SITE LOCATION

JOHN D. DINGELL VA MEDICAL CENTER

#553-21-701

DEPARTMENT OF VETERANS AFFAIRS

4646 JOHN R. STREET DETROIT, MICHIGAN 48201

EHRM INFRASTRUCTURE UPGRADES

G E N E R A L N O T E S

1. SEE GENERAL PROJECT NOTES FOR NEW WORK FOR ADDITIONAL REQUIREMENTS FOR WORK WITHIN THE

EXISTING FACILITY.

2. THE CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS AND FIELD CONDITIONS PRIOR TO

DEMOLITION AND CONSTRUCTION. IF PROVIDED, THE GENERAL CONTRACTOR SHALL CAREFULLY

EXAMINE EXISTING BUILDING DOCUMENTS. THE CONTRACTOR SHALL BRING ANY DISCREPANCIES TO THE

IMMEDIATE ATTENTION OF THE ARCHITECT.

3. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF EXISTING ITEMS TO REMAIN DURING

DEMOLITION AND CONSTRUCTION.

4. MAINTAIN EXIT EGRESS PATHS TO EXISTING EXIT DOORS DURING CONSTRUCTION.

5. THE CONTRACTOR IS RESPONSIBLE FOR THE PROTECTION OF ALL CONSTRUCTION ROUTES BEYOND THE

AREAS OF WORK AND THE ROUTES MUST BE RETURNED TO THEIR ORIGINAL CONDITION AT THE END OF

THE PROJECT.

6. ALL DEMOLITION AND CONSTRUCTION ACTIVITIES SHALL BE COORDINATED WITH THE C.O.R. TO MINIMIZE

DISRUPTIONS OF NORMAL FUNCTIONS OF THE VA'S OCCUPIED AREAS.

7. IF CONSTRUCTION NOISE IS ANTICIPATED, SUBMIT A WRITTEN REQUEST TO THE C.O.R. FOR THE

SCHEDULED TIME OF THE CONSTRUCTION ACTIVITIES. NO WORK SHALL BE DONE WITHOUT THE WRITTEN

APPROVAL OF THE C.O.R. THE C.O.R. RESERVES THE RIGHT TO DISCONTINUE NOISY CONSTRUCTION AT

ANY TIME. NO RADIOS SHALL BE PERMITTED AT ANY TIME IN WORK AREAS ADJACENT TO OCCUPIED

SPACES.

8. ALL EXISTING SERVICES AND UTILITIES SHALL BE MAINTAINED TO AREAS THAT ARE IN OPERATION AND

SERVED BY THEM. COORDINATE ALL DISRUPTIONS OR DISCONTINUATIONS OF UTILITIES AND SERVICES

WITH C.O.R. NO SHUT DOWN OF EXISTING SERVICES IS ALLOWED TO OCCUR UNTIL RECEIVING THE

C.O.R.'S WRITTEN APPROVAL OF THE SHUT DOWN SCHEDULE. PROVIDE TEMPORARY SERVICES AND/OR

UTILITIES DURING INTERRUPTIONS AS REQUIRED AND APPROVED BY THE C.O.R.

9. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO PREVENT DAMAGE TO THE V.A.'S

AREAS ADJACENT TO NEW CONSTRUCTION OR AREAS WHERE VARIOUS SYSTEM CONNECTIONS OR

EXTENSIONS ARE REQUIRED. IN THESE AREAS, THE CONTRACTOR IS RESPONSIBLE FOR DAMAGE

CAUSED BY LACK OF SUFFICIENT PROTECTION FROM THE WEATHER AND FROM THE RESULTS OF ALL

CONSTRUCTION ACTIVITY INCLUDING BUT NOT LIMITED TO DUST AND WATER.

10. THE CONTRACTOR SHALL RECEIVE WRITTEN APPROVAL FROM THE C.O.R. BEFORE USING OPEN FLAMES, WELDING RODS AND TORCHES. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS AND METHODS TO

PROHIBIT THE MIGRATION OF SMOKE AND OTHER PRODUCTS OF COMBUSTION INTO OCCUPIED AREAS OF

THE EXISTING BUILDING AND FOR OBTAINING ALL REQUIRED PERMITS RELATED TO HOT WORK.

11. DO NOT OVERLOAD THE EXISTING BUILDING STRUCTURE. MAINTAIN THE STRUCTURAL INTEGRITY OF ALL

STRUCTURAL FRAMING MEMBERS AND SYSTEMS AT ALL TIMES.

12. ALL DEMOLISHED MATERIAL, EXCEPT MATERIAL THAT IS LISTED OR MARKED FOR RETENTION, SHALL

BECOME THE PROPERTY OF THE CONTRACTOR AND IT SHALL BE DISPOSED OF. NO DEBRIS RESULTING

FROM WORK SHALL BE LEFT IN THE CONSTRUCTION ROUTES BEYOND THE AREAS OF WORK.

13. REMOVAL OF A PARTICULAR ITEM IS TO INCLUDE ALL RELATED ITEMS, SUCH AS REMOVAL OF WALLS

WOULD INCLUDE ASSOCIATED DOORS, HARDWARE, ELECTRICAL, PLUMBING, MECHANICAL, ETC. REFER

TO DEMOLITION DRAWINGS FOR MORE INFORMATION. FOR ALL REMOVALS, THE GENERAL CONTRACTOR

SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO MECHANICAL, ELECTRICAL AND PLUMBING.

14. THE CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ITEMS NOT DEMOLISHED OR REMOVED

AS REQUIRED UNTIL PERMANENT SUPPORT IS PROVIDED IN THE FINAL CONSTRUCTION.

15. ALL OPENINGS IN EXISTING WALLS, CEILINGS AND FLOORS, WHICH ARE THE RESULT OF REMOVALS AND

OTHER NEW CONSTRUCTION ACTIVITY, SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE

EXISTING MATERIALS OR AS NOTED ON DRAWINGS. IF THE PATCH IS TO BE MADE IN FIRE RATED

CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE PATCH SHALL BE FINISHED

TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.

16. ALL EXISTING OPENINGS IN CEILINGS, FLOORS AND WALLS DISCOVERED IN THE EXISTING STRUCTURE

SHALL BE PATCHED WITH NEW MATERIALS THAT MATCH THE EXISTING MATERIALS. IF THE PATCH IS TO

BE MADE IN FIRE RATED CONSTRUCTION, THE PATCH MUST ACHIEVE THE REQUIRED FIRE RATING. THE

PATCH SHALL BE FINISHED TO A LIKE NEW CONDITION TO MATCH THE EXISTING FINISH.

17. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS SUBSTRATE FOR THE

ATTACHMENT OR APPLICATION OF NEW MATERIALS OR CONSTRUCTION, PREPARE OR ALTER THE

EXISTING SURFACES AS NECESSARY TO PROPERLY ACCOMMODATE THE NEW MATERIALS.

18. FIELD VERIFY SIZES AND DIMENSIONS OF ALL EXISTING UTILITIES THAT IMPACT THE NEW WORK.

DETERMINE THE SIZE AND LOCATION THE PENETRATIONS FROM THE EXISTING UTILITIES WITHIN THE NEW

WORK. SEAL TIGHT TO ALL PENETRATIONS AND CAULK.

19. PENETRATIONS THROUGH EXISTING FIRE RATED CONSTRUCTION MUST BE PROPERLY CLOSED AND FIRE

SAFE'D TO ACHIEVE THE REQUIRED FIRE RATING BY THE END OF CONSTRUCTION OPERATIONS FOR EACH

DAY.

20. NEW HOLES IN EXISTING ROOF STRUCTURES FOR NEW WORK MUST BE COORDINATED WITH THE

EXISTING STRUCTURE SO THAT CRITICAL STRUCTURAL MEMBERS ARE NOT DAMAGED.

21. UNLESS OTHERWISE NOTED, THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL EXISTING

SALVAGED STOCK BEFORE ORDERING NEW MATERIAL.

E X I S T I N G F A C I L I T I E S:

1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE LOCAL, STATE AND FEDERAL AUTHORITIES, CODES, RULES AND REGULATIONS.

2. THESE DOCUMENTS SHOW THE MINIMUM CONSTRUCTION REQUIREMENTS AND THE MINIMUM QUALITY OF WORK EXPECTED. MORE STRINGENT REQUIREMENTS STIPULATED WITHIN RELEVANT MANUFACTURER’S

INSTALLATION INSTRUCTIONS WILL SUPERSEDE.

3. ANY UNFORESEEN OR UNCLEAR CONDITIONS SHALL BE REPORTED TO THE C.O.R. PRIOR TO PROCEEDING

WITH WORK.

4. ANY CONFLICTS WITHIN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, OR BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS AT THE SITE, ARE TO BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE C.O.R. THE CONTRACTOR SHALL NOT PROCEED WITH WORK UNTIL

WRITTEN CLARIFICATION FROM THE ARCHITECT IS RECEIVED.

5. UNLESS OTHERWISE NOTED, ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED PER THE APPLICABLE

PROVISIONS OF THESE DOCUMENTS AND THE MANUFACTURER’S INSTRUCTIONS.

6. ALL MATERIALS USED SHALL BE NEW UNLESS OTHERWISE NOTED AND/OR OF A QUALITY TO MEET OR EXCEED ALL APPLICABLE INDUSTRY STANDARDS. WHERE SPECIFIED PRODUCTS OR MANUFACTURERS ARE

NOT NOTED, THE CONTRACTOR IS REQUIRED TO NOTIFY THE ARCHITECT TO OBTAIN A MINIMUM

STANDARD OF QUALITY.

7. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL MEANS, METHODS AND TECHNIQUES FOR

CONSTRUCTION.

8. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR JOB-SITE SAFETY INCLUDING BUT NOT LIMITED TO THE

ADHERENCE TO OSHA REGULATIONS.

9. ALL ELECTRICAL AND MECHANICAL WORK SHALL BE PERFORMED BY PERSONNEL LICENSED IN THE STATE

WHERE THIS PROJECT IS LOCATED.

10. REMOVE ALL DEBRIS PROPERLY FROM THE SITE. LOAD DEBRIS DIRECTLY ONTO TRUCKS OR INTO VA PROVIDED DUMPSTERS FOR REMOVAL. DISPOSE OF DEBRIS LEGALLY. DO NOT BURN DEBRIS ON THE SITE.

DO NOT ALLOW DEBRIS TO ENTER SEWERS. DO NOT ALLOW PILED DEBRIS TO ENDANGER STRUCTURES, BLOCK EXISTS OR ROADWAYS. COMBUSTIBLE WASTE WHICH COULD CREATE A FIRE HAZARD SHALL NOT

BE PERMITTED TO ACCUMULATE IN OR AROUND THE CONSTRUCTION SITE.

