Attachment 3 USDA Provided Equipment Information 12805B24Q0374 .pdf
PDF 13 MB Posted
- Attached to
- Wastewater Outfall Auto Samplers Installation Federal contract opportunity
- Solicitation number
- 12805B24Q0374
About this file
This document appears to be Attachment 3, which provides information about USDA-provided equipment for a solicitation related to the installation of wastewater outfall auto samplers. The associated federal contract opportunity is Solicitation Number 12805B24Q0374, issued by the Department of Agriculture's Agricultural Research Service Field Research Implementation and Information Delivery Plains Area. The solicitation is for construction work with a NAICS code of 236220 and a small business size standard of $45.0 million. Contractors are expected to inspect the site and must be registered to attend the required site visit. The delivery and installation address is the USDA ARS PA NBAF in Manhattan, Kansas.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| RFI_No1 NBAF Wastewater Outfall Samplers_12805B24Q0374.pdf | ||
| Attachment 1 Statement of Work 12805B24Q0374 .pdf | ||
| Attachment 2 Wastwater Autosamplers Locations 12805B24Q0374 .pdf | ||
| Attachment 6 - Site Visit Information.docx | DOCX document | |
| Sol_12805B24Q0374.pdf | ||
| Attachment 4 Davis-Bacon Act WD KS20240056 Building Date 05 April 2024 Mod 2 Riley County KS.pdf | ||
| Attachment 5 - Fillable Site Visit Visitor Application.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AS950 ALL-WEATHERREFRIGERATED
SAMPLERS
1. Cabinet IP24, low-density polyethylene with UV inhibitor
2. Refrigeration Corrosion protected with conformal components and coating;
3. Sample Cooling Top mounted compressor and fan-forced air cooled condenser
4. 11/5 HP 115 VAC: 115 °C (239 °F) thermal overload protector, 7.1 locked rotor amps
5. 230 VAC: 120 °C (248 °F) thermal overload protector, 7.6 A peak start current
6. 3-sided wraparound plate type evaporator
7. Rigid foam insulation: 3 in. sides, 5 in. top, 6 in. bottom
8. Lockable lid to prevent tampering with programming
9. Temperature Control: 4 (±0.8) °C (39 (±1.5) °F)1
10. Sample Containers SINGLE BOTTLE: 21 L (5.5 gal) polyethylene
11. Installation category, II, 2 pollution degree
12. Temperature Operating: 0 to 50 °C (32 to 122 °F);
13. Liquid Crystal Display (LCD): -10 to 70°C (-14 to 158°F)
14. Storage: -40 to 60°C (-40 to 140°F)
15. Power Requirements 115 VAC, 60 Hz, 4.2 A or 6.4 A
16. Overload Protection: 115 VAC: 7.5 A circuit breaker 230 VAC: 5.0 A circuit breaker
17. Dimensions (W x D x H) 76 x 81 x 130 cm (30 x 32 x 51 in.)
18. Weight 86 kg (190 lb)
19. Certifications CE, UL, CSA
AS950 Controller Housing PC/ABS blend, NEMA 4X, 6, IP68, corrosion and ice resistant
Graphics Display 1/4 VGA, Color; self-prompting/ menu-driven program
User Interface Membrane switch keypad with 2 multiple function soft keys
Program Languages English
Program Lock Access code protection prevents tampering
Memory Sample history: 4000 records; Data log: 325,000 records; Event log: 2000 records
Communications USB and optional RS485 (Modbus)
AUX port inputs One 0/4-20 mA input for flow pacing
Certifications CE, UL
Sampling Features Run Modes Continuous or non-continuous
Status Screen Communicates what program is running, if there are any missed samples, when the next sample will be taken, how many samples remain, number of logged channels, time of last measurement, memory available, number of active channels, if alarms were triggered, when alarms were triggered, active sensors and cabinet temperature
Alarms Configurable alarms that show on status screen and are recorded in diagnostics alarm logs. Alarms can be set for system diagnostics and logging such as program end, sample complete, missed samples and full bottle.
Channel alarms are setpoint alarms for the recorded measurements (channels), such as pH, level and power supply voltage.
Manual Sample Initiates a sample collection independent of program in progress
Sample Volume Programmable in 10-mL (0.34 oz) increments from 10 to 10,000 mL (3.38 oz to 2.6 gal)
Interval Between Samples Selectable in single increments from 1 to 9,999 flow pulses (momentary contact closure 25 ms or 5 to 12 Vdc pulse; 4-20 mA interface optional), or 1 to 9,999 minutes in one minute increments
Datalogging SAMPLE HISTORYStores up to 4000 entries for sample time stamp, bottle number and sample status (success, bottle full, rinse error, user abort, distributor error, pump fault, purge fail, sample timeout, power fail and low main battery)
EVENT LOGStores up to 2000 entries. Records Power On, Power Fail, Firmware Updated, Pump Fault, Distributor Arm Error, Low Memory Battery, Low Main Battery, User On, User Off, Program Started, Program Resumed, Program Halted, Program Completed, Grab Sample, Tube Change Required, sensor communication errors, cooling failed, heating failed, thermal error corrected
Diagnostics View event and alarm logs as well as maintenance diagnostics
Transmi1ers & Control
ELECTRO-CHEMICAL DEVICES
Measure pH, ORP, Specific Ion, Dissolved Oxygen, Turbidity, Conduc0vity or Resis0vity with
Model S80 Intelligent Sensors
Model T80 Universal Transmi)er
Specifica(ons Input Specifica(on Digital protocol, all ECD S80 sensors, Liquid, Gas, Process sensors (Op0onal analog to digital input board for mV sensors)
Input Ranges pH -1.00 – 15.00 pH ORP -1500 - +1500 mV pION 000.1 – 999.9, Auto
Ranging: ppb ↔ ppm ↔ppthousand
Dissolved Oxygen 000.1 – 999.9 Auto Ranging: ppb,ppm, % SAT, mg/L
Conduc0vity 0.055 μS – 2.00S Auto Ranging: μS, mS, S
Resis0vity 0.001 - 20.00 meg-ohms Turbidity 000.0 - 4000NTU Auto
Ranging: NTU, FNU, mg/L, ppm, % Solids
Temperature -30°C - 140°C
Accuracy pH 0.02 pH ORP ± 1 mV pION Specific for ion type Dissolved Oxygen 2% of calibrated range Conduc0vity 2% of calibrated range Resis0vity 2% of calibrated range Turbidity 4% of calibrated range Temperature ± 0.3°C
Enclosure Polycarbonate, NEMA 4X, weatherproof, ½ DIN, (L xWx D) 5.7” X 5.7” X 3.5” (14.4cm X 14.4cm X 9.0cm)
Environmental Condi(ons Ambient Temperature -20°C - 70°C Storage Temperature -30°C - 85°C Rela0ve Humidity 0 – 90% NC
Display 128 x 64 pixels (2.75” x 1.5”) LCD, Black/Grey background on loop powered instruments, Blue/White background LED backlight on 100-240 VAC and 24 VDC powered instruments Input Power Code -0 Loop powered, 24 VDC, 600 Ω maximum load (18-36VDC @ 35 mW minimum)
Code -1 24 VDC (18-36 VDC @ 250 mW minimum)
Code -2 100-240 VAC, 50/60 Hz, 4W Outputs 4-20 mA output (standard), Fault Condi0on: 3.5 mA, 22 mA or none Modbus RTU (standard) HART® (op0onal) Alarm Relays (Op0onal) Three (3) SPDT, form 1C, 250 VAC, 3 Amp resis0ve maximum relays, user configurable as Hi/Lo or Fault alarms
Shipping Size 8” x 8” x 5”(20.5 x 20.5 x 12.7 cm) Weight 1.6 lbs. (0.75 kg)
Specifica�ons subject to change without no�ce.
