Wednesday, March 16, 2022

Hawaii Analytical Laboratory

ANALYTICAL REPORT

NIHON MECCS CO., LTD.

4-16-7-103 MINAMI-TOBARU

Lab Job No: 202202526

Your Project: ACM Sampling for Basketball - Tennis Courts and Playgrounds, 2/25/22

OKINAWA CITY, OKINAWA Okinawa Japan

Date Submitted: 3/15/2022

Facsimile:

Phone Number: (098)932-6250

Email: -

Sample ID / Description Asbestos Present?

%v/vSample No. Date Analyzed

MatrixOther Fibrous

Bulk Asbestos Determination

Type %v/v

A-01 Tennis Court Coating Material, OG71056 O'Donnell, Red, Gray

NONE

DETECTED

202218908 3/15/2022

Red / gray coating material

Cellulose (undulose)

Tar + calcite + quartz

Comments

Layer

A-02 Tennis Court Coating

Red, Gray

202218909 3/15/2022

A-03 Tennis Court Coating

Green, Gray

202218910 3/15/2022

A-04 Tennis Court Coating

Green, Gray

202218911 3/15/2022

A-05 Tennis Net Post Foundation, OG71056 O'Donnell, Gray

202218912 3/15/2022

Gray cementitious material

None detected Cementitious

A-06 Caulking Material, OG71056 O'Donnell, Black

202218913 3/15/2022

Black caulk

Other

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 1 of 23615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

Lab Job No: 202202526

A-07 Fence Post Foundation, 202218914 3/15/2022

A-08 Light Post Foundation, 202218915 3/15/2022

A-09 Neo Seal, Elec Control Panel

Chrysotile 3Yes202218916 3/15/2022

Gray neo seal

Calcite + binder

Eva Skogsberg

Laboratory Manager

General Comments The bulk sample[s] analysis subject of this analytical report were conducted in general accordance with the procedures outlined in the United States Environmental Protection Agency’s “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA-600/M4-82-020, Dec. 1982) and / or “Method for Determination of Asbestos in bulk Building Materials” (EPA-600/R-93-116, July 1993). The analysis of each bulk sample relates only to the material examined, and may or may not represent the overall composition of its original source. Floor tile and other resinously bound materials, when analyzed by the EPA methods referenced above may yield false negative results because of limitations in separating closely bound fibers and in detecting fibers of small length and diameter. Alternative methods of identification, including Transmission Electron Microscopy (TEM) may or may not be applicable. We utilize calibrated visual area estimation on a routine basis and do not conduct point counting unless specifically requested to do so. Estimated error for the visual determinations presented are 75% relative (1 to 2%), 50% relative (3 to 5%); 25% relative (6 to 25%) and 20% (>26% v/v). We will not separate layers which in our opinion are not readily discernable. This report is not to be duplicated except in full without the expressed written permission of Hawaii Analytical Laboratory. This report must not be used by the client to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Governement. Unless otherwise indicated, the sample condition at the time of receipt was acceptable.

Results and Symbols Definitions > This testing result is greater than the numerical value listed.

< This testing result is less than the numerical value listed.

None Detected = asbestos was not observed in the sample. If trace amount of asbestos was detected below our quantifiable limits of 1.0%, <1% (trace) would be indicated and the asbestos type listed. Point counting, where applicable, are recommended to improve accuracy.

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 2 of 23615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

16 March 2022 issued amended report to replace original report dated 16 March 2022.

Lab Job No: 202202527

A-01 Textured Concrete Wall, Pavilion OG71086 O'Donnell, Ivory, Gray

202218917 3/15/2022

Gray concrete

None detected

Cementitious

202218917 3/15/2022

Ivory textured paint

Paint + calcite

A-02 Textured Concrete Wall, Ivory, Beige, Gray

202218918 3/15/2022

202218918 3/15/2022

Ivory / beige textured paint

A-03 Textured Concrete Wall, 202218919 3/15/2022

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 1 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

16 March 2022 issued amended report to replace original report dated 16 March 2022.

202218919 3/15/2022

A-04 Concrete Floor, Pavilion OG71086 O'Donnell, Gray

202218920 3/15/2022

A-05 Concrete Floor, Pavilion

202218921 3/15/2022

A-06 Concrete Floor, Pavilion

202218922 3/15/2022

A-07 Roof Waterproofing System, Pavilion OG71086 O'Donnell, Gray

202218923 3/15/2022

Gray roof waterproofing

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 2 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

Jennifer Hsu Liao

The bulk sample[s] analysis subject of this analytical report were conducted in general accordance with the procedures outlined in the United States Environmental Protection Agency’s “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA-600/M4-82- 020, Dec. 1982) and / or “Method for Determination of Asbestos in bulk Building Materials” (EPA-600/R-93-116, July 1993). The analysis of each bulk sample relates only to the material examined, and may or may not represent the overall composition of its original source. Floor tile and other resinously bound materials, when analyzed by the EPA methods referenced above may yield false negative results because of limitations in separating closely bound fibers and in detecting fibers of small length and diameter. Alternative methods of identification, including Transmission Electron Microscopy (TEM) may or may not be applicable. We utilize calibrated visual area estimation on a routine basis and do not conduct point counting unless specifically requested to do so. Estimated error for the visual determinations presented are 75% relative (1 to 2%), 50% relative (3 to 5%); 25% relative (6 to 25%) and 20% (>26% v/v). We will not separate layers which in our opinion are not readily discernable. This report is not to be duplicated except in full without the expressed written permission of Hawaii Analytical Laboratory. This report must not be used by the client to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Governement. Unless otherwise indicated, the sample condition at the time of receipt was acceptable.

< This testing result is less than the numerical value listed.

None Detected = asbestos was not observed in the sample. If trace amount of asbestos was detected below our quantifiable limits of 1.0%, <1% (trace) would be indicated and the asbestos type listed. Point counting, where applicable, are recommended to improve accuracy.

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 3 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

Lab Job No: 202202528

Your Sample ID / Description Asbestos

Pavilion OG72020 O'Donnell, 202218924 3/16/2022 quartz

202218924 3/16/2022

202218925 3/16/2022

202218925 3/16/2022

Ivory,beige textured paint

202218926 3/16/2022

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 1 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

202218926 3/16/2022

OG72020 O'Donnell, Gray

202218927 3/16/2022

202218928 3/16/2022

202218929 3/16/2022

Pavilion OG72020 O'Donnell, Gray

202218930 3/16/2022

A-08 Playground Flooring Tile, OG72020 O'Donnell, Blue

202218931 3/16/2022

Blue/black flooring

Other

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 2 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

The bulk sample[s] analysis subject of this analytical report were conducted in general accordance with the procedures outlined in the United States Environmental Protection Agency’s “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA-600/M4-82- 020, Dec. 1982) and / or “Method for Determination of Asbestos in bulk Building Materials” (EPA-600/R-93-116, July 1993). The analysis of each bulk sample relates only to the material examined, and may or may not represent the overall composition of its original source. Floor tile and other resinously bound materials, when analyzed by the EPA methods referenced above may yield false negative results because of limitations in separating closely bound fibers and in detecting fibers of small length and diameter. Alternative methods of identification, including Transmission Electron Microscopy (TEM) may or may not be applicable. We utilize calibrated visual area estimation on a routine basis and do not conduct point counting unless specifically requested to do so. Estimated error for the visual determinations presented are 75% relative (1 to 2%), 50% relative (3 to 5%); 25% relative (6 to 25%) and 20% (>26% v/v). We will not separate layers which in our opinion are not readily discernable. This report is not to be duplicated except in full without the expressed written permission of Hawaii Analytical Laboratory. This report must not be used by the client to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Governement. Unless otherwise indicated, the sample condition at the time of receipt was acceptable.

< This testing result is less than the numerical value listed.

None Detected = asbestos was not observed in the sample. If trace amount of asbestos was detected below our quantifiable limits of 1.0%, <1% (trace) would be indicated and the asbestos type listed. Point counting, where applicable, are recommended to improve accuracy.

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 3 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

Lab Job No: 202202529

Pavilion OG72022 O'Donnell, 202218932 3/16/2022

202218932 3/16/2022

202218933 3/16/2022

202218933 3/16/2022

202218934 3/16/2022

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 1 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

202218934 3/16/2022

OG72022 O'Donnell, Gray

202218935 3/16/2022

202218936 3/16/2022

202218937 3/16/2022

Pavilion OG72022 O'Donnell, Gray

202218938 3/16/2022

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 2 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

The bulk sample[s] analysis subject of this analytical report were conducted in general accordance with the procedures outlined in the United States Environmental Protection Agency’s “Interim Method for the Determination of Asbestos in Bulk Insulation Samples” (EPA-600/M4-82- 020, Dec. 1982) and / or “Method for Determination of Asbestos in bulk Building Materials” (EPA-600/R-93-116, July 1993). The analysis of each bulk sample relates only to the material examined, and may or may not represent the overall composition of its original source. Floor tile and other resinously bound materials, when analyzed by the EPA methods referenced above may yield false negative results because of limitations in separating closely bound fibers and in detecting fibers of small length and diameter. Alternative methods of identification, including Transmission Electron Microscopy (TEM) may or may not be applicable. We utilize calibrated visual area estimation on a routine basis and do not conduct point counting unless specifically requested to do so. Estimated error for the visual determinations presented are 75% relative (1 to 2%), 50% relative (3 to 5%); 25% relative (6 to 25%) and 20% (>26% v/v). We will not separate layers which in our opinion are not readily discernable. This report is not to be duplicated except in full without the expressed written permission of Hawaii Analytical Laboratory. This report must not be used by the client to claim product certification, approval or endorsement by NVLAP, NIST or any agency of Federal Governement. Unless otherwise indicated, the sample condition at the time of receipt was acceptable.

< This testing result is less than the numerical value listed.

None Detected = asbestos was not observed in the sample. If trace amount of asbestos was detected below our quantifiable limits of 1.0%, <1% (trace) would be indicated and the asbestos type listed. Point counting, where applicable, are recommended to improve accuracy.

Hawaii Analytical Laboratory is a NIST NVLAP accredited laboratory (NVLAP Lab Code 200655-0) and is accredited in accordance with the recognized ISO/ IEC 17025:2017. Controlled doc.: Asbestos Report, rev. 3 – 20200630

Page 3 of 33615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

Tuesday, March 15, 2022

Lab Job No: 202202519

Facsimile: (098) 932-6251

Your Project: ACM Sampling for Basketball/Tennis Courts and Playgrounds, 2/25/22

Total Lead (paint chips)

Sample No. Your Sample ID / Description Results Units Date

NIOSH Method: 7082m LEAD by FAAS

202218874 L-01 Line paint, OG71056 O'donnell, White

40 mg/kg 3/15/2022<

202218875 L-02 Elec Control Panel Paint, OG71056 O'donnell, Gray

830 mg/kg 3/15/2022

202218876 L-03 Stair Handrail Paint, OG71056 O'donnell, Ivory

47 mg/kg 3/15/2022

Hawaii Analytical Laboratory (101812) is accredited by the AIHA LAP, LLC in the EMLAP, IHLAP, and ELLAP programs for the scope of work listed on www.aihaaccreditedlabs.org, in accordance with the recognized ISO/ IEC 17025:2005. AIHA is a

NLLAP recognized accrediting body. Controlled doc.: Lead Report, rev. 3 – 20181015

