Text version

TR

C1514A

TR

C1671A

TR

C1772A

TR

C1864A TR

C1999D

TR

ECM07

AREA WELL

SA102k

ELECTRICAL

A1115

ELECTRICAL

A1114

ELECTRICAL

A1113

CORRIDOR

CA135

MECHANICAL

A1116

VAULT

A1112A

OFFICE

A1111

CONTROLED DRUGS

A1112

COMPRESSOR ROOM

A1106

OFFICE

A1066

OFFICE

A1067

OFFICE

A1068

OFFICE

A1072

MENS LOCKERS

A1060

MENS TOILET

A1059

WOMENS TOILET

A1057

WOMENS LOCKERS

A1058

OFFICE

A1065

OFFICE

A1062

OFFICE

A1101

WOMENS TOILET

A1040

MENS TOILET

A1041 H.A.C.

A1042

CART LIFT #03

SA102l

CANTEEN STORAGE

A1048

CANTEEN STORAGE

A1054

OFFICE

A1046

OFFICE

A1045

TOILET

A1047

STORAGE

A1033

CANTEEN STORAGE

A1039

CONSULATION ROOM

A1102

CANTEEN KITCHEN

A1052

CORRIDOR

A1053

WALK IN REFRIGERATOR

A1052A

WALK IN REFRIGERATOR

A1052B PREP

A1036

H.A.C.

A1037

CANTEEN

A1032

CORRIDOR

CA116STORAGE

A1014

OFFICE

A1013

OFFICE

A1012

OFFICE

A1011

OFFICE

A1010

ELECTRICAL

A1028

ELECTRICAL

A1029

OFFICE

A1023

OFFICE

A1022

H.A.C.

A1021

STORAGE

A1019

TOILET

A1020

CORRIDOR

CA115

OFFICE

A1015

OFFICE

A1017

OFFICE

A1016

LOUNGE

A1018

KITCHEN

A1018A

CORRIDOR

CA112

CORRIDOR

CA113

CORRIDOR

CA114

ELECTRICAL

A1026

STAIR #02

SA102

MECHANICAL

A1024

DINING

A1038

RECEPTION

A1103

WAITING

A1100

PHARMACY

A1104

PHARMACY

A1105

PHARMACY

A1110

PHARMACY

A1109

WAITING

A1088

CORRIDOR

CA126

LOUNGE

A1056

CORRIDOR

CA127

STORAGE

A1061

CORRIDOR

CA128

OFFICE

A1063

H.A.C.

A1055

SOILED UTILITY

A1051

CORRIDOR

CA122

CHAPLAIN OFFICE

A1069

CORRIDOR

CA129

OFFICE

A1070

OFFICE

A1071

CART LIFT #01

SA102pCART LIFT #02

SA102q

SUBSTATION

SA102s

SUBSTATION

SA102t

TR

A1026A

ELEVATOR #07

SA102u

PUMP ROOM

A1042A

CORRIDOR

SA102jj

CORRIDOR

SA102kk

CORRIDOR

SA102llTR

A1115A

WOMES TOILET

B1296A

WOMENS SHOWER

B1296B

TOILET

B1220

OFFICE

B1221

STORAGE

B1222

GROUP ACTIVITIES

B1223

ART SINK

B1224

VENDING

B1227

SUBSTATION

B1228

ELECTRICAL

B1229

ELECTRICAL

B1230

VESTIBULE

B1232

TOILET

B1232AWAITING

B1233 H.A.C.

B1234

NURSE

B1235

CONFERENCE

B1236

OFFICE

B1237

OFFICE

B1238

OFFICE

B1239

OFFICE

B1240

OFFICE

B1241

WAITING

B1242

OFFICE

B1243

RECEPTION

B1244

OFFICE

B1245

OFFICE

B1246

OFFICE

B1247

OFFICE

B1248

STORAGE

B1249

OFFICE

B1250

EXAM

B1251

TOILET

B1253

CLEAN SUPPLY

B1254

CORRIDOR

CB129

CORRIDOR

CB135OFFICE

B1271

EXAM

B1272

FILE ROOM

B1273

CORRIDOR

B1274

TRIAGE

B1276

RECEPTION

B1278

LIFE MACHINE ALCOVE

B1279

MECHANICAL

B1231

CORRIDOR

B1215

CORRIDOR

CB126STORAGE

B1290A

CORRIDOR

CB134

MULTI-PURPOSE ROOM

B1290

STORAGE

B1291

KITCHEN

B1292

STORAGE

B1289

CORRIDOR

B1293C

WOMENS LOCKER

B1296

MENS LOCKER

B1293

CORRIDOR

B1297

LOBBY/RECEPTION

B1303

MENS SHOWER

B1293B

CORRIDOR

CB116

CORRIDOR

CB115

CORRIDOR

CB113

CORRIDOR

CB119

CORRIDOR

CB109

CORRIDOR

CB112 CORRIDOR

B1311

FILE ROOM

B1312

WAITING

B1313

RECEPTION

B1315

TOILET

B1317

SOILED UTILITY

B1319

EXAM

B1321

STAFF TOILET

B1323

EXAM

B1324D

EXAM

B1324

WORK ROOM

B1320

SCHEDULERS

B1322

OFFICE

B1327

EXAM

B1326

EXAM

B1328

CORRIDOR

B1329

EXAM

B1330

OFFICE

B1331EXAM

B1332

EXAM

B1334

EXAM

B1336

MECHANICAL

B1338

ELECTRICAL

B1340ELECTRICAL

B1340A

STAIR #06

SB106

SUBSTATION

B1343

ELEC

B1343A

OFFICE

B1344

OFFICE

B1345

OFFICE

B1346

H.A.C.

B1347

OFFICE

B1348

OFFICE

B1350

OFFICE

B1352

WAITING

B1353

CONFERENCE

B1354

OFFICE

B1355

TOILET

B1356

OFFICE

B1357

EXAM

B1358

OFFICE

B1359

CORRIDOR

CB107

OFFICE

B1362

PHARMACY

B1363

OFFICE

B1364

OFFICE

B1366

OFFICE

B1368

OFFICE

B1369

WAITING

B1370

OFFICE

B1371

OFFICE

B1372

OFFICE

B1373

EXAM

B1374

CORRIDOR

CB114

CONFERENCE

B1375

CORRIDOR

CB130

AUDIO BOOTH

B1341

CLEAN SUPPLY

B1339

TOILET

B1337

EXAM

B1335

EXAM

B1324A

EXAM

B1324B

EXAM

B1324C

EXAM

B1324E

STORAGE

B1329A

STORAGE

CB112A

TOILET

B1360

STORAGE

B1299

OFFICE

B1304

OFFICE

B1305

JUICE BAR

B1210

CORRIDOR

B1296C

H.A.C.

B1294

FITNESS CENTER

B1214

BREAK ROOM/ CONFERENCE

B1325

OFFICE

B1333

STORAGE

B1329B

TR

B1340B

TR

B1230A

100-MD301A

1100-MD301A

100-MD301A

100-MD301A

100-MD301A

100-MD301A

100-MD301A

100-MD301A

100-MD300B

100-MD301B

100-MD301B

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:3 :3

P

M

100-MD101

MECHANICAL DEMOLITION PLAN -

FIRST FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - FIRST FLOOR

No. Revisions: Date:

BID DOCUMENTS 01/09/2023

01/09/2023

UPUP

C2465A

TR

C2571A

TR

C2741A

TR

C2981AELECTRICAL

C2465

ELECTRICAL

C2571

ELECTRICAL

C2741

ELECTRICAL

C2981

AREA WELL

SA102k

CLEAN UTILITY

A2026

OFFICE

A2028

CAST ROOM

A2033

H.A.C.

