Attachment 3 504-23-106 Contract Drawings.pdf
PDF 28 MB Posted
- Solicitation number
- 36C25724B0016
About this file
This document appears to be a set of contract drawings related to Solicitation Number 36C25724B0016 for the project "Z2FZ--37C25724B0016, 504-23-106 Renovate Swing Space, Amarillo, TX 79106". The solicitation was issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17 for the renovation of swing space in Amarillo, Texas. The solicitation is for construction services, though the specific scope of work is not detailed in this attachment. No additional details regarding response dates, award dates, pricing terms, set asides, incumbents, or other salient information are provided in this document, as it appears to be solely the contract drawings.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AREA OF WORK
LOCATION FOR TEMPORARY STORAGE
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI001
COVER RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
12 & 44
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
THOMAS E CREEK VAMC
6010 W AMARILLO BLVD, AMARILLO, TX 79106
VAMC PROJECT #: 504-23-106
RENOVATE FOR SWING SPACE
SHEET NUMBER SHEET NAME
GENERAL
GI001 COVER
GI002 GENERAL ABBREVIATIONS, NOTES, & SYMBOLS
GI003 ACCESSIBILITY STANDARDS
GI111 LIFE SAFETY PLAN - BUILDING 12 - LEVEL 1
GI112 LIFE SAFETY PLAN - BUILDING 44 - LEVEL 1
GI113 LIFE SAFETY PLAN - BUILDING 44 - LEVEL 2
GI121 DEPARTMENTAL PLANS
GI911 POST BLDG 4 CONSTRUCTION PLAN - BUILDING 12 -
LEVEL 1
GI913 POST BLDG 4 CONSTRUCTION PLAN - BUILDING 44 -
LEVEL 2
HAZARDOUS MATERIALS
HA111 ASBESTOS ABATEMENT PLAN - BUILDING 12 - LEVEL 1
STRUCTURAL
S-001 STRUCTURAL NOTES
S-601 INSPECTION SCHEDULES 2021 IBC
SF132 ROOF PLAN - BUILDING 44
ARCHITECTURAL
A-001 ARCHITECTURAL ABBREVIATIONS, NOTES, & SYMBOLS
AD111 DEMOLITION PLAN - BUILDING 12 - LEVEL 1
AD112 DEMOLTION PLAN - BUILDING 44 - LEVEL 1
AD113 DEMOLTION PLAN - BUILDING 44 - LEVEL 2
AD132 DEMOLITION PLAN - ROOF - BUILDING 44
AS101 SITE PLAN
AS111 SITE PLAN - BUILDING 12
AE111 FLOOR PLAN - BUILDING 12 - LEVEL 1
AE112 FLOOR PLAN - BUILDING 44 - LEVEL 1
AE113 FLOOR PLAN - BUILDING 44 - LEVEL 2
AE121 REFLECTED CEILING PLAN - BUILDING 12 - LEVEL 1
AE122 REFLECTED CEILING PLAN - BUILDING 44 - LEVEL 1
AE131 ROOF PLAN - BUILDING 12
AE132 ROOF PLAN - BUILDING 44
AE141 FINISH PLAN - BUILDING 12 - LEVEL 1
AE151 FURNITURE PLAN - BUILDING 12 - LEVEL 1
AE152 FURNITURE PLAN - BUILDING 44 - LEVEL 1
AE201 EXTERIOR ELEVATIONS
AE411 ENLARGED PLANS
AE601 PARTITION TYPE SCHEDULES
AE611 DOOR & WINDOW SCHEDULES AND DETAILS
AE641 ROOM FINISH SCHEDULE
FIRE PROTECTION
F-001 FIRE ALARM LEGENDS, NOTES, AND SYMBOLS
F-002 FIRE SUPPRESSION LEGENDS, NOTES, AND SYMBOLS
FA111 FIRE ALARM PLAN - BUILDING 12 - LEVEL 1
FA112 FIRE ALARM PLAN - BUILDING 44 - LEVEL 1
FA113 FIRE ALARM PLAN - BUILDING 44 - LEVEL 2
FX121 FIRE SUPPRESSION RCP - BUILDING 12 - LEVEL 1
FX122 FIRE SUPPRESSION RCP - BUILDING 44 - LEVEL 1
FX123 FIRE SUPPRESSION RCP - BUILDING 44 - LEVEL 2
PLUMBING
P-001 PLUMBING ABBREVIATIONS, SYMBOLS, & LEGENDS
PQ601 EQUIPMENT & FIXTURE SCHEDULES
PD111 PLUMBING DEMOLITION PLAN - BUILDING 12 - LEVEL 1
PD112 PLUMBING DEMOLITION PLAN - BUILDING 44 - LEVEL 2
PP111 DOMESTIC WATER PLAN - BUILDING 12 - LEVEL 1
PP112 DOMESTIC WATER PLAN - BUILDING 44 - LEVEL 2
PW111 DRAIN-WASTE-VENT PLAN - BUILDING 12 - LEVEL 1
PW112 DRAIN-WASTE-VENT PLAN - BUILDING 44 - LEVEL 2
PK501 TYPICAL DETAILS
PK901 DOMESTIC WATER & DWV RISER DIAGRAM - BUILDING
12 - LEVEL 1
SHEET INDEXRENDERED IMAGEAREA OF WORK
SHEET NUMBER SHEET NAME
MECHANICAL
M-001 MECHANICAL ABBREVIATIONS & NOTES
M-002 MECHANICAL SYMBOLS
MQ601 EQUIPMENT SCHEDULES
MD111 MECHANICAL DEMOLITION PLAN - BUILDING 12 - LEVEL
MH111 HVAC PLAN - BUILDING 12 - LEVEL 1
MH112 HVAC PLAN - BUILDING 44 - LEVEL 1
MH113 HVAC PLAN - BUILDING 44 - LEVEL 2
MH114 HVAC PLAN - BUILDING 44 - ROOF
MP111 PIPING PLAN - BUILDING 12 - LEVEL 1
MP112 PIPING PLAN - BUILDING 44 - LEVEL 2
MP113 PIPING PLAN - BUILDING 44 - ROOF
MI111 CONTROLS & INSTRUMENTATION PLAN - BLDG 12 -
LEVEL 1
MI112 CONTROLS & INSTRUMENTATION PLAN - BLDG 44 -
LEVEL 1
MI113 CONTROLS & INSTRUMENTATION PLAN - BLDG 44 -
LEVEL 2
MI114 CONTROLS & INSTRUMENTATION PLAN - BLDG 44 -
ROOF
MI600 CONTROLS & INSTRUMENTATION DETAILS
MK301 MECHANICAL SECTIONS - BLDG 12
MK302 MECHANICAL SECTIONS - BLDG 44
MK501 TYPICAL DETAILS
MK502 TYPICAL DETAILS
MK503 TYPICAL DETAILS
MK504 TYPICAL DETAILS
MK901 MECHANICAL RISER DIAGRAM - BUILDING 12
MK902 MECHANICAL RISER DIAGRAM - BUILDING 44
ELECTRICAL
E-001 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
E-002 ELECTRICAL SYMBOLS
ED111 DEMOLITION PLAN - BUILDING 12 - LEVEL 1
ED113 DEMOLITION PLAN - BUILDING 44 - LEVEL 2
ED121 DEMOLITION RCP - BUILDING 12 - LEVEL 1
ED122 DEMOLITION RCP - BUILDING 44 - LEVEL 1
EL121 LIGHTING RCP - BUILDING 12 - LEVEL 1
EL122 LIGHTING RCP - BUILDING 44 - LEVEL 1
EL131 LIGHTING CONTROLS RCP - BUILDING 12 - LEVEL 1
EL132 LIGHTING CONTROLS RCP - BUILDING 44 - LEVEL 1
EL601 LIGHTING SCHEDULES
EP111 POWER PLAN - BUILDING 12 - LEVEL 1
EP112 POWER PLAN - BUILDING 44 - LEVEL 1
EP113 POWER PLAN - BUILDING 44 - LEVEL 2
EP114 POWER PLAN - BUILDING 44 - ROOF
EP601 ELECTRICAL SCHEDULES
EP602 ELECTRICAL SCHEDULES
EP603 POWER ONE-LINE DIAGRAM
ET111 TELECOM PLAN - BUILDING 12 - LEVEL 1
ET112 TELECOM PLAN - BUILDING 44 - LEVEL 1
ET113 TELECOM PLAN - BUILDING 44 - LEVEL 2
EK501 TYPICAL DETAILS
EK502 TYPICAL DETAILS
N or th
BUILDING 12
BUILDING 44
Number: Revision: Date:
0 100% CONSTRUCTION DOCUMENTS 10/11/2023
ROOM NAME
VIEW TITLE EXAMPLE
ELEVATION CALLOUT EXAMPLE
ENLARGED CALLOUT EXAMPLE
SECTION CALLOUT EXAMPLE
SECTION OR DETAIL SYMBOL IDENTIFIERS
DETAIL NAME
DRAWING NUMBER
DESIGNATOR ON SHEET
DRAWING SEQUENCE
NUMBER INDICATES
WHERE DRAWING IS
LOCATED
TWO CHARACTER
DISCIPLINE DESIGNATOR
AE101
TO OBJECT
CENTER
COLUMN
BUBBLE
ROOM TAG
MATCH LINE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
DETAIL NUMBER
ON SHEET
SHEET NUMBER
NEW LINE TYPE
EXISTING LINE TYPE
DEMOLITION LINE TYPE
AREA OF DEMOLITION
VIEW NAME
1/8" = 1'-0"
AE101
AE101
AS101
SYMBOLS LEGEND
AE101
EXTERIOR
INTERIOR
## SHEET KEYNOTE
REVISION TAG
DRAWING SCALE
REFERENCE
KEYNOTE
DETAIL NUMBER
ON SHEET
SHEET NUMBER
######-A######-A
TO OBJECT
FACE OR OTHER
GEOMETRY
EXTENT OF FUTURE ROOM
1-HR FIRE
2-HR FIRE
3-HR FIRE
4-HR FIRE
1-HR FIRE/SMOKE
2-HR FIRE/SMOKE
3-HR FIRE/SMOKE
4-HR FIRE/SMOKE
0-HR SMOKE 0.5-HR SMOKE
GENERAL ABBREVIATIONS
ABBREVIATIONS LISTED BELOW ARE GENERAL ABBREVIATIONS ACROSS ALL DISCIPLINES. DISCIPLINE SPECIFIC ABBREVIATIONS MAY SUPERSEDE GENERAL ABBREVIATIONS. REFER TO DISCIPLINE SPECIFIC ABBREVIATIONS SHEETS. A. WORK SHALL CONFORM WITH PROJECT SPECIFICATIONS.
B. CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS
RELATED TO THE WORK. QUESTIONS WILL BE DIRECTED TO VHA COR.
C. CONTRACTOR WILL BE SOLELY RESPONSIBLE FOR THE MEANS, METHODS
AND SEQUENCES OF CONSTRUCTION AND THE SAFETY OF CONSTRUCTION
PERSONNEL AND VISITORS.
D. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP
DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS
WILL BE REJECTED AND RETURNED TO THE CONTRACTOR. REFER TO
SPECIFICATION SECTION 01 33 23.
E. EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE WORK WILL
BE INSTALLED AND REPORT TO THE VHA COR, IN WRITING, CONDITIONS
DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THEIR WORK. DO
NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED.
COMMENCING WITH INSTALLATION WILL CONSTITUTE ACCEPTANCE OF THE
SUBSTRATE AND/OR CONDITIONS.
F. DO NOT SCALE DRAWINGS: FOLLOW WRITTEN DIMENSIONS AND NOTES.
CONTACT VHA COR FOR CLARIFICATIONS, IF REQUIRED.
G. "TYPICAL", AS USED IN THESE DOCUMENTS, MEANS THAT THE CONDITION OR
DIMENSION IS REPRESENTATIVE OF, OR THE SAME, FOR SIMILAR
CONDITIONS THROUGHOUT.
H. IF THERE IS A DISCREPANCY BETWEEN SMALL SCALE AND LARGE SCALE
DRAWINGS, (PLAN, SECTION, & DETAIL DRAWINGS, ETC), CONTACT VHA CO
FOR CLARIFICATION.
I. IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, SPECIFICATIONS GOVERN. CONTACT VHA CO FOR
CLARIFICATION.
J. DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL CONDITIONS SHALL
BE REPORTED TO THE VHA CO, IN WRITING, FOR RESOLUTION PRIOR TO
PROCEEDING WITH THE WORK.
K. DISCREPANCIES SHALL BE REPORTED TO THE VHA CO IN WRITING FOR
RESOLUTION, PRIOR TO PROCEEDING WITH THE WORK. NO CHANGE
ORDERS OR EXTENSIONS OF TIME WILL BE ALLOWED OR ACCEPTED FOR
PROCEEDING WITH THE WORK WITHOUT THE CONTRACTING OFFICER'S
WRITTEN DIRECTION AND APPROVAL. ALSO, CONTRACTOR SHALL REPAIR
AND/OR REPLACE UNAUTHORIZED WORK, AS INDICATED BY THE VHA COR,
AT NO ADDITIONAL COST TO THE VHA.
L. DISSIMILAR METAL MATERIALS SHALL BE ISOLATED WITH AN APPROVED
NONMETAL ISOLATION MATERIAL IN ACCORDANCE WITH SPECIFICATIONS.
M. EXTERIOR EXPOSED STEEL SHALL BE PAINTED PER SPECIFICATION SECTION
09 91 00.
N. CONTRACTOR SHALL VERIFY THE LOCATIONS OF EXISTING UNDERGROUND
UTILITIES AND THEIR SERVICE CONNECTIONS WITH THE PROPER UTILITY
COMP, COORDINATE ISSUES WITH VHA COR.
O. CONTRACTOR SHALL COORDINATE SIZE, LOCATIONS AND NUMBER OF ROOF
OPENINGS AND ROOF ACCESSORIES WITH OTHER TRADES. REFER TO THE
ARCHITECTURAL, STRUCTURAL, PLUMBING, MECHANICAL AND ELECTRICAL
DRAWINGS FOR REFERENCE AND SPECIFICATIONS FOR REQUIREMENTS.
P. LOCATIONS AND SIZES OF CONCRETE MECHANICAL AND ELECTRICAL
EQUIPMENT PADS SHALL BE COORDINATED WITH THE SELECTED
EQUIPMENT MANUFACTURER AND/OR SUPPLIER. LOCATIONS ARE TO BE
APPROVED BY THE VHA COR PRIOR TO PROCEEDING WITH THE WORK.
Q. AT TELECOMMUNICATION ROOMS: PROVIDE 3/4" X 8'-0" HIGH FIRE-
RETARDANT-TREATED PLYWOOD SHEATHING OVER TYPE X GYPSUM BOARD.
BOTTOM TO BE LOCATED AT 4" AFF VERIFY LENGTHS AND LOCATIONS WITH
ELECTRICAL DRAWINGS. REFER TO SPECIFICATION SECTION 06 10 00.
R. PROVIDE INDEPENDENT FRAMING AND ATTACHMENTS TO THE STRUCTURE,
ADEQUATE TO SUPPORT THE CEILING SYSTEM, LIGHT FIXTURES, DUCTS,
DIFFUSERS, SPRINKLER PIPING AND BUS DUCTS.
S. CONTRACTOR TO INSTALL WOOD BLOCKING AND PLYWOOD AS REQUIRED
FOR THE MOUNTING OF TOILET ACCESSORIES, MILLWORK, CASEWORK, AV
EQUIPMENT, MEP ITEMS AND RADIOLOGY EQUIPMENT, ETC. REFER TO
SPECIFICATIONS.
T. PROPRIETARY PRODUCTS SHOWN ON THE DRAWINGS SHALL MEET
SPECIFICATION REQUIREMENTS.
U. REFER TO SPECIFICATION SECTION 01 45 29 FOR REQUIRED TESTING AND
INSPECTIONS.
THIS PROJECT IS TO BE DONE IN CONJUNCTION WITH PROJECT #504-10-709 -
"RENOVATE BUILDING 4 - 1ST FLOOR" AS COORDINATED BY THE COR. THE
RENOVATION OF SPACES IN BUILDING 12 AND BUILDING 44 OUTLINED WITHIN
THIS PROJECT SHALL OCCUR PRIOR TO 504-10-709 - "RENOVATE BUILDING 4 -
1ST FLOOR" WITH THE EXCEPTION OF THE GI900 SHEETS. REFER TO THE GI900
SHEETS FOR WORK TO BE DONE AFTER THE COMPLETION OF 504-10-709 -
"RENOVATE BUILDING 4 - 1ST FLOOR".
