Attachment 4 IDS_Drawings-COS_Updates.pdf
PDF 266 KB Posted
- Attached to
- IDS System for SCIF Federal contract opportunity
- Solicitation number
- W50S9B23Q0001
- Issued by
- Department of the Army National Guard
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment 1 PWS and PRS 185 COS MILCON IDS v2 CAO 13 May 2022.docx | DOCX document | |
| IDS Questions and Answers.docx | DOCX document | |
| W50S9B23Q0001 Request for Quote VaANG IDSC Revised Due Date 2.docx | DOCX document | |
| W50S9B22Q0010 Request for Quote VaANG IDSC Revised Due Date.docx | DOCX document | |
| W50S9B22Q0010 Request for Quote VaANG IDSC.docx | DOCX document | |
| Attachment 2 Information Sheet IDSC.docx | DOCX document | |
| Attachment 1 PWS and PRS 185 COS MILCON IDS v2 CAO 13 May 2022.docx | DOCX document | |
| Attachment 3 JA Brand Name.pdf | ||
| W50S9B23Q0001 Request for Quote VaANG IDSC.docx | DOCX document |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ABBREVIATIONS
ACCESS CONTROL SYSTEM (RACEWAY INFRASTRUCTURE ONLY)
CCTV SYSTEM (RACEWAY INFRASTRUCTURE ONLY)
INTRUSION DETECTION SYSTEM (RACEWAY INFRASTRUCTURE ONLY)
GENERAL ELECTRONIC SECURITY SYSTEM NOTES LEGEND & ABBREVIATIONS
ACS
IDS
M
EH
K
DC
RTE
CCTV
CR
ML
J
GENERAL SPECIAL SYSTEMS
THE GENERAL CONTRACTOR SHALL PROVIDE A COMPLETION SCHEDULE, BROKEN DOWN BY VARIOUS CONSTRUCTION PHASES. THE CONTRACTOR SHALL COORDINATE TURNOVER WITH VENDORS, AND SHALL TURNOVER AREAS WITH ADEQUATE TIME FOR VENDOR FINISH WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY EXTRA VENDOR
COST RESULTING FROM INCORRECT SYSTEMS ROUGH-IN.
THE GENERAL CONTRACTOR SHALL PROVIDE IN-WALL REINFORCEMENT AS NECESSARY FOR ALL SYSTEMS CABINETS, SHELVES, BRACKETS, FURNITURE MOUNTS, ETC.. AND SHALL MOUNT CABINETS, SHELVES, BRACKETS, AND FURNITURE
MOUNTS IN ACCORDANCE WITH DRAWINGS, VENDOR SUBMITTALS, AND ALL APPLICABLE CODES.
THE CONTRACTOR SHALL COORDINATE AND PROVIDE ALL REQUIRED RACEWAY SYSTEMS FOR ALL ELECTRONIC SECURITY SYSTEMS INCLUDING CONDUIT WITH PULL STRING, JUNCTION BOXES, GROUNDING, BACKBOARDS, POWER CONNECTIONS, ETC. THE CONTRACTOR SHALL COORDINATE ALL ROUGH-IN, BOX SIZES AND CONFIGURATIONS, CONDUIT SIZES AND ROUTING WITH THE OWNER'S SECURITY VENDOR PRIOR TO INSTALLATION OF THE RACEWAY SYSTEM.
REQ'D REQUIRED
OSP OUTSIDE PLANT
NATIONAL ELECTRICAL CODENEC
GROUNDGND
EXIST EXISTING
EXISTING TO REMAINETR
CONDUIT C
UNLESS OTHERWISE NOTEDUON
AREA OF REFUGE ASSISTANCEARA
ABOVE FINISHED GRADEAFG
ABOVE FINISHED FLOORAFF
FMCP FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
BELOW FINISHED GRADEBFG
BUILDING ENTRANCE PROTECTORBEP
ENTRANCE FACILITYEF
MULTIMODE FIBER OPTICMMFO
MAIN DISTRIBUTION FRAMEMDF
SMFO SINGLE MODE FIBER OPTIC
PNL PANEL
TELEPHONETELE
TELECOMMUNICATIONS ROOMTR
ACCESS CONTROL SYSTEM CONTROL PANEL
INTRUSION DETECTION SYSTEM CONTROL PANEL
MOTION SENSOR, 360° PASSIVE INFRARED CEILING MOUNTED.
