Attachment 2 SOW_SalientCharact_TinyHomes.pdf

PDF 133 KB Posted

Attached to
Tiny Home on Wheels - Payette National Forest Federal contract opportunity
Solicitation number
1282B124Q0056
Issued by
Department of Agriculture Forest Service

About this file

This document is a Statement of Work (SOW) and Salient Characteristics for a Tiny Home Procurement by the USDA Forest Service, R4. The SOW specifies the requirements for the supply and delivery of one or more tiny home housing units, including construction details, materials, framing, and delivery locations. The base bid is for one unit to be delivered to McCall, ID, and an optional bid item is for a second unit to be delivered to Cascade, ID. The tiny homes must meet specific size, layout, and feature requirements, as well as comply with referenced building codes and standards. The document also outlines the required deliverables, such as design plans and product data. This SOW is associated with a Request for Quotes (RFQ) Solicitation for the procurement of the tiny homes, with quotes due on May 28, 2024.

View the file

Other files for this federal contract opportunity

Other files attached to Tiny Home on Wheels - Payette National Forest, newest first.
File Type Posted
SF 30_1282B124Q0056_002.pdf PDF
Attachment 4 Q and A sheet.pdf PDF
Attachment 3 Update SalientCharact_TinyHomesProcurement_6.3.24.pdf PDF
SF 30_1282B124Q0056_001.pdf PDF
1449_1282B124Q0056.pdf PDF
Attachment 1 Schedule of Items.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Work/Salient Characteristics

TINY HOME PROCUREMENT

May, 2024

USDA FOREST SERVICE, R4

PART 1 - GENERAL

1.1 SUMMARY

A. This item shall consist of the supply and delivery of housing unit “Tiny home”.

1. Base Bid Item (1 unit)

a. Housing unit, min 230 sq ft., max 240 sq ft. delivered to 500 N Mission St.

McCall, ID 83638

2. Optional Bid Item (1 unit)

a. Housing unit, min 230 sq ft., max 240 sq ft. delivered to 304 Warm Lake Hwy. Cascade, ID 83611

B. The units shall be designed, constructed, and installed in accordance with the Codes reference in paragraph 1.3, below.

1.2 BASIS OF DESIGN

A. Refer to the Salient Characteristics in Part 2.

1.3 DELIVERABLES

A. Tiny Home Unit

B. Unit final plans including design blueprint for trailer and connections and electrical layout

C. Manufacturer’s product data

D. Manuals for all installed appliances and specific materials

1.4 REFERENCE SPECIFICATIONS

A. The publications listed below form a part of this specification to the extent referenced.

The publications are referred to in the text by the basic designation only.

2021 International Building Code 2021 International Residential Code 2021 International Plumbing Code 2021 International Mechanical Code 2021 International Fuel Gas Code

2021 International Energy Conservation Code 2021 International Urban-Wildlife Interface Code 2023 National Electrical Code 2022 National Fire Protection Association Standards 13R and 13D.

2004 Americans with Disabilities Act/Architectural Barriers Act Guidelines

(ADA/ABAG)

PART 2 - SALIENT CHARACTERISTICS

2.1 HOUSING UNITS CONSTRUCTION LAYOUT AND FEATURES

A. Housing Unit Summary:

1. 8’6” foot wide and with min of 9’ tall.

2. Between 240-230 sq ft. w/ possible loft spaces.

3. Operational kitchen with refrigerator, stove, electric fan/vent, microwave and sink.

4. Sleeping area on main floor with room for a full-size bed.

5. Operational bathroom with toilet, sink, and shower.

6. Constructed for 4 seasons, heating and AC (min 15 SEER mini-split unit).

7. Include connections for sewer (4-inch), electric tie-in (with appropriate circuit breakers), and water supply (1/2-inch).

8. Accessible steps to entrance with handrail

9. Appropriate tie-downs for weather and vinyl skirting to be installed on the housing unit.

10. The government will be responsible for all utility connections.

11. Minimum one (1) year complete warranty, and additional warranties to industry standard on HVAC, appliances and other materials.

B. Rodent Proofing

1. All precautions should be taken during construction so that the units will remain rodent proof during their life span.

C. Interior Materials

1. Inside walls at a minimum ½” gypsum board (water resistant gyp-board in wet areas) taped, textured and painted.

2. Interior walls must be constructed to allow for, and support moving the unit from location to location as required with minimal damage.

3. Wood patterned vinyl adhesive strip flooring at a minimum.

D. Exterior Materials

1. The exterior shall be made of wood, fiber cement, aluminum and/or steel.

2. Insulated exterior door

3. The roofing system shall consist of a standing seam metal construction.

E. Finish Quality

1. Construction will be typical of “builders grade” suitable for a government facility.

2. The exterior should have suitable windows (min 2-pane) and egresses of a typical home/cabin.

3. Interiors shall have adequate lighting and features found in a typical small home.

F. Meet RVIA NFPA 1192 Standards (also known as ANSI 119.2) with the following exceptions:

1. The definition of Recreational Vehicle does not apply and is replaced with the definition of a Tiny House On Wheels (as stated above).