A2036

STORAGE

A2035

OFFICE

A2038

SOILED UTILITY

A2040 MECHANICAL

A2032

ELECTRICAL

A2031

BEDROOM 2 BED

A2029

BEDROOM 2 BED

A2027

BEDROOM 2 BED

A2025

BEDROOM 2 BED

A2023

BEDROOM 2 BED

A2021

BEDROOM 2 BED

A2019

BEDROOM 2 BED

A2017

BEDROOM 2 BED

A2015

BEDROOM 2 BED

A2013

CLASS ROOM

A2011

BATH

A2013ACLOSET

A2011B

CLOSET

A2011A

BATH

A2015A

BATH

A2019A

BATH

A2023A

BATH

A2027A

ANTE

A2037B

BEDROOM ISOLATION

A2037

BEDROOM ISOLATION

A2039

BATH

A2039A

BATH

A2037A

ANTE

A2039B

BEDROOM 1 BED

A2041

BEDROOM 1 BED

A2043

BATH

A2041A

BEDROOM 1 BED

A2045

BEDROOM 1 BED

A2047

BATH

A2045A

BATH

A2049A

BEDROOM 1 BED

A2049

BEDROOM 1 BED

A2051

BEDROOM 2 BED

A2053

BEDROOM 2 BED

A2055

BATH

A2053A

LINEN ROOM

A2024

STAFF TOILET

A2042

OFFICE

A2046

OFFICE

A2022

OFFICE

A2020

EXAM / TREATMENT ROOM

A2048

MEDICATION PREP

A2016

OFFICE

A2018

KITCHEN

A2050

NURSES STATION

A2044CORRIDOR

CA210

CORRIDOR

CA208

NURSES STATION

A2014

OFFICE

A2109

OFFICE

A2111

MENS LOCKERS

A2113

MENS TOILET

A2113A

WOMENS TOILET

A2058A

WOMENS LOCKERS

A2058

OFFICE

A2057

OFFICE

A2061OFFICE

A2063

CORRIDOR

CA218

CONSULATION ROOM

A2101

OFFICE

A2007

OFFICE

A2005

OFFICE

A2010

OFFICE

A2012

BREAK ROOM

A2103

CORRIDOR

CA216

STORAGE PHARMACEUTI

A2107 OFFICE

A2062

ELECTRICAL

A2067

DAY ROOM

A2059

BEDROOM 2 BED

A2117

ICU PHYSICIAN CALL ROOM

A2115

BATH

A2115A

ICU BEDROOM

A2133

ICU BEDROOM

A2131

ICU BEDROOM

A2129

ICU BEDROOM

A2127

ICU BEDROOM

A2125

ICU BEDROOM

A2123

ICU BEDROOM

A2121

ICU BEDROOM

A2119

BEDROOM 2 BED

A2164

BEDROOM 2 BED

A2162

BEDROOM 2 BED

A2160

ICU BEDROOM ISOLATION

A2158

BATH

A2160A

ANTE

A2158A

BATH

A2162A

ICU BEDROOM

A2156

ICU BEDROOM

A2154

ICU BEDROOM

A2152

ICU BEDROOM

A2150

ICU BEDROOM

A2148

ICU BEDROOM

A2146

SIMULATION ROOM

A2163

CONSULATION ROOM

A2116

STORAGE / EQUIPMENT

A2118

OFFICE

A2161

OFFICE

A2120 CORRIDOR

CA217

ICU BEDROOM ISOLATION

A2144

ANTE

A2144A

ELECTRICAL

A2140

KITCHEN

A2147

LINEN ROOM

A2138H.A.C.

A2136

KITCHEN

A2130

NURSES STATION

A2151

NURSES STATION

A2151A

MEDICATION PREP

A2155

MEDICATION PREP

A2128

LOUNGE

A2153 CLEAN UTILITY

A2159STAFF TOILET

A2126

SOILED UTILITY

A2134

OFFICE

A2132

BIOMED

A2149

CORRIDOR

CA221

CORRIDOR

CA222

CORRIDOR

CA223

CORRIDOR

CA220

CORRIDOR

CA224

CORRIDOR

CA215

MECHANICAL

A2141

CORRIDOR

CA211

CORRIDOR

CA207

STAIR #02

SA202

TR

A2140A CART LIFT #01

SA102wCART LIFT #02

SA102x

CART LIFT #03

SA102y

TR

A2031A

UTILITY ROOM

B2210

UTILITY ROOM

B2212

OCCUPANCY THERAPY

B2216

GROUP ROOM

B2294

NURSE STATION

B2218

CORRIDOR

CB216

DAY ROOM

B2293

BEDROOM 2 BED

B2217

BATH

B2217A

BEDROOM 2 BED

B2219

BEDROOM 2 BED

B2221

BATH

B222A

BEDROOM 2 BED

B2223

GROUP ROOM

B2224

BEDROOM 2 BED

B2225

BATH

B2225A

EXAM

B2226

BEDROOM 2 BED

B2227

OFFICE

B2228

BEDROOM 2 BED

B2229

BATH

B2229A

OFFICE

B2230

BEDROOM 2 BED

B2231

TOILET

B2232

BEDROOM 2 BED

B2233

BATH

B2233A

STORAGE

B2234

BEDROOM 2 BED

B2235

MECHANICAL

B2236

SECLUSION

B2237

SECLUSION BATH

B2237A

SECLUSION ANTE

B2237B

TR

B2239A

LINEN ROOM

B2251

CORRIDOR

CB214

CORRIDOR

CB207

OFFICE

B2252

OFFICE

B2253

VESTIBULE

B2254

UTILITY ROOM

B2255

LOCKER

B2254A

LOCKER

B2254B

TOILET

B2254C

TOILET

B2254D

OFFICE

B2257

HYDROTHERAPY STORAGE

B2259

STORAGE

B2259A

CORRIDOR

CB210

CORRIDOR

CB211

OFFICE

B2261

BATH

B2261A

ANTE

B2261B

OFFICE

B2263

BATH

B2263A

ANTE

B2263B

OFFICE

B2265

STORAGE

B2267

OFFICE

B2264

OFFICE

B2266

OFFICE

B2268

OFFICE

B2269

BATH

B2269A

ANTE

B2269B

CONFERENCE ROOM

B2270

OFFICE

B2271

OFFICE

B2272

STORAGE

B2273

OFFICE

B2275

BATH

B2275A

ANTE

B2275B

OFFICE

B2277

STORAGE

B2279

OFFICE

B2281

BATH

B2281A

ANTE

B2281B

OFFICE

B2283

KITCHEN

B2285

OFFICE

B2286

OFFICE

B2287

OFFICE

B2288

EXAM

B2289

OFFICE

B2290

EXAM

B2291

OFFICE

B2292

COPY ROOM

B2220

OFFICE

B2306OFFICE

B2310

COPY ROOM

B2312

BREAK ROOM

B2314

CORRIDOR

CB218

GROUP ROOM

B2324

KITCHEN

B2325

DAY ROOM

B2326

CONFERENCE ROOM

B2327

NURSE STATION

B2318

CHARTING

B2322

CORRIDOR

CB220

CORRIDOR

CB221

CORRIDOR

CB222

CORRIDOR

CB223

CORRIDOR

CB224

BEDROOM 1 BED

B2329

BATH

B2329A

SECLUSION BEDROOM

B2330

TOILET

B2330A

SECLUSION ANTE

B2330B

BEDROOM 1 BED

B2331

BATH

B2331ABEDROOM 1 BED

B2333

BATH

B2333A

BEDROOM 1 BED

B2335

H.A.C.