ELECTRIFIED HARDWARE
ARM/DISARM KEYPAD
SEE TYPICAL SECURITY
DOOR CONFIGURATION
DETAIL ON SHEET TY501
CCTV DOME CAMERA
WEATHERPROOFWP
DOOR CONTACT
REQUEST TO EXIT
INTRUSION DETECTION SYSTEMIDS
CLOSED CIRCUIT TELEVISION SYSTEM CONTROL PANEL
CARD READER
CONTROLLED ACCESS AREA (CAA) BOUNDARY
CONTROLLED ACCESS AREACAA
MAGNETIC LOCK
JUNCTION BOX
CAA BOUNDARY PENETRATION NOTE:
METALLIC CONDUIT: PROVIDE A DIELECTRIC UNION INSIDE THE CAA
BOUNDARY ADJACENT TO THE PENETRATION OR GROUND THE CONDUIT
WITHIN 6 INCH OF THE PERIMETER PENETRATION USING A NO. 4 COPPER
WIRE CONNECTED TO THE BUILDING GROUND.
METALLIC PLUMBING PIPE: PROVIDE A DIELECTRIC UNION INSIDE THE
CAA BOUNDARY ADJACENT TO THE PENETRATION. IF DIELECTRIC
UNIONS ARE NOT ALLOWED DUE TO LOCAL CODES, GROUND THE
CONDUIT WITHIN 6 INCH OF THE PERIMETER PENETRATION USING A NO.
4 COPPER WIRE CONNECTED TO THE BUILDING GROUND.
METALLIC SPRINKLER (FIRE SUPPRESSION) PIPE: PROVIDE A UL LISTED
DIELECTRIC UNION INSIDE THE CAA BOUNDARY ADJACENT TO THE
PENETRATION OR GROUND THE PIPE WITHIN 6 INCH OF THE PERIMETER
PENETRATION USING A NO. 4 COPPER WIRE CONNECTED TO THE
BUILDING GROUND.
COPPER REFRIGERANT (HVAC) LINE: GROUND THE LINE WITHIN 6 INCH OF
THE PERIMETER PENETRATION USING A NO. 4 COPPER WIRE
CONNECTED TO THE BUILDING GROUND. MAINTAIN INTEGRITY OF
REFRIGERANT LINE INSULATION.
A I
N I
G
RI
VFOHTLAE
W
N O
M M
O C
P R
O F
E
SS I ONAL ENG
I N E
E R
MARTIN H. FORD
Lic. No. 048072
08/15/2019
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
W -1
-D
-0
W S
P
B
E N
D
IX
R O
A D
S U
IT
E
V
IR
G
IN
IA
B
E A
C H
V
A
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
N O
R F
O L K
D
IS
T R
IC
T
N O
R F
O L K
V
A
DATE & TIME STAMP:
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
H E
L M
S A
V E
J B
L E
C Y
B E
R O
P S
F A
C
IL
IT
Y
RTA SUBMITTAL8/14/2019 1:56:01 PM
TY001
L E
G E
N D
N
O T
E S
A N
D A
B B
R E
V
IA
T
IO
N S
C R
W
C A
R
M H
F
/1
/2
M U
H J
C M
T
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R F
R
C R
C R
C R
C R
DC DCDC DC
DC
D C
K
CR
107 108
114 120
128 122
115103
M
M
M
M
M
DC
D C
D C
M
TRANSFORMER
GENERATOR
(CLIN 0004)
DORMER
ABOVE
DORMER
ABOVE
CCC-1
MC
1 2 3 4 5
C
B
A
0.1A
1.4 1.6
M2 M3 M3.2M1
MB
MA
ACS IDS CCTV
D C
EH
RTE
E H
E H
BIDDERS NOTE - CLIN 0003:
THE ELECTRONIC SECURITY SYSTEM (ACS, IDS & CCTV) EQUIPMENT, CABLING,
INSTALLATION, TERMINATION AND TESTING WILL BE PROVIDED BY THE OWNERS
SECURITY VENDOR UNDER CLIN 0003.
1 COORDINATE FINAL LOCATION WITH OWNER / END-USER PRIOR TO INSTALLATION.
A I
N I
G
RI
VFOHTLAE
W
N O
M M
O C
P R
O F
E
SS I ONAL ENG
I N E
E R8' 16' 24'
SCALE: 1/8" = 1' - 0"
0'
MARTIN H. FORD
Lic. No. 048072
08/15/2019
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
W -1
-D
-0
W S
P
B
E N
D
IX
R O
A D
S U
IT
E
V
IR
G
IN
IA
B
E A
C H
V
A
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
N O
R F
O L K
D
IS
T R
IC
T
N O
R F
O L K
V
A
DATE & TIME STAMP:
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
H E
L M
S A
V E
J B
L E
C Y
B E
R O
P S
F A
C
IL
IT
Y
RTA SUBMITTAL8/14/2019 1:56:04 PM
TY101
F L O
O R
P L A
N
S E
C U
R
IT
Y
C R
W
C A
R
M H
F
/1
/2
M U
H J
C M
T
ROOM SCHEDULE
100 VEST
101 CORRIDOR
102 CSS
103 COMMANDER
104 FIRST SERGEANT
105 SUPER
106 BREAK
107 COMM
108 JAN
109 WOMEN
110 MEN
111 MANTRAP
112 OPEN OFFICE
113 OSS
114 STDS AND EVAL
115 OFFICE
116 OFFICE
117 OFFICE
118 CONFERENCE
119 CORRIDOR
120 TRAINING
121 SERVER
122 CYBER SYSTEM
MAINTENANCE
123 OPS FLOOR
124 MEETING
125 MEETING
126 OFFICE
127 MECH
128 ELEC
129 MECHANICAL YARD
SCALE: 1/8" = 1'-0"
FLOOR PLAN
B1
N
NOTES THIS SHEET
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
1187965353N Stamp
1187965353N Callout Add Card Reader on internal side only
1187965353N Stamp
1187965353N Callout Add Card Reader on internal side only
1187965353N Stamp
1187965353N Callout Add Card Readers for Ops Floor access
1187965353N Stamp
1187965353N Stamp
1187965353N Stamp
1187965353N Callout Add Card Readers for Server Room access
1187965353N Text Box Addition of 6 Card Readers to support access control to these locations. Exterior Doors in room 121 and 123 should only allow opening from inside the building for Emergency egress or card reader override. Door Hardware should be installed by the Construction Contractor as specified to support the IDS Contractor installation.
NO SCALE
NO SCALE
FIRST FLOOR
RAISED ACCESS FLOOR
NO SCALE NO SCALE
FIRST FLOOR
RAISED ACCESS FLOOR
FIRST FLOOR
RAISED ACCESS FLOOR
TYPICAL SECURITY DOOR CONFIGURATION
ACCESS CONTROL ONE-LINE DIAGRAM INTRUSION DETECTION ONE-LINE DIAGRAM CCTV ONE-LINE DIAGRAM
53 4 3 4
DC
RTE
JJ
EH
CR
DC DC
DC DC
DC DC
DC
M M 123
M 121
M M 101
K
CR 100
M 118
CR CR CR CR 111
DC
DC DC 123
113 113
SECURE SIDE NON-SECURE SIDE SECURE SIDE NON-SECURE SIDE
TYPICAL DOUBLE DOOR TYPICAL SINGLE DOOR
DOOR FRAME TO BE PRE-DRILLED FOR DOOR CONTACTS AND DOOR
ELECTRIFIED HARDWARE. COORDINATE INSTALLATION WITH DOOR
HARDWARE PROVIDER.
ELECTRICAL CONTRACTOR TO PROVIDE PATHWAYS AND PULLSTRINGS
FOR OWNERS SECURITY VENDOR FURNISHED ACCESS CONTROL SYSTEM.
COORDINATE DOOR HARDWARE WITH ARCHITECTURAL DOOR SCHEDULE.
ALL DOOR HARDWARE (LOCKS, HINGES, EXIT DEVICES) TO BE PROVIDED
BY DOOR HARDWARE PROVIDER.
PROVIDE STAINLESS STEEL COVERPLATES FOR BOXES.
8"x8"x4" HINGED
COVER ELECTRICAL
BOX, MOUNT ABOVE
ACCESSIBLE CEILING
3/4"C MINIMUM 3/4"C MINIMUM
REQUEST TO
EXIT DEVICE
MAGNETIC DOOR
CONTACT SWITCH
(DOUBLE POLE,
DOUBLE THROW
RECESSED TYPE)
REPRESENTATIVE OF ELECTRIC DOOR
STRIKE. CONSULT DOOR HARDWARE
SCHEDULE FOR ACTUAL HARDWARE.
8"x8"x4" HINGED
COVER ELECTRICAL
BOX, MOUNT ABOVE
ACCESSIBLE CEILING
NOTES:
BOX FOR
CARD
READER
FOR HALLWAY
DOORS, MOUNT
CARD READER
OR PUSHBUTTON
ON SIDEWALL AT
LEAST 48" BACK
FROM DOOR.
8"
METAL
PANEL
SECURITY PANEL
ACS/IDS/CCTV
120VAC
CORRIDOR
SERVER ROOM
OPS FLOOR
MAIN ENTRANCE
MECHANICAL ROOM
SERVER ROOM
MAN TRAP
3/4"C WITH PULL
STRING (TYP)
MAIN ENTRANCE
CONFERENCE ROOM
MAN TRAP
OPS FLOOR
INTRUSION
DETECTION SYSTEM
CCTV SYSTEM
CORRIDOR
MAIN ENTRANCE
BUILDING SW CORNER
BUILDING SE CORNER
BUILDING NE CORNER
BUILDING NW CORNER
MANTRAP
3/4"C WITH PULL
STRING (TYP)
3/4"C WITH PULL
STRING (TYP)
120VAC 120VAC
BIDDERS NOTE - CLIN 0003:
THE ELECTRONIC SECURITY SYSTEM (ACS, IDS & CCTV) EQUIPMENT, CABLING,
INSTALLATION, TERMINATION AND TESTING WILL BE PROVIDED BY THE OWNERS
SECURITY VENDOR UNDER CLIN 0003.
A I
N I
G
RI
VFOHTLAE
W
N O
M M
O C
P R
O F
E
SS I ONAL ENG
I N E
E R
MARTIN H. FORD
Lic. No. 048072
08/15/2019
US Army Corps of Engineers ®
SHEET ID
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
W -1
-D
-0
W S
P
B
E N
D
IX
R O
A D
S U
IT
E
V
IR
G
IN
IA
B
E A
C H
V
A
UNCLASSIFIED\\FOR OFFICIAL USE ONLY
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
N O
R F
O L K
D
IS
T R
IC
T
N O
R F
O L K
V
A
DATE & TIME STAMP:
G
F
E
D
C
B
A
1 2 3 4 5 6 7 8 9 10
H E
L M
S A
V E
J B
L E
C Y
B E
R O
P S
F A
C
IL
IT
Y
RTA SUBMITTAL8/14/2019 1:56:04 PM
TY501
S E
C U
R
IT
Y D
E T
A
IL
A N
D O
N E
-L
IN
E D
IA
G
R A
M S
C R
W
C A
R
M H
F
/1
/2
M U
H J
C M
T
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
File details come from the government source that posted it. Updated .