Attachment 27 - HERT 18-9002-Bldg 2113 Result 1.pdf

PDF 10 MB Posted

Attached to
Combined 8 Building Demolition Service Federal contract opportunity
Solicitation number
FA480022Q0004
Issued by
Department of the Air Force Air Combat Command

About this file

This federal contract opportunity solicitation seeks demolition and cleanup services on Joint Base Langley-Eustis in Virginia. The contractor shall demolish eight buildings and perform site cleanup on a previously demolished building. Services include field investigations, transportation of vehicles and equipment, tools, supplies, labor and supervision to demolish the buildings in accordance with attached drawings, specifications and applicable laws and practices. The focus is on safety and customer service. The solicitation was issued by the Department of the Air Force Air Combat Command. Offerors must submit responses by the deadline specified in solicitation number FA480022Q0004 to be considered for this contract to demolish buildings 801, 2731, 2783, 2785, 2794, 2799, 2113 and 2114 on Fort Eustis, Virginia.

View the file

Other files for this federal contract opportunity

Other files attached to Combined 8 Building Demolition Service, newest first.
File Type Posted
Solicitation Amendment FA480022Q00040002 SF 30.pdf PDF
DoD SAFE-5g34EwwAKuKbXx35 (1).zip ZIP file
DoD SAFE-gRkgndrvpUmMkKbG.zip ZIP file
DoD SAFE-ecMNbmrRRJn6c4HW (2).zip ZIP file
DoD SAFE-ecMNbmrRRJn6c4HW (1).zip ZIP file
DoD SAFE-5g34EwwAKuKbXx35.zip ZIP file
Combined 8 building Demo Questions and Answers No. 2.pdf PDF
Resubmit Attachment 20 - 2799 Asbestos Report.pdf PDF
Resubmit Attachment 23-1 -HERT 13-9006 Demolish Bldgs 2731 Result 1.pdf PDF
Attachment 4 - 801 Cover Letter.pdf PDF
Attachment 17 - 2794 Pb Inspection.pdf PDF
Attachment 19 -2799 Hazmat Letter.pdf PDF
Attachment 25 - HERT 13-9006 Demolish Bldgs 2731 Result 3.pdf PDF
2731 Hazmat Letter TCLP.pdf PDF
2794 Hazmat Letter TCLP.pdf PDF
2783 Hazmat Letter TCLP.pdf PDF
HERT 18-9002-Bldgs 2113 Result 3.pdf PDF
2799 Pb Inspection.pdf PDF
2785 Asbestos Report.pdf PDF
2785 Hazmat Letter.pdf PDF
Attachment 18- 2799 Cover Letter.pdf PDF
Attachment 21 - 2799 Pb Inspection.pdf PDF
Attachment 29 HERT 18-9002-Bldgs 2114 Result 1.pdf PDF
2785 Hazmat Letter TCLP.pdf PDF
2799 Hazmat Letter TCLP.pdf PDF
HERT 18-9002-Bldgs 2114 Result 1.pdf PDF
HERT 18-9002-Bldgs 2114 Result 2.pdf PDF
HERT 13-9006 Demolish Bldgs 2731 Result 2.pdf PDF
2799 Cover Letter.pdf PDF
2794 Hazmat Letter.pdf PDF
2785 Pb Inspection.pdf PDF
Attachment 1 - PWS Combined 8 Bldg Demo 13 Dec 21.pdf PDF
Attachment 5 - 801 Hazmat Letter.pdf PDF
Attachment 6 - 801 Pb Inspection.pdf PDF
Attachment 8 -2783 Cover Letter.pdf PDF
Attachment 22- TCLP Bldg 2114.pdf PDF
Attachment 23 - HERT 13-9006 Demolish Bldgs 2731 Result 1.pdf PDF
Attachment 24 - HERT 13-9006 Demolish Bldgs 2731 Result 2.pdf PDF
Attachment 31 - HERT 18-9002-Bldgs 2114 Result 3.pdf PDF
Bldg 2113 TCLP.pdf PDF
Bldg 2114 TCLP.pdf PDF
HERT 18-9002-Bldg 2113 Result 1.pdf PDF
TCLP Bldg 2114.pdf PDF
2799 Hazmat Letter.pdf PDF
2794 Asbestos Report.pdf PDF
2794 Cover Letter.pdf PDF
2785 Cover Letter.pdf PDF
Attachment 26 - HERT 18-9002-Bldg 2113 part 2.pdf PDF
Solicitation - FA480022Q0004.pdf PDF
Attachment 2 - Wage Determination 2015-4341 Rev19 27 Dec2021.pdf PDF
Show all 50

