replace quarry tile {Maximum size tile 6" x6" x 3/41,200SF
160Replace ceramic tile maximum size tile 12" x12" x 3/4160SF
CARPET
Remove, provide and install carpet to include all necessary materials for the installation of adhesives, molding and strips
161Replace Carpet with Broadloom Carpet320SY
162Replace Carpet with Carpet Tiles (24"x24")1,600SY
CEILINGS
Replace suspended ceiling lay-in panels
163Replace 24" x 24" mineral fiber acoustical lay-in-panels in existing suspension systems maximum 3/4 thick patterns vary1,200SF
164Replace 24" x 48" mineral fiber acoustical lay-in-panels in existing suspension systems maximum 3/4 thick patterns vary800SF
165Replace 24" x 24" medium density insulated fiberglass ceiling panels in existing suspension systems maximum 3" thick R-13.6 patterns vary1,200SF
166Replace 24" x 48" medium density insulated fiberglass ceiling panels in existing suspension systems maximum 3" thick R-13.6 patterns vary800SF
167Remove and reinstall existing insulation when new grid system is installed640SF
168Replace foil faced, fiber glass insulation over suspended ceiling or between framing members. Distance between members to determine width of insulation 3 1/2" thru 6" full thick, 11" thru 15" wide R11 thru R19320SF
Replace Grid ceiling system
169Replace suspension system for exposed grid acoustical lay in panels T-bar for exposed grid, painted white, does not include tile 2' x 2' grid800SF
170Replace suspension system for exposed grid acoustical lay in panels T-bar for exposed grid, painted white, does not include tile 2' x 4' grid800SF
171Diffusers Replace aluminum air vent diffusers, 2' wide6EA
Provide and install new overlay porcelain veneer panel system, new clips and sub-frame system over existing deteriorated delaminated, rusted and /or missing window face panel New porcelain panels shall be secured to the existing extruded aluminum window panel frame in strict compliance with manufacturer's specifications. See drawing for details
172Porcelain veneer panel Provide new overlay porcelain veneer panel system 4' x 5'1EA
173Porcelain veneer panel Provide new overlay porcelain veneer panel system 4' x 7'1EA
174Porcelain veneer panel Provide new overlay porcelain veneer panel system 4' x 8'1EA
175Replace double glass window/door replace double strength glass in windows or doors maximum 9 SF8SF
176Glazing Compound Replace deteriorated blazing compound on metal or wood window sash16LF
ELECT RECEPTACLES/SWITCHES/BOX
Replace receptacle
177Receptacle / Wall, 15 Amp 125 Volt Duplex with ground replacement to include new plate. In compliance with section 16415 of the specification8EA
178Receptacle / 220 Volt for Range, Air Conditioner or Dryer replacement to include new plate in compliance with section 16415 of the specification1EA
179Receptacle / Ground Fault Circuit Interrupter - replace to include new plate in compliance with section 16415 of the specification2EA
Replace switch
180Switch / Single Pole - replace to include new plate. In compliance with section 16415 of the specification12EA
181Switch / Three Way - replace to include new plate. In compliance with section 16415 of the specifications2EA
182Switch / Dimmer - replace to include new plate. In compliance with section 16415 of the specification4EA
183Box, Electrical / Switch, Receptacle, Work or Junction. In compliance with section 16415 of the specification16EA
184Plate / Wall, Plastic - Replace Single, Double, Triple, combo or jumbo for GFI, Duplex receptacle or switch in compliance with section 16415 of the specification16EA
INTERIOR LIGHTING
Replace surface Ceiling mounted fluorescent
185Surface, Ceiling mounted fluorescent fixture size 2' x2' lensed, full flushed steel door Number lamps - 2 lamp type F32T8 Generic2EA
186Surface, Ceiling mounted fluorescent fixture size 2' x 4' lensed, full flushed steel door Number lamps -4' lamp type F32T8 Generic2EA
187Surface, Ceiling mounted fluorescent fixture size 1' x 4' wraparound lenses, Number lamps - 2 lamp type F32T8 Generic2EA
