Attachment 3 Drawings.pdf
PDF 7 MB Posted
- Attached to
- Exterior Repairs to Wooten Hall - Las Cruces, NM
- Solicitation number
- 1232SA26Q1271
About this file
This is a design document for the Las Cruces Wooton Hall Exterior Repair project located at the U.S. Department of Agriculture Agricultural Research Service facility in Las Cruces, New Mexico. The project is identified under Contract No. 12805B23D0001 and Order No. 12805B24F0142, with Asset # 623515B001.
The scope of work encompasses exterior repairs to the Wooton Hall building at New Mexico State University, including roof drainage system improvements (gutter and downspout installation), exterior wall surface preparation and painting, sealant replacement at window and door openings, sealant replacement at stone accent bands, stone coping reinstatement, clay tile roof adjustment and securing, trellis system pressure washing and painting, and interior colonnade wall surface painting. The project specifically excludes roof tile replacement from the scope. The design includes 13 sheets of construction documents encompassing building exterior outlines, roof plans with drainage details, exterior elevation views from all cardinal directions, wall section details, reference details for window and door conditions, and electrical lighting plans. Electrical work includes demolition and replacement of colonnade lighting fixtures, installation of new pole-mounted and wall-mounted LED lighting fixtures, new time clock controls for astronomical operation, and associated conduit and wiring modifications. Special precautions are required when working adjacent to a utility trench, with restrictions on loading and material stockpiling. The architectural and engineering firm Johnson M Adams Architects/Engineers is based in Greenwood, Mississippi, with design review location in Fort Collins, Colorado.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
RANGE MANAGEMENT RESEARCH
2995 KNOX STREET
LAS CRUCES, NM 88003
PROJECT LOCATION
LAS CRUCES
CONTRACT NO:12805B23D0001
AGRICULTURAL RESEARCH SERVICE
U.S. DEPARTMENT OF AGRICULTURE
RANGE MANAGEMENT RESEARCH
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
ASSET # 623515B001
LAS CRUCES, NEW MEXICO
DRAWING NO.SHEET NO. TITLE
T100
T101
A100
A101
A200
A201
A300
A301
A302
A303
E001
E100
E500
TITLE SHEET
TUNNEL CONDITION MAP
BUILDING EXTERIOR OUTLINE
ROOF PLAN
EXTERIOR ELEVATIONS
EXTERIOR ELEVATIONS
REFERENCE DETAILS
REFERENCE DETAILS
REFERENCE DETAILS
REFERENCE DETAILS
ELECTRICAL LEGEND & ABBREVIATIONS
LIGHTING PLAN
SCHEDULES AND DETAILS
NO SCALEVICINITY MAP
N
INDEX OF DRAWINGS LOCATION MAP NO SCALE
N
ORDER NO:12805B24F0142
PROJECT
LOCATION
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
TITLE SHEET
T100 1 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
USDA ARS NOTE:
ROOF TILE AREA REMOVED FROM SCOPE - SEE A101 AND A200.
jferguson
Aric.Abblitt Polygon
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
NEW MEXICO STATE UNIVERSITY
TUNNEL CONDITION MAP
T101 2 133/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
PROJECT LOCATION
CONTRACTOR SHALL TAKE PRECAUTIONS WHEN WORKING
ADJACENT TO THE UTILITY TRENCH. LIMIT LOADING OVER
TRENCH TO SINGLE AXIAL VEHICLES. NOTIFY CONTRACTING
OFFICERS REPRESENTATIVE IF TUNNEL FAILURE IS PRESENT
PRIOR TO START OF WORK. STOCKPILING OF MATERIALS
ADJACENT TO TUNNEL IS PROHIBITED.
jferguson Stamp
69'-1"
16'-4" 8'-2" 27'-3" 17'-3"
'-1
0"
'-4
'-6
'-1
'-9
204'-3"
23'-4"124'-4"8'-5"38'-10"
3'
-2
'-7
'-2
'-2
7'
-2
'-1
0" 9'
-3
9'-3"
13'-1"
'-7
'-5
'-4
5'-2"
1' -1
1"
A200
A201
A201
A200
EXISTING FACILITY OUTLINE
6' HIGH CMU BLOCK SCREEN WALLS SHALL BE
PREPPED AND PAINTED TO MATCH MAIN
STRUCTURE. TOTAL APPROXIMATE WALL
LENGTH, THIS SECTION,= 98'+/-. DO NOT PAINT
CAP STONES.
12'-0"
'-0
'-1
0"
13'-6"
'-8
'-9
6' HIGH CMU BLOCK SCREEN
WALLS SHALL BE PREPPED AND
PAINTED TO MATCH MAIN
STRUCTURE. DO NOT PAINT CAP
STONES.
6' HIGH CMU BLOCK SCREEN WALLS SHALL
BE PREPPED AND PAINTED TO MATCH MAIN
STRUCTURE. DO NOT PAINT CAP STONES.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
BUILDING EXTERIOR OUTLINE
A100 3 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
BUILDING EXTERIOR OUTLINE
1/8" = 1'-0"
A100
SPRAY APPLICATION OF PAINT IS
NOT ALLOWED.
3'-6" 1'-6"
3' -6
1'
-6
3'-6" 1'-6" 3'-6"1'-6"
3' -6
1'
-6
3' -6
1'
-6
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
REINSTALL EXISTING COPING STONE.
FACILITY PERSONNEL HAS THE
EXISTING STONE. CLEAN AND PREP
AREA AS REQUIRED TO REINSTALL
STONE.
PRESSURE WASH AND PREP METAL
TRELLIS MEMBERS TO RECEIVE PAINT.
PAINT AS SPECIFIED. CONTRACTOR
SHALL NOT APPLY ANY WEIGHT TO
TRELLIS SYSTEM.
ADJUST / SECURE EXISTING CLAY TILES
PER TRI/WSRCA CONCRETE AND CLAY
ROOF TILE INSTILLATION MANUAL,
SUBMIT PROPOSED ATTACHMENT
METHOD.
PROVIDE NEW LEADER AT EXISTING
THROUGH WALL SCUPPER.
KEYED NOTES
1 1
5' -6
5'-6"±
2 2
RE SEAL AIR TERMINAL
PENETRATION. SEE
DETAIL 4/A101.
8" ROLLED BOX GUTTER AS
SPECIFIED COLOR TO MATCH
EXISTING FASCIA TRIM
3"x4" DOWNSPOUT AS
SPECIFIED. COLOR TO MATCH
EXISTING FASCIA TRIM
DOWNSPOUT STRAP (2)
PER DOWNSPOUT MIN.
16" x 24" SHEET METAL
SPLASH PAN SET IN
BED OF MASTIC
PROVIDE GUTTER
WEDGE AT EACH END
AND MID POINT
EXISTING CLAY TILE ROOF
EXISTING FASCIA TRIM
EXISTING STUCCO FINISH
EXISTING ROOF
1'-0"
1'-0"
1' -0
PROVIDE NEW
LEADER AS
SPECIFIED
PROVIDE 4"x6"
DOWNSPOUT
AS SPECIFIED
GUTTER STRAP
2" ± TO CLEAR STONE
BAND BELOW FIELD VRIFY
EXISTING WALL
EXISTING THROUGH
WALL SCUPPER
EXISTING WALL
EXISTING THROUGH
WALL SCUPPER
PROVIDE NEW
LEADER AS
SPECIFIED
SECTION
PLAN
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
ROOF PLAN
A101 4 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
ROOF PLAN
1/8" = 1'-0"
A101
SPRAY APPLICATION OF PAINT IS
NOT ALLOWED.