PHASING
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
GENERAL NOTES
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI002
GENERAL ABBREVIATIONS, NOTES,
& SYMBOLS
RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
12 & 44
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
A
ABA ARCHITECTURAL BARRIERS ACT
AC AIR CONDITIONING
AD AREA DRAIN
ADJ ADJUSTABLE / ADJACENT
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZED
AP ACCESS PANEL
APPROX APPROXIMATE
ARCH ARCHITECT / ARCHITECTURAL
ATTEN ATTENUATION
AUTO AUTOMATIC
AV AUDIO / VISUAL
AVG AVERAGE
B
BD BOARD
BLDG BUILDING
BM BENCH MARK / BEAM
BO BOTTOM OF
BOC BACK OF CURB
BOT BOTTOM
BRG BEARING
BRK BRICK
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BVL BEVELED
C
CAP CAPACITY
CB CATCH BASIN
CCTV CLOSED CIRCUIT TV
CF CUBIC FEET
CFGS (ACCESSIBLE) CLEAR FLOOR OR
GROUND SPACE
CFM CUBIC FEET PER MINUTE
CI CAST IRON
CIP CAST-IN-PLACE
CL CENTER LINE
CLG CEILING
CLR CLEAR / CLEARANCE
CMP CORRUGATED METAL PIPE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
COL COLUMN
COMB COMBINATION
CONC CONCRETE
CONN CONNECTION / CONNECT
CONST CONSTRUCT / CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
COORD COORDINATE
COR CONTRACTING OFFICER'S
REPRESENTATIVE
CORR CORRIDOR / CORRUGATED
CP CONCRETE PIPE
CS COUNTERSINK
CU CUBIC
CW COLD WATER
D
DBL DOUBLE
DEMO DEMOLISH / DEMOLITION
DEPT DEPARTMENT
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
E
E EAST
EA EACH
EF EXHAUST FAN
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EM EMERGENCY
EP ELECTRICAL PANELBOARD
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
ETR EXISTING TO REMAIN
EW EACH WAY
EWC ELECTRIC WATER COOLER
EXH EXHAUST
EXIST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FB FACE BRICK
FBO FURNISHED BY OWNER
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FDN FOUNDATION
FF FINISH FLOOR
FF&E FIXTURES, FURNITURE & EQUIPMENT
FFE FINISH FLOOR ELEVATION
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIXT FIXTURE
FLR FLOOR
FLUOR FLUORESCENT
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RATED
FRMG FRAMING
FS FLOOR SINK
FT FOOT/ FEET
FTG FOOTING
FUT FUTURE
G
GA GAUGE
GALV GALVANIZED
GC GENERAL CONTRACTOR
GOVT GOVERNMENT
GPM GALLON PER MINUTE
H
H HIGH
HB HOSE BIBB
HC HOLLOW CORE
HORIZ HORIZONTAL
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING / VENTILATING / AIR
CONDITIONING
HW HOT WATER
HYD HYDRANT
I
IBC INTERNATIONAL BUILDING CODE
ID INSIDE DIAMETER
IN INCH
INCL INCLUDE (D), (ING)
INFO INFORMATION
INST INSTALL / INSTALLATION
INSUL INSULATE / INSULATION
INT INTERIOR
INV INVERT
J
JAN JANITOR
JB JUNCTION BOX
JST JOIST
JT JOINT
K
KIT KITCHEN
KO KNOCKOUT
L
L LONG / LENGTH
LAB LABORATORY
LAV LAVATORY
LBS POUNDS
LF LINEAR FOOT (FEET)
LH LEFT HAND
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LPT LOW POINT
LRG LARGE
LT LIGHT
LTG LIGHTING
LVR LOUVER
LWC LIGHTWEIGHT CONCRETE
M
MAS MASONRY
MAX MAXIMUM
MBR MEMBER
MECH MECHANICAL
MED MEDIUM
MFG MANUFACTURING
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MOD MODULAR
MTD MOUNTED
MTG MOUNTING
MTL METAL
N
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NSF NET SQUARE FEET
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD / OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
OZ OUNCE
P
PA PUBLIC ADDRESS
PB PUSH BUTTON
PC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PERF PERFORATE (D)
PERM PERMANENT
PERP PERPENDICULAR
PL PLATE / PROPERTY LINE
PLUMB PLUMBING
PNL PANEL
PR PAIR
PREFAB PREFABRICATE (D)
PREFIN PREFINISHED
PRELIM PRELIMINARY
PREP PREPARE (D)
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
PVG PAVING
Q
QTY QUANTITY
R
R RISER / RADIUS
RA RETURN AIR
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RE REFER TO / REFERENCE
REINF REINFORCE (D), (ING)
REQD REQUIRED
REV REVISED/ REVISION
RH RIGHT HAND
RM ROOM
ROW RIGHT OF WAY
RR RESTROOM
RTU ROOF TOP UNIT
S
S SOUTH
SAN SANITARY SEWER
SCH SCHEDULE
SCRN SCREEN
SECT SECTION
SF SQUARE FOOT (SQFT)
SHT SHEET
SIM SIMILAR
SOG SLAB ON GRADE
SPEC SPECIFICATION (S)
SPKLR SPRINKLE
SPKR SPEAKER
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STL STEEL
STOR STORAGE
STRUCT STRUCTURE / STRUCTURAL
SUSP SUSPENDED
SY SQUARE YARD (SQ YD)
SYM SYMMETRICAL / SYMBOL
SYS SYSTEM
T
TCKC (ACCESSIBLE) TOE CLEARANCE AND
KNEE CLEARANCE
TEL TELEPHONE
TEMP TEMPORARY / TEMPERED
THK THICK (NESS)
THRU THROUGH
TO TOP OF
TOC TOP OF CURB / CONCRETE
TOD TOP OF DECK
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOR TOP OF ROOF
TOS TOP OF STEEL
TOW TOP OF WALL
TRANSF TRANSFORMER
TV TELEVISION
TYP TYPICAL
U
UH UNIT HEATER
UNO UNLESS NOTED OTHERWISE
V
VERT VERTICAL
VEST VESTIBULE
VHA VETERANS HEALTH ADMINISTRATION
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
W
W WEST, WIDTH, WIDE
W/ WITH
W/IN WITHIN
W/O WITHOUT
WC WATER CLOSET
WH WALL HYDRANT / WATER HEATER
WT WEIGHT
X, Y, Z, MISC
& AND
@ AT
YD YARD
A. ALL DIMENSIONS ARE MEASURED FROM THE FINISH FLOOR AND THE FINISH WALL, UNLESS NOTED OTHERWISE. ACCESSIBILITY GUIDELINES ARE BASED ON “PG-18-13 VA BARRIER FREE DESIGN
STANDARD” AND THE “ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS).”
B. ACCESSIBLE UNOBSTRUCTED REACH RANGES:
1. FORWARD REACH = 15" MIN TO 48" MAX
2. SIDE REACH = 15" MIN TO 48" MAX
C. DOOR HARDWARE (TO CENTER OF HARDWARE):
STANDARD MOUNTING HEIGHTS:
1. PUSH PLATES = 42"
2. PULL HANDLES = 42"
3. KNOBS / LEVERS = 40"
4. PANIC DEVICE = 42" CL OF BAR
5. KICKPLATES:
a. WIDTH = DOOR WIDTH MINUS 2"