3615 Harding Avenue, Ste. 308, Honolulu, HI 96816 - Telephone: (808) 735-0422 - Fax: (808) 735-0047

Lab Job No: 202202519

The sample[s] analysis subject of this analytical report were conducted in general accordance with the procedures associated with the ”analytical method" referenced above. Modifications to this methodology may have been made based upon the analyst's professional judgment and / or sample matrix effects encountered. The analysis of sample relates only to the sample analyzed, and may or may not be representative of the original source of the material submitted for our analysis. All analysts participate in interlaboratory quality control testing to continuously document profiency. This report is not to be duplicated except in full without the expressed written permission of Hawaii Analytical Laboratory. This report should not be construed as an endorsement for a product or a service by the AIHA LAP, LLC or any affiliated organizations. Sample and associated sampling / collection data is reported as provided by client. TWA values have been calculated based on information supplied by the client that the laboratory has not independently verified. Results have not been corrected for blank determinations unless noted in remarks. Unless otherwise indicated the sample condition at the time of receipt was acceptable.

< This testing result is less than the numerical value listed.

# = Analytical methods marked with an "#" are not within our AIHA LAP, LLC Scope of Accreditation.

MRL = Method Reporting Limit.

All Quality Control data are acceptable unless otherwise noted.

MRL for lead air is 5ug.

MRL for lead wipe is 10ug.

MRL for lead paint or soil is 40 mg/kg for a 0.25g sample.

Hawaii Analytical Laboratory (101812) is accredited by the AIHA LAP, LLC in the EMLAP, IHLAP, and ELLAP programs for the scope of work listed on www.aihaaccreditedlabs.org, in accordance with the recognized ISO/ IEC 17025:2005. AIHA is a

16 March 2022 issued amended report to replace original report dated 15 March 2022

Lab Job No: 202202520

Total Lead (paint chips)

Sample No. Your Sample ID / Description Results Units Date

NIOSH Method: 7082m LEAD by FAAS

202218877 L-01 Elec Box Paint, Pavilion OG72020 O'donnell, Gray

202218878 L-02 Playsets Paint, Playground OG72020 O'donnell, Brown, Yellow

Hawaii Analytical Laboratory (101812) is accredited by the AIHA LAP, LLC in the EMLAP, IHLAP, and ELLAP programs for the scope of work listed on www.aihaaccreditedlabs.org, in accordance with the recognized ISO/ IEC 17025:2005. AIHA is a

16 March 2022 issued amended report to replace original report dated 15 March 2022

Lab Job No: 202202520

All Quality Control data are acceptable unless otherwise noted.

MRL for lead air is 5ug.

MRL for lead wipe is 10ug.

MRL for lead paint or soil is 40 mg/kg for a 0.25g sample.

The sample[s] analysis subject of this analytical report were conducted in general accordance with the procedures associated with the ”analytical method" referenced above. Modifications to this methodology may have been made based upon the analyst's professional judgment and / or sample matrix effects encountered. The analysis of sample relates only to the sample analyzed, and may or may not be representative of the original source of the material submitted for our analysis. All analysts participate in interlaboratory quality control testing to continuously document profiency. This report is not to be duplicated except in full without the expressed written permission of Hawaii Analytical Laboratory. This report should not be construed as an endorsement for a product or a service by the AIHA LAP, LLC or any affiliated organizations. Sample and associated sampling / collection data is reported as provided by client. TWA values have been calculated based on information supplied by the client that the laboratory has not independently verified. Results have not been corrected for blank determinations unless noted in remarks. Unless otherwise indicated the sample condition at the time of receipt was acceptable.

< This testing result is less than the numerical value listed.

# = Analytical methods marked with an "#" are not within our AIHA LAP, LLC Scope of Accreditation.

MRL = Method Reporting Limit.

Hawaii Analytical Laboratory (101812) is accredited by the AIHA LAP, LLC in the EMLAP, IHLAP, and ELLAP programs for the scope of work listed on www.aihaaccreditedlabs.org, in accordance with the recognized ISO/ IEC 17025:2005. AIHA is a

16 March 2022 issued amended report to replace original report dated 15 March 2022

File details come from the government source that posted it. Updated .