SITE PLAN
TH3
MAH
DR
AS SHOWN
SCALES ACCORDINGLY.
THIS SHEET, ADJUST
IF NOT ONE INCH ON
0" 1"
ORIGINAL DRAWING.
BAR IS ONE INCH ON
VERIFY SCALES
APPRBYNO. DATE REVISIONS
SHEET NO.
DRAWING NO.
30503.013.01
DATE:
MAY 2021
INDIAN HEALTH SERVICES
SCATTERED SITES PROJECT - MURPHY SITE
WALDPORT, OREGON
BEND OFFICE
1020 SW EMKAY DRIVE, #100
BEND, OR 97702
541.322.8962
541.382.2423 FAX
PROJECT NO: SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
20 0 20 40
SCALE OF FEET
SCALE: 1"=20'
WELL EL. 286.42'
ESTIMATED SEPTIC AND WATER
LINE PER OWNER. CONTRACTOR
TO POTHOLE LINES.
ESTIMATED WATER LINE,
PER OWNER
HOUSE
FLOOR
EST. EL.
297.54'
LEGEND
DOWNHILL SLOPE
APPROXIMATE
GRAVEL
DRIVEWAY
GRASS LAWN
WATER AND GAS LINE
INTO STRUCTURE
SITE INFORMATION
OWNER: MURPHY, ROBIN AND WILLIAM
ADDRESS: 4244 SOUTH BEAVER CREEK ROAD, WALDPORT
PROPERTY ID: R34766
SURVEY INFORMATION
1. BASE MAP DEVELOPED FROM AN ELECTRONIC IMAGE
OBTAINED FROM GOOGLE EARTH. AERIAL IMAGE WAS
OBTAINED AUGUST 5, 2020.
2. SITE BOUNDARIES ARE APPROXIMATE.
3. DATA COLLECTION WAS PERFORMED WITH A TRIMBLE
GEO7X CENTIMETER EDITION WITH MAST AND ANTENNA.
4. DATUM INFORMATION:
US STATE PLANE 1983
ZONE 3601
NAD 1983 (CONUS) DATUM
GEOID 12A (CONUS)
5. DATA COLLECTION PERFORMED BY CENTURY WEST
ENGINEERING JULY 28, 2020.
SEPTIC TANK, SIZE KNOWN
SEPTIC CLEANOUT
TELEPHONE POLE AND BOX. PER
OWNER, NEW TRANSITION FROM
OVERHEAD TO UNDERGROUND POWER.
TELEPHONE POLE AND METER BOX. PER
OWNER, TO BE DEMOLISHED BY POWER
COMPANY AND RAN UNDERGROUND.
RETAINING WALL
APPROXIMATE
GRAVEL
DRIVEWAY
APPROXIMATE
SHOP
ESTIMATED
GARAGE
SEPTIC DRAIN
FIELD
EXISTING WATER FILTRATION BUILDING
ABANDON EXISTING WATERLINE IN PLACE
REVISION 1 NOTES:
-The Homeowner has provided the pumphouse with electrical power supply -The water line from the well to the pumphouse shall be replaced along the same alignment -Electrical supply from the pumphouse to the well shall be provided. The pump controls do not need to be rerouted from the old pumphouse.
-A new submersible pump, drop pipe, and submersible cable are to be provided in the existing well
(1.20.2022)
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text
CENTURY
AutoCAD SHX Text
WEST
AutoCAD SHX Text E N G I N E E R I N G
AutoCAD SHX Text N
AutoCAD SHX Text 8' x 8' PUMPHOUSE SEE SCHEMATIC, SHEET 2
AutoCAD SHX Text
CONNECT TO EXISTING WATERLINE. ADAPTERS AND FITTINGS AS NEEDED
AutoCAD SHX Text
1" HDPE PRESSURE PIPE
AutoCAD SHX Text
1" HDPE PRESSURE PIPE
AutoCAD SHX Text
CONNECT TO EXISTING WATERLINE AT STRUCTURE. ADAPTERS AND FITTINGS AS NEEDED
AutoCAD SHX Text
EXTEND UNDERGROUND ELECTRICAL CONNECTION TO PUMP HOUSE
AutoCAD SHX Text
REROUTE WELL PUMP CONTROLS TO NEW PUMPHOUSE
AutoCAD SHX Text
COARSE GRAVEL RIPRAP AT FILTER BACKWASH DISCHARGE
AutoCAD SHX Text
5/8" FILTER BACKWASH TUBING INSIDE 1" HDPE PIPE AS CONDUIT
Z P r o j e c t s I n d i a n
H e a l t h
S e r v i c e S c a t t e r e d
S i t e s M u r p h y
S i t e
C
A D
M
U R
P H
Y d w g
SCHEMATIC DETAIL
PUMP HOUSE
TH3
MBB
DR
N.T.S.
SCALES ACCORDINGLY.
THIS SHEET, ADJUST
IF NOT ONE INCH ON
0" 1"
ORIGINAL DRAWING.
BAR IS ONE INCH ON
VERIFY SCALES
APPRBYNO. DATE REVISIONS
SHEET NO.
DRAWING NO.
30503.013.01
DATE:
MAY 2021
INDIAN HEALTH SERVICES
SCATTERED SITES PROJECT - MURPHY SITE
WALDPORT, OREGON
BEND OFFICE
1020 SW EMKAY DRIVE, #100
BEND, OR 97702
541.322.8962
541.382.2423 FAX
PROJECT NO: SCALE:
CHECKED BY:
DRAWN BY:
DESIGNED BY:
1" HDPE PRESSURE PIPE FROM WELL
80 GALLON PRESSURE TANK
PH NEUTRALIZING FILTER
WITH AUTO CONTROL VALVE
IRON/SULFUR FILTER WITH
AUTO CONTROL VALVE
CARTRIDGE FILTER
3/8" O.D. CHEMICAL FEED
TUBING
POSITIVE
DISPLACEMENT
METERING PUMP
10 GALLON
POTASSIUM
PERMANGANATE
SOLTION TANK
1" HDPE PRESSURE PIPE TO HOUSE
NOTE:
1. ALL PIPING INSIDE PUMPHOUSE SHALL BE 1" SCHEDULE 40 PVC UNLESS OTHERWISE NOTED.
2. CONTRACTOR SHALL PROVIDE ALL PIPE, FITTINGS, AND ADAPTERS NEEDED FOR A COMPLETE
FUNCTIONING INSTALLATION.
13" DIA. 10" DIA.
54" NOM. 54" NOM.
CHEMICAL INJECTION TEE
1" PVC TRUE UNION BALL VALVE (TYP.)
PRESSURE
CONTROL
SWITCH
HOSE BIB
5/8" FILTER BACKWASH TUBING
INSIDE 1" HDPE PIPE AS CONDUIT
FILTER BACKWASH
DISCHARGE TO DAYLIGHT
5/8" FILTER BACKWASH TUBING
AutoCAD SHX Text
CENTURY
AutoCAD SHX Text
WEST
AutoCAD SHX Text E N G I N E E R I N G