Represented by:
DS T80-A3117
Model T80- Transmi1er Part Number Guide Ch 1 Inputs 1 S80 Sensor, pH, ORP, pION, Conduc0vity, Resis0vity and galvanic Dissolved Oxygen, TRITON® DO82 Op0cal DO & TR86 Turbidity
Ch 2 Inputs 0 No Input for Channel 2 1 S80 Sensor, pH, ORP, pION, Conduc0vity, Resis0vity and galvanic Dissolved Oxygen, DO82 & TR86 Turbidity
Power Supply -0 Loop Powered Transmi1er (not available for DO82 or TR86 sensors) -1 24 VDC Powered Transmi1er -2 100/240 VAC, 50/60Hz, 4W powered Transmi1er
Alarm Relays 0 No Relays 1 (3) formC 250 V 3A relays
Output 0 4-20 mA output and MODBUS RTU
1 HART®
2 2 x 4-20 mA with MODBUS RTU
Moun0ng Hardware
-00 No Moun0ng Hardware -01 Universal Mount -02 Panel Mount -03 Handrail Mount -04 Sunshield Ver0cal Rail Mount -05 Sunshield Horizontal Rail 1
Model T80- 1 1 -0 0 1 -01
Electro-Chemical Devices 1500 North Kellogg Dr.
Anaheim, California, USA 92807 Phone: +1-714-695-0051
+1-800-729-1333 Fax: +1-714-695-0057 email: sales@ecdi.com web: www.ecdi.com
T80 Moun0ng Dimensions
Model T80 Universal Transmi)er Main Display screens; the Data Screen, the Millivolt Screen and the Graphical Display screen. The Data Screen displays the measurement type, the measured value with units, the % milliamp output of the 4-20 mA channel and the temperature. The mV Screen displays the measurement type, the raw millivolt signal from the sensor, the % milliamp output of the 4-20 mA channel and the temperature. The Graphical Screens display the measurement type, the measured value with units and a graphical representa0on of the % milliamp output. Three graphical styles are available; a Trend line, a Bar graph or a Gauge. The status of alarm relays, energized/de-energized is displayed on transmi1ers with relays.
MENUS
Menu naviga0on is accomplished using membrane switch bu1ons. So! keys display the func0on associated with each bu1on. Pressing any of the bu1ons twice within 2 seconds ac0vates the Model T80 so! key menus. The primary selec0ons are the Calibra0on menu, Configura0on menu, Info Screens and Simulate menu.
CALIBRATION
Model S80 sensors come precalibrated from the factory. Field calibra0ons are easily performed with the Model T80. The Calibra0on menu includes the Auto Cal func0on, a two point calibra0on, the Standardize func0on, a single point calibra0on or the Manual Calibra0on, where previously determined Offset and Slope values are entered manually into the Model T80 transmi1er.
CONFIGURATION
The Configura0on menus allow the Model T80 transmi1er’s Display and Output func0ons and the Model S80 sensor’s characteris0cs to be configured or adjusted. Display screens include the Hold func0on, Graphical Display Style, Back Light and Contrast adjustments, Labels/Tags for naming the transmi1er, Password Protec0on and a Factory Default reset. Output screens include se2ng the addresses for MODBUS or HART® outputs, se2ng the 4-20 mA Range and fault se2ngs and configuring the Alarm Relays.
INFO
The Info screens provide Transmi1er and Sensor Informa0on. The transmi1er screens display the Name, Power, Serial#, Firmware version and the output configura0on. The sensor screens display the Name, Part #, Serial # and stored Calibra0on data.
SIMULATE
The Simulate Menu allows the input and output signals to be simulated. The outputs are easily tested by entering a 4-20 mA output value or energizing and de-energizing a relay. The Ramp func0on cycles the signal across the configured 4-20 mA range, i.e. the transmi1er generates a signal from 0 pH to 14 pH and back to 0 pH ac0va0ng relays and genera0ng a 4-20 mA output. The cycle 0me and the dura0on are adjustable allowing sufficient 0me for an individual to walk to the control room to verify the output.
POWER SUPPLY and OUTPUTS The Model T80 transmi1er is available as a loop powered (single channel only), a 24 VDC or a 100/240 VAC powered transmi1er. The loop powered version is available with an op0onal HART® output. The line powered instruments have one 4-20 mA output per channel and MODBUS RTU. Available op0ons include HART®communica0on and an Alarm Relay package. The (3) relays can be configured as Alarm (set point) relays, 0mer ac0vated relays or Fault relays.
T80 Home Screens
Descrip(on The ECD Model T80 Universal Transmi)er is a single or dual channel transmi1er designed for the con0nuous measurement of pH, ORP, pION, Dissolved Oxygen, Turbidity, Conduc0vity or Resis0vity in a general purpose industrial environment. The Model T80 transmi1er digitally communicates with any ECD Model S80 Intelligent Sensor, automa0cally configuring the transmi1er’s menus and display screens to the measured parameter. The same transmi1er can be used for any of the measurements, i.e. plug an S80 Conduc0vity Sensor into a Model T80 pH transmi1er and it will automa0cally reconfigure into a conduc0vity transmi1er. There is no longer any need to inventory mul0ple instrument types, the one Model T80 transmi1er will automa0cally configure to any of the listed measurements.
SENSORS
The Model S80 Intelligent Sensors facilitate two way communica0on with the Model T80 transmi1ers. The type of sensor, iden0ty and serial number are stored in the sensor’s memory along with calibra0on registers. The Model S80 sensors are calibrated at the factory so they are ready to use when connected to a Model T80 transmi1er. The Model S80 sensors are waterproof and submersible with all internal components epoxy encapsulated inside the ¾” O.D. housing. The Model S80 sensors use the same field proven, easily replaceable electrodes as the Model S10 and S17 sensors saving 0me and money. A digital converter op0on is available for the Model T80 transmi1er to allow the use of non-digital sensors. The digital converter is only available on line powered instruments.