SCALE:
GUTTER / DOWNSPOUT DETAIL
1" = 1'-0"
A101
2'
SCALE: 1"=1'-0"
0 1' 3'
SCALE:
LEADER DETAIL
1" = 1'-0"
A101
EXISTING AIR TERMINAL MAST
EXISTING FLASHING
REMOVE EXISTING
SEALANT, CLEAN
FLASHING AND MAST
SURFACE AND RESEAL.
SCALE:
TOWER AIR TERMINAL DETAIL
N.T.S.
A101
USDA ARS NOTE:
ROOF TILE AREA REMOVED FROM SCOPE
jferguson Stamp
LIGHT FIXTURE. TYPICAL. SEE ELECTRICAL
DRAWINGS. REPLACE OR PATCH LOOSE, CRACKED,
DAMAGED OR DEFECTIVE WORK AS DIRECTED.
PATCHING MUST MATCH EXISTING WORK IN
TEXTURE AND COLOR AND MUST BE FINISHED
FLUSH. APPROXIMATELY 1 S.F.± SEE DETAIL 3/A201.
9' -0
A.
F.
G
LIGHT FIXTURE. TYPICAL. SEE
ELECTRICAL DRAWINGS
SPRAY APPLICATION OF PAINT IS
NOT ALLOWED.
ADJUST / SECURE EXISTING CLAY TILES PER
TRI/WSRCA CONCRETE AND CLAY ROOF TILE
INSTILLATION MANUAL, SUBMIT PROPOSED
ATTACHMENT METHOD.
REINSTALL EXISTING COPING STONE.
FACILITY PERSONNEL HAS THE EXISTING
STONE. CLEAN AND PREP AREA AS
REQUIRED TO REINSTALL STONE.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
REMOVE EXISTING SEALANT COMPLETE FROM
STONE ACCENT BAND JOINTS AND ALONG TOP /
BOTTOM OF BAND. PROVIDE NEW BACKER ROD
AND SEALANT AS SPECIFIED.
REMOVE EXISTING SEALANT COMPLETE FROM STONE
ACCENT BAND JOINTS AND ALONG TOP / BOTTOM OF BAND.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED.
REMOVE EXISTING SEALANT COMPLETE FROM WINDOWS.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED
TYPICAL.
REMOVE EXISTING SEALANT COMPLETE FROM
AROUND WINDOWS. PROVIDE NEW BACKER
ROD AND SEALANT AS SPECIFIED TYPICAL.
REMOVE EXISTING SEALANT
COMPLETE FROM AROUND DOORS
PROVIDE NEW BACKER ROD AND
SEALANT AS SPECIFIED TYPICAL.
PRESSURE WASH EXISTING EXTERIOR WALL SURFACE,
INCLUDING WINDOWS, DOORS, FASCIAS, SOFFITS,
CEILINGS AND COLONNADE TRELLIS. AFTER PRESSURE
WASHING IS COMPLETE AND ALL SURFACES HAVE DRIED
TO MEET PAINT MANUFACTURERS REQUIREMENTS PAINT
SURFACES AS SPECIFIED AND INDICATED.
PRESSURE WASH EXISTING EXTERIOR WALL SURFACE, INCLUDING WINDOWS, DOORS, FASCIAS,
SOFFITS, CEILINGS AND COLONNADE TRELLIS. AFTER PRESSURE WASHING IS COMPLETE AND ALL
SURFACES HAVE DRIED TO MEET PAINT MANUFACTURERS REQUIREMENTS PAINT SURFACES AS
SPECIFIED AND INDICATED.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
PROVIDE LEADER AND 4"x6"
DOWNSPOUT AS SPECIFIED
SEE DETAIL 3/A101
1. CONTRACTOR SHALL NOTIFY C.O.R. OF ANY DISLODGED
STUCCO FINISH THAT IS ENCOUNTERED DURING WORK. IF
AREA IS ENCOUNTERED STOP WORK AT AREA UNTIL C.O.R.
HAS INSPECTED AREA AND REPAIR METHOD HAS BEEN
APPROVED.
GENERAL NOTE
REPLACE OR PATCH LOOSE, CRACKED,
DAMAGED OR DEFECTIVE WORK AS
DIRECTED. PATCHING MUST MATCH
EXISTING WORK IN TEXTURE AND COLOR
AND MUST BE FINISHED FLUSH.
APPROXIMATELY 2 S.F.± SEE DETAIL 3/A201
REMOVE EXISTING SEALANT
COMPLETE FROM AROUND DOORS
PROVIDE NEW BACKER ROD AND
SEALANT AS SPECIFIED TYPICAL.
REPLACE OR PATCH LOOSE,
CRACKED, DAMAGED OR DEFECTIVE
WORK AS DIRECTED. PATCHING MUST
MATCH EXISTING WORK IN TEXTURE
AND COLOR AND MUST BE FINISHED
FLUSH. APPROXIMATELY 2 S.F.± SEE
DETAIL 3/A201
REPLACE OR PATCH LOOSE,
CRACKED, DAMAGED OR DEFECTIVE
WORK AS DIRECTED. PATCHING MUST
MATCH EXISTING WORK IN TEXTURE
AND COLOR AND MUST BE FINISHED
FLUSH. APPROXIMATELY 2 S.F.± SEE
DETAIL 3/A201
REMOVE EXISTING SEALANT COMPLETE FROM STONE
ACCENT BAND JOINTS AND ALONG TOP / BOTTOM OF BAND.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED.
REMOVE EXISTING SEALANT COMPLETE FROM STONE
ACCENT BAND JOINTS AND ALONG TOP / BOTTOM OF BAND.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED.
REMOVE EXISTING SEALANT COMPLETE FROM
AROUND WINDOWS. PROVIDE NEW BACKER
ROD AND SEALANT AS SPECIFIED TYPICAL.
LIGHT FIXTURE. TYPICAL. SEE
ELECTRICAL DRAWINGS
PAINT INTERIOR FACE OF
WALL AT COLONNADE AS
SPECIFIED.
LIGHT FIXTURE. TYPICAL. SEE
ELECTRICAL DRAWINGS
PAINT INTERIOR FACE OF WALL AT
COLONNADE AS SPECIFIED.
PAINT INTERIOR FACE OF WALL AT
COLONNADE AS SPECIFIED.
PAINT INTERIOR FACE OF WALL
AT COLONNADE AS SPECIFIED.
DOOR / WINDOW
PAINT SCHEDULE
ALUMINUM
WINDOWS
NO WINDOWS ARE
TO BE PAINTED.
