Attachment 6 - Gate Design Black Jack CG.pdf
PDF 865 KB Posted
- Solicitation number
- 127EAX26Q0023
- Issued by
-
Department of Agriculture Forest Service
About this file
This is a technical specification document for a Gates and Cattle Guards Indefinite Delivery, Indefinite Quantity (IDIQ) contract for the Apache-Sitgreaves National Forests in Apache County, Arizona, under the U.S. Department of Agriculture Forest Service, R3 Southwestern Region. The document was updated on April 15, 2020.
The specification outlines fabrication and installation requirements for forest-wide gate and cattle guard systems. Single gate sets include one 16-foot swing gate, plate extension, hinge post, two Type 1 holding posts, lock tab, chain, slotted locking tab plate, and miscellaneous hardware for installation-ready delivery. Double gate sets include two 16-foot swing gates, two plate extensions, two hinge posts, one Type 2 holding post, one Type 1 holding post, two lock tabs and chains, two slotted locking tab plates, and miscellaneous hardware. Cattle guard fabrication requires all-steel construction (no concrete components permitted) meeting HS-20 loading standards and professional engineering documentation. All work must utilize Schedule 80 and Schedule 40 seamless and welded steel pipe per ANSI/ASME B36.10M-1995 standards. Gate installation requires 4,000 PSI concrete footings with ground-level drainage provisions. All exposed metal components must be primed with one coat of Benjamin Moore Retardo and painted with two coats of Benjamin Moore Impervio, Low Lustre in Federal Standard Color 20059. Installation must include 4 retroreflective orange stripes (6 inches wide) on all posts and bell housings. The contractor must provide at least 48 hours' advance notice prior to delivery, with delivery limited to Monday through Friday excluding federal holidays. All components, drawings, and calculations require professional engineering stamps and signatures.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SHEET OF
United States Department of Agriculture Forest Service
INDEX OF SHEETS
SHEET SHEET TITLE DATE
G-01 COVER SHEET 4/15/2020
G-02 SPECIFICATIONS 4/15/2020
A-01 16-FOOT GATE FABRICATION 4/15/2020
A-02 HINGE POST AND GATE ATTACHMENTS 4/15/2020
A-03 TYPE 1 AND TYPE 2 HOLDING POSTS 4/15/2020
A-04 GATE ACCESSORIES 4/15/2020
A-05 SINGLE GATE INSTALLATION 4/15/2020
A-06 DOUBLE GATE INSTALLATION 4/15/2020
A-07 ROAD CLOSURE GATE 4/15/2020
DATE
RECOMMENDED BY:
APPROVED:
FOREST ENGINEER
FOREST SUPERVISOR
DISTRICT RANGER DATE
DIRECTOR OF ENGINEERING DATE
RO FACILITIES PROGRAM MANAGER
DATE
DATE
GATES AND CATTLE GUARDS
STATE OF ARIZONA
APACHE COUNTY
APACHE-SITGREAVES NATIONAL FORESTS
R3 SOUTHWESTERN REGION
updated 04/15/2020
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/9 /20
:2
1 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\C
HR
IS
W
MI
LL
ER
\O
NE
DR
IV
E
- U
SD
A\
DO
CU
ME
NT
S\
CA
D
DE
TA
IL
S\
GA
TE
SA
ND
CA
TT
LE
GU
AR
DS
_2
5.D W
G;
R3
SOUTHWESTERN REGION
GATES AND CATTLE
GUARDS IDIQ
APACHE-SITGREAVES
NATIONAL FORESTS
FOREST-WIDE
SPECIFICATIONS
04/15/2020
R.POLANCO
R.POLANCO
C.MILLER
G-02
009002
SPECIFICATIONS
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text
1. WORK SUMMARY WORK SUMMARY 2. GATE FABRICATION GATE FABRICATION 2.1. DEGREASE AND REMOVE ALL DEBRIS PRIOR TO DEGREASE AND REMOVE ALL DEBRIS PRIOR TO PAINTING ALL METAL. 2.2. PRIME AND PAINT ALL EXPOSED METAL, INCLUDING PRIME AND PAINT ALL EXPOSED METAL, INCLUDING ALL GATE ACCESSORIES AND ATTACHMENTS. PRIME WITH ONE COAT OF BENJAMIN MOORE RETARDO, AND PAINT TWO COATS BENJAMIN MOORE IMPERVO, LOW LUSTRE, IN FEDERAL STANDARD COLOR 20059, OR EQUAL. 2.3. INCLUDE ONE QUART OF PAINT FOR FIELD TOUCH INCLUDE ONE QUART OF PAINT FOR FIELD TOUCH UP WITH EACH GATE FABRICATION. 2.4. INCLUDE ALL HARDWARE, BRACKETS, BOLTS, ETC. INCLUDE ALL HARDWARE, BRACKETS, BOLTS, ETC. FOR COMPLETE FIELD INSTALLATION. 2.5. REFERENCE ANSI/ASME B36.10M-1995 WROUGHT REFERENCE ANSI/ASME B36.10M-1995 WROUGHT STEEL PIPE SEAMLESS AND WELDED AND AMERICAN NATIONAL STANDARD SCHEDULES 40 AND 80 WELDED AND SEAMLESS STEEL PIPE. 3. GATE ORDERING GATE ORDERING 3.1. A SINGLE GATE SET SHALL INCLUDE: A SINGLE GATE SET SHALL INCLUDE: 3.1.1. ONE (1) 16-FOOT SWING GATE; ONE (1) 16-FOOT SWING GATE; 3.1.2. ONE (1) PLATE EXTENSION; ONE (1) PLATE EXTENSION; 3.1.3. ONE (1) HINGE POST; ONE (1) HINGE POST; 3.1.4. TWO (2) TYPE 1 HOLDING POSTS; TWO (2) TYPE 1 HOLDING POSTS; 3.1.5. ONE (1) LOCK TAB AND CHAIN; ONE (1) LOCK TAB AND CHAIN; 3.1.6. ONE (1) SLOTTED LOCKING TAB PLATE; ONE (1) SLOTTED LOCKING TAB PLATE; 3.1.7. ONE (1) QUART TOUCH-UP PAINT; ONE (1) QUART TOUCH-UP PAINT; 3.1.8. AND ALL OTHER MISCELLANEOUS GATE AND ALL OTHER MISCELLANEOUS GATE HARDWARE, NUTS, BOLTS, ETC. FOR INSTALLATION-READY. 