188Surface, Ceiling mounted fluorescent fixture size 2' x 4' wraparound lenses, Number lamps - 4' lamp type F32T8 Generic2EA
Replace Troffer drop in lights 2' x 2'
189Recessed Grid 2' x 2' Troffer, Static, Lensed, full flush steel door. Number lamps -2 lamp type F32T85EA
190Recessed Grid 2' x 2' Troffer, Static, Parabolic, Number lamps -2 lamp type F32T82EA
191Recessed Grid 2' x 4' Troffer, Static, Lensed, Number lamps -4 lamp type F32T85EA
192Recessed Grid 2' x 4' Troffer, Static, Parabolic, Number lamps -4 lamp type F32T82EA
193Open reflector, industrial (General Purpose) fixture, length 48" w/out lenses, number lamps- 2 lamp type F32T82EA
Replace Specification Grade Highboy
194Specification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminum prismatic acrylic reflector, lamp type - metal halide 250-400 MH1EA
195Specification Grade Highboy ,enclosed, pendant, integrally ballasted, industrial high intensity discharge fixture, cast aluminum prismatic acrylic reflector, lamp type -High Pressure Sodium 250-400 MH1EA
196Replace Exit Sign with energy efficient light emitting light emitting diode exit sign red color lettering2EA
Replace emergency light
197Replace emergency light 6 volt battery pack unit 2/two floodlights2EA
198Replace emergency light 2 x2 w/ battery back up2EA
199Remove and reinstall existing light fixture in accordance with the specifications2EA
Replace light fixture wiring
2001/2" EMT Conduit800LF
2013/4" EMT Conduit800LF
202Wiring MET Cable #12800LF
203Wiring MET Cable #10640LF
INTERIOR/EXTERIOR PREPARATION & PAINTING
Furnish all labor and material necessary to prepare and paint interior / exterior
204Surface preparation for extreme scraping, patching and cleaning of grease from surface to be painted40,000SF
205Pressure Washing furnish pressure wash of exterior building surfaces to remove dirt, oil, residues and other coating using a pump capable of 3000 PSI. Bleach solution shall be sprayed on from top to bottom allowed to yield and rinse to remove all bleach residue40,000SF
206Sandblast Masonry or Metal surfaces prior to painting1,600SF
207Bead Blast Masonry or Metal Surfaces prior to painting1,600SF
208Repair Cracks 1/2 - inch wide or larger but not to exceed 2" wide640LF
209Repair cracks and holes in all interior surfaces prior to painting Holes 1/2" diameter or larger but not to exceed 2" in diameter80LF
Furnish all labor and material necessary to paint interior surfaces
210Furnish all labor and material necessary to paint interior surfaces60,000SF
211Paint 1coat previously painted interior surface in accordance with specification60,000SF
212Each additional interior coat of paint in accordance with specification56,000SF
213Seal floor in accordance with specification2,000SF
214Apply 12-14 mil floor coating floor in accordance with specification2,000SF
215Apply 3-6 mil floor coating floor in accordance with specification2,000SF
216Apply non-skid surface in accordance with specification800SF
Refinish natural or stained wood surfaces with polyurethane or varnish (gloss or semi gloss) as applicable includes sanding and staining as required to match existing
217Paint 1 coat in accordance with specification16SF
218Each additional coat in accordance with specification16SF
Furnish all labor and material necessary to paint exterior surfaces
219Paint 1coat previously painted exterior surface in accordance with specifications60,000SF
220Each additional exterior coat of paint in accordance with specifications60,000SF
221STUCCO repair and paint stucco with Astec #900 non-hazardous, nontoxic non flammable heat barrier ceramic elastomeric coating compound, with 80% solar radiation400SF
Replace vinyl wall covering including wall preparation and or sizing compound
222Replace wall covering light weight (12-15 oz/SY) fabric backed800SF
223Replace wall covering medium weight (20-24 oz/SY) fabric backed800SF
224Replace wall covering heavy weight (28 oz/SY) fabric backed240SF
