This document is an Attachment 2 - Price Schedule that appears to be part of a federal contract opportunity. The contract opportunity is for the procurement of industrial hygiene equipment such as noise dosimeters, sound level meters, air quality meters, calibration equipment, ventilation smoke tubes, video borescopes, and various air sampling supplies. The solicitation is a combined synopsis/solicitation for commercial items issued by the Defense Logistics Agency as a 100% small business set-aside. The request for quotes has a solicitation number of SP4705-24-Q-0225 and the equipment is to be delivered to various locations. The price schedule provides detailed specifications, make/model information, and pricing for the required equipment and supplies. This appears to be a comprehensive list of products needed to support industrial hygiene monitoring and analysis requirements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ATTACHMENT 2 – PRICE SCHEDULE
Contract Line Item Number
Item Item Specifications Make and Models Item Requirements Unit of Issue
Quantity Unit Price
Total Amount
Ship to Address
0001 Noise Dosimeter(s)
Single-unit Dosimeter with Microphone A-weighted Dynamic Range 94 dB Peak Range 78 – 143 dB Peak, C-weighted Peak Weightings A, C, Z RMS Weightings A, C, Z Time Weightings Slow, Fast, Impulse Frequency Range 20 Hz to 10 kHz Data Windscreen;
USB Cable;
Power Cord;
Calibration Adapter;
Unit Carry Case 2-year warranty
TSI® Edge 7 Single Dosimeter
EG7
Or
Larson Davis MODEL Spartan
Standards ANSI S1.25-1991 (R2017), IEC 61252 Ed. 1.2 Linear Operating Range 52 – 140 dB rms Logging Selectable 1 second- or 1-minute samples Logged data LAeq, LCeq, LCpeak, LZpeak, LASmax, LAFmax, ACGIH TWA 3 dB Exchange, OSHA TWA 5dB Exchange
EA 10
8725 John J.
Kingman Ft. Belvoir, VA 22060
0002 Sound Level Meter (SLM)
Type II Sound Level Meter (SLM) with:
Exchange rates of 3,4,5,6 dB TWA, Lavg, Lmax Lpeak Impluse, Dose 1/1 and 1/3 Octave 40 to 140 dB Calibrator adapter
TSI ® Sound Pro
SE DL
SP-SE-2-1/3
Or
Larson Davis® Spartan Series 821H
ANSI S1.4-1985
(R2001), S1.43- 1997 (R2002 /S1.25-1991 (R2007), S1.11- 2004
ANSI A10.46-2007
EA 2 8725 John J.
Kingman Ft. Belvoir, VA 22060
0003 Noise Calibrator
Calibrator adapter for 1/4 inch microphone Output: 114 dB, 1000 Hz, portable self-contained field calibrator
Larson Davis
CAL150
or
TSI AC3 or equivalent
ANSI S1.40
EA 3
Ft. Belvoir, VA 22060
Line Item Number
Item Item Specifications Make and Models Item Requirements Unit of Issue
Quantity Unit Price
Total Amount
Ship to Address
0004 Indoor Air Quality (IAQ) Meter
Single unit that measures:
6 different types of gases, PM2.5 and PM10 mass concentrations and particle counts:
Temperature:
Relative humidity: and barometric pressure Portable Stand
TSI Q-Trak XP IAQ monitor model 7585
EVM-7
Or equivalent
Quest EVM-7
SENSORS:
Carbon Dioxide sensor (0-5000 ppm) Carbon Monoxide
Sensor (0-50 ppm) Nitrogen Dioxide sensor Nitrogen Oxide
Sensors Hydrogen sulfide sensor TVOC sensor –
Low TVOC sensor -high
EA 2 8725 John J.
Kingman Ft. Belvoir, VA 22060
0005 Portable personal air sampler pumps kit
A kit of five (5) Personal air samplers
Flow Range meets Constant flow 20 – 5,100 cc/min. without external adaptors Constant pressure 1 – 5,100 cc/min without external adaptors Constant Flow or High and Low Flow Constant Pressure Run Time 8-hour minimum Temperature Ranges Operating 32°F to 113°F (0°C to 45°C) Storage -4°F to 113°F (-20°C to 45°C) Charging 41°F to 104°F (5°C to 40°C)
GilAir Plus Sampling Pump
910-0904-US-R
or
SKC AirChek Essential 5-pack High/Low Flow Pump Kit
ISO 13137:2013
Compliant
Intrinsic Safety US/Canada NRTL
(FM):
Class I, Div 1 Groups A, B, C, D, E, F, and G; Class II, Div 1 Zone 0; Class III, T4
ATEX/IEC:
Ex – II 1 G; Ex ia IIC T4
CE
Applicable Directives:
ATEX 94/9/EC;
EMC 2004/108/EC
(RFI); LVD
EA 2 8725 John J.
Kingman
Number
Item Item Specifications Make and Models Item Requirements Unit of Issue
Quantity Unit Price
Total Amount
Ship to Address
Humidity Ranges Operating 5-95 %RH, non-condensing Storage 5-98 %RH, non-condensing Display Flow rate, sample time, and sample volume in actual conditions Controls Indicators Green and Red LED’s Dimensions no more than
4.3 x 2.4 x 2.4 inches (10.9 x
6.1 x 6.1 centimeters) Weight 20.5 ounce (581 grams) Warranty must be 2 years from original shipment Rechargeable nickel-metal hydride (NiMH) battery pack, or optional alkaline battery pack, or DC power.