3.2. A DOUBLE GATE SET SHALL INCLUDE: A DOUBLE GATE SET SHALL INCLUDE: 3.2.1. TWO (2) 16-FOOT SWING GATES; TWO (2) 16-FOOT SWING GATES; 3.2.2. TWO (2) PLATE EXTENSIONS; TWO (2) PLATE EXTENSIONS; 3.2.3. TWO (2) HINGE POSTS; TWO (2) HINGE POSTS; 3.2.4. TWO (2) TYPE 1 HOLDING POSTS; TWO (2) TYPE 1 HOLDING POSTS; 3.2.5. ONE (1) TYPE 2 HOLDING POST; ONE (1) TYPE 2 HOLDING POST; 3.2.6. TWO (2) LOCK TABS AND CHAINS; TWO (2) LOCK TABS AND CHAINS; 3.2.7. TWO (2) SLOTTED LOCKING TAB PLATES; TWO (2) SLOTTED LOCKING TAB PLATES; 3.2.8. TWO (2) QUARTS TOUCH-UP PAINT; TWO (2) QUARTS TOUCH-UP PAINT; 3.2.9. AND ALL OTHER MISCELLANEOUS GATE AND ALL OTHER MISCELLANEOUS GATE HARDWARE, NUTS, BOLTS, ETC. FOR INSTALLATION-READY. 4. GATE INSTALLATION GATE INSTALLATION 4.1. INSTALL ALL POSTS IN 4000 PSI FOOTING, WITH INSTALL ALL POSTS IN 4000 PSI FOOTING, WITH DIMENSIONS AS SHOWN; DOME CONCRETE ABOVE GROUND LEVEL TO PROVIDE DRAINAGE. 4.2. INSTALL GATE PLUMB AND LEVEL. INSTALL GATE PLUMB AND LEVEL. 4.3. INSTALL 4 RETRO REFLECTIVE ORANGE STRIPES, 6" INSTALL 4 RETRO REFLECTIVE ORANGE STRIPES, 6" WIDTH, EQUALLY SPACED, ON ALL POSTS. 4.4. INSTALL RETRO-REFLECTIVE ORANGE STRIPE ON INSTALL RETRO-REFLECTIVE ORANGE STRIPE ON ALL BELL HOUSINGS, ENTIRE OUTSIDE PERIMETER. 4.5. INSTALL TYPE 4, OM4-1 (MUTCD) DIAMOND WITH INSTALL TYPE 4, OM4-1 (MUTCD) DIAMOND WITH PLASTIC REFLECTORS. ONE ON EACH SIDE OF THE GATE, A TOTAL OF TWO PER GATE. 5. CATTLE GUARD FABRICATION CATTLE GUARD FABRICATION 5.1. ALL COMPONENTS OF THE CATTLE GUARD MUST BE ALL COMPONENTS OF THE CATTLE GUARD MUST BE STEEL (TO INCLUDE GRIDS, WINGS, FORMS/BEAMS, WINGS, ETC.) 5.2. CONCRETE COMPONENTS ARE NOT PERMITTED. CONCRETE COMPONENTS ARE NOT PERMITTED. 5.3. CATTLE GUARD MUST MEET HS-20 LOADING CATTLE GUARD MUST MEET HS-20 LOADING STANDARDS. 5.3.1. SUBMIT PROFESSIONAL ENGINEERING, STAMPED SUBMIT PROFESSIONAL ENGINEERING, STAMPED DRAWINGS AND CALCULATIONS. 5.3.2. PRIME AND PAINT ALL EXPOSED METAL, PRIME AND PAINT ALL EXPOSED METAL, INCLUDING ALL ACCESSORIES AND ATTACHMENTS. PRIME WITH ONE COAT OF BENJAMIN MOORE RETARDO, AND PAINT TWO COATS BENJAMIN MOORE IMPERVO, LOW LUSTRE, IN FEDERAL STANDARD COLOR 20059, OR EQUAL. 6. CATTLE GUARD ORDERING CATTLE GUARD ORDERING 6.1. A ONE-LANE CATTLE GUARD SET SHALL INCLUDE: A ONE-LANE CATTLE GUARD SET SHALL INCLUDE: 6.1.1. ONE (1) 15-FOOT CATTLE GUARD GRID ONE (1) 15-FOOT CATTLE GUARD GRID SECTION + FORMS/FOUNDATION; 6.1.2. TWO (2) WING ENDS; TWO (2) WING ENDS; 6.1.3. TWO (2) WING POSTS; TWO (2) WING POSTS; 6.1.4. AND ALL REQUIRED ALL-THREADS, NUTS, AND ALL REQUIRED ALL-THREADS, NUTS, BOLTS, WASHERS, ETC. FOR COMPLETE INSTALLATION. 