225Remove wall covering , skim coat and 1 coat of primer1,600SF
LATRINES
Replace Coated Metal Toilet Compartment- power coated bake enamel with finished thickness of doors and panels at 1" and pilasters at 1 1/4 " includes all hardware
226Size 36" x 66" with swing out door Single compartment (stand alone)1EA
227As above Two Compartments Adjacent1EA
228As above Three Compartments Adjacent1EA
229As above Four Compartments Adjacent1EA
230Size 60" X 66" with swing out door Wheelchair accessible1EA
Replace Solid plastic Toilet Compartment with 1" thick solid HDPE ( high density polyethylene) all panels and doors shall be fabricated of HDPE homogeneous in color and be 55" high includes all installation hardware
231Size 36" x 66" with swing out door1EA
232As above Two Compartments adjacent1EA
233As above Three Compartments adjacent1EA
234As above Four Compartments adjacent1EA
235Size 60" X 66" with swing out door wheelchair accessible1EA
Replace Commode complete installation with hardware
236Replace commode, siphon jet, elongated bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange1EA
237Replace ADA compliant commode, siphon jet, elongated bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange1EA
238Replace commode, siphon jet, regular bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange1EA
239Replace ADA compliant commode, siphon jet, regular bowl complete with flush valve with back-flow preventer and open or closed front seat without cover and floor flange1EA
240Reset commode and replace wax seal on commode1EA
241Rebuild flushometer using proper flushometer repair kit (commode & urinal)1EA
242Replace flushometer handle1EA
Replace toilet seat
243Replace commode seat for regular or elongated bowl, closed or opened front, less cover1EA
244Replace commode seat with cover for regular bowl with cover1EA
245Replace urinal wall hung type with flush valve and trap1EA
246Replace P-trap to urinal4EA
247Replace tail piece to urinal1EA
248Rehang urinal1EA
249Replace single compartment service or laundry sink max size 25" length, 24" width and 16" depth concrete or fiberglass, complete with faucet set, rubber stopper, chair, waste connection and stand 18" high3EA
250Replace lavatory (maximum size 24" x 20") complete with 4" combination faucet set to match existing with riser pipe and trap1EA
Replace Lavatory Faucet Set
251Replace lavatory 4" center-set faucet set to match existing with drain fitting with pop up drain, and riser piping1EA
252Replace lavatory 4" center-set faucet set to match existing with drain fitting with chair and stopper, and riser piping1EA
253Faucet / Repair - to include deck faucet, center set, tub & shower diverter and replacement of all washers and seats1EA
254Shower Stall, with drain only1EA
255Thermostatic Shower Valve1EA
256ADA Compliant 1 1/2" OD Grab Bar1EA
257ADA Compliant Fold up seat1EA
258Rehang existing lavatory1EA
259Replace swing type laundry or service sink faucet set to match existing1EA
260Replace tail piece to lavatory1EA
261Replace P-trap on lavatory or laundry sink to match existing1EA
LATRINES ACCESSORIES
262Replace shower faucet handle to match existing1EA
263Replace adjustable shower head {Vandal Resistant) 1/2 '' FIP female connection1EA
264Replace toilet paper holder to match existing chrome plated brass1EA
265Replace metal soap dish {to match existing chrome plated finish1EA
266Replace latrine mirror stainless steel frame and theft-proof hanging clips maximum size 36" x 24"2EA
267Replace 3" handicap stainless steel grab bar to include fasteners1EA
268Replace cast iron floor drain to match existing 4' outlet maximum2EA
269Replace perforated or slotted, brass chrome plated cover for existing floor drain 11" diameter maximum1EA
PLUMBING VALVES & PIPE (METAL)
270Valve / Stop, Chrome, Angle or Straight - replace with size 1/2 " sweat x 3/8 "OD compression or 3/8 I.P.S x 3/8 compression5EA
271Replace outside non-freeze faucet1EA
272Replace hose bib brass, with steel handle, either straight or angle body Maximum size 3/4 "1LF