Battery Level Indicator On-screen icon displays battery level.
Charging Time less than
3.5 hours.
Tygon tubing 1/inch
2006/95/EC; RoHS Compliant
0006 Primary Calibrator, low, standard and high volume
Primary Standard (NIOSH) Dry Cell Calibrator –with Stable Back Pressure with (3) dry flow cells for:
Low: 5-450 cc/min, Gilian® Gilibrator®
910-1701-US-R
Or
ISO 13137:2013
Compliant
Intrinsic Safety US/Canada NRTL
(FM):
Class I, Div 1 Groups
EA 2 8725 John J.
Kingman
Number
Item Item Specifications Make and Models Item Requirements Unit of Issue
Quantity Unit Price
Total Amount
Ship to Address
Standard: 50-5000 cc/min, High: 1 LPM-30 LPM)
Bios Drycell Defender
A, B, C, D, E, F, and G; Class II, Div 1 Zone 0; Class III, T4
0007 Micromanom eter
Micromanometer Unit that measures
Pressure, velocity and flow o Auto-zeroing pressure sensor Automatic density correction Duct traverse Pitot, air flow (straight pitot), Temperature /relative humidity, velocity matrix, or thermoanemometer probes
TSI EBT 730 Alnor Micromanometer
EBT 730
Or equivalent
NIST-traceable calibration certificate
EA 1 8725 John J.
Kingman Ft. Belvoir, VA 22060
0008 Light meter Light meter measures Fluorescent Halogen Lamps Incandescent
LED
Metal Halide Sodium Up to 99,990 footcandles
9.999 fc ±3%
0.001 fc 36 in Coiled Cable Built-In Stand Carrying Case Light Sensor Protective Cover Protective Holster
Extech
EA-30
EA 2
Number
Item Item Specifications Make and Models Item Requirements Unit of Issue
Quantity Unit Price
Total Amount
Ship to Address
0009 Calibration
(8) Gases Kit
Span Gas for Carbon Dioxide (CO2) Calibration Gas for Calibration CO2 Monitor Span Gas for Carbon Monoxide (CO) calibration CO Gas for
Span Gas Calibration Volatile Organic Compounds (VOC) – Isobutylene
Span Gas Calibration Hydrogen Sulfide
Nitric Oxide
Nitrogen Dioxide Span Gas – Zero Span Gas r
Span Gas for CO2 1000 ppm 103 Liters
Span Gas for CO 50 ppm 103-Liters
Span Gas for (VOC) - Isobutylene
Low - 20 ppm 103 Liters High- 200 ppm 103 Liters
Span Gas Hydrogen Sulfide 50 ppm 103 Liters
Span Gas Nitric Oxide 20 ppm 103 Liters
Span Gas Nitrogen Dioxide 20 ppm 103 Liters
Span Gas – Zero Air – 103 Liters
EA 2 of each of 8 types equals 16 bottles
Ship one kit of the (8) calibration gases to:
Mannheimer Strasse Kleber Kaserne Bldg 3209 Rm 67657 Kaiserslautern
Ship one kit of
(8) calibration gases to:
Defense Logistics Agency Indo- Pacific Industrial Hygienist 1025 Quincy Avenue, Suite #3000
Number
Item Item Specifications Make and Models Item Requirements Unit of Issue
Quantity Unit Price
Total Amount
Ship to Address
Joint Base Pearl Harbor Hickam, HI 96860
0010 Ventilation Smoke tubes
Tube Kits Allows for controlled generation of visible smoke Determines velocity and flow patterns of heating, ventilating and air-conditioning systems Available with glass or plastic tubes with break-off tips
MSA™ Ventilation Smoke 458481
NA EA 2 8725 John J.
Kingman Ft. Belvoir, VA 22060
0011 Articulating Video boroscope
Articulation video boroscope color monitor Less than 1.5 “ pan and tilt color camera head 25’ push rod 0.33×0.22 in diameter 1 anti-slide mat USB charger and cable Hard-shell plastic carrying case Full Manufacturer warranty
Less than weight: 2 lbs.
Power supply: USB C 5 V / 3 A
Power supply: 3.7 V, 11.4 Ah rechargeable Li-Ion battery
Olympus IPLEX GAir
Or
Wohler Articulating Video boroscope – VIS 700 – 7082
Operating temperature: 32 – 104 °F
Protection:
Waterproof to IP 67 (up to 40 ft. depth for 30 mins.)
Power supply: 3.7 V rechargeable Li-Ion battery
Operating temperature: 0 – 104 degrees F
EA 1 8725 John J.
Kingman
Number
Item Item Specifications Make and Models Item Requirements Unit of Issue
Quantity Unit Price
Total Amount
Ship to Address
Battery operating time: 4 h (battery status in display)
0012 Air Sampling tubing
Tygon Tubing, 1/4-inch ID x 3/8-inch OD, 10 feet Overview
200484 EA 2 8725 John J.
Kingman Ft. Belvoir, VA 22060
0013 Low flow sampling tubing kit
Low Flow Adapter Kit, 5 to 500 ml/min Overview
EA 5 8725 John J.
Kingman Ft. Belvoir, VA 22060
0014 Air sampling inhalable samplers
IOM Inhalable Samplers and Cassettes, Plastic Overview
385-0095-01 EA 10 8725 John J.
Kingman Ft. Belvoir, VA
TOTAL $