This Performance Work Statement (PWS) details the requirements for replacing roof-mounted air conditioner units for four vehicles at Barksdale Air Force Base. The replacement units must meet specific technical specifications, including voltage limits of 24V, maximum length of 22.5", minimum air flow of 1500 CFM, cooling capability of 71.76 sq ft, and capacity not exceeding 24,000 BTU/Hr. The units are critical for protecting personnel from extreme temperatures during aircraft launches and maintenance, with ambient temperatures potentially reaching 100 degrees.
The PWS outlines comprehensive requirements for the new A/C units, including a minimum of 8 hours continuous runtime, an OEM service employee within 50 miles of the base, factory direct service capabilities, and a 24-month or 1,500-hour warranty. The contractor must be HVAC certified, provide all labor and materials for removal and installation of new units, and coordinate with the 20 BGS Vehicle NCO for scheduling. The procurement is set aside for small disadvantaged businesses registered in Louisiana, with a size standard of 1,250 employees, and is part of a solicitation (FA460825QS025) issued by the Department of the Air Force Global Strike Command.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Performance Work Statement (30 April 2025) for
Installation of Vehicle Roof Mounted Air Conditioner Units on Reg. Numbers:
09B02593 / 03B02225 / 08B03957 / 08B03964
Introduction:
This Performance Work Statement (PWS) outlines the requirements for the replacement of the current roof-mounted air conditioners unit installed on the four vehicles listed above that are currently non-operational. They are utilized to eliminate personnel’s prolonged exposure (eight+ hours) to extreme temperatures during aircraft launches and other mission critical maintenance actions. These temperatures normally average around 90 degrees with the potential to exceed 100 degrees. This could lead to dehydration, heat exhaustion, heat stroke, or even death of personnel.
Requirements:
The AC units must meet the following specifications:
o Voltage not to exceed 24V o Length not to exceed 22.5" o Air Flow at least: 1500 CFM o Must have 71.76 Sq ft of cooling capability o Capacity: not to exceed 24,000 BTU/Hr (6,048 kcal/h) o Current Draw not to exceed: 12 amps @ 13.6 VDC (includes 4 amps for A/C clutch) 6 amps @ 27.2 VDC (includes 2 amps for A/C clutch) o Condenser Coil: The coil is aluminum fin and copper tube construction, this material selection, which includes a tube of .022" (6 cm) wall thickness, results in an effective, lightweight rugged coil.
o Motor: must be sealed and weather resistant o Mount Type: Roof Mount o Refrigerant Type: R12/R134a
FA460825QS025
Attachment 2 - Performance Work Statement
Runtime o Minimum of 8 hours of continuous runtime
Service and maintenance o Must have an OEM (original equipment manufacturer) service employee within 50 miles of Barksdale, AFB.
o Must be able to provide Factory direct service for troubleshooting and maintenance outside of end users ability o Easy maintenance with built-In maintenance diagnostics o High visibility Easy Identifiable required maintenance touch points o Full itemized parts listing and manual.
Paper, digital or DVD acceptable.
Manual must include:
Suggested maintenance intervals.
How to guide to perform basic maintenance.
Detailed parts breakdown of entire unit assembly and sub assembly.
Warranty:
o Factory parts Warranty 24 Months or 1,500 hours (whichever comes first)
REMOVAL/INSTALLATION OF OLD VEHICLE ROOF MOUNTED AIR CONDITIONER UNITS
Contractor shall provide labor, tools, and material to facilitate the removal of all preexisting units.
The new systems will include new A/C units, Freon, and any new hoses or lines required for the installation of the four new A/C units.
This proposal is for each of the four vehicles to receive their new units individually due to the necessity and limited number of vehicles on hand to meet mission requirements.
The quote accompanying this proposal includes parts, labor, shop supplies, Haz. Waste, and freight fees.
General Requirements:
1. All equipment, supplies and materials provided / installed shall be new and not refurbished.
2. Inspections / Acceptance checks of completed work shall be performed by 2 LRS, Vehicle Maintenance section and will be based on their quality control criteria.
3. The contractor will be responsible for and incur all labor and material costs required to repair any damages to government vehicles that may occur due to negligence during this contract
4. The Contractor must be HVAC certified
FA460825QS025
Scheduling:
1. Contractor shall coordinate with the 20 BGS VNCO for vehicle availability.
2. The contractor is responsible for contacting the VNCO upon replacement completion for vehicle pick up.