11. COORDINATE ALL WORK WITH ALL OTHER DISCIPLINES, INCLUDING, BUT NOT LIMITED TO MECHANICAL, ELECTRICAL, PLUMBING & SITE DRAWINGS. EXACT SIZE AND LOCATION OF ALL ROOF AND FLOOR OPENINGS SHOWN ON ARCHITECTURAL DRAWINGS SHALL BE VERIFIED WITH THE ASSOCIATED SUB-

CONTRACTORS PRIOR TO CONSTRUCTION.

12. DO NOT SCALE DRAWINGS. DIMENSIONS SHALL GOVERN. ALL PLAN DIMENSIONS ARE TAKEN TO FINISH

FACE OF CONSTRUCTION.

13. ALL CONCEALED WOOD SHALL BE FIRE RETARDANT TREATED.

14. THE CONTRACTOR SHALL COORDINATE WITH ALL OTHER DISCIPLINES INCLUDING BUT NOT LIMITED TO MECHANICAL, ELECTRICAL, AND PLUMBING. SEAL CONSTRUCTION TIGHT TO ALL PENETRATIONS AND

CAULK.

15. ALL PENETRATIONS THROUGH FIRE RATED CONSTRUCTION MUST BE FIRE SAFE'D IN ACCORDANCE WITH THE SPECIFICATIONS. IF FLOOR OR RATED WALL PENETRATIONS CANNOT BE FIRESTOPPED AT THE END OF THE WORK SHIFT DUE TO THE NEED TO PULL ADDITIONAL CABLES, TEMPORARY FIRESTOPPING COMPOSED OF MINERAL WOOL SHOULD BE INSTALLED IN THE PENETRATION TO PROVIDE PROTECTION

AGAINST FIRE/SMOKE SPREAD THROUGH THE UNSEALED PENETRATION.

16. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING ALL EQUIPMENT INSTALLATION AND VERIFYING ALL REQUIRED ROUGH OPENINGS, AND ROUGH-IN DIMENSIONS WITH THE EQUIPMENT MANUFACTURER, C.O.R. PRIOR TO CONSTRUCTION.

17. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL FURNITURE AND EQUIPMENT MOVES

NECESSARY TO COMPLETE CONTRACT WORK.

N E W W O R K:

SHEET NAMING EXAMPLE:

100-AE101

100 = BUILDING NUMBER

AE = DISCIPLINE

101 = SHEET TYPE AND NUMBER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:5

:3

P

M

100-GI000

COVER SHEET VOLUME 1

01/09/2023 PH NM

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTS

JOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:5

:3

P

M

100-GI000

COVER SHEET VOLUME 1

01/09/2023 PH NM

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTS

JOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

N

12" = 1'-0"

VICINITY MAP

N

12" = 1'-0"

VA CAMPUS SITE MAP

DIRECTOR, MEDICAL CENTER

PAMELA REEVES

ASSOCIATE DIRECTOR, MEDICAL CENTER

MICHELLE WERNER

CHIEF, FACILITIES MANAGEMENT SERVICES

CASEY P. THAYER

ASSOCIATE CHIEF, FACILITY MANAGEMENT SERVICES

ROBERT PETERS

CHIEF, PASS

GEORGE CHESTER

CHIEF SAFETY

JEFF EDGE

CHIEF, VOLUNTEER SERVICES

BILL BROWNING

VOLUME (1/2)

S H E E T I N D E X

SHEET

NUMBER SHEET NAME

GENERAL

100-GI000 COVER SHEET VOLUME 1

100-GI001 SCHEDULES, PARTITION TYPES AND ABBREVIATIONS

100-GI002 EXISTING CONDITIONS

100-GI003 CODE ANALYSIS

ARCHITECTURE

100-AE100 OVERALL LOWER LEVEL FLOOR PLAN

100-AD400 LOWER LEVEL DEMOLITION PLANS

100-AD400A LOWER LEVEL DEMOLITION PLANS

100-AE400 ENLARGED LOWER LEVEL FLOOR PLANS

100-AE400A ENLARGED LOWER LEVEL FLOOR PLANS

100-AE101 OVERALL FIRST FLOOR PLAN

100-AD401 FIRST FLOOR DEMOLITION PLANS

100-AD401A FIRST FLOOR DEMOLITION PLANS

100-AE401 ENLARGED FIRST FLOOR PLANS

100-AE401A ENLARGED FIRST FLOOR PLANS

100-AE102 OVERALL SECOND FLOOR PLAN

100-AD402 SECOND FLOOR DEMOLITION PLANS

100-AE402 ENLARGED SECOND FLOOR PLANS

100-AE103 OVERALL THIRD FLOOR PLAN

100-AD403 THIRD FLOOR DEMOLITION PLANS

100-AE403 ENLARGED THIRD FLOOR PLANS

100-AE104 OVERALL FOURTH FLOOR PLAN

100-AD404 FOURTH FLOOR DEMOLTION PLANS

100-AE404 ENLARGED FOURTH FLOOR PLANS

100-AE105 OVERALL FIFTH FLOOR PLAN

100-AD405 FIFTH FLOOR DEMOLITION PLANS

100-AE405 ENLARGED FIFTH FLOOR PLANS

100-AE106 OVERALL SIXTH FLOOR PLAN

100-AD406 SIXTH FLOOR DEMOLATION PLANS

100-AE406 ENLARGED SIXTH FLOOR PLANS

100-AE107 OVERALL SEVENTH FLOOR PLAN

100-AD407 SEVENTH FLOOR DEMOLITION PLANS

100-AE407 ENLARGED SEVENTH FLOOR PLANS

AE500 ARCHITECTURAL DETAILS

FIRE PROTECTION

100-FX100 FIRE PROTECTION PLAN - LOWER LEVEL FLOOR NEW OVERALL

100-FX101 FIRE PROTECTION PLAN - FIRST FLOOR NEW OVERALL

100-FX102 FIRE PROTECTION PLAN - SECOND FLOOR NEW OVERALL

100-FX103 FIRE PROTECTION PLAN - THIRD FLOOR NEW OVERALL

100-FX104 FIRE PROTECTION PLAN - FOURTH FLOOR NEW OVERALL

100-FX105 FIRE PROTECTION PLAN - FIFTH FLOOR NEW OVERALL

100-FX106 FIRE PROTECTION PLAN - SIXTH FLOOR NEW OVERALL

100-FX107 FIRE PROTECTION PLAN - SEVENTH FLOOR NEW OVERALL

100-FX400 ENLARGED FIRE PROTECTION PLAN - LOWER LEVEL FLOOR

100-FX401 ENLARGED FIRE PROTECTION PLAN - FIRST FLOOR

100-FX402 ENLARGED FIRE PROTECTION PLAN - SECOND FLOOR

100-FX403 ENLARGED FIRE PROTECTION PLAN - THIRD FLOOR

100-FX404 ENLARGED FIRE PROTECTION PLAN - FOURTH FLOOR

100-FX405 ENLARGED FIRE PROTECTION PLAN - FIFTH FLOOR

100-FX406 ENLARGED FIRE PROTECTION PLAN - SIXTH FLOOR

100-FX407 ENLARGED FIRE PROTECTION PLAN - SEVENTH FLOOR

MECHANICAL

100-MH001 MECHANICAL COVERSHEET

100-MD100 MECHANICAL DEMOLITION PLAN - LOWER LEVEL

100-MD101 MECHANICAL DEMOLITION PLAN - FIRST FLOOR

100-MD102 MECHANICAL DEMOLITION PLAN - SECOND FLOOR

100-MD103 MECHANICAL DEMOLITION PLAN - THIRD FLOOR

100-MD104 MECHANICAL DEMOLITION PLAN - FOURTH FLOOR

100-MD105 MECHANICAL DEMOLITION PLAN - FIFTH FLOOR

100-MD106 MECHANICAL DEMOLITION PLAN - SIXTH FLOOR

100-MD107 MECHANICAL DEMOLITION PLAN - SEVENTH FLOOR

100-MD300A ENLARGED MECHANICAL DEMO PLANS - LOWER LEVEL

100-MD300B ENLARGED MECHANICAL DEMO PLANS - LOWER LEVEL

100-MD301A ENLARGED MECHANICAL DEMO PLANS - FIRST FLOOR

100-MD301B ENLARGED MECHANICAL DEMO PLANS - FIRST FLOOR

100-MD302 ENLARGED MECHANICAL DEMO PLANS - SECOND FLOOR

100-MD303 ENLARGED MECHANICAL DEMO PLANS - THIRD FLOOR

100-MD304 ENLARGED MECHANICAL DEMO PLANS - FOURTH FLOOR

100-MD305 ENLARGED MECHANICAL DEMO PLANS - FIFTH FLOOR

100-MD306 ENLARGED MECHANICAL DEMO PLANS - SIXTH FLOOR

100-MD307 ENLARGED MECHANICAL DEMO PLANS - SEVENTH FLOOR

100-MH100 MECHANICAL PLAN - LOWER LEVEL

100-MH100i.1 MECHANICAL PLAN - LOWER LEVEL INTERSTITIAL PLAN - ZONE 1

100-MH100i.2 MECHANICAL PLAN - LOWER LEVEL INTERSTITIAL PLAN - ZONE 2

100-MH100i.3 MECHANICAL PLAN - LOWER LEVEL INTERSTITIAL PLAN - ZONE 3

100-MH100i.4 MECHANICAL PLAN - LOWER LEVEL INTERSTITIAL PLAN - ZONE 4

100-MH100i.9 MECHANICAL PLAN - LOWER LEVEL INTERSTITIAL PLAN - ZONE 9

100-MH100i.10 MECHANICAL PLAN - LOWER LEVEL INTERSTITIAL PLAN - ZONE 10

100-MH101 MECHANICAL PLAN - FIRST FLOOR

100-MH101i.1 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL PLAN - ZONE 1

100-MH101i.2 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL PLAN - ZONE 2

100-MH101i.3 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL PLAN - ZONE 3

100-MH101i.4 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL PLAN - ZONE 4

100-MH101i.9 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL PLAN - ZONE 9

100-MH101i.10 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL PLAN - ZONE 10