B2336

BEDROOM 1 BED

B2337

OFFICE

B2338

BEDROOM 1 BED

B2339

OFFICE

B2340

BEDROOM 1 BED

B2341

BATH

B2337A

BATH

B2341A

BEDROOM 1 BED

B2343

STORAGE

B2345

VESTIBULE

B2346

CLEAN UTILITY

B2347

OFFICE

B2348

UTILITY ROOM

B2349

STORAGE

B2345A

LOCKER

B2346ALOCKER

B2346B

TOILET

B2346C

TOILET

B2346D

STORAGE

B2351

CLEAN LINEN

B2353

OTHER SPACE

B2355

MECHANICAL

B2357

ELECTRICAL

B2359

STAIR #06

SB206

BEDROOM 2 BED

B2363

BATH

B2363A

BEDROOM 2 BED

B2365

OFFICE

B2366

BEDROOM 2 BED

B2367

OFFICE

B2368

BEDROOM 2 BED

B2369

BATH

B2367A

BEDROOM 2 BED

B2371

BATH

B2371A

BEDROOM 2 BED

B2373

BEDROOM 2 BED

B2375

BATH

B2375A

BEDROOM 2 BED

B2377

SECLUSION BEDROOM

B2378

BEDROOM 2 BED

B2379

SECLUSION BATH

B2378A

SECLUSION ANTE

B2378B

BATH

B2379A

BEDROOM 2 BED

B2381

OFFICE

B2382

SECLUSION BEDROOM

B2383BOFFICE

B2384

SECLUSION BEDROOM

B2385

OFFICE

B2386

SECLUSION BATH

B2383A

SECLUSION ANTE

B2383

TOILET

B2385A

SECLUSION ANTE

B2385BTOILET

B2388

MED ROOM

B2390

STORAGE

B2392

EXAM

B2394

CART LIFT #05

CART LIFT #06

TR

B2359A

ELECTRICAL

B2239

100-MD302

1100-MD302

100-MD302

100-MD302

100-MD302

100-MD302

100-MD302

100-MD302

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:3 :3

P

M

100-MD102

MECHANICAL DEMOLITION PLAN -

SECOND FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - SECOND FLOOR

No. Revisions: Date:

C3841A

TR

C3747A

TR

C3676A

TR

C3554AELECTRICAL

C3554

ELECTRICAL

C3676

ELECTRICAL

C3747

ELECTRICAL

C3841

AREA WELL

SA102k

RECEPTION

A3019

RECEPTION

A3020

LOUNGE

A3012

OFFICE

A3013

OFFICE

A3014

OFFICE

A3015

OFFICE

A3016

OFFICE

A3017

TOILET

A3018

ELECTRICAL

A3031

MECHANICAL

A3032

EXAM

A3065

EXAM

A3063

LARGE EXAM ROOM

A3061

EXAM

A3059

TOILET

A3057

STORAGE

A3055

NURSE EXAM

A3054

EXAM

A3053

CLEAN UTILITY

A3051

SOILED UTILITY

A3049

EXAM

A3047

EXAM

A3045

EXAM

A3043

EXAM

A3066

EXAM

A3062

EXAM

A3060

STORAGE

A3058

NURSE EXAM

A3056

EXAM

A3052

EXAM

SA102m

EXAM

A3033

EXAM

A3035

EXAM

A3037

EXAM

A3039

EXAM

A3041

EXAM

A3042

EXAM

A3044

EXAM

A3046

EXAM

A3048

EXAM

SA102n

CPAP EXAM

A3030

CLOSET

A3030A

OFFICE

A3022

MEDICATION PREP

A3023

EXAM

A3034

EXAM

A3036

EXAM

A3038

EXAM

A3040

OFFICE

A3021

WAITING C

A3027

WAITING B

A3026

WAITING A

A3025

CORRIDOR

CA309

CORRIDOR

CA310

CORRIDOR

CA311

CORRIDOR

CA312

WAITING

SA102o

OFFICE

A3113

OFFICE

A3111

OFFICE

A3109

STORAGE PHARMACEUTI

A3107

ELECTRICAL

A3067

H.A.C.

A3068TOILET

A3069

OFFICE

A3103

MENS LOCKERS

A3101

WOMENS TOILET

A3010A

MENS TOILET

A3101A

WOMENS LOCKERS

A3010

CORRIDOR

CA307

CORRIDOR

CA308

CORRIDOR

CA318

WAITING

A3064

CORRIDOR

CA306

WAITING

A3070

BEDROOM 2 BED

A3115

BEDROOM 2 BED

A3117

BEDROOM 1 BED

A3119

BEDROOM 1 BED

A3121

BEDROOM 1 BED

A3123

BEDROOM 1 BED

A3125

BEDROOM 1 BED

A3127

BEDROOM 1 BED

A3129

BEDROOM ISOLATION

A3131

BEDROOM ISOLATION

A3133

ANTE

A3133B

BATH

A3133A

BATH

A3131A

ANTE

A3131B

BATH

A3127A

BATH

A3123A

BATH

A3119A

BATH

A3115A

NURSES STATION

A3104

MEDICATION PREP

A3106

KITCHEN

A3116

EXAM

A3118

LOUNGE

A3159

OFFICE

A3157

OFFICE

A3120STAFF TOILET

A3122

LINEN ROOM

A3155

SOILED UTILITY

A3126

CLEAN UTILITY

A3153

OFFICE

A3151

STORAGE / EQUIPMENT

A3128

STORAGE

A3136

H.A.C.

A3130

STORAGE

A3134

NURSES STATION

A3124

CORRIDOR

CA322

CORRIDOR

CA324

BEDROOM 2 BED

A3146

BEDROOM 2 BED

A3148

BEDROOM 2 BED

A3150

BEDROOM 2 BED

A3152

BEDROOM 2 BED

A3154

BEDROOM 2 BED

A3156

BEDROOM 2 BED

A3158

BEDROOM 2 BED

A3160

BEDROOM 2 BED

A3162

CLASS ROOM

A3102

BATH

A3162A

BATH

A3139

BATH

A3154A

BATH

A3150A

BATH

A3146A CLOSET

A3102A

CLOSET

A3102BCORRIDOR

CA323

CORRIDOR

CA321

MECHANICAL

CA325

ELECTRICAL

A3142

STAIR #02

SA302

TR

A3142A

CONFERENCE ROOM

A3024

TR

A3031A

CART LIFT #01

SA102zCART LIFT #02

SA102aa

CART LIFT #03

SA102bb

OFFICE

B3310

OFFICE

B3312

OFFICE

B3314

TOILET

B3212T

CONFERENCE

B3324

CORRIDOR

CB318

CORRIDOR

CB323

CORRIDOR

CB324 CORRIDOR

CB320

CORRIDOR

CB321

CORRIDOR

CB322

RECEPTION

B3318

CLASSROOM

B3325

WAITING

B3326

LACTATION ROOM

B3327

EXAM

B3329

BATH

B3329A

EXAM

B3331

BATH

B3331AEXAM

B3333

BATH

B3333A

EXAM

B3335

EXAM

B3337

BATH

B3337A

EXAM

B3339

EXAM

B3341

BATH

B3341A

EXAM

B3343

TOILET

B3336

STORAGE

B3338

STORAGE

B3340

H.A.C.

