Attachment (4) - Drawing.pdf
PDF 194 KB Posted
- Attached to
- TUNGSTEN SHIELDING Federal contract opportunity
- Solicitation number
- N4215826QE031
About this file
This is an engineering drawing and technical specification for a CDM Outsert Shielding component prepared by Norfolk Naval Shipyard, Code 2370 Reactor Servicing. The document provides detailed dimensional specifications and fabrication requirements for a magnetic tungsten-impregnated rubber shielding piece designed to fit around standard 8-inch Schedule 40 pipe.
The outsert shield must be manufactured from magnetic tungsten-impregnated rubber shielding with a minimum density of 7 g/cc and a Tenth-Value Layer (TVL) of 2.00 inches or greater, per APL specification. Each individual piece must weigh less than 40 pounds, and six pieces are required per position to fit together around the pipe with no gaps present. The magnetic layer must be applied to the interior surface at minimum, with possible application to the 30-degree side cuts if feasible. Each piece must be labeled externally with "RF-7445" and its weight in a suitable color other than yellow or magenta. The drawing shows detailed isometric and front views with specific dimensions including radii (R4.31, R5.50, R5.75), angles (30 and 60 degrees), and a total length of 15.00 inches. The document was originally issued on July 7, 2025, by engineer A. Davidson and approved by Samuel Bower (SOF) on July 8, 2025.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Attachment (3) - Certificate of Compliance.pdf | ||
| Attachment (2) - Fabrication Details.pdf | ||
| Attachment (5) - Technical Capability Statement.pdf | ||
| Attachment (1) - US PATENT.pdf | ||
| RFQ N4215826QE031.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISO VIEW
TOP VIEW
FRONT VIEW
VIEW A-A
(ENLARGED)
A A
A
B
C
D
E
F
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
F
E
D
C
B
A
UNLESS OTHERWISE
SPECIFIED, ALL
DIMENSIONS ARE IN
INCHES, AND TOLERANCES
ARE AS FOLLOWS:
DECIMALS
X = +/- 0.250
X.X = +/- 0.062
X.XX = +/- 0.010
X.XXX = +/- 0.005
FRACTIONS = +/- 1/8
ANGLES = +/- 1 DEG.
NORFOLK NAVAL SHIPYARD
CODE 2370 REACTOR SERVICING
TITLE
SIZE SCALE DWG NO. REV
CLASSIFICATION
DRAWN
CHECKED
CONCURRENCE
CONCURRENCE
CONCURRENCE
APPROVED
CDM OUTSERT SHIELDING
2370.2-7445A OI
SHEET 1 OF 1 UNCLASSIFIED
NTS
DATE
DATE
DATE
DATE
DATE
DATE
ALYX DAVIDSON 08JUL2025
SAMUEL BOWER (SOF) 08JUL2025
PARTS LIST
PC. #
QTY.
DESCRIPTION SPECIFICATION
1 1 Outsert Shield
-Magnetic Tungeston impregnated rubber shielding with a minimum density of 7 g/cc and TVL greater than or equal to 2.00", APL
FABRICATION NOTES
# NOTE
1 CALCULATED WEIGHT FOR EACH PIECE IS <40 LBS.
QTY 6 MUST FIT TOGETHER AROUND A STANDARD 8" SCHEDULE 40 PIPE
WITH NO GAPS PRESENT.
LABEL "RF-7445" ALONG WITH THE WEIGHT ON THE EXTERIOR OF THE
PIECE. CHARACTER AND SIZE TO SUIT. (THIS SHOULD BE DONE BY THE
VENDOR IN A SUITABLE COLOR OTHER THAN YELLOW OR MAGENTA).
QTY 6 PC 1'S ARE REQUIRED PER POSITION.
MAGNETIC LAYER TO BE ON THE INTERIOR SURFACE AT A MINIMUM.
MAGNETIC LAYER MAY BE APPLIED TO THE 30-DEGREE SIDE CUTS IF
POSSIBLE.
SHEET 1 SHEET 2 SHEET 3
OI
SHEET 4 SHEET 5 SHEET 6
REVISION HISTORY
REV ZONE DESCRIPTION DATE
Eng.
OI ALL
Original Issue 07/07/25
A. Davidson
R4.31
5.50
R
5.75
30°
10°
60°
30°
70°
MAGNETIC LAYER 15.00
Attachment (2) Document No. 5303ZN01 david.m.love Highlight