Replace cooper water line
273Replace 1/2" copper water line16LF
274Replace 3/4" copper water line16LF
275Replace 1" copper water line24LF
276Replace 1 1/4" -1 1/2" copper water line4LF
277Replace 2" - 2 1/2" copper water line2LF
Replace pipe hanger
278Replace pipe hanger 1/2" thru 1"3EA
279Replace pipe hanger1 1/4" thru 1 1/2"2EA
280Replace pipe hanger 1 3/4" thru 2 1/2"2EA
Replace pipe covering insulation, fiberglass to match existing maximum 10 LF
281Replace pipe covering insulation, 1/2" thru 1" OD pipe20EA
282Replace pipe covering insulation, 2" thru 2 1/2 "OD pipe20EA
283Replace pipe covering insulation, 1" thru 1 1/2 "OD pipe20EA
284Replace pipe covering insulation, 3" thru 3 1/2 "OD pipe20EA
285Replace pipe covering insulation, 4" OD pipe20EA
Replace gate valve
286Replace bronze gate valve (1/2")1EA
287Replace bronze gate valve (3/4")1EA
288Replace bronze gate valve (1")2EA
289Replace bronze gate valve (1 1/2")2EA
290Replace bronze gate valve (2")2EA
291Replace bronze gate valve (2 1/2")2EA
PVC PIPE/FITTINGS
Replace PVC pipe
292Pipe / PVC, 1 1/2" Dia. Schedule 40 - replace, including any necessary hangers8LF
293Pipe / PVC, 2" Dia. Schedule 40 - replace, including any necessary hangers8LF
Replace PVC fitting
294Fitting / PVC, 1 1/2" Dia. Schedule 40 - replace one of the following coupling, adapter (male or female) 90 deg or 45deg elbow3EA
295Fitting / PVC, 2" Dia. Schedule 40 - replace one of the following coupling, adapter (male or female) 90 deg or 45deg elbow3EA
Replace PVC coupling
296Coupling / Fernco, 1 1/2" - replace2EA
297Coupling / Fernco, 2" - replace2EA
298Coupling / Fernco, 4" - replace2EA
299Supply Tube / Plastic - replace 3/8" OD or 1/2" OD plastic supply tube on lavatory, kitchen sink or toilet. In compliance with section 15400 of the specification2LF
300Trap / PVC "P", 1 1/4" or 1 1/2" - replace. In compliance with section 15400 of the specification2EA
301Tailpiece / PVC, 1 1/2" x 8" - replace flanged tailpiece, straight pr with dishwasher connection in compliance with section 15400 of the specification2EA
302Continuous Waste / PVC, 1 1/2" x 24" - replace with end or center outlet in compliance with section 15400 of the specification2EA
ROLL-UP AND SECTIONAL OVERHEAD DOORS
Replace steel overhead roll-up/Sectional doors 11' - thru 16' - 2"
303As above {Insulated} 9' 8" through 22' - 2" wide240SF
304As above {Un-insulated} 9' - 8" through 22' - 2" wide80SF
Replace aluminum overhead roll-up doors 11' - 8" thru 16' - 2" high
305As above {Insulated} 9'- 8" through 22'-2" wide240SF
306As above {Un-insulated} 9' - 8" through 22'- 2" wide80SF
Repairs/replacements for steel and/or aluminum sectional and roll-up doors.
307Replace door springs.1EA
308Replace cables1EA
309Replace electric door operators {chain or belt)2EA
310Replace electric door operator safety bottom edge2EA
311Repair/replace electric push button control2EA
312Repair/replace tracks2EA
313Replace hinges and rollers.2EA
314Replace neoprene internal hood baffles1LF
315Replace neoprene astragal1EA
316Replace vision panels1EA
317Replace weather stripping40LF
318Replace motor on operator1EA
319Replace complete operator1EA
EXTERIOR SIDING
Replace and/or cover existing surfaces, complete with vinyl siding and polystyrene insulating backer and all necessary trim, molding and fasteners for a complete job. Choice of color to be selected by QAR per delivery order
320Siding 8" w/backer80SF
321Siding dbl 4" w/backer800SF
322Siding vertical 10" w/backer16SF
323Outside corner post24LF
324Inside corner post16LF
325J panel96LF
326Starter strip (horizontal)96LF
327Drip cap96LF
328Soffit panel 10"32SF
329Soffit panel (perforated)96SF
330Starter strip (vertical)96LF
331Fascia panel 12"96LF
332Furring Strip 1" X 3"1,360LF
333Install 3/4" insulation Urethane rigid insulation1,360SF
SIDING OTHER THAN VINYL
334Aluminum Siding Panel .032" thick min corrugated or ribbed, color as specified160SF