100-MH101i.11 MECHANICAL PLAN - FIRST FLOOR INTERSTITIAL PLAN - ZONE 11

100-MH101i.99 MECHANICAL PLAN - MEZZANINE PLAN BLDG E

100-MH102 MECHANICAL PLAN - SECOND FLOOR

100-MH102i.1 MECHANICAL PLAN - SECOND FLOOR INTERSTITIAL PLAN - ZONE 1

100-MH102i.2 MECHANICAL PLAN - SECOND FLOOR INTERSTITIAL PLAN - ZONE 2

100-MH102i.3 MECHANICAL PLAN - SECOND FLOOR INTERSTITIAL PLAN - ZONE 3

100-MH102i.4 MECHANICAL PLAN - SECOND FLOOR INTERSTITIAL PLAN - ZONE 4

100-MH102i.9 MECHANICAL PLAN - SECOND FLOOR INTERSTITIAL PLAN - ZONE 9

100-MH102i.10 MECHANICAL PLAN - SECOND FLOOR INTERSTITIAL PLAN - ZONE 10

100-MH103 MECHANICAL PLAN - THIRD FLOOR

100-MH103i.1 MECHANICAL PLAN - THIRD FLOOR INTERSTITIAL PLAN - ZONE 1

100-MH103i.2 MECHANICAL PLAN - THIRD FLOOR INTERSTITIAL PLAN - ZONE 2

100-MH103i.3 MECHANICAL PLAN - THIRD FLOOR INTERSTITIAL PLAN - ZONE 3

100-MH103i.4 MECHANICAL PLAN - THIRD FLOOR INTERSTITIAL PLAN - ZONE 4

100-MH103i.9 MECHANICAL PLAN - THIRD FLOOR INTERSTITIAL PLAN - ZONE 9

100-MH103i.10 MECHANICAL PLAN - THIRD FLOOR INTERSTITIAL PLAN - ZONE 10

100-MH104 MECHANICAL PLAN - FOURTH FLOOR

100-MH104i.1 MECHANICAL PLAN - FOURTH FLOOR INTERSTITIAL PLAN - ZONE 1

100-MH104i.2 MECHANICAL PLAN - FOURTH FLOOR INTERSTITIAL PLAN - ZONE 2

100-MH104i.3 MECHANICAL PLAN - FOURTH FLOOR INTERSTITIAL PLAN - ZONE 3

100-MH104i.4 MECHANICAL PLAN - FOURTH FLOOR INTERSTITIAL PLAN - ZONE 4

100-MH104i.9 MECHANICAL PLAN - FOURTH FLOOR INTERSTITIAL PLAN - ZONE 9

100-MH104i.10 MECHANICAL PLAN - FOURTH FLOOR INTERSTITIAL PLAN - ZONE 10

100-MH105 MECHANICAL PLAN - FIFTH FLOOR

100-MH105i.1 MECHANICAL PLAN - FIFTH FLOOR INTERSTITIAL PLAN - ZONE 1

100-MH105i.2 MECHANICAL PLAN - FIFTH FLOOR INTERSTITIAL PLAN - ZONE 2

100-MH105i.3 MECHANICAL PLAN - FIFTH FLOOR INTERSTITIAL PLAN - ZONE 3

100-MH105i.4 MECHANICAL PLAN - FIFTH FLOOR INTERSTITIAL PLAN - ZONE 4

100-MH106 MECHANICAL PLAN - SIXTH FLOOR

100-MH106i.1 MECHANICAL PLAN -SIXTH FLOOR INTERSTITIAL PLAN - ZONE 1

100-MH106i.2 MECHANICAL PLAN -SIXTH FLOOR INTERSTITIAL PLAN - ZONE 2

100-MH107 MECHANICAL PLAN - SEVENTH FLOOR

100-MH107i.1 MECHANICAL PLAN -SEVENTH FLOOR INTERSTITIAL PLAN - ZONE 1

100-MH107i.2 MECHANICAL PLAN -SEVENTH FLOOR INTERSTITIAL PLAN - ZONE 2

100-MH300A ENLARGED MECHANICAL PLANS - LOWER LEVEL

100-MH300B ENLARGED MECHANICAL PLANS - LOWER LEVEL

100-MH301A ENLARGED MECHANICAL PLANS - FIRST FLOOR

100-MH301B ENLARGED MECHANICAL PLANS - FIRST FLOOR

100-MH302 ENLARGED MECHANICAL PLAN - SECOND FLOOR

S H E E T I N D E X

SHEET

NUMBER SHEET NAME

100-MH303 ENLARGED MECHANICAL PLAN - THIRD FLOOR

100-MH304 ENLARGED MECHANICAL PLAN - FOURTH FLOOR

100-MH305 ENLARGED MECHANICAL PLAN - FIFTH FLOOR

100-MH306 ENLARGED MECHANICAL PLAN - SIXTH FLOOR

100-MH307 ENLARGED MECHANICAL PLAN - SEVENTH FLOOR

100-MH400 MECHANICAL CONTROLS

100-MH500 MECHANICAL DETAILS

100-MH600 MECHANICAL SCHEDULES

ELECTRICAL

100-EE001 ELECTRICAL LEGEND

100-ED100 ELECTRICAL PLAN - LOWER LEVEL FLOOR OVERALL

100-ED400A ELECTRICAL DEMOLITION PLAN - LOWER LEVEL FLOOR

100-ED400B ELECTRICAL DEMOLITION PLAN - LOWER LEVEL FLOOR

100-ED101 ELECTRICAL PLAN - FIRST FLOOR OVERALL

100-ED401A ELECTRICAL DEMOLITION PLAN - FIRST FLOOR

100-ED401B ELECTRICAL DEMOLICTION PLAN - FIRST FLOOR

100-ED102 ELECTRICAL PLAN - SECOND FLOOR OVERALL

100-ED402 ELECTRICAL DEMOLITION PLAN - SECOND FLOOR

100-ED103 ELECTRICAL PLAN - THIRD FLOOR OVERALL

100-ED403 ELECTRICAL DEMOLITION PLAN - THIRD FLOOR

100-ED104 ELECTRICAL PLAN - FOURTH FLOOR OVERALL

100-ED404 ELECTRICAL DEMOLITION PLAN - FOURTH FLOOR

100-ED105 ELECTRICAL PLAN - FIFTH FLOOR OVERALL

100-ED405 ELECTRICAL DEMOLITION PLAN - FIFTH FLOOR

100-ED106 ELECTRICAL PLAN - SIXTH FLOOR OVERALL

100-ED406 ELECTRICAL DEMOLITION PLAN - SIXTH FLOOR

100-ED107 ELECTRICAL PLAN - SEVENTH FLOOR OVERALL

100-ED407 ELECTRICAL DEMOLITION PLAN - SEVENTH FLOOR

100-E100 ELECTRICAL PLAN - LOWER LEVEL FLOOR NEW OVERALL

100-E400A ENLARGED FLOOR PLANS - LOWER LEVEL

100-E400B ENLARGED ELECTRICAL PLAN - LOWER LEVEL FLOOR

100-E101 ELECTRICAL PLAN - FIRST FLOOR NEW OVERALL

100-E401A ENLARGED ELECTRICAL PLAN - FIRST FLOOR

100-E401B ENLARGED ELECTRICAL PLAN - FIRST FLOOR

100-E102 ELECTRICAL PLAN - SECOND FLOOR NEW OVERALL

100-E402 ENLARGED ELECTRICAL PLAN - SECOND FLOOR

100-E103 ELECTRICAL PLAN - THIRD FLOOR NEW OVERALL

100-E403 ENLARGED ELECTRICAL PLAN - THIRD FLOOR

100-E104 ELECTRICAL PLAN - FOURTH FLOOR NEW OVERALL

100-E404 ENLARGED ELECTRICAL PLAN - FOURTH FLOOR

100-E105 ELECTRICAL PLAN - FIFTH FLOOR NEW OVERALL

100-E405 ENLARGED ELECTRICAL PLAN - FIFTH FLOOR

100-E106 ELECTRICAL PLAN - SIXTH FLOOR NEW OVERALL

100-E406 ENLARGED ELECTRICAL PLAN - SIXTH FLOOR

100-E107 ELECTRICAL PLAN - SEVENTH FLOOR NEW OVERALL

100-E407 ENLARGED ELECTRICAL PLAN - SEVENTH FLOOR

100-E200 BONDING AND GROUNDING - LOWER LEVEL NEW WORK

100-E201 BONDING AND GROUNDING - FIRST FLOOR NEW WORK

100-E202 BONDING AND GROUNDING - SECOND FLOOR NEW WORK

100-E203 BONDING AND GROUNDING - THIRD FLOOR NEW WORK

100-E204 BONDING AND GROUNDING - FOURTH FLOOR NEW WORK

100-E205 BONDING AND GROUNDING - FIFTH FLOOR NEW WORK

100-E206 BONDING AND GROUNDING - SIXTH FLOOR NEW WORK

100-E207 BONDING AND GROUNDING - SEVENTH FLOOR NEW WORK

EE500 ELECTRICAL DETAILS

EE501 ELECTRICAL DETAILS

EE502 GROUNDING PLAN

EE600.1 PANELBOARD SCHEDULES

EE600.2 PANELBOARD SCHEDULES

EE600.3 PANELBOARD SCHEDULES

EE600.4 PANELBOARD SCHEDULES

EE601.1 PANELBOARD SCHEDULES

EE601.2 PANELBOARD SCHEDULES

EE601.3 PANELBOARD SCHEDULES

EE601.4 PANELBOARD SCHEDULES

EE602.1 PANELBOARD SCHEDULES

EE602.2 PANELBOARD SCHEDULES

EE602.3 PANELBOARD SCHEDULES

EE603.1 PANELBOARD SCHEDULES

EE603.2 PANELBOARD SCHEDULES

EE603.3 PANELBOARD SCHEDULES

EE604.1 PANELBOARD SCHEDULES

EE604.2 PANELBOARD SCHEDULES

EE604.3 PANELBOARD SCHEDULES

EE605.1 PANELBOARD SCHEUDLES

EE605.2 PANELBOARD SCHEDULES

EE606 PANELBOARD SCHEDULES

EE607 PANELBOARD SCHEDULES

EE700 SINGLE-LINE

EE701 SINGLE-LINE

CONSTRUCTION COR

DANIEL ODA

No. Revisions: Date:

BID DOCUMENTS 01/09/2023

No. Revisions: Date:

BID DOCUMENTS 01/09/2023

5/8" GYPSUM WALLBOARD

- PAINT P-1

3-5/8" 20 GA. COLD-FORMED

STEEL FRAMING

4 7/8"

TYPE 1 (U.N.O.)

ONE LAYER OF 5/8" GYPSUM

WALLBOARD ON EACH SIDE OF

3-5/8" 20 GA. NON STRUCTURAL

METAL FRAMING @ 16" O.C.