B3345

HYDROTHERAPY STORAGE

B3346

CLEAN UTILITY

B3347

OFFICE

B3344

SOILED UTILITY

B3349

WOMENS LOCKER

B3350

OFFICE

B3351

STAFF LOUNGE

B3352

CLEAN LINEN

B3353

OFFICE

B3355

TOILET

B3350A

MENS LOCKER

B3348

TOILET

B3348A

MECHANICAL

B3357

ELECTRICAL

B3361

EXAM

B3363

BATH

B3363A

EXAM

B3365

EXAM

B3367

BATH

B3367A

EXAM

B3369

EXAM

B3371

BATH

B3371A

EXAM

B3373

EXAM

B3375

BATH

B3375A

EXAM

B3377

EXAM

B3379

EXAM

B3381

BATH

B3379A

EXAM

B3382

OFFICE

B3383

TELEHEALTH COORDINATORS

B3384

OFFICE

B3385

OFFICE

B3387

OFFICE

B3389

OFFICE

B3390

OFFICE

B3392

OFFICE

B3393

OFFICE

B3394

WORK ROOM

B3395

OFFICE

B3396

WORK ROOM

B3322CRASH CART

B3388

STORAGE

B3346A

EXAM

B3221

EXAM

B3220

EXAM

B3222

EXAM

B3223

EXAM

B3224

EXAM

B3225

EXAM

B3226

EXAM

B3227

EXAM

B3228

EXAM

B3229

EXAM

B3230

EXAM

B3231

EXAM

B3232

EXAM

B3233

EXAM

B3234

EXAM

B3235

MECHANICAL

B3236

EXAM

B3237

LOW VISION STORAGE

B3238

ELECTRICAL

B3239

H.A.C.

B3240

EXAM

B3250

EXAM

B3251

EXAM

B3252

EXAM

B3253

EXAM

B3254

EXAM

B3255

EXAM

B3256

EXAM

B3257

EXAM

B3258

EXAM

B3259

EXAM

B3260

EXAM

B3261

EXAM

B3262

EXAM

B3263

EXAM

B3264

EXAM

B3265

OFFICE

B3266TELE RETINAL READING

B3267

OCT/ ULTRASOUND

B3268

OCT/ ULTRASOUND

B3269

TOILET

B3270

OFFICE

B3271

CONFERENCE ROOM

B3272

OFFICE

B3273

STUDENT/ RESIDENT OFFICE

B3274

OFFICE

B3275

OFFICE

B3276

OFFICE

B3277

OFFICE

B3278

OFFICE

B3279

OFFICE

B3280

OFFICE

B3281

TELE RETINAL READING

B3282

OFFICE

B3283

OFFICE

B3284

BREAK ROOM

B3286

STAFF LOCKER

B3287

TOILET

B3288

TOILET

B3289

SOILED UTILITY

B3290

LASER ROOM

B3291

TONOMETER PROCESSING

B3292

LASER ROOM

B3293

CLEAN SUPPLY

B3294

MINOR PROCEDURE ROOM

B3295

MED ROOM

B3296

PHOTOGRAPHY

B3297

VISUAL FIELD

B3298

VISUAL FIELD

B3299

CLINIC COORDINATOR

B3216

OFFICES

CB313

CORRIDOR

CB314

CORRIDOR

CB307B

CORRIDOR

CB311

CORRIDOR

CB310

STORAGE

B3242

CORRIDOR

CB309

CORRIDOR

CB308

CORRIDOR

CB307A

CRASH CART

B3217

TOILET

B3211T

RECEPTION

B3210

WAITING

B3212

STAIR #06

SB306

TR

B3361A

CART LIFT #05

CART LIFT #06

TRASH CHUTE

B3243

OPTICAL

B3214

TR

B3239A

100-MD303

1100-MD303

100-MD303

100-MD303

100-MD303

100-MD303

100-MD303

100-MD303

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:3 :4

P

M

100-MD103

MECHANICAL DEMOLITION PLAN -

THIRD FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - THIRD FLOOR

No. Revisions: Date:

C4483A

TR

C4654A

TR

C4763A

TR

C4967A

ELECTRICAL

C4483

ELECTRICAL

C4654

ELECTRICAL

C4763

ELECTRICAL

C4967

AREA WELL

SA102k

BEDROOM ISOLATION

A4133

BEDROOM ISOLATION

A4131

BEDROOM 1 BED

A4129

BEDROOM 1 BED

A4127

BEDROOM 1 BED

A4125

BEDROOM 1 BED

A4123

BEDROOM 1 BED

A4121

BEDROOM 1 BED

A4119BEDROOM 2 BED

A4117

BEDROOM 2 BED

A4115

BATH

A4115A

BATH

A4119A

BATH

A4123A

BATH

A4127A

ANTE

A4131B

ANTE

A4133B

BATH

A4133A

BATH

A4131A

H.A.C.

A4130

STORAGE

A4136

STORAGE

A4134

OFFICE STAFF

A4151

STORAGE / EQUIPMENT

A4128 SOILED UTILITY

A4126

CLEAN UTILITY

A4153

LINEN ROOM

A4155

STAFF TOILET

A4122

OFFICE

A4120

OFFICE

A4157

OFFICE

A4159

LOUNGE

A4118

MEDICATION PREP

A4106

OFFICE

A4113

EXAM

A4059

EXAM

A4061

INTAKE

A4063

OFFICE

A4109

OFFICE

A4111

TOILET

A4070

STORAGE

A4072

STORAGE PHARMACEUTI

A4107

CORRIDOR

CA421

CORRIDOR

CA422

NURSES STATION

A4124

CORRIDOR

CA424

KITCHEN

A4116

NURSES STATION

A4104

CORRIDOR

CA418

PHYSICAL THERAPY CLINIC

A4057

CLASS ROOM

A4102

CLOSET

A4102B

CLOSET

A4102A

BATH

A4162A

BEDROOM 2 BED

A4162

BEDROOM 2 BED

A4160

BEDROOM 2 BED

A4158

BEDROOM 2 BED

A4156

BEDROOM 2 BED

A4154

BEDROOM 2 BED

A4152

BEDROOM 2 BED

A4148

BEDROOM 2 BED

A4150

BEDROOM 2 BED

A4146ELECTRICAL

A4144

CORRIDOR

A4083

BATH

A4146A

BATH

A4150A

BATH

A4154A

BATH

A4158A

MENS LOCKERS

A4101

MENS TOILET

A4101A

WOMENS TOILET

A4010A

UTILITY

A4103

SELF CHECK-IN

A4011

WOMENS LOCKERS

A4010

CORRIDOR

CA407

ELECTRICAL

A4075

MECHANICAL

A4074

EXAM

A4045RECEPTION

A4067

CORRIDOR

CA411

MAIN WAITING

A4064

MECHANICAL

A4141

STORAGE

A4071

OFFICE

A4020 N.C.

A4021 N.C.

A4022

CLEAN LINEN

A4023

H.A.C.

A4073

CORRIDOR

CA410

EXAM

A4024

CLEAN UTILITY

A4025

EXAM

A4026

EXAM

A4027

EXAM

A4028

EXAM

A4029

VAS LAB

A4030

WAITING C

A4033

WAITING B

A4034

WAITING A

A4035

EXAM

A4036

EXAM

A4037

EXAM

A4038

EXAM

A4039

SOILED UTILITY

A4040

EXAM

A4041

EXAM

A4042

EXAM

A4043

CAST ROOM

A4044

TOILET

A4046

STAFF TOILET

A4047

N.C.

A4048

MEDS

A4049

N.C.

A4050

N.C.