335EFIS, 2" thru 4" thick with reinforcement, finish to match existing texture and painted to match existing color80SF
336Fascia Aluminum .032" thick min, 12" thru 20" color as specified200LF
GUTTERS AND DOWNSPOUTS
Repair/Replace Gutters, Downspouts
337Aluminum Gutters / Leaders Downspouts repair / rehang including all hardware & sealant as directed by QAR. Size 3" thru 5" in compliance with section 07600 of the specification160LF
338Aluminum Gutters / Leaders Downspouts replace with minimum .027 thickness including all hardware & sealant as directed by QAR. Size 3" thru 5" in compliance with section 07600 of the specification160LF
339Aluminum Gutters / Leaders Downspouts clean and flush size 3" thur5" in compliance with section 07600 of the specification160LF
340Gutter Hardware Replace - brackets, hangers and joints160LF
341Aluminum Gutters / Leaders Downspouts repair / rehang including all hardware & sealant as directed by QAR. Size 6" thru 8" in compliance with section 07600 of the specification40LF
342Aluminum Gutters, Commercial Box or "K" replace with minimum .032 thickness including all hardware & sealant as directed by QAR. Size 6" thru 8" in compliance with section 07600 of the specification640LF
343Downspout, Commercial Rectangular .025" thick min Aluminum, 3" x 4" brown, to include all elbows, connectors, and hardware400LF
344Aluminum Gutters / Leaders Downspouts repair / rehang including all hardware & sealant as directed by QAR. Size 10" thru 12" in compliance with section 07600 of the specification16LF
345Aluminum Gutters / Leaders Downspouts replace with minimum .032 thickness including all hardware & sealant as directed by QAR. Size 10" thru 12" in compliance with section 07600 of the specification16LF
346Aluminum Gutters / Leaders Downspouts clean and flush size 10" thru 12" in compliance with section 07600 of the specification16LF
347Gutter Hardware, Commercial Replace - brackets, hangers and joints160LF
MASONARY - INTERIOR
348Plaster - Replace / Repair wall or ceiling on metal lath or masonry surface. Repairs include replacement of lath, priming and painting of finished surface24SF
349Repair interior concrete or masonry surfaces (cracks, spalls, holes) larger than 2- inches24LF
350Replace deteriorated interior masonry block to match existing8EA
351Replace interior brick to match existing to include wall ties as required16EA
MASONRY - EXTERIOR
Fill cracks and fill holes in exterior surfaces with materials compatible with existing surfaces
352Cracks 1/2-inch wide or larger but not to exceed 2- inches in diameter60LF
353Holes 1/2 inch wide or larger but not to exceed 2 " in diameter64SF
354Surface (cracks, holes or spalls) larger than 2" minimum 6' SF60SF
355Apply masonry filler and sealer or apply metal primer to sandblasted surfaces as applicable960SF
356Remove deteriorated masonry from brick to block surfaces and repoint to conform with existing surfaces8EA
357Replace/apply caulking between similar or dissimilar interior or exterior construction material to include backup material as required200LF
ROOFING
Repair/Replace Asphalt Roofing system
358Replace asphalt shingles to match existing 25 sf minimum1,600SF
359ROOF CAP repair / replace metal roof cap96LF
Replace mineral surfaced rolled roofing to match existing
36090 PD Min Surface80SF
36190 PD Sol Edge80SF
362Steel Roofing corrugated or ribbed panel, 24 gauge min painted or zinc coated as specified800SF
363EPDM 45 mil, fully adhered or loose laid with ballast as directed640SF
364Built-Up Asphalt fully mopped 15 lb felt, number of plies, and surface finish to match existing roof (includes ballast if required)640SF
365Modified Bituminous Membrane fully mopped, 15 lb base with 150 mil cap, sheet surface to match existing roof640SF
CHAIN LINK FENCE
366Remove and dispose of existing fence 6'- 8' high800LF
Remove and install new chain link fence post
367Complete as above, end post 3"8EA
368Complete as above, corner post 4"8EA
369Complete as above, Line post single 2 1/2 in40EA
