19GE5022R0019 Attachment 3

Contractor Furnished Materials and Government Furnished Property

A - CONTRACTOR FURNISHED MATERIALS

The Contractor shall provide all equipment, materials, vehicles, uniforms and supplies required to perform. Such items include, but are not limited to:

• Alarm equipment compatible to internet access/reporting.

Alarm systems inclusive of

• Touchscreens

• Electrical connections

• Long-life lithium battery back-ups

• Sensors

• Panic alarm buttons/Touchscreens with such features

• All necessary wiring and cabling

• Central alarm panels

• Sirens and strobe lights

• Operating instructions in English

• Alarm schematic/diagrams

The Contractor shall maintain sufficient spare parts, etc., for all Contractor-furnished materials to ensure uninterrupted services.

B - GOVERNMENT FURNISHED PROPERTY

LIST OF CURRENT GOVERNMENT OWNED ALARM SYSTEMS*

BRAND MODEL NUMBER ESTIMATED

QUANTITY

Digital Monitoring

Products (DMP)

XR550/XR150 and related alarm equipment

Bosch DS7400 170

Risco Rokonet 3

* The alarm systems that are offered under this contract have to be compatible with current owned alarm systems

❖ DMP 1100 Series Wireless Transmitters

Wireless Keypads

9060/9063 Thinline Series Keypad

Standby Battery Time 24 Hours

Dimensions 7" W × 5.25" H × 0.5" D

9862/9862USB Graphic Touchscreen Keypad

Standby Battery Time 24 Hours

Dimensions 5.8" W × 4.135" H × 0.6" D

Wireless Repeater/Receivers

1100D/1100DE Wireless Receiver

Frequency Range 905-924 MHz

Operating Voltage 8.0 to 14 VDC

Current Draw 40 mA

Housing Dimensions 5.5” W × 3.75” H × 1” D

Flame-retardant ABS constructed housing

1100R/1100RE Wireless Repeater

Frequency Range 905-924 MHz

Operating Voltage 8.0 to 14 VDC

Housing Dimensions 4.65" L × 1.4" W × 3.1" H

Flame-retardant ABS constructed housing

1100X/1100XE Wireless Receiver

Frequency Range 905-924 MHz

Operating Voltage 8.0 to 14 VDC

Current Draw 40 mA

Housing Dimensions 4.65" L × 1.4" W × 3.1" H

Flame-retardant ABS constructed housing

XTLplus Onboard Receiver

Operating Voltage 12 VDC (Model 372-500-W)

Frequency Range 905-924 MHz

Housing Dimensions 5.5" W × 3.75" H × 1" D

XT50 Onboard Receiver

❖ DMP XR550 Control Panel

❖ DMP Graphic Touchscreen Keypad

Specifications

Operating Voltage 12 VDC

Dimensions (7800) 5.8" W × 4.13" H × 0.6" D

Dimensions (9800) 5.8" W × 4.1" H × 0.8" D

Display Type Full-color graphic LCD

Display Size 5.0" (15:9 diagonal)

Colors Gloss Black or White

Compatibility

7872/7873 XT30|XT50 and XR150|XR550 Panels

9862/9862USB XT, XTL, and XR150|XR550 Panels

Current Draw

Standby 145 mA + 1.6 mA per active zone

Alarm 215 mA + 2 mA per active zone

Standby 143 mA + 1.6 mA per active zone

Alarm 222 mA + 2 mA per active zone

Standby 120 mA + 1.6 mA per active zone

Alarm 206 mA + 2 mA per active zone

Certifications

7872/7873

California State Fire Marshal (CSFM)

FCC Part 15 RFID Reader FCC ID: CCKPC0131

Industry Canada ID: 5251A-PC0131

ETL Listed:

ANSI/UL 294 Access Control

ANSI/UL 365 Police Connected Burglar

ANSI/UL 609 Local Burglar

ANSI/UL 1023 Household Burglar

ANSI/UL 1076 Proprietary Burglar

ANSI/UL 1610 Central Station Burglar

ANSI/UL 985 Household Fire Warning

9862/9862USB

FCC Part 15: CCKPC0132

Industry Canada ID: 5251A-PC0132

ETL Listed:

ANSI/UL 1023 Household Burglar

ANSI/UL 1076 Proprietary Burglar

ANSI/UL 1610 Central Station Burglar

❖ DMP Wireless Receivers, Repeaters & Translators

Flame-retardant ABS constructed housings

1100D/1100X/1100DE/1100XE Receiver

Operating Voltage 8.0 to 14 VDC

Current Draw 35 mA

Dimensions 5.5" W × 3.75" H × 1" D

1100DH/1100XH/1100DHE/1100XHE Receiver

Operating Voltage 8.0 to 14 VDC

Current Draw 100 mA

Dimensions 5.5" W × 3.75" H × 1" D

1100DI Receiver

Operating Voltage 8.0 to 14 VDC

Current Draw 45 mA

Housing Dimensions 3.3" L × 1.6" W × 1.2" H

1100R/1100RE Repeater

Operating Voltage 8.0 to 14 VDC

Dimensions 5.5" W × 3.75" H × 1" D

1100T Translator

Operating Voltage 12 VDC, 23 mA

Standby Battery

Voltage 3.7 VDC

Capacity 800 mAh

Type Lithium Polymer, rechargeable

Standby 4 hours

Dimensions 5.50" W × 3.75" H × 1.00" D

1100TF Translator

Operating Voltage 12 VDC, 31 mA

Standby Battery

Voltage 3.7 VDC

Capacity 2400 mAh

Type Lithium Polymer, rechargeable

Standby 24 hours

Dimensions 5.50” W × 3.75” H × 1.00” D

❖ BOSCH DS7400Xi Series Addressable Control Panels

• Up to 248 zones in up to eight areas

• 400-event history buffer

• Up to 200 personal ID numbers (PINs)

