Attachment 2 - Volume 2.pdf
PDF 225 KB Posted
- Solicitation number
- 19GE5025Q0138
About this file
This is a Volume 2: Technical Capability document for Solicitation 19GE5025Q0138, seeking a Biosafety Cabinet for AFRIMS (Armed Forces Research Institute of Medical Sciences) in Thailand. The solicitation requires a Class II Type A2 SterilGARD® biosafety cabinet with specific technical specifications, including HEPA filtration with ≥99.99% efficiency, integrated airflow monitoring with alarms, UV light for decontamination, and compliance with NSF/ANSI 49 standards. The cabinet must provide protection for personnel, product, and environment at BSL-2 and BSL-3 laboratory levels, feature a stainless steel work surface, and operate with a low noise level.
The document is a response template requiring offerors to complete a compliance confirmation table, provide company information, and certify the accuracy of their submission. Vendors must specify warranty terms, delivery schedule, and lead time, with a warning that failure to provide complete information may result in exclusion from consideration. The solicitation emphasizes technical compliance, requiring detailed confirmation of each specified technical requirement through a yes/no checkbox system and space for remarks or model references.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Solicitation 19GE5025Q0138 AFRIMS Thailand - Biosafety Cabinet
VOLUME 2: TECHNICAL CAPABILITY
The offer shall set forth current, accurate, and complete information as required by this solicitation. The offer shall be prepared as follows:
PART I: OFFEROR INFORMATION
General information about the offeror, including legal entity name, address, and Unique Entity Identifier (UEI).
Company Name
Company Address
Unique Entity Identifier (UEI)
PART II: COMPLIANCE CONFIRMATION TABLE – BIOSAFETY CABINET CLASS II TYPE A2
# Requirement Meets Requirement (Yes/No)
Remarks / Model Reference
Offered unit is Biosafety Cabinet Class ll Type A2 SterilGARD® as specified in solicitation. ☐ Yes ☐ No
Fully compliant with NSF/ANSI 49 standards for Class II Type A2 biosafety cabinets. ☐ Yes ☐ No
Provides protection for personnel, product, and environment at BSL-2 and BSL-3 laboratory levels. ☐ Yes ☐ No
Equipped with HEPA filtration (≥99.99% efficiency for
0.3 micron particles) for both downflow and exhaust air.
☐ Yes ☐ No
Includes integrated airflow monitoring with visual and audible alarms. ☐ Yes ☐ No
6 Includes UV light for work area decontamination. ☐ Yes ☐ No
Sash window with auto-stop at safe operating height. ☐ Yes ☐ No
Stainless steel work surface and interior, corrosion-resistant construction. ☐ Yes ☐ No
Operates at low noise level (≤ ___ dB; as per manufacturer’s specs). ☐ Yes ☐ No
Solicitation 19GE5025Q0138 AFRIMS Thailand - Biosafety Cabinet
# Requirement Meets Requirement (Yes/No)
Remarks / Model Reference
Power supply: 220V, 50Hz, plug type - as original by factory. ☐ Yes ☐ No
Cabinet dimensions as specified in manufacturer’s standard datasheet. ☐ Yes ☐ No
Includes all factory-standard accessories and safety features. ☐ Yes ☐ No
PART III: WARRANTY AND DELIVERY TERMS
State the proposed warranty terms and delivery schedule, including warranty coverage period and scope, delivery time from the date of acceptance of purchase order (in calendar days), and method of shipment and any related conditions.
Warranty Terms
Delivery Terms
Delivery Lead Time
Failure to furnish and deliver all requested information in accordance with these instructions may result in exclusion from further consideration pursuant to FAR 52.212-1(b)(11). The penalty for making false statements is prescribed in 18 USC 1001.
CERTIFICATION:
I hereby certify that the responses to the above representations, certifications, and other statements are accurate and complete.
Offeror’s signature Date
Print Name
{END OF VOLUME 2}
File details come from the government source that posted it. Updated .