2. Wherever "RV" or "recreational vehicle" appear, the acronym "THOW" or phrase "tiny house on wheels" is to be substituted.

3. A secondary means of escape (egress window) is not required to be labeled, and there is no requirement as to the type or color of its handle.

4. Warning labels are not required. However, it is recommended that NFPA 1192 requirements for warning labels be met for any THOW that is intended for sale.

5. Similarly, an owner's manual is not required but is recommended for any THOW that is intended for sale or rent.

G. Be secured to a trailer that is adequate for the weight of the tiny house, its furnishings and occupants. The trailer must meet Department of Transportation (DOT) guidelines of the state in which the THOW is registered. The frame must be securely fastened to the trailer as specified below in the framing guidelines.

H. Use quality materials.

1. New structural components (steel, lumber, plywood/OSB, ties, and fasteners) should meet the International Building Code, Residential Code.

2. Fasteners must be corrosion resistant at structural tie-points and where the house attaches to the trailer frame or foundation. This is done so that a future water leak, or the actions of chemicals in treated lumber, do not damage structurally important fasteners. The two most common types of corrosion-resistant fasteners are 1) hot-dip galvanized nails and screws, and 2) coated exterior screws.

3. For engineered straps, hurricane clips, tension ties, joist hangers, and header hangers, use the fasteners recommended by the manufacturer. Only use the nails and screws designed for the engineered system. "Tico" nails (10d 1.5-inch) are the most common. SD series screws can be used for anchoring straps and tie-downs.

4. For the interior "envelope" (enclosed space) of the house, materials (plastics, glues, insulation, paints, and finishes) must be labeled by the manufacturer as safe for interior use or known to be chemically safe for interior use.

I. Framing

1. Welded Steel frames: Steel frames must be secured to the trailer by welding to the trailer frame.

2. Wood frames: Wood frames must meet the guidelines for earthquake and high-wind loading in the International Residential Code for One- and Two-Family Dwellings, section R602. Proper bridging supports and frame supports are required

3. Frame walls with graded 2x4 lumber and either 16d hot-galvanized ring shank nails or structural screws (extra strong, thin, sharp screws that meet stringent engineering standards. Made by GRK, Spax and FastenMaster), maximum 24" on center (recommended: 16" on center ).

4. Use appropriate headers and frames for windows, doors, and other openings. While building code allows as little as 16% of a wall to be braced (e.g., a 16 ft wall only needs 2' 7" of bracing), THOWs are subject to sustained wind loads and minor "seismic" loads. To add windows without increasing the need for bracing, you may use small windows that do not span more than one stud bay (a 14.5" rough opening for traditional framing). If open spaces make up more than 25% of a wall, crossbeams may be required for additional support. Consult a structural engineer

5. Double top plates are recommended.

6. Sheath walls with minimum 3/8" CDX plywood or OSB (1/2" recommended), fastened with ring shank nails or structural screws, 6" on-center along the edges of the panel, and 12" on-center elsewhere. Use of adhesive on the fastener locations is recommended.

7. 7.b.5 Sheath roof with minimum 1/2" CDX plywood or OSB (5/8" recommended), fastened with ring shank nails or structural screws, 6" on-center along the edges of the panel, and 12" on-center elsewhere.

8. Use adhesive on all sheathing.

9. Tie the roof to the walls with hurricane straps, and 10d nails.

10. Tie the walls to the foundation/trailer frame with one of these methods:

a. hurricane tie-down brackets and minimum 3/8" galvanized bolts.

b. a threaded rod and turnbuckles from trailer frame to top of wall plate, then hurricane roof ties to tie studs, plates, and roof trusses.

c. another method that is detailed in the THOW plans and that has been reviewed and approved by a structural engineer.

11. For floor joists, 2x4 lumber is acceptable; 2x8 can provide greater R value.

12. When building on a trailer frame, the steel frame and crossmembers may be your floor frame and structure. You may place the subfloor directly on trailer frame, fastening every 12" with #12 coated or galvanized self tapping metal screws. Keep in mind, this method is not in the International Residential Code. If your trailer does not have sufficient crossmembers, you may build a separate floor structure (a box floor) and bolt it to the trailer rails.

13. SIPs: If Structured Insulated Panels (SIPs) are used, they must be installed according to the manufacturer's guidelines, and secured to the trailer in a similar manner as a wood frame.

14. Windows & other exterior glass must be tempered, laminated, or secured with shutters during tow.

15. Roofs: Minimum roof slope (measured in rise over 12" run) must meet roofing material requirements. Roof must slope away from main door. Roof loading must meet local building code requirements.