DISPLAY
The Model T80 Transmi1er features a large easily viewed LCD display. Loop powered instruments have Black le1ering on a Grey background, while 100- 240 VAC and 24 VDC powered instruments have Blue le1ering on a White background when the LED backlight is on. The Model T80 display is easily switched between the single and dual channel display modes. It has three
Model T80 Universal Transmi)er
Universal Transmi)er: single or dual channel, measures pH, ORP, DO, Specific Ion, Turbidity, Conduc0vity or Resis0vity Graphic LCD Display: Easy to Read Graphical and Numerical Informa0on
Simple Menu Structure: Intui0ve, Easy to navigate and Configure
Use with ECD Digital Intelligent Sensors that are factory calibrated sensors and store data 4-20 mA output with MODBUS RTU and Alarm Relays: Flexible configura0ons for all applica0ons HART® communica(on
The ECD Point Advantage
INSTRUCTION MANUAL
MODEL T80 UNIVERSAL TRANSMITTER
T80 IM Rev. S
Screen Map
CAL
(Calibration)
Auto Cal 1 (Offset) using Calibration Solution
Cal 2 (Slope) using Calibration Solution
Standardize Enter Grab Sample Determined Value
Manual Enter Offset, the PV value and associated mV
Enter Slope, mV/pH, mV/decade, mV/ppm…
Temp Enter measured Temperature
CONFIG
(Configuration)
XMTR
LCD
Set Up
Temp. Format °C or °F
Contrast Adj. 0-100%
Back Light Enter ON time
Range Lock Choose: Auto, ppb, ppm, ppT
Graph
Line Screen Duration
Gauge
Bar
Label
TAG ID Enter Name
TAG ON/OFF
POP UP ON/OFF
SENSOR Enter Name
Output
4-20 mA
(1 or 2)
Range (PV or
Temp.)
4 mA =
20 mA =
Cal (more) Trim 4.00 mA
Trim 20.00 mA
Fault (more)
3.5 mA
22 mA
NONE
RELAY
Relay 1
Alarm Set Point
Timed Period, Duration
Fault
Relay 2
Alarm Set Point
Timed Period, Duration
Fault
Relay 3
Alarm Set Point
Timed Period, Duration
Fault
HOLD Time out: None, 15 min, 30 min…
Serial
Address
Baud rate
Format
Password
Menu Off/On “ _ _ _ _ “
CAL Off/On “ _ _ _ _ “
CNFG Off/On “ _ _ _ _ “
SIM Off/On “ _ _ _ _ “
Sensor
Sensor 1 or 2
Type Choose Type: pH, Cond, ORP…..
T COMP Enter % Comp
ISO PT Enter mV value
Qty of Sensors Choose 1 sensor or 2 sensors
COMP Dissociation, Interference, Percentage, OFF
Load Default Sensor/Transmitter Yes/No
DAMP Enter Signal Dampening (# of readings to average, 0-100)
INFO
(Information)
XMTR Configuration, Serial #, Name, Outputs
Sensor Calibration logs, Serial #, Name
SIM
(Simulate)
System Sensor 1 or 2 Fixed value
Ramp
Relays
#1 ON/OFF
#2 ON/OFF
#3 ON/OFF
4-20 mA 4-20 mA Ch 1 Enter Value
4-20 mA Ch 2 Enter Value
Model T80
PREFACE
Purchasing products from Electro-Chemical Devices, Inc. provides you with the finest liquid analytical instrumentation available. If this is your first purchase from ECD, please read the entire manual before installing and commissioning your new equipment.
Manuals are accessible on the ECD website at http://www.ecdi.com/literature/manuals.html .
If there are any questions concerning this equipment, please contact your local ECD representative, or the factory directly at:
Electro-Chemical Devices, Inc.
1500 Kellogg Dr.
Anaheim, CA 92807 USA
Telephone: +1-714-695-0051
FAX: +1-714-695-0057
Website: www.ecdi.com
Email: sales@ecdi.com http://www.ecdi.com/literature/manuals.html http://www.ecdi.com/ mailto:sales@ecdi.com
SYMBOLS USED IN MANUAL
This symbol is used to designate important information, warnings and cautions. Failure to follow this information could lead to harm to the instrument or user.
No operator serviceable parts, service by authorized service personnel only.
This symbol is used to designate a WARNING “Risk of Electrical Shock”
Disconnect supply before servicing
Equipment protected throughout by double insulation.
Contents of this manual are believed to be correct at the time of printing and are subject to change without notice. ECD is not responsible for damage to the instrument, poor performance of the instrument or losses resulting from such, if the problems are caused by:
• Incorrect operation by the user.
• Use of the instrument in incorrect applications.
• Use of the instrument in an inappropriate environment or incorrect utility program (power supply).
• Repair or modification of the related instrument by anyone not authorized by ECD.
• There are no operator accessible parts. Service and maintenance to be done by authorized personnel only.
• If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.
© 2018 Electro-Chemical Devices, Inc. All rights reserved. No part of this manual may be used or reproduced in any form or by any means, or stored in a database or retrieval system without prior written permission from
Electro-Chemical Devices, Inc. Making copies of any part of this manual for any purpose other than personal use is a violation of United States copyright laws. Document printed in the United States of America.
Model T80
Read the complete manual before installing or using the equipment.
