Attachment 3_Conceptual Architecture Plans.pdf

PDF 947 KB Posted

Attached to
Southernwood Primary School Renovation, South Africa
Solicitation number
W912GB23R0002
Issued by

About this file

This announcement solicits design-build proposals for the renovation of a primary school facility in South Africa. The U.S. Army Corps of Engineers, Europe District seeks a single contractor to complete 100% design and construction. Interested offerors must attend a mandatory site visit on November 8th and pre-register attendees by November 4th. Non-price and price proposals are due by the time specified in the solicitation. Offerors must be registered in the System for Award Management to be eligible for award. The renovation scope includes classroom, office, and storage spaces according to the conceptual plans provided.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

16 m²

STORAGE

65 m²

CLASSROOM

8.

m

3 3 3

2.50 m

8.05 m

3 3

A-101

A-1013 FIN. FLOOR

0.00 m

ROOF

2.80 m

GRADE

-0.10 m

7 3 3

FIN. FLOOR

0.00 m

ROOF

2.80 m

GRADE

-0.10 m

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-101

1- C

LA

SS

R O

O M

S C

H O

O L

BU

IL

D

IN

G

So ut he rn w oo d Pr im ar y Sc ho ol

Ea st

L on do n, E as te rn

C ap e, S ou th

A fri ca

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

BA

LL

N

AT

H

BU

SH

# NOTE

1 CHALK BOARD

2 PIN BOARD

3 EXTERIOR WINDOW WITH SECURITY BARS.

4 EXTERIOR DOOR WITH SECURITY GATE.

5 INTERIOR DOOR WITH SECURITY GATE.

7 WALL-MOUNTED SWING TYPE FIRE HOSE REEL

WITH 30 METER HOSE AND NOZZLE

8 METAL SHELVING

9 FIRE EXTINGUISHER (9 kg MINIMUM) AND WALL

MOUNTED BRACKET

NOTES:

1.DIMENSIONS ARE APPROXIMATE. CONTRACTOR MUST VERIFY

SITE CONDITIONS AND PROVIDE A DESIGN THAT MEETS ALL

REQUIREMENTS OF THE SOW.

2. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING

CONDITIONS AND PREPARING A DESIGN THAT IS COMPATIBLE

WITH THE EXISTING TOPOGRAPHY.

M

AR

K D

E S C

R

IP

TI

O

N D

AT

E

NTSA-101

1 1-CLASSROOM SCHOOL BUILDING

NTSA-101

2 1-CLASSROOM FRONT ELEVATION

NTSA-101

3 1-CLASSROOM SIDE ELEVATION

8 m²

OFFICE

7 m²

STORAGE

57 m²

CLASSROOM

57 m²

CLASSROOM

8 m²

STORAGE

8 m²

STORAGE

57 m²

CLASSROOM

8.

m

3 3 3 3 3 3 3 3

4 4 4

2.50 m 7.38 m2.50 m

9 9 9

8 8

7.09 m7.09 m

33 3

33 33

26.80 m

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-102

3- C

LA

SS

R O

O M

S C

H O

O L

BU

IL

D

IN

G

So ut he rn w oo d Pr im ar y Sc ho ol

Ea st

L on do n, E as te rn

C ap e, S ou th

A fri ca

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

BA

LL

N

AT

H

BU

SH

1 : 50A-102

1 3-CLASSROOM SCHOOL BUILDING

NOTES:

1.DIMENSIONS ARE APPROXIMATE. CONTRACTOR MUST VERIFY

SITE CONDITIONS AND PROVIDE A DESIGN THAT MEETS ALL

REQUIREMENTS OF THE SOW.

2. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING

CONDITIONS AND PREPARING A DESIGN THAT IS COMPATIBLE

WITH THE EXISTING TOPOGRAPHY.

M

AR

K D

E S C

R

IP

TI

O

N D

AT

E

0 0.5 2.5 m

1:50

SCALE

# NOTE

1 CHALK BOARD

2 PIN BOARD

3 EXTERIOR WINDOW WITH SECURITY BARS.

4 EXTERIOR DOOR WITH SECURITY GATE.

5 INTERIOR DOOR WITH SECURITY GATE.

7 WALL-MOUNTED SWING TYPE FIRE HOSE REEL

WITH 30 METER HOSE AND NOZZLE

8 METAL SHELVING

9 FIRE EXTINGUISHER (9 kg MINIMUM) AND WALL

MOUNTED BRACKET

FIN. FLOOR

0.00 m

ROOF

2.80 m

GRADE

-0.12 m

FIN. FLOOR

0.00 m

ROOF

2.80 m

GRADE

-0.12 m

US Army Corps of Engineers ®

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

AW

N

B Y:

D

ES

IG

N

ED

B

Y:

SU

BM

IT

TE

D B

Y:

SI

ZE

C H

EC

KE

D B

Y:

AN

SI

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

A-103

EL

EV

AT

IO

N S

So ut he rn w oo d Pr im ar y Sc ho ol

Ea st

L on do n, E as te rn

C ap e, S ou th

A fri ca

EU

R O

PE

D

IS

TR

IC

T

W

IE

SB

AD

EN

, G

ER

M

AN

Y

D es ig ne r

Au th or

C he ck er

M

AR

K D

E S C

R

IP

TI

O

N D

AT

E

1 : 50A-103

1 FRONT ELEVATION

1 : 50A-103

2 SIDE ELEVATION

NOTES:

1.DIMENSIONS ARE APPROXIMATE. CONTRACTOR MUST VERIFY

SITE CONDITIONS AND PROVIDE A DESIGN THAT MEETS ALL

REQUIREMENTS OF THE SOW.

2. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING EXISTING

CONDITIONS AND PREPARING A DESIGN THAT IS COMPATIBLE

WITH THE EXISTING TOPOGRAPHY.

0 0.5 2.5 m

1:50

SCALE

Sheets
A-101 - 4-CLASSROOM SCHOOL BUILDING
ar162_1-Classroom Building.pdf
Sheets
A-101 - 1-CLASSROOM SCHOOL BUILDING
ar162_3-Classroom Building.pdf
Sheets
A-102 - 3-CLASSROOM SCHOOL BUILDING
ar162_3-Classroom Building_Elevations.pdf
Sheets
A-103 - ELEVATIONS

File details come from the government source that posted it. Updated .