ALUMINUM
DOORS
NO ALUMINUM STORE
FRONT TYPE DOORS
ARE TO BE PAINTED
HOLLOW
METAL
DOORS
PAINT AS SPECIFIED
(3) DOORS INDICATED
ON ELEVATIONS.
PAINT HOLLOW METAL DOORS
AND FRAMES AS SPECIFIED.
PREP AND PAINT EXISTING ROOF
ACCESS LADDER AS SPECIFIED COLOR
TO MATCH EXISTING WALL SURFACE .
PREP AND PAINT EXISTING 2"± GAS PIPE
AS SPECIFIED COLOR TO MATCH
EXISTING WALL SURFACE .
PREP AND PAINT EXISTING ROOF
ACCESS LADDER AS SPECIFIED COLOR
TO MATCH EXISTING WALL SURFACE .
REINSTALL EXISTING COPING STONE.
FACILITY PERSONNEL HAS THE EXISTING
STONE. CLEAN AND PREP AREA AS
REQUIRED TO REINSTALL STONE.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
EXTERIOR ELEVATIONS
A200 5 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
SOUTH ELEVATION
1/8" = 1'-0"
A200
SCALE:
NORTH ELEVATION
1/8" = 1'-0"
A200
USDA ARS NOTE:
ROOF TILE AREA REMOVED FROM SCOPE
jferguson
SPRAY APPLICATION OF PAINT IS
NOT ALLOWED.
LIGHT FIXTURE. TYPICAL. SEE ELECTRICAL DRAWINGS.
REPLACE OR PATCH LOOSE, CRACKED, DAMAGED OR
DEFECTIVE WORK AS DIRECTED. PATCHING MUST MATCH
EXISTING WORK IN TEXTURE AND COLOR AND MUST BE
FINISHED FLUSH. APPROXIMATELY 1 S.F.±
9'
-0
A.
F.
G
LIGHT FIXTURE. TYPICAL. SEE
ELECTRICAL DRAWINGS
1. CONTRACTOR SHALL NOTIFY C.O.R. OF ANY DISLODGED
STUCCO FINISH THAT IS ENCOUNTERED DURING WORK. IF
AREA IS ENCOUNTERED STOP WORK AT AREA UNTIL C.O.R.
HAS INSPECTED AREA AND REPAIR METHOD HAS BEEN
APPROVED.
GENERAL NOTE
REMOVE EXISTING SEALANT COMPLETE FROM STONE
ACCENT BAND JOINTS AND ALONG TOP / BOTTOM OF BAND.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED.
REMOVE EXISTING SEALANT COMPLETE FROM STONE
ACCENT BAND JOINTS AND ALONG TOP / BOTTOM OF BAND.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101. PROVIDE 5' LONG SECTION OF GUTTER
WITH DOWNSPOUT SEE DETAIL 2/A101.
REPLACE OR PATCH LOOSE, CRACKED, DAMAGED OR
DEFECTIVE WORK AS DIRECTED. PATCHING MUST MATCH
EXISTING WORK IN TEXTURE AND COLOR AND MUST BE
FINISHED FLUSH. APPROXIMATELY 2 S.F.± SEE DETAIL 3/A201
PRESSURE WASH EXISTING EXTERIOR WALL SURFACE, INCLUDING WINDOWS, DOORS, FASCIAS,
SOFFITS, CEILINGS AND COLONNADE TRELLIS. AFTER PRESSURE WASHING IS COMPLETE AND ALL
SURFACES HAVE DRIED TO MEET PAINT MANUFACTURERS REQUIREMENTS PAINT SURFACES AS
SPECIFIED AND INDICATED.
PRESSURE WASH EXISTING EXTERIOR WALL SURFACE, INCLUDING WINDOWS, DOORS, FASCIAS,
SOFFITS, CEILINGS AND COLONNADE TRELLIS. AFTER PRESSURE WASHING IS COMPLETE AND ALL
SURFACES HAVE DRIED TO MEET PAINT MANUFACTURERS REQUIREMENTS PAINT SURFACES AS
SPECIFIED AND INDICATED.
REMOVE EXISTING SEALANT
COMPLETE FROM AROUND DOORS
PROVIDE NEW BACKER ROD AND
SEALANT AS SPECIFIED TYPICAL.
9' -0
A.
F.
G
LIGHT FIXTURE.
TYPICAL. SEE
ELECTRICAL DRAWINGS
REMOVE EXISTING SEALANT COMPLETE
FROM WINDOWS. PROVIDE NEW BACKER
ROD AND SEALANT AS SPECIFIED TYPICAL.
REMOVE EXISTING SEALANT COMPLETE
FROM WINDOWS. PROVIDE NEW BACKER
ROD AND SEALANT AS SPECIFIED TYPICAL.
REMOVE EXISTING SEALANT COMPLETE FROM STONE
ACCENT BAND JOINTS AND ALONG TOP / BOTTOM OF BAND.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED.
REMOVE EXISTING SEALANT COMPLETE FROM STONE
ACCENT BAND JOINTS AND ALONG TOP / BOTTOM OF BAND.
PROVIDE NEW BACKER ROD AND SEALANT AS SPECIFIED.
PAINT INTERIOR FACE OF WALL AT
COLONNADE AS SPECIFIED.
PAINT INTERIOR FACE OF WALL AT
COLONNADE AS SPECIFIED.
PAINT INTERIOR FACE OF WALL AT
COLONNADE AS SPECIFIED.
LIGHT FIXTURE. TYPICAL. SEE
ELECTRICAL DRAWINGS
PAINT INTERIOR FACE OF
WALL AT COLONNADE AS
SPECIFIED.
DOOR / WINDOW
PAINT SCHEDULE
ALUMINUM
WINDOWS
NO WINDOWS ARE
TO BE PAINTED.
ALUMINUM
DOORS
NO ALUMINUM STORE
FRONT TYPE DOORS
ARE TO BE PAINTED
HOLLOW
METAL
DOORS
PAINT AS SPECIFIED
(3) DOORS INDICATED
ON ELEVATIONS.
PAINT HOLLOW METAL DOORS
AND FRAMES AS SPECIFIED.
PREP AND PAINT EXISTING ROOF
ACCESS LADDER AS SPECIFIED COLOR
TO MATCH EXISTING WALL SURFACE .PREP AND PAINT EXISTING ROOF
ACCESS LADDER AS SPECIFIED COLOR
TO MATCH EXISTING WALL SURFACE .
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
EXTERIOR ELEVATIONS
A201 6 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
WEST ELEVATION
1/8" = 1'-0"
A201
SCALE:
EAST ELEVATION
1/8" = 1'-0"
A201
EXISTING FRAMING
EXISTING WEATHER BARRIER
FINISH COAT
BROWN COAT
SCRATCH COAT
METAL LATH
WEEP ACCESSORY
SCALE:
GENERAL STUCCO DETAIL
N.T.S.
A201
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
REFERENCE DETAILS
A300 7 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
REFERENCE DETAILS
A301 8 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
REFERENCE DETAILS
A302 9 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
REFERENCE DETAILS
A303 10 1303/19/2025
REH
JLF
DRL 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
ABBR.