b. CENTER HEIGHT = 16" FROM BO DOOR
6. THRESHOLDS:
a. STANDARD = 1/2" MAX
b. EXTERIOR SLIDING DOORS = 3/4" MAX
D. DRINKING FOUNTAINS & ELECTRICAL WATER COOLERS (TO SPOUT):
1. STANDARD = 38" MIN TO 43" MAX
2. ACCESSIBLE = 36" MAX (27" MIN CLEAR KNEE SPACE)
E. COUNTERTOPS (TO SINK RIM / COUNTERTOP):
1. ACCESSIBLE = 28" MIN TO 34" MAX
F. WATER CLOSETS (TO TOP OF SEAT):
1. STANDARD = 14" TO 15"
2. ACCESSIBLE (TO TOP OF SEAT) = 17" TO 19"
3. ACCESSIBLE FLUSH CONTROLS = 44" MAX
G. URINALS (TO RIM):
1. STANDARD = 24" MAX
2. ACCESSIBLE = 17" MAX
3. ACCESSIBLE FLUSH CONTROLS = 44" MAX
H. LAVATORIES (TO SINK RIM / COUNTERTOP):
1. STANDARD = 36" MAX
2. ACCESSIBLE = 34" MAX (29" MIN CLEAR KNEE SPACE)
I. MIRRORS:
1. TO B/O REFLECTIVE SURFACE:
a. STANDARD = VARIES
b. ACCESSIBLE = 40" MAX
2. TO T/O REFLECTIVE SURFACE:
a. STANDARD = VARIES
b. ACCESSIBLE = 74" MIN
J. GRAB BARS - ACCESSIBLE (TO TOP OF BAR):
1. WATER CLOSETS = 33" MIN TO 36" MAX
2. SHOWERS = 33" MIN TO 36" MAX (FROM BO SHOWER)
3. BATHTUBS:
a. TOP BAR = 33" MIN TO 36" MAX
b. BOTTOM BAR = 9" ABOVE TOP OF TUB
K. TOILET PARTITIONS:
1. TO BOTTOM = 12"
2. TO TOP = 70"
L. URINAL PARTITIONS:
1. TO BOTTOM = 18"
2. TO TOP = 60"
M. TOILET PAPER DISPENSER (TO CL OF OUTLET):
1. STANDARD = 24"
2. ACCESSIBLE = 15" MIN TO 48" MAX
N. WALL MOUNTED SOAP DISPENSER (TO CL OF PUSH BUTTON):
1. STANDARD = 40"
2. ACCESSIBLE = VARIES (REFER TO OBSTRUCTED AND UNOBSTRUCTED REACH RANGES)
3. ACCESSIBLE SIDE REACH = 46" MAX ABOVE SINK IN COUNTER
O. PAPER TOWEL DISPENSER / WASTE RECEPTACLE (TO TOWEL SLOT):
1. STANDARD = 40" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN
3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN
P. WARM AIR HAND DRYER (TO PUSH SWITCH):
1. STANDARD = 44" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN
3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN
Q. SANITARY NAPKIN DISPENSER (TO CL OF COIN SLOT):
1. STANDARD = 40" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN
3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN
R. SANITARY NAPKIN DISPOSAL (TO TOP OF UNIT):
1. STANDARD = 28" MAX
2. ACCESSIBLE = 19" MIN TO 24" MAX (TO OPENING).
S. TOILET SEAT COVER DISPENSERS (TO OPENING):
1. STANDARD = 40" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX & 15" MIN
3. ACCESSIBLE SIDE REACH = 48" MAX & 15" MIN
T. SHELVES: ACCESSIBLE = 48" MAX
U. COAT HOOKS:
1. STANDARD = 68"
2. ACCESSIBLE = 48" MAX
V. CHALKBOARDS, TACKBOARDS & MARKERBOARDS:
1. STANDARD = 32" TO 39" (TO BO BOARD OR CHALK TRAY)
2. STANDARD = 80" (RECOMMENDED, TO TOP OF BOARD)
W. THERMOSTATS & CONTROL DEVICES (TO TOP):
1. ACCESSIBLE FORWARD REACH = 48" MAX
2. ACCESSIBLE SIDE REACH = 48" MAX
X. LIGHT SWITCHES & CARD READERS (TO CL):
1. LOCATE 6" FROM DOOR JAMB
2. ACCESSIBLE = 48" MAX
Y. CONVENIENCE RECEPTACLES / ELECTRICAL / TELEPHONE / DATA (TO CL):
1. STANDARD = 18"
2. ACCESSIBLE = 15" MIN
Z. EXIT LIGHTS - WALL MOUNTED:
1. 2" BELOW CEILING
2. 2" MIN ABOVE DOOR FRAME EQUAL SPACE FROM CEILING TO TOP OF FRAME
AA. FIRE EXTINGUISHERS (TO TOP UNLESS NOTED OTHERWISE):
1. GROSS WT 40 LBS OR LESS = 60" MAX
2. GROSS WT MORE THAN 40 LBS = 42" MAX
3. ACCESSIBLE = 40" MAX (TO BO CABINET)
BB. FIRE ALARM PULL STATION (TO LEVER):
1. STANDARD = 48" MAX
2. ACCESSIBLE FORWARD REACH = 48" MAX
3. ACCESSIBLE SIDE REACH = 48" MAX
CC. SMOKE AND / OR HEAT DETECTORS:
1. STANDARD = CEILING HEIGHT
DD. HORN / SPEAKER / VISUAL SIGNALS:
1. STANDARD = 80" AFF OR 6" BELOW CEILING - WHICHEVER IS LOWER
EE. ROOM SIGNAGE (TO CL):
1. STANDARD = 60" HIGH AFF & WITHIN 18" OF LATCH SIDE OF DOOR
GENERAL NOTES
2'
M
IN
SECTION
TOE CLEARANCE (TC) & KNEE CLEARANCE
(KC)
6" MAX 11" MAX
1' - 5" MAX
8"
9" M
A X
KC
TC
CLEAR
FLOOR
SPACE
NOTE: PARTITION DOOR IS
TO BE LOCATED OPPOSITE
OF WC LOCATION
5' - 6" CLEAR
6'
C
LE
A R
ACCESSIBLE WATER CLOSET
APPROACH
A P
P R
O A
C H
LAVATORIES
5' - 7" MIN
GRAB BAR
FLUSH HANDLES ON THE
TRANSFER SIDE
24" MIN
18" MAX
16" MIN
DISPENSER
T O
T O
P O
F B
A R
M
IN
T O
6"
M A
X
12" MIN
T O
P O
F S
E A
T
M
IN
T
O
7" M
A X
ACCESSIBLE WATER CLOSET
BACK WALL
GRAB BAR
T O
P O
F O
P E
N
IN
G
M A
X
DISPENSER
M
IN
1/
2" B
O O
P E
N
IN
G
M
IN
54" MIN
T O
T O
P O
F B
A R
M
IN
T O
6"
M A
X
MAX
12" 42" MIN
7" TO 9"
ACCESSIBLE WATER CLOSET
SIDE WALL
SANITARY
NAPKIN
DISPOSAL
TOILET PAPER
DISPENSER
1'
M
IN
SOAP DISPENSERMIRROR SANITARY
NAPKIN
DISPENSER
INTEGRAL WASTE
DISPOSAL WHERE
APPLICABLE
TOWEL
DISPENSER
PAPER TOWEL
DISPENSER W/
INTEGRAL WASTE
DISPOSAL
BABY CHANGING
STATION
PASS-THRUPAPER TOWEL
DISPENSER
R E
F
LE
C T
IV
E
S U
R F
A C
E
3'
M A
X T
O B
O
4'
M A
X
R E
F
LE
C T
IV
E
S U
R F
A C
E
6'
M
IN
T O
T O
P O
F
M
IN
TOILET ACCESSORIES
MOUNTING HEIGHTS
LIGHT SWITCH
M A
X
4'
MAX
1' - 0"
2"
THERMOSTAT
M
IN
1'
RECEPTACLE
SWITCH AND RECEPTACLE
MOUNTING HEIGHTS
FIRE EXTINGUISHER
& STANDARD BRACKET
M F
P A
IN
S
T A
LL
P
E R
FIRE EXTINGUISHER
MOUNTING HEIGHT
CLEAR FLOOR OR GROUND SPACES (CFGS)
M
IN
30" MIN
M
IN
36" MIN
M
IN
30" MIN
CFGS
(30x48)
CFGS
(36x48)
CFGS
(30x60)
CFGS
(30X48)
M A
X
PLAN
SECTION
25" MAX
17" MIN
TCKC
ACCESSIBLE LAVATORY (WALL MOUNTED)
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI003
ACCESSIBILITY STANDARDS RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
12 & 44
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05Number: Revision: Date:
12-001A
STORAGE
12-001
WAREHOUSE
12-002
SAFE
12-003
RECEIVING
12-004
MAILROOM
12-005
TOILET
12-004A
CORRIDOR
E D
E X
FE
ED
E X
FE
EA
E
AE
A
0HSP
0HSP
0HSP
0H S
P
0H S
P
0H S
P
0HSP
0H S
P
CPOET
46' - 0"
LIFE SAFETY LEGEND
EXIT ACCESS (EA)
EXIT (EX)
EXIT SIGNS (ES)
HAZARDOUS AREA
PROTECTION (HAZ)
FIRE EXTINGUISHER (FE) / FIRE
EXTIGUISHER CABINET (FEC)
EXTERIOR EXIT
STAIRWAY / RAMP
EXIT ACCESS
STAIRWAY
EA EA
EXEX
EDED EXIT DISCHARGE (EX)
FE FEC
1-HR FIRE EXISTING
2-HR FIRE EXISTING
1-HR SMOKE BARRIER
0-HR SMOKE
1-HR SMOKE BARRIER EXISTING
0HSP
1HSB
1HSB
1HFB
2HFB
COMMON PATH OF EGRESS TRAVEL (CPOET)
START POINT
NOT IN CONTRACT
THIS PROJECT WILL PROVIDE ALL NECESSARY PLANNING AND SERVICES TO
RENOVATE EXISTING WAREHOUSE SPACE OF BUILDING 12 TO BE A MAILROOM
TO BE USED DURING BUILDING 4 CONSTRUCTION. THIS WORK INCLUDES THE
RENOVATION OF 750 SF EXISTING STORAGE SPACE AND ADDITION OF UTILITY
SERVICES SUCH AS PLUMBING, MECHANICAL, ELECTRICAL, AND IT.