A4051

STORAGE

A4052

EXAM

A4053

EXAM

A4054

EXAM

A4055

EXAM

A4058

EXAM

SA102r

EXAM

A4060

EXAM

A4056

INTAKE

A4065

WORK ROOM

A4066

OFFICE

A4068

CHECK-OUT

A4069

EXAM

A4031

VAS LAB

A4032

CORRIDOR

CA413

CORRIDOR

CA412

MURSE MANAGER

A4012

ORTHO NURSE PRACTITIONERS

A4013

ORTHO PROVIDERS

A4014

ORTHO PROVIDERS

A4015

PODIATRY PROVIDERS

A4016

PODIATRY

A4017

NURSING STAFF WORKSTATIONS

A4018

STAFF BREAKROOM

A4019

STAIR #02

SA402

TR

A4144A

INTAKE

A4062

CART LIFT #01

SA102ccCART LIFT #02

SA102dd

CART LIFT #03

A4078

TR

A4075A

EQUIPMENT

B4305

OFFICE

B4306

DARK ROOM

B4307

OFFICE

B4308

OFFICE

B4481

STORAGE

B4280

OFFICE

B4250OFFICE

B4252

MENS TOILET

B4311

WOMENS TOILET

B4313

LAB

B4321

LUNCH ROOM

B4322

WALK-IN FRIDGE

B4322ALAB

B4324

LAB

B4323

LAB

B4325

LAB

B4326

LAB

B4327

LAB

B4328WALK-IN FRIDGE

B4330

COMPRESSOR ROOM

B4329

OFFICE

B4331

OFFICE

B4332

OFFICE

B4333

OFFICE

B4334

STORAGE

B4335

H.A.C.

B4336

CORRIDOR

CB422

CORRIDOR

CB421

CORRIDOR

CB424

SOILED LINEN

B4341

STORAGE

B4342

MECHANICAL ROOM

B4351

ELECTRICAL

B4355

STAIR #06

SB406

WALK-IN FRIDGE

B4360

LAB

B4361

LAB

B4362

LAB

B4363

LAB

B4364

LAB

B4365

LAB

B4366

LAB

B4367

LAB

B4368

LAB

B4369

CORRIDOR

CB415

CORRIDOR

CB416

CORRIDOR

CB417

CORRIDOR

CB418

CORRIDOR

CB423

CONFERENCE

B4260

OFFICE

B4262OFFICE

B4263

OFFICE

B4264

OFFICE

B4265

OFFICE

B4266

OTHER SPACE

B4267

OFFICE

B4268

OFFICE

B4269

OFFICE

B4270

CLEAN UTILITY ROOM

B4282

LAB

B4210

OFFICE

B4211

LAB

B4212

OFFICE

B4213

LAB

B4214

OFFICE

B4215

LAB

B4216

OFFICE

B4217

WALK-IN FRIDGE

B4218

MECHANICAL

B4222

ELECTRICAL

B4223

RESEARCH STORAGE

B4230

SOILED UTILITY

B4231H.A.C.

B4232

STORAGE

B4233

STORAGE

B4234

OFFICE

B4235

OFFICE

B4236

OFFICE

B4237

OFFICE

B4238

WALK-IN FRIDGE

B4240

LAB

B4241

LAB

B4242

LAB

B4243

LAB

B4244

LAB

B4245

LAB

B4246

LAB

B4247

LAB

B4248

CORRIDOR

CB407

CORRIDOR

CB408

CORRIDOR

CB410

CORRIDOR

CB411

CORRIDOR

CB419

TR

B4355A

CART LIFT #05

CART LIFT #06

TR

B4223A

100-MD304

1100-MD304

100-MD304

100-MD304

100-MD304

100-MD304

100-MD304

100-MD304

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:3 :5

P

M

100-MD104

MECHANICAL DEMOLITION PLAN -

FOURTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - FOURTH FLOOR

No. Revisions: Date:

ELECTRICAL

B5239

TR

A4144A

ELECTRICAL

A4075

ELECTRICAL

A4144

TR

B5239AELECTRICAL

B5378 100-MD305

1100-MD305

100-MD305

100-MD305

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:3 :5

P

M

100-MD105

MECHANICAL DEMOLITION PLAN -

FIFTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - FIFTH FLOOR

No. Revisions: Date:

A5144A

TR

A5031A

ELECTRICAL

A5031

ELECTRICAL

A5144

AREA WELL

SA102k

100-MD306

1100-MD306

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :0

P

M

100-MD106

MECHANICAL DEMOLITION PLAN -

SIXTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - SIXTH FLOOR

No. Revisions: Date:

A6031A

ELECTRICAL

A6031

ELECTRICAL

A6142

TR

A6142A

AREA WELL

SA102k

100-MD307

100-MD307

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :0

P

M

100-MD107

MECHANICAL DEMOLITION PLAN -

SEVENTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/32" = 1'-0"

MECHANICAL DEMOLITION PLAN - SEVENTH FLOOR

No. Revisions: Date:

T

T

T

T T

T

T

STAIR #06

SLL06

ELECTRICAL

LL411

TR

LL411A

SF-E EF-E

ELECTRICAL

LL050

CORRIDOR

CLL12

STAIR #02

SLL02

TR

LL050A

SF-E EF-E

TR

LL530A

TR

LL554A

TR

LL659A

TR

LL775A

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :0

P

M

100-MD300A

ENLARGED MECHANICAL DEMO

PLANS - LOWER LEVEL

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO LOWER LEVEL LL411A - ZONE 4

5 1/4" = 1'-0"

DEMO LOWER LEVEL LL212 - ZONE 6

6 1/4" = 1'-0"

DEMO LOWER LEVEL LL210A - ZONE 6

7 1/4" = 1'-0"

DEMO LOWER LEVEL LL050A - ZONE 1

1/4" = 1'-0"

DEMO LOWER LEVEL LL530A - ZONE 10

1 1/4" = 1'-0"

DEMO LOWER LEVEL LL554A - ZONE 10

2 1/4" = 1'-0"

DEMO LOWER LEVEL LL659A - ZONE 9

3 1/4" = 1'-0"

DEMO LOWER LEVEL LL775A - ZONE 9

No. Revisions: Date:

OFFICE

LL242

OFFICE

LL236

OFFICE

LL238

SERVER ROOM

LL246

ELECTRICAL

LL247

A C

-0

A C

-0

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :1

P

M

100-MD300B

ENLARGED MECHANICAL DEMO

PLANS - LOWER LEVEL

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

1/4" = 1'-0"

SERVER ROOM LL246 - ZONE 3 DEMOLITION

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

SHEET KEYNOTES:

1. CONTRACTOR TO RELOCATED EXISTING

PERFORATED FLOOR TILES WITHIN ROOM TO

IMPROVE AIR FLOW TO INLETS OF EXISTING

AND NEW IT RACKS. COORDINATE WITH

OWNER PRIOR TO MOVING FLOOR TILES.

# GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

No. Revisions: Date:

T T

T

T

T

CORRIDOR

CA114

ELECTRICAL

A1026

STAIR #02

SA102

TR

A1026A

SF-22 EF-288

ELECTRICAL

A1115

ELECTRICAL

A1114

CORRIDOR

CA135

TR

A1115A

ELECTRICAL

B1230

CORRIDOR

CB135

TR

B1230A

ELECTRICAL

B1340

ELECTRICAL

B1340A

STAIR #06

SB106

TR

B1340B

TR

C1772A

TR

C1864A

TR

C1514A

TR

C1671A

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :2

P

M

100-MD301A

ENLARGED MECHANICAL DEMO

PLANS - FIRST FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO FIRST FLOOR A1026A - ZONE 1

1 1/4" = 1'-0"

DEMO FIRST FLOOR A1115A - ZONE 2

2 1/4" = 1'-0"

DEMO FIRST FLOOR B1230A - ZONE 3

3 1/4" = 1'-0"

DEMO FIRST FLOOR B1340B - ZONE 4

1/4" = 1'-0"

DEMO FIRST FLOOR C1772A - ZONE 10

5 1/4" = 1'-0"