AMPERE(S)
DESCRIPTION
A / AMP
ALTERNATING CURRENT : AIR COMPRESSOR
AIR CURTAIN : ABOVE COUNTER/ BACKSPLASH
AMPERE FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE INTERRUPT CAPACITY
ALUMINUM
AMP TRIP
AUTOMATIC TRANSFER SWITCH
AUTOMATIC
AIR COOLED CONDENSING UNITACCU
AC
AC
AF
AFF
AFG
AHU
AIC
AL
AT
ATS
AUTO
AUX
AWG
BRKR
BLDG
C
CAT
CB
CCT
CCTV
CFCI
CKT
CLG
CMH
COMM
CP
CPT
CRI
CT
CU
AUXILIARY
BREAKER
BUILDING
CONDUIT
CATEGORY
CIRCUIT BREAKER
CORRELATED COLOR TEMPERATURE
CLOSED CIRCUIT TELEVISION
CONTRACTOR FURNISHED/ INSTALLED
CIRCUIT
CEILING
COMMUNICATIONS MANHOLE
AMERICAN WIRE GUAGE
COMMUNICATIONS
CONTROL POWER TRANSFORMER
COLOR RENDERING INDEX
CURRENT TRANSFORMER : COOLING TOWER
COPPER : CONDENSING UNIT
CONDENSATE PUMP
HEIGHT
HORSE POWER : HEAT PUMP
INTERMEDIATE METAL CONDUIT
KILO
THOUSAND AMPERE INTERRUPT CAPACITY
THOUSANDS OF CIRCULAR MILS
KILOVOLT
KILOVOLT-AMPERES
KILOWATT
KILOWATT - HOUR
LENGTH
LOCAL AREA NETWORK
HAND-OFF AUTOMATICHOA
HP
IMC
K
KAIC
KCMIL
KV
KVA
KW
KWHR
L
LAN
LTG
MAX
MCA
MCB
MCC
MGB
MH
MIN
MLO
NEC
NEMA
NFPA
NC
NESC
NL
NO
NTS
LIGHTING
MINIMUM CIRCUIT AMPACITY
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAIN GROUND BAR
MANHOLE / MOUNTING HEIGHT
MINIMUM
MAIN LUGS ONLY
NATIONAL ELEC CODE
NATIONAL ELEC MANUFACTURER'S ASSOCIATION
NATIONAL FIRE PROTECTION ASSOCIATION
MAXIMUM
NORMALLY CLOSED
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALE
NATIONAL ELEC SAFETY CODE
ABBR. DESCRIPTION
D
DC
DISC
DIST
DPST
DPDT
EC
EF
ELEC
EMER
EMH
EMT
EPA
EQUIP
DEPTH
DIRECT CURRENT
DISCONNECT
DISTRIBUTION
DOUBLE POLE SINGLE THROW
DOUBLE POLE DOUBLE THROW
EMPTY CONDUIT
EXHAUST FAN
ELECTRICAL
ELECTRICAL MANHOLE
ELECTRICAL METALLIC TUBING
EFFECTIVE PROJECTED AREA
EQUIPMENT
EMERGENCY
PF
PH
PNL
PTAC
PVC
REC / RECPT
RMC
RTU
RVNR
SA
SCCR
SF
SPD
POWER FACTOR
PHASE
PANEL : PANELBOARD
PACKAGED THRU-WALL AIR CONDITIONER
POLYVINYL CHLORIDE
RECEPTACLE
RIGID METAL CONDUIT
ROOF TOP UNIT
REDUCED VOLTAGE NON-REVERSING
SHORT CIRCUIT CURRENT RATING
SUPPLY FAN
SURGE PROTECTIVE DEVICE
SURGE ARRESTORS
EX / EXIST
EUH
EXP
EWH / EWC
EXISTING
EXPLOSION PROOF
ELECTRIC WATER HEATER / COOLER
ELECTRIC UNIT HEATER
SPEC
SPST
SWBD
SWGR
SPECIFICATIONS
SWITCHBOARD
SINGLE POLE SINGLE THROW
F
FACP
FCU
FLEX
G / GND
GFGI
GFI / GFCI
GRS
GUH
GWH
FUSE
FIRE ALARM CONTROL PANEL
FAN COIL UNIT
FLEXIBLE
GROUND
GOVERNMENT FURNISHED / INSTALLED
GROUND FAULT (CIRCUIT) INTERRUPTER
GALVANIZED RIGID STEEL
GAS UNIT HEATER
GAS WATER HEATER
TMGB
TOL
TYP
UH
UOI
UL
W
WP
Z
TELECOMMUNICATION MAIN GROUNDING BUSBAR
THERMAL OVERLOAD
TYPICAL
UNIT HEATER
UNLESS OTHERWISE INDICATED
UNDERWRITERS LABORATORY
WATTS : WIDTH
WEATHERPROOF
IMPEDANCE
P POLE(S)
SPDT SINGLE POLE DOUBLE THROW
SWITCHGEAR
H / HT
NAT NATIONAL
XFMR TRANSFORMER
ETC. ETCETERA
MTD MOUNTED
N NEUTRAL
QTY QUANTITY
ABBREVIATIONS
ABBREVIATIONS ABOVE ARE FOR ELECTRICAL
SHEETS ONLY. NOT ALL MAY BE USED.
MGC MAIN GROUNDING CONDUCTOR
1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE
DRAWINGS ARE NOT INTENDED TO INDICATE OR DESCRIBE ALL WORK
REQUIRED FOR THE FULL PERFORMANCE AND COMPLETION OF THE
REQUIREMENTS OF THE CONTRACT.
2. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL
PARTS OF THE WORK SO THAT NO WORK SHALL BE LEFT IN AN
UNFINISHED OR INCOMPLETE CONDITION. INSTALLATION OF
ELECTRICAL WORK SHALL BE COORDINATED WITH OTHER TRADES
BEFORE ANY INSTALLATION IS DONE. CONDUIT AND DEVICES SHOWN
ON PLANS ARE SCHEMATIC.
3. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND
MANUFACTURER'S PUBLISHED STANDARDS FOR QUALITY OF
MATERIALS AND WORKMANSHIP, AS WELL AS, ALL REQUIREMENTS IN
THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING
REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT
TO THE CONTACTING OFFICER'S ATTENTION PRIOR TO PROCEEDING
WITH THE WORK.
4. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND NEW
WORK.
5. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
SHALL VERIFY ALL NEW AND EXISTING CONDITIONS SHOWN ON THESE
DRAWINGS. THE CONTRACTOR SHALL NOTIFY THE C.O. IN WRITING OF
ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.
6. THE CONTRACTOR SHALL PLAN WORK TO PROVIDE ADEQUATE
PROTECTION FOR PERSONS AND PROPERTY AT ALL TIMES, AND
EXECUTE THE WORK IN SUCH A MANNER TO AVOID ANY HAZARD TO
PERSONS AND PROPERTY AS NECESSARY.
7. MINIMUM RACEWAY SIZE SHALL BE 3/4-IN. INCREASE RACEWAY SIZE AS
REQUIRED TO LIMIT RACEWAY FILL RATIO TO LESS THAN 40% FULL.