HEIGHT VARIES REFER TO

DETAILS.

DEFLECTION CHANNEL

J-BEAD FINISHED EDGE - TYP.

P1

A101

SIM

A101

SIM

A101

SIM

A101

SIM

A B B R E V I A T I O N S

LEVEL NAME W/ ELEVATION

NEW GRID HEAD

CALL OUT HEAD W/ SHEET NUMBER

ROOM NAME W/ ROOM NUMBER, AREA

& OCCUPANCY

BUILDING SECTION NUMBER W/ SHEET

NUMBER

WALL SECTION NUMBER W/

SHEET NUMBER

DOOR NUMBER

WALL TAG

KEYNOTE

REVISION TAG

FINISH TAG

DETAIL SECTION NUMBER W/

SHEET NUMBER

NORTH ARROW

LEVEL

ELEVATION

ROOM NAME

150 SF

S Y M B O L S

WINDOW TAGA

0 EXISTING GRID HEAD

10'-0" CEILING HEIGHT TAG

A.B. ANCHOR BOLT

A.C.M. ASBESTOS CONTAINING MATERIALS

A.C.P. ASPHALT CONCRETE PAVING

A/C AIR CONDITIONING

ACOUS. ACOUSTIC

A.C.T. ACOUSTICAL CEILING TILE

A.D. AREA DRAIN

ADJ. ADJUSTABLE

AFF ABOVE FINISH FLOOR

AGG. AGGREGATE

AL. ALUMINUM

ALT. ALTERNATE

APPROX. APPROXIMATE

ARCH. ARCHITECT

ASPH. ASPHALT

BD. BOARD

BITUM. BITUMINOUS

BLDG. BUILDING

BLK. BLOCK

BLKG. BLOCKING

BM. BENCH MARK OR BEAM

BOT. BOTTOM

BRG. BEARING

BRK. BRICK

BRZ. BRONZE

BTWN. BETWEEN

B.U.R BUILT-UP ROOFING

CAB. CABINET

CARP. CARPET

C.B. CATCH BASIN

C.B.B. CEMENTITIOUS BACKER BOARD

CEM. CEMENT

CER. CERAMIC

CER.T. CERAMIC TILE

C.F.C.I. CONTRACTOR

FURNISH/CONTRACTOR INSTAL

C.F.O.I. CONTRACTOR FURNISH/OWNER

INSTALL

C.HK. COAT HOOK

C.I. CAST IRON

CIR. CIRCLE

C.J. CONSTRUCTION JOINT

CLG. CEILING

CLG.J. CEILING JOINT

CLKG. CAULKING

CLO. CLOSET

CLR. CLEAR

CLS. CLOSURE

CMU CONCRETE MASONRY UNIT

CNTR. COUNTER

C.O. CLEAN OUT

COL. COLUMN

COMB. COMBINATION

COMP. COMPOSITION

CONC. CONCRETE

CONN. CONNECTION

CONST. CONSTRUCTION

CONT. CONTINUOUS

CONV.O. CONVECTION OVEN

C.O.R. CONTRACTING OFFICER'S

REPRESENTATIVE

CTR. CENTER

C.W. COLD WATER

CW. CURTAINWALL

DET. DETAIL

DF. DOUGLAS FIR

D.F. DRINKING FOUNTAIN

DIA. DIAMETER

DIAG. DIAGONAL

DIM. DIMENSION

DISP. DISPOSAL

DIV. DIVISION

DN. DOWN

D.O. DOOR OPENING

DR. DOOR

D.S. DOWN SPOUT

D.T. DRAIN TILE

D.W. DISHWASHER

DWG(S). DRAWING(S)

DWR. DRAWER

(E) EXISTING

EA. EACH

E.C. ELECTRICAL CONTRACTOR

E.E. EACH END

E.F. EXHAUST FAN

E.J. EXPANSION JOINT

ELEC. ELECTRICAL

ELEV. ELEVATION

E.N. EDGE NAIL

ENCL. ENCLOSURE

EQUIV. EQUIVALENT

E.S. EACH SIDE

E.W. EACH WAY

E.W.C. ELECTRICAL WATER CLOSET

EXP. EXPANSION

EXP.B. EXPANSION BOLT

EXPO. EXPOSURE

EXT. EXTERIOR

F. FACE

F.A. FIRE ALARM

F.B. FACE BRICK

F.BD. FIRE BOARD

F.BELL FIRE BELL

F.B.O. FURNISHED BY OTHERS

F.D. FLOOR DRAIN

FDN. FOUNDATION

F.E. FIRE EXTINGUISHER

F.E.C. FIRE EXTINGUISHER CABINET

F.F. FINISH FLOOR

F.G. FINISH GRADE

FGL. FIBERGLASS

F.H. FIRE HYDRANT

FH.M.S. FLAT HEAD MACHINE SCREW

FIN. FINISH

FIXT. FIXTURE

F.J. FLOOR JOIST

F.L. FLOOR LINE

FLASH FLASHING

FLOUR FLUORESCENT

FLR. FLOOR

F.N. FACE NAIL

F.O.B. FACE OF BUILDING

F.O.C. FACE OF CONCRETE

F.O.F. FACE OF FINISH

F.O.M. FACE OF MASONRY

F.O.S. FACE OF STUD

F.R.T.W. FIRE RETARDANT TREATED WOOD

F.S.C. FIRE SUPPRESSION CONTRACTOR

F.S.E.C. FOOD SERVICE EQUIPMENT

CONTRACTOR

FTG. FOOTING

FUT. FUTURE

F.V.C. FIRE VAULT CABINET

GA. GAUGE

GALV. GALVANIZED

G.C. GENERAL CONTRACTOR

G.B. GRAB BAR

G.D. GARBAGE DISPOSAL

G.E. GRATE ELEVATION

G.I. GALVANIZED IRON

GL. GLASS

GLB. GLUE LAMINATED BEAM

GND. GROUND

GR. GRADE

G.S.M. GALVANIZED SHEET METAL

GYP.BD. GYPSUM BOARD

H.B. HOSE BIB

HC. HANDICAPPED

HDR. HEADER

HDWD. HARDWOOD

HDWE. HARDWARE

HGT. HEIGHT

H.M. HOLLOW METAL

HORIZ. HORIZONTAL

H.P. HIGH POINT

HR. HOUR

H.S.S. HOLLOW STRUCTURAL STEEL

HTG. HEATING

H.V.A.C. HEATING, VENTILATION & AIR

CONDITIONING

H.W. HOT WATER

I.D. INSIDE DIAMETER

INSUL. INSULATION

INT. INTERIOR

INV. INVERT

JAN. JANITOR

J.H. JOIST HANGER

JST. JOIST HANGER

JT. JOINT

KIT. KINTCHEN

LAB LABORATORY

LAM. LAMINATE

LAV. LAVATORY

L.B. LAG BOLT

L.H. LEFT HAND

L.L. LIVE LOAD

L.P. LOW POINT

LT. LIGHT

MAT. MATERIAL

MAX. MAXIMUM

M.B. MACHINE BOLT

M.C. MEDICINE CABINET

MECH. MECHANICAL

MED. MEDIUM

MEMB. MEMBRANE

M.E.P. MECHANICAL, ELECTRICAL,

PLUMBING

MFG. MANUFACTURER

MH. MANHOLE

MIN. MINIMUM

MIR. MIRROR

MISC. MISCELLANEOUS

M.O. MASONRY OPENING

MOD. MODULAR

MP.H. MOP HOLDER

MR. FRAMED MIRROR

M.R. MOISTURE RESISTANT

M.T. METAL THRESHOLD

MTD. MOUNTED

MTL. METAL

(N) NEW

N. NORTH

NAT. NATURAL

N.I.C. NOT IN CONTRACT

(NOT PART OF OSA APPROVAL)

NO. NUMBER

NOM. NOMINAL

NON/COM NON-COMBUSTIBLE

N.T.S. NOT TO SCALE

O/ OVER

O.A. OVERALL

OBS. OBSCURE

O.C. ON CENTER

O.D. OUTSIDE DIAMETER

O.F. OVERFLOW

OFF. OFFICE

O.F.S. OUTSIDE FACE OF STUD

O.H.W.S. OVAL HEAD WOOD SCREW

OPP. OPPOSITE

P. PAINT

P.C. PLUMBING CONTRACTOR

P.C.F. POUNDS PER CUBIC FOOT

P.E.N. PANEL EDGE NAILING

PERF. PERFORATED

PL. PLATE

P.LAM PLASTIC LAMINATE

PLAS. PLASTER

P.L.F. POUNDS PER LINEAR FOOT

PLYWD. PLYWOOD

P.M.F. PRESSED METAL FRAME

PR. PAIR

PROP. PROPERTY

P.S.F. POUNDS PER SQUARE FOOT

P.S.I. POUNDS PER SQUARE INCH

P.STA. PULL STATION

PTD. PAINTED

P.T.D. PAPER TOWEL DISPENSER

PT. POINT

P.T.D.F. PRESSURE TREATED DOUGLAS

FIR

PTN. PARTITION

P.T.R. PAPER TOWEL RECEPTACLE

P.V.C. POLYVINYL-CHLORIDE

Q.T. QUARRY TILE

RAD. RADIUS

R.B. RUBBER BASE

R.C.P. REFLECTED CEILING PLAN

R.D. ROOF DRAIN

RDWD. REDWOOD

REF. REFERENCE

REFR. REFRIGERATOR

REINF. REINFORCING

REQD. REQUIRED

RESIL. RESILIENT

R.H. ROOF HATCH

R.HK. ROBE HOOK

R.H.M.S. ROUND HEAD METAL SCREW

R.H.W.S. ROUND HEAD WOOD SCREW

RM. ROOM

R.O. ROUGH OPENING

R.W.L. RAIN WATER LEADER

S. SOUTH

S.A.B. SOUND ATTENUATION BATT

S.A.D. SEE ARCHITECTURAL DRAWINGS

S.A.F.F. SELF ADHERED FLEXIBLE FLASHING

S.A.S.M. SELF ADHERED FLEXIBLE MEMBRANE

S.BLKG. SOLID BLOCKING

SCWD. SOLID CORE WOOD DOOR

S.C.D. SEE CIVIL DRAWINGS

S.D. STORM DRAIN

S.DISP. SOAP DISPENSER

SEAL. SEALANT

SECT. SECTION

S.E.D. SEE ELECTRICAL DRAWINGS

SHR. SHOWER

SHT. SHEET

SHTG. SHEATHING

SIM. SIMILAR

SL. SLIDING

S.L.D. SEE LANDSCAPE DRAWINGS

S.M.D. SEE MECHANICAL DRAWINGS

S.N.D. SANITARY NAPKIN DISPOSAL

S.N.V. SANITARY NAPKIN DISPENSER

S.P. SOUNDPROOF

SPEC. SPECIFICATION

SQ. SQUARE

SQ.FT. SQUARE FOOT (FEET)