Table of Contents
TERMS AND CONDITIONS OF SALE
RETURN GOODS POLICY
UNPACKING THE INSTRUMENT
INSTRUCTION MANUAL REVISION
1.0 GENERAL DESCRIPTION
1.1 FEATURES
1.2 SPECIFICATIONS
1.2.1 Input specification
1.2.2 Input Ranges
1.2.3 Accuracy
1.2.4 Output Signals
1.2.5 Contact Relays
1.2.6 Display
1.2.7 Enclosure
1.2.8 Power
1.2.9 Environmental Conditions
1.2.10 Shipping
1.3 Model Codes
2.0 INSTALLATION
2.1 MOUNTING
2.2 WIRING
2.2.1 Wiring, power
2.2.2 Wiring, Sensor
2.2.3 Wiring, 4-20 mA Outputs
2.2.4 Wiring, Contact Relay Outputs
2.2.5 Wiring, Serial Output MODBUS RTU
3.0 OPERATION
3.1 KEYS
3.1.1 Home/Exit Key
3.1.2 Back/Hold Key
3.1.3 Selection Adjustment Keys
3.1.4 Alpha Numeric Entry
3.2 MENU STRUCTURE
3.2.1 HOLD (Output Hold)
3.2.2 CAL (Calibration Menu)
3.2.3 CONFIG (Configuration Menu)
3.2.4 INFO (Information Menu)
3.2.5 SIM (Simulation Menu)
3.2.6 Fault Screens
3.2.7 SENTINEL® Screens
3.2.8 Ammonium Hydra-DS
3.3 START UP GUIDE
3.3.1 Configure 4-20 mA output range
3.3.2 Configure 4-20 mA Fault Condition and Cal
3.3.3 Configure Alarm Relays (Relays Optional)
3.3.4 Exit Menus and Return to Main Display
3.3.5 Sensor Start Up
3.4 USER SELECTABLE OPTIONS
3.4.1 Screen Lighting
3.4.2 Graphical display
3.4.3 TAG Transmitter Name
3.4.4 SENSOR Name
3.4.5 Password Protection
4.0 CALIBRATION
4.0.1 AUTO Calibration description
4.0.2 STANDardize Calibration description
4.0.3 MANUAL Calibration description
4.1 pH Calibration Procedures
4.1.1 AUTO Cal using pH 4.01, 7.00, 10.00 buffers
4.1.2 AUTO Cal using other pH buffers
4.1.3 Standardize
4.2 ORP Calibration Procedures
4.2.1 Auto Cal with Quinhydrone
4.1.2 Standardize
4.3 pION Calibration Procedures
4.3.1 AUTO Cal using 1, 10, 100 ppm solutions
4.3.2 AUTO Cal using non-decimal ppm solutions
4.3.3 Standardize
4.4 S80/DO90 DISSOLVED OXYGEN Calibration Procedures
4.4.1 AUTO Cal using zero ppm solution and Air
4.4.2 Standardize
4.4.3 Manual Cal
4.5 TRITON® DO82 Dissolved Oxygen Calibration Procedures
4.5.1 AUTO Cal using zero ppm solution and Air
4.5.2 Standardize
4.6 TRITON® TR80, TR82 or TR86 Turbidity/Suspended Solids Sensors
4.6.1 AUTO Cal
4.6.2 Standardize
4.6.3 MANUAL Cal
4.7 Conductivity Sensors
4.7.1 AUTO Cal using Air and Conductivity Standard
4.7.2 Standardize
4.8 TDS Conductivity Sensors
4.8.1 Standardize
4.9 Resistivity Sensors
4.9.1 AUTO Cal using Air and Meg-Ohm process water
4.9.2 Standardize
4.10 Ammonium Hydra-DS
4.10.1 AUTO Cal using pH 4.01, 7.00, 10.00 buffers
4.10.2 Standardize pH
4.10.3 AUTO Cal using 10 ppm and 100 ppm Potassium Solutions
4.10.4 Standardize Potassium ion
4.10.5 AUTO Cal Using 10 ppm and 100 ppm Ammonium Solutions
4.10.6 Standardize Ammonium ion
5.0 MAINTENANCE
5.1 CLEANING
6.0 TROUBLESHOOTING
7.0 PARTS AND ACCESSORIES
7.1 Front Panel Control Board Exploded
7.2 Front Panel Control Board Exploded, with Relays
7.3 Transmitter Case, back with Cable Glands
7.4 Replacement Parts
7.5 Accessories
8.0 S80 SENSORS
8.1 S80 Installation
8.1.1 Insertion
8.1.2 Immersion
8.1.3 Flow through
8.1.4 Valve Retractable
8.1.5 Flange fittings
8.2 S80 Part Number Configurator
8.3 TRITON® DO82 Sensors
8.4 TRITON® TR Series Sensors (TR80, TR82, TR86)
8.3 S80 Sensor Maintenance
8.3.1 Electrode Cartridge Installation
8.3.2 Electrode Cartridge Replacement
8.3.3 Electrode Cleaning
8.3.4 pH Electrode Cartridge Cleaning
8.3.5 ORP Electrode Cartridge Cleaning
8.3.6 pIon Electrode Cartridge Cleaning
8.3.7 Dissolved Oxygen Cartridges
8.3.8 TRITON DO82 Dissolved Oxygen
8.3.9 TRITON TR86 Turbidity
8.3.10 Conductivity and Resistivity sensors
8.4 S80 Sensor Specifications
8.4.1 pH electrodes
8.4.2 ORP Electrodes
8.4.3 Dissolved Oxygen
8.4.4 Ammonium Electrode
8.4.5 Bromide Electrode
8.4.6 Cadmium electrode
8.4.7 Calcium Electrode
8.4.8 Chloride Electrode
8.4.9 Cupric Electrode
8.4.10 Cyanide Electrode
8.4.11 Fluoride Electrode
8.4.12 Lead electrode
8.4.13 Potassium Electrode
8.4.14 Silver Electrode
8.4.15 Sodium Electrode
8.4.16 Sulfide Electrode
8.4.17 TRITON® DO82
8.4.18 TRITON® TR80, TR82, TR86
APPENDIX
A. Auto Cal Buffer Tables
B. T80 HART Menu
D. MODBUS RTU Register Listing
03 (0x03) Read Holding Registers
06 (0x06) Write Single Register
Registers
Fault Status
Warning Status
Sensor Type
E. Resistivity Temperature Compensation
F. SOFTWARE HISTORY
G. Ammonium Hydra-DS
TERMS AND CONDITIONS OF SALE
1. ACCEPTANCE. If this writing differs in any way from the terms and conditions of Buyer's order or if this writing is construed as an acceptance or as a confirmation acting as an acceptance, then Seller’s acceptance is EXPRESSLY MADE CONDITIONAL ON BUYER’S ASSENT TO ANY TERMS AND CONDITIONS CONTAINED HEREIN THAT ARE DIFFERENT FROM OR ADDITIONAL TO THOSE CONTAINED IN BUYER'S WRITING. Further, this writing shall be deemed notice of objection to such terms and conditions of Buyer. If this writing is construed as the offer, acceptance hereof is EXPRESSLY LIMITED TO THE TERMS AND CONDITIONS CONTAINED HEREIN. In any event, Buyer's acceptance of the goods shall manifest Buyer's assent to Seller's terms and conditions. No addition to or modification of these terms will be effective, unless set forth in writing and agreed to by
Seller.
2. WARRANTIES AND REMEDIES
a. Warranty. Seller warrants to Buyer that it holds and will pass marketable title to the goods sold hereunder. Seller warrants to Buyer that the items and components manufactured by Seller will be free from defects in material and workmanship (subject, however, to tolerances and variances permitted by the trade hereunder) for a period one (1) year for non-consumable products. Consumable electrodes and sensors have a conditional warranty based shelf life and process conditions and is determined by Seller.
b. Exclusion and Conditions. Seller’s obligations with respect to the express warranties and remedies contained herein are conditioned on the following: (i) Buyer's return of the non-conforming goods, if authorized by Seller: (ii) Buyer shall not assign its rights under these express warranties and any attempted assignment shall render such warranties, but not any disclaimers or limitations, void and the goods sold shall be sold AS IS; and (iii) all products shall be carefully inspected for damage by Buyer upon receipt, be properly calibrated for Buyer's particular use, and be used, repaired, and maintained by Buyer in accordance with the instructions set forth in Seller’s product literature. Repair and maintenance by non-qualified personnel, product subjected to misuse or negligence, and/or damaged during shipment will invalidate the warranty, as will the use of non-approved consumables or spare parts. As with any other sophisticated product, it is essential, and a condition of Seller’s warranty, that all personnel using the product be fully acquainted with its use, capabilities and limitations as set forth in the applicable product literature.