• Up to 112 wireless devices

• Up to 15 keypads and/or door access control modules (DACMs)

❖ Two Independent Entry Delays

• Program zones to select from one of the two entry delay times.

• Users can select a longer entry delay time for zones located a long distance from the keypad.

❖ Easy Function Key User Interface

• Six labeled function keys eliminate the need for multi-button commands.

• Enter a PIN followed by the function key to perform functions such as arming, disarming, and resetting smoke detectors.

• The interface provides new users with easy to follow procedures.

• Expert users can quickly access items.

• A programmable Quick Arm feature allows users to turn the system on without a PIN. The system requires a PIN to turn off the system, silence alarms, or perform system tests

❖ Eight Areas

• Divide the control panel into eight separate system areas, each area with its own keypads and reporting ID. Keypads can be programmed as master keypads, allowing access to all areas.

❖ Flexible Digital Communication

• The communicator works with most alarm receivers, and supports 3/1, 4/1, 4/2, Contact ID, SIA, BFSK digital communicator formats and pager format. The pager format allows the control to dial a digital pager service and leave a numeric message representing the account number and event code

❖ Two Independent Entry Delays

• Program zones to select from one of the two entry delay times.

• Users can select a longer entry delay time for zones located a long distance from the keypad.

❖ DS7447V2 Alphanumeric Keypad

• Two lines, freely programmable display allows 16 characters of custom text to be programmed for zone and area descriptions.

• The user can adjust the sounder volume and backlight intensity using easy two-button commands.

The DS7447V2 is required for system programming.

❖ Texecom Speech dialer

• Outstanding Features

• 32 Character LCD Display •4 Voice Messages - Each up to 32 Seconds in Length

• 2 Programmable Outputs •Remote Access via Touch-tone Phone

• 4 Trigger Inputs •Upload/Download via Wintex™ Software††

• Call Acknowledgement •Context Sensitive Help

• Listen-in Mode •Passcode Protected

• Talkback Mode

• 8 Contact Numbers

• Memo Feature

• Call Abort

• Speech & Text Dialer

4 Text Messages - Each up to 32 Characters in Length

❖ Risco ProSYSTM Plus Security System

EN Security Grade Grade 3 or 2, selectable

Zones 128-512

Partitions 32

Groups per partition 4

Wireless zones 256

User codes 500

Event log 2000

Programmable outputs 6-262

Account numbers 32

Reporting formats Contact ID, SIA, SIA IP, SIA + Text

Wired keypads 48

2-Way Wireless Keypads 32 Slim Keypads

Wired or Wireless Sounders 32

Proximity key readers 64

Voice module with full menu guide - 2-way VOX for automatic switching between listen-in and speak-in

- Pre-recorded or user-recorded messages for zones, partitions, outputs

- Remote operations such as acknowledge event, arm/disarm, activate output

Zone resistance Fully selectable (2.2K default)

Housing Metal

Ethernet (IP) Plug-in modules

GSM 2G/3G Plug-in modules

PSTN Plug-in modules

❖ Risco 2-Way Wireless Multi-Function Contact (model RWX73F)

GENERAL DESCRIPTION

The RWX73F is a 2-way multi-function supervised transmitter with two separate channels that combines Magnetic/Door contact with two additional inputs (one universal and the other universal or shutter). The RWX73F has two reed switches for protection against opening doors and windows, and against any attempt to tamper with the detector using large magnets. The

RWX73F operates with RISCO Group 2-Way wireless systems.

❖ Risco Elegant Keypad Models: RPKELW, RPKELWP, RPKELB, RPKELBP

❖ Risco 2-Button Panic Keyfob

❖ Risco 2-Way Wireless Expander

Main features

Support for RISCO’s range of 2-Way wireless sounders, slim keypads, 8-button keyfobs and detectors

Up to 4 2-Way wireless slim keypads

Up to 32 supervised wireless zones (bus mode)

Up to 16 multi-function keyfobs (bus mode)

Up to 200 stand alone keyfobs (bus and stand-alone modes)

Two utility outputs

Rolling code technology

Signal jamming detection

Threshold-level calibration

Tamper detection

Transmitter supervision low battery detection

Nominal center frequency: 868.65 MHz or 433.92 MHz

Can be installed inside or outside the LightSYS main enclosure

Up to two WL Expanders per LightSYS system

C - RESIDENCES

The exact addresses and types of alarm systems will be provided upon award of the contract

Approximately 263 residences in Brussels/Antwerp need alarm systems.

Approximately 90 residences in Brussels are already equipped with alarm systems.

Approximately 163 residences in Brussels/Antwerp need yearly alarm system maintenance in

2022.