19GE5022R0019 Attachment 3
Contractor Furnished Materials and Government Furnished Property
A - CONTRACTOR FURNISHED MATERIALS
The Contractor shall provide all equipment, materials, vehicles, uniforms and supplies required to perform. Such items include, but are not limited to:
• Alarm equipment compatible to internet access/reporting.
Alarm systems inclusive of
• Touchscreens
• Electrical connections
• Long-life lithium battery back-ups
• Sensors
• Panic alarm buttons/Touchscreens with such features
• All necessary wiring and cabling
• Central alarm panels
• Sirens and strobe lights
• Operating instructions in English
• Alarm schematic/diagrams
The Contractor shall maintain sufficient spare parts, etc., for all Contractor-furnished materials to ensure uninterrupted services.
B - GOVERNMENT FURNISHED PROPERTY
LIST OF CURRENT GOVERNMENT OWNED ALARM SYSTEMS*
BRAND MODEL NUMBER ESTIMATED
QUANTITY
Digital Monitoring
Products (DMP)
XR550/XR150 and related alarm equipment
Bosch DS7400 170
Risco Rokonet 3
* The alarm systems that are offered under this contract have to be compatible with current owned alarm systems
❖ DMP 1100 Series Wireless Transmitters
Wireless Keypads
9060/9063 Thinline Series Keypad
Standby Battery Time 24 Hours
Dimensions 7" W × 5.25" H × 0.5" D
9862/9862USB Graphic Touchscreen Keypad
Standby Battery Time 24 Hours
Dimensions 5.8" W × 4.135" H × 0.6" D
Wireless Repeater/Receivers
1100D/1100DE Wireless Receiver
Frequency Range 905-924 MHz
Operating Voltage 8.0 to 14 VDC
Current Draw 40 mA
Housing Dimensions 5.5” W × 3.75” H × 1” D
Flame-retardant ABS constructed housing
1100R/1100RE Wireless Repeater
Frequency Range 905-924 MHz
Operating Voltage 8.0 to 14 VDC
Housing Dimensions 4.65" L × 1.4" W × 3.1" H
Flame-retardant ABS constructed housing
1100X/1100XE Wireless Receiver
Frequency Range 905-924 MHz
Operating Voltage 8.0 to 14 VDC
Current Draw 40 mA
Housing Dimensions 4.65" L × 1.4" W × 3.1" H
Flame-retardant ABS constructed housing
XTLplus Onboard Receiver
Operating Voltage 12 VDC (Model 372-500-W)
Frequency Range 905-924 MHz
Housing Dimensions 5.5" W × 3.75" H × 1" D
XT50 Onboard Receiver
❖ DMP XR550 Control Panel
❖ DMP Graphic Touchscreen Keypad
Specifications
Operating Voltage 12 VDC
Dimensions (7800) 5.8" W × 4.13" H × 0.6" D
Dimensions (9800) 5.8" W × 4.1" H × 0.8" D
Display Type Full-color graphic LCD
Display Size 5.0" (15:9 diagonal)
Colors Gloss Black or White
Compatibility
7872/7873 XT30|XT50 and XR150|XR550 Panels
9862/9862USB XT, XTL, and XR150|XR550 Panels
Current Draw
Standby 145 mA + 1.6 mA per active zone
Alarm 215 mA + 2 mA per active zone
Standby 143 mA + 1.6 mA per active zone
Alarm 222 mA + 2 mA per active zone
Standby 120 mA + 1.6 mA per active zone
Alarm 206 mA + 2 mA per active zone
Certifications
7872/7873
California State Fire Marshal (CSFM)
FCC Part 15 RFID Reader FCC ID: CCKPC0131
Industry Canada ID: 5251A-PC0131
ETL Listed:
ANSI/UL 294 Access Control
ANSI/UL 365 Police Connected Burglar
ANSI/UL 609 Local Burglar
ANSI/UL 1023 Household Burglar
ANSI/UL 1076 Proprietary Burglar
ANSI/UL 1610 Central Station Burglar
ANSI/UL 985 Household Fire Warning
9862/9862USB
FCC Part 15: CCKPC0132
Industry Canada ID: 5251A-PC0132
ETL Listed:
ANSI/UL 1023 Household Burglar
ANSI/UL 1076 Proprietary Burglar
ANSI/UL 1610 Central Station Burglar
❖ DMP Wireless Receivers, Repeaters & Translators
Flame-retardant ABS constructed housings
1100D/1100X/1100DE/1100XE Receiver
Operating Voltage 8.0 to 14 VDC
Current Draw 35 mA
Dimensions 5.5" W × 3.75" H × 1" D
1100DH/1100XH/1100DHE/1100XHE Receiver
Operating Voltage 8.0 to 14 VDC
Current Draw 100 mA
Dimensions 5.5" W × 3.75" H × 1" D
1100DI Receiver
Operating Voltage 8.0 to 14 VDC
Current Draw 45 mA
Housing Dimensions 3.3" L × 1.6" W × 1.2" H
1100R/1100RE Repeater
Operating Voltage 8.0 to 14 VDC
Dimensions 5.5" W × 3.75" H × 1" D
1100T Translator
Operating Voltage 12 VDC, 23 mA
Standby Battery
Voltage 3.7 VDC
Capacity 800 mAh
Type Lithium Polymer, rechargeable
Standby 4 hours
Dimensions 5.50" W × 3.75" H × 1.00" D
1100TF Translator
Operating Voltage 12 VDC, 31 mA
Standby Battery
Voltage 3.7 VDC
Capacity 2400 mAh
Type Lithium Polymer, rechargeable
Standby 24 hours
Dimensions 5.50” W × 3.75” H × 1.00” D
❖ BOSCH DS7400Xi Series Addressable Control Panels
• Up to 248 zones in up to eight areas
• 400-event history buffer
• Up to 200 personal ID numbers (PINs)
• Up to 112 wireless devices
• Up to 15 keypads and/or door access control modules (DACMs)
❖ Two Independent Entry Delays
• Program zones to select from one of the two entry delay times.
• Users can select a longer entry delay time for zones located a long distance from the keypad.
❖ Easy Function Key User Interface
• Six labeled function keys eliminate the need for multi-button commands.
• Enter a PIN followed by the function key to perform functions such as arming, disarming, and resetting smoke detectors.
• The interface provides new users with easy to follow procedures.
• Expert users can quickly access items.
• A programmable Quick Arm feature allows users to turn the system on without a PIN. The system requires a PIN to turn off the system, silence alarms, or perform system tests
❖ Eight Areas
• Divide the control panel into eight separate system areas, each area with its own keypads and reporting ID. Keypads can be programmed as master keypads, allowing access to all areas.
❖ Flexible Digital Communication
• The communicator works with most alarm receivers, and supports 3/1, 4/1, 4/2, Contact ID, SIA, BFSK digital communicator formats and pager format. The pager format allows the control to dial a digital pager service and leave a numeric message representing the account number and event code
❖ Two Independent Entry Delays
• Program zones to select from one of the two entry delay times.
• Users can select a longer entry delay time for zones located a long distance from the keypad.
❖ DS7447V2 Alphanumeric Keypad
• Two lines, freely programmable display allows 16 characters of custom text to be programmed for zone and area descriptions.
• The user can adjust the sounder volume and backlight intensity using easy two-button commands.
The DS7447V2 is required for system programming.
❖ Texecom Speech dialer
• Outstanding Features
• 32 Character LCD Display •4 Voice Messages - Each up to 32 Seconds in Length
• 2 Programmable Outputs •Remote Access via Touch-tone Phone
• 4 Trigger Inputs •Upload/Download via Wintex™ Software††
• Call Acknowledgement •Context Sensitive Help
• Listen-in Mode •Passcode Protected
• Talkback Mode
• 8 Contact Numbers
• Memo Feature
• Call Abort
• Speech & Text Dialer
4 Text Messages - Each up to 32 Characters in Length
❖ Risco ProSYSTM Plus Security System
EN Security Grade Grade 3 or 2, selectable
Zones 128-512
Partitions 32
Groups per partition 4
Wireless zones 256
User codes 500
Event log 2000
Programmable outputs 6-262
Account numbers 32
Reporting formats Contact ID, SIA, SIA IP, SIA + Text
Wired keypads 48
2-Way Wireless Keypads 32 Slim Keypads
Wired or Wireless Sounders 32
Proximity key readers 64
Voice module with full menu guide - 2-way VOX for automatic switching between listen-in and speak-in
- Pre-recorded or user-recorded messages for zones, partitions, outputs
- Remote operations such as acknowledge event, arm/disarm, activate output
Zone resistance Fully selectable (2.2K default)
Housing Metal
Ethernet (IP) Plug-in modules
GSM 2G/3G Plug-in modules
PSTN Plug-in modules
❖ Risco 2-Way Wireless Multi-Function Contact (model RWX73F)
GENERAL DESCRIPTION
The RWX73F is a 2-way multi-function supervised transmitter with two separate channels that combines Magnetic/Door contact with two additional inputs (one universal and the other universal or shutter). The RWX73F has two reed switches for protection against opening doors and windows, and against any attempt to tamper with the detector using large magnets. The
RWX73F operates with RISCO Group 2-Way wireless systems.
❖ Risco Elegant Keypad Models: RPKELW, RPKELWP, RPKELB, RPKELBP
❖ Risco 2-Button Panic Keyfob
❖ Risco 2-Way Wireless Expander
Main features
Support for RISCO’s range of 2-Way wireless sounders, slim keypads, 8-button keyfobs and detectors
Up to 4 2-Way wireless slim keypads
Up to 32 supervised wireless zones (bus mode)
Up to 16 multi-function keyfobs (bus mode)
Up to 200 stand alone keyfobs (bus and stand-alone modes)
Two utility outputs
Rolling code technology
Signal jamming detection
Threshold-level calibration
Tamper detection
Transmitter supervision low battery detection
Nominal center frequency: 868.65 MHz or 433.92 MHz
Can be installed inside or outside the LightSYS main enclosure
Up to two WL Expanders per LightSYS system
C - RESIDENCES
The exact addresses and types of alarm systems will be provided upon award of the contract
Approximately 263 residences in Brussels/Antwerp need alarm systems.
Approximately 90 residences in Brussels are already equipped with alarm systems.
Approximately 163 residences in Brussels/Antwerp need yearly alarm system maintenance in
2022.
File details come from the government source that posted it. Updated .