3. DISCLAIMER OF IMPLIED WARRANTIES. Seller gives no warranties except those expressly contained herein. Seller disclaims all other warranties implied by law usage of the trade, course of dealing or course of performance including, but not limited to, the Implied warranties of MERCHANTABILITY and fitness for a particular purpose.
4. LIMITATIONS OF LIABILITY. The following limitations of Seller's liability are acknowledged by the parties to be fair and reasonable and shall apply to any act or omission hereunder, and to any breach of this contract of which these terms and conditions form a part:
a. Disclaimer of Damage. In no event shall Seller be liable for special, indirect, consequential or incidental damages whether arising under contract, warranty, tort, strict liability or any other theory of liability. Such damages include but are not limited to loss of profits, loss of use of goods, damage to property, and claims of third parties.
b. Suitability. Buyer acknowledges that it alone has determined the intended purpose and suitability of the goods sold hereunder. It is expressly agreed by the parties that any technical or other advice given by the Seller with respect to the use of the goods or services is given without charge and at Buyer's risk;
therefore Seller assumes no obligation or liability for the advice given or results obtained.
c. Notice and Time of Claims.
i. Buyer agrees to check and inspect all products against shipping papers and for damage or shortage upon receipt of goods at destination.
ii. Every claim for shortage, damage in transit, or other cause visible upon inspection shall be deemed waived by the Buyer, or the Buyer’s customer in the case of resale, unless delivered in writing to Seller by Buyer thirty (30) days from the tender of delivery of the goods to Buyer, provided, however, that claims for shortage must be made within seven (7) days of receipt.
iii. The parties expressly waive the statute of limitations and agree that any legal proceeding for any breach of this contract shall be waived unless filed within one (1) year after the accrual of the cause of action thereof.
5. FORCE MAJEURE. Seller shall not be liable for any delay in delivery, or failure to deliver, due to any cause beyond the Seller’s control including but not limited to fires, floods, or other forces of the elements; strikes, or other labor disputes; accidents to machinery; acts of sabotage; riots; precedence or priorities granted at the request or for the benefit, directly or indirectly of the federal or any state government or any subdivision or agency thereof; delay in transportation or lack of transportation facilities; restrictions imposed by federal, state or other governmental legislation or rules or regulations thereof. If Seller, in its sole discretion, determines that Seller’s performance hereunder would result in a loss to Seller’s on this sale as computed under Seller’s normal accounting procedures because of causes beyond Seller's control, then the Seller may terminate this agreement in whole or in part without liability for any delay in the delivery of, or failure to deliver, the goods sold hereunder
6. TAXES AND OTHER CHARGES. The Buyer will pay, or reimburse Seller if it pays, any and all taxes or tariffs or any other similar charges imposed upon this contract, the goods covered hereby or the delivery or use or resale thereof.
7. FREIGHT CHARGES. If the sale hereunder is other than F.O.B. Seller's facility, this acknowledgement is based upon the freight charges now in effect. In the event of an increase or decrease in applicable freight charges before the goods are shipped, such charge in freight will be for the Buyer's account.
8. PRICES AND DELIVERY. Prices quoted herein are F.O.B. shipping point. Deliveries specified are only our best estimate and are subject to change. This quotation is based upon freight charges now in effect. Buyer will be invoiced at the freight charge prevailing at the date of shipment. Prices are firm for orders meeting Seller's normal shipping schedules. If shipments are held or postponed for any reason other than Seller's fault, and a price increase becomes effective during the period of such hold or postponement, the increase will apply to all shipments that are held or postponed thirty (30) days or more from the effective date of the increase.
9. PAYMENTS. If in the judgment of Seller the financial condition of Buyer at any time prior to shipment does not justify the terms of payment specified, Seller may cancel the order, withhold shipment, and/or require full or partial payment in advance. If payment is not made when due, Seller may suspend all future delivery or other performance with respect to Buyer without liability or penalty and, in addition to all other sums payable hereunder, Buyer shall pay to Seller (i) the reasonable costs and expenses incurred by
Seller in connection with all actions taken to enforce collection or to preserve and protect Seller’s rights hereunder, whether by legal proceedings or otherwise, including without limitation reasonable attorneys’ fees, court costs and other expenses and (ii) interest on all amounts unpaid after 30 days charged at the monthly rate of 1-1/2% or the highest rate permitted by law, whichever is lower.
10. CANCELLATION OR ALTERATION. Buyer may not alter or cancel any order without Seller’s written consent. For any order altered or cancelled with Seller's consent, Buyer must pay for all expenses and labor incurred up to the time of Seller’s consent, plus a reasonable percentage for profit. Any order delayed or deferred by Buyer will be subject to price escalation for increased costs of production, and any other expenses caused by the delay. Material on such orders will be stored at Buyer's risk. Seller reserves the right to invoice Buyer and require payment before shipment of any delayed or deferred order.
11. TITLE AND RISK OF LOSS. Title and risk of loss shall pass to buyer at Anaheim, California, unless otherwise specified in the contract. If delivery is made by common carrier, risk of loss shall pass upon delivery to the carrier. Claims for loss or damage in transit must be made by Buyer to the carrier. Seller accepts no responsibility for loss or damage to product in transit.
12. PATENT OR TRADEMARK INFRINGEMENT. If the goods sold hereunder are to be prepared for manufacture according to Buyers specification, Buyer shall indemnify Seller against any claim or liability for patent, trademark, service mark or trade name infringement on account of preparation, manufacture and/or sale.
13. NON-WAIVER. If Government Contract Regulations require the addition, deletion, or modification of these terms and conditions upon prior notification to Seller and Seller's written acceptance thereof, such changes shall become a part of these terms and conditions. Seller shall not be bound by any Government Contract Regulations applicable to
Buyer’s contracts with the U.S. Government unless Buyer has expressly acknowledged, on the face of this document, the applicability of such Regulations to the transaction between Buyer and Seller contemplated herein. Absent such acknowledgement, Seller is making the assumption in issuing this document that no such Regulations apply.
Page 10 Model T80
14. JURISDICTION. All such disputes shall be resolved in a court of competent jurisdiction in Orange County, California. Buyer hereby consents to the jurisdiction of the State and
Federal Courts sitting in Orange County. Not withstanding the above, should either party contest the jurisdiction of such courts, the other party may institute its suit in any court of competent jurisdiction.
15. APPLICABLE LAW. All questions arising hereunder or in connection with the quotations or any order submitted in connection therewith and/or the performance of the parties hereunder shall be interpreted and resolved in accordance with the laws of the state of California without regard to its conflict of law provisions and excluding the United
Nations Convention on the International Sale of Goods.
