ATTACHMENT 3 Architectural Drawings.pdf

PDF 2 MB Posted

Attached to
Construct Masons Clinic - South Africa
Solicitation number
W912GB22R0031
Issued by

About this file

This solicitation announcement is for design and construction services for the construction of Masons Clinic in Copesville, Pietermaritzburg, South Africa. The US Army Corps of Engineers, Europe District is soliciting proposals for a design-build project and intends to award a single contract to a design-build construction contractor who will complete the 100% design and construction of the project. Interested offerors must submit both a non-price proposal for evaluation and a price proposal by the date specified in the solicitation posted with this announcement. Offerors must be registered in the US System for Award Management to be eligible for award. The online industry presentation on the USACE Europe District website provides detailed information on registration, understanding solicitations, and construction work for USACE.

View the file

Other files

File Type Posted
W912GB22R0031_0003 Amendment Signed.pdf PDF
ATTACHMENT 2 - AMENDED Concept Site Plan _ ar164_Att 2_Conceptual Site Plan_Mod.01.pdf PDF
ATTACHMENT 7 - AMENDED Statement of Work _ ar164 011010 - amendment 1.pdf PDF
ATTACHMENT 16 - ar164_Att 6_Municipal Sewer Manhole Location Map_Mod.01.pdf PDF
W912GB22R0031_0003 Modification Summary of Changes.pdf PDF
W912GB22R0031_0002_Amendment_Signed.pdf PDF
W912GB22R0031_0001_Amendment.pdf PDF
W912GB22R0031_0001_Amendment_Signed.pdf PDF
ATTACHMENT 10 Commitment Letters.docx DOCX document
ATTACHMENT 8 Bank Letter of Assurance (BLA) Template_New.docx DOCX document
ATTACHMENT 5 Dedication Plaque.pdf PDF
ATTACHMENT 13 VAT Information.docx DOCX document
W912GB22R0031_Construct Masons Clinic_South Africa.pdf PDF
ATTACHMENT 7 Statement of Work (SOW).pdf PDF
ATTACHMENT 14 Pay Terms Bid Schedule-Price Schedule.docx DOCX document
ATTACHMENT 4 Structural calculations Guideline.pdf PDF
ATTACHMENT 15 Site Visit Attendee Worksheet.xlsx XLSX spreadsheet
ATTACHMENT 9 Bank Letter of Guarantee (BLG) Template.docx DOCX document
ATTACHMENT 2 Concept Site Plan.pdf PDF
ATTACHMENT 12 Experience Information Sheet.docx DOCX document
ATTACHMENT 6 SPECIFICATIONS BINDER.pdf PDF
ATTACHMENT 1 Project Location Map.pdf PDF
ATTACHMENT 11 Past Performance Questionnaire.docx DOCX document
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2.

1.

1.

1.

1.

7.0 m²

GAS STORAGE

6.1 m²

MED. WASTE

5.3 m²

GEN. WASTE

5.3 m²

GARDEN STOR.

5.3 m²

LAUNDRY

3.50

OPEN FOR

MAXIMUM

VENTILATION

14.5 m²

DIRTY UTILITY

17.5 m²

PROCEDURE

19.9 m²

EMERGENCY

ROOM

4.3 m²

HANDICAPPED

PATIENTS TOILETS

15.6 m²

HALLWAY

12.8 m²

LINEN

6.5 m²

CLEANER

STORAGE

4.4 m²

STAFF TOILET

4.4 m²

STAFF SHOWER

16.6 m²

STAFF BREAK

ROOM

37.2 m²

LOBBY

44.7 m²

SUB WAITING

17.3 m²

COUNCELLING

8.2 m²

VITALS

16.0 m²

CONSULTATIONS

16.0 m²

CONSULTATIONS

16.0 m²

CONSULTATIONS

5.7 m²

HALLWAY

13.5 m²

HALLWAY

20.9 m²

OPEN BREEZEWAY

5.9 m²

SPUTUM BOOTH

5.9 m²

SPUTUM BOOTH

mop sink urinals

.3

22.97

4.37 8.95 4.00

3.

4.

4.

1.

2.

1.

1.

1.

2.

4.37

2.37

4.69

2.73 2.73

3.95

2.33 1.50

1.80

3.

2.

4.

4.

3.

2.

3.

1.

1.

1.

2.

1.

1.

1.

1.

2.

4.

1.5 m²

WC

1.5 m²

WC

1.5 m²

WC

1.5 m²

WC

3.8 m²

WC HC

1.5 m²

WC

1.5 m²

WC

11.1 m²

TOI. MALE

10.1 m²

TOI. FEMALE

7.

4.

recessed floor mat 2 x 2 meter

< concrete apron and roof overhang

< concrete apron and roof overhang stainless steel > wash basin

< ventilation wall openings ventilation wall openings >

RHW

LEGEND:

RHW = ROOM HIGH WINDOW

RHW

RHW

RHW RHW

RHW

RHW

RHW

RHW

RHW

RHW

RHW

RHW

Mason Clinic Floor Plan (NOT TO SCALE)

Waste Building Floor Plan

(NOT TO SCALE)

1.

1.00

1.001.00

1.

1.

00 1.00

3.06

1.00

1.00

1.

1.00 concrete apron and roof overhang > roof overhang 50cm roof overhang 50cm roof overhang 50cm

1.00

U S

A rm y C o rp s o f E n g in ee rs

S H

E E

T I

D

US ARMY CORPS OF ENGINEERS

DRAWN BY:

DESIGNED BY:

SUBMITTED BY:

SIZE:

CHECKED BY:

ANSI D

ISSUE DATE:

CONTRACT

NO.:

SOLICITATION NO.:

G

FEDCBA

DATEMARK DESCRIPTION

A -1

1 GROUND FLOOR PLAN

KwaZulu-Natal Province, Copesville, Pietermaritzburg, 3201

EUROPE DISTRICT

WIESBADEN, GERMANY

M. BALLNATH

M. BALLNATH

T. BUSH

FIRST TITLE

SECOND TITLE

D E

S

IG

N -B

U

ILD

S O

LIC

IT

A T

IO

N

MASON CLINIC

PROJECT # 35746

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

N

0 1 5 m

1:100

SCALE

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N

O

S O

LI

C

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

A-104

R O

O F

P

LA

N

K w aZ ul u- N at al

P ro vi nc e, C op es vi lle

, P ie te rm ar itz bu rg

, 3

E U

R O

P E

D

IS

T R

IC

T

W

IE

S B

A D

E N

, G E

R M

A N

Y

M .B

A

LL

N A

T H

M .B

A

LL

N A

T H

T .B

U S

H

F

IR

S T

T

IT

LE

S E

C O

N D

T

IT

LE

DESIGN-BUILD SOLICITATION

M A

S O

N C

LI

N

IC

P R

O

JE

C T

NOTE: DRAWINGS ARE PROVIDED FOR REFERENCE ONLY. THE CONTRACTOR

IS RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS. THE

CONTRACTOR IS RESPONSIBLE FOR PROVIDING A DESIGN THAT MEETS ALL

APPLICABLE CODES AND THE REQUIREMENTS OF THE STATEMENT OF WORK.

N

0 1 5 m

1:100

SCALE

E7EDGMCB

Typewritten Text

NOT TO SCALE

Floor Plans (USACE Floor Plan)
00_G. FLOOR PLAN
Mason Clinic Roof Plan 251120201030.pdf
3D Views
{3D}

File details come from the government source that posted it. Updated .