CODE COMPLIANCE SUMMARY
BUILDING INFORMATION
APPLICABLE CODES
MEANS OF EGRESS
EXISTING STORAGE OCCUPANCIES
TRAVEL DISTANCE (TD) - MAXIMUM: 400 FEET
COMMON PATH OF EGRESS TRAVEL (CPOET) - MAXIMUM: 100 FEET
DEAD-END CORRIDORS - MAXIMUM: 100 FEET
NUMBER OF EXITS - MINIMUM: 1 EXIT REQUIRED
MINIMUM DOOR LEAF WIDTH: 32 INCHES
EXISTING BUILDING#: 12
MAIN OCCUPANCY CLASSIFICATION: EXISTING S-2 (STORAGE)
FULLY FIRE SPRINKLERED: YES
OCCUPANT LOAD SUMMARY
• VA DESIGN GUIDELINES
• VA PHYSICAL SECURITY DESIGN MANUAL
• NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 LIFE SAFETY CODE - 2021
• INTERNATIONAL BUILDING CODES (IBC) - 2021
• PG-18-13 VA SUSTAINABLE DESIGN MANUAL (01.01.17, REVISED 11.01.18)
• NFPA 1 FIRE CODE - 2021
• NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS - 2019
• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE - 2019
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) 2015
• VA FIRE PROTECTION DESIGN MANUAL, 7TH EDITION
• INTERNATIONAL PLUMBING CODE (IPC) - 2021
BUSINESS 722 150 GROSS 5
OCCUPANCY
CATEGORY
SQ. FT. LOAD FACTOR OCCUPANT LOAD HATCH
THE FOLLOWING IS THE OCCUPANCY OF SPACE PRIOR TO RENOVATION:
OCCUPANCY CATEGORY: STORAGE
SQ FT: 722
LOAD FACTOR: 300 GROSS
TOTAL OCCUPANY: 3
CHANGE IN OCCUPANT LOAD: + 2
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
P la n N or th
True North
11 19
141312
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI111
LIFE SAFETY PLAN - BUILDING 12 -
LEVEL 1
RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
3/16" = 1'-0"
LIFE SAFETY PLAN - BUILDING 12 - LEVEL 1
F2
584 SF
44-1613
DRUG CACHE
44-1612A
EMS CHIEF
44-1612
EMS OPEN OFFICE
44-1612B
EMS OFFICE
44-1612C
FUTURE TR ROOM
44-1611
SYSTEMS
44-1609
HAC
44-1608
GROUP THERAPY
44-C0-5
CORRIDOR
44-C0-8
CORRIDOR
44-1615
STAFF LOUNGE
C0-10
VESTIBULE
44-1610
GROUP THERAPY
44-1649
MENS RR
44-C0-15
CORRIDOR
44-1614
SAFE
44-1616
EXAM
44-1619
OFFICE
44-1617
OFFICE
44-1646
TR
44-1644
ELECTRICAL
44-1642
COMM CENTER
44-C0-3
WAITING
44-C0-2
ENTRY
44-C0-1
VESTIBULE
44-E0-1
ELEVATOR
44-1607
ELEV RM
44-1605
MECHANICAL
44-S0-1
STAIR #1
44-S0-2
STAIR #2
44-1647
WOMENS RR
44-1645
WOMENS RR
44-1643
MENS RR
44-1621
OFFICE PSYCH
44-1623
OFFICE PSYCH
44-C0-12
CORRIDOR
44-C0-9
CORRIDOR
44-1618
OFFICE STUDENT
44-1620
PATIENT TESTING
44-1628
OFFICE STUDENT
44-1638
SOCIAL WORK
44-C0-14
COPY/ FAX
44-C0-13
CORRIDOR
44-1641
OFFICE
44-1639
OFFICE
44-1637
SOCIAL WORK
44-1635
SOCIAL WORK
44-1633
OFFICE PSYCH (F)
44-1631
OFFICE PSYCH
44-1629
OFFICE PSYCH
44-1627
OFFICE PSYCH
44-1625
OFFICE PROGRAM
MGR
44-1601
OXYGEN (F)
44-1603
OXYGEN(E)
44-1640
STORAGE
ED
E X
E D
E X
FEC
FEC
FEC
ED
E A
EA
E A
E A
1H S
B
1HSB
0HSP
1HFB
1H F
B
1HFB
CPOET
53' - 0"
CPOET
40' - 0"
EA
LIFE SAFETY LEGEND
EXIT ACCESS (EA)
EXIT (EX)
EXIT SIGNS (ES)
HAZARDOUS AREA
PROTECTION (HAZ)
FIRE EXTINGUISHER (FE) / FIRE
EXTIGUISHER CABINET (FEC)
EXTERIOR EXIT
STAIRWAY / RAMP
EXIT ACCESS
STAIRWAY
EA EA
EXEX
EDED EXIT DISCHARGE (EX)
FE FEC
1-HR FIRE EXISTING
2-HR FIRE EXISTING
1-HR SMOKE BARRIER
0-HR SMOKE
1-HR SMOKE BARRIER EXISTING
0HSP
1HSB
1HSB
1HFB
2HFB
COMMON PATH OF EGRESS TRAVEL (CPOET)
START POINT
NOT IN CONTRACT
CODE COMPLIANCE SUMMARY
BUILDING INFORMATION
APPLICABLE CODES
MEANS OF EGRESS
EXISTING BUSINESS OCCUPANCIES
TRAVEL DISTANCE (TD) - MAXIMUM: 300 FEET
COMMON PATH OF EGRESS TRAVEL (CPOET) - MAXIMUM: 100 FEET
DEAD-END CORRIDORS - MAXIMUM: 50 FEET
NUMBER OF EXITS - MINIMUM: 1 EXIT REQUIRED
MINIMUM DOOR LEAF WIDTH: 32 INCHES
EXISTING BUILDING#: 44
MAIN OCCUPANCY CLASSIFICATION: EXISTING B (BUSINESS)
FULLY FIRE SPRINKLERED: YES
• VA DESIGN GUIDELINES
• VA PHYSICAL SECURITY DESIGN MANUAL
• NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 LIFE SAFETY CODE - 2021
• INTERNATIONAL BUILDING CODES (IBC) - 2021
• PG-18-13 VA SUSTAINABLE DESIGN MANUAL (01.01.17, REVISED 11.01.18)
• NFPA 1 FIRE CODE - 2021
• NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS - 2019
• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE - 2019
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) 2015
• VA FIRE PROTECTION DESIGN MANUAL, 7TH EDITION
• INTERNATIONAL PLUMBING CODE (IPC) - 2021
OCCUPANT LOAD SUMMARY
THIS PROJECT WILL PROVIDE ALL NECESSARY PLANNING AND SERVICES TO
RENOVATE EXISTING STORAGE SPACE ON THE FIRST FLOOR OF BUILDING 44
INTO OFFICES AND SECURE STORAGE. THIS WORK INCLUDES THE RENOVATION
OF 1270 SF OF EXISTING ANCILLARY STORAGE SPACE AND ADDITION OF UTILITY
SERVICES SUCH AS PLUMBING, MECHANICAL, ELECTRICAL, AND IT.