2.2 DELIVERY

1. Base Bid Item (1 unit)

a. Housing unit delivered to 500 N Mission St. McCall, ID 83638

2. Optional Bid Item (1 unit)

a. Housing unit delivered to 304 Warm Lake Hwy. Cascade, ID 83611

1. Base Bid Item (1 unit)
2. Optional Bid Item (1 unit)
1. 8’6” foot wide and with min of 9’ tall.
2. Between 240-230 sq ft. w/ possible loft spaces.
3. Operational kitchen with refrigerator, stove, electric fan/vent, microwave and sink.
4. Sleeping area on main floor with room for a full-size bed.
5. Operational bathroom with toilet, sink, and shower.
6. Constructed for 4 seasons, heating and AC (min 15 SEER mini-split unit).
7. Include connections for sewer (4-inch), electric tie-in (with appropriate circuit breakers), and water supply (1/2-inch).
8. Accessible steps to entrance with handrail
9. Appropriate tie-downs for weather and vinyl skirting to be installed on the housing unit.
10. The government will be responsible for all utility connections.
11. Minimum one (1) year complete warranty, and additional warranties to industry standard on HVAC, appliances and other materials.
1. All precautions should be taken during construction so that the units will remain rodent proof during their life span.
1. Inside walls at a minimum ½” gypsum board (water resistant gyp-board in wet areas) taped, textured and painted.
2. Interior walls must be constructed to allow for, and support moving the unit from location to location as required with minimal damage.
3. Wood patterned vinyl adhesive strip flooring at a minimum.
1. The exterior shall be made of wood, fiber cement, aluminum and/or steel.
2. Insulated exterior door
3. The roofing system shall consist of a standing seam metal construction.
1. Construction will be typical of “builders grade” suitable for a government facility.
2. The exterior should have suitable windows (min 2-pane) and egresses of a typical home/cabin.
3. Interiors shall have adequate lighting and features found in a typical small home.
1. The definition of Recreational Vehicle does not apply and is replaced with the definition of a Tiny House On Wheels (as stated above).
2. Wherever "RV" or "recreational vehicle" appear, the acronym "THOW" or phrase "tiny house on wheels" is to be substituted.
3. A secondary means of escape (egress window) is not required to be labeled, and there is no requirement as to the type or color of its handle.
4. Warning labels are not required. However, it is recommended that NFPA 1192 requirements for warning labels be met for any THOW that is intended for sale.
5. Similarly, an owner's manual is not required but is recommended for any THOW that is intended for sale or rent.
1. New structural components (steel, lumber, plywood/OSB, ties, and fasteners) should meet the International Building Code, Residential Code.
2. Fasteners must be corrosion resistant at structural tie-points and where the house attaches to the trailer frame or foundation. This is done so that a future water leak, or the actions of chemicals in treated lumber, do not damage structurally impo...
3. For engineered straps, hurricane clips, tension ties, joist hangers, and header hangers, use the fasteners recommended by the manufacturer. Only use the nails and screws designed for the engineered system. "Tico" nails (10d 1.5-inch) are the most c...
4. For the interior "envelope" (enclosed space) of the house, materials (plastics, glues, insulation, paints, and finishes) must be labeled by the manufacturer as safe for interior use or known to be chemically safe for interior use.
1. Welded Steel frames: Steel frames must be secured to the trailer by welding to the trailer frame.
2. Wood frames: Wood frames must meet the guidelines for earthquake and high-wind loading in the International Residential Code for One- and Two-Family Dwellings, section R602. Proper bridging supports and frame supports are required
3. Frame walls with graded 2x4 lumber and either 16d hot-galvanized ring shank nails or structural screws (extra strong, thin, sharp screws that meet stringent engineering standards. Made by GRK, Spax and FastenMaster), maximum 24" on center (recommen...
4. Use appropriate headers and frames for windows, doors, and other openings. While building code allows as little as 16% of a wall to be braced (e.g., a 16 ft wall only needs 2' 7" of bracing), THOWs are subject to sustained wind loads and minor "sei...
5. Double top plates are recommended.
6. Sheath walls with minimum 3/8" CDX plywood or OSB (1/2" recommended), fastened with ring shank nails or structural screws, 6" on-center along the edges of the panel, and 12" on-center elsewhere. Use of adhesive on the fastener locations is recommen...
7. 7.b.5 Sheath roof with minimum 1/2" CDX plywood or OSB (5/8" recommended), fastened with ring shank nails or structural screws, 6" on-center along the edges of the panel, and 12" on-center elsewhere.
8. Use adhesive on all sheathing.
9. Tie the roof to the walls with hurricane straps, and 10d nails.
10. Tie the walls to the foundation/trailer frame with one of these methods:
11. For floor joists, 2x4 lumber is acceptable; 2x8 can provide greater R value.
12. When building on a trailer frame, the steel frame and crossmembers may be your floor frame and structure. You may place the subfloor directly on trailer frame, fastening every 12" with #12 coated or galvanized self tapping metal screws. Keep in mi...
13. SIPs: If Structured Insulated Panels (SIPs) are used, they must be installed according to the manufacturer's guidelines, and secured to the trailer in a similar manner as a wood frame.
14. Windows & other exterior glass must be tempered, laminated, or secured with shutters during tow.
15. Roofs: Minimum roof slope (measured in rise over 12" run) must meet roofing material requirements. Roof must slope away from main door. Roof loading must meet local building code requirements.