Combined 8 Building Demolition Service has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Comments

1. The following materials tested positive for asbestos:

Upper Roof Membrane (Less than 1%)

Upper Roof Vent

Upper Roof Curb Flashing

Upper Roof Gravel Stop

Lower Roof Membrane (Less than 1%)

Lower Roof Vent

Lower Roof Curb Flashing

Lower Roof Parapet Flashing

Lower Roof Gravel Stop

2. Materials having less than 1% asbestos by layer are not considered to be Asbestos

Containing Materials (ACM) under the EPA. These materials may be discarded as general construction debris. Materials having less than 1% asbestos do have requirements under OSHA for training, prompt cleanup, wet methods, and HEPA vacuum use.

3. Asbestos might be found within walls, ceiling and or pipe chases during the renovation or demolition of the building. If any suspect materials are found they should be treated as asbestos or tested for asbestos.

ASBESTOS CONTAINING MATERIALS QUANTITY

Upper Roof Vent 10

Upper Roof Curb Flashing 120 linear ft.

Upper Roof Gravel Stop 420 linear ft.

Lower Roof Vent 1

Lower Roof Curb Flashing 12 sq. ft.

Lower Roof Parapet Flashing 40 linear ft.

Lower Roof Gravel Stop 90 linear ft.

Fort Eustis Civil Engineering Flight - Asbestos Report MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia

SECTION 3

General Legend and Notes

GENERAL LEGEND

O - Sample number/location - non-asbestos

- Sample number/location - contains asbestos

GENERAL NOTES

1. The EPA definition of a friable material is one that contains more than 1% asbestos by weight and can be crumbled, pulverized or reduced to a powder by hand pressure when dry, or which under normal use or maintenance emits or can be expected to emit asbestos fibers into the air.

2. All quantities are approximate.

3. Sketches are not to scale.

SECTION 4

Asbestos Containing Material Sketches

Asbestos Positive Materials Building 2113, Roof Fort Eustis, Virginia

Upper and Lower Roofs:

Vents

Curb Flashings

Parapet Flashings (Lower Only)

Gravel Stops

MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia Page 17 of 56

SECTION 5

Survey Sample Location Sketches

Asbestos Sample Locations Building 2113, Basement

Fort Eustis, Virginia

Building 2113, 1st Floor

Fort Eustis, Virginia

MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia Page 20 of 56

Building 2113, 2nd Floor Fort Eustis, Virginia

28 31

35 40

MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia Page 21 of 56

Building 2113, 3rd Floor

Fort Eustis, Virginia

MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia Page 22 of 56

Building 2113, Roof Fort Eustis, Virginia

MCS Job #19-107S - Fort Eustis Building #2113, Fort Eustis, Virginia Page 23 of 56

SECTION 6

Reports of Analysis

HERT 18-9002-Bldgs 2113,2114,2116
19-107S Ft. Eustis Building 2113, Asbestos Report -signed
Ft. Eustis Building 2113 PM.pdf
Blank Page
Ft. Eustis Building 2113 Sample Locations.pdf
Blank Page
Blank Page
19-107S Ft. Eustis Building 2113 PM.pdf
Blank Page

File details come from the government source that posted it. Updated .