OCCUPANCY
CATEGORY
SQ. FT. LOAD FACTOR OCCUPANT LOADHATCH
BUSINESS 680 150 GROSS 5
THE FOLLOWING IS THE OCCUPANCY OF SPACE PRIOR TO RENOVATION:
OCCUPANCY CATEGORY: STORAGE
SQ FT: 1270
LOAD FACTOR: 300 GROSS
TOTAL OCCUPANY: 5
STORAGE 590 300 GROSS 2
CHANGE IN OCCUPANT LOAD: + 2
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
SHEET KEYNOTES
P la n N or th
Tru e
Nor th
4 35
SW
9TH AVE
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI112
LIFE SAFETY PLAN - BUILDING 44 -
LEVEL 1
RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
3/16" = 1'-0"
LIFE SAFETY PLAN - BUILDING 44 - LEVEL 1
F3
1. EXISTING EXIT CORRIDOR
DN
44-2613
CLEAN LINEN
STORAGE
44-2615
MEN RR
44-2617
OFFICE EMP SP
44-S1-2
STAIR #2
44-2619
VOC REHAB
44-2621
VOC REHAB
44-C1-10
CORRIDOR
44-2620
CHAPLAIN
44-2618
PATIENT COMP
44-2628
TR
44-2648
ELECTRICAL
44-2646
OFFICE
44-2630
COMM CENTER
44-C1-3
WAITING
44-C1-2
ENTRY
44-C1-9
CORRIDOR
44-C1-8
CORRIDOR
44-2647
GROUP THERAPY
44-2645
GROUP THERAPY
44-2606
OFFICE
44-2608
REC THER
44-2604
REC THER
44-E1-1
ELEVATOR
44-C1-1
VESTIBULE
44-2605
REC STORAGE
44-2601
HAC
44-C1-4
CORRIDOR
44-2603
DINING
44-2603B
PING PONG
44-2607
REC STORAGE
44-2609
KITCHEN
44-2611
WOMENS RR
44-C1-6
CORRIDOR
44-2615B
TOILET
44-2615A
TOILET
44-S1-1
STAIR #1
44-2623
ADD THER
44-2625
SOCIAL WORK
44-2627
PROGRAM MGR
44-2629
SOCIAL WORK
44-2631
NURSE PRAC
44-2633
OFFICE ADMIN
44-2635
OFFICE SHARED
44-2637
OFFICE SUI PREV
44-2639
OFFICE REC COORD
44-C1-12
CORRIDOR
44-C1-11
CORRIDOR
44-2624
OFFICE STUDENT
44-2622
ADD THER
44-2632
MENS RR
44-2634
WOMENS RR
44-2642
STORAGE
44-C1-14
COPY/ FAX
44-C1-13
CORRIDOR
44-2641
OFFICE CH PSYCH
44-2643
CONF/ LIBRARY
44-2641A
OFFICE CH PSYCH
ED
E X
EDEX
FEC
FEC
FEC
E A
EA
EA
0HSP
0HSP
0H S
P 0H
S P
CPOET
41' - 0"
E A
CODE COMPLIANCE SUMMARY
BUILDING INFORMATION
APPLICABLE CODES
MEANS OF EGRESS
EXISTING BUSINESS OCCUPANCIES
TRAVEL DISTANCE (TD) - MAXIMUM: 300 FEET
COMMON PATH OF EGRESS TRAVEL (CPOET) - MAXIMUM: 100 FEET
DEAD-END CORRIDORS - MAXIMUM: 50 FEET
NUMBER OF EXITS - MINIMUM: 1 EXIT REQUIRED
MINIMUM DOOR LEAF WIDTH: 32 INCHES
EXISTING BUILDING#: 44
MAIN OCCUPANCY CLASSIFICATION: EXISTING B (BUSINESS)
FULLY FIRE SPRINKLERED: YES
• VA DESIGN GUIDELINES
• VA PHYSICAL SECURITY DESIGN MANUAL
• NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 101 LIFE SAFETY CODE - 2021
• INTERNATIONAL BUILDING CODES (IBC) - 2021
• PG-18-13 VA SUSTAINABLE DESIGN MANUAL (01.01.17, REVISED 11.01.18)
• NFPA 1 FIRE CODE - 2021
• NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS - 2019
• NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE - 2019
• ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS) 2015
• VA FIRE PROTECTION DESIGN MANUAL, 7TH EDITION
• INTERNATIONAL PLUMBING CODE (IPC) - 2021
OCCUPANT LOAD SUMMARY
OCCUPANCY
CATEGORY
SQ. FT. LOAD FACTOR OCCUPANT LOADHATCH
STORAGE 680 300 GROSS 3
THIS PROJECT WILL PROVIDE ALL NECESSARY PLANNING AND SERVICES TO
REPURPOSE EXISTING CLASSROOM ON THE SECOND FLOOR OF BUILDING 44
INTO STORAGE. THIS WORK INCLUDES THE ADDITION OF UTILITY SERVICES
SUCH AS PLUMBING, MECHANICAL, ELECTRICAL, AND IT.
THE FOLLOWING IS THE OCCUPANCY OF SPACE PRIOR TO RENOVATION:
OCCUPANCY CATEGORY: ASSEMBLY
SQ FT: 693
LOAD FACTOR: 15 GROSS
TOTAL OCCUPANY: 46
CHANGE IN OCCUPANT LOAD: - 43
LIFE SAFETY LEGEND
EXIT ACCESS (EA)
EXIT (EX)
EXIT SIGNS (ES)
HAZARDOUS AREA
PROTECTION (HAZ)
FIRE EXTINGUISHER (FE) / FIRE
EXTIGUISHER CABINET (FEC)
EXTERIOR EXIT
STAIRWAY / RAMP
EXIT ACCESS
STAIRWAY
EA EA
EXEX
EDED EXIT DISCHARGE (EX)
FE FEC
1-HR FIRE EXISTING
2-HR FIRE EXISTING
1-HR SMOKE BARRIER
0-HR SMOKE
1-HR SMOKE BARRIER EXISTING
0HSP
1HSB
1HSB
1HFB
2HFB
COMMON PATH OF EGRESS TRAVEL (CPOET)
START POINT
NOT IN CONTRACT
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
SHEET KEYNOTES
P la n N or th
Tru e
Nor th
4 35
SW
9TH AVE
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI113
LIFE SAFETY PLAN - BUILDING 44 -
LEVEL 2
RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
3/16" = 1'-0"
LIFE SAFETY PLAN - BUILDING 44 - LEVEL 2
F3
1. EXISTING EXIT CORRIDOR
UP
UP
DN
DN
12-001A
STORAGE
12-001
WAREHOUSE
12-002
SAFE
12-003
RECEIVING
12-004
MAILROOM
12-005
TOILET
12-004A
CORRIDOR
DEPARTMENT LEGEND
LOGISTICS
ENVIRONMENTAL MANAGMENT SERVICES
GENERAL
NOT IN CONTRACT
A. ELECTRICAL AND MECHANICAL WORK MAY EXTEND TO NIC AREAS.
44-1613
DRUG CACHE
44-1612A
EMS CHIEF
44-1612
EMS OPEN OFFICE
44-1612B
EMS OFFICE
44-1612C
FUTURE TR ROOM
44-1611
SYSTEMS
44-1609
HAC
44-1608
GROUP THERAPY
44-C0-5
CORRIDOR
44-C0-8
CORRIDOR
44-1615
STAFF LOUNGE
C0-10
VESTIBULE
44-1610
GROUP THERAPY
44-1649
MENS RR
44-C0-15
CORRIDOR
44-1614
SAFE
44-1616
EXAM
44-1619
OFFICE
44-1617
OFFICE
44-1646
TR
44-1644
ELECTRICAL
44-1642
COMM CENTER
44-C0-3
WAITING
44-C0-2
ENTRY
44-C0-1
VESTIBULE
44-E0-1
ELEVATOR
44-1607
ELEV RM
44-1605
MECHANICAL
44-S0-1
STAIR #1
44-S0-2
STAIR #2
44-1647
WOMENS RR
44-1645
WOMENS RR
44-1643
MENS RR
44-C0-9
CORRIDOR
44-C0-4
CORRIDOR
44-2613
CLEAN LINEN
STORAGE
44-2615
MEN RR
44-2617
OFFICE EMP SP
44-S1-2
STAIR #2
44-2619
VOC REHAB
44-2621
VOC REHAB
44-C1-10
CORRIDOR
44-2620
CHAPLAIN
44-2618
PATIENT COMP
44-2628
TR
44-2648
ELECTRICAL
44-2646
OFFICE
44-2630
COMM CENTER
44-C1-3
WAITING
44-C1-2
ENTRY
44-C1-9
CORRIDOR
44-C1-8
CORRIDOR
44-2647
GROUP THERAPY
44-2645
GROUP THERAPY
44-2606
OFFICE
44-2608
REC THER
44-2604
REC THER
44-E1-1
ELEVATOR
44-C1-1
VESTIBULE
44-2605
REC STORAGE
44-2601
HAC
44-C1-4
CORRIDOR
44-2603
DINING
44-2603B
PING PONG
44-2607
REC STORAGE
44-2609
KITCHEN
44-2611
WOMENS RR
44-C1-6
CORRIDOR
44-2615B
TOILET
44-2615A
TOILET
44-S1-1
STAIR #1
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
N or th
SW 6TH AVE
10 8
US H
IG
HW
AY 6
(A
M
ARIL
LO
B
LV
D)
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI121
DEPARTMENTAL PLANS RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
12 & 44
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
P la n N or th
True North1/8" = 1'-0"
DEPARTMENTAL PLAN - BUILDING 12 - LEVEL 1
C5
P la n N or th
Tru e
Nor th
1/8" = 1'-0"
DEPARTMENTAL PLAN - BUILDING 44 - LEVEL 1
F6
DEPARTMENTAL AREA SCHEDULE
NUMBER ROOM NAME
EXISTING
AREA
PG-18-9
AREA
DESIGNED
AREA
BLDG 12 - LEVEL 1
LOGISTICS
12-003 RECEIVING 62 SF 120 SF 109 SF
12-004 MAILROOM 467 SF 474 SF 504 SF
529 SF 594 SF 613 SF
ENVIRONMENTAL MANAGMENT SERVICES
12-001A STORAGE 361 SF 359 SF
361 SF 0 SF 359 SF
GENERAL
12-005 TOILET 34 SF 60 SF 67 SF
12-004A CORRIDOR 0 SF 0 SF 31 SF
34 SF 60 SF 98 SF
924 SF 654 SF 1070 SF
BLDG 44 - LEVEL 1
ENVIRONMENTAL MANAGMENT SERVICES
44-1612 EMS OPEN OFFICE 323 SF 281 SF 334 SF
44-1612A EMS CHIEF 206 SF 100 SF 104 SF
44-1612B EMS OFFICE 146 SF 100 SF 90 SF
675 SF 481 SF 529 SF
PHARMACY
44-1613 DRUG CACHE 738 SF 600 SF 584 SF
738 SF 600 SF 584 SF
1413 SF 1081 SF 1112 SF
BLDG 44 - LEVEL 2
ENVIRONMENTAL MANAGMENT SERVICES
44-2613 CLEAN LINEN STORAGE 323 SF 240 SF 573 SF
323 SF 240 SF 573 SF
323 SF 240 SF 573 SF
P la n N or th
Tru e
Nor th
1/8" = 1'-0"
DEPARTMENTAL PLAN - BUILDING 44 - LEVEL 2
F2
12-001A
STORAGE
12-001
WAREHOUSE
12-002
SAFE
12-003
RECEIVING
12-004
MAILROOM
12-005
TOILET
12-004A
CORRIDOR
4 4
5 6 7
A. THE WORK SHOWN ON THIS SHEET IS TO BE DONE AFTER THE COMPLETION
OF PROJECT 504-10-709 - "RENOVATE BUILDING 4 - 1ST FLOOR" AND THE VHA
HAS VACATED THE SPACE. COORDINATE WITH VHA COR.