DEMO FIRST FLOOR C1864A - ZONE 9

6 1/4" = 1'-0"

DEMO FIRST FLOOR C1514A - ZONE 10

7 1/4" = 1'-0"

DEMO FIRST FLOOR C1617A - ZONE 10

No. Revisions: Date:

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

TR

C1999D

TR

ECM07

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :2

P

M

100-MD301B

ENLARGED MECHANICAL DEMO

PLANS - FIRST FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

NO SCALE

DEMO FIRST FLOOR C1999D - ZONE 11

NO SCALE

DEMO ECM07 - ENERGY CENTER - BLDG 103

No. Revisions: Date:

T

TT

T

T

T

ELECTRICAL

A2031

TR

A2031A

EF-290 SF-23

ANTE

A2144A

ELECTRICAL

A2140

TR

A2140A

EF-273 SF-18

SECLUSION BATH

B2237A

TR

B2239A

ELECTRICAL

B2239

ELECTRICAL

B2359

STAIR #06

SB206

TR

B2359A

TR

C2981A

ELECTRICAL

C2981

TR

C2741A

ELECTRICAL

C2741

TR

C2571A

ELECTRICAL

C2571

TR

C2465A

ELECTRICAL

C2465

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :3

P

M

100-MD302

ENLARGED MECHANICAL DEMO

PLANS - SECOND FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO SECOND FLOOR A2031A - ZONE 1

1 1/4" = 1'-0"

DEMO SECOND FLOOR A2140A - ZONE 2

2 1/4" = 1'-0"

DEMO SECOND FLOOR B2239A - ZONE 3

3 1/4" = 1'-0"

DEMO SECOND FLOOR B2359A - ZONE 4

1/4" = 1'-0"

DEMO SECOND FLOOR C2981A - ZONE 9

5 1/4" = 1'-0"

DEMO SECOND FLOOR C2741A - ZONE 9

6 1/4" = 1'-0"

DEMO SECOND FLOOR C2571A - ZONE 10

7 1/4" = 1'-0"

DEMO SECOND FLOOR C2465A - ZONE 10

No. Revisions: Date:

T

T T T T

ELECTRICAL

A3031

STAIR #02

SA302

TR

A3031A

ELECTRICAL

A3142

TR

A3142A

EF-275 SF-19

ELECTRICAL

B3239

TR

B3239A

ELECTRICAL

B3361

STAIR #06

SB306

TR

B3361A

TR

C3747A

ELECTRICAL

C3747

TR

C3841AELECTRICAL

C3841

TR

C3554A

ELECTRICAL

C3554

TR

C3676A

ELECTRICAL

C3676

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :4

P

M

100-MD303

ENLARGED MECHANICAL DEMO

PLANS - THIRD FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO THIRD FLOOR A3031A - ZONE 1

1 1/4" = 1'-0"

DEMO THIRD FLOOR A3142A - ZONE 2

2 1/4" = 1'-0"

DEMO THIRD FLOOR B3239A - ZONE 3

3 1/4" = 1'-0"

DEMO THIRD FLOOR B3361A - ZONE 4

1/4" = 1'-0"

DEMO THIRD FLOOR C3747A - ZONE 9

5 1/4" = 1'-0"

DEMO THIRD FLOOR C3841A - ZONE 9

6 1/4" = 1'-0"

DEMO THIRD FLOOR C3554A - ZONE 10

7 1/4" = 1'-0"

DEMO THIRD FLOOR C3676A - ZONE 10

No. Revisions: Date:

T

T

T T

T

ELECTRICAL

A4075

TR

A4075A

SF-25 EF-294

ELECTRICAL

A4144

TR

A4144A

EF-275 SF-19

ELECTRICAL

B4223

TR

B4223A

SF-30 EF-266

ELECTRICAL

B4355

STAIR #06

SB406

TR

B4355A

TR

C4967A

ELECTRICAL

C4967

TR

C4763A

ELECTRICAL

C4763

TR

C4654A

ELECTRICAL

C4654 TR

C4483A

ELECTRICAL

C4483

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :5

P

M

100-MD304

ENLARGED MECHANICAL DEMO

PLANS - FOURTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO FOURTH FLOOR A4075A - ZONE 1

1 1/4" = 1'-0"

DEMO FOURTH FLOOR A4144A - ZONE 2

2 1/4" = 1'-0"

DEMO FOURTH FLOOR B4223A - ZONE 3

3 1/4" = 1'-0"

DEMO FOURTH FLOOR B4355A - ZONE 4

1/4" = 1'-0"

DEMO FOURTH FLOOR C4967A - ZONE 9

5 1/4" = 1'-0"

DEMO FOURTH FLOOR C4763A - ZONE 9

1/4" = 1'-0"

DEMO FOURTH FLOOR C4654A - ZONE 10

7 1/4" = 1'-0"

DEMO FOURTH FLOOR C4483A - ZONE 10

No. Revisions: Date:

T

T

ELECTRICAL

A4075

SF-26 EF-296

TR

A4144A

ELECTRICAL

A4144

EF-279 AF-174

ELECTRICAL

B5239

TR

B5239A

AF-162

ELECTRICAL

B5378

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :5

P

M

100-MD305

ENLARGED MECHANICAL DEMO

PLANS - FIFTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO FIFTH FLOOR A5031A - ZONE 1

1 1/4" = 1'-0"

DEMO FIFTH FLOOR A5144A - ZONE 2

2 1/4" = 1'-0"

DEMO FIFTH FLOOR B5239A - ZONE 3

3 1/4" = 1'-0"

DEMO FIFTH FLOOR B5378A - ZONE 4

No. Revisions: Date:

TR

A5031A

ELECTRICAL

A5031

SF-27 EF-298

TR

A5144A

ELECTRICAL

A5144

EF-281 AF-176

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :0

P

M

100-MD306

ENLARGED MECHANICAL DEMO

PLANS - SIXTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO SIXTH FLOOR A6031A - ZONE 1

1 1/4" = 1'-0"

DEMO SIXTH FLOOR A6142A - ZONE 2

No. Revisions: Date:

ELECTRICAL

A6142TR

A6142A

EF-(E) AF-(E)

TR

A6031A

ELECTRICAL

A6031

GENERAL SHEET NOTES:

1. COORDINATE ALL DEMOLITION WORK WITH ALL

OTHER TRADES AND OWNER'S PROJECT

REPRESENTATIVE.

2. COORDINATE ANY SHUTDOWNS OF EXISTING

SERVICES OR EQUIPMENT WITH OWNER.

3. REFERENCE 100-MH001 FOR ADDITIONAL

DEMOLITION NOTES.

DEMOLITION KEYNOTES:

1. RELOCATE EXISTING THERMOSTAT FOR

EXISTING MECHANICAL SYSTEM. REFER TO

NEW WORK PLANS FOR LOCATION.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :0

P

M

100-MD307

ENLARGED MECHANICAL DEMO

PLANS - SEVENTH FLOOR

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

1/4" = 1'-0"

DEMO SEVENTH FLOOR A7142A - ZONE 2

1 1/4" = 1'-0"

DEMO SEVENTH FLOOR A7031A - ZONE 1

No. Revisions: Date:

DN

DN

OFFICE

LL191

OFFICE

LL193

CONFERENCE ROOM

LL171

BREAK ROOM

LL172

OFFICE

LL174

OFFICE

LL176

OFFICE

LL180

OFFICE

LL182

OFFICE

LL181

OFFICE

LL179

OFFICE

LL177

OFFICE

LL196

OFFICE

LL194

OFFICE

LL192

OFFICE

LL186CORRIDOR

CLL27CORRIDOR

CLL26

CORRIDOR

CLL28 OFFICE

LL183

OFFICE

LL184

STORAGE

LL187

TOILET

LL185

CLOSET

LL184ACONTROLED DRUGS

LL104

PHARMACY VAULT

LL105

STORAGE

LL107

H.A.C.