RETURN GOODS POLICY
All requests for returned goods must be initiated through our Customer Service Department. Please call our phone number (714) 695-0051 with the specifics of your request. The following conditions must be satisfied for consideration of applicable credit for the return of products purchased from Electro-Chemical Devices:
1) The item is unused and in the original package.
2) The item was shipped directly from Electro-Chemical Devices.
3) The item has not been damaged in shipment to Electro-Chemical Devices.
4) Items containing date-sensitive parts such as electrodes, must be returned within 1 month of the invoiced date.
5) Items without date-sensitive parts must be returned within 3 months of the invoiced date.
A Return Merchandize Authorization Number must be obtained from Customer Service and be provided on all paperwork and packaging. To obtain a Return Merchandize Authorization Number, please provide the reason for return, the date of purchase, your original purchase order number, and either our order number or our invoice number. The issuance of a Return Merchandize Authorization Number is a verbal approval for return only and does not guarantee credit or allowance. Returned goods must be received within 30 days of the issuance date of the Return Merchandize Authorization Number or it will become null and void.
Necessary physical and mechanical inspection is completed upon receipt of the item. Applicable credit or equivalent allowance is determined after inspection of the returned item. If all of the above conditions are met, and the item has been approved to return to our stock, a restocking charge of 25% of the purchase price is deducted from the applicable credit.
UNPACKING THE INSTRUMENT
Your Electro-Chemical Devices instrument has been carefully packaged to protect it from damage during shipment and dry storage. Upon receipt please follow the procedure outlined below.
1. Before unpacking, inspect the condition of the shipping container to verify proper handling by the carrier. If damage is noted, save the shipping container as proof of mishandling for the carrier.
2. Check the contents of the shipping container with the items and quantities shown on the packing list.
Immediately report any discrepancies to ECD.
3. Save the original packing material until you are satisfied with the contents. In the event the product(s) must be returned to ECD, the packing material will allow you to properly ship it to ECD.
4. Familiarize yourself with the instrument before installation, and follow proper installation and wiring procedures.
Installation and wiring
Failure to follow the proper instructions may cause damage to this instrument and warranty invalidation.
Use only qualified personnel to install, operate and maintain the product.
The Model T80 transmitter should only be used with equipment that meets the relevant IEC, American or
Canadian standards. ECD accepts no responsibility for the misuse of this unit.
Basic Parts List
1. Model T80 Transmitter
2. Mounting Hardware
3. Instruction Manual
INSTRUCTION MANUAL REVISION
Revision Date Remarks
A 07/12 Initial release
B 03/13 Added Sensors and Conductivity Data
C 03/13 Updated Symbols
D 07/13 MODBUS Update
E 07/13 Turbidity, Conductivity, Cal Menu
F 05/14 Two Channels, MODBUS Update, G 07/15 Resistivity Calibrations added
H 08/15 S80 Table Corrected
I 09/15 Icons Deleted
K 12/15 New Location
L 05/16 Salinity added
M
N
O
06/17
03/18
05/18
Update Turbidity, DO, pIon
Ammonium Hydra-DS
MODBUS Update
Page 12 Model T80
WARNING Electrical installation must be in accordance with the National Electrical Code
(ANSI/NFPA-70), Canadian Electrical Code and/or any other applicable national or local codes.
1.0 GENERAL DESCRIPTION
The ECD Model T80 transmitter is a single or dual channel, intelligent, multi-parameter transmitter designed for the online continuous measurement of pH, ORP, pION, dissolved oxygen, conductivity, resistivity and turbidity in a general purpose industrial environment. The Model T80 transmitter digitally communicates with any
ECD S80 digital sensor, automatically configuring the transmitter menus and display screens to the measured parameter.
The Model T80 transmitter can be loop powered, 24 VDC powered or 100-240 VAC line powered. The standard configuration has a 4-20 mA output and a RS485 serial communication port with MODBUS®RTU output. A HART® communication version (single channel version only) is also available. Alarm relays are optionally available on either line powered transmitter.
1.1 FEATURES
Multi-Parameter, pH, ORP, Specific Ion, Dissolved Oxygen, Conductivity, Resistivity
Simple, user friendly menu structure
Noise free digital communication with sensors
Reads and writes calibration data to sensor
Dual Channel option has interactive channels, pH compensated readings, interfering ion corrections…
Non-Isolated 4-20 mA output and MODBUS® RTU standard, optional HART®
1.2 SPECIFICATIONS
1.2.1 INPUT SPECIFICATION
Digital protocol, all ECD S80 sensors
Optional analog to digital converter, 5 inputs [mV+, mV-, solution ground, temp + temp - (100 K-ohm)]
1.2.2 INPUT RANGES
pH -1.00 - 15.00 pH
ORP -1500 - +1500 mV pION 000.1 - 999.9, Auto Ranging: ppb ↔ ppm ↔ ppT (thousand) Dissolved Oxygen 000.1 - 999.9, Auto Ranging: ppb ↔ 20.00 ppm, % SAT, mg/L Conductivity 0.000 - 2.000, Auto Ranging: µS ↔ mS ↔ S
TDS 0.00 - 9999 ppm
Resistivity 0.00 - 50.00 MΩ
Turbidity 0 - 4000 NTU/FNU, 0 – 99999 ppm, mg/l, 0-100% %solids
Temperature 100 K-ohm TC, -30°C - 140°C
1.2.3 ACCURACY
pH 0.02 pH
ORP ± 1 mV pION Specific to electrode type
Dissolved Oxygen 2% of range
Conductivity 2% of range
Resistivity 2% of range
Turbidity 2% of reading
Temperature ± 0.3°C
1.2.4 OUTPUT SIGNALS
Non-isolated 4-20 mA output (standard, one per Channel), Fault Condition: 3.5 mA, 22 mA or none
Modbus RTU (standard)
HART® (optional)
1.2.5 CONTACT RELAYS
(Optional) Three (3) SPDT, 1 form C, 250 VAC, 10 Amp resistive maximum, relays, user configurable as Hi/Lo alarms with expiration timer, Periodic Timers or Fault alarms
1.2.6 DISPLAY
128 x 64 pixels (2.75” x 1.5”) LCD, Black on Grey background on loop powered instruments, Blue on White background with LED backlight on 100-250 VAC and 24 VDC powered instruments, English or icon based menus, numeric and graphical displays
1.2.7 ENCLOSURE