6.2. A TWO-LANE CATTLE GUARD SET SHALL INCLUDE: A TWO-LANE CATTLE GUARD SET SHALL INCLUDE: 6.2.1. ONE (1) 15-FOOT CATTLE GUARD GRID ONE (1) 15-FOOT CATTLE GUARD GRID SECTION + FORMS/FOUNDATION; 6.2.2. ONE (1) 7.5-FOOT CATTLE GUARD GRID ONE (1) 7.5-FOOT CATTLE GUARD GRID SECTION + FORMS/FOUNDATION; 6.2.3. TWO (2) WING ENDS; TWO (2) WING ENDS; 6.2.4. TWO (2) WING POSTS; TWO (2) WING POSTS; 6.2.5. AND ALL REQUIRED ALL-THREADS, NUTS, AND ALL REQUIRED ALL-THREADS, NUTS, BOLTS, WASHERS, ETC. FOR COMPLETE INSTALLATION. 7. CATTLE GUARD INSTALLATION CATTLE GUARD INSTALLATION 7.1. DONE BY OTHERS. DONE BY OTHERS. 8. DELIVERY OF GATES AND CATTLE GUARDS DELIVERY OF GATES AND CATTLE GUARDS 8.1. AS SHOWN AND BID ON THE SCHEDULE OF ITEMS. AS SHOWN AND BID ON THE SCHEDULE OF ITEMS. 8.2. MONDAY THROUGH FRIDAY ONLY, EXCLUDING MONDAY THROUGH FRIDAY ONLY, EXCLUDING FEDERAL HOLIDAYS. 8.3. PROVIDE AT LEAST 48 HOURS (TWO BUSINESS PROVIDE AT LEAST 48 HOURS (TWO BUSINESS DAYS) ADVANCE NOTICE PRIOR TO DELIVERY.
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/9 /20
:2
1 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\C
HR
IS
W
MI
LL
ER
\O
NE
DR
IV
E
- U
SD
A\
DO
CU
ME
NT
S\
CA
D
DE
TA
IL
S\
GA
TE
SA
ND
CA
TT
LE
GU
AR
DS
_2
5.D W
G;
R3
SOUTHWESTERN REGION
GATES AND CATTLE
GUARDS IDIQ
APACHE-SITGREAVES
NATIONAL FORESTS
FOREST-WIDE
16-FOOT GATE
FABRICATON
04/15/2020
R.POLANCO
R.POLANCO
C.MILLER
A-01
009003
NO SCALE
PLATE EXTENSION;
DETAIL 2C
GATE EXTENSION,
DETAIL 2B
MAIN GATE FRAME,
DETAIL 1A
HINGE POST,
DETAIL 2A
2"
6'-61 2"
16"TYP.
16"
2 1
16"TYP. 3
4'-2" 2'-6"
16'-0"
7'-111 2" 7'-41
2" 8"
3'-0"
2"
2' 4'1'0
SCALE
1" = 2'
SHEET LEGEND
1 SCH. 80, NPS 3"
2 2" WIDE BY 3" HIGH
RECTANGULAR STEEL
TUBING, 18" THICK
3 1
2" STEEL PLATE
DETAIL 1A ELEVATION VIEW
4" NPT THREAD
GREASE FITTING,
TOP AND BOTTOM (TYP.)
2'-91 2"
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
E
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/9 /20
:2
1 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\C
HR
IS
W
MI
LL
ER
\O
NE
DR
IV
E
- U
SD
A\
DO
CU
ME
NT
S\
CA
D
DE
TA
IL
S\
GA
TE
SA
ND
CA
TT
LE
GU
AR
DS
_2
5.D W
G;
R3
SOUTHWESTERN REGION
GATES AND CATTLE
GUARDS IDIQ
APACHE-SITGREAVES
NATIONAL FORESTS
FOREST-WIDE
HINGE POST AND
GATE ATTACHMENTS
04/15/2020
R.POLANCO
R.POLANCO
C.MILLER
A-02
009004
4'-7"
2"
2"
2"
TYP.
4"
SEAL
4"
3'-31 2"
1"
TYP.
16"
16"
8'-0"
SCH. 80, 8" NPS
HINGE POST
SCH. 40, 2 12" NPS
STEEL HINGE (TYP.)
TACK WELD
TOP HINGE ONLY;
(FIELD ADJUSTED)
16" STEEL (TYP.)
4" STEEL POST
CAP
DETAIL 2A ELEVATION VIEW
PLAN VIEW
HINGE POST
6"
2"
1"
3"
2"
R = 45 16"
TYP.
4"
4"
SCH. 40, 2 12" NPS
STEEL HINGE (TYP.)
DETAIL 2B 3-D VIEW
DETAIL 2C 3-D VIEW
DETAIL 2D 3-D VIEW
2"
2"
6'-0"
2"
4"
12"
2" X 12" SLOT3
8" STEEL PLATE
4"
4"
GATE EXTENSION
PLATE EXTENSION
GATE + PLATE EXTENSION
RECTANGULAR TUBING IS 18" THICK.
INSERT GATE EXTENSION LOOSE; DO NOT WELD.
(FIELD ADJUSTED AND WELDED)
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/9 /20
:2
1 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\C
HR
IS
W
MI
LL
ER
\O
NE
DR
IV
E
- U
SD
A\
DO
CU
ME
NT
S\
CA
D
DE
TA
IL
S\
GA
TE
SA
ND
CA
TT
LE
GU
AR
DS
_2
5.D W
G;
R3
SOUTHWESTERN REGION
GATES AND CATTLE
GUARDS IDIQ
APACHE-SITGREAVES
NATIONAL FORESTS
FOREST-WIDE
TYPE 1 AND TYPE 2
HOLDING POSTS
04/15/2020
R.POLANCO
R.POLANCO
C.MILLER
A-03
009005
8'-0"
DETAIL 3A ELEVATION VIEW
7"
4" STEEL
POST CAP
SEAL
SCH. 40, 21
2" NPS
HOLDING POST
TYPE 1 HOLDING POST
PLAN VIEW
2"
2"
2 12" X 12" SLOT
CENTERED
ON BELL
SCH. 40, 8" NPS
BELL HOUSING
DETAIL 3B ELEVATION VIEW
PLAN VIEW
TYPE 2 HOLDING POST
SCH. 80, 3" NPS
HOLDING POST
SCH. 40, 21
2" NPS
POST EXTENSION
2'-6"
12" X 6" STEEL
PLATE, 14" THICK
2'-5"
7"
SCH. 40, 8" NPS
BELL HOUSING
2"
3"
2"
3"
TYP. 3
16"
3"
2"
2 12" X 12" SLOT
CENTERED
ON BELL
SEAL
4" STEEL
POST CAP
INSTALL LOOSE;
(FIELD ADJUSTED AND
WELDED BASED ON
FINAL ELEVATION)
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/9 /20
:2
1 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\C
HR
IS
W
MI
LL
ER
\O
NE
DR
IV
E
- U
SD
A\
DO
CU
ME
NT
S\
CA
D
DE
TA
IL
S\
GA
TE
SA
ND
CA
TT
LE
GU
AR
DS
_2
5.D W
G;
R3
SOUTHWESTERN REGION
GATES AND CATTLE
GUARDS IDIQ
APACHE-SITGREAVES
NATIONAL FORESTS
FOREST-WIDE
GATE ACCESSORIES
04/15/2020
R.POLANCO
R.POLANCO
C.MILLER
A-04
009006
4"
1"
2" 4"
2"
2" X 12" SLOT
1" 1 2"
2"
TYP.
16"
4" STEEL
PLATE
PROVIDE 12-INCH CHAIN, 14" THICK AND WELD
CHAIN END TO TOP OF LOCK TAB; PROVIDE
LOOSE.