S.S. SANITARY SEWER

S.S.D. SEE STRUCTURAL DRAWINGS

STA. STATION

STD. STANDARD

STL. STEEL

S.STL. STAINLESS STEEL

STO. STORAGE

STRUC. STRUCTRUAL

SUSP. SUSPENDED

T.B. TACKBOARD

T&B. TOP AND BOTTOM

TEL. TELEPHONE

TEMP. TEMPERED

TER. TERRAZZO

T&G. TOUNGE AND GROOVE

THK. THICK

T.J. TOOL JOINT

T.N. TOE NAIL

T.O.C. TOP OF CURB

T.O.P TOP OF PAVEMENT

T.O.PL. TOP OF PLATE

T.O.S. TOP OF SEAT

T.O.W. TOP OF WALL

T.P.D. TOILET PAPER DISPENSER

T.S. TUBE STEEL

T.V. TELEVISION

TYP. TYPICAL

UNF. UNFINISHED

U.N.O. UNLESS NOTED OTHERWISE

UR. URINAL

U/S. UNDERSIDE

V.C.T. VINYL COMPOSITION TILE

VERT. VERTICAL

VEST. VESTIBULE

V.G. VERTICAL GRAIN

V.I.F. VERIFY IN FIELD

V.T. VINYL TILE

V.T.R. VENT TO ROOF

V.W.C. VINYL WALL COVERING

(VC) V.A. FURNISHED / CONTRACTOR

INSTALLED

(VV) V.A. FURNISHED AND INSTALLED

W. WEST

W/ WITH

W/IN WITHIN

W.C. WATER CLOSET

WD. WOOD

WDW. WINDOW

W.F. WATER COOLER

W.H. WATER HEATER

W/O WITHOUT

W.P. WATER PROOF

W.R. WATER RESISTANT

WT. WEIGHT

W.W.F. WELDED WIRE FABRIC

YD. YARD

LOCATION

F I N I S H S C H E D U L E

MATERIAL BASIS OF DESIGN COLOR

ARMSTRONG EXCELON

PPG

PPG

PPG

MASONITE ASPIRO SERIES

C.O.R. TO SELECT COLOR

MATCH ADJACENT WALLS

MACH ADJACENT FRAMES

WHITE

SOLID CORE DOOR/WOOD VENEER.

RED OAK (PLAIN SLICED), CLEAR

FLOORING/ BASE IN TR

PAINT, P-1

PAINT, P-2

PAINT, P-3

DOORS

FLOORING/ BASE IN TR

WALL PAINT - ALL NEW GYPSUM/CMU

ALL NEW DOOR FRAMES

ALL NEW PLYWOOD

DOOR SLAB

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:1

:4

P

M

100-GI001

SCHEDULES, PARTITION TYPES

AND ABBREVIATIONS

01/09/2023 PH NM

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTS

JOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

1. TYPICAL PARTITION TYPE IS WALL TYPE "1" UNLESS NOTED OTHERWISE ON PLAN.

2. BUILD PARTITIONS IN ACCORDANCE WITH PARTITION SCHEDULE AND DESIGN REFERENCED.

REFERENCES ARE TO LATEST EDITION OF GYPSUM ASSOCIATION (GA) FIRE RESISTANCE DESIGN

MANUAL, OR TO UNDERWRITERS LABORATORY (UL) FIRE RESISTANCE DIRECTORY.

3. ALL WALLBOARD IS TO BE TYPE "X" UNLESS NOTED OTHERWISE.

4. PARTITION TYPES INDICATED ARE CONTINUOUS TO A CORNER OR AN INTERSECTING PARTITION, UNLESS INDICATED OTHERWISE. WHERE PARTITIONS OF DIFFERENT THICKNESSES MEET, MAINTAIN A FLUSH SURFACE ON THE SIDE WHERE FACES ARE STRAIGHT AND CONTINUOUS, UNLESS NOTED

OTHERWISE.

5. METAL STUD GAUGES SCHEDULED ARE THE MINIMUM REQUIRED, AND MAY BE INCREASED BY

SPECIFICATIONS TO ACCOMMODATE LOADS, FINISHES, OR UNBRACED CEILING HEIGHT LIMITS. DO

NOT CONSIDER CEILING SYSTEM(S) AS A PARTITION BRACING ELEMENT.

6. WOOD AND PLYWOOD BLOCKING TO BE FIRE RETARDANT TREATED (FRT).

7. EDGES OF GYPSUM WALL BOARD (GWB) LEFT EXPOSED TO VIEW, OR ABUTTING DISSIMILAR

MATERIAL, IS TO BE FINISHED WITH METAL "L" BEAD TRIM AND COMPOUND UNLESS NOTED

OTHERWISE.

8. PARTITION SCHEDULE IS BASED ON THE USE OF GYPSUM WALL BOARD (GWB), BUT FACING BOARD

MAY VARY, DEPENDENT ON FINAL FINISH SCHEDULED FOR THAT PARTITION.

9. ALL FIRE RATED WALL AND FLOOR PENETRATION MUST COMPLY WITH ASTM-E814

10. ALL DOOR OPENINGS SHALL BE 4" FROM A PERPENDICULAR PARTITION TO OUTSIDE FACE OF FRAME, UNLESS NOTED OR DETAILED OTHERWISE.

11. ALL PARTITIONS, INCL. STUDS, BOARD, ETC. TO EXTEND FROM TOP OF FLOOR SLAB TO UNDERSIDE

OF CONCRETE SLAB ABOVE UNLESS OTHERWISE NOTED.

12. CONTRACTOR IS TO CLOSE OFF ANY VOIDS LEFT AS A RESULT OF ANY REMOVALS AND NEW CONSTRUCTION, AS WELL AS INFILL ANY EXISTING VOIDS IN NEWLY DESIGNATED FIRE RATED PARTITIONS. ALL PATCHES SHALL MATCH AND ALIGN WITH SURROUNDING MATERIALS AND SHALL BE

IN ACCORDANCE WITH NFPA CODE.

13. REFER TO NEW ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE DESIGNATIONS.

14. CONTRACTOR SHALL SEAL PARTITION WALLS AROUND ALL M.E.P. PENETRATIONS OR OPENINGS, RESULTING FROM M.E.P. INSTALLATIONS INCLUDING BUT NOT LIMITED TO THE SLAB, ABOVE AND

BELOW CEILINGS.

15. ALL NEW MASONRY WORK INCLUDING NEW PARTITIONS, INFILL AND PATCHING; MATCH EXISTING

COURSING AND TOOTH IN WITH EXISTING ADJ. CONSTRUCTION.

16. NO EXISTING FIREPROOFING IS TO BE REMOVED FROM EXISTING BUILDING STRUCTURE FOR ANY

NEW INSTALLATION FOR ANY REASON.

17. ALL INTERIOR PARTITIONS ARE TO BE CONSTRUCTED FROM FLOOR TO DECK, AND ALL

PENETRATIONS SEALED. THIS INCLUDES SEALING ABOUT PIPE/DUCT/CONDUIT PENETRATIONS. THE METHOD OF SEALING THE PENETRATIONS SHALL BE CONSISTENT WITH THE RATING – IF ANY – OF

THE WALL.

18. LABEL ALL RATED PARTITIONS (FIRE & SMOKE) ABOVE THE CEILING, ON BOTH SIDES OF THE WALL.

G E N E R A L N O T E S

DOOR SCHEDULE

MARK HEIGHT WIDTH THICKNESS NOTES

A1026A 7' - 0" 3' - 0" 0' - 1 3/4"

A1115A 7' - 0" 3' - 0" 0' - 1 3/4"

A2031A 7' - 0" 3' - 0" 0' - 1 3/4"

A2140A 7' - 0" 3' - 0" 0' - 1 3/4"

A3031A 7' - 0" 3' - 0" 0' - 1 3/4"

A3142A 7' - 0" 3' - 0" 0' - 1 3/4"

A4075A 7' - 0" 3' - 0" 0' - 1 3/4"

A4144A 7' - 0" 3' - 0" 0' - 1 3/4"

A5031A 7' - 0" 3' - 0" 0' - 1 3/4"

A5144A 7' - 0" 3' - 0" 0' - 1 3/4"

A6031 7' - 0" 3' - 0" 0' - 1 3/4"

A6142A 7' - 0" 3' - 0" 0' - 1 3/4"

A7031A 7' - 0" 3' - 0" 0' - 1 3/4"

A7042A 7' - 0" 3' - 0" 0' - 1 3/4"

B1230A 7' - 0" 3' - 0" 0' - 1 3/4"

B1340B 7' - 0" 3' - 0" 0' - 1 3/4"

B2239A 7' - 0" 3' - 0" 0' - 1 3/4"

B2359A 7' - 0" 3' - 0" 0' - 1 3/4"

B3239A 7' - 0" 3' - 0" 0' - 1 3/4"

B3361A 7' - 0" 3' - 0" 0' - 1 3/4"

B4223A 7' - 0" 3' - 0" 0' - 1 3/4"

B4355A 7' - 0" 3' - 0" 0' - 1 3/4"

B5239A 7' - 0" 3' - 0" 0' - 1 3/4"

B5378A 7' - 0" 3' - 0" 0' - 1 3/4"

C1514A 7' - 0" 3' - 0" 0' - 1 3/4"

C1671A 7' - 0" 3' - 0" 0' - 1 3/4"

C1772A 7' - 0" 3' - 0" 0' - 1 3/4"

C1884A 7' - 0" 3' - 0" 0' - 1 3/4"

C1999DA 7' - 0" 3' - 0" 0' - 1 3/4" 1

C2465A 7' - 0" 3' - 0" 0' - 1 3/4"

C2571A 7' - 0" 3' - 0" 0' - 1 3/4"

C2741A 7' - 0" 3' - 0" 0' - 1 3/4"

C2981A 7' - 0" 3' - 0" 0' - 1 3/4"

C3554A 7' - 0" 3' - 0" 0' - 1 3/4"

C3676A 7' - 0" 3' - 0" 0' - 1 3/4"

C3747A 7' - 0" 3' - 0" 0' - 1 3/4"

C3841A 7' - 0" 3' - 0" 0' - 1 3/4"

C4483A 7' - 0" 3' - 0" 0' - 1 3/4"

C4654A 7' - 0" 3' - 0" 0' - 1 3/4"

C4763A 7' - 0" 3' - 0" 0' - 1 3/4"

C4967A 7' - 0" 3' - 0" 0' - 1 3/4"

ECM07A 7' - 0" 3' - 0" 0' - 1 3/4" 1

LL050A 7' - 0" 3' - 0" 0' - 1 3/4"

LL210A 7' - 0" 3' - 0" 0' - 1 3/4"

LL212A 7' - 0" 3' - 0" 0' - 1 3/4" 1

LL411A 7' - 0" 3' - 0" 0' - 1 3/4"

LL530A 7' - 0" 3' - 0" 0' - 1 3/4"

LL554A 7' - 0" 3' - 0" 0' - 1 3/4"

LL659A 7' - 0" 3' - 0" 0' - 1 3/4"

LL775A 7' - 0" 3' - 0" 0' - 1 3/4"

Grand total: 50

DOOR SCHEDULE NOTES

1. EXISTING DOOR - REMOVE AND REINSTALL FOR NEW PACS; REFER TO ELECTRICAL

DRAWINGS.