Beige Polycarbonate, IP65, weatherproof, ½ DIN, (L x W x D) 5.7” X 5.7” X 3.5” (14.4cm X 14.4cm X 9.0cm)
1.2.8 POWER
Code -0 Loop powered, 24 VDC 600 Ω maximum load (18-36VDC @ 0.3W Maximum)
Code -1 24 VDC (18-36 VDC @ 4W Maximum)
Code -2 100-240 VAC, 50/60 Hz, 4W, protected with 250V, 1A, Slow Blow fuse
1.2.9 ENVIRONMENTAL CONDITIONS
Outdoor use (IP65)
Ambient Temperature -20°C - 70°C (24 VDC Models)
-20°C - 60°C (100-240 VAC Models)
Storage Temperature -30°C - 85°C
Relative Humidity 0 – 80%, up to 31°C
Decreasing linearly to 50% RH a 40°C
Altitude Up to 2000 m (6500 ft)
Mains Supply Voltage Fluctuations up to ±10% of the nominal voltage
Transient over voltages: CAT II
Pollution Degree: 2
1.2.10 SHIPPING
Size 8” x 8” x 5” (20.5 cm x 20.5 cm x 12.7 cm)
Weight 1.6 lbs. (0.75 kg)
Page 14 Model T80
1.3 MODEL CODES
Model T80-
1st Channel 1 (S80) S80 Digital Sensor, pH, ORP,pION,DO,DO90 ppb DO,Conductivity,Resistivity,TR Series, DO82
3 Internal Preamp, Digital to pH Steam Sterilizable Products
4 Internal Preamp, Digital to SGTC Conductivity/Resistivity (CSX2 or 2 electrode contacting )
2nd Channel 0 No Second Channel
1 (S80) S80 Digital Sensor, pH, ORP, pION, DO, Conductivity, Resistivity, DO82,TR Series
Power Supply -0 Loop Powered Transmitter
-1 24 VDC Powered Transmitter
-2 100-240 VAC powered Transmitter
Relay Option 0 No Relays
1 (3) form 1C 250 V 3A relays
Outputs 0 4-20 mA output and MODBUS
1 HART®
2 2 x 4-20 mA & MODBUS
3 Hart (Channel one only) & (2x) 4-20 mA
Mounting
Hardware
00 No Mounting
01 Universal
02 Panel Mount
03 Handrail Mount
04 Sunshield Pole
05 Sunshield Rail
Model T80- 1 1 -2 1 2 01
Example above shows part# T80-11-212-01, a two channel T80 transmitter for use with two S80 sensors, 110/220 VAC powered with two 4-20 mA outputs and MODBUS RTU and a universal mounting bracket.
2.0 INSTALLATION
2.1 MOUNTING
Mount the T80 in a location where there is easy access to the analyzer and sensors. Install the system in an area where vibrations, electromagnetic and radio frequency interference are minimized or absent. Do not mount in direct sunlight or areas of extreme heat (temperature > 120°F). The IP65 T80 is suitable for outdoor use but it is best to mount it with a protective cover or sunshield to prevent discoloring over the years.
Universal Mounting Brackets
Rail Mounting
Page 16 Model T80
Panel Mounting
Cut Out: 5.35” x 5.35” (13.6 cm x 13.6cm)
2.2 WIRING
Electrical wiring should only be conducted by qualified personnel. See the T80 wiring diagram in Figure 2.2.X
Figure 2.2.1 Loop Powered Transmitter (S80’s only – not for DO82, TR80, TR82, TR86)
Figure 2.2.2 4-Wire Transmitter, 24VDC or /110/220 VAC, MODBUS, Relays/Optional Digital Preamp
Figure 2.2.3 4-Wire Transmitter, Model TR80, TR86, TR80, TR82 turbidity or Model DO82 Dissolved Oxygen sensors
Page 18 Model T80
Warning: RISK OF ELECTRICAL SHOCK
Disconnect Power before opening instrument.
WARNING Electrical installation must be in accordance with the National Electrical Code
(ANSI/NFPA-70), Canadian Electrical Code and/or any other applicable national or local codes.
2.2.1 WIRING, POWER
ECD recommends using a thermoplastic, outdoor sunlight resistant jacketed cable, wet location rated and ½” flexible conduit. The power should be hard wired with a switch or breaker to disconnect the analyzer from the main power supply. Install the switch or breaker near the analyzer and label it as the Power Switch for the analyzer.
Loop Powered (2 wire configuration)
Attach the 24VDC signal cable to terminals #1 and #2 as shown in Figure 2.2.1 and on the diagram inside of the
T80 cover. Feed the cable through the gland fitting on the right hand side of the T80. Tighten the cable gland to provide a good seal to the cable. The instrument can be powered up at this point with no harm to the analyzer but it is best to wait until the sensor is installed.
24VDC (4 wire configuration)
Attach the 24VDC power cable to terminals #1 and #2 as shown in Figure 2.2.2 and on the diagram inside of the
T80 cover. Attach the 4-20 mA1 cable to terminals #3 (out) and #2 (return)single channel unit and attach the 4-
20 mA2 cable to terminals #4 (out) and #2 (return) for a two channel instrument. Feed the cables through the gland fitting on the right hand side of the T80. Tighten the cable gland to provide a good seal to the cable. The instrument can be powered up at this point with no harm to the analyzer but it is best to wait until the sensor is installed.
110/220 VAC (4 wire configuration)
Attach power cable as shown in Figure 2.2.2 or as on the diagram inside of the T80 cover. Feed the cable through the gland fitting on the right hand side of the T80. Tighten the cable gland to provide a good seal to the cable. The instrument can be powered up at this point with no harm to the analyzer but it is best to wait until the sensor is installed.
Page 19 Model T80
2.2.2 WIRING, SENSOR
Attach the sensor wires as described on the diagram inside the T80 cover. Feed the sensor cable through the gland fitting on the left hand side of the T80. Do not use the same gland fitting for the AC power or
Alarm/Relays. The green terminal strip connectors are detachable from the circuit boards. Remove the connector by pulling straight back from the circuit board.
2.2.3 WIRING, 4-20 MA OUTPUTS
Loop Powered Instruments:
Connect the 4-20 mA cable to terminals #1 (+24V) and #2 (-24V), Model T80-XX-0 X-XX.
24 VDC or 110/220 VAC powered instruments:
For instruments powered with 24VDC or the internal power supply, Model T80-XX-1X-XX (24VDC) and T80-XX-
2X-XX (110/220 VAC), connect the 4-20 mA cable(s) to terminals #3 (out) for channel 1 and #2 (return) and to terminals #4 (out) for channel 2 and #2 (return).
Transmitters with HART® Communication can be wired as shown below. See HART® Communication menu in
Appendix 9.2:
2.2.4 WIRING, CONTACT RELAY OUTPUTS
The standard configuration has three SPDT 230V 5 A relays that can be wired either normally open (NO) or normally closed (NC). The default configuration is set to use the relays as normally open.
2.2.5 WIRING, SERIAL OUTPUT MODBUS RTU
Attach the sensor wires as shown in Figure 2.2.2 or as described on the diagram inside the T80 cover. Feed the sensor cable through the gland fitting on the left hand side of the T80. Do not use the same gland fitting for the
AC power or Alarm/Relays. See MODBUS command register in Appendix D.