8. ALL CONDUCTORS SHALL BE COPPER.
9. ALL FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE A GREEN
INSULATED GROUND CONDUCTOR, SIZE PER NATIONAL ELECTRICAL
CODE, OR AS SHOWN, CONNECTED TO EACH DEVICE AND OUTLET BOX
ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS. PROVIDE A
DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT.
MULTIPLE BRANCH CIRCUITS IN ONE RACEWAY REQUIRE ONLY ONE
GROUND CONDUCTOR.
10. ALL SAFETY DISCONNECTS SHALL BE HEAVY DUTY 240V NEMA 3R
NON-FUSED TYPE.
11. NEW WORK SHALL BE MADE TO TIE INTO THE EXISTING IN A UNIFORM
MANNER, SIMILAR ITEMS OF NEW WORK SHALL BE CHECKED AGAINST
EXISTING WORK.
12. REFER TO ONE-LINE DIAGRAMS, SCHEDULES, AND TABLES FOR
CONDUCTOR AND CONDUIT SIZES NOT SHOWN ON PLANS.
13. PROVIDE LABELS ON ALL RECEPTACLES, WALL MOUNTED LIGHT
SWITCHES/OCCUPANCY SENSORS AND JUNCTION BOXES INDICATING
THE SOURCE PANEL AND CIRCUIT(S). TEXT SHALL BE BLACK 1/4-IN IN
HEIGHT PRINTED ON A CLEAR LABEL. HANDWRITTEN LABELS ARE NOT
PERMITTED.
14. COORDINATE WALL, FLOOR AND ROOF PENETRATIONS WITH THE
OWNER'S REPRESENTATIVE.
15. SUPPLEMENTAL STEEL MEMBERS REQUIRED TO SUPPORT ELECTRICAL
EQUIPMENT FROM MAIN STRUCTURE SHALL BE PROVIDED BY THE
ELECTRICAL CONTRACTOR UNLESS SPECIFICALLY NOTED OTHERWISE.
16. EXACT LOCATIONS OF PANELBOARDS, DISCONNECTS, TIMERS, AND
SWITCHES SHALL BE COORDINATED WITH FINAL LOCATIONS OF
WALL-MOUNTED ARCHITECTURAL AND MECHANICAL EQUIPMENT.
MOUNT DISCONNECTS AND SWITCHES MINIMUM 48" AFF. MOUNT
TIMERS MINIMUM 40" AFF.
17. SPECIFICATIONS TAKE PRECEDENCE OVER DRAWINGS. HOWEVER,
ITEMS SHOWN ON DRAWING BUT NOT IN THE SPECIFICATIONS ARE
REQUIRED WITHIN THE PROJECT SCOPE. IN ADDITION, SPECIFIC
ITEMS SHOWN ON THE DRAWINGS TAKE PRECEDENCE OVER
SPECIFICATIONS IN CASES WHERE THE SPECIFICATION HAS
OPTIONS.
18. ALL EQUIPMENT INSTALLED IN THIS PROJECT SHALL COMPLY WITH
THE "BUY AMERICAN ACT". BASIS OF DESIGN SHOWN ON
SCHEDULES IS TO ESTABLISH A STANDARD OF QUALITY, NOT TO
LIMIT COMPETITION. EQUIVALENT EQUIPMENT FROM ANOTHER
MANUFACTURER IS ACCEPTABLE.
19. PROVIDE WEATHERPROOF COVERS FOR ALL SWITCHES.
20. THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL,
MECHANICAL, CIVIL DRAWINGS AND SPECIFICATIONS FOR EXACT
LOCATION OF EQUIPMENT. ALL WORK SHALL BE COORDINATED WITH
THE WORK OF OTHER TRADES TO AVOID INTERFERENCE. REFER TO
MECHANICAL DRAWINGS FOR PIPES, DUCTS, AND MECHANICAL
EQUIPMENT.
GENERAL PROJECT NOTES:
SYMBOL / KEY
REVISION TAG DESIGNATION
DESCRIPTION
TOP DESIGNATION IS SECTION DESIGNATION
KEY NOTE DESIGNATION
BOTTOM DESIGNATION IS SECTION SHEET LOCATION (STANDARD SYMBOL SCALED DOWN FOR LEGEND)
NOTE: ANY CIRCUIT WITHOUT FURTHER DESIGNATION INDICATES A 2 WIRE #12AWG CIRCUIT WITH A #12AWG
GND. A GREATER NUMBER OF WIRES IS INDICATED AS FOLLOWS:
4 WIRE, 2 CIRCUITS & GROUND (LONGER SLASH INDICATES NEUTRAL)
6 WIRE, 3 CIRCUITS & GROUND, ETC.(WIRING LARGER THAN #10AWG SHALL BE AS NOTED)
INDICATES #10 GROUND CONDUCTOR UOI (DOUBLE TICK/SLASH INDICATES ISOLATED GROUND)
PANELBOARD AND CIRCUIT DESIGNATION
RACEWAY CONCEALED IN WALL OR CEILING OR EXPOSED ON STRUCTURE AS REQUIRED
HOMERUN TO PANELBOARD - LETTERS INDICATE PANEL, NUMBERS INDICATE CIRCUIT
(NOT ALL SYMBOLS MAY APPLY, TYP.)
TAG STYLE ANNOTATION: CIRCUIT DESIGNATION, POINT TOWARD ASSOCIATED BRANCH/DIST PANEL.
TAG STYLE ANNOTATION: ELEC EQUIP DESIGNATION (PANELBOARDS, XFMRS, DIST BOARDS, ETC.)
TAG STYLE ANNOTATION: ELECTRICALLY POWERED EQUIPMENT (PROVIDED BY OTHERS)
TAG STYLE ANNOTATION: ELECTRICALLY POWERED MECHANICAL/PLUMBING EQUIPMENT (RE: MECHANICAL)
TOP DESIGNATION IS PLAN / ENLARGED PLAN / DETAIL NUMBER
BOTTOM DESIGNATION IS SHEET LOCATION (STANDARD SYMBOL SCALED DOWN FOR LEGEND)
LA1:13
LA1:13
EP101
A
EP101
GENERAL SYMBOLS LEGEND
CIRCUITRY RUN IN STRAIGHT LINE SEGMENTS SIGNIFIES EXPOSED
SURFACE-MOUNTED RACEWAY (SEE SPECIFICATIONS).
SYMBOL / KEY
LIGHT FIXTURE, RECESSED,
PENDANT OR SURFACE MTD.
DESCRIPTION SYMBOL / KEY DESCRIPTION
LIGHT FIXTURE, STRIP LUMINARE,
RECESSED, PENDANT, OR SURFACE MTD.
LIGHT FIXTURE, RECESSED TYPE
DOWLIGHT. DIRECTIONAL AS INDICATED.
LIGHT FIXTURE, PENDANT OR
SURFACE MTD.
LIGHT FIXTURE, WALL MTD.
EXIT LUMINAIRE, WALL OR CEILING MTD.
ARROWS INDICATE DIRECTION, SHADING
INDICATES LIGHTED FACES
EMERGENCY FLOODLIGHT W/
BATTERY BACKUP
EMERGENCY FLOODLIGHT REMOTE HEAD
LIGHT TRACK, NUMBER OF
LUMINAIRES AS SHOWN.
LUMINAIRE CONNECTED TO EMERGENCY
CIRCUIT. TO INCLUDE BATTERY BACK-UP,
GENERATOR, INVERTER, ETC. SEE PLANS
UPPERCASE LETTER INDICATES
LUMINAIRE TYPE, LOWERCASE LETTER
INDICATES CONTROLS/ SWITCH SYSTEM.
POLE MOUNTED LIGHT FIXTURE.
NUMBER OF HEADS AS INDICATED.
S A,a a
TIME CLOCKTC
VACANCY SENSORVS
OCCUPANCY SENSOROS
PHOTOELECTRIC SWITCHPES
S* SWITCH (* = TYPE)
S S2
SINGLE POLE SWITCH
DOUBLE POLE
THREE WAY
TIMER SWITCH
WALL BOX VACANCY SENSOR
WALL BOX OCCUPANCY SENSOR
DIMMER
S3 S T S S S
VS
OS
D C LOCAL CONTACTOR
SWITCH W/ THERMAL OVERLOAD
SERVING MOTORSTO
LOWERCASE LETTER INDICATES
EQUIPMENT CONTROLLED
Sa
LIGHTING AND SWITCHING LEGEND
ETR EXISTING TO REMAIN
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
ELECTRICAL LEGEND & ABBREVIATIONS
E001 11 1303/19/2025
REH
DRL
JGM 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
SYMBOL / KEY DESCRIPTION
PANELBOARD (PLAN VIEW)
ONE-LINE DIAGRAM, SCHEDULE, AND
DISTRIBUTION LEGEND
H
B
C
C
C
D
D
D
E1
E2
GENERAL NOTES
1. REFER TO E001 FOR GENERAL NOTES AND SYMBOLS LIST.
2. CONTRACTOR MUST IDENTIFY AND CONFIRM THE CONTENTS OF
PANELS EH1A, H1A, AND L1A BEFORE BEGINNING WORK.
EX HANDHOLE
B
A
A A A
A A A A A A
A A A A A A
EH1A-41
AAAA
A
A
A
A
AA
EH1A-39
A
A
A
A
A
H1AEH1A
EH1A:37
EH1A:35
EH1A:35
A
EH1A:37
EH1A:37
EH1A:37
E1
L1A
EH1A-2
EH1A-1
EX
TIME CLOCK
EX
CONTACTS
DEMOLISH FIXTURE. CAP WIRES AND REPLACE FIXTURE WITH A
PLATE COVER.
EXISTING LIGHTING CONTROLS ARE CURRENTLY POWERED
FROM L1A. DEMO BACK TO L1A.
REPLACE EXISTING CONTACTS WITH NEW CONTACTS.
PROVIDE A NEW ASTRONOMICAL TIME CLOCK POWERED BY
EXISTING SPARE, EH1A:33. TIME CLOCK IS TO OPERATE ON
120/277VAC. ASTRONOMICAL TIME CLOCK CONTROL: PROGRAM
ON, PROGRAM OFF, PROVIDE HAND/OFF/AUTO SWITCH.
ALL FIXTURES THAT ARE FIXTURE "A" SHALL REPLACE EXISTING
COLONNADE FIXTURES. THE FIXTURES SHALL BE MOUNTED AT
THE SAME PLACE AS THE EXISTING FIXTURES. USE EXISTING
CONDUIT AND WIRE TO RELOCATE INDIVIDUAL CIRCUITS
H1A:7,9,11 TO EXISTING SPARE, EH1A:37,39,41.
ALL FIXTURES THAT ARE FIXTURE "B" SHALL BE POLE
MOUNTED. THE POLE SHALL BE 12' AFG. POWER SHALL BE
SUPPLIED BY THE EXISTING HANDHOLE. THE POWER IS
CURRENTLY 120/208V. INDIVIDUAL CIRCUITS WILL BE CHANGED
TO 277V AND RELOCATED FROM INDIVIDUAL CIRCUITS L1A:28,30
TO EXISTING SPARES, EH1A:33,35. THE WIRES, FROM THE TIME
CLOCK TO FIELD DEVICES, WILL BE THE WRONG COLOR FOR
THE VOLTAGE. THEY SHALL HAVE ENDS TAPED WITH THE
APPROPRIATE COLOR/LABELING. DEMOLISH CIRCUIT BACK TO
L1A.
ALL FIXTURES THAT ARE FIXTURE "C" SHALL BE POLE MOUNTED
AND REPLACE THE EXISTING SPOT LIGHT. THE EXISTING
FEEDER SHALL BE MOVED TO THE CENTER OF THE RAISED
FLOWER BED. THE POLE SHALL BE 18' AFG IN THE CENTER OF
THE RAISED FLOWER BED. THE POLE SHALL HAVE THREE 6'
ARMS SPACED 120 DEGREES. USE EXISTING CONDUIT AND
WIRE TO RELOCATE INDIVIDUAL CIRCUITS H1A:7,9,11 TO
EXISTING SPARE, EH1A:37,39,41.
ALL FIXTURES THAT ARE FIXTURE "D" SHALL REPLACE EXISTING
WALL PACKS. THE FIXTURES SHALL MOUNTED AT THE SAME
PLACE AS THE EXISTING FIXTURES. USE EXISTING CONDUIT
AND WIRE TO RELOCATE INDIVIDUAL CIRCUITS H1A:7,9,11 TO
EXISTING SPARE, EH1A:37,39,41.
FIXTURES "E1" AND "E2" SHALL BE MOUNTED IN EXISTING
OVERHANGS. POWER SHALL BE SUPPLIED BY EXISTING
INTERIOR CIRCUITS.
KEYED NOTES
EH1A:37
EX
EX
EX
EX
EX
NEW
TIME CLOCK
NEW
CONTACTS
0 16'8'4' 24'
SCALE: 1/8"= 1'-0"
SCALE:
COLONNADE PLAN
1/8" = 1'-0"
E100
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
LIGHTING PLAN
E100 12 1303/19/2025
REH
DRL
JGM 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM WITH INTEGRAL PASSIVE COOLING MECHANISM.
HEAT SINK MUST BE INCORPORATED DIRECTLY INTO HOUSING OR DRIVER
COMPARTMENT TO ENSURE MAXIMUM HEAT TRANSFER AND DISSIPATION.
2. FINISH - MULTI-STAGE PRE-TREATMENT, FINISHED WITH BAKED-ON POLYESTER
POWDER COAT. IP66 RATED.
3. POWER SUPPLY/LED DRIVER - CLASS 1 DRIVER MUST OPERATE AT 120/277 VOLTS,
50/60 HZ, POWER FACTOR GREATER THAN 0.9 AND THD LESS THAN 20% AT
FULL LOAD. MINIMUM EFFICACY MUST BE 60 LM/W AT MAXIMUM 600mA OPERATING
CURRRENT.