LL103

NON-HAZARDOUS BUFFER AREA

LL101A

HAZARDOUS BUFFER AREA

LL102A

ANTE

LL102

CLEAN ROOM

LL101

STORAGE

LL106 PHARMACY

LL109

CORRIDOR

CLL24

PHARMACY

LL100

PHARMACY

LL100A

OFFICE

LL115

OFFICE

A7116

OFFICE

A7118

OFFICE

LL117

RESEARCH LAB

LL119

OFFICE

LL127

WOMENS TOILET

LL129A

WOMENS LOCKERS

LL129

MENS LOCKERS

LL128

MENS TOILET

LL128A

LOUNGE

LL126

OFFICE

LL124

PHARMACY

LL111

ELECTRICAL

LL108

EXAM

LL020

CONSULATION ROOM

LL058

MRI ROOM

LL059

SIMULATION ROOM

LL061

TOILET

LL062

TREATMENT CONTROL ROOM

LL066

TREATMENT ROOM

LL067

CAST BLOCK ROOM

LL054

COMPUTER ROOM

LL056

ELECTRICAL

LL050

CORRIDOR

CLL12

WOMENS TOILET

LL028

MENS TOILET

LL030

LAB

LL053

SEALED SOURCE ROOM

LL055

RADIATION THERAPY

LL026

SOILED UTILITY

LL027

CLEAN UTILITY

LL025

H.A.C.

LL023

OFFICE

LL021

OFFICE

LL039

OFFICE

LL037

OFFICE

LL035

OFFICE

LL033

STORAGE

LL032

LOUNGE

LL034

OFFICE

LL036

OFFICE

LL038

OFFICE

LL040

CORRIDOR

CLL08

STORAGE

LL013

TOILET

LL015

EXAM

LL017

EXAM

LL019

CORRIDOR

CLL19

CORRIDOR

CLL17

CHANGING ROOM

LL063

LOCKERS

LL064

CHANGING ROOM

LL065

CORRIDOR

CLL05

STORAGE

LL012

CLERK

LL011

WAITING

LL010

CORRIDOR

CLL09

CORRIDOR

CLL10

STORAGE

XXX

ELEVATOR #07

TREATMENT ROOM

LL068

STAIR #02

SLL02

CORRIDOR

LL123

CORRIDOR

CLL15

CORRIDOR

CLL16

CORRIDOR

CLL13

CORRIDOR

CLL11

CORRIDOR

CLL14

CORRIDOR

CLL29

CORRIDOR

CLL07

TR

LL050A

CART LIFT #03

SA102j

MECHANICAL

LL052

PHARMACY CAGE

LL109A

AREA WELL

SA102k

CONFERENCE

LL219

SOILED UTILITY

LL340

OFFICE

LL242

OFFICE

LL235

OFFICE

LL236

OFFICE

LL237

OFFICE

LL238

STORAGE

LL239

OFFICE

LL220

CORRIDOR

CLL48

STORAGE

LL225

COMPUTER ROOM

LL228

SERVER ROOM

LL246 ELECTRICAL

LL247

STORAGE

LL300

OFFICE

LL302

OFFICE

LL303

STORAGE

LL301

LAB

LL308

COMPRESSOR ROOM

LL309

WALK-IN FRIDGE

LL310

OFFICE

LL311

OFFICE

LL312

OFFICE

LL313

OFFICE

LL314

OFFICE

LL315

OFFICE

LL316

STORAGE

LL317

STORAGE

LL318

UTILITY ROOM

LL319

LAB

LL320

LAB

LL321

LAB

LL322

LAB

LL323

LAB

LL324

LAB

LL325

LAB

LL326

LAB

LL327

LAB

LL328

CORRIDOR

CLL58

CORRIDOR

CLL59

CORRIDOR

CLL67

CORRIDOR

CLL68

LAB

LL330

LAB

LL333

H.A.C.

LL334

ANIMAL HOUSING

LL342

ANIMAL HOUSING

LL343

ANIMAL HOUSING

LL344

CAGE STORAGE

LL345

ANIMAL HOUSING

LL346

ANIMAL HOUSING

LL347

ANIMAL HOUSING

LL348

ANIMAL HOUSING

LL349

ANIMAL HOUSING

LL350

ANIMAL HOUSING

LL351

ANIMAL HOUSING

LL352

ANIMAL HOUSING

LL353

LOUNGE

LL355

CORRIDOR

CLL65

CORRIDOR

CLL64

CORRIDOR

CLL62

ANIMAL HOUSING

LL370

CORRIDOR

CLL71

OFFICE

LL357

OFFICE

LL358

LAB

LL359

LAB

LL360

LAB

LL361

LAB

LL362

LAB

LL363

FOOD/BEDDING

LL364

LOCKER

LL365

STORAGE

LL366

LOCKER

LL367

KITCHEN

LL364A

WALK-IN FRIDGE

LL364B TOILET

LL365A

TOILET

LL367A

ANIMAL HOUSING

LL372

LOCKER

LL374

TOILET

LL374A

CORRIDOR

CLL77

LAB

LL376

LAB

LL378

LAB

LL380

LAB

LL379

CART LIFT

LL381

WOMENS LOCKER

LL382

TOILET

LL382A

CORRIDOR

CLL74

CORRIDOR

CLL75

CORRIDOR

CLL73

MENS LOCKER

LL384

STORAGE

LL385

UTILITY ROOM

LL388

OPERATING ROOM

LL389

UTILITY ROOM

LL390

OPERATING ROOM

LL391

H.A.C.

LL392

LAB

LL394

LAB

LL396

OFFICE

LL398

KITCHEN

LL398A

STAIR #06

SLL06

LAB

LL402

REFRIGERATOR

LL402A

LAB

LL404

CLEAN UTILITY ROOM

LL399

ANIMAL CAGE WASHER

LL400

STORAGE

LL340A

CORRIDOR

CLL70

CORRIDOR

CLL72

LAB

LL406

STORAGE

LL407

H.A.C.

LL408

COMPRESSOR ROOM

LL409

LAB

LL410

ELECTRICAL

LL411

MECHANICAL

LL412

CART LIFT #06

AREA WELL

TOILET

LL384A

TR

LL411A

GROUND MAINTENANCE GARAGE

ECL01

OFFICE

ECL01A

H.A.C.

ECL02

TOILET

ECL03

TOILET

ECL04

UTILITY ROOM

ECL05

PUMP ROOM

ECL06

SOIL CART STAGING

ECL07

MECHANICAL ROOM

ECL08TRASH RECEIVING

ECL09

PUMP ROOM

ECL06A

STORAGE

ECL11

WASH

ECL07A

CORRIDOR

ECCL1

CORRIDOR

CECL2

STAIRS

EC103-1

STAIRS

EC103-2

STORAGE

ECL10

STAIR

EC103-3

100-MH300A

100-MH300B

100-MH300A

100-MH300A

100-MH300A

100-MH300A

100-MH300A

100-MH300A

100-MH300A

STORAGE

LL500 HAZARDOUS WASTE

LL501

EMS RECEIVING

LL504 OXYGEN STORAGE

LL502

EMS STORAGE

LL505 EMS STORAGE

LL503ELECTRICAL

LL511

STORAGE

LL509

STORAGE

LL507

STORAGE

LL508

STORAGE

LL510COMPRESSOR ROOM

LL506

CORRIDOR

CLL83

CORRIDOR

CLL82

MECHANICAL

LL528

STAIR #08

SLL08 CORRIDOR

CLL99

ELECTRICAL

LL530

TOILET

LL520

OFFICE

LL521

OFFICE

LL523

VAULT

LL524

CLOSET

LL525

COMPRESSOR ROOM

LL527

STAIR #12

SLL12WALK-IN REFRIGERATOR

LL526

LOADING DOCK

LL518

CORRIDOR

CLL84SOILED LINEN

LL514

STORAGE

LL512

CLEAN LINEN

LL515

STORAGE

LL513

MECHANICAL

LL556

ELECTRICAL

LL554

CORRIDOR

CLL98

STAIR #09

SLL09

TOILET

LL553A

TOILET

LL551A

LOCKERS

LL551

LOCKERS

LL553

CLEAN RECEIVING

LL549

OFFICE

LL545

ELEVATOR ROOM

LL547

CART LIFT #07

WAREHOUSE STORAGE

LL517

WAREHOUSE STORAGE

LL516

OFFICE

LL637

OFFICE

LL635

OFFICE

LL634

OFFICE

LL636

CONFERENCE ROOM

LL638

STORAGE

LL621

H.A.C.

LL620

STORAGE FLAMMABLE

LL656

PAINT SHOP

LL653

OFFICE

LL654

STAIR #10

SLL10

SPRAY BOOTH

LL652

MECHANICAL

LL670

CORRIDOR

CLL97

MECHANICAL

LL658

ELECTRICAL

LL659

OFFICE

LL671

OFFICE

LL651

ELECTRIC SHOP

LL650

OFFICE

LL648 OFFICE

LL647

OFFICE

LL646 OFFICE

LL645

OFFICE

LL644

OFFICE

LL640

OFFICE

LL643

TOILET

LL641

TOILET

LL675

PLOTER ROOM

LL639

CORRIDOR

CLL89

OFFICE

LL633

CONFERENCE

LL623

MECHANICAL

LL776

STAIR #11

SLL11

ELECTRICAL

LL775

CORRIDOR

CLL96

STAIR #13

SLL13

FILE ROOM

LL772

OFFICE

LL770

OFFICE

LL769

H.A.C.

LL812

SHOWER

LL813

TOILET

LL814

OFFICE

LL815

CORRIDOR

CLL109

OFFICE

LL820

OFFICE

LL821

OFFICE

LL822

OFFICE

LL823

OFFICE

LL831

CONFERENCE ROOM

LL836

KITCHEN

LL807

STORAGE

LL806STORAGE EQUIPMENT

LL805

ARMORY

LL804EVIDENCE

LL803

CORRIDOR

CLL107

CORRIDOR

CLL108

OFFICE

LL824

OFFICE

LL825

WAITING

LL827

CORRIDOR

CLL106

COMPUTER ROOM

LL830

HOLDING

LL802

OFFICE

LL801

DISPATCH

LL800

CARPENTER SHOP

LL672

MECHANICAL / PIPE SHOP

LL673

FLIGHT OPS

LL676

OFFICE

LL674

STORAGE EQUIPMENT

LL682

BIOMEDICAL ENGINEERING SHOP

LL678

OFFICE

LL679

H.A.C.

LL680

OFFICE

LL681

CART LIFT #08

CORRIDOR

CLL87

LOCKERS

LL607

TOILET

LL607A

LOUNGE

LL540

CHANGING ROOM

LL606

LOCKERS

LL608

TOILET

LL608A

H.A.C.

LL610

STORAGE

LL604

MSD STORAGE

LL548

SPS

LL546SPS RECEPTION

LL544

CORRIDOR

CLL88

CORRIDOR

CLL86

PREP ROOM

LL558

GAS ROOM

LL559

OFFICE

LL600

WASH BAY

LL601 H.A.C.

LL603

DECONTAMINATION ROOM

LL605

WASHING MECHANICAL

LL602

MAIL ROOM

LL686

REPRODUCTION ROOM

LL692

OFFICE

LL695

OFFICE

LL693

OFFICE

LL691

OFFICE

LL689

OFFICE

LL687

CORRIDOR

CLL93

CORRIDOR

CLL91

CORRIDOR

CLL105

OFFICE

LL712

OFFICE

LL700

STORAGE

LL771

ELEVATOR MACHINE ROOM

LL768

H.A.C.

LL767

TOILET

LL766

OFFICE

LL765

WAITING

LL763

CORRIDOR

CLL94

OFFICE

LL764

OFFICE

LL761

OFFICE

LL760

LOUNGE

LL762

OFFICE

LL750

CORRIDOR

CLL92

OFFICE

LL740

OFFICE

LL738

LOCKERS

LL811

ELECTRIC SHOP

LL682A

LOUNGE

LL678A

LOCKSMITH

LL805A

MEDICAL SUPPLY

LL550

TR

LL775A

TR

LL659A

TR

LL554A

TR

LL530A

IT STORAGE

LL519

CORRIDOR

CLL676

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

C R e v it L o c a l F ile s \M

V

A D e tr o it E

H R

M C

J a s o n .C

.C o o p e r.

rv t

/6

/2

:4 :2

P

M

100-MH100

MECHANICAL PLAN - LOWER

LEVEL

01/09/2023 PP JC

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

33533 W 12 MILE, SUITE 200

FARMINGTON HILLS, MI 48331

248.344.2800 FAX: 248.344.1650

www.imegcorp.com

©2023 IMEG CORP. PROJECT #

REF. SCALE IN INCHES0 1 2

IMEG CORP. RESERVES PROPRIETARY RIGHTS,

INCLUDING COPYRIGHTS, TO THIS DRAWING AND THE

DATA SHOWN THEREON. SAID DRAWING AND/OR

DATA ARE THE EXCLUSIVE PROPERTY OF IMEG CORP.

AND SHALL NOT BE USED OR REPRODUCED FOR ANY

OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP.

21006564.00

1/32" = 1'-0"

MECHANICAL PLAN - LOWER LEVEL

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

No. Revisions: Date:

LL183

OFFICE

LL184

STORAGE

LL187

TOILET

LL185

CLOSET

LL184A

CONTROLED DRUGS

LL104

PHARMACY VAULT

LL105

STORAGE

LL107

H.A.C.

LL103

NON-HAZARDOUS BUFFER AREA

LL101A

HAZARDOUS BUFFER AREA

LL102A

ANTE

LL102

CLEAN ROOM

LL101

STORAGE

LL106

PHARMACY

LL109

CORRIDOR

CLL24

PHARMACY

LL100

PHARMACY

LL100A

OFFICE

LL115

OFFICE

A7116 OFFICE

A7118

OFFICE

LL117

RESEARCH LAB

LL119

OFFICE

LL127WOMENS TOILET

LL129A

WOMENS LOCKERS

LL129

MENS LOCKERS

LL128

MENS TOILET

LL128A

LOUNGE

LL126

OFFICE

LL124

PHARMACY

LL111

ELECTRICAL

LL108

EXAM

LL020

CONSULATION ROOM

LL058

MRI ROOM

LL059

SIMULATION ROOM

LL061

TOILET

LL062

TREATMENT CONTROL ROOM

LL066

TREATMENT ROOM

LL067

CAST BLOCK ROOM

LL054

COMPUTER ROOM

LL056

ELECTRICAL

LL050

CORRIDOR

CLL12

WOMENS TOILET

LL028

MENS TOILET

LL030

LAB

LL053

SEALED SOURCE ROOM

LL055RADIATION THERAPY

LL026

SOILED UTILITY

LL027CLEAN UTILITY

LL025

H.A.C.

LL023

OFFICE

LL021

OFFICE

LL039

OFFICE

LL037…