370Complete as above, Top rail 1 5/8 in800LF
Remove and install new chain link fence 9 gauge
371Replace 6' high 9 ga. Wire, galvanized chain link fence, single extension arm w/3 strands barb wire800LF
372Replace 8' high 9 ga. Wire, galvanized chain link fence, single extension arm w/3 strands barb wire400LF
Remove and Install new chain link fence gate
373Remove 12' double gate to include disposal 6' - 8' high1EA
374Remove 24' double gate to include disposal 6' - 8' high1EA
375Replace 12' double gate with 3 strains barbed wire, single extension arm 6" - 8" high1EA
376Replace 24' double gate with 3 strains barbed wire, single extension arm 6'' - 8" high1EA
Metal Privacy Fence
377Remove/Replace Slat on Metal Privacy Fence1EA
378Remove/Replace Post on Metal Privacy Fence1EA
379Remove/Replace Metal Privacy Fence Gate1EA
380Remove/Replace Metal Privacy Fence Rail1EA
381Remove/Replace Metal Privacy Fence1EA
Replace concrete and Bollards
382Complete as above, replace concrete2CY
383Replace Bollards, 6"2EA
MISC METAL WORK
Repair/replace radiator hardware
384Replace radiator, convector or register cover to match existing Maximum 5 LF4LF
385Rehang existing radiator or convector to include fasteners and brackets Maximum 5 LF4LF
386Replace aluminum air vent diffusers, 2' wide2EA
387Repair/replace double wall metal chimneys8LF
MISCELLANEOUS LABOR
Labor / Skilled - perform minor repairs as directed by QAR to include carpentry, electrical, plumbing and metal trades
388Perform miscellaneous minor carpentry work40HR
389Perform miscellaneous minor electrical work24HR
390Perform miscellaneous minor plumbing work24HR
391Perform miscellaneous labor work40HR
392Perform miscellaneous sheet metal work40HR
393Perform miscellaneous welding work8HR
394Move Furniture and Partition - Disassemble, Move, and Re-assemble to facilitate replacement of flooring/change-of-occupancy. Not to be used for lifting in place, movement of chairs, or furniture items not requiring assembly.224SF
ASBESTOS ABATEMENT
Complete Removal, all tests , monitoring, setups, notifications, material, labor and disposal of asbestos floor tile and insulation
395Asbestos floor tile and mastic Removal800SF
396Asbestos floor tile, mastic and carpet removal800SF
397Remove Asbestos pipe covering insulation, replace with equivalent fiberglass insulation up to 4" pipe40LF
398Remove Asbestos pipe covering insulation, replace with equivalent fiberglass insulation 4" thur 8" pipe16LF
399Remove Asbestos pipe covering insulation, replace with equivalent fiberglass insulation 10" thur 12" pipe8LF
400Remove Asbestos boiler covering insulation, replace with equivalent insulation24SF
401Remove Asbestos Duct or AHU covering insulation, replace with equivalent insulation16SF
402Remove Asbestos Transite Panels16SF
Mold Remediation
403Remove mold from contaminated surfaces800SF
404Replace Gypsum Board including taping, three coat of spackling, one coat of primer80SF
405Replace mold contaminated ceiling tiles80SF
406Replace mold contaminated Broadloom Carpet80SY
407Replace mold contaminated Carpet Tiles (24"x24")80SY
408Replace contaminated Cove Base800LF
409Replace contaminated fiberglass pipe insulation up to 4"80LF
410Replace contaminated fiberglass pipe insulation from 6" to 8"80LF
411Replace fiberglass insulation Batt or Roll80SF
412Clean carpet per IICRC S10080SY
413Perform cleaning of HVAC system to include: Air handlers, ducts, diffusers and registers.800SF
414Construct mold containment to include framing80SF
415Cover area with plastic sheeting400SF
416Replace HVAC Filter5EA
417Set-up AFU4EA
418Preliminary Visual Assessment Report
1EA
419Microbial Remediation Plan1EA
420Tape Test6Ea
421Air Sample Test4Ea
LEAD BASED PAINT ABATEMENT
422Pipe 0 to 4" diameter40LF
423Pipe 4" to 8"" diameter40LF
424Pipe 8" to 12"" diameter40LF
425Siding and other flat surfaces40SF
426Open Trusses40SF
427Collect, bag and dispose of bulk materials3EA
428Window Frames120SF
429Handrails80LF
HEAVY