(LOCK TAB AND CHAIN FIELD WELDED
TO FINAL LOCATION)
TOP
BOTTOM
DETAIL 4A 3-D VIEW
LOCK TAB
DETAIL 4C 3-D VIEW
3" 13 8"
2"
2" X 5 8" SLOT
1/2"1
4" STEEL
PLATE
DOUBLE LOCK BAR
SLOTTED LOCKING TAB PLATE
2 12" X 12" SLOT
6"
5 3 16"
R = 4 5 16" 2 11
16"
1 3 16"
4" STEEL
PLATE
PROVIDE LOOSE
(FIELD WELDED TO
FINAL LOCATION ON
HINGE POST)
DETAIL 4B 3-D VIEW
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
C LROAD
CL
ROAD
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/9 /20
:2
1 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\C
HR
IS
W
MI
LL
ER
\O
NE
DR
IV
E
- U
SD
A\
DO
CU
ME
NT
S\
CA
D
DE
TA
IL
S\
GA
TE
SA
ND
CA
TT
LE
GU
AR
DS
_2
5.D W
G;
R3
SOUTHWESTERN REGION
GATES AND CATTLE
GUARDS IDIQ
APACHE-SITGREAVES
NATIONAL FORESTS
FOREST-WIDE
SINGLE GATE
INSTALLATION
04/15/2020
R.POLANCO
R.POLANCO
C.MILLER
A-05
009007
4'-8"
2'-0"
SLOTTED LOCKING
TAB PLATE (FIELD
WELD TO FINAL LCOATION)
1'-0"
4'-3"
1'-0"
16'-0"
EXISTING ROAD GRADE
HINGE POST
HINGE POST FOOTING
TYPE 1 HOLDING POST
TYPE 1 POST FOOTING (TYP.)
ADJUST GATE EXTENSION
AS NEEDED (FIELD WELD TO
FINAL LOCATION)
TYPE 1 HOLDING POST
IN FOOTING; LOCATE BASED
ON FINAL SWING RADIUS
TYPE 1 HOLDING POST
IN FOOTING; LOCATE BASED
ON FINAL GATE EXTENSION
LENGTH
HINGE POST IN FOOTING
ELEVATION VIEW
PLAN VIEW
3'-71 2"
3'-91 2"
1'-0"
6"
4'-21 2"
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
C LROAD
CL
ROAD
DRAWING TITLE
DRAWN
DESIGNER
CHECKED
ARCHIVE NO.
DATE
PROJECT NO.
DWG SHEET NO.
OFSHEET
United States Department of Agriculture Forest Service
6/9 /20
:2
1 R
IC
HA
RD
RP
OL
AN
CO
C :\U
SE
RS
\C
HR
IS
W
MI
LL
ER
\O
NE
DR
IV
E
- U
SD
A\
DO
CU
ME
NT
S\
CA
D
DE
TA
IL
S\
GA
TE
SA
ND
CA
TT
LE
GU
AR
DS
_2
5.D W
G;
R3
SOUTHWESTERN REGION
GATES AND CATTLE
GUARDS IDIQ
APACHE-SITGREAVES
NATIONAL FORESTS
FOREST-WIDE
DOUBLE GATE
INSTALLATION
04/15/2020
R.POLANCO
R.POLANCO
C.MILLER
A-06
009008
4'-8"
2'-0"
SLOTTED LOCKING
TAB PLATE (FIELD
WELD TO FINAL
LCOATION) (TYP.)
1'-0"
32'-0"
EXISTING ROAD GRADE
HINGE POST
(TYP.)
HINGE POST
FOOTING (TYP.)
ADJUST GATE EXTENSION
AS NEEDED (FIELD WELD TO
FINAL LOCATION) (TYP.)
TYPE 1 HOLDING POST
IN FOOTING; LOCATE BASED
ON FINAL GATE EXTENSION
LENGTH (TYP.)
HINGE POST
IN FOOTING (TYP.)
TYPE 2 HOLDING POST
(FIELD WELD LOOSE
POST TO FINAL ELEVATION)
ELEVATION VIEW
PLAN VIEW
3'-71 2"
1'-0"
4'-41 2"
AutoCAD SHX Text
PROJECT NAME
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
| Sheets and Views |
| GatesAndCattleguards_20200415-G-01 |
| GatesAndCattleguards_20200415-G-02 |