2. ALL NEW DOORS ARE HARDWARE SET HW-SH-3D

3. ALL NEW DOOR SLABS ARE SOLID CORE WOOD

4. ALL NEW FRAMES ARE HOLLOW METAL - PAINT P-2

REMOVE EXISTING CHAIN LINK FENCE.

REPLACE WITH WALL AND DOOR.

EXAMPLE SCOPE OF WORK

A7031 ELECTRICAL CLOSET C3554 TR ROOM

NEW MOUNTED PAINTED 3/4" FIRE-RETARDANT

TREATED PLYWOOD

NEW CEILING MADE OF FIRE-RETARDANT

TREATED PLYWOOD AND COLD-FORMED

STEEL FRAMING.

REFER TO SPECIFIC PLANS AND DETAILS

C3554 ELECTRICAL CLOSET A7031 TR ROOM

REMOVE EXISTING PAINT IN ELECTRICAL CLOSET

AND INSTALL ELECTRICAL DISSIPATING TILE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:1

:4

P

M

100-GI002

EXISTING CONDITIONS

01/09/2023 NM PH

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTS

JOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

C O D E A N A L Y S I S

ITEM DESCRIPTION CODE REFERENCE

OCCUPANCY: HEALTH CARE1.

1-2 HOSPITALS

2. NO CHANGE TO EXISTING BUILDING AREA

NUMBER OF EXISTING STORIES:3. ABOVE GRADE: 14 (INCLUDING

INTERSTITIAL SPACES) BELOW GRADE: 1

CONSTRUCTION TYPE: I (332)4.

SPRINKLER SYSTEM:6.

EXISTING NFPA 13 SPRINKLER SYSTEM INSTALLED THROUGHOUT

RENOVATIONS ARE TO ALSO BE SPRINKLED THROUGHOUT, ADDITION

TO BE SPRINKLED.

FIRE ALARM SYSTEMS:7.

1-2 HOSPITALS

TRAVEL DISTANCE TO EXIT ACCESS DOOR FROM WITHIN A SUITE:8.

100 FT. THROUGH ONE INTERVENING ROOM

50 FT. THROUGH TWO INTERVENING ROOMS

TRAVEL DISTANCE TO AN EXIT FROM WITHIN A SUITE

200 FT.

OPENING PROTECTION IN FIRE RATED SMOKE BARRIERS:9.

DOORS: 45 MIN. IN 1HR RATED WALLS GENERAL

60 MIN. IN 1HR RATED WALLS FOR STAIRS

WINDOWS: 45 MIN. IN 1HR RATED WALLS GENERAL

NOT PERMITTED IN 1HR RATED WALLS FOR STAIRS

100 SQ. IN. MAX FOR WINDOWS IN DOORS FOR 60 MIN. DOORS

MAINTAIN EXISTING 2 HOUR FLOOR/ CEILING RATING AS AFFECTED BY

DEMOLITION AND NEW WORK.

10.

EXISTING:

LIFE SAFETY: 6.1

LIFE SAFETY: 19.1.6.4 &

18.1.6.4

LIFE SAFETY: 9.7.1.1

LIFE SAFETY: 9.6

LIFE SAFETY: 8.3.4.2

DEAD END CORRIDORS: 30' MAX11. LIFE SAFETY:

18.2.5.2

AREAS TO BE SEPARATED:12.

BOILER ROOMS - 1 HOUR

SOILED LINEN - 1 HOUR

STORAGE ROOMS >/= 100 S.F. - 1 HOUR

SMOKE BARRIER - 1 HOUR

CLEAN LINEN - 1 HOUR

SMOKE COMPARTMENT SIZE - 22,500 S.F. MAX

SEE PLANS FOR EXISTING FIRE WALLS

LIFE SAFETY:

18.4.5.5.1

A P P L I C A B L E C O D E S A N D S T A N D A R D S

APPLICABLE CODES

BUILDING CODES: EDITION:

INTERNATIONAL BUILDING CODE 2021

NFPA 101 LIFE SAFETY CODE 2021

NFPA 220 STANDARD ON TYPES OF BUILDINGS 2021

BARRIER FREE CODES:

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS

WITH THE DEPARTMENT OF VETERANS AFFAIRS BARRIER

FREE DESIGN GUIDE ( A SUPPLEMENT)

ELECTRICAL CODE:

NATIONAL ELECTRIC CODE NFPA 70 2020

FIRE PREVENTION CODE:

NFPA 1: UNIFORM FIRE CODE

CONSTRUCTION TYPE:

TYPE 1A/ I (332) (FULLY SPRINKLED)

STRUCTURAL MEMBER HR RATING

EXTERIOR BEARING WALLS 3

INTERIOR BEARING WALLS 3

COLUMNS 3

BEAMS, GIRDERS & TRUSSES 3

FLOOR-CEILING ASSEMBLIES 2

ROOF-CEILING ASSEMBLIES 1.5

INTERIOR NONBEARING WALLS 0

EXTERIOR NONBEARING WALLS 0

FIRE PROTECTION:

GROUP I-2

STANDARD FOR THE INSTALLATION OF

SPRINKLER SYSTEM: NFPA 13 2019

THE NORMAL APPLICATION OF MULTIPLE CODES, WITH DIFFERING REQUIREMENTS, IS TO USE THE MOST RESTRICTIVE. IN THIS SUMMARY, NFPA 101 IS THE PRIMARY CODE. THE IBC IS ONLY USED WHEN NFPA 101

IS SILENT ON THE SUBJECT MATTER.

THE CODE SUMMARY IS BASED ON THE FOLLOWING CRITERIA:

1. EXISTING BUILDING AND ADDITION IS TO BE SPRINKLED THROUGHOUT.

2. EXISTING HOSPITAL MEETS NFPA 101, CHAPTER 19 - EXISTING HEALTHCARE OCCUPANCIES AND THE

NEW ADDITION MEETS NFPA 101 CHAPTER 18 - HEALTHCARE OCCUPANCIES.

F I R E C O D E R A T I N G/ S Y M B O L S

1-HR. SMOKE BARRIER

EXISTING 1-HR. SMOKE BARRIER

1-HR. FIRE RATED WALL

EXISTING 1-HR. FIRE RATED WALL

2-HR. FIRE RATED WALL

EXISTING 2-HR. FIRE RATED WALL

EXIT (#=OCCUPANT LOAD)

FIRE EXTINGUISHER CABINET

FEC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:1

:4

P

M

100-GI003

CODE ANALYSIS

01/09/2023 PH NM

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTSJOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

DN

DN

OFFICE

LL191

OFFICE

LL193

CONFERENCE

ROOM

LL171

BREAK

ROOM

LL172

OFFICE

LL174

OFFICE

LL176

OFFICE

LL180

OFFICE

LL182

OFFICE

LL181

OFFICE

LL179

OFFICE

LL177

OFFICE

LL196

OFFICE

LL194

OFFICE

LL192

OFFICE

LL186

CORRIDOR

CLL27CORRIDOR

CLL26

CORRIDOR

CLL28

OFFICE

LL183

OFFICE

LL184

STORAGE

LL187

TOILET

LL185

CLOSET

LL184A

CONTROLED

DRUGS

LL104

PHARMACY

VAULT

LL105

STORAGE

LL107

H.A.C.

LL103

NON-HAZARDOUS

BUFFER

AREA

LL101A

HAZARDOUS

BUFFER

AREA

LL102A

ANTE

LL102

CLEAN

ROOM

LL101

STORAGE

LL106 PHARMACY

LL109

CORRIDOR

CLL24

PHARMACY

LL100

PHARMACY

LL100A

OFFICE

LL115

OFFICE

A7116

OFFICE

A7118

OFFICE

LL117

RESEARCH

LAB

LL119

OFFICE

LL127

WOMENS

TOILET

LL129A

WOMENS

LOCKERS

LL129

MENS

LOCKERS

LL128

MENS

TOILET

LL128A

LOUNGE

LL126

OFFICE

LL124

PHARMACY

LL111

ELECTRICAL

LL108

EXAM

LL020

CONSULATION

ROOM

LL058

MRI ROOM

LL059

SIMULATION

ROOM

LL061

TOILET

LL062

TREATMENT

CONTROL

ROOM

LL066

TREATMENT

ROOM

LL067

CAST BLOCK

ROOM

LL054

COMPUTER

ROOM

LL056

ELECTRICAL

LL050

CORRIDOR

CLL12

WOMENS

TOILET

LL028

MENS

TOILET

LL030

LAB

LL053

SEALED

SOURCE

ROOM

LL055

RADIATION

THERAPY

LL026

SOILED

UTILITY

LL027

CLEAN

UTILITY

LL025

H.A.C.