4. LED OPTICAL ASSEMBLY - PRECISION MOLDED ACRYLIC LENS PROVIDED FOR
MULTIPLE HIGH-POWERED LEDS. BUG UPLIGHT RATING OF U0. MINIMUM COLOR
RENDERING INDEX(CRI) MUST BE 80 FOR
3500K.
CORRELATED COLOR TEMPERATURE OF
5. CERTIFICATION - UL AND/OR ETL LISTED FOR DAMP OR WET LOCATIONS (FOR
EXTERIOR WALL MOUNT) AND ROHS COMPLIANT.
6. OPTIONS - VARIOUS LUMEN OUTPUT RATINGS AS INDICATED.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LED WALL MOUNTED FIXTURE
FIXTURE TYPE: A
LUMINAIRE REQUIREMENTS:
1. HOUSING - SINGLE-PIECE-DIE-CAST ALUMINUM HOUSING WITH NOMINAL WALL
THICKNESS OF .012''. DIE-CAST TOP ACESS DOORFRAME HAS IMPACT RESISTANT,
TEMPERED GLASS LENS (3/16 '' THICK). DOORFRAME IS FULLY GASKETED WITH
ONE-PIECE TUBLAR SILICONE.
2. FINISH - EXTERIOIR PARTS ARE PROTECTED BY A ZINC-INFUSED SUPER DURABLE
TGIC THERMOSET POWDER COAT FINISH THAT PROVIDES SUPERIOR
RESTISTANCE TO CORROSION AND WEATHERING. FINISH IS DARK BRONZE.
3. POWER SUPPLY/LED DRIVER - CLASS 1 ELECTRONIC DRIVER HAS A POWER
FACTOR >90%, THD <20%, AND HAS AN EXPECTED LIFE OF 100,000 HOURS WITH
<1% FAILURE RATE. EASILY-SERVICEABLE SURGE PROTECTION DEVICE MEETS A
MINIMUM CATEGORY C LOW FOR OPERATION (PER ANSI/IEEE C62.41.2).
4. LED OPTICAL ASSEMBLY - PRECISION ACRYLIC REFRACTIVE OPTICS FOR
OPTIMUM LIGHT DISTRIBUTION THROUGH THE FLAT GLASS LENS. CORRELATED
COLOR TEMPERATURE SHOULD BE AS SCHEDULED. MINIMUM 80 CRI CCT.
5. CERTIFICATION - CSA CERTIFIED TO U.S. AND CANADIAN STANDARDS. LUMINAIRE
IS IP65 RATED. RATED FOR -40 DEGREES CELSIUS MINIMUM AMBIENT.
6. OPTIONS - VARIOUS LUMEN OUTPUT RATINGS AS INDICATED.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
POLE MOUNTED PATH LIGHT
FIXTURE TYPE: B
LED WALL MOUNTED FIXTURE
FIXTURE TYPE: C
LUMINAIRE REQUIREMENTS:
1. HOUSING - DIE-CAST ALUMINUM WITH INTEGRAL PASSIVE COOLING MECHANISM.
HEAT SINK MUST BE INCORPORATED DIRECTLY INTO HOUSING OR DRIVER
COMPARTMENT TO ENSURE MAXIMUM HEAT TRANSFER AND DISSIPATION.
2. FINISH - MULTI-STAGE PRE-TREATMENT, FINISHED WITH BAKED-ON POLYESTER
POWDER COAT. IP66 RATED. FINISH IS DARK BRONZE.
3. POWER SUPPLY/LED DRIVER - CLASS 1 DRIVER MUST OPERATE AT 120/277 VOLTS,
50/60 HZ, POWER FACTOR GREATER THAN 0.9 AND THD LESS THAN 20% AT
FULL LOAD. MINIMUM EFFICACY MUST BE 60 LM/W AT MAXIMUM 600mA OPERATING
CURRRENT.
4. LED OPTICAL ASSEMBLY - PRECISION MOLDED ACRYLIC LENS PROVIDED FOR
MULTIPLE HIGH-POWERED LEDS. BUG UPLIGHT RATING OF U0. MINIMUM COLOR
RENDERING INDEX(CRI) MUST BE 80 FOR
4000K.
CORRELATED COLOR TEMPERATURE OF
5. CERTIFICATION - UL AND/OR ETL LISTED FOR DAMP OR WET LOCATIONS (FOR
EXTERIOR WALL MOUNT) AND R0HS COMPLIANT.
6. OPTIONS - VARIOUS LUMEN OUTPUT RATINGS AS INDICATED.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
LED WALL MOUNTED FIXTURE
FIXTURE TYPE: D
LUMINAIRE REQUIREMENTS:
1. HOUSING - GALVANIZED STEEL MOUNTING/PLASTER FRAME. GALVANIZED STEEL
JUNCTION BOX WITH THE BOTTOM HINGED COVERS AND SPRING LATCHES.
REFLECTOR RETAINED BY TORSION SPRINGS.
2. LIGHT SOURCE - COLOR TEMPERATURE AS SCHEDULED, EFFICACY OF 91
LUMENS/ WATT, WITH A MINIMUM CRI OF 90.
3. DRIVER - OPERATING VOLTAGE OF 120/277V.
4. CERTIFICATION - UL 1598, DLC QUALIFIED, AND ROHS COMPLIANT. COMPLIES
WITH LM79, LM80 AND TM21 TESTING STANDARDS. UL 924 WHEN EQUIPPED WITH
EMERGENCY BATTERY BACK-UP. IC RATED WHEN INDICATED.
5. MOUNTING - RECESSED IN SUSPENDED ACOUSTICAL TILE OR HARD CEILING.
6. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A
LUMINAIRE THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT
INTENDED TO INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
6'' LED RECESSED DOWNLIGHT
FIXTURE TYPE: E1, E2
LUMINAIRE REQUIREMENTS:
1. HOUSING - SINGLE-PIECE-DIE-CAST ALUMINUM HOUSING WITH NOMINAL WALL
THICKNESS OF .012''. DIE-CAST TOP ACESS DOORFRAME HAS IMPACT RESISTANT,
TEMPERED GLASS LENS (3/16 '' THICK). DOORFRAME IS FULLY GASKETED WITH
ONE-PIECE TUBLAR SILICONE.
2. FINISH - EXTERIOIR PARTS ARE PROTECTED BY A ZINC-INFUSED SUPER DURABLE
TGIC THERMOSET POWDER COAT FINISH THAT PROVIDES SUPERIOR
RESTISTANCE TO CORROSION AND WEATHERING. FINISH IS DARK BRONZE.
3. POWER SUPPLY/LED DRIVER - CLASS 1 ELECTRONIC DRIVER HAS A POWER
FACTOR >90%, THD <20%, AND HAS AN EXPECTED LIFE OF 100,000 HOURS WITH
<1% FAILURE RATE. EASILY-SERVICEABLE SURGE PROTECTION DEVICE MEETS A
MINIMUM CATEGORY C LOW FOR OPERATION (PER ANSI/IEEE C62.41.2).
4. LED OPTICAL ASSEMBLY - PRECISION ACRYLIC REFRACTIVE OPTICS FOR
OPTIMUM LIGHT DISTRIBUTION THROUGH THE FLAT GLASS LENS. CORRELATED
COLOR TEMPERATURE SHOULD BE AS SCHEDULED. MINIMUM 80 CRI CCT.