430Clean Dysart Drainage Ditch - Remove vegetation1Mile
UTILITIES
431Exercise water distribution valves IAW PMTL D2025 140 1950 0116EA
432Flush Fire Hydrants IAW PMTL G3015 410 1950 018EA
433Clean Storm Drain Lines2,343LF
434Flush and Inspect Manhole & Sewer IAW PMTL G3025 544 1950 028EA
HVAC Maintenance and Repair
435Replace A/C air filters200EA
436Replace Air handler Belts40EA
437Replace Bearings8EA
438Replace Drain pan1EA
439Replace water drain line1LF
440Grease Bearings80EA
441Grease motor ports80EA
442Replace blower shaft1EA
443Replace condenser/evaporator fan motors (range from 1/4 - 2 hp)2EA
444Replace condenser/evaporator fan motors (range from 1/4 - 2 hp)2EA
445Replace blower wheel1EA
446Replace fan blades1EA
447Replace A/C compressor (2 ton)4EA
448Replace Refrigerant lines1LF
449Replace Chiller (20 ton/water cooled)1EA
450Replace Chiller (20 ton/air cooled)1EA
451Replace Chiller (50 ton/water cooled)1EA
452Replace Chiller (50 ton/air cooled)1EA
453Replace Chiller (100 ton/water cooled)1EA
454Replace Chiller (100 ton/air cooled)1EA
455Replace Chiller (5 ton/water cooled)1EA
456Replace Chiller (10 ton/water cooled)1EA
457Replace Chiller (15 ton/water cooled)1EA
458Replace Swamp cooler system1EA
459Replace chill water pump motors4EA
460Replace hot water pump motors4EA
461Replace boiler (Gas - 250 MBH)1EA
462Replace boiler (Gas - 2000 MBH)1EA
463Replace exhaust fan motors (Propeller Exh - 375 CFM)1EA
464Replace exhaust fan motors (Propeller Exh - 1000 CFM)1EA
465Replace exhaust fan motors (Propeller Exh - 4700 CFM)1EA
466Replace exhaust fan motors (Roof mounted - 800 CFM)1EA
467Replace exhaust fan motors (Roof mounted - 2000 CFM)1EA
468Replace exhaust fan motors (Utility Set belt drive - 800 CFM)1EA
469Replace exhaust fan motors (Utility Set belt drive - 3600 CFM)1EA
470Replace piping insulation1EA
471Replace A/C DX package unit (5 ton)1EA
472Replace A/C DX package unit (20 ton)1EA
473Replace contactor8EA
474Replace capacitor8EA
475Replace variable frequency drives1EA
476Replace condenser (air cooled 5 ton)1EA
477Replace condenser (air cooled 20 ton)1EA
478Replace condenser (air cooled 50 ton)1EA
479Replace evaporator (condenser 20 ton)1EA
480Replace evaporator (condenser 100 ton)1EA
481Replace PTAC (packaged terminal Air conditioner)(2 ton)2EA
482Replace ductless mini-split1EA
483Replace copper tubing1LF
484Replace filter driers4EA
485Replace refrigerant sight glass2EA
486Replace electric strip heaters1EA
487Replace air compressor1EA
488Replace PVC pipping (1-1/2")1LF
489Replace PVC pipping (2")1LF
490Replace PVC pipping (4")1LF
491Replace thermostat2EA
492Replace thermostat wiring1EA
493Replace temperature conrol module1EA
494Replace main circuit board1EA
495Replace display module1EA
496Replace actuators1EA
497Replace water flow switches1EA
498Replace relay4EA
499Replace sensor4EA
500Replace VAV box1EA
501Replace circulating water pump (1/12 hp)1EA
502Replace circulating water pump (1/2 hp)1EA
503Replace circulating water pump (1 hp)1EA
504Replace expansion tank (24 gal)1EA
505Replace expansion tank (60 gal)1EA
506Replace expansion tank (175 gal)1EA
507Replace expansion tank (400 gal)1EA
508Replace ductwork1LF
509Replace registers/diffusers1EA
510Replace pulley3EA
511Replace cooling tower (50 ton)1EA
512Replace cooling tower (100 ton)1EA
513Replace transformer4EA
514Replace actuators1EA
515Replace solid state overloads1EA
516Replace condensate pump2EA
517Install water flow switch for drain pans1EA
518Replace crankcase heater1EA
519Replace motor starters2EA
520Replace relays2EA
521Replace ball valve (less than 1-1/2")1EA
522Replace ball valve (2")1EA
523Replace discharge valve1EA
524Replace expansion valve2EA
525Replace gas valve1EA
526Replace refrigerant ball valves1EA
527Replace regulating valve1EA
528Replace reversing valve1EA
529Replace thermostatic expansion valve1EA
530Replace solenoid valve1EA
TOTAL0TOTAL0TOTAL0TOTAL0TOTAL0
CUMULATIVE TOTAL0

File details come from the government source that posted it. Updated .