Page 20 Model T80
3.0 OPERATION
The ECD Model T80 transmitter is an intelligent, single or dual channel multi-parameter transmitter designed for the online continuous measurement of pH, ORP, pION, conductivity, resistivity or Dissolved Oxygen in a general purpose industrial environment.
The Model T80 transmitter digitally communicates with any ECD S80 digital sensor. The measurement identity is contained in the sensor’s memory. When an S80 sensor is connected to the transmitter it automatically configures the transmitter’s menus and display screens to the measured parameter.
3.1 KEYS
The functions associated with each key are displayed on the screen, above the key for the Selection Adjustment
Keys and to the left of the key for the HOME and BACK keys. Press any Selection Adjustment key twice within one second to enter the HOME Menu Screen.
3.1.1 HOME/EXIT KEY
The HOME key performs two functions, it selects which Home Screen is displayed and it returns the active screen to the HOME Menu Screen from anywhere inside the menu structure.
Three Display screens are available:
1. DATA SCREEN: Displays the measurement type, numerical value, engineering Units, % Output of the 4-20 mA channel and temperature.
2. mV SCREEN: Displays the measurement type, the sensor’s raw millivolt Value, % Output of the 4-20 mA channel and temperature.
3. GRAF SCREEN: Displays a Graphical representation of the 4-20 mA channel
% Output, the measurement type, the engineering units, and temperature.
Only one of the three graphical display styles is available through the HOME key, either the Bar, Gauge or Line display. Choose which style will be displayed in the Graph Menu. (pathway to Graph Menu: CONFIG → XMTR
→ LCD → Graph menu)
Each of the above screens also displays the condition of the optional Alarm Relays, black if energized and white if de-energized.
The HOME key changes to the EXIT key in the HOME Menu Screen, pressing EXIT prompts the user to “Save Changes” YES/NO when exiting the HOME Menu. YES applies any changes made in the menus, NO exits the HOME Menu without applying any changes made in the menus.
3.1.2 BACK/HOLD KEY
The BACK key changes the screen to the previously displayed screen when inside a menu, it moves BACK one screen. On a dual channel transmitter it toggles between the PV1, PV2 and Dual
Channel Screens. The HOLD key toggles the output HOLD function ON/OFF in the MENU HOME screen.
Page 21 Model T80
3.1.3 SELECTION ADJUSTMENT KEYS
The (4) Selection/Adjustment keys allow navigation and numerical adjustments to be made in the MENUs. To enter the HOME Menu screen press any of the Selection/Adjustment keys twice within one second. The various Menu choices and adjustment tools are displayed above the buttons once inside the MENU.
3.1.4 ALPHA NUMERIC ENTRY
The LABEL and PASSWORD (Caps and Numbers only) Menus allow alphanumeric entry. Entry is accomplished by scrolling through the alphanumeric list with the ▲ (forward) and ▼ (backwards) arrows to the character of choice and then moving to the NEXT digit. Pressing and holding the ▲ or ▼ keys will initiate two speed auto scrolling. The character set is sequentially listed below. The first character in the set is an empty space.
! ” # $ % & ‘ ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ? @ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ ¥ ] ^ _
‘ a b c d e f g h I j k l m n o p q r s t u v w x y z { | } → ←
3.2 MENU STRUCTURE
Double tap any Selection/Adjustment key to enter the HOME Menu Screen. Five menu choices will appear, CAL, CONFIG, INFO, SIM and HOLD. Each of the Menus is detailed below.
3.2.1 HOLD (OUTPUT HOLD)
Pressing the HOLD Key activates the HOLD function, HOLD is ON, displayed.
Freezes the 4-20 mA output at the last value prior to activation
Freezes optional Alarm Relays in the current state
While in the HOLD mode the % Output display toggles between the last value and HOLD
Pressing HOLD again turns the hold function off, Hold is OFF, displayed. The HOLD function remains ON until it is turned OFF. (See Time Out in CONFIG>XMTR>OUTPUT>HOLD)
3.2.2 CAL (CALIBRATION MENU)
Four options are available, AUTO, STAND, MANUAL and TEMP. On dual channel instruments choose Sensor 1 or
Sensor 2 when prompted.
The first screen asks, “Is this a New Sensor, YES / NO”. If YES the calibration history from the previous sensor is cleared from memory and a new register is started, if NO then the calibration is written to the memory stack, (3) sets of data are stored.
AUTO is a two point calibration. The calibration proceeds in two steps, AutoCal 1 is an offset calibration and AutoCal 2 is a slope calibration. Auto Cal provides automatic solution recognition of the calibration solutions used for each measurement in accordance with the following list:
1. pH Calibration Buffers (US Standard), pH 4.01, pH 7.00 and pH 10.00 (see Appendix A)
2. ORP Calibration Solutions: Quinhydrone saturated: pH 4.01= +89 mV, pH 7.00= +266 mV
3. pIon Calibration Solutions: 1.00, 10.00, 100.0 ppb, ppm, ppt
(thousand)
4. Dissolved Oxygen: Zero ppm (Sodium sulfite, Na2SO3 in water), Air saturated water, 8.25 ppm
Any two solutions can be used for AUTO calibration however if solutions other than those listed above are used for calibration then the calibration values must be entered manually.
STAND is standardization, a single point calibration. Standardizations are typically used to adjust the process reading to agree with a laboratory determined “grab sample” reading.
MANUAL is a data entry screen. Manual calibration allows the user to enter a concentration with the corresponding mV value and a slope for an electrode. Laboratory generated calibration data for an electrode can be input to a remote analyzer where calibration is difficult or impractical.
TEMP allows the displayed temperature to be trimmed to agree with actual process temperature.
3.2.3 CONFIG (CONFIGURATION MENU)
Four options are available in the Configure Menu, XMTR, SENSOR, LOAD DEFAULT and Dampen.
XMTR enters the Transmitter Configuration menu.
o LCD access the Display Configuration Menu
SETUP adjust screen lighting characteristics
Temp. Choose °C or °F
CONT adjust Contrast
BACK LIGHT adjust Backlight Timeout, from always ON to OFF after 10 minutes
GRAPH provides the choice of which Graph style is displayed on the Home screen.
LINE , Moving average, vertical scale set to 0-100% of the 4-20 mA output and user defined time scale
GAUGE, Current reading 0-100% of 4-20 mA range
BAR, Current reading 0-100% of 4-20 mA range
LABELS
TAG, Enter up to 2 lines x 16 characters, example, Name, tag #... Displayed in INFO screen
TAG ON, Turn TAG ON/OFF, adds TAG to Main
Display Sequence, DATA → mV → GRAF → TAG →
DATA
POP UP, Turns ON/OFF, the double tap HOME Screen pop up memo
SENSOR, Enter up to 2 lines x 16 characters o OUTPUT access the Output Configuration Menu
4-20 mA configure 4-20 mA output (PV or Temp or More)
RA…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .