This document is an appendix containing the bill of materials for demountable walls and doors required by the federal contract opportunity solicitation number FA481423TF122 for furniture for PKB-J6 and J2 at USSOCOM. The salient characteristics include semipermanent STC45 rated wall systems installed as equipment connecting to the false ceiling grid and carpeted floor to provide full height, sound attenuating office walls and doors. Wall covering is 6MIL vinyl in "Dungee Grey" with darker grey metal trim. Walls must accommodate electrical outlets and network wiring with vertical/horizontal raceways. Doors specified are 30/70 solid core with satin mahogany finish and surface mounted bottoms. The bill of materials lists the manufacturer, quantities, part numbers, descriptions and optional descriptions for the demountable walls and doors required under several contract line items, including 71' of walls under CLIN 1, 44' of walls and 2 doors under CLIN 2, 110' of walls under CLIN 4, 35' of walls and 2 doors under CLIN 5, and 25' of walls and 1 door under CLIN 6.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Appendix B, Salient Characteristics & Bill of Materials

Salient Characteristics & Bill of Materials for Demountable Walls with Doors — E2, Series 338 (or Equal)

To be considered “equal”, offered products must meet the following salient functional, physical and/or performance characteristics:

Semi‐permanent STC45 rated wall systems, installed as equipment, connecting to the false ceiling grid and the carpeted floor to provide full height, sound attenuating office walls and doors.

Ceiling tracks and floor runners connect to existing infrastructure without causing damage.

Requires sound seals on all ceiling tracks, at all wall intersections and around all wall jambs.

Wall covering is 6MIL vinyl, “Dungee Grey”. Metal trim shall be a darker grey.

Walls shall accommodate electrical outlets and network wiring with vertical/horizontal raceways.

Where doors are specified: 3‐0/7‐0 solid core door with satin mahogany finish and surface mounted door bottoms.

CLIN 1: 501‐1107

Manufacturer Qty Part # Part Desc Opt Desc

E2 71'

SERIES

Demountable

Walls INSTALLED

CLIN 2: 501‐2214

Manufacturer Qty Part # Part Desc Opt Desc

E2 44’

SERIES

Demountable

Walls INSTALLED

E2 2

SERIES

338 3-0/7-0 Door solid core door w/ satin mahogany finish

CLIN 4: 501‐2246

E2 110’ SERIES

Demountable Walls INSTALLED

Appendix B, Salient Characteristics & Bill of Materials

CLIN 5: 5014‐247

E2 35’ Series 338 Demountable

Walls INSTALLED

E2 2

SERIES

338 3-0/7-0 Door solid core door w/ satin mahogany

CLIN 6: 5015‐237

E2 25’

SERIES

Demountable

Walls INSTALLED

E2 1 SERIES

3-0/7-0 Door solid core door w/ satin mahogany