LL023

OFFICE

LL021

OFFICE

LL039

OFFICE

LL037

OFFICE

LL035

OFFICE

LL033

STORAGE

LL032

LOUNGE

LL034

OFFICE

LL036

OFFICE

LL038

OFFICE

LL040

CORRIDOR

CLL08

STORAGE

LL013

TOILET

LL015

EXAM

LL017

EXAM

LL019

CORRIDOR

CLL19

CORRIDOR

CLL17

CHANGING

ROOM

LL063

LOCKERS

LL064

CHANGING

ROOM

LL065

CORRIDOR

CLL05

STORAGE

LL012

CLERK

LL011

WAITING

LL010

CORRIDOR

CLL09

CORRIDOR

CLL10

STORAGE

XXX

ELEVATOR

#07

TREATMENT

ROOM

LL068

STAIR #02

SLL02

CORRIDOR

LL123

CORRIDOR

CLL15

CORRIDOR

CLL16

CORRIDOR

CLL13

CORRIDOR

CLL11

CORRIDOR

CLL14

CORRIDOR

CLL29

CORRIDOR

CLL07

TR

LL050A

CART LIFT

#03

SA102j

MECHANICAL

LL052

PHARMACY

CAGE

LL109A

AREA WELL

SA102k

CONFERENCE

LL219

SOILED

UTILITY

LL340

OFFICE

LL242

OFFICE

LL235

OFFICE

LL236

OFFICE

LL237OFFICE

LL238

STORAGE

LL239

OFFICE

LL220

CORRIDOR

CLL48

STORAGE

LL225

COMPUTER

ROOM

LL228

SERVER

ROOM

LL246

ELECTRICAL

LL247

STORAGE

LL300

OFFICE

LL302

OFFICE

LL303

STORAGE

LL301

LAB

LL308

COMPRESSOR

ROOM

LL309

WALK-IN

FRIDGE

LL310

OFFICE

LL311

OFFICE

LL312

OFFICE

LL313

OFFICE

LL314

OFFICE

LL315

OFFICE

LL316

STORAGE

LL317

STORAGE

LL318

UTILITY

ROOM

LL319

LAB

LL320

LAB

LL321

LAB

LL322

LAB

LL323

LAB

LL324

LAB

LL325

LAB

LL326

LAB

LL327

LAB

LL328

CORRIDOR

CLL58

CORRIDOR

CLL59

CORRIDOR

CLL67

CORRIDOR

CLL68

LAB

LL330

LAB

LL333

H.A.C.

LL334

ANIMAL

HOUSING

LL342

ANIMAL

HOUSING

LL343

ANIMAL

HOUSING

LL344

CAGE

STORAGE

LL345

ANIMAL

HOUSING

LL346

ANIMAL

HOUSING

LL347

ANIMAL

HOUSING

LL348

ANIMAL

HOUSING

LL349

ANIMAL

HOUSING

LL350

ANIMAL

HOUSING

LL351

ANIMAL

HOUSING

LL352

ANIMAL

HOUSING

LL353

LOUNGE

LL355

CORRIDOR

CLL65

CORRIDOR

CLL64

CORRIDOR

CLL62

ANIMAL

HOUSING

LL370

CORRIDOR

CLL71

OFFICE

LL357

OFFICE

LL358

LAB

LL359

LAB

LL360

LAB

LL361

LAB

LL362

LAB

LL363

FOOD/BEDDING

LL364

LOCKER

LL365

STORAGE

LL366

LOCKER

LL367

KITCHEN

LL364A

WALK-IN

FRIDGE

LL364B TOILET

LL365A

TOILET

LL367A

ANIMAL

HOUSING

LL372

LOCKER

LL374

TOILET

LL374A

CORRIDOR

CLL77

LAB

LL376

LAB

LL378

LAB

LL380

LAB

LL379

CART LIFT

LL381

WOMENS

LOCKER

LL382

TOILET

LL382A

CORRIDOR

CLL74

CORRIDOR

CLL75

CORRIDOR

CLL73

MENS

LOCKER

LL384

STORAGE

LL385

UTILITY

ROOM

LL388

OPERATING

ROOM

LL389

UTILITY

ROOM

LL390

OPERATING

ROOM

LL391

H.A.C.

LL392

LAB

LL394

LAB

LL396

OFFICE

LL398

KITCHEN

LL398A

STAIR #06

SLL06

LAB

LL402

REFRIGERATOR

LL402A

LAB

LL404

CLEAN

UTILITY

ROOM

LL399

ANIMAL

CAGE

WASHER

LL400

STORAGE

LL340ACORRIDOR

CLL70

CORRIDOR

CLL72

LAB

LL406

STORAGE

LL407

H.A.C.

LL408

COMPRESSOR

ROOM

LL409

LAB

LL410

ELECTRICAL

LL411

MECHANICAL

LL412

CART LIFT

#06

AREA WELL

TOILET

LL384A

TR

LL411A

STORAGE

LL500 HAZARDOUS

WASTE

LL501

EMS

RECEIVING

LL504

OXYGEN

STORAGE

LL502

EMS

STORAGE

LL505 EMS

STORAGE

LL503 ELECTRICAL

LL511

STORAGE

LL509

STORAGE

LL507

STORAGE

LL508

STORAGE

LL510COMPRESSOR

ROOM

LL506

CORRIDOR

CLL83

CORRIDOR

CLL82

MECHANICAL

LL528

STAIR #08

SLL08

CORRIDOR

CLL99

ELECTRICAL

LL530

TOILET

LL520

OFFICE

LL521

OFFICE

LL523

VAULT

LL524

CLOSET

LL525

COMPRESSOR

ROOM

LL527

STAIR #12

SLL12WALK-IN

REFRIGERATOR

LL526

LOADING

DOCK

LL518

CORRIDOR

CLL84SOILED

LINEN

LL514

STORAGE

LL512

CLEAN LINEN

LL515

STORAGE

LL513

MECHANICAL

LL556

ELECTRICAL

LL554

CORRIDOR

CLL98

STAIR #09

SLL09

TOILET

LL553A

TOILET

LL551A

LOCKERS

LL551

LOCKERS

LL553

CLEAN

RECEIVING

LL549

OFFICE

LL545

ELEVATOR

ROOM

LL547

CART LIFT

#07

WAREHOUSE

STORAGE

LL517

WAREHOUSE

STORAGE

LL516

OFFICE

LL637

OFFICE

LL635

OFFICE

LL634

OFFICE

LL636

CONFERENCE

ROOM

LL638

STORAGE

LL621

H.A.C.

LL620

STORAGE

FLAMMABLE

LL656

PAINT SHOP

LL653

OFFICE

LL654

STAIR #10

SLL10

SPRAY

BOOTH

LL652

MECHANICAL

LL670

CORRIDOR

CLL97

MECHANICAL

LL658

ELECTRICAL

LL659

OFFICE

LL671

OFFICE

LL651

ELECTRIC

SHOP

LL650

OFFICE

LL648

OFFICE

LL647

OFFICE

LL646 OFFICE

LL645

OFFICE

LL644

OFFICE

LL640

OFFICE

LL643

TOILET

LL641

TOILET

LL675

PLOTER

ROOM

LL639

CORRIDOR

CLL89

OFFICE

LL633

CONFERENCE

LL623

MECHANICAL

LL776

STAIR #11

SLL11

ELECTRICAL

LL775

CORRIDOR

CLL96STAIR #13

SLL13

FILE ROOM

LL772

OFFICE

LL770

OFFICE

LL769

H.A.C.

LL812

SHOWER

LL813

TOILET

LL814

OFFICE

LL815

CORRIDOR

CLL109

OFFICE

LL820

OFFICE

LL821

OFFICE

LL822

OFFICE

LL823

OFFICE

LL831

CONFERENCE

ROOM

LL836

KITCHEN

LL807

STORAGE

LL806STORAGE

EQUIPMENT

LL805

ARMORY

LL804

EVIDENCE

LL803 CORRIDOR

CLL107

CORRIDOR

CLL108

OFFICE

LL824

OFFICE

LL825

WAITING

LL827

CORRIDOR

CLL106

COMPUTER

ROOM

LL830

HOLDING

LL802

OFFICE

LL801

DISPATCH

LL800

CARPENTER

SHOP

LL672

MECHANICAL

/ PIPE SHOP

LL673

FLIGHT OPS

LL676

OFFICE

LL674

STORAGE

EQUIPMENT

LL682

BIOMEDICAL

ENGINEERING

SHOP

LL678

OFFICE

LL679

H.A.C.

LL680

OFFICE

LL681

CART LIFT

#08

CORRIDOR

CLL87

LOCKERS

LL607

TOILET

LL607A

LOUNGE

LL540

CHANGING

ROOM

LL606

LOCKERS

LL608

TOILET

LL608A

H.A.C.

LL610 STORAGE

LL604

MSD

STORAGE

LL548

SPS

LL546

SPS

RECEPTION

LL544

CORRIDOR

CLL88

CORRIDOR

CLL86

PREP ROOM

LL558

GAS ROOM

LL559

OFFICE

LL600

WASH BAY

LL601

H.A.C.

LL603

DECONTAMINATION

ROOM

LL605

WASHING

MECHANICAL

LL602

MAIL ROOM

LL686

REPRODUCTION

ROOM

LL692

OFFICE

LL695

OFFICE

LL693

OFFICE

LL691

OFFICE

LL689

OFFICE

LL687

CORRIDOR

CLL93

CORRIDOR

CLL91

CORRIDOR

CLL105

OFFICE

LL712

OFFICE

LL700

STORAGE

LL771

ELEVATOR

MACHINE

ROOM

LL768

H.A.C.

LL767

TOILET

LL766

OFFICE

LL765

WAITING

LL763

CORRIDOR

CLL94

OFFICE

LL764

OFFICE

LL761

OFFICE

LL760

LOUNGE

LL762

OFFICE

LL750

CORRIDOR

CLL92

OFFICE

LL740

OFFICE

LL738

LOCKERS

LL811

ELECTRIC

SHOP

LL682A

LOUNGE

LL678A

LOCKSMITH

LL805A

MEDICAL

SUPPLY

LL550

TR

LL775A

TR

LL659ATR

LL554A

TR

LL530A

IT STORAGE

LL519

CORRIDOR

CLL676

OFFICE

LL165

OFFICE

LL164

MECHANICAL

LL215

CORRIDOR

CLL30

AUDITORIUM

LL200

STORAGE

LL203

ELECTRICAL

LL210ELECTRICAL

LL212

ELECTRICAL

LL214

STAIR #05

SLL05

TOILET

LL216A

SWITCHBOARD

LL216

STORAGE

LL202

STORAGE

LL204

AUDITORIUM

SUPPORT

LL205

CORRIDOR

CLL32

STORAGE

LL198

STORAGE

LL199

STAIR #04

SLL04

CORRIDOR

CLL33

STORAGE

LL206

WOMENS

TOILET

LL207

MENS

TOILET

LL208

ELECTRICAL

ROOM - I.T.