5. CERTIFICATION - CSA CERTIFIED TO U.S. AND CANADIAN STANDARDS. LUMINAIRE
IS IP65 RATED. RATED FOR -40 DEGREES CELSIUS MINIMUM AMBIENT.
6. OPTIONS - VARIOUS LUMEN OUTPUT RATINGS AS INDICATED.
7. THIS SKETCH IS A NON-PROPRIETARY GRAPHIC REPRESENTATION OF A LUMINAIRE
THAT MAY MEET THE SPECIFICATION REQUIREMENTS. IT IS NOT INTENDED TO
INDICATE A CERTAIN MANUFACTURER OR PREFERENCE.
Panel Name: EH1A Bussing Amps: 225 Panel Location: ROOM 104 Surface or Flush: SURFACE
Voltage: 277/480V Sections: ONE SECTION - 42X Phase/Wire: 3PH/3W AIC Rating: 18
New/Existing: Existing
Load VA Branch Load Data
Breaker Breaker Branch Load Data
Load VA Ph A Ph B Ph C Trip Pole No. Ph. No. Trip Pole Ph A Ph B Ph C 2188 LTG. - EAST WING FIRST FLOOR 20 1 1 a 2 20 1 LTG. - WEST WING FIRST FLOOR 1168
1314 LTG. - EAST WING SECOND FLOOR 20 1 3 b 4 20 1 LTG. - WEST WING SECOND FLOOR 834 SPACE -- 1 5 c 6 -- SPACE SPACE -- 1 7 a 8 -- SPACE SPACE -- 1 9 b 10 -- SPACE SPACE -- 1 11 c 12 -- SPACE SPACE -- 1 13 a 14 -- SPACE SPACE -- 1 15 b 16 -- SPACE SPACE -- 1 17 c 18 -- SPACE SPACE -- 1 19 a 20 -- SPACE SPACE -- 1 21 b 22 -- SPACE SPACE -- 1 23 c 24 -- SPACE SPACE -- 1 25 a 26 -- SPACE SPACE -- 1 27 b 28 -- SPACE SPACE -- 1 29 c 30 -- SPACE SPARE 20 1 31 a 32 -- SPACE
6 ASTRONOMICAL TIME CLOCK 20 1 33 b 34 -- SPACE 214 LIGHT POLES 20 1 35 c 36 -- SPACE
64 WALL PACKS 20 1 37 a 38
125 3 75 KVA TRANSFORMER
1000 COLONADES LIGHTING SOUTH 20 1 39 b 40 2500
600 COLONADES LIGHTING WEST 20 1 41 c 42 2500 2252 2320 814 Sum per phase (VA) right side 3668 3334 2500 3668 3334 2500 5920 5654 3314
53% 21 amps Total Connected (VA): 14888 30 amps Total Connected Amps: 21
Calculated Load (Amps) @ ## 21
LUMINAIRE SCHEDULE
TYPE DESCRIPTION SOURCE VOLTAGE TOTAL VA
MANUFACTURER
MOUNTINGBASIS OF DESIGN
TYPE CCT(K) LUMENS NAME CATALOG SERIES
A ARCH LIGHT LED 4000 2300 120-277 50 VISA OW1721_L40K_H WALL MOUNTED
B LIGHT POLE LED 5000 3500 120-277 26 LITHONIA RADPT_LED_P1_50K_SYM POLE MOUNTED
C LIGHT POLE WITH ARMS LED 5000 6350 120-277 54 LITHONIA RAD1_LED_P3_50K_PATH POLE MOUNTED
D DOOR WALLPACK LED 5000 1500 120-277 16 LITHONIA ARC2_LED_P1_50K_MVOLT_4W4H_
PE WALL MOUNTED
E1 6'' CAN LED 5000 1500 120-277 18 LITHONIA LDN6_50/_15_L06_WR_LD_TRW RECESSED
E2 6'' CAN LED 5000 500 120-277 6 LITHONIA LDN6_50/_05_L06_WR_LD_TRW RECESSED
GENERAL NOTES:
A PRIOR TO SUBMITTAL VERIFY TRIM COMPATIBILITY WITH CEILING TYPE TO AVOID CONFLICTS.
B SHOULD ALTERNATE FIXTURES BE PROPOSED, EC SHALL PROVIDE PHOTOMETRICS FOR EACH SPACE CONTAINING PROPOSED ALTERNATES.
C FINAL FINISHES SHALL BE APPLIED AFTER FABRICATION.
D COORDINATE MOUNTING OF EXIT SIGNS WITH ARCHITECTURAL FEATURES.
SPECIFIC NOTES:
2 DOES UPDATE WORK?
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
LAS CRUCES WOOTON HALL EXTERIOR REPAIR DESIGN
USDA-ARS NEW MEXICO STATE UNIVERSITY
LAS CRUCES, NEW MEXICO
SCHEDULES AND DETAILS
E500 13 1303/19/2025
REH
DRL
JGM 2150 CENTRE AVENUE
BLDG D, SUITE 300
FORT COLLINS, CO 80526
XXX
2524-A
BD
XXX
EW
WR
#4 HOOP (TYP.)
EIGHT - #7 (TYP.)
1' - 6" MIN. BELOW GROUND
2' - 0" MIN. UNDER PAVEMENT
4" M
IN
3/4" CHAMFER (TYP.)
1/
2" C
LR
3"
5'
0"
#4 H
O O
PS
" S
PA
C
IN
G
2 1/2" CLR.
CONCRETE
EXTEND THE CONDUIT 6" MIN. BEYOND
THE FOUNDATION OR THE CONTROLLED
DENSITY BACKFILL
CLAMP CONDUCTOR TO STEEL
REINFORCING BAR WITH LISTED
CONNECTOR SUITABLE FOR
USE EMBEDDED IN CONCRETE
2'Ø MINIMUM **
** - DENOTES THAT THE DIMENSION
SHALL BE VERIFIED AND ADJUSTED TO
ACCOMMODATE THE LIGHT STANDARD.
THE STANDARD SHALL NOT OVERHANG
THE FOUNDATION
UNDISTURBED EARTH
1"Ø BOLT WITH 18"
MINIMUM EMBED
NEW LIGHT STANDARD
1/4" STEEL BAR STRAPS
BETWEEN ANCHORS
LEVEL WITH NON-SHRINK
GROUT, AS REQUIRED (1"
MAX)
SCALE:
LIGHT POLE STANDARD FOUNDATION
NONE
E500
| Arch |
| A100 |
| A100 |
| A101 |
| A101 |
| A200 |
| A200 |
| A201 |
| A201 |
| A300 |
| A300 |
| A301 |
| A301 |
| A302 |
| A302 |
| A303 |
| A303 |
| T100 |
| T100 |
| T101 |
| T101 |
| Elect |
| E001 |
| Sheets and Views |
| E001 |
| E100 |
| Sheets and Views |
| E100 |
| E500 |
| Sheets and Views |
| E500 |
Blank Page
File details come from the government source that posted it. Updated .