B. REFER TO GI002 AND A-001 FOR ADDITIONAL GENERAL NOTES, SYMBOLS,
AND ABBREVIATIONS.
C. ALL MECHANICAL AND PLUMBING SYSTEMS TO REMAIN IN PLACE AS IS.
AREA OF DEMOLITION
DEMOLITION SYMBOLS LEGEND
DEMOLITION LINE TYPE
EXISTING LINE TYPE
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
P la n N or th
True North
11 19
141312
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI911
POST BLDG 4 CONSTRUCTION
PLAN - BUILDING 12 - LEVEL 1
RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
3/16" = 1'-0"
POST BUILDING 4 CONSTRUCTION PLAN - BUILDING 12 - LEVEL 1
F3
1. DEMOLISH WALL, PATCH AND REPAIR ADJOINING WALLS TO REMAIN
2. REMOVE WALL RECEPTACLES AND ASSOCIATED WIRING TO SOURCE
3. REMOVE AND RETURN DOOR TO VHA
4. REMOVE BOLLARD
5. DEMOLISH RAMP SYSTEM
6. DEMOLISH CANOPY SYSTEM AND POSTS, INCLUDING LIGHTING AND
ASSOCIATED WIRING
7. PATCH AND REPAIR ANY HOLES IN CONCRETE/ASPHALT LEFT AFTER
REMOVAL OF RAMP AND CANOPY
8. REMOVE GUARDRAIL
9. REINSTALL METAL STAIRS
44-2613
CLEAN LINEN
STORAGE
44-2615
MEN RR
44-2617
OFFICE EMP SP
44-S1-2
STAIR #2
44-2619
VOC REHAB
44-2621
VOC REHAB
44-C1-10
CORRIDOR
44-2620
CHAPLAIN
44-2618
PATIENT COMP
44-2628
TR
44-2648
ELECTRICAL
44-2646
OFFICE
44-2630
COMM CENTER
44-C1-3
WAITING
44-C1-2
ENTRY
44-C1-9
CORRIDOR
44-C1-8
CORRIDOR
44-2647
GROUP THERAPY
44-2645
GROUP THERAPY
44-2606
OFFICE
44-2608
REC THER
44-2604
REC THER
44-E1-1
ELEVATOR
44-C1-1
VESTIBULE
44-2605
REC STORAGE
44-2601
HAC
44-C1-4
CORRIDOR
44-2603
DINING
44-2603B
PING PONG
44-2607
REC STORAGE
44-2609
KITCHEN
44-2611
WOMENS RR
44-C1-6
CORRIDOR
44-2615B
TOILET
44-2615A
TOILET
44-S1-1
STAIR #1
A. THE WORK SHOWN ON THIS SHEET IS TO BE DONE AFTER VHA HAS VACATED
THE SPACE. COORDINATE WITH VHA COR.
B. REFER TO GI002 AND A-001 FOR ADDITIONAL GENERAL NOTES, SYMBOLS,
AND ABBREVIATIONS.
C. ALL MECHANICAL, PLUMBING, AND ELECTRICAL SYSTEMS TO REMAIN IN
PLACE AS IS.
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
P la n N or th
Tru e
Nor th
4 35
SW
9TH AVE
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
GI913
POST BLDG 4 CONSTRUCTION
PLAN - BUILDING 44 - LEVEL 2
RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
1/4" = 1'-0"
POST BUILDING 4 CONSTRUCTION PLAN - BUILDING 44 - LEVEL 2
F3
1. PATCH AND REPAIR DAMAGE THROUGHOUT ROOM; VERIFY EXTENTS WITH
VHA COR
AREA OF ASBESTOS ABATEMENT
ABATEMENT PLAN SYMBOLS LEGEND
DEMOLITION LINE TYPE
EXISTING LINE TYPE
A. FULL ASBESTOS ABATEMENT REPORT WILL BE PROVIDED TO SUCCESSFUL
BIDDER.
12-001
WAREHOUSE
12-002
SAFE
12-001A
STORAGE
12-003A
RESTROOM
12-003
OFFICE
1 1 1
7' -6
5'
1"
5'
3/
8'
1/
1/
1"
0'
1"
0'
1"
0'
1"
0'
1"
0'
9" 6"
3"
3"
1' -6
1'
6"
1/
2"
2' 1'
6"
1"
3' 2'
1'
3/ 4"
4'
2' 1'
1/
2"
6' 4'
2'
3/ 8"
8'
4'
3/
8' 4'
2'
1/ 4"
8'
4'
1/ 8"
KEY PLAN
GENERAL NOTES
SHEET KEYNOTES
P la n N or th
True North
11 19
141312
Drawing Title
VA FORM 08 - 6231
F
CONSULTANTS:
750 W HAMPDEN AVE
SUITE 300
ENGLEWOOD, CO 80110
(720) 550-6307
WWW.VALHALLAENGINEERING.COM
10987654321
10987654321
E
D
C
B
A
F
E
D
C
B
A
ARCHITECT/ENGINEERS: STAMP:
Approved: Project Director
Phase Project Title
Location
Issue Date Checked Drawn
Project Number
Drawing Number
Building Number
SEE REVISION
SCHEDULE
R E
V
IS
IO
N
S C
H E
D U
L E
A ut od es k D oc s:
//2 3.
_S w in g- S pa ce
/2 3.
_A
R C
H _R
.r vt
/1 0/
:3
8:
P M
HA111
ASBESTOS ABATEMENT PLAN -
BUILDING 12 - LEVEL 1
RENOVATE FOR SWING SPACE
6010 W AMARILLO BLVD, AMARILLO, TX 79106
504-23-106
GDD AW
100% CONSTRUCTION
DOCUMENTS
VEG 23.05
3/16" = 1'-0"
ASBESTOS ABATEMENT PLAN - BUILDING 12 - LEVEL 1
F3
1. ABATE ASBESTOS CONTAINING GREY EXTERIOR WINDOW CAULKING
1. All work shall conform to the minimum standards of the International Building Code, 2021 edition and any other regulatory agencies that have authority over any portion of the work.
2. Design Loads Dead Loads
Roof superimposed dead load 36 psf Floor superimposed dead load 30 psf Mechanical equipment actual weight
Live Loads Floor
Office 50 psf Partitions 20 psf Roof 20 psf
Roof Snow Load Snow Criteria:
Pf = 20psf, Ce = 1.0, Ct = 1.1, Is = 1.1
Risk Category III
Wind Criteria 114 mph (3 second gust, Ultimate) 88 mph (ASD), Exposure C Building Category = Enclosed Internal Pressure Coefficient = ± 0.18
Seismic Criteria Site Class D, Design Category C, Equivalent Lateral Force Procedure Seismic Force Resisting System = Steel Frame Not Specifically Detailed for Seismic Resistance R = 3, Fa = 1.6, Fv = 2.4, Ss = 0.195, S1 = 0.045, SDS = 0.207, SD1 = 0.072, Ie = 1.25
COMPONENTS AND CLADDING WIND PRESSURES1,2
Zone 1 - Roof Interior
Effective Area
10 sf 20 sf 50 sf 100 sf
1. Special inspection, in accordance with the International Building Code or as required by the construction documents, shall be performed by a qualified inspector from an approved agency. Reports shall be issued to the Architect/Engineer and the Building Department at the completion of each type of work stating whether the work was performed in conformance with the approved plans and specifications. See inspection schedules for specific requirements.
2. Any item that is listed as a discrepancy by the independent testing agency shall be kept in a log by the General Contractor throughout the project. the log shall include the discrepancy number, date of discrepancy, and description of discrepancy. The General Contractor shall contact the engineer in a timely manner to address each discrepancy and keep a record of the required corrections. The letter of substantial completion provided by the engineer cannot be released until every item listed in the discrepancy log has been addressed and resolved.
Zone 2 - Roof Edge
Zone 3 - Roof Corner
Zone 4 - Wall Typical
Zone 5 - Wall Corner
Footnotes:
1. Pressures shown are determined using ASCE 7-16 and are ultimate with ASD level pressures shown in parentheses.
2. Refer to details for wind loading on miscellaneous rooftop structures, etc. Roof overhangs shall be designed for applicable component and cladding loads per Figure 30.9-1 for ASCE 7-16.
3. Refer to Figure 30.3-1 through 30.4-1 in ASCE 7-16 for description of each zone.
Zones3
GENERAL NOTES
Parapet
DESIGN CRITERIA
SHOP DRAWINGS AND SUBMITTALS
1. The Contractor shall coordinate, review and submit shop drawings that identify all penetrations for all trades through structural walls, slabs, beams, and columns. A single drawing of each portion of the structure identifying locations and sizes of all sleeves and blockouts shall be submitted for review and approval six weeks prior to placing concrete in these structural elements. Penetrations not shown on the approved shop drawings will not be permitted in the field. Penetrations include all pipes, sleeves, conduit, blockouts, elements exceeding 1/3 the slab thickness, and other openings through concrete including slab-on-metal deck. Prior approval must be obtained from engineer for all coring of concrete and shall be reviewed on a case-by-case basis.
2. Shop drawings and calculations for all informational and action submittals as noted in project specifications shall be submitted to the Architect/Engineer for approval prior to fabrication or construction of all structural items including the following: concrete and masonry reinforcement, embedded steel items, structural steel, metal decking, shear stud layout, stairs, pre-engineered wood and pre-engineered cold-formed steel. Approved shop drawings shall be submitted to the local Building Department by the contractor for record only. Allow 2 weeks for review of shop drawings.
3. The general contractor shall submit any substitution request to the Architect/Engineer prior to making any changes. The request shall include all information required for the engineer to fully evaluate the substitution and determine any required compensation for the evaluation.
4. Design, materials, equipment, and products other than those described below or indicated on the drawings may be considered for use, provided prior approval is obtained from the Owner, Architect/Engineer, and the applicable governing code authority.
SPECIAL INSPECTIONS
1. All omissions or conflicts between the various elements of the working drawings and/or specifications shall be brought to the attention of the Architect/Engineer before proceeding with any work so involved.
2. A detail, section, elevation, etc. reference may be indicated only once on a structural construction drawing, but is to be used at all like and similar construction conditions.
3. No modification shall be made to any structural member without the approval of the Architect/Engineer. This also applies to any openings for plumbing, electrical, and mechanical trades.
4. Contractor must check all dimensions, framing conditions, and site conditions before starting work. Architect/Engineer shall be notified immediately of any discrepancies or possible deficiencies.
5. The structural drawings have been completed using the available information regarding existing conditions. The structural engineer has not field verified any existing conditions. It is the responsibility of the General Contractor to field verify the existing conditions and notify the architect and engineer of any discrepancies before proceeding with work.
6. The Contractor shall be responsible for all excavation procedures and protection of adjacent property, structures, utilities, etc. in accordance with all national, state, and local ordinances.
7. Stability of the structural frame during construction is the responsibility of the General Contractor. The structural frame is not complete until all connections to lateral force resisting elements have been made, inspected as required by the building official, and accepted by the engineer. This includes all diaphragm elements such as metal deck, plywood and gypsum board wall sheathing, metal straps, concrete topping, tie rods, and the like. All concrete elements must have reached their required strength. Temporary bracing of the structure during construction should be provided by the General Contractor and their Sub-Contractors as necessary.
8. Do not place backfill against basement walls until basement and first floors are in place or wall has been adequately shored.
Forces due to hydrostatic pressure have not been included in the design of foundation walls.
9. All mechanical and electrical equipment purchases shall be coordinated with the structural drawings by the General Contractor. This includes equipment size, weight, openings, required support, etc. Any discrepancies shall be brought to the architect's and engineer's attention prior to equipment purchase.
10. The contractor shall not stockpile any building materials or equipment in a manner that will exceed the load carrying capacity, cause damage, or create excessive deflection to any structural element. The contractor shall contact the engineer for evaluation of locations where it may be necessary for heavy equipment or building material stockpiles prior to placement of these items on any structural element.
11. For any item that requires a change or correction due to contractor error or deficiency in construction, the contractor shall submit plans, details, and calculations for the proposed solution. These shall be reviewed by the Architect/Engineer prior to completion of the work. Some corrections may require submitted documentation to be stamped and signed by a professional engineer who is registered in the project jurisdiction.
12. Nothing contained within the contract documents shall relieve the general contractor and the subcontractors of:
a. responsibility to determine any aspect of how the work is to be performed
b. dealing with matters of safety of personnel
c. safety of property
d. superintending of the work
e. construction means and methods
CONSTRUCTION
32 (20) 31 (19) 29 (18) 28 (17)
39 (24) 37 (23) 33 (20) 31 (19)
99 (60) 93 (56) 86 (52) 80 (48)
51 (31) 48 (29) 43 (26) 40 (24)
67 (41) 63 (38) 57 (35) 53 (32)
67 (41) 63 (38) 57 (35) 53 (32)
1. Wide flange shapes shall be ASTM A992.
2. Round hollow structural sections shall be ASTM A500 Grade C (46 ksi).
3. Square and rectangular hollow structural sections (HSS) shall be ASTM A500 Grade C (50 ksi).
4. Pipe sections shall be ASTM A53 Grade B (35 ksi).
5. Miscellaneous structural steel such as angles and channels shall be ASTM A36 / ASTM A572-50.
6. Plates shall be ASTM A36 unless noted otherwise. Plates used for any type of moment connection shall be ASTM A572-50.
7. All welding electrodes shall conform to ASTM E70XX. The minimum fillet weld size shall be 3/16", unless noted otherwise.
8. Headed anchor studs shall conform to ASTM A108 (60 ksi).
9. Anchor rods and unfinished rods shall conform to ASTM F1554, Grade 36.
10. Bolted connections are to be of high-strength ASTM A325-N bolts, unless noted otherwise. A minimum of two bolts is required for all beam connections. Minimum required connection capacity is 12 kips LRFD factored load unless noted otherwise.
11. High-strength bolts shall conform to the provisions of the "Specification for Structural Joints Using High-Strength Bolts", latest edition, as approved by the Research Council on Structural Connections.
12. All structural steel exposed to weather shall be hot-dip galvanized, unless noted otherwise. See specifications for additional galvanizing information.
13. All structural steel shall be shop coated with an approved rust inhibitive primer. Do not prime beams that are to receive fireproofing.
STRUCTURAL STEEL
PRODUCTS AND MATERIALS
SHOP DRAWINGS
CONSTRUCTION
1. Shop drawings for all structural steel indicated on the structural drawings shall be submitted for review to the Structural Engineer prior to fabrication.
2. Connections shall be as shown in schedules and sections in the drawings. Any changes to the connections proposed by the contractor shall be submitted with the structural steel shop drawings. This connection submittal shall include calculations stamped and signed by the contractor's engineer.
FABRICATION AND ERECTION
1. All fabrication and erection shall conform to the latest edition of the AISC Manual of Steel Construction.
2. All members are to be erected with natural mill camber or induced camber up, unless noted otherwise on the plans.
3. <For composite steel beam floors only>.