HUB

LL218

CORRIDOR

CLL81

CORRIDOR

CLL51

CORRIDOR

CLL41

CORRIDOR

CLL31

CORRIDOR

CLL21

CORRIDOR

CLL03

AUDITORIUM

STAGE

LL201

CORRIDOR

CLL35

CORRIDOR

CLL34

CORRIDOR

CLL37

CORRIDOR

CLL25

CORRIDOR

CLL23

CORRIDOR

CLL45

CORRIDOR

CLL53

CORRIDOR

CLL60

LOUNGE

LL304

OFFICE

LL305

STORAGE

LL306

CORRIDOR

CLL50

CLASS

ROOM

LL271

STORAGE

LL273

CORRIDOR

CLL43

H.A.C.

LL276

Room

LL274A

CONFRENECE

LL254

OFFICE

LL256

OFFICE

LL258

LOUNGE

LL257

OFFICE

LL255

STORAGE

LL261

STORAGE

EQUIPMENT

LL260CORRIDOR

CLL40

SUPPLY

ROOM

LL262

TOILET

LL268

TOILET

LL265

COMPRESSOR

ROOM

LL266

STORAGE

LL263

CORRIDOR

CLL61

CART LIFT

#05

ELEVATOR

LOBBY

CLL52

LOCKERS

LL267

CORRIDOR

CLL46

LOCKERS

LL267A

SHOWERS

LL267B

EQUIPMENT

LL264A

CORRIDOR

CLL44

LOCKERS

LL264

SHOWERS

LL264B

OFFICE

LL259

OFFICE

CLERK

LL250

LOCKERS

LL278

TOILET

LL278A

LOCKERS

LL280

TOILET

LL280A

CORRIDOR

CLL42

AUTOPSY

LL274

FREEZER

LL272

VIEWING

ROOM

LL270

MECHANICAL

LL002

CORRIDOR

CLL02

ELEVATOR

LOBBY

CLL04

CORRIDOR

CLL01

STORAGE

LL008

TOILET

LL004A

TOILET

LL006A

CLEAN LINEN

LL003

ANTE

LL004

ANTE

LL006

CORRIDOR

CLL20

SOILED

UTILITY

LL007

CART LIFT

#01

A8006CART LIFT

#02

A8007

H.A.C.

LL154

MISC.

KITCHEN

LL155

MECHANICAL

LL156

KITCHEN

STORAGE

LL148

STORAGE

LL147

H.A.C.

LL146

KITCHEN

LL145

KITCHEN

LL142

KITCHEN

LL143

KITCHEN

LL141

H.A.C.

LL140

KITCHEN

LL144

KITCHEN

LL159

KITCHEN

STORAGE

LL151

KITCHEN

STORAGE

LL150WALK-IN

FREEZER

LL149

KITCHEN

LL153

KITCHEN

LL152

KITCHEN

LL157

KITCHEN

LL158

COMPRESSOR

ROOM

LL160

ELEVATOR

#11

A8008

ELEVATOR

#12

A8009

ELEVATOR

#14

A8010

ELEVATOR

#13

A8011

SERVICE

ELEVATOR

#16

A8012

SERVICE

ELEVATOR

#15

A8013

ELEVATOR

#10

A8014

ELEVATOR

#09

A8015

ELEVATOR

#08

A8016

ELEVATOR

#03

A8017

ELEVATOR

#04

A8018

ELEVATOR

#01

A8019

ELEVATOR

#02

A8020

SERVICE

ELEVATOR

#05

A8021

SERVICE

ELEVATOR

#06

A8022

STAIR #07

SLL07

STAIR #01

SA001

TR

LL210A

GROUND

MAINTENANCE

GARAGE

ECL01

OFFICE

ECL01A

H.A.C.

ECL02

TOILET

ECL03

TOILET

ECL04

UTILITY

ROOM

ECL05

PUMP ROOM

ECL06

SOIL CART

STAGING

ECL07

MECHANICAL

ROOM

ECL08

TRASH

RECEIVING

ECL09

PUMP ROOM

ECL06A

STORAGE

ECL11

WASH

ECL07A

CORRIDOR

ECCL1

CORRIDOR

CECL2

STAIR

EC103-3

STAIRS

EC103-2

STAIRS

EC103-1

STORAGE

ECL10

ELEVATOR

#3

E03

ELEVATOR

#2

E02

FUTURE

ELEVATOR

E01

STAIR #01

NPS01

ELEVATOR

PIT

NP002

STAIR #05

NPS05

THERMAL

STORAGE

TANK

XXX

PIPE

GALLERY

LL495

ELEVATOR

#3

E03

ELEVATOR

#2

E02

ELEVATOR

#1

E01

100-AD400

100-AD400

100-AD400

100-AD400

100-AD400

100-AD400

100-AD400

100-AE400A

100-AD400

100-AE400

100-AE400

100-AE400

100-AE400

100-AE400

100-AD400A

100-AE400

100-AE400

100-AE400

ZONE 1ZONE 2ZONE 3ZONE 4

ZONE 5ZONE 6

ZONE 7ZONE 8

ZONE 9ZONE 10

ZONE 13

BLDG 103

BLDG 100

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:1

:3

P

M

100-AE100

OVERALL LOWER LEVEL FLOOR

PLAN

01/09/2023 PH NM

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTS

JOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

N

1/32" = 1'-0"

OVERALL LOWER LEVEL FLOOR PLAN

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

ELECTRICAL

LL050

TR

LL050A

4' - 4"

ELECTRICAL

LL210

TR

LL210A

ELECTRICAL

LL214

ELECTRICAL

LL212

ELECTRICAL

LL411

TR

LL411A

4' - 4"

ELECTRICAL

LL530

TR

LL530A

ELECTRICAL

LL554

TR

LL554A

ELECTRICAL

LL659

TR

LL659A

ELECTRICAL

LL775

TR

LL775A

LL775:

https://my.matterport.com/show/?m=mucr8LmvRyi

LL659:

https://my.matterport.com/show/?m=m4LmLp9YCiA

LL210:

https://my.matterport.com/show/?m=yZMjFjYk1L2

LL050:

https://my.matterport.com/show/?m=ukqnroHWwV6

LL212:

https://my.matterport.com/show/?m=VNNY1uD6mwm

LL411:

https://my.matterport.com/show/?m=4RSUK9A1VRp

LL214:

https://my.matterport.com/show/?m=6h5aWvtGGJY

LL530:

https://my.matterport.com/show/?m=wDP5BfK3E1n

LL554:

https://my.matterport.com/show/?m=wP3vEGUzDCo

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRICAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:1

:3

P

M

100-AD400

LOWER LEVEL DEMOLITION

PLANS

01/09/2023 PH NM

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTS

JOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL050 - ZONE 1

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL210 - ZONE 6

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL214 - ZONE 6

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL411 - ZONE 4

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL530 - ZONE 10

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL554 - ZONE 10

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL659 - ZONE 9

N

1/4" = 1'-0"

DEMO LOWER LEVEL LL775 - ZONE 9

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

D R A W I N G N O T E S :

1 DEMOLISH EXISTING CHAIN LINK GATE.

2 DEMOLISH PORTION OF CMU WALL AS INDICATED.

3 REMOVE EXISTING PAINT FROM FLOOR AND PREPARE FLOOR FOR ELECTRICAL DISSIPATING FLOOR TILE.

4 EXISTING MOUNTED PLYWOOD TO REMAIN, TYPICAL.

5 REMOVE AND REPLACE FRAME AND LOCKSET AS REQUIRED FOR CARDREADER. REUSE REMAINING HARDWARE.

6 EXISTING DIAGONAL STRUCTURAL BRACING.

2D /1

V

2D /1

V

2D /1

V

2D /1

V

4D

2D/1V

2D/1V

1D /1

V

2D/1V

ELECTRICAL

LL247

OFFICE

LL242

SERVER ROOM

LL246

A246:

https://my.matterport.com/show/?m=XCvUA55443v

A. MASONRY WALLS BETWEEN TR ROOMS AND ELECTRICAL ROOMS ARE APPROXIMATELY 12' TALL.

B. CEILINGS IN ELECTRICAL AND TR ROOMS ARE APPROXIMATELY 20' TALL.

G E N E R A L D E M O L I T I O N N O T E S:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

A u to d e s k D o c s

/D e tr o it V

A M

C

E H

R M

I n fr a s tr u c tu re /F

F E

D e tr o it

E H

R M

A

R C

H rv t

/1

/2

:1

:4

P

M

100-AD400A

LOWER LEVEL DEMOLITION

PLANS

01/09/2023 PH NM

EHRM INFRASTRUCTURE

UPGRADES - DETROIT, MI

553-21-701

DETROIT, MICHIGAN

BID DOCUMENTS

JOHN D.

DINGELL VA

MEDICAL

CENTER

Approved: Owner

N

1/4" = 1'-0"

DEMO LOWER LEVEL COMPUTER ROOM - ZONE 3

D R A W I N G N O T E S :

1 EXISTING 1-HOUR FIRE BARRIER.

2 EXISTING RAISED FLOOR IN ROOM - WORK TBD.

3 REMOVE EXISTING HOLLOW METAL WIRE GLASS WINDOWS.

KEY PLAN

South Parking Deck

BLDG

North Parking Deck

BLDG

BLDG 103

8 7

2 1

EM

E M

EM

EM

CR

EM

EM

EM

E M

EM

CR

EM

EM

EM

EM

EM

EM

EM

EM

CR

EM

EM

EM

EM

EM

EM

EM

CR

EM

EM

E M

EM

EM

EM

EM

E M

E M

CR

EM

E M

CR

EM

EM

EM

EM

EM

EM

E M

C R

EM

EM

EM

EM

E M

EM

EM

CR

E M

EM

E M

EM

TR

LL530A

ELECTRICAL

LL530

L L A

ELECTRICAL

LL554

TR

LL554A

L L A

TR

LL659A

ELECTRICAL

LL659

L L A

ELECTRICAL

LL775

TR

LL775A

L L A

ELECTRICAL

LL411

TR

LL411A

L L A

ELECTRICAL

LL214

ELECTRICAL

LL212

2 3

L L A

ELECTRICAL

LL210

TR

LL210A

LL210A

ELECTRICAL

LL050

TR

LL050A

L L A

LL775:

https://my.matterport.com/show/?m=mucr8LmvRyi

LL659:

https://my.matterport.com/show/?m=m4LmLp9YCiA

LL210:

https://my.matterport.com/show/?m=yZMjFjYk1L2

LL050:

https://my.matterport.com/show/?m=ukqnroHWwV6

LL212:

https://my.matterport.com/show/?m=VNNY1uD6mwm

LL411:

https://my.matterport.com/show/?m=4RSUK9A1VRp

LL214:

https://my.matterport.com/show/?m=6